SlideShare a Scribd company logo
ALTERNATING CURRENTS
1. Alternating EMF and Current
2. Average or Mean Value of Alternating EMF and Current
3. Root Mean Square Value of Alternating EMF and Current
4. A C Circuit with Resistor
5. A C Circuit with Inductor
6. A C Circuit with Capacitor
7. A C Circuit with Series LCR – Resonance and Q-Factor
8. Graphical Relation between Frequency vs XL, XC
9. Power in LCR A C Circuit
10.Watt-less Current
11.L C Oscillations
12.Transformer
13.A.C. Generator
Created by C. Mani, Principal, K V No.1, AFS, Jalahalli West, Bangalore
Alternating emf:
Alternating emf is that emf which continuously changes in magnitude and
periodically reverses its direction.
Alternating Current:
Alternating current is that current which continuously changes in magnitude
and periodically reverses its direction.
T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T
t
0
π 2π 3π 4π
π/2 3π/2 5π/2 7π/2 θ = ωt
E
,I E0
I0
E = E0 sin ωt
I = I0 sin ωt
E, I – Instantaneous value of emf and current
E0, I0 – Peak or maximum value or amplitude of emf and current
ω – Angular frequency t – Instantaneous time
ωt – Phase
T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T
t
0
π 2π 3π 4π
π/2 3π/2 5π/2 7π/2 θ = ωt
E
,I E0
I0
E = E0 cos ωt
I = I0 cos ωt
Symbol of
AC Source
Average or Mean Value of Alternating Current:
Average or Mean value of alternating current over half cycle is that steady
current which will send the same amount of charge in a circuit in the time of
half cycle as is sent by the given alternating current in the same circuit in
the same time.
dq = I dt = I0 sin ωt dt
q = ∫ I0 sin ωt dt
0
T/2
q = 2 I0 / ω = 2 I0 T / 2π = I0 T / π
Mean Value of AC, Im = Iav = q / (T/2)
Im = Iav = 2 I0 / π = 0.637 I0 = 63.7 % I0
Average or Mean Value of Alternating emf:
Em = Eav = 2 E0 / π = 0.637 E0 = 63.7 %
E0
Note: Average or Mean value of alternating current or emf is zero over a
cycle as the + ve and – ve values get cancelled.
Root Mean Square or Virtual or Effective Value of
Alternating Current:
Root Mean Square (rms) value of alternating current is that steady current
which would produce the same heat in a given resistance in a given time as
is produced by the given alternating current in the same resistance in the
same time.
dH = I2R dt = I0
2 R sin2 ωt dt
H = ∫ I0
2 R sin2 ωt dt
0
T
H = I0
2 RT / 2
If Iv be the virtual value of AC, then
Iv = Irms = Ieff = I0 / √2 = 0.707 I0 = 70.7 % I0
Root Mean Square or Virtual or Effective Value of
Alternating emf: Ev = Erms = Eeff = E0 / √2 = 0.707 E0 = 70.7 % E0
Note:
1. Root Mean Square value of alternating current or emf can be calculated over any
period of the cycle since it is based on the heat energy produced.
2. Do not use the above formulae if the time interval under the consideration is less than
one period.
(After integration, ω is replaced with 2 π / T)
H = Iv
2 RT
0
π 2π 3π 4π
T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T
t
π/2 3π/2 5π/2 7π/2 θ = ωt
E0
Ev
Em
Relative Values Peak,
Virtual and Mean Values of
Alternating emf:
Em = Eav = 0.637 E0
Ev = Erms = Eeff = 0.707
E0
Tips:
1. The given values of alternating emf and current are virtual values unless
otherwise specified.
i.e. 230 V AC means Ev = Erms = Eeff = 230 V
2. AC Ammeter and AC Voltmeter read the rms values of alternating current
and voltage respectively.
They are called as ‘hot wire meters’.
3. The scale of DC meters is linearly graduated where as the scale of AC
meters is not evenly graduated because H α I2
AC Circuit with a Pure Resistor: R
E = E0 sin ωt
E = E0 sin ωt
I = E / R
= (E0 / R) sin ωt
I = I0 sin ωt (where I0 = E0 / R and R = E0 / I0)
Emf and current are in same phase.
T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T
t
0
π 2π 3π 4π
π/2 3π/2 5π/2 7π/2 θ = ωt
E
,I E0
I0
E = E0 sin ωt
I = I0 sin ωt
E0
I0
ωt
y
x
0
x
0
AC Circuit with a Pure Inductor:
L
E = E0 sin ωt
E = E0 sin ωt
T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T
t
π 2π 3π 4π
π/2 3π/2 5π/2 7π/2 θ = ωt
E
,I E0
I0
E = E0 sin ωt
I = I0 sin (ωt - π / 2)
E0
ωt
Induced emf in the inductor is - L (dI / dt)
In order to maintain the flow of current, the
applied emf must be equal and opposite to
the induced emf.
