SlideShare a Scribd company logo
Distribution Components
RDW2 Series Intelligent Universal
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 1600, 2500, 4000, 6300A
Rated current: 200A~6300A
Rated operating voltage: AC 400V, AC 690V
Number of pole: 3P, 4P
Breaking capacity: 25kA~125kA
Installation mode: Fixed type, Drawer type
RDW1 Series Intelligent Universal
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 630, 1000, 2000, 3200, 4000, 6300A
Rated current: 100A~6300A
Rated operating voltage: AC 400V
Number of pole: 3P, 4P
Breaking capacity: 42kA~120kA
Installation mode: Fixed type, Drawer type
RDW17 Series Intelligent Universal
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 1600, 1605, 2500, 2505, 3200, 3205A
Rated current: 630A~5000A
Rated operating voltage: AC 380V, AC 660V
Number of pole: 3P, 4P
Breaking capacity: 50kA~80kA
Installation mode: Fixed type, Drawer type
DW15 Series Intelligent Universal
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 630, 1600, 2500, 4000, 6300A
Rated current: 200A~6300A
Rated operating voltage: AC 380V
Number of pole: 3P
Breaking capacity: 20kA~80kA
Installation mode: Fixed type, Drawer type (only for 630 type)
DW16 Series Intelligent Universal
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 630, 2000, 4000A
Rated current: 100A~4000A
Rated operating voltage: AC 400V
Number of pole: 3P
Breaking capacity: 20kA~80kA
RDM1 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 63, 100, 250, 400, 630, 800, 1250A
Rated current: 10A~1250A
Rated operating voltage: AC 400V, AC 690V
Number of pole: 2P (only for 100, 250 type), 3P, 4P
Breaking capacity: 25kA~100kA
RDM1E Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 63, 100, 250, 400, 630, 800, 1250A
Rated current: 10A~1250A
Rated operating voltage: AC 400V, AC 690V
Number of pole: 3P, 4P
Breaking capacity: 25kA~100kA
RDM11 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 100, 160, 250, 400, 630A
Rated current: 16A~630A
Rated operating voltage: AC 690V
Number of pole: 3P, 4P
Breaking capacity: 25kA~50kA
www.peopleelectric.com 016
RDM6 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 125, 160, 250, 400, 630, 800, 1250, 1600A
Rated current: 12.5A~1600A
Rated operating voltage: AC 400V
Number of pole: 3P, 4P
Breaking capacity: 25kA~65kA
DZ20 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 100, 225, 400, 630, 1250, 2000A
Rated current: 16A~2000A
Rated operating voltage: AC 380V
Number of pole: 3P, 4P
Breaking capacity: 18kA~100kA
RDM108 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 20, 32, 63A
Rated current: 0.16A~63A
Rated operating voltage: AC 660V
Number of pole: 3P
Breaking capacity: 1.5kA~22kA
DZ15 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 40, 100A
Rated current: 6A~100A
Rated operating voltage: AC 220V, AC 380V
Number of pole: 1P, 2P, 3P, 4P
Breaking capacity: 3kA~5kA
RDM10 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 100, 160, 400, 630A
Rated current: 16A~630A
Rated operating voltage: AC 400V
Number of pole: 3P
Breaking capacity: 7.5kA~15kA
RDM1L Series Residual Operated
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 100, 225, 400, 800A
Rated current: 10A~800A
Rated operating voltage: AC 400V
Number of pole: 2P (only for 100M, 225L, 225M type),
3P, 4P
Breaking capacity: 35kA~100kA
Residual operated current: 30/100/300/500/1000mA
RDL20 Series Residual Operated
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 160, 250, 400, 630A
Rated current: 50A~630A
Rated operating voltage: AC 380V
Number of pole: 3P +N
Breaking capacity: 12kA~30kA
Residual operated current: 100/200/300/500mA
RDM30LE Series Intelligent Leakage
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 100, 250, 400, 630A
Rated current: 63A~630A
Rated operating voltage: AC 380V
Number of pole: 3P +N
Breaking capacity: 6kA~36kA
Residual operated current: 100/300/500/1000mA
017 www.peopleelectric.com
Distribution Components
DZL25 Series Leakage Circuit Breaker
Confirms to: IEC60947-2
Frame size: 100, 250A
Rated current: 40A~250A
Rated operating voltage: AC 380V
Number of pole: 4P
Breaking capacity: 6kA, 10kA
Residual operated current: 30/50/100/200/300/500mA
DZ15LE Series Leakage Circuit Breaker
Confirms to: IEC60947-2
Frame size: 40, 100A
Rated current: 6A~100A
Rated operating voltage: AC 220V, AC 380V
Number of pole: 2P, 3P, 4P
Breaking capacity: 3kA, 5kA
Residual operated current: 30/50/75/100mA
RDM10L Series Leakage Circuit Breaker
Confirms to: IEC60947-2
Frame size: 100, 250A
Rated current: 40A~250A
Rated operating voltage: AC 380V
Number of pole: 4P
Breaking capacity: 6kA, 10kA
Residual operated current: 75/100/150/200/300mA
RDL18 Series Leakage Circuit Breaker
Confirms to: IEC60947-2
Frame size: 20, 32A
Rated current: 10A~32A
Rated operating voltage: AC 220V
Number of pole: 2P
Breaking capacity: 500A
Residual operated current: 30mA
RDQH Series Dual Power Supply
