AccelOps uses Cisco UCS XML API to discover Cisco UCS and to collect hardware statistics.

Follow Cisco UCS documentation to enable AccelOps to connect to the device via Cisco UCS API.

Protocol   Information Discovered                      Metrics collected                     Used for
                                     Chassis status: Input Power, Input Avg Power, Input
                                     Max Power, Input Min Power, Output Power, Output
                                     Avg Power, Output Max Power, Output Min Power
                                     Memory status: Temp (C), Avg Temp (C), Max
                                     Temp (C), Min Temp (C)
                                     Processor status: Input Current, Input Avg Current,
                                     Input Max Current, Input Min Current, Temp (C), Avg
                                     Temp (C), Max Temp (C), Min Temp (C)
        Host name, Access IP,
                                     Power supply status: Temp (C), Max Temp (C), Avg
        Hardware components -
                                                                                         Availability and
Cisco   processors, chassis, blades, Temp (C), Min Temp (C), Input 210Volt, Avg Input
                                     210Volt, Max Input 210Volt, Min Input 210Volt,      Performance
UCS API board, cpu, memory,
                                     Output 12Volt, Avg Output 12Volt, Max Output        Monitoring
        storage, power supply unit,
                                     12Volt, Min Output 12Volt, Output 3V3Volt, Avg
        fan unit
                                     Output 3V3Volt, Max Output 3V3Volt, Min Output
                                     3V3Volt, Output Current, Avg Output Current, Max
                                     Output Current, Min Output Current, Output Power,
                                     Avg Output Power, Max Output Power,Min Output
                                     Power
                                     Fan status: Fan Speed, Average Fan Speed, Max Fan
                                     Speed, Min Fan Speed


Defining Cisco UCS credential in AccelOps

   1. Go to Admin > Setup wizard > Credentials
   2. In Step 1: Enter credentials, click Add and enter the following information and click Save
          o Name: name of this credential
          o Device type: Cisco UCS
          o Access protocol: UCS API
          o Credentials: user name and password
Test connectivity

   1. Go to Admin > Setup wizard > Credentials
   2. In Step 2: Enter IP range to credential associations, click Add and enter the following information and
      click Save
          o IP/HostName: IP address of the Cisco UCS device
          o Credentials: name of the Cisco UCS credential defined in the previous step
   3. Click Test Connectivity and make sure the test succeeds

Discovering Cisco UCS

   1. Go to Admin > Setup wizard > Discover infrastructure
   2. Click Add and enter the following information and press OK
          o Name: Name of this discovery
          o Discovery Type: Range Scan
          o Include Range and Exclude IP Ranges
   3. Select the discovery item and click Discover




   4. Go to Monitor Change/Performance and see the monitored Cisco UCS performance objects




Querying Cisco UCS events
Sample Cisco UCS events

Power Supply status event

[PH_DEV_MON_UCS_HW_PSU_STAT]:[eventSeverity]=PHL_INFO,[hostName]=machine,[hostIpAddr]=10.
1.2.36,[hwComponentName]=sys/chassis-1/psu-2,
[envTempdDegC]=47.764706,[envTempAvgDegC]=36.176472,[envTempMaxDegC]=47.764706,[envTempMi
nDegC]=25.529411,[input210Volt]=214.294113,
[input210AvgVolt]=210.784317,[input210MaxVolt]=214.294113,[input210MinVolt]=207.823532,[o
uput12Volt]=12.188235,[ouput12AvgVolt]=12.109803,
[ouput12MaxVolt]=12.376471,[ouput12MinVolt]=11.905882,[ouput3V3Volt]=3.141176,[ouput3V3Av
gVolt]=3.374510,[ouput3V3MaxVolt]=3.458823,
[ouput3V3MinVolt]=3.141176,[outputCurrentAmp]=15.686275,[outputCurrentAvgAmp]=20.261436,[
outputCurrentMaxAmp]=24.509804,
[outputCurrentMinAmp]=15.686275,[outputPowerWatt]=191.188004,[outputPowerAvgWatt]=245.736
252,[outputPowerMaxWatt]=303.344879,
[outputPowerMinWatt]=191.188004

