SlideShare a Scribd company logo
4
Most read
5
Most read
9
Most read
DOOR INTERLOCKING SYSTEM PPT
DOOR INTERLOCKING SYSTEM PPT
 We are glad to introduce ourselves as pioneers in manufacturing Door
interlocking system with micro controller/processor based with Electro
Magnetic Locks to control cross contamination and air conditioning lossesi
n clean rooms, sterile areas and pass boxes.
System Description:
 Interlocking system can control two or more doors in a way that to give
access to any one door and it will never allow to open any adjacent two doors
simultaneously. The following are the most important characteristics of the
interlocking system
 Two Doors Closed mode: In this mode both doors are closed and locked by
means of electro Magnetic Lock or Electric Door Strike. Anyone who wants
to get the access can enter by passing the push button switch. When the first
door is opened second door remain closed till the first one is closed i.e. both
doors will not open simultaneously. There by you are preventing clean air
contamination and you are saving air conditioning losses.
 Two Door Open Mode: In this mode both doors are in normally closed
condition by means of door closure but unlocked. By opening door-1, door-
2 automatically gets locked and will not open till the first door is closed.
 Our control panels are available in 2-door, 4-door, 8-door & 16-door
control models.
 In case of any emergency like fire, our system is coming with 2 relay
outputs one will open all the doors another relay close all the doors in
special protection areas.
 According to your applications we will provide customized solutions. We
are satisfying our customers in pharmacy industry for the past 20 years by
providing accurate & adequate systems according to their requirement with
lowest possible prices.
Our Systems are very much applicable in the following areas.
 Clean rooms
 Pass boxes
 Air locks
 Pass through modules
 Bio clean workbench
 Air showers
 Clean room garment locker
 Operation theatres
 ICU’s etc., DOOR INTERLOCKING SYSTEM
Switches
Electro Magnetic Locks
Door Interlocking Control Panel
Technical Specifications For Control Panel
SNO PARAMETER SPECIFICATIONS
1 Power supply 230V, ±10% 50 Hz single phase
2 Operating voltage 12V D.C
3 Absorbed Current 500mAmp for control panel
4 No. of manoeuvres in 24 h Continuous service
5 Environmental conditions -15° C to +60° C
6 Control unit weight 0.4kg
7 Enclosure M.S Body powder coated / SS
Technical Specifications For Feather Touch Switches
Operating voltage: 2.5V D.C
Absorbed Current: 30 mAmp
Technical Specifications For Magnetic Contact
Operating voltage : 3.5 V D.C
Absorbed Current : 25 mAmp
CONTACT US
Shalom Enterprises,
Plot No – 412, Mallareddy Nagar,
Gajularamaram, Qutubullapur Mandal,
Hyderabad– 500 055, Ph : 040 – 3100 7374 /94,
E mail : info@shalomsystems.net mktg@shalomsystems.net
Web : www.shalomsystems.net
Mumbai Branch
Mr. Mark Vyas
Cont: 9869083170
E mail: mark@shalomsystems.net
Web : www.shalomsystems.net
Thank You

More Related Content

PDF
Manual conversor dc siemens
PPTX
Sensores proyecto de control PSM Valencia
PPTX
Summer training
PDF
NE_0101014_NENEW-min
PDF
NickFestari-PressRelease-180815
PDF
Bagmati flood 2009 presented by mr deepak bharti of vo ssvk bihar
PDF
التدريب الصيفي 2-حامد العنزي
PDF
ديوان الامام الشافعى
Manual conversor dc siemens
Sensores proyecto de control PSM Valencia
Summer training
NE_0101014_NENEW-min
NickFestari-PressRelease-180815
Bagmati flood 2009 presented by mr deepak bharti of vo ssvk bihar
التدريب الصيفي 2-حامد العنزي
ديوان الامام الشافعى

Viewers also liked (14)

