SlideShare a Scribd company logo
2
Most read
7
Most read
8
Most read
Relion® Protection and Control




Relion® 650 and 670 series instructions
How to use order specific files in
PCM600 2.x
How to use order specific files in PCM600 2.x                            March 24, 2010
 Instructions                                                                 1MRG000522
                                                                                   Rev. B




1. Introduction
This document is designed to instruct the users on how to use the IED order specific
files (more popular known as “option files”), more exactly – how to install them during
the new IED insertion and the Configuration Wizard process or later on with the
License Update Tool.

IED insertion if you work offline, follow the steps described in Chapter 2:
- If you don’t have access to the IED.

IED insertion if you work online, follow the steps described in Chapter 3:
- If you have access to the IED.

How to run License Update Tool, follow the steps described in Chapter 4:
- If you already started engineering.


2. If you don’t have access to the IED
These steps assume that you have access to the order specific files (e.g.
213314930.zip, i.e. ordernumber.zip)

Step 1
Unzip the file to extract the file “Orderoptions 213314930.xml“from it.

Step 2
Start PCM600 and insert your IED, the IED Configuration Wizard will then start.
Select the Offline option and click Next.




                                                                                   Figure 1
How to use order specific files in PCM600 2.x      March 24, 2010
 Instructions                                        1MRG000522
                                                           Rev. B




Step 3
Select communication protocol and click Next.




                                                           Figure 2

Step 4
Enter the IP address for your IED and click Next.




                                                           Figure 3
How to use order specific files in PCM600 2.x                        March 24, 2010
 Instructions                                                          1MRG000522
                                                                             Rev. B




Step 5
Select the IED version and click Next.




                                                                             Figure 4

Step 6
Select Browse and navigate to the directory containing the previously unzipped xml
file. Select the xml file, click Open and Next (Fig. 6 and Fig. 7).




                                                                             Figure 5
How to use order specific files in PCM600 2.x   March 24, 2010
Instructions                                     1MRG000522
                                                       Rev. B




                                                       Figure 6




                                                       Figure 7
How to use order specific files in PCM600 2.x                          March 24, 2010
 Instructions                                                            1MRG000522
                                                                               Rev. B




Step 7
Confirm the housing options, by clicking Next.




                                                                               Figure 8

Step 8
Click Finish on the last Configuration Wizard screen, to complete the IED insertion
process.




                                                                               Figure 9

You are ready now to use the inserted IED in PCM.
How to use order specific files in PCM600 2.x                          March 24, 2010
 Instructions                                                            1MRG000522
                                                                               Rev. B




3. If you have access to the IED
Start PCM600 and insert your IED, the IED Configuration Wizard will then start.
Select the Online option and click Next.




                                                                              Figure 10

Perform step 3 and 4 described in chapter 2 and then perform a scan on the IED that
you are connected to by clicking Scan and Next.




                                                                              Figure 11

Perform step 7 and 8 described in chapter 2, to complete the online installation. The
order options will be loaded from the IED.

You are ready now to use the inserted IED in PCM.
How to use order specific files in PCM600 2.x                                March 24, 2010
 Instructions                                                                  1MRG000522
                                                                                     Rev. B




4. If you already started engineering
For offline license update these steps assume that you have access to the order
specific files (e.g. 213314930.zip, i.e. ordernumber.zip)

Step 1
For offline license update unzip the file to extract the file “Orderoptions
213314930.xml“from it.

Step 2
Start License Update Tool by right clicking the IED and select “License Update Tool”.




                                                                                    Figure 12

Step 3
Select Yes or No to make a backup or not. It’s recommended to make a backup.




                                                                                    Figure 13
How to use order specific files in PCM600 2.x                        March 24, 2010
 Instructions                                                          1MRG000522
                                                                             Rev. B




Step 4
Select Online or Offline and click next.
For Offline follow step 5, 6 and 8.
For Online follow step 7 and 8.




                                                                            Figure 14

Step 5
Select Browse and navigate to the directory containing the previously unzipped xml
file. Select the xml file, click Open and Next.




                                                                            Figure 15
How to use order specific files in PCM600 2.x                        March 24, 2010
 Instructions                                                           1MRG000522
                                                                             Rev. B




Step 6
Click Finish on the last License Update Wizard screen, to complete the IED license
update process.




                                                                            Figure 16

Step 7
Click Finish on the last License Update Wizard screen, to complete the IED license
update process.




                                                                            Figure 17
How to use order specific files in PCM600 2.x                            March 24, 2010
 Instructions                                                              1MRG000522
                                                                                 Rev. B




Step 8
After completion a migration report is presented, showing deleted functionality.




                                                                                Figure 18

Deleted blocks are marked blue in Application Configuration Tool.




                                                                                Figure 19

If there are any deleted function blocks, you need to check the configuration and
make sure that all variables related to that function block are deleted as well and this
will not impact the configuration.

After this, you are ready now to continue using the IED in PCM.