Processor status event

[PH_DEV_MON_UCS_HW_PROCESSOR_STAT]:[eventSeverity]=PHL_INFO,
[hostName]=machine,[hostIpAddr]=10.1.2.36,
[hwComponentName]=sys/chassis-1/blade-3/board/cpu-2,
[inputCurrentAmp]=101.101959,[inputCurrentAvgAmp]=63.420914,
[inputCurrentMaxAmp]=101.101959,[inputCurrentMinAmp]=44.580391,
[envTempdDegC]=5.788235,[envTempAvgDegC]=6.216993,[envTempMaxDegC]=6.431373,[envTempMinDe
gC]=5.788235,

Chassis status event

[PH_DEV_MON_UCS_HW_CHASSIS_STAT]:[eventSeverity]=PHL_INFO,[hostName]=machine,[hostIpAddr
]=10.1.2.36,[hwComponentName]=sys/chassis-1,
[inputPowerWatt]=7.843137,[inputPowerAvgWatt]=7.843137,[inputPowerMaxWatt]=7.843137,[inpu
tPowerMinWatt]=7.843137,
outputPowerWatt]=0.000000,[outputPowerAvgWatt]=0.000000,[outputPowerMaxWatt]=0.000000,[ou
tputPowerMinWatt]=0.000000

Memory status event

[PH_DEV_MON_UCS_HW_MEMORY_STAT]:[eventSeverity]=PHL_INFO,[hostName]=machine,[hostIpAddr]=
10.1.2.36,
[hwComponentName]=sys/chassis-1/blade-1/board/memarray-1/mem-
9,[envTempdDegC]=51.000000,[envTempAvgDegC]=50.128208,
[envTempMaxDegC]=51.000000,[envTempMinDegC]=48.000000

Fan status event

[PH_DEV_MON_UCS_HW_FAN_STAT]:[eventSeverity]=PHL_INFO,[hostName]=machine,[hostIpAddr]=10.
1.2.36,
[hwComponentName]=sys/chassis-1/fan-module-1-5/fan-
2,[fanSpeed]=7800.000000,[fanSpeedAvg]=7049.000000,
[fanSpeedMax]=8550.000000,[fanSpeedMin]=2550.00000

More Related Content

PDF
Geth important commands
PPTX
Netmiko library
PPTX
Cryptography 101 for Java developers
PDF
Come configurare Liferay 6.0 per Oracle
PPTX
Owasp Indy Q2 2012 Advanced SQLi
PDF
使用 CLI 管理 OpenStack 平台
PDF
Build your own private openstack cloud
DOCX
ប្តូរឈ្មោះ Cpu
Geth important commands
Netmiko library
Cryptography 101 for Java developers
Come configurare Liferay 6.0 per Oracle
Owasp Indy Q2 2012 Advanced SQLi
使用 CLI 管理 OpenStack 平台
Build your own private openstack cloud
ប្តូរឈ្មោះ Cpu

What's hot (14)

TXT
PDF
Docker 基本概念與指令操作
PDF
R-House (LSRC)
PDF
Fail2ban - the system security for green hand -on linux os
PDF
Using New Web APIs For Your Own Pleasure – How I Wrote New Features For My Vi...
PDF
Forensic Challenge 10 - FC5 Attack Dataset Visualization
PDF
iCloud keychain
PPSX
Linux configer
PPTX
iOS Keychain 介紹
PPT
WiFi practical hacking "Show me the passwords!"
ODP
Getting started with RDO Havana
PDF
No more (unsecure) secrets, Marty
PPTX
{'python': 'dict'}
PDF
My Doc of geth
Docker 基本概念與指令操作
R-House (LSRC)
Fail2ban - the system security for green hand -on linux os
Using New Web APIs For Your Own Pleasure – How I Wrote New Features For My Vi...
Forensic Challenge 10 - FC5 Attack Dataset Visualization
iCloud keychain
Linux configer
iOS Keychain 介紹
WiFi practical hacking "Show me the passwords!"
Getting started with RDO Havana
No more (unsecure) secrets, Marty
{'python': 'dict'}
My Doc of geth
Ad