Automatic Transfer Switch
Confirms to: GB/T14048.11
Frame size: 63, 100, 225, 400, 630, 800, 1250, 1600A
Rated current: 10A~1600A
Rated operating voltage: AC 400V
Number of pole: 3P, 4P
Breaking capacity: 5kA~35kA
ATS grade: CB class
RDQ1 Series Dual Power Supply
Automatic Transfer Switch
Confirms to: GB/T14048.11
Frame size: 63A
Rated current: 6A~63A
Rated operating voltage: AC 220V, AC 400V
Number of pole: 2P, 3P, 4P
Breaking capacity: 5kA
ATS grade: CB class
RDWQ2 Series Dual Power Supply
Automatic Transfer Switch
Confirms to: GB/T14048.11
Frame size: 1000, 2000, 3200, 4000, 6300A
Rated current: 200A~6300A
Rated operating voltage: AC 400V
Number of pole: 3P, 4P
Breaking capacity: 10kA~100kA
ATS grade: CB class
RDQ6 Series Dual Power Supply
Automatic Transfer Switch
Confirms to: GB/T14048.11
Rated current: 63A~3150A
Rated operating voltage: AC 400V
Number of pole: 2P, 3P, 4P
Breaking capacity: 5kA~80kA
ATS grade: PC class
www.peopleelectric.com 018
RDH5D Series Dual Power Supply
Automatic Transfer Switch
Confirms to: GB/T14048.11
Rated current: 32A~3200A
Rated operating voltage: AC 400V
Number of pole: 3P, 4P
Breaking capacity: 5kA~80kA
ATS grade: PC class
HD, HS Series Open Type Knife Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 200, 400, 600, 1000, 1500, 2000, 3000A
Rated current: 100~3000A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated short-time withstand current: 6kA~50kA
Number of pole: 1P, 2P, 3P, 4P
HS11FH Series Protective Open Type
Knife Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 100, 200, 400A
Rated current: 100~400A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated short-time withstand current: 6kA~20kA
Number of pole: 3P, 4P
HD11F Series Open Type
Knife Switch
Mistake-proof
Confirms to: GB14048.3, IEC60947-3
Frame size: 100, 200, 400A, 600, 1000, 1500A
Rated current: 100~1500A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated short-time withstand current: 6kA~40kA
Number of pole: 3P, 4P
HD11FH Series Protective Open Type
Knife Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 100, 200, 400A
Rated current: 100~400A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated short-time withstand current: 6kA~20kA
Number of pole: 3P, 4P
HR3 Series Fuse Knife Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 100, 200, 400, 600, 1000A
Rated current: 100~1000A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Number of pole: 3P
RDHG1 Series Fuse Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Rated current: 32~63A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Electrical life: 200~600 times
Number of pole: 3P
HR18 Series Fuse Knife Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 160, 250, 400, 630A
Rated current: 160~630A
Rated operating voltage: AC 400V, AC 660V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Electrical life: 200~600 times
Number of pole: 3P
019 www.peopleelectric.com
Distribution Components
RDHG2B Series Strip Type Fuse
Switch Disconnector
Confirms to: GB14048.3, IEC60947-3
Frame size: 160, 250, 400, 630A
Rated current: 160~630A
Rated operating voltage: AC 400V, AC 690V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Electrical life: 200~600 times
Number of pole: 3P
HR5 Series Fuse Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 160, 250, 400, 630A
Rated operating voltage: AC 380V, AC 660V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50~100kA
Number of pole: 3P
HR6 Series Fuse Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 160, 250, 400, 630A
Rated operating voltage: AC 380V, AC 660V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50~100kA
Number of pole: 3P
HR17B Series Fuse Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 40, 60, 160, 250, 400, 630A
Rated operating current: 40~630A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Electrical life: 200~600 times
Number of pole: 2P, 3P, 4P
RDH5 Series Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 63, 100, 125, 160, 200, 400, 630, 1000,
1250, 1600, 2000, 2500, 3200A
Rated operating current: 63~3200A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Operation mode: operation inside of cabinet, operation
outside of cabinet
Number of pole: 3P, 4P
RDH5R Series Isolation Switch Fuse
Group
Confirms to: GB14048.3, IEC60947-3
Frame size: 160, 400, 630A
Rated operating current: 160~630A
Rated operating voltage: AC 380V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Number of pole: 2P, 3P, 4P
HH15 Series Isolation Switch Fuse
Group
Confirms to: GB14048.3, IEC60947-3
Rated operating current: (QSA) 63~800A
(QA) 125~1000A
(QP) 250~3150A
Rated operating voltage: AC 380V, AC 660V,
Rated limit short-circuit current: 50kA
Operation mode: operation outside of cabinet
Number of pole: 3P
JDW2 Series Low Voltage Outdoor
Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Rated operating current: 200~800A