E = L (dI / dt)
E0 sin ωt = L (dI / dt)
dI = (E0 / L) sin ωt dt
I = ∫ (E0 / L) sin ωt dt
I = (E0 / ωL) ( - cos ωt )
I = I0 sin (ωt - π / 2)
(where I0 = E0 / ωL and XL = ωL = E0 / I0)
XL is Inductive Reactance. Its SI unit is ohm.
I0
y
Current lags behind emf by π/2 rad.
0
π/2
y
AC Circuit with a Capacitor:
E = E0 sin ωt
E = E0 sin ωt
T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T
t
0
π 2π 3π 4π
π/2 3π/2 5π/2 7π/2 θ = ωt
E
,I E0
I0
E = E0 sin ωt
I = I0 sin (ωt + π / 2)
E0
ωt
q = CE = CE0 sin ωt
I = dq / dt
= (d / dt) [CE0 sin ωt]
I = [E0 / (1 / ωC)] ( cos ωt )
I = I0 sin (ωt + π / 2)
(where I0 = E0 / (1 / ωC) and
XC = 1 / ωC = E0 / I0)
XC is Capacitive Reactance.
Its SI unit is ohm.
I0
π/2
x
0
Current leads the emf by π/2 radians.
C
Variation of XL with Frequency:
I0 = E0 / ωL and XL = ωL
XL is Inductive Reactance and ω = 2π f
XL = 2π f L i.e. XL α f
XL
f
0
Variation of XC with Frequency:
I0 = E0 / (1/ωC) and XC = 1 / ωC
XC is Inductive Reactance and ω = 2π f
XC = 1 / 2π f C i.e. XC α 1 / f
XC
f
0
TIPS:
1) Inductance (L) can not decrease Direct Current. It can only decrease
Alternating Current.
2) Capacitance (C) allows AC to flow through it but blocks DC.
AC Circuit with L, C, R in Series
Combination:
E = E0 sin ωt
C
L R
VL
VC
VR
1) In R, current and voltage are in
phase.
2) In L, current lags behind voltage by
π/2
3) In C, current leads the voltage by
π/2 VR
VL
VC
I
π/2
π/2
- VC
VL
VR
I
π/2
VL - VC
VR
I
E
Φ
E = √ [VR
2 + (VL –
VC)2]
The applied emf appears as
Voltage drops VR, VL and VC
across R, L and C respectively.
E = √ [VR
2 + (VL – VC)2]
I =
E
√ [R2 + (XL – XC)2]
Z = √ [R2 + (XL – XC)2]
Z = √ [R2 + (ω L – 1/ωC)2]
tan Φ =
XL – XC
R
tan Φ =
ω L – 1/ωC
R
or
0
VC
or
tan Φ =
XL – XC
R
tan Φ =
ω L – 1/ωC
R
Special Cases:
Case I: When XL > XC i.e. ω L > 1/ωC,
tan Φ = +ve or Φ is +ve
The current lags behind the emf by phase angle Φ and the LCR
circuit is inductance - dominated circuit.
Case II: When XL < XC i.e. ω L < 1/ωC,
tan Φ = -ve or Φ is -ve
The current leads the emf by phase angle Φ and the LCR circuit is
capacitance - dominated circuit.
Case III: When XL = XC i.e. ω L = 1/ωC,
tan Φ = 0 or Φ is 0°
The current and the emf are in same phase. The impedance does
not depend on the frequency of the applied emf. LCR circuit
behaves like a purely resistive circuit.
Resonance in AC Circuit with L, C, R:
When XL = XC i.e. ω L = 1/ωC, tan Φ = 0 or Φ is 0° and
Z = √ [R2 + (ω L – 1/ωC)2] becomes Zmin = R and I0max = E / R
i.e. The impedance offered by the circuit is minimum and the
current is maximum. This condition is called resonant condition
of LCR circuit and the frequency is called resonant frequency.
At resonant angular frequency ωr,
ωr L = 1/ωrC or ωr = 1 / √LC or fr = 1 / (2π √LC)
ωr
I0max
ω
0
R1
R2
R3
I0
I0max / √2
ωr - ∆ ω ωr + ∆ ω
Band width = 2 ∆ ω
Quality factor (Q – factor) is defined as the
ratio of resonant frequency to band width.
Q = ωr / 2 ∆ ω
or Q = ωr L / R or Q = 1 / ωrCR
Q = VL / VR or Q = VC / VR
Resonant Curve & Q - Factor:
It can also be defined as the ratio of potential
drop across either the inductance or the
capacitance to the potential drop across the
resistance.