Similar to Cisco ucs support (20)

PPS
Iuwne10 S06 L01
PPTX
Industroyer: biggest threat to industrial control systems since Stuxnet by An...
PPTX
Embedded system
PPTX
VLSI Introduction to PSPICE
PPTX
ITE8_Chp3ciscoitessentialsslidessss.pptx
PDF
Pycon - Python for ethical hackers
PPTX
High-Volume Data Collection and Real Time Analytics Using Redis
PPTX
“Automation Testing for Embedded Systems”
PDF
Da APK al Golden Ticket
PDF
DEF CON 27- SHEILA A BERTA - backdooring hardware devices by injecting malici...
PDF
Hardware-Hacking-101 By Asutosh Kumar.pdf
PPTX
PLNOG15: Simplifying network deployment using Autonomic networking and Plug-a...
PPT
operating and configuring cisco a cisco IOS device
PDF
មេរៀនទីd៥ conneeeection with Arduino .pdf
PDF
[HES2013] Hacking apple accessories to pown iDevices – Wake up Neo! Your phon...
PPT
Arduino Platform with C programming.
PDF
Osic tech talk presentation on ironic inspector
PDF
Cisco 1900 series router datasheet
PDF
Shameful secrets of proprietary network protocols
PDF
BKK16-TR08 How to generate power models for EAS and IPA
Iuwne10 S06 L01
Industroyer: biggest threat to industrial control systems since Stuxnet by An...
Embedded system
VLSI Introduction to PSPICE
ITE8_Chp3ciscoitessentialsslidessss.pptx
Pycon - Python for ethical hackers
High-Volume Data Collection and Real Time Analytics Using Redis
“Automation Testing for Embedded Systems”
Da APK al Golden Ticket
DEF CON 27- SHEILA A BERTA - backdooring hardware devices by injecting malici...
Hardware-Hacking-101 By Asutosh Kumar.pdf
PLNOG15: Simplifying network deployment using Autonomic networking and Plug-a...
operating and configuring cisco a cisco IOS device
មេរៀនទីd៥ conneeeection with Arduino .pdf
[HES2013] Hacking apple accessories to pown iDevices – Wake up Neo! Your phon...
Arduino Platform with C programming.
Osic tech talk presentation on ironic inspector
Cisco 1900 series router datasheet
Shameful secrets of proprietary network protocols
BKK16-TR08 How to generate power models for EAS and IPA
Ad

Recently uploaded (20)