5. Limitation
If the order option in the IED is updated and a read command is executed, operation
will fail. Hence the order option and the configuration will not match in the IED. To
avoid this situation it is recommended that always execute a write operation from
PCM with the new order options in order to synchronize the configuration and order
options both in IED and PCM.
How to use order specific files in PCM600 2.x   March 24, 2010
 Instructions                                     1MRG000522
                                                        Rev. B




ABB AB
Substation Automation Products
SE-721 59 Västerås
Sweden
Telephone: +46 (0) 21 34 20 00
Facsimile: +46 (0) 21 14 69 18
www.abb.com/substationautomation

More Related Content

PPTX
Sap fico demo presentation
PDF
Sap erp-financials-and-fico-handbook scribd
PDF
Sap basis r3 hand book
PPTX
Sap User Exit for Functional Consultant
PDF
SAP System copy
PPSX
3. optical storage
DOCX
Czech board games
PDF
Top 35-interview-questions-on-sap-abap
Sap fico demo presentation
Sap erp-financials-and-fico-handbook scribd
Sap basis r3 hand book
Sap User Exit for Functional Consultant
SAP System copy
3. optical storage
Czech board games
Top 35-interview-questions-on-sap-abap

What's hot (9)

PPTX
Queries in SAP: Introduction
PPT
ST03N(ワークロードモニター)データ取出し方法
DOCX
How to perform critical authorizations and so d checks in sap systems
PDF
RMA Operations and Repair Use Cases
PDF
Bapi step-by-step
PDF
Mastering SAP Monitoring - SAP SLT & RFC Connection Monitoring
PDF
Hebrew Gospel of Matthew by George Howard
DOC
Informixsql
PPTX
SAP HANA for SAP Overview
Queries in SAP: Introduction
ST03N(ワークロードモニター)データ取出し方法
How to perform critical authorizations and so d checks in sap systems
RMA Operations and Repair Use Cases
Bapi step-by-step
Mastering SAP Monitoring - SAP SLT & RFC Connection Monitoring
Hebrew Gospel of Matthew by George Howard
Informixsql
SAP HANA for SAP Overview
Ad

Viewers also liked (9)

PDF
1 mrg002586 configuration_migration_for_670_series_in_pcm600_user_manual
PDF
1 mrg004195 configuration_migration_for_650_series_in_pcm600_user_manual
PDF
Guia instalação PCM600 ABB
PDF
Pcm600 v2.5 installation guide
PDF
PCM600
PPTX
Measuring Social Media ROI - SMX Milan '13
PDF
Feedback Canvas
PDF
Bits Banderas de Europa 2º parte
PDF
Bits Inteligencia: Banderas Europa Lourdes Giraldo
1 mrg002586 configuration_migration_for_670_series_in_pcm600_user_manual
1 mrg004195 configuration_migration_for_650_series_in_pcm600_user_manual
Guia instalação PCM600 ABB
Pcm600 v2.5 installation guide
PCM600
Measuring Social Media ROI - SMX Milan '13
Feedback Canvas
Bits Banderas de Europa 2º parte
Bits Inteligencia: Banderas Europa Lourdes Giraldo
Ad

Similar to Como usar Order Specific Files (17)

PPTX
PCM600_ver_2.13_product_pres_2NGA001163_ENe.pptx
PDF
Pmcs user exits
PDF
Control relay via schedule time
PDF
Zos1.13 migration
PDF
Sh080272a
PDF
Sh080272a
PPTX
Oracle Database Appliance RAC in a box Some Strings Attached
PPS
Prodev Solutions Intro
TXT
Lun allocation
PPTX
ManageEngine OpManager - OEM on-boarding document
PDF
PLM Data Migration
PPTX
Lecture 4 client workstations
PDF
Cloudy with a chance of arm
PDF
Week 4 B IP Subnetting Lab Essay
PPTX
How to Manage By Products in Odoo 17 Manufacturing
PDF
Best Industrial Automation Software Development In India
PDF
Aws sdk-php-guide
PCM600_ver_2.13_product_pres_2NGA001163_ENe.pptx
Pmcs user exits
Control relay via schedule time
Zos1.13 migration
Sh080272a
Sh080272a
Oracle Database Appliance RAC in a box Some Strings Attached
Prodev Solutions Intro
Lun allocation
ManageEngine OpManager - OEM on-boarding document
PLM Data Migration
Lecture 4 client workstations
Cloudy with a chance of arm
Week 4 B IP Subnetting Lab Essay
How to Manage By Products in Odoo 17 Manufacturing
Best Industrial Automation Software Development In India
Aws sdk-php-guide

More from faqrelion (6)

PDF
Cronograma treinamento 2019_abb_relion_670_650_rtu500_rev2_pt
PDF
Cronograma treinamento 2018_abb_relion_670_650_rtu500_rev1_pt
PDF
Calendario Entrenamientos 2017
PDF
Cronograma Treinamento 2017
PDF
Cronograma treinamento 2015-abb_relion 670-650_rtu560_softwares_rev0 - br
PDF
Cronograma treinamento 2014-abb_relion 670-650_rtu560_softwares_rev1
Cronograma treinamento 2019_abb_relion_670_650_rtu500_rev2_pt
Cronograma treinamento 2018_abb_relion_670_650_rtu500_rev1_pt
Calendario Entrenamientos 2017
Cronograma Treinamento 2017
Cronograma treinamento 2015-abb_relion 670-650_rtu560_softwares_rev0 - br
Cronograma treinamento 2014-abb_relion 670-650_rtu560_softwares_rev1