Rated operating voltage: AC 500V
www.peopleelectric.com 020
HH3 Series Load Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 60, 100, 150, 200, 300, 400, 600A
Rated current: 60~600A
Rated voltage: AC 380V
Rated limit short-circuit current: 50kA
Number of pole: 3P
HH4 Series Load Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 15, 30, 60, 100A
Rated current: 15~100A
Rated voltage: AC 380V
Rated limit short-circuit current: 50kA
Number of pole: 3P
HK2 Series Load Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 16, 32, 63, 75A
Rated current: 16~75A
Rated voltage: AC 220V, AC 380V
Rated limit short-circuit current: 50kA
Number of pole: 2P, 3P
RDT16 Series Powder Filled Cartridge
Knife Type Contact Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 10~1250A
Rated voltage: Up to AC 690V
Rated breaking capacity: 120kA
Scope of breaking and usage category: gG type and aM
type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RDF16 Series Powder Filled Cartridge
Knife Type Contact Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 16~630A
Rated voltage: Up to AC 690V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RL1 Series Screw Type Fuse
Confirms to: GB/T13539.3, IEC60269-3
Rated current: 2~200A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RT18, HG30 Series Powder Filled
Cartridge Cylindrical Cape Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 2~125A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
and aM type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RT19 Series Powder Filled Cartridge
Cylindrical Cape Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 2~100A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
and aM type
It is mainly used for electric circuit’s over-load and
short-circuit protection
021 www.peopleelectric.com
Distribution Components
RT14 Series Powder Filled Cartridge
Cylindrical Cape Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 2~63A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RT0 Series Powder Filled Cartridge
Knife Type Contact Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 10~1000A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RS0, RS3 Series Fast Fuse
Confirms to: GB/T13539.4, IEC60269-4
Rated current: (RS 0) 10A~1250A
(RS 0) 10A~1000A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: aR type
It is mainly used for the protection of semiconductor
crystal tube and its complete equipment
NGT Series Fast Fuse
Confirms to: GB/T13539.4, IEC60269-4
Rated current: 25~630A
Rated voltage: AC 380V, 660V, 800V, 1000V
Rated breaking capacity: 100kA
Scope of breaking and usage category: aR type
It is mainly used for the protection of semiconductor
crystal tube and its complete equipment
BSMJ (Y), BZMJ (Y) Series Auto-
Healing Low Voltage Shunt Capacitor
Confirms to: GB/T12847, IEC831-1
Rated operating voltage: AC 250V, AC 400V, AC 450V
AC 525V, AC 690V, AC 750V
Rated capacity: 1-50kvar
It can be used with CJ 19, combination switch
RD-ZM Series Intelligent Low Voltage
Capacitor
Confirms to: GB/T29312
Rated operating voltage: AC 380V/ 220V
Rated capacity: total compensation of 5~40kvar;
separated compensation of 5~20kvar
It can compensation in situ by one machine, and also
can networking to intelligently automatic operation by
multi-machines, and no need to add reactive compensation
controller to control.
JKW5C Series Low Voltage Reactive
Compensation Controller
Confirms to: JB/T 9663
Rated operating voltage: AC 220V/ 380V
Rated current: AC 0~5A
Capacity of contacts: AC 220V 5A
Controlled circuit No.: 1~12 circuits
Protection grade: IP40
JKW6C Series Low Voltage Reactive
Compensation Controller
Confirms to: JB/T 9663
Rated operating voltage: AC 220V/ 380V
Rated current: AC 0~5A
Capacity of contacts: AC 220V 5A
Controlled circuit No.: 1~12 circuits
Protection grade: IP40
www.peopleelectric.com 022
JKL6C, JKL6B Series Low Voltage
Reactive Compensation Controller
Confirms to: JB/T 9663
Rated operating voltage: AC 220V/ 380V
Rated current: AC 0~5A
Capacity of contacts: AC 220V 5A
Controlled circuit No.: 1~12 circuits
Protection grade: IP 40
JKG2B, JKW5B Series Low Voltage
Reactive Compensation Controller
Confirms to: JB/T 9663
Rated operating voltage: AC 220V/ 380V
Rated current: AC 0~5A
Capacity of contacts: AC 220V 5A
Controlled circuit No.: 1~12 circuits
Protection grade: IP 40
JKWR Series Low Voltage Reactive
Compensation Controller
Confirms to: JB/T 9663
Rated operating voltage: AC 220V
Rated current: AC 0~5A
Capacity of contacts: AC 220V 7A
Controlled circuit No.: 1~13 circuits
Protection grade: IP 40
DB Series Distribution Box
JXF Series Outdoor Distribution
Box Enclosure
Rated voltage: 220/380V
Rated current: 125A
Installation: Surface mounted
Protection grade: Ip65
Height: 250; 300; 400; 500; 600; 800; 1000; 1200mm, etc.
Width: 200; 250; 300; 400; 500; 600; 1000mm, etc.
Depth: 150; 200; 250; 300mm, etc.