PDF
Computing-Curriculum for Schools in Ghana
PPTX
Tissue processing ( HISTOPATHOLOGICAL TECHNIQUE
PDF
Microbial disease of the cardiovascular and lymphatic systems
PPTX
human mycosis Human fungal infections are called human mycosis..pptx
PDF
A GUIDE TO GENETICS FOR UNDERGRADUATE MEDICAL STUDENTS
PDF
Weekly quiz Compilation Jan -July 25.pdf
PPTX
school management -TNTEU- B.Ed., Semester II Unit 1.pptx
PPTX
Cell Structure & Organelles in detailed.
PPTX
Pharmacology of Heart Failure /Pharmacotherapy of CHF
PDF
Yogi Goddess Pres Conference Studio Updates
PDF
Classroom Observation Tools for Teachers
PPTX
Orientation - ARALprogram of Deped to the Parents.pptx
PDF
Anesthesia in Laparoscopic Surgery in India
PPTX
Introduction-to-Literarature-and-Literary-Studies-week-Prelim-coverage.pptx
PDF
O7-L3 Supply Chain Operations - ICLT Program
PDF
Black Hat USA 2025 - Micro ICS Summit - ICS/OT Threat Landscape
PDF
Supply Chain Operations Speaking Notes -ICLT Program
PDF
Chinmaya Tiranga quiz Grand Finale.pdf
DOC
Soft-furnishing-By-Architect-A.F.M.Mohiuddin-Akhand.doc
PDF
The Lost Whites of Pakistan by Jahanzaib Mughal.pdf
Computing-Curriculum for Schools in Ghana
Tissue processing ( HISTOPATHOLOGICAL TECHNIQUE
Microbial disease of the cardiovascular and lymphatic systems
human mycosis Human fungal infections are called human mycosis..pptx
A GUIDE TO GENETICS FOR UNDERGRADUATE MEDICAL STUDENTS
Weekly quiz Compilation Jan -July 25.pdf
school management -TNTEU- B.Ed., Semester II Unit 1.pptx
Cell Structure & Organelles in detailed.
Pharmacology of Heart Failure /Pharmacotherapy of CHF
Yogi Goddess Pres Conference Studio Updates
Classroom Observation Tools for Teachers
Orientation - ARALprogram of Deped to the Parents.pptx
Anesthesia in Laparoscopic Surgery in India
Introduction-to-Literarature-and-Literary-Studies-week-Prelim-coverage.pptx
O7-L3 Supply Chain Operations - ICLT Program
Black Hat USA 2025 - Micro ICS Summit - ICS/OT Threat Landscape
Supply Chain Operations Speaking Notes -ICLT Program
Chinmaya Tiranga quiz Grand Finale.pdf
Soft-furnishing-By-Architect-A.F.M.Mohiuddin-Akhand.doc
The Lost Whites of Pakistan by Jahanzaib Mughal.pdf

