Fabric Extender
Nexus 2000 Overview
• N2K Fabric Extender (FEX) acts as a remote line
card of 7K or 5K chassis
• All management performed on Parent Switch
– No console or VTY ports on FEX
– NX-OS automatically downloaded from Parent
• No local switching
– Traffic between local ports on FEX must flow “north”
via uplink to Parent and then “south” back down
– Can impact design decision of platform placement
FEX Types
Top of Many Rack
End of Row Rack
Middle of Row Rack
Top of Row Rack
Advantages
FEX Terminology
• Fabric Interface
• Host Interface
• Logical Interface
• Virtual Interface
Virtual Network Tag
Tag Info
The VNTag is inserted between the source MAC address and
the IEEE 802.1Q fields from the original Ethernet frame.
The VNTag fields are :
• Ethertype: This field identifies a VNTag frame. IEEE
reserved the value 0x8926 for Cisco VNTag.
• Direction bit (d): A 0 indicates that the frame is traveling
from the FEX to the parent switch. A 1 means that the
frame is traveling from the parent switch to the FEX.
• Pointer bit (p): A 1 indicates that a Vif_list_id is included in
the tag. A 0 signals that a Dvif_id is included in the frame.
Tag Info
• Virtual Interface List Identifier (Vif_list_id): This is a 14-bit value mapped to a
listof host interfaces to which this frame must be forwarded.
• Destination Virtual Interface Identifier (Dvif_id): This is a 12-bit value mapped toa
single host interface to which an Ethernet frame will be forwarded.
• Looped bit (l): This field indicates a multicast frame that was forwarded out the
switch port and later received. In this case, the FEX checks the Svif_id and filters
the frame from the corresponding port.
• Reserved bit (r): This bit is reserved for future use.
• Source Virtual Interface Identifier (Svif_id): This is a 12-bit value mapped to the
host interface that received this frame (if it is going from the FEX to the parent
switch).
5K vs 7K
5K as FEX’s Parent
– Supports Static Pinning & vPC Topologies
– FEX ports are L2 switchports
• 7K as FEX’s Parent
– Not all line cards support FEX
– Static Pinning only
• FEX link must be Port-Channel
– FEX ports are L2 switchports or native L3 routed
interfaces
SDP
7000 Basic requirement
Other Requirement
Connection Option
Static Pinning
Initialize FEX feature set
– feature fex on N5K
– install feature-set fex & feature-set fex on N7K
• Configure downlinks to FEX
– switchport mode fex
– fex associate [num]
– 7K requires Port-Channel to FEX
• FEX should be discovered by Parent
– show fex [detail]
– NX-OS download to FEX takes a few minutes
– Once complete FEX appears as just normal ports on Parent
Port channel
Design
Prepositioning
Question???

More Related Content

PDF
Software-Defined WAN: A Real World Success Story
PDF
TechWiseTV Workshop: Software-Defined Access
PPT
Deploying Carrier Ethernet features on ASR 9000
PDF
Reference Architecture-Validated & Tested Approach to Define Network Design
PDF
VMレプリケーション なら 「オンプレ」「クラウド」自由自在 【Zerto(ゼルト)】とは?
PDF
Securing the Onion: 5G Cloud Native Infrastructure
ODP
Introduction to Optee (26 may 2016)
PDF
XPDDS17: Reworking the ARM GIC Emulation & Xen Challenges in the ARM ITS Emu...
Software-Defined WAN: A Real World Success Story
TechWiseTV Workshop: Software-Defined Access
Deploying Carrier Ethernet features on ASR 9000
Reference Architecture-Validated & Tested Approach to Define Network Design
VMレプリケーション なら 「オンプレ」「クラウド」自由自在 【Zerto(ゼルト)】とは?
Securing the Onion: 5G Cloud Native Infrastructure
Introduction to Optee (26 may 2016)
XPDDS17: Reworking the ARM GIC Emulation & Xen Challenges in the ARM ITS Emu...