Modules: 4, 6, 8, 12, 18, 24, 34 ways
Installation: Surface mounting, Flush mounting
Material: Plastic, Metal
Protection grade: IP40
023 www.peopleelectric.com
Distribution Components

More Related Content

PDF
Catalogue thiet bi dien abb rccb rcbo abb-dienhathe.vn
PDF
Catalogue mccb doi moi cua hang h yundai
PDF
ABB Medium Voltage MV Surge Arresters - AC & DC Surge Arresters & Protection...
PDF
Iskra Low Voltage Switchgear
PDF
Pfiserer HV Connex Surge Arresters - Sizes 4 (72.5kV) & 5-S (145 kV)
PDF
Delta DIN Rail Power Supply Brochure (September 2014)
PDF
ABB Low Voltage LV Surge Arresters - ABB LOVOS 5 and LOVOS 10 Surge Arresters
PDF
ABB POLIM-C..N High Voltage Surge Arresters AC up to 7.5 kV - AC Surge Arrest...
Catalogue thiet bi dien abb rccb rcbo abb-dienhathe.vn
Catalogue mccb doi moi cua hang h yundai
ABB Medium Voltage MV Surge Arresters - AC & DC Surge Arresters & Protection...
Iskra Low Voltage Switchgear
Pfiserer HV Connex Surge Arresters - Sizes 4 (72.5kV) & 5-S (145 kV)
Delta DIN Rail Power Supply Brochure (September 2014)
ABB Low Voltage LV Surge Arresters - ABB LOVOS 5 and LOVOS 10 Surge Arresters
ABB POLIM-C..N High Voltage Surge Arresters AC up to 7.5 kV - AC Surge Arrest...

What's hot (20)

PDF
ABB IEC Indoor Vacuum Contactors VSC - Medium Voltage Vacuum Contactors
PDF
Esv 300 sxxxst-2017060905595765811.pdf
PDF
Catalog terminal Idec
PDF
Catalog ACB (Air Circuit Breakers) BT3 sereis
PDF
Nexans Euromold Bushings 800 Amps 12kV - Nexans Euromold 600TBC
PDF
ABB Contactors - 4 Pole Contactors ABB AF09 AF09Z (AC DC) Contactors
PDF
Fcs capacitor switch
PDF
Air Circuit Breakers, 1600 to 6300A BT3 Series
PDF
ABB POLIM-C..LB Medium Voltage Surge Arresters AC up to 5kV - AC Surge Arrest...
PDF
LS Circuit Breaker Catalogue
PDF
Original Logic IC SN74LVC14A SN54LVC14A 74LVC14A 54LVC14A SOP-14 New Texas In...
PDF
Abb low voltage lv capacitors, abb clmd
PPT
ABB LOVOS Low Voltage Surge Arresters Presentation - Surge Arresters, Plugs &...
PDF
Catalog bộ nguồn PS5R IDEC mới nhất 2019
PDF
Color television chassis cn 001 g
PDF
Catalogue MCB Fuji- Miniature Circuit Breaker Fuji - Beeteco.com
PDF
Catalog hmi idec
PDF
Catalog ls mcb bkn-bkh_dienhathe.vn
PDF
Cataloge schneider catalogue schneider-dienhathe.vn
ABB IEC Indoor Vacuum Contactors VSC - Medium Voltage Vacuum Contactors
Esv 300 sxxxst-2017060905595765811.pdf
Catalog terminal Idec
Catalog ACB (Air Circuit Breakers) BT3 sereis
Nexans Euromold Bushings 800 Amps 12kV - Nexans Euromold 600TBC
ABB Contactors - 4 Pole Contactors ABB AF09 AF09Z (AC DC) Contactors
Fcs capacitor switch
Air Circuit Breakers, 1600 to 6300A BT3 Series
ABB POLIM-C..LB Medium Voltage Surge Arresters AC up to 5kV - AC Surge Arrest...
LS Circuit Breaker Catalogue
Original Logic IC SN74LVC14A SN54LVC14A 74LVC14A 54LVC14A SOP-14 New Texas In...
Abb low voltage lv capacitors, abb clmd
ABB LOVOS Low Voltage Surge Arresters Presentation - Surge Arresters, Plugs &...