Como usar Order Specific Files

  • 1. Relion® Protection and Control Relion® 650 and 670 series instructions How to use order specific files in PCM600 2.x
  • 2. How to use order specific files in PCM600 2.x March 24, 2010 Instructions 1MRG000522 Rev. B 1. Introduction This document is designed to instruct the users on how to use the IED order specific files (more popular known as “option files”), more exactly – how to install them during the new IED insertion and the Configuration Wizard process or later on with the License Update Tool. IED insertion if you work offline, follow the steps described in Chapter 2: - If you don’t have access to the IED. IED insertion if you work online, follow the steps described in Chapter 3: - If you have access to the IED. How to run License Update Tool, follow the steps described in Chapter 4: - If you already started engineering. 2. If you don’t have access to the IED These steps assume that you have access to the order specific files (e.g. 213314930.zip, i.e. ordernumber.zip) Step 1 Unzip the file to extract the file “Orderoptions 213314930.xml“from it. Step 2 Start PCM600 and insert your IED, the IED Configuration Wizard will then start. Select the Offline option and click Next. Figure 1
  • 3. How to use order specific files in PCM600 2.x March 24, 2010 Instructions 1MRG000522 Rev. B Step 3 Select communication protocol and click Next. Figure 2 Step 4 Enter the IP address for your IED and click Next. Figure 3
  • 4. How to use order specific files in PCM600 2.x March 24, 2010 Instructions 1MRG000522 Rev. B Step 5 Select the IED version and click Next. Figure 4 Step 6 Select Browse and navigate to the directory containing the previously unzipped xml file. Select the xml file, click Open and Next (Fig. 6 and Fig. 7). Figure 5
  • 5. How to use order specific files in PCM600 2.x March 24, 2010 Instructions 1MRG000522 Rev. B Figure 6 Figure 7
  • 6. How to use order specific files in PCM600 2.x March 24, 2010 Instructions 1MRG000522 Rev. B Step 7 Confirm the housing options, by clicking Next. Figure 8 Step 8 Click Finish on the last Configuration Wizard screen, to complete the IED insertion process. Figure 9 You are ready now to use the inserted IED in PCM.
  • 7. How to use order specific files in PCM600 2.x March 24, 2010 Instructions 1MRG000522 Rev. B 3. If you have access to the IED Start PCM600 and insert your IED, the IED Configuration Wizard will then start. Select the Online option and click Next. Figure 10 Perform step 3 and 4 described in chapter 2 and then perform a scan on the IED that you are connected to by clicking Scan and Next. Figure 11 Perform step 7 and 8 described in chapter 2, to complete the online installation. The order options will be loaded from the IED. You are ready now to use the inserted IED in PCM.
  • 8. How to use order specific files in PCM600 2.x March 24, 2010 Instructions 1MRG000522 Rev. B 4. If you already started engineering For offline license update these steps assume that you have access to the order specific files (e.g. 213314930.zip, i.e. ordernumber.zip) Step 1 For offline license update unzip the file to extract the file “Orderoptions 213314930.xml“from it. Step 2 Start License Update Tool by right clicking the IED and select “License Update Tool”. Figure 12 Step 3 Select Yes or No to make a backup or not. It’s recommended to make a backup. Figure 13
  • 9. How to use order specific files in PCM600 2.x March 24, 2010 Instructions 1MRG000522 Rev. B Step 4 Select Online or Offline and click next. For Offline follow step 5, 6 and 8. For Online follow step 7 and 8. Figure 14 Step 5 Select Browse and navigate to the directory containing the previously unzipped xml file. Select the xml file, click Open and Next. Figure 15
  • 10. How to use order specific files in PCM600 2.x March 24, 2010 Instructions 1MRG000522 Rev. B Step 6 Click Finish on the last License Update Wizard screen, to complete the IED license update process. Figure 16 Step 7 Click Finish on the last License Update Wizard screen, to complete the IED license update process. Figure 17
  • 11. How to use order specific files in PCM600 2.x March 24, 2010 Instructions 1MRG000522 Rev. B Step 8 After completion a migration report is presented, showing deleted functionality. Figure 18 Deleted blocks are marked blue in Application Configuration Tool. Figure 19 If there are any deleted function blocks, you need to check the configuration and make sure that all variables related to that function block are deleted as well and this will not impact the configuration. After this, you are ready now to continue using the IED in PCM. 5. Limitation If the order option in the IED is updated and a read command is executed, operation will fail. Hence the order option and the configuration will not match in the IED. To avoid this situation it is recommended that always execute a write operation from PCM with the new order options in order to synchronize the configuration and order options both in IED and PCM.
  • 12. How to use order specific files in PCM600 2.x March 24, 2010 Instructions 1MRG000522 Rev. B ABB AB Substation Automation Products SE-721 59 Västerås Sweden Telephone: +46 (0) 21 34 20 00 Facsimile: +46 (0) 21 14 69 18 www.abb.com/substationautomation