SlideShare a Scribd company logo
Andrew L6PNF-RPC
Andrew L6PNF-RPC
B-MD- CONNECTOR, 1 1/4IN TYPE…
_______________________________________
How to Buy
Call: 1-877-878-9134 for this product Email: sales@launch3.net Click to send an RFQ:
http://www.launch3telecom.com/andrew/l6pnfrpc.html
Part number: L6PNF-RPC Datasheets: https://www.launch3telecom.com/shared_
media/datasheet/e92a657d499d5bd7b38e
bd931f7c7d57-L6PNF-RPC.pdf
Manufacturer: Andrew Weight: N/A
Title: B-MD- CONNECTOR, 1
1/4IN TYPE…
Category: N/A
Description: B-MD- CONNECTOR, 1
1/4IN TYPE N FEMALE
OnePiece(TM) for 1-1/4
in LDF6-50 cable
Genre: Wireless
Heci: N/A
Part Page URL:
About Us
Launch 3 Telecom is your one stop shop for all your Telecom and Data/Networking
Hardware needs and genuine Andrew replacement parts. We have loyally served our
customers since 2003. Our product expertise, quality customer service, competitive pricing
-on items like this Andrew L6PNF-RPC -- are a few of the reasons why more telecom
professionals buy from Launch 3 Telecom every day.
_______________________________________
Payment and Processing
We accept Visa, Mastercard, American Express and Paypal payments for this Andrew
L6PNF-RPC. We can also accept Purchase Orders for Net Terms upon approval. Launch 3
Telecom does have a Government Cage Code so if this is for a Government purchase please
tells us! You may also call us at 877-878-9134 or email us at sales@launch3.net for our
credit card form. Please call us today to purchase this Andrew L6PNF-RPC item while
inventory and sale last.
Same Day Shipping, Order Confirmation and Order
Tracking
Once your order is placed for the Andrew L6PNF-RPC, you may select from several shipping
methods, including UPS, Federal Express, DHL, USPS, 3 day, 2 day, overnight and
international methods. Orders received and approved before 3PM EST will generally ship
the same business day. You will receive an order confirmation email for your Andrew
L6PNF-RPC along with the tracking number as soon as it is available. The tracking number
will allow you to track your shipment in real time. We pack the Andrew L6PNF-RPC in anti-
static bubble wrap to ensure safe delivery. We will combine multiple items in one shipment
whenever possible to save on shipping time and costs. Because we have several
distribution points and vendor locations, sometimes orders will be divided into multiple
shipments, but never at extra cost to you.
_______________________________________
Warranty
Every item you purchase from us includes a warranty and our hassle-free return policy. We
stand by our product and your satisfaction is our goal. If you ever have questions or
concerns about your Andrew L6PNF-RPC order, simply contact our Customer Service
Department at 877-878-9134, Monday - Friday, 9 AM - 5 PM EST. Friendly customer service
reps are available to assist you with your order.
Services from Launch 3 Telecom
Launch 3 Telecom can also repair the Andrew
L6PNF-RPC, provides maintenance contracts,
De-installation, Telecom Consignment and
Recycling. Please contact Launch 3 Telecom to
learn more about these services! Launch 3
Telecom specializes in installation of all
telecom related systems. Our team is equipped
to handle all telecom equipment including
cellular, Fixed Wireless, WiMAX, Central Office,
and more. No project is too small or too big,
and each is handled by a dedicated telecom
professional.
De-Installation - Our Network Installation
Experts will properly de-install your equipment,
package it, and ship it to our warehouse for
storage.
Testing - Our team of technicians will inspect
each piece of equipment thoroughly. If a piece
of equipment needs repair, we’ll provide the
resources and technology to guarantee each
piece is ready to be sold.
Asset Recovery - We can store your equipment
in one of our expansive warehouses located
around the country until your equipment is
sold so you can save on storage costs and avoid
cluttering your equipment floor.
Repair Services - Launch 3 Telecom is your one-
stop solution to your entire Telecom
Equipment & System repair. Our team of
dedicated professionals will get your system
back up and running quickly and efficiently. We
repair cell sites, central office switching,
combiners, data networking, transmission,
power supplies, microwave, radios, IP Cameras,
Sonet /SHD, power, power amps, CDMA, GSM,
TDMA, and PBX Keyphone.
Third Party Logistics - If you are currently
operating a direct route or if you are interested
in setting one up, Launch 3 Telecom would like
to discuss the opportunity of sending you
traffic. Contact us today to speak to a Call
Termination Specialist for more details at
voip@launch3telecom.com
Product Specifications L6PNF-RPC L6PNF- Type N Female OnePiece™ for 11/4 in LDF650 cable OBSOLETE Replaced By L6TNF-
PS Type N Female Positive Stop™ for 11/4 in LDF650 cable General Specifications Interface N Female Body Style Straight Brand HELIAX®
Mounting Angle Straight | OnePiece™ Electrical Specifications Connector Impedance 50 ohm Operating Frequency Band 0 –
3300 MHz Cable Impedance 50 ohm 3rd Order IMD, typical -
120 dBm @ 910 MHz 3rd Order IMD Test Method Two +43 dBm carriers RF Operating Voltage