Catalog bộ nguồn PS5R IDEC mới nhất 2019
Color television chassis cn 001 g
Catalogue MCB Fuji- Miniature Circuit Breaker Fuji - Beeteco.com
Catalog hmi idec
Catalog ls mcb bkn-bkh_dienhathe.vn
Cataloge schneider catalogue schneider-dienhathe.vn
Ad

Similar to 4-Distribution Components (20)

PDF
5-Terminal Components
PDF
Molded Case Circuit Breakers BX Series
PDF
2-Complete Equipment
PDF
SG104136BEN_B07_Brochure_UR6-10-15 T_0415
PDF
Motor Starter One Source
PDF
Renewable energy
PDF
Renewable energy
PDF
Low voltage circuit breakers & contactors general leaflet ls
PDF
Cataloge schneider catalogue schneider
PDF
Cataloge schneider catalogue schneider
PDF
Cataloge schneider catalogue schneider
PDF
SCHNEIDER ELECTRIC ~ AZZAN AL BADI TRADING ~ SOHAR ~ OMAN
PDF
CHiNT Price List LV Pakistan
PDF
Catalog MCCB dòng BW0 Fuji Electric mới nhất 2019
PDF
Presentation smart city presentation by cs electric (4)
PPTX
Zaman associates product presentation
PDF
Catalogue ACB BT3 - Air Circuit Breaker BT3 Fuji - Beeteco.com
PDF
Bh bv din series dienhathe.org
5-Terminal Components
Molded Case Circuit Breakers BX Series
2-Complete Equipment
SG104136BEN_B07_Brochure_UR6-10-15 T_0415
Motor Starter One Source
Renewable energy
Renewable energy
Low voltage circuit breakers & contactors general leaflet ls
Cataloge schneider catalogue schneider
Cataloge schneider catalogue schneider
Cataloge schneider catalogue schneider
SCHNEIDER ELECTRIC ~ AZZAN AL BADI TRADING ~ SOHAR ~ OMAN
CHiNT Price List LV Pakistan
Catalog MCCB dòng BW0 Fuji Electric mới nhất 2019
Presentation smart city presentation by cs electric (4)
Zaman associates product presentation
Catalogue ACB BT3 - Air Circuit Breaker BT3 Fuji - Beeteco.com
Bh bv din series dienhathe.org
Ad

4-Distribution Components

  • 2. RDW2 Series Intelligent Universal Circuit Breaker Confirms to: IEC60947-2 Frame size: 1600, 2500, 4000, 6300A Rated current: 200A~6300A Rated operating voltage: AC 400V, AC 690V Number of pole: 3P, 4P Breaking capacity: 25kA~125kA Installation mode: Fixed type, Drawer type RDW1 Series Intelligent Universal Circuit Breaker Confirms to: IEC60947-2 Frame size: 630, 1000, 2000, 3200, 4000, 6300A Rated current: 100A~6300A Rated operating voltage: AC 400V Number of pole: 3P, 4P Breaking capacity: 42kA~120kA Installation mode: Fixed type, Drawer type RDW17 Series Intelligent Universal Circuit Breaker Confirms to: IEC60947-2 Frame size: 1600, 1605, 2500, 2505, 3200, 3205A Rated current: 630A~5000A Rated operating voltage: AC 380V, AC 660V Number of pole: 3P, 4P Breaking capacity: 50kA~80kA Installation mode: Fixed type, Drawer type DW15 Series Intelligent Universal Circuit Breaker Confirms to: IEC60947-2 Frame size: 630, 1600, 2500, 4000, 6300A Rated current: 200A~6300A Rated operating voltage: AC 380V Number of pole: 3P Breaking capacity: 20kA~80kA Installation mode: Fixed type, Drawer type (only for 630 type) DW16 Series Intelligent Universal Circuit Breaker Confirms to: IEC60947-2 Frame size: 630, 2000, 4000A Rated current: 100A~4000A Rated operating voltage: AC 400V Number of pole: 3P Breaking capacity: 20kA~80kA RDM1 Series Moulded Case Circuit Breaker (MCCB) Confirms to: IEC60947-2 Frame size: 63, 100, 250, 400, 630, 800, 1250A Rated current: 10A~1250A Rated operating voltage: AC 400V, AC 690V Number of pole: 2P (only for 100, 250 type), 3P, 4P Breaking capacity: 25kA~100kA RDM1E Series Moulded Case Circuit Breaker (MCCB) Confirms to: IEC60947-2 Frame size: 63, 100, 250, 400, 630, 800, 1250A Rated current: 10A~1250A Rated operating voltage: AC 400V, AC 690V Number of pole: 3P, 4P Breaking capacity: 25kA~100kA RDM11 Series Moulded Case Circuit Breaker (MCCB) Confirms to: IEC60947-2 Frame size: 100, 160, 250, 400, 630A Rated current: 16A~630A Rated operating voltage: AC 690V Number of pole: 3P, 4P Breaking capacity: 25kA~50kA www.peopleelectric.com 016