R1 < R2 < R3
Power in AC Circuit with L, C, R:
Instantaneous Power = E I
= E0 I0 sin ωt sin (ωt + Φ)
= E0 I0 [sin2 ωt cosΦ + sin ωt cosωt cosΦ]
E = E0 sin ωt
I = I0 sin (ωt + Φ) (where Φ is the phase angle between emf and current)
If the instantaneous power is assumed to be constant for an
infinitesimally small time dt, then the work done is
dW = E0 I0 [sin2 ωt cosΦ + sin ωt cosωt cosΦ]
Work done over a complete cycle is
W = ∫ E0 I0 [sin2 ωt cosΦ + sin ωt cosωt cosΦ] dt
0
T
W = E0I0 cos Φ x T / 2
Average Power over a cycle is Pav = W / T
Pav = (E0I0/ 2) cos Φ
Pav = (E0/√2) (I0/ √2) cos Φ
(where cos Φ = R / Z
= R /√ [R2 + (ω L – 1/ωC)2]
is called Power Factor)
Pav = Ev Iv cos Φ
Ev
Power in AC Circuit with R:
In R, current and emf are in phase.
Φ = 0°
Pav = Ev Iv cos Φ = Ev Iv cos 0° = Ev Iv
Power in AC Circuit with L:
In L, current lags behind emf by π/2.
Φ = - π/2
Pav = Ev Iv cos (-π/2) = Ev Iv (0) = 0
Power in AC Circuit with C:
In C, current leads emf by π/2.
Φ = + π/2
Pav = Ev Iv cos (π/2) = Ev Iv (0) = 0
Note:
Power (Energy) is not dissipated in Inductor and Capacitor and hence they
find a lot of practical applications and in devices using alternating current.
Pav = Ev Iv cos Φ Wattless Current or Idle
Current:
Iv
Iv cos Φ
Iv sin Φ
Φ
90°
The component Iv cos Φ
generates power with Ev.
However, the component
Iv sin Φ does not
contribute to power along
Ev and hence power
generated is zero. This
component of current is
called wattless or idle
current.
P = Ev Iv sin Φ cos 90° = 0
L C Oscillations:
C
L
C
L
C
L
+ + + + +
- - - - -
C
L
+ + + + +
- - - - -
C
L
+ + +
- - -
C
L
+ + +
- - -
C
L
+ + +
- - -
C
L
+ + +
- - - C
L
+ + + + +
- - - - -
At t = 0, UE=Max. & UB=0 At t = T/8, UE = UB
At t =3T/8, UE = UB At t = 4T/8, UE=Max. & UB=0
At t = 2T/8, UE=0 & UB=Max.
At t =T, UE=Max. & UB=0
At t =5T/8, UE = UB
At t = 6T/8, UE=0 & UB=Max. At t =7T/8, UE = UB
q
q0
q
q0
Undamped Oscillations Damped Oscillations
If q be the charge on the capacitor at any time t and dI / dt the rate of
change of current, then
or L (d2q / dt2) + q / C = 0
or d2q / dt2 + q / (LC) = 0
Putting 1 / LC = ω2
d2q / dt2 + ω2 q = 0
The final equation represents Simple
Harmonic Electrical Oscillation with
ω as angular frequency.
So, ω = 1 / √LC
or
L dI / dt + q / C = 0
t
0
t
0
2π √LC
1
f =
Transformer:
Transformer is a device which converts lower alternating voltage at higher
current into higher alternating voltage at lower current.
S Load
Principle:
Transformer is based on
Mutual Induction.
It is the phenomenon of
inducing emf in the
secondary coil due to
change in current in the
primary coil and hence the
change in magnetic flux in
the secondary coil.
Theory:
EP = - NP dΦ / dt
ES = - NS dΦ / dt
ES / EP = NS / NP = K
(where K is called
Transformation Ratio
or Turns Ratio)
For an ideal transformer,
Output Power = Input Power
ESIS = EPIP
ES / EP = IP / IS
ES / EP = IP / IS = NS / NP
Efficiency (η):
η = ESIS / EPIP
For an ideal
transformer η
is 100%
P
Step - up Transformer: Step - down Transformer:
Load
P S P S
Load
NS > NP i.e. K > 1
ES > EP & IS < IP
NS < NP i.e. K < 1
ES < EP & IS > IP
Energy Losses in a Transformer:
1. Copper Loss: Heat is produced due to the resistance of the copper
windings of Primary and Secondary coils when current flows through
them.
This can be avoided by using thick wires for winding.
2. Flux Loss: In actual transformer coupling between Primary and Secondary
coil is not perfect. So, a certain amount of magnetic flux is wasted.
Linking can be maximised by winding the coils over one another.
3. Iron Losses:
a) Eddy Currents Losses:
When a changing magnetic flux is linked with the iron core, eddy
currents are set up which in turn produce heat and energy is wasted.
Eddy currents are reduced by using laminated core instead of a solid iron
block because in laminated core the eddy currents are confined with in
the lamination and they do not get added up to produce larger current.