What's hot (20)

PDF
TEE - kernel support is now upstream. What this means for open source security
PDF
Segment Routing Technology Deep Dive and Advanced Use Cases
PDF
ISE-CiscoLive.pdf
PDF
Brkarc 3470 - cisco nexus 7000-7700 switch architecture (2016 las vegas) - 2 ...
PDF
Cisco Live! :: Cisco ASR 9000 Architecture :: BRKARC-2003 | Milan Jan/2014
PPTX
TensorFlow Studying Part II for GPU
PPTX
5G O-RAN 架構介紹
PPTX
VMware Advance Troubleshooting Workshop - Day 2
PPTX
Static partitioning virtualization on RISC-V
PDF
TEE (Trusted Execution Environment)は第二の仮想化技術になるか?
PDF
Service Function Chaining with SRv6
PDF
Aether: The First Open Source 5G/LTE Connected Edge Cloud Platform
PDF
LAS16-111: Easing Access to ARM TrustZone – OP-TEE and Raspberry Pi 3
PDF
ePRTC in data centers - GNSS-backup-as-a-service (GBaaS)
PDF
Inter-DCI and co-packaged optics
PDF
これだけは知っておきたい5Gのキホン - 5Gビジネスに必要な基礎知識
PDF
TechWiseTV Workshop: Cisco Catalyst 9600: Deep Dive and Design Considerations
PDF
5G – Enable, elevate, and emerge Digitalising us to infinity and beyond
PPTX
Packet light short1
PDF
Q4.11: Introduction to eMMC
TEE - kernel support is now upstream. What this means for open source security
Segment Routing Technology Deep Dive and Advanced Use Cases
ISE-CiscoLive.pdf
Brkarc 3470 - cisco nexus 7000-7700 switch architecture (2016 las vegas) - 2 ...
Cisco Live! :: Cisco ASR 9000 Architecture :: BRKARC-2003 | Milan Jan/2014
TensorFlow Studying Part II for GPU
5G O-RAN 架構介紹
VMware Advance Troubleshooting Workshop - Day 2
Static partitioning virtualization on RISC-V
TEE (Trusted Execution Environment)は第二の仮想化技術になるか?
Service Function Chaining with SRv6
Aether: The First Open Source 5G/LTE Connected Edge Cloud Platform
LAS16-111: Easing Access to ARM TrustZone – OP-TEE and Raspberry Pi 3
ePRTC in data centers - GNSS-backup-as-a-service (GBaaS)
Inter-DCI and co-packaged optics
これだけは知っておきたい5Gのキホン - 5Gビジネスに必要な基礎知識
TechWiseTV Workshop: Cisco Catalyst 9600: Deep Dive and Design Considerations
5G – Enable, elevate, and emerge Digitalising us to infinity and beyond
Packet light short1
Q4.11: Introduction to eMMC
Ad

Viewers also liked (18)

PPTX
VDC by NETWORKERS HOME
PPTX
OTV PPT by NETWORKERS HOME
PDF
vPC_Final
PPT
ASBIS: Virtualization Aware Networking - Cisco Nexus 1000V
PPTX
VPC PPT @NETWORKERSHOME
PPTX
VMware Networking, CISCO Nexus 1000V, and CISCO UCS VM-FEX
PPTX
Vpc notes
PPT
Fibre Channel over Ethernet (FCoE), iSCSI and the Converged Data Center
PPTX
A review of network concepts base on CISCO by Ali Shahbazi
PPTX
NETWORKERS HOME Cisco UCS PPT .
PDF
Inter VLAN Routing
PDF
Fiber Channel over Ethernet (FCoE) – Design, operations and management best p...
PPTX
LAN Switching and Wireless: Ch3 - Virtual Local Area Networks (VLANs)
PPTX
CCNA 2 Routing and Switching v5.0 Chapter 3
PPTX
CCNA 2 Routing and Switching v5.0 Chapter 5
PPTX
CCNA 1 Routing and Switching v5.0 Chapter 7
PPTX
CCNA 1 Routing and Switching v5.0 Chapter 4
PPTX
CCNA 1 Routing and Switching v5.0 Chapter 2
VDC by NETWORKERS HOME
OTV PPT by NETWORKERS HOME
vPC_Final
ASBIS: Virtualization Aware Networking - Cisco Nexus 1000V
VPC PPT @NETWORKERSHOME
VMware Networking, CISCO Nexus 1000V, and CISCO UCS VM-FEX
Vpc notes
Fibre Channel over Ethernet (FCoE), iSCSI and the Converged Data Center
A review of network concepts base on CISCO by Ali Shahbazi
NETWORKERS HOME Cisco UCS PPT .
Inter VLAN Routing
Fiber Channel over Ethernet (FCoE) – Design, operations and management best p...
LAN Switching and Wireless: Ch3 - Virtual Local Area Networks (VLANs)
CCNA 2 Routing and Switching v5.0 Chapter 3
CCNA 2 Routing and Switching v5.0 Chapter 5
CCNA 1 Routing and Switching v5.0 Chapter 7
CCNA 1 Routing and Switching v5.0 Chapter 4
CCNA 1 Routing and Switching v5.0 Chapter 2
Ad