  • 3. RDM6 Series Moulded Case Circuit Breaker (MCCB) Confirms to: IEC60947-2 Frame size: 125, 160, 250, 400, 630, 800, 1250, 1600A Rated current: 12.5A~1600A Rated operating voltage: AC 400V Number of pole: 3P, 4P Breaking capacity: 25kA~65kA DZ20 Series Moulded Case Circuit Breaker (MCCB) Confirms to: IEC60947-2 Frame size: 100, 225, 400, 630, 1250, 2000A Rated current: 16A~2000A Rated operating voltage: AC 380V Number of pole: 3P, 4P Breaking capacity: 18kA~100kA RDM108 Series Moulded Case Circuit Breaker (MCCB) Confirms to: IEC60947-2 Frame size: 20, 32, 63A Rated current: 0.16A~63A Rated operating voltage: AC 660V Number of pole: 3P Breaking capacity: 1.5kA~22kA DZ15 Series Moulded Case Circuit Breaker (MCCB) Confirms to: IEC60947-2 Frame size: 40, 100A Rated current: 6A~100A Rated operating voltage: AC 220V, AC 380V Number of pole: 1P, 2P, 3P, 4P Breaking capacity: 3kA~5kA RDM10 Series Moulded Case Circuit Breaker (MCCB) Confirms to: IEC60947-2 Frame size: 100, 160, 400, 630A Rated current: 16A~630A Rated operating voltage: AC 400V Number of pole: 3P Breaking capacity: 7.5kA~15kA RDM1L Series Residual Operated Circuit Breaker Confirms to: IEC60947-2 Frame size: 100, 225, 400, 800A Rated current: 10A~800A Rated operating voltage: AC 400V Number of pole: 2P (only for 100M, 225L, 225M type), 3P, 4P Breaking capacity: 35kA~100kA Residual operated current: 30/100/300/500/1000mA RDL20 Series Residual Operated Circuit Breaker Confirms to: IEC60947-2 Frame size: 160, 250, 400, 630A Rated current: 50A~630A Rated operating voltage: AC 380V Number of pole: 3P +N Breaking capacity: 12kA~30kA Residual operated current: 100/200/300/500mA RDM30LE Series Intelligent Leakage Circuit Breaker Confirms to: IEC60947-2 Frame size: 100, 250, 400, 630A Rated current: 63A~630A Rated operating voltage: AC 380V Number of pole: 3P +N Breaking capacity: 6kA~36kA Residual operated current: 100/300/500/1000mA 017 www.peopleelectric.com Distribution Components
  • 4. DZL25 Series Leakage Circuit Breaker Confirms to: IEC60947-2 Frame size: 100, 250A Rated current: 40A~250A Rated operating voltage: AC 380V Number of pole: 4P Breaking capacity: 6kA, 10kA Residual operated current: 30/50/100/200/300/500mA DZ15LE Series Leakage Circuit Breaker Confirms to: IEC60947-2 Frame size: 40, 100A Rated current: 6A~100A Rated operating voltage: AC 220V, AC 380V Number of pole: 2P, 3P, 4P Breaking capacity: 3kA, 5kA Residual operated current: 30/50/75/100mA RDM10L Series Leakage Circuit Breaker Confirms to: IEC60947-2 Frame size: 100, 250A Rated current: 40A~250A Rated operating voltage: AC 380V Number of pole: 4P Breaking capacity: 6kA, 10kA Residual operated current: 75/100/150/200/300mA RDL18 Series Leakage Circuit Breaker Confirms to: IEC60947-2 Frame size: 20, 32A Rated current: 10A~32A Rated operating voltage: AC 220V Number of pole: 2P Breaking capacity: 500A Residual operated current: 30mA RDQH Series Dual Power Supply Automatic Transfer Switch Confirms to: GB/T14048.11 Frame size: 63, 100, 225, 400, 630, 800, 1250, 1600A Rated current: 10A~1600A Rated operating voltage: AC 400V Number of pole: 3P, 4P Breaking capacity: 5kA~35kA ATS grade: CB class RDQ1 Series Dual Power Supply Automatic Transfer Switch Confirms to: GB/T14048.11 Frame size: 63A Rated current: 6A~63A Rated operating voltage: AC 220V, AC 400V Number of pole: 2P, 3P, 4P Breaking capacity: 5kA ATS grade: CB class RDWQ2 Series Dual Power Supply Automatic Transfer Switch Confirms to: GB/T14048.11 Frame size: 1000, 2000, 3200, 4000, 6300A Rated current: 200A~6300A Rated operating voltage: AC 400V Number of pole: 3P, 4P Breaking capacity: 10kA~100kA ATS grade: CB class RDQ6 Series Dual Power Supply Automatic Transfer Switch Confirms to: GB/T14048.11 Rated current: 63A~3150A Rated operating voltage: AC 400V Number of pole: 2P, 3P, 4P Breaking capacity: 5kA~80kA ATS grade: PC class www.peopleelectric.com 018
  • 5. RDH5D Series Dual Power Supply Automatic Transfer Switch Confirms to: GB/T14048.11 Rated current: 32A~3200A Rated operating voltage: AC 400V Number of pole: 3P, 4P Breaking capacity: 5kA~80kA ATS grade: PC class HD, HS Series Open Type Knife Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 200, 400, 600, 1000, 1500, 2000, 3000A Rated current: 100~3000A Rated operating voltage: AC 400V Rated impact withstand voltage: 8kV Rated short-time withstand current: 6kA~50kA Number of pole: 1P, 2P, 3P, 4P HS11FH Series Protective Open Type Knife Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 100, 200, 400A Rated current: 100~400A Rated operating voltage: AC 400V Rated impact withstand voltage: 8kV Rated short-time withstand current: 6kA~20kA Number of pole: 3P, 4P HD11F Series Open Type Knife Switch Mistake-proof Confirms to: GB14048.3, IEC60947-3 Frame size: 100, 200, 400A, 600, 1000, 1500A Rated current: 100~1500A Rated operating voltage: AC 400V Rated impact withstand voltage: 8kV Rated short-time withstand current: 6kA~40kA Number of pole: 3P, 4P HD11FH Series Protective Open Type Knife Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 