Cisco ucs support

  • 1. Cisco UCS Support AccelOps uses Cisco UCS XML API to discover Cisco UCS and to collect hardware statistics. Follow Cisco UCS documentation to enable AccelOps to connect to the device via Cisco UCS API. Protocol Information Discovered Metrics collected Used for Chassis status: Input Power, Input Avg Power, Input Max Power, Input Min Power, Output Power, Output Avg Power, Output Max Power, Output Min Power Memory status: Temp (C), Avg Temp (C), Max Temp (C), Min Temp (C) Processor status: Input Current, Input Avg Current, Input Max Current, Input Min Current, Temp (C), Avg Temp (C), Max Temp (C), Min Temp (C) Host name, Access IP, Power supply status: Temp (C), Max Temp (C), Avg Hardware components - Availability and Cisco processors, chassis, blades, Temp (C), Min Temp (C), Input 210Volt, Avg Input 210Volt, Max Input 210Volt, Min Input 210Volt, Performance UCS API board, cpu, memory, Output 12Volt, Avg Output 12Volt, Max Output Monitoring storage, power supply unit, 12Volt, Min Output 12Volt, Output 3V3Volt, Avg fan unit Output 3V3Volt, Max Output 3V3Volt, Min Output 3V3Volt, Output Current, Avg Output Current, Max Output Current, Min Output Current, Output Power, Avg Output Power, Max Output Power,Min Output Power Fan status: Fan Speed, Average Fan Speed, Max Fan Speed, Min Fan Speed Defining Cisco UCS credential in AccelOps 1. Go to Admin > Setup wizard > Credentials 2. In Step 1: Enter credentials, click Add and enter the following information and click Save o Name: name of this credential o Device type: Cisco UCS o Access protocol: UCS API o Credentials: user name and password
  • 2. Test connectivity 1. Go to Admin > Setup wizard > Credentials 2. In Step 2: Enter IP range to credential associations, click Add and enter the following information and click Save o IP/HostName: IP address of the Cisco UCS device o Credentials: name of the Cisco UCS credential defined in the previous step 3. Click Test Connectivity and make sure the test succeeds Discovering Cisco UCS 1. Go to Admin > Setup wizard > Discover infrastructure 2. Click Add and enter the following information and press OK o Name: Name of this discovery o Discovery Type: Range Scan o Include Range and Exclude IP Ranges 3. Select the discovery item and click Discover 4. Go to Monitor Change/Performance and see the monitored Cisco UCS performance objects Querying Cisco UCS events
  • 3. Sample Cisco UCS events Power Supply status event [PH_DEV_MON_UCS_HW_PSU_STAT]:[eventSeverity]=PHL_INFO,[hostName]=machine,[hostIpAddr]=10. 1.2.36,[hwComponentName]=sys/chassis-1/psu-2, [envTempdDegC]=47.764706,[envTempAvgDegC]=36.176472,[envTempMaxDegC]=47.764706,[envTempMi nDegC]=25.529411,[input210Volt]=214.294113, [input210AvgVolt]=210.784317,[input210MaxVolt]=214.294113,[input210MinVolt]=207.823532,[o uput12Volt]=12.188235,[ouput12AvgVolt]=12.109803, [ouput12MaxVolt]=12.376471,[ouput12MinVolt]=11.905882,[ouput3V3Volt]=3.141176,[ouput3V3Av gVolt]=3.374510,[ouput3V3MaxVolt]=3.458823, [ouput3V3MinVolt]=3.141176,[outputCurrentAmp]=15.686275,[outputCurrentAvgAmp]=20.261436,[ outputCurrentMaxAmp]=24.509804, [outputCurrentMinAmp]=15.686275,[outputPowerWatt]=191.188004,[outputPowerAvgWatt]=245.736 252,[outputPowerMaxWatt]=303.344879, [outputPowerMinWatt]=191.188004 Processor status event [PH_DEV_MON_UCS_HW_PROCESSOR_STAT]:[eventSeverity]=PHL_INFO, [hostName]=machine,[hostIpAddr]=10.1.2.36, [hwComponentName]=sys/chassis-1/blade-3/board/cpu-2, [inputCurrentAmp]=101.101959,[inputCurrentAvgAmp]=63.420914, [inputCurrentMaxAmp]=101.101959,[inputCurrentMinAmp]=44.580391, [envTempdDegC]=5.788235,[envTempAvgDegC]=6.216993,[envTempMaxDegC]=6.431373,[envTempMinDe gC]=5.788235, Chassis status event [PH_DEV_MON_UCS_HW_CHASSIS_STAT]:[eventSeverity]=PHL_INFO,[hostName]=machine,[hostIpAddr ]=10.1.2.36,[hwComponentName]=sys/chassis-1, [inputPowerWatt]=7.843137,[inputPowerAvgWatt]=7.843137,[inputPowerMaxWatt]=7.843137,[inpu tPowerMinWatt]=7.843137, outputPowerWatt]=0.000000,[outputPowerAvgWatt]=0.000000,[outputPowerMaxWatt]=0.000000,[ou tputPowerMinWatt]=0.000000 Memory status event [PH_DEV_MON_UCS_HW_MEMORY_STAT]:[eventSeverity]=PHL_INFO,[hostName]=machine,[hostIpAddr]= 10.1.2.36, [hwComponentName]=sys/chassis-1/blade-1/board/memarray-1/mem- 9,[envTempdDegC]=51.000000,[envTempAvgDegC]=50.128208, [envTempMaxDegC]=51.000000,[envTempMinDegC]=48.000000 Fan status event [PH_DEV_MON_UCS_HW_FAN_STAT]:[eventSeverity]=PHL_INFO,[hostName]=machine,[hostIpAddr]=10. 1.2.36, [hwComponentName]=sys/chassis-1/fan-module-1-5/fan- 2,[fanSpeed]=7800.000000,[fanSpeedAvg]=7049.000000, [fanSpeedMax]=8550.000000,[fanSpeedMin]=2550.00000