Similar to FEX -PPT By NETWORKERS HOME (20)

PPTX
Cisco nx os
PPTX
Cisco nexus series
PPTX
Networkinginxenserver
PPTX
CCNA 200-301 Chapter 2-Fundamentals of Ethernet Lans.pptx
PPTX
CCNA 200-301 Chapter 2-Fundamentals of Ethernet Lans.pptx
PPTX
Introduction to nexux from zero to Hero
PPSX
Juniper for Enterprise
PPTX
CCNA 200-301 Chapter 2-Fundamentals of Ethernet Lans.pptx
PPT
Communication using network
PPT
Layer 2 forwarding on an spb fabric
PDF
Advanced TCP/IP-based Industrial Networking for Engineers & Technicians
DOCX
Cisco nexus 7000, nexus 5000 and 2000 fa qs
PPTX
Training Nexus 7 data & operation 2024.pptx
PPT
Lan basic
PDF
Ethernet Frames Explained
PPT
layer2-network-design.ppt
PPTX
CN Unit 2 PPT.pptx
DOCX
Ethernet
PPTX
Ethernet 802.3.pptx
PPTX
Gefen: Video over IP and Cascading Retail Wall
Cisco nx os
Cisco nexus series
Networkinginxenserver
CCNA 200-301 Chapter 2-Fundamentals of Ethernet Lans.pptx
CCNA 200-301 Chapter 2-Fundamentals of Ethernet Lans.pptx
Introduction to nexux from zero to Hero
Juniper for Enterprise
CCNA 200-301 Chapter 2-Fundamentals of Ethernet Lans.pptx
Communication using network
Layer 2 forwarding on an spb fabric
Advanced TCP/IP-based Industrial Networking for Engineers & Technicians
Cisco nexus 7000, nexus 5000 and 2000 fa qs
Training Nexus 7 data & operation 2024.pptx
Lan basic
Ethernet Frames Explained
layer2-network-design.ppt
CN Unit 2 PPT.pptx
Ethernet
Ethernet 802.3.pptx
Gefen: Video over IP and Cascading Retail Wall

More from networkershome (7)

PDF
Rack access guidelines 2
DOCX
Nexus 1000 v access guide
TXT
DOCX
Full rack access guide 1
PPTX
L3 and Multicasting PPT by NETWORKERS HOME
PPTX
Fabric Path PPT by NETWORKERS HOME
PPTX
Mastering checkpoint-1-basic-installation
Rack access guidelines 2
Nexus 1000 v access guide
Full rack access guide 1
L3 and Multicasting PPT by NETWORKERS HOME
Fabric Path PPT by NETWORKERS HOME
Mastering checkpoint-1-basic-installation

Recently uploaded (20)