In other words their paths are broken instead of continuous ones.
Solid Core Laminated Core
b) Hysteresis Loss:
When alternating current is
passed, the iron core is
magnetised and demagnetised
repeatedly over the cycles and
some energy is being lost in the
process.
4. Losses due to vibration of core: Some electrical energy is lost in the
form of mechanical energy due to vibration of the core and humming
noise due to magnetostriction effect.
This can be minimised by using suitable material with thin hysteresis loop.
A.C. Generator:
A.C. Generator or A.C. Dynamo or Alternator is a device which converts
mechanical energy into alternating current (electrical energy).
R1
R2
B1
B2
Load
R1
R2
B1
B2
Load
A.C. Generator is based on the principle of Electromagnetic Induction.
Principle:
(i) Field Magnet with poles N and S
(ii) Armature (Coil) PQRS
(iii)Slip Rings (R1 and R2)
(iv)Brushes (B1 and B2)
(v) Load
Construction:
Working:
Let the armature be rotated in such a way that the arm PQ goes down and
RS comes up from the plane of the diagram. Induced emf and hence
current is set up in the coil. By Fleming’s Right Hand Rule, the direction
of the current is PQRSR2B2B1R1P.
After half the rotation of the coil, the arm PQ comes up and RS goes down
into the plane of the diagram. By Fleming’s Right Hand Rule, the direction
of the current is PR1B1B2R2SRQP.
If one way of current is taken +ve, then the reverse current is taken –ve.
Therefore the current is said to be alternating and the corresponding wave
is sinusoidal.
Theory:
P
Q
R
S
B
θ
ω
n
Φ = N B A cos θ
At time t, with angular velocity ω,
θ = ωt (at t = 0, loop is assumed to
be perpendicular to the magnetic field
and θ = 0°)
Φ = N B A cos ωt
Differentiating w.r.t. t,
dΦ / dt = - NBAω sin ωt
E = - dΦ / dt
E = NBAω sin ωt
E = E0 sin ωt (where E0 = NBAω)
0
π 2π 3π 4π
T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T
t
π/2 3π/2 5π/2 7π/2 θ = ωt
E0
End of Alternating Currents

More Related Content

PPT
Alternating Currents Class 12
PPT
2_alternating_currents.ppt
PPT
class 12th physics (AC) alternating currents ppt
PDF
12330707_8b8f4641-a72a-483b-b1f7-22903571db2a.pdf
PPTX
7. Alternating Current.pptx and almost everything
PPTX
AC Fundamental & Single Phase AC Circuit
PDF
PHY PUC 2 Notes-Alternating current
Alternating Currents Class 12
2_alternating_currents.ppt
class 12th physics (AC) alternating currents ppt
12330707_8b8f4641-a72a-483b-b1f7-22903571db2a.pdf
7. Alternating Current.pptx and almost everything
AC Fundamental & Single Phase AC Circuit
PHY PUC 2 Notes-Alternating current

Similar to 4.alternating_currents.ppt (20)

PDF
Class 12 Physics Study Material on Alternating Current
PPT
Module1 ppt
PDF
PowerPoint Presentation.pdf
PDF
Alternating Current Lecture Introduction
PPTX
Alternating Current
PPTX
Electrical Circuits
PDF
AC Circuits.pdf
DOCX
Important notes JEE - Physics -Electromagnetic Induction Part 2
PDF
Ac circuits notes
PDF
Single phase AC circuit
PDF
Power in AC circuits.pdf
PDF
Basic Electrical Engineering- AC Circuit
PPT
ac report
PPT
Chapter32A.ppt
DOCX
AC CIRCUITS REPRESENTATION OF SINUSOIDAL WAVEFORMS, PEAK, RMS AND AVERAGE VA...
DOCX
MODULE 2: AC CIRCUITS REPRESENTATION OF SINUSOIDAL WAVEFORMS, PEAK, RMS AND A...
PDF
Ac fundamentals
PPT
presentation_chapter_2_ac_networks_1516086872_20707.ppt
PDF
Alternating current converted
PPT
AC Circuits circuit theory , network analysis.ppt
Class 12 Physics Study Material on Alternating Current
Module1 ppt
PowerPoint Presentation.pdf
Alternating Current Lecture Introduction
Alternating Current
Electrical Circuits
AC Circuits.pdf
Important notes JEE - Physics -Electromagnetic Induction Part 2
Ac circuits notes
Single phase AC circuit
Power in AC circuits.pdf
Basic Electrical Engineering- AC Circuit
ac report
Chapter32A.ppt
AC CIRCUITS REPRESENTATION OF SINUSOIDAL WAVEFORMS, PEAK, RMS AND AVERAGE VA...
MODULE 2: AC CIRCUITS REPRESENTATION OF SINUSOIDAL WAVEFORMS, PEAK, RMS AND A...