PPTX
EL INTERNET
DOCX
Micronutrientes y macronutrientes
PDF
08 seca1
PPSX
Жанри фотографії
PPTX
Bab vii distribusi normal
PPTX
Distribusi normal
PPTX
Oyunlastirma Giriş - 1
PPTX
A Social Content Delivery Network for Scientific Cooperation: Vision, Design...
PPTX
ICSA 2016 - Mashrabiya Reinvented: Double Façades, Persian Gulf Style
PPTX
Lesson 3 simpsons rule
PDF
احمد ديدات بين الانجيل و القرآن
PDF
Ukuran tendensi sentral
PDF
Ukuran dispersi(5)
PDF
Penyajian data dalam_diagram(3)
EL INTERNET
Micronutrientes y macronutrientes
08 seca1
Жанри фотографії
Bab vii distribusi normal
Distribusi normal
Oyunlastirma Giriş - 1
A Social Content Delivery Network for Scientific Cooperation: Vision, Design...
ICSA 2016 - Mashrabiya Reinvented: Double Façades, Persian Gulf Style
Lesson 3 simpsons rule
احمد ديدات بين الانجيل و القرآن
Ukuran tendensi sentral
Ukuran dispersi(5)
Penyajian data dalam_diagram(3)
Ad

More from Shalom Enterprises (10)

PDF
Tyre Killer (Spikesystem)
PDF
Solar Power Fencing
PDF
Sliding Gate
PDF
Hydraulic Road Bollard
PDF
PDF
Door Interlocking System Broucher
PDF
SHALOM ISO CERTIFICATE
PDF
shalom clientlist
PDF
Introduction Of Shalom SYtems Pvt.Ltd
PPTX
GATE AUTOMATION PPT
Tyre Killer (Spikesystem)
Solar Power Fencing
Sliding Gate
Hydraulic Road Bollard
Door Interlocking System Broucher
SHALOM ISO CERTIFICATE
shalom clientlist
Introduction Of Shalom SYtems Pvt.Ltd
GATE AUTOMATION PPT
Ad

DOOR INTERLOCKING SYSTEM PPT

  • 3.  We are glad to introduce ourselves as pioneers in manufacturing Door interlocking system with micro controller/processor based with Electro Magnetic Locks to control cross contamination and air conditioning lossesi n clean rooms, sterile areas and pass boxes. System Description:  Interlocking system can control two or more doors in a way that to give access to any one door and it will never allow to open any adjacent two doors simultaneously. The following are the most important characteristics of the interlocking system  Two Doors Closed mode: In this mode both doors are closed and locked by means of electro Magnetic Lock or Electric Door Strike. Anyone who wants to get the access can enter by passing the push button switch. When the first door is opened second door remain closed till the first one is closed i.e. both doors will not open simultaneously. There by you are preventing clean air contamination and you are saving air conditioning losses.
  • 4.  Two Door Open Mode: In this mode both doors are in normally closed condition by means of door closure but unlocked. By opening door-1, door- 2 automatically gets locked and will not open till the first door is closed.  Our control panels are available in 2-door, 4-door, 8-door & 16-door control models.  In case of any emergency like fire, our system is coming with 2 relay outputs one will open all the doors another relay close all the doors in special protection areas.  According to your applications we will provide customized solutions. We are satisfying our customers in pharmacy industry for the past 20 years by providing accurate & adequate systems according to their requirement with lowest possible prices.
  • 5. Our Systems are very much applicable in the following areas.  Clean rooms  Pass boxes  Air locks  Pass through modules  Bio clean workbench  Air showers  Clean room garment locker  Operation theatres  ICU’s etc., DOOR INTERLOCKING SYSTEM
  • 9. Technical Specifications For Control Panel SNO PARAMETER SPECIFICATIONS 1 Power supply 230V, ±10% 50 Hz single phase 2 Operating voltage 12V D.C 3 Absorbed Current 500mAmp for control panel 4 No. of manoeuvres in 24 h Continuous service 5 Environmental conditions -15° C to +60° C 6 Control unit weight 0.4kg 7 Enclosure M.S Body powder coated / SS
  • 10. Technical Specifications For Feather Touch Switches Operating voltage: 2.5V D.C Absorbed Current: 30 mAmp Technical Specifications For Magnetic Contact Operating voltage : 3.5 V D.C Absorbed Current : 25 mAmp
  • 11. CONTACT US Shalom Enterprises, Plot No – 412, Mallareddy Nagar, Gajularamaram, Qutubullapur Mandal, Hyderabad– 500 055, Ph : 040 – 3100 7374 /94, E mail : info@shalomsystems.net mktg@shalomsystems.net Web : www.shalomsystems.net Mumbai Branch Mr. Mark Vyas Cont: 9869083170 E mail: mark@shalomsystems.net Web : www.shalomsystems.net