PDF
Classroom Observation Tools for Teachers
PPTX
human mycosis Human fungal infections are called human mycosis..pptx
PDF
3rd Neelam Sanjeevareddy Memorial Lecture.pdf
PPTX
GDM (1) (1).pptx small presentation for students
PDF
102 student loan defaulters named and shamed – Is someone you know on the list?
PPTX
Microbial diseases, their pathogenesis and prophylaxis
PDF
2.FourierTransform-ShortQuestionswithAnswers.pdf
PDF
01-Introduction-to-Information-Management.pdf
PDF
Basic Mud Logging Guide for educational purpose
PDF
Module 4: Burden of Disease Tutorial Slides S2 2025
PDF
Supply Chain Operations Speaking Notes -ICLT Program
PDF
Sports Quiz easy sports quiz sports quiz
PDF
The Lost Whites of Pakistan by Jahanzaib Mughal.pdf
PDF
Complications of Minimal Access Surgery at WLH
PPTX
Cell Structure & Organelles in detailed.
PDF
Computing-Curriculum for Schools in Ghana
PPTX
Institutional Correction lecture only . . .
PDF
Insiders guide to clinical Medicine.pdf
PDF
STATICS OF THE RIGID BODIES Hibbelers.pdf
PPTX
Pharmacology of Heart Failure /Pharmacotherapy of CHF
Classroom Observation Tools for Teachers
human mycosis Human fungal infections are called human mycosis..pptx
3rd Neelam Sanjeevareddy Memorial Lecture.pdf
GDM (1) (1).pptx small presentation for students
102 student loan defaulters named and shamed – Is someone you know on the list?
Microbial diseases, their pathogenesis and prophylaxis
2.FourierTransform-ShortQuestionswithAnswers.pdf
01-Introduction-to-Information-Management.pdf
Basic Mud Logging Guide for educational purpose
Module 4: Burden of Disease Tutorial Slides S2 2025
Supply Chain Operations Speaking Notes -ICLT Program
Sports Quiz easy sports quiz sports quiz
The Lost Whites of Pakistan by Jahanzaib Mughal.pdf
Complications of Minimal Access Surgery at WLH
Cell Structure & Organelles in detailed.
Computing-Curriculum for Schools in Ghana
Institutional Correction lecture only . . .
Insiders guide to clinical Medicine.pdf
STATICS OF THE RIGID BODIES Hibbelers.pdf
Pharmacology of Heart Failure /Pharmacotherapy of CHF

FEX -PPT By NETWORKERS HOME

  • 2. Nexus 2000 Overview • N2K Fabric Extender (FEX) acts as a remote line card of 7K or 5K chassis • All management performed on Parent Switch – No console or VTY ports on FEX – NX-OS automatically downloaded from Parent • No local switching – Traffic between local ports on FEX must flow “north” via uplink to Parent and then “south” back down – Can impact design decision of platform placement
  • 4. Top of Many Rack
  • 5. End of Row Rack
  • 7. Top of Row Rack
  • 9. FEX Terminology • Fabric Interface • Host Interface • Logical Interface • Virtual Interface
  • 11. Tag Info The VNTag is inserted between the source MAC address and the IEEE 802.1Q fields from the original Ethernet frame. The VNTag fields are : • Ethertype: This field identifies a VNTag frame. IEEE reserved the value 0x8926 for Cisco VNTag. • Direction bit (d): A 0 indicates that the frame is traveling from the FEX to the parent switch. A 1 means that the frame is traveling from the parent switch to the FEX. • Pointer bit (p): A 1 indicates that a Vif_list_id is included in the tag. A 0 signals that a Dvif_id is included in the frame.
  • 12. Tag Info • Virtual Interface List Identifier (Vif_list_id): This is a 14-bit value mapped to a listof host interfaces to which this frame must be forwarded. • Destination Virtual Interface Identifier (Dvif_id): This is a 12-bit value mapped toa single host interface to which an Ethernet frame will be forwarded. • Looped bit (l): This field indicates a multicast frame that was forwarded out the switch port and later received. In this case, the FEX checks the Svif_id and filters the frame from the corresponding port. • Reserved bit (r): This bit is reserved for future use. • Source Virtual Interface Identifier (Svif_id): This is a 12-bit value mapped to the host interface that received this frame (if it is going from the FEX to the parent switch).
  • 13. 5K vs 7K 5K as FEX’s Parent – Supports Static Pinning & vPC Topologies – FEX ports are L2 switchports • 7K as FEX’s Parent – Not all line cards support FEX – Static Pinning only • FEX link must be Port-Channel – FEX ports are L2 switchports or native L3 routed interfaces
  • 14. SDP
  • 18. Static Pinning Initialize FEX feature set – feature fex on N5K – install feature-set fex & feature-set fex on N7K • Configure downlinks to FEX – switchport mode fex – fex associate [num] – 7K requires Port-Channel to FEX • FEX should be discovered by Parent – show fex [detail] – NX-OS download to FEX takes a few minutes – Once complete FEX appears as just normal ports on Parent