100, 200, 400A Rated current: 100~400A Rated operating voltage: AC 400V Rated impact withstand voltage: 8kV Rated short-time withstand current: 6kA~20kA Number of pole: 3P, 4P HR3 Series Fuse Knife Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 100, 200, 400, 600, 1000A Rated current: 100~1000A Rated operating voltage: AC 400V Rated impact withstand voltage: 8kV Rated limit short-circuit current: 50kA Number of pole: 3P RDHG1 Series Fuse Isolation Switch Confirms to: GB14048.3, IEC60947-3 Rated current: 32~63A Rated operating voltage: AC 400V Rated impact withstand voltage: 8kV Rated limit short-circuit current: 50kA Electrical life: 200~600 times Number of pole: 3P HR18 Series Fuse Knife Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 160, 250, 400, 630A Rated current: 160~630A Rated operating voltage: AC 400V, AC 660V Rated impact withstand voltage: 8kV Rated limit short-circuit current: 50kA Electrical life: 200~600 times Number of pole: 3P 019 www.peopleelectric.com Distribution Components
  • 6. RDHG2B Series Strip Type Fuse Switch Disconnector Confirms to: GB14048.3, IEC60947-3 Frame size: 160, 250, 400, 630A Rated current: 160~630A Rated operating voltage: AC 400V, AC 690V Rated impact withstand voltage: 8kV Rated limit short-circuit current: 50kA Electrical life: 200~600 times Number of pole: 3P HR5 Series Fuse Isolation Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 160, 250, 400, 630A Rated operating voltage: AC 380V, AC 660V Rated impact withstand voltage: 8kV Rated limit short-circuit current: 50~100kA Number of pole: 3P HR6 Series Fuse Isolation Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 160, 250, 400, 630A Rated operating voltage: AC 380V, AC 660V Rated impact withstand voltage: 8kV Rated limit short-circuit current: 50~100kA Number of pole: 3P HR17B Series Fuse Isolation Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 40, 60, 160, 250, 400, 630A Rated operating current: 40~630A Rated operating voltage: AC 400V Rated impact withstand voltage: 8kV Rated limit short-circuit current: 50kA Electrical life: 200~600 times Number of pole: 2P, 3P, 4P RDH5 Series Isolation Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 63, 100, 125, 160, 200, 400, 630, 1000, 1250, 1600, 2000, 2500, 3200A Rated operating current: 63~3200A Rated operating voltage: AC 400V Rated impact withstand voltage: 8kV Operation mode: operation inside of cabinet, operation outside of cabinet Number of pole: 3P, 4P RDH5R Series Isolation Switch Fuse Group Confirms to: GB14048.3, IEC60947-3 Frame size: 160, 400, 630A Rated operating current: 160~630A Rated operating voltage: AC 380V Rated impact withstand voltage: 8kV Rated limit short-circuit current: 50kA Number of pole: 2P, 3P, 4P HH15 Series Isolation Switch Fuse Group Confirms to: GB14048.3, IEC60947-3 Rated operating current: (QSA) 63~800A (QA) 125~1000A (QP) 250~3150A Rated operating voltage: AC 380V, AC 660V, Rated limit short-circuit current: 50kA Operation mode: operation outside of cabinet Number of pole: 3P JDW2 Series Low Voltage Outdoor Isolation Switch Confirms to: GB14048.3, IEC60947-3 Rated operating current: 200~800A Rated operating voltage: AC 500V www.peopleelectric.com 020
  • 7. HH3 Series Load Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 60, 100, 150, 200, 300, 400, 600A Rated current: 60~600A Rated voltage: AC 380V Rated limit short-circuit current: 50kA Number of pole: 3P HH4 Series Load Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 15, 30, 60, 100A Rated current: 15~100A Rated voltage: AC 380V Rated limit short-circuit current: 50kA Number of pole: 3P HK2 Series Load Switch Confirms to: GB14048.3, IEC60947-3 Frame size: 16, 32, 63, 75A Rated current: 16~75A Rated voltage: AC 220V, AC 380V Rated limit short-circuit current: 50kA Number of pole: 2P, 3P RDT16 Series Powder Filled Cartridge Knife Type Contact Fuse Confirms to: GB/T13539.2, IEC60269-2 Rated current: 10~1250A Rated voltage: Up to AC 690V Rated breaking capacity: 120kA Scope of breaking and usage category: gG type and aM type It is mainly used for electric circuit’s over-load and short-circuit protection RDF16 Series Powder Filled Cartridge Knife Type Contact Fuse Confirms to: GB/T13539.2, IEC60269-2 Rated current: 16~630A Rated voltage: Up to AC 690V Rated breaking capacity: 50kA Scope of breaking and usage category: gG type It is mainly used for electric circuit’s over-load and short-circuit protection RL1 Series Screw Type