Ac fundamentals
presentation_chapter_2_ac_networks_1516086872_20707.ppt
Alternating current converted
AC Circuits circuit theory , network analysis.ppt
Ad

Recently uploaded (20)

PPT
ACCOMPLISHMENT REPOERTS AND FILE OF GRADE 12 2021.ppt
PDF
Volvo EC290C NL EC290CNL Excavator Service Repair Manual Instant Download.pdf
PPTX
laws of thermodynamics with complete explanation
PDF
intrusion control for clean steel 123.pdf
PDF
EC290C NL EC290CNL Volvo excavator specs.pdf
PDF
EC290C NL EC290CNL - Volvo Service Repair Manual.pdf
PDF
Presentation.pdf ...............gjtn....tdubsr..........
PDF
Volvo EC290C NL EC290CNL excavator weight.pdf
PPTX
Independence_Day_Patriotic theme (1).pptx
PDF
Caterpillar Cat 315C Excavator (Prefix CJC) Service Repair Manual Instant Dow...
PPTX
Transmission system. Describe construction & working of varius automobile sys...
PDF
industrial engineering and safety system
PPTX
Zeem: Transition Your Fleet, Seamlessly by Margaret Boelter
PDF
6. Chapter Twenty_Managing Mass Communications Advertising Sales Promotions E...
PDF
3-REasdfghjkl;[poiunvnvncncn-Process.pdf
PDF
LB95 New Holland Service Repair Manual.pdf
PDF
Volvo EC20C Excavator Step-by-step Maintenance Instructions pdf
PPTX
Robot_ppt_YRG[1] [Read-Only]bestppt.pptx
PDF
Caterpillar Cat 315C Excavator (Prefix ANF) Service Repair Manual Instant Dow...
PDF
RPL-ASDC PPT PROGRAM NSDC GOVT SKILLS INDIA
ACCOMPLISHMENT REPOERTS AND FILE OF GRADE 12 2021.ppt
Volvo EC290C NL EC290CNL Excavator Service Repair Manual Instant Download.pdf
laws of thermodynamics with complete explanation
intrusion control for clean steel 123.pdf
EC290C NL EC290CNL Volvo excavator specs.pdf
EC290C NL EC290CNL - Volvo Service Repair Manual.pdf
Presentation.pdf ...............gjtn....tdubsr..........
Volvo EC290C NL EC290CNL excavator weight.pdf
Independence_Day_Patriotic theme (1).pptx
Caterpillar Cat 315C Excavator (Prefix CJC) Service Repair Manual Instant Dow...
Transmission system. Describe construction & working of varius automobile sys...
industrial engineering and safety system
Zeem: Transition Your Fleet, Seamlessly by Margaret Boelter
6. Chapter Twenty_Managing Mass Communications Advertising Sales Promotions E...
3-REasdfghjkl;[poiunvnvncncn-Process.pdf
LB95 New Holland Service Repair Manual.pdf
Volvo EC20C Excavator Step-by-step Maintenance Instructions pdf
Robot_ppt_YRG[1] [Read-Only]bestppt.pptx
Caterpillar Cat 315C Excavator (Prefix ANF) Service Repair Manual Instant Dow...
RPL-ASDC PPT PROGRAM NSDC GOVT SKILLS INDIA
Ad

4.alternating_currents.ppt

  • 1. ALTERNATING CURRENTS 1. Alternating EMF and Current 2. Average or Mean Value of Alternating EMF and Current 3. Root Mean Square Value of Alternating EMF and Current 4. A C Circuit with Resistor 5. A C Circuit with Inductor 6. A C Circuit with Capacitor 7. A C Circuit with Series LCR – Resonance and Q-Factor 8. Graphical Relation between Frequency vs XL, XC 9. Power in LCR A C Circuit 10.Watt-less Current 11.L C Oscillations 12.Transformer 13.A.C. Generator Created by C. Mani, Principal, K V No.1, AFS, Jalahalli West, Bangalore
  • 2. Alternating emf: Alternating emf is that emf which continuously changes in magnitude and periodically reverses its direction. Alternating Current: Alternating current is that current which continuously changes in magnitude and periodically reverses its direction. T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T t 0 π 2π 3π 4π π/2 3π/2 5π/2 7π/2 θ = ωt E ,I E0 I0 E = E0 sin ωt I = I0 sin ωt E, I – Instantaneous value of emf and current E0, I0 – Peak or maximum value or amplitude of emf and current ω – Angular frequency t – Instantaneous time ωt – Phase T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T t 0 π 2π 3π 4π π/2 3π/2 5π/2 7π/2 θ = ωt E ,I E0 I0 E = E0 cos ωt I = I0 cos ωt Symbol of AC Source
  • 3. Average or Mean Value of Alternating Current: Average or Mean value of alternating current over half cycle is that steady current which will send the same amount of charge in a circuit in the time of half cycle as is sent by the given alternating current in the same circuit in the same time. dq = I dt = I0 sin ωt dt q = ∫ I0 sin ωt dt 0 T/2 q = 2 I0 / ω = 2 I0 T / 2π = I0 T / π Mean Value of AC, Im = Iav = q / (T/2) Im = Iav = 2 I0 / π = 0.637 I0 = 63.7 % I0 Average or Mean Value of Alternating emf: Em = Eav = 2 E0 / π = 0.637 E0 = 63.7 % E0 Note: Average or Mean value of alternating current or emf is zero over a cycle as the + ve and – ve values get cancelled.
