Ahmed, S.F. ; Khan, M.M.K. ; Amanullah, M.T.O. A parametric analysis of the cooling performance of vertical earth-air heat exchanger in a subtropical climate. 2021 Renew. Energy. 172 350-367
- Ahmed, S.F. ; Khan, M.M.K. ; Amanullah, M.T.O. Chapter 1 - Performance evaluation of hybrid earth pipe cooling with horizontal piping system, Thermofluid modeling for. 2016 En : energy efficiency applications. Elsevier Academic Press:
Paper not yet in RePEc: Add citation now
Bai, Y. ; Long, T. ; Li, W. Experimental investigation of natural ventilation characteristics of a solar chimney coupled with earth-air heat exchanger (SCEAHE) system in summer and winter. 2022 Renew. Energy. 193 1001-1018
Bisoniya, T.S. ; Kumar, A. ; Baredar, P. Experimental and analytical studies of earth–air heat exchanger (EAHE) systems in India: a review. 2013 Renew. Sustain. Energy Rev.. 19 238-246
Bordoloi, N. ; Sharma, A. ; Nautiyal, H. An intense review on the latest advancements of Earth Air Heat Exchangers. 2018 Renew. Sustain. Energy Rev.. 89 261-280
Dey, S. ; Sreenivasulu, A. ; Veerendra, G.T.N. Renewable energy present status and future potentials in India: an overview. 2022 Innovation Green Dev. 1 -
- Do, S.L. ; Baltazar, J.-C. ; Haberl, J. Potential cooling savings from a ground-coupled return-air duct system for residential buildings in hot and humid climates. 2015 Energy Build.. 103 206-215
Paper not yet in RePEc: Add citation now
- Estrada, E. ; Labat, M. ; Lorente, S. The impact of latent heat exchanges on the design of earth air heat exchangers. 2018 Appl. Therm. Eng.. 129 306-317
Paper not yet in RePEc: Add citation now
- Goff, J.A. Low-pressure Properties of Water from -160°F to 212°F, Trans-actions of the American Society of Heating and Ventilating Engineers. 1946 :
Paper not yet in RePEc: Add citation now
- Goswami, D.Y. ; Ileslamlou, S. Performance analysis of a closed-loop climate control system using underground air tunnel. 1990 J. SOL. ENERG-T. ASME.. 112 76-81
Paper not yet in RePEc: Add citation now
- Hepbasli, A. Low exergy modelling and performance analysis of greenhouses coupled to closed earth-to-air heat exchangers (EAHEs). 2013 Energy Build.. 64 224-230
Paper not yet in RePEc: Add citation now
- Incropera, F.P. ; DeWitt, D.P. Introduction to Heat Transfer. 1996 Wiley:
Paper not yet in RePEc: Add citation now
- Lapertot, A. ; Cuny, M. ; Kadoch, B. Optimization of an earth-air heat exchanger combined with a heat recovery ventilation for residential building needs. 2021 Energy Build.. 235 -
Paper not yet in RePEc: Add citation now
- Lian, Z.W. Principles and Equipments of Heat and Mass Transfer. 2001 Building Industry Press:
Paper not yet in RePEc: Add citation now
Liu, Z. ; Liu, Y. ; He, B.-J. Application and suitability analysis of the key technologies in nearly zero energy buildings in China. 2019 Renew. Sustain. Energy Rev.. 101 329-345
- Mathur, A. ; Srivastava, A. ; Agrawal, G.D. CFD analysis of EATHE system under transient conditions for intermittent operation. 2015 Energy Build.. 87 37-44
Paper not yet in RePEc: Add citation now
- Mathur, A. ; Surana, A.K. ; Verma, P. Investigation of soil thermal saturation and recovery under intermittent and continuous operation of EATHE. 2015 Energy Build.. 109 291-303
Paper not yet in RePEc: Add citation now
- Maytorena, V.M. ; Moreno, S. ; Hinojosa, J.F. Effect of operation modes on the thermal performance of EAHE systems with and without PCM in summer weather conditions. 2021 Energy Build.. 250 -
Paper not yet in RePEc: Add citation now
Minaei, A. ; Talee, Z. ; Safikhani, H. Thermal resistance capacity model for transient simulation of Earth-Air Heat Exchangers. 2021 Renew. Energy. 167 558-567
- Niu, F. ; Yu, Y. ; Yu, D. Investigation on soil thermal saturation and recovery of an earth to air heat exchanger under different operation strategies. 2015 Appl. Therm. Eng.. 77 90-100
Paper not yet in RePEc: Add citation now
- Ozgener, O. ; Ozgener, L. Determining the optimal design of a closed loop earth to air heat exchanger for greenhouse heating by using exergoeconomics. 2011 Energy Build.. 43 960-965
Paper not yet in RePEc: Add citation now
- Ozgener, O. ; Ozgener, L. ; Goswami, D.Y. Experimental prediction of total thermal resistance of a closed loop EAHE for greenhouse cooling system. 2011 Int. Commun. Heat Mass Tran.. 38 711-716
Paper not yet in RePEc: Add citation now
- Pérez-Lombard, L. ; Ortiz, J. ; Pout, C. A review on buildings energy consumption information. 2008 Energy Build.. 40 394-398
Paper not yet in RePEc: Add citation now
- Rouag, A. ; Benchabane, A. ; Mehdid, C.-E. Thermal design of Earth-to-Air Heat Exchanger. Part I a new transient semi-analytical model for determining soil temperature. 2018 J. Clean. Prod.. 182 538-544
Paper not yet in RePEc: Add citation now
Wei, H. ; Yang, D. ; Du, J. Field experiments on the effects of an earth-to-air heat exchanger on the indoor thermal environment in summer and winter for a typical hot-summer and cold-winter region. 2021 Renew. Energy. 167 530-541
Wei, H. ; Yang, D. ; Wang, J. Field experiments on the cooling capability of earth-to-air heat exchangers in hot and humid climate. 2020 Appl. Energy. 276 -
- Xiao, J. ; Wang, Q. ; Wang, X. An earth-air heat exchanger integrated with a greenhouse in cold-winter and hot-summer regions of northern China: modeling and experimental analysis. 2023 Appl. Therm. Eng.. 232 -
Paper not yet in RePEc: Add citation now
- Yang, D. ; Guo, Y. ; Zhang, J. Evaluation of the thermal performance of an earth-to-air heat exchanger (EAHE) in a harmonic thermal environment. 2016 Energy Convers. Manag.. 109 184-194
Paper not yet in RePEc: Add citation now
- Yang, D. ; Wei, H. ; Wang, J. Coupled heat and moisture transfer model to evaluate earth-to-air heat exchangers exposed to harmonically fluctuating thermal environments. 2021 Int. J. Heat Mass Tran.. 174 -
Paper not yet in RePEc: Add citation now
- Yue, Y. ; Yan, Z. ; Ni, P. ; Lei, F. ; Qin, G. Enhancing the performance of earth-air heat exchanger: a flexible multi-objective optimization framework. 2024 Appl. Therm. Eng.. 244 -
Paper not yet in RePEc: Add citation now
Zhou, X. ; Huang, Z. ; Scheuer, B. High-resolution estimation of building energy consumption at the city level. 2023 Energy. 275 -