Fuse Confirms to: GB/T13539.3, IEC60269-3 Rated current: 2~200A Rated voltage: AC 380V Rated breaking capacity: 50kA Scope of breaking and usage category: gG type It is mainly used for electric circuit’s over-load and short-circuit protection RT18, HG30 Series Powder Filled Cartridge Cylindrical Cape Fuse Confirms to: GB/T13539.2, IEC60269-2 Rated current: 2~125A Rated voltage: AC 380V Rated breaking capacity: 50kA Scope of breaking and usage category: gG type and aM type It is mainly used for electric circuit’s over-load and short-circuit protection RT19 Series Powder Filled Cartridge Cylindrical Cape Fuse Confirms to: GB/T13539.2, IEC60269-2 Rated current: 2~100A Rated voltage: AC 380V Rated breaking capacity: 50kA Scope of breaking and usage category: gG type and aM type It is mainly used for electric circuit’s over-load and short-circuit protection 021 www.peopleelectric.com Distribution Components
  • 8. RT14 Series Powder Filled Cartridge Cylindrical Cape Fuse Confirms to: GB/T13539.2, IEC60269-2 Rated current: 2~63A Rated voltage: AC 380V Rated breaking capacity: 50kA Scope of breaking and usage category: gG type It is mainly used for electric circuit’s over-load and short-circuit protection RT0 Series Powder Filled Cartridge Knife Type Contact Fuse Confirms to: GB/T13539.2, IEC60269-2 Rated current: 10~1000A Rated voltage: AC 380V Rated breaking capacity: 50kA Scope of breaking and usage category: gG type It is mainly used for electric circuit’s over-load and short-circuit protection RS0, RS3 Series Fast Fuse Confirms to: GB/T13539.4, IEC60269-4 Rated current: (RS 0) 10A~1250A (RS 0) 10A~1000A Rated voltage: AC 380V Rated breaking capacity: 50kA Scope of breaking and usage category: aR type It is mainly used for the protection of semiconductor crystal tube and its complete equipment NGT Series Fast Fuse Confirms to: GB/T13539.4, IEC60269-4 Rated current: 25~630A Rated voltage: AC 380V, 660V, 800V, 1000V Rated breaking capacity: 100kA Scope of breaking and usage category: aR type It is mainly used for the protection of semiconductor crystal tube and its complete equipment BSMJ (Y), BZMJ (Y) Series Auto- Healing Low Voltage Shunt Capacitor Confirms to: GB/T12847, IEC831-1 Rated operating voltage: AC 250V, AC 400V, AC 450V AC 525V, AC 690V, AC 750V Rated capacity: 1-50kvar It can be used with CJ 19, combination switch RD-ZM Series Intelligent Low Voltage Capacitor Confirms to: GB/T29312 Rated operating voltage: AC 380V/ 220V Rated capacity: total compensation of 5~40kvar; separated compensation of 5~20kvar It can compensation in situ by one machine, and also can networking to intelligently automatic operation by multi-machines, and no need to add reactive compensation controller to control. JKW5C Series Low Voltage Reactive Compensation Controller Confirms to: JB/T 9663 Rated operating voltage: AC 220V/ 380V Rated current: AC 0~5A Capacity of contacts: AC 220V 5A Controlled circuit No.: 1~12 circuits Protection grade: IP40 JKW6C Series Low Voltage Reactive Compensation Controller Confirms to: JB/T 9663 Rated operating voltage: AC 220V/ 380V Rated current: AC 0~5A Capacity of contacts: AC 220V 5A Controlled circuit No.: 1~12 circuits Protection grade: IP40 www.peopleelectric.com 022
  • 9. JKL6C, JKL6B Series Low Voltage Reactive Compensation Controller Confirms to: JB/T 9663 Rated operating voltage: AC 220V/ 380V Rated current: AC 0~5A Capacity of contacts: AC 220V 5A Controlled circuit No.: 1~12 circuits Protection grade: IP 40 JKG2B, JKW5B Series Low Voltage Reactive Compensation Controller Confirms to: JB/T 9663 Rated operating voltage: AC 220V/ 380V Rated current: AC 0~5A Capacity of contacts: AC 220V 5A Controlled circuit No.: 1~12 circuits Protection grade: IP 40 JKWR Series Low Voltage Reactive Compensation Controller Confirms to: JB/T 9663 Rated operating voltage: AC 220V Rated current: AC 0~5A Capacity of contacts: AC 220V 7A Controlled circuit No.: 1~13 circuits Protection grade: IP 40 DB Series Distribution Box JXF Series Outdoor Distribution Box Enclosure Rated voltage: 220/380V Rated current: 125A Installation: Surface mounted Protection grade: Ip65 Height: 250; 300; 400; 500; 600; 800; 1000; 1200mm, etc. Width: 200; 250; 300; 400; 500; 600; 1000mm, etc. Depth: 150; 200; 250; 300mm, etc. Modules: 4, 6, 8, 12, 18, 24, 34 ways Installation: Surface mounting, Flush mounting Material: Plastic, Metal Protection grade: IP40 023 www.peopleelectric.com Distribution Components