  • 4. Root Mean Square or Virtual or Effective Value of Alternating Current: Root Mean Square (rms) value of alternating current is that steady current which would produce the same heat in a given resistance in a given time as is produced by the given alternating current in the same resistance in the same time. dH = I2R dt = I0 2 R sin2 ωt dt H = ∫ I0 2 R sin2 ωt dt 0 T H = I0 2 RT / 2 If Iv be the virtual value of AC, then Iv = Irms = Ieff = I0 / √2 = 0.707 I0 = 70.7 % I0 Root Mean Square or Virtual or Effective Value of Alternating emf: Ev = Erms = Eeff = E0 / √2 = 0.707 E0 = 70.7 % E0 Note: 1. Root Mean Square value of alternating current or emf can be calculated over any period of the cycle since it is based on the heat energy produced. 2. Do not use the above formulae if the time interval under the consideration is less than one period. (After integration, ω is replaced with 2 π / T) H = Iv 2 RT
  • 5. 0 π 2π 3π 4π T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T t π/2 3π/2 5π/2 7π/2 θ = ωt E0 Ev Em Relative Values Peak, Virtual and Mean Values of Alternating emf: Em = Eav = 0.637 E0 Ev = Erms = Eeff = 0.707 E0 Tips: 1. The given values of alternating emf and current are virtual values unless otherwise specified. i.e. 230 V AC means Ev = Erms = Eeff = 230 V 2. AC Ammeter and AC Voltmeter read the rms values of alternating current and voltage respectively. They are called as ‘hot wire meters’. 3. The scale of DC meters is linearly graduated where as the scale of AC meters is not evenly graduated because H α I2
  • 6. AC Circuit with a Pure Resistor: R E = E0 sin ωt E = E0 sin ωt I = E / R = (E0 / R) sin ωt I = I0 sin ωt (where I0 = E0 / R and R = E0 / I0) Emf and current are in same phase. T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T t 0 π 2π 3π 4π π/2 3π/2 5π/2 7π/2 θ = ωt E ,I E0 I0 E = E0 sin ωt I = I0 sin ωt E0 I0 ωt y x 0
  • 7. x 0 AC Circuit with a Pure Inductor: L E = E0 sin ωt E = E0 sin ωt T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T t π 2π 3π 4π π/2 3π/2 5π/2 7π/2 θ = ωt E ,I E0 I0 E = E0 sin ωt I = I0 sin (ωt - π / 2) E0 ωt Induced emf in the inductor is - L (dI / dt) In order to maintain the flow of current, the applied emf must be equal and opposite to the induced emf. E = L (dI / dt) E0 sin ωt = L (dI / dt) dI = (E0 / L) sin ωt dt I = ∫ (E0 / L) sin ωt dt I = (E0 / ωL) ( - cos ωt ) I = I0 sin (ωt - π / 2) (where I0 = E0 / ωL and XL = ωL = E0 / I0) XL is Inductive Reactance. Its SI unit is ohm. I0 y Current lags behind emf by π/2 rad. 0 π/2
  • 8. y AC Circuit with a Capacitor: E = E0 sin ωt E = E0 sin ωt T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T t 0 π 2π 3π 4π π/2 3π/2 5π/2 7π/2 θ = ωt E ,I E0 I0 E = E0 sin ωt I = I0 sin (ωt + π / 2) E0 ωt q = CE = CE0 sin ωt I = dq / dt = (d / dt) [CE0 sin ωt] I = [E0 / (1 / ωC)] ( cos ωt ) I = I0 sin (ωt + π / 2) (where I0 = E0 / (1 / ωC) and XC = 1 / ωC = E0 / I0) XC is Capacitive Reactance. Its SI unit is ohm. I0 π/2 x 0 Current leads the emf by π/2 radians. C
  • 9. Variation of XL with Frequency: I0 = E0 / ωL and XL = ωL XL is Inductive Reactance and ω = 2π f XL = 2π f L i.e. XL α f XL f 0 Variation of XC with Frequency: I0 = E0 / (1/ωC) and XC = 1 / ωC XC is Inductive Reactance and ω = 2π f XC = 1 / 2π f C i.e. XC α 1 / f XC f 0 TIPS: 1) Inductance (L) can not decrease Direct Current. It can only decrease Alternating Current. 2) Capacitance (C) allows AC to flow through it but blocks DC.
  • 10. AC Circuit with L, C, R in Series Combination: E = E0 sin ωt C L R VL VC VR 1) In R, current and voltage are in phase. 2) In L, current lags behind voltage by π/2 3) In C, current leads the voltage by π/2 VR VL VC I π/2 π/2 - VC VL VR I π/2 VL - VC VR I E Φ E = √ [VR 2 + (VL – VC)2] The applied emf appears as Voltage drops VR, VL and VC across R, L and C respectively. E = √ [VR 2 + (VL – VC)2] I = E √ [R2 + (XL – XC)2] Z = √ [R2 + (XL – XC)2] Z = √ [R2 + (ω L – 1/ωC)2] tan Φ = XL – XC R tan Φ = ω L – 1/ωC R or 0 VC
  • 11. or tan Φ = XL – XC R tan Φ = ω L – 1/ωC R Special Cases: Case I: When XL > XC i.e. ω L > 1/ωC, tan Φ = +ve or Φ is +ve The current lags behind the emf by phase angle Φ and the LCR circuit is inductance - dominated circuit. Case II: When XL < XC i.e. ω L < 1/ωC, tan Φ = -ve or Φ is -ve The current leads the emf by phase angle Φ and the LCR circuit is capacitance - dominated circuit. Case III: When XL = XC i.e. ω L = 1/ωC, tan Φ = 0 or Φ is 0° The current and the emf are in same phase. The impedance does not depend on the frequency of the applied emf. LCR circuit behaves like a purely resistive circuit.
  • 12. Resonance in AC Circuit with L, C, R: When XL = XC i.e. ω L = 1/ωC, tan Φ = 0 or Φ is 0° and Z = √ [R2 + (ω L – 1/ωC)2] becomes Zmin = R and I0max = E / R i.e. The impedance offered by the circuit is minimum and the current is maximum. This condition is called resonant condition of LCR circuit and the frequency is called resonant frequency. At resonant angular frequency ωr, ωr L = 1/ωrC or ωr = 1 / √LC or fr = 1 / (2π √LC) ωr I0max ω 0 R1 R2 R3 I0 I0max / √2 ωr - ∆ ω ωr + ∆ ω Band width = 2 ∆ ω Quality factor (Q – factor) is defined as the ratio of resonant frequency to band width. Q = ωr / 2 ∆ ω or Q = ωr L / R or Q = 1 / ωrCR Q = VL / VR or Q = VC / VR Resonant Curve & Q - Factor: It can also be defined as the ratio of potential drop across either the inductance or the capacitance to the potential drop across the resistance. R1 < R2 < R3
  • 13. Power in AC Circuit with L, C, R: Instantaneous Power = E I = E0 I0 sin ωt sin (ωt + Φ) = E0 I0 [sin2 ωt cosΦ + sin ωt cosωt cosΦ] E = E0 sin ωt I = I0 sin (ωt + Φ) (where Φ is the phase angle between emf and current) If the instantaneous power is assumed to be constant for an infinitesimally small time dt, then the work done is dW = E0 I0 [sin2 ωt cosΦ + sin ωt cosωt cosΦ] Work done over a complete cycle is W = ∫ E0 I0 [sin2 ωt cosΦ + sin ωt cosωt cosΦ] dt 0 T W = E0I0 cos Φ x T / 2 Average Power over a cycle is Pav = W / T Pav = (E0I0/ 2) cos Φ Pav = (E0/√2) (I0/ √2) cos Φ (where cos Φ = R / Z = R /√ [R2 + (ω L – 1/ωC)2] is called Power Factor) Pav = Ev Iv cos Φ
  • 14. Ev Power in AC Circuit with R: In R, current and emf are in phase. Φ = 0° Pav = Ev Iv cos Φ = Ev Iv cos 0° = Ev Iv Power in AC Circuit with L: In L, current lags behind emf by π/2. Φ = - π/2 Pav = Ev Iv cos (-π/2) = Ev Iv (0) = 0 Power in AC Circuit with C: In C, current leads emf by π/2. Φ = + π/2 Pav = Ev Iv cos (π/2) = Ev Iv (0) = 0 Note: Power (Energy) is not dissipated in Inductor and Capacitor and hence they find a lot of practical applications and in devices using alternating current. Pav = Ev Iv cos Φ Wattless Current or Idle Current: Iv Iv cos Φ Iv sin Φ Φ 90° The component Iv cos Φ generates power with Ev. However, the component Iv sin Φ does not contribute to power along Ev and hence power generated is zero. This component of current is called wattless or idle current. P = Ev Iv sin Φ cos 90° = 0
  • 15. L C Oscillations: C L C L C L + + + + + - - - - - C L + + + + + - - - - - C L + + + - - - C L + + + - - - C L + + + - - - C L + + + - - - C L + + + + + - - - - - At t = 0, UE=Max. & UB=0 At t = T/8, UE = UB At t =3T/8, UE = UB At t = 4T/8, UE=Max. & UB=0 At t = 2T/8, UE=0 & UB=Max. At t =T, UE=Max. & UB=0 At t =5T/8, UE = UB At t = 6T/8, UE=0 & UB=Max. At t =7T/8, UE = UB
  • 16. q q0 q q0 Undamped Oscillations Damped Oscillations If q be the charge on the capacitor at any time t and dI / dt the rate of change of current, then or L (d2q / dt2) + q / C = 0 or d2q / dt2 + q / (LC) = 0 Putting 1 / LC = ω2 d2q / dt2 + ω2 q = 0 The final equation represents Simple Harmonic Electrical Oscillation with ω as angular frequency. So, ω = 1 / √LC or L dI / dt + q / C = 0 t 0 t 0 2π √LC 1 f =
  • 17. Transformer: Transformer is a device which converts lower alternating voltage at higher current into higher alternating voltage at lower current. S Load Principle: Transformer is based on Mutual Induction. It is the phenomenon of inducing emf in the secondary coil due to change in current in the primary coil and hence the change in magnetic flux in the secondary coil. Theory: EP = - NP dΦ / dt ES = - NS dΦ / dt ES / EP = NS / NP = K (where K is called Transformation Ratio or Turns Ratio) For an ideal transformer, Output Power = Input Power ESIS = EPIP ES / EP = IP / IS ES / EP = IP / IS = NS / NP Efficiency (η): η = ESIS / EPIP For an ideal transformer η is 100% P
  • 18. Step - up Transformer: Step - down Transformer: Load P S P S Load NS > NP i.e. K > 1 ES > EP & IS < IP NS < NP i.e. K < 1 ES < EP & IS > IP Energy Losses in a Transformer: 1. Copper Loss: Heat is produced due to the resistance of the copper windings of Primary and Secondary coils when current flows through them. This can be avoided by using thick wires for winding. 2. Flux Loss: In actual transformer coupling between Primary and Secondary coil is not perfect. So, a certain amount of magnetic flux is wasted. Linking can be maximised by winding the coils over one another.
  • 19. 3. Iron Losses: a) Eddy Currents Losses: When a changing magnetic flux is linked with the iron core, eddy currents are set up which in turn produce heat and energy is wasted. Eddy currents are reduced by using laminated core instead of a solid iron block because in laminated core the eddy currents are confined with in the lamination and they do not get added up to produce larger current. In other words their paths are broken instead of continuous ones. Solid Core Laminated Core b) Hysteresis Loss: When alternating current is passed, the iron core is magnetised and demagnetised repeatedly over the cycles and some energy is being lost in the process. 4. Losses due to vibration of core: Some electrical energy is lost in the form of mechanical energy due to vibration of the core and humming noise due to magnetostriction effect. This can be minimised by using suitable material with thin hysteresis loop.
  • 20. A.C. Generator: A.C. Generator or A.C. Dynamo or Alternator is a device which converts mechanical energy into alternating current (electrical energy). R1 R2 B1 B2 Load R1 R2 B1 B2 Load
  • 21. A.C. Generator is based on the principle of Electromagnetic Induction. Principle: (i) Field Magnet with poles N and S (ii) Armature (Coil) PQRS (iii)Slip Rings (R1 and R2) (iv)Brushes (B1 and B2) (v) Load Construction: Working: Let the armature be rotated in such a way that the arm PQ goes down and RS comes up from the plane of the diagram. Induced emf and hence current is set up in the coil. By Fleming’s Right Hand Rule, the direction of the current is PQRSR2B2B1R1P. After half the rotation of the coil, the arm PQ comes up and RS goes down into the plane of the diagram. By Fleming’s Right Hand Rule, the direction of the current is PR1B1B2R2SRQP. If one way of current is taken +ve, then the reverse current is taken –ve. Therefore the current is said to be alternating and the corresponding wave is sinusoidal.
  • 22. Theory: P Q R S B θ ω n Φ = N B A cos θ At time t, with angular velocity ω, θ = ωt (at t = 0, loop is assumed to be perpendicular to the magnetic field and θ = 0°) Φ = N B A cos ωt Differentiating w.r.t. t, dΦ / dt = - NBAω sin ωt E = - dΦ / dt E = NBAω sin ωt E = E0 sin ωt (where E0 = NBAω) 0 π 2π 3π 4π T/4 T/2 3T/4 T 5T/4 3T/2 7T/4 2T t π/2 3π/2 5π/2 7π/2 θ = ωt E0 End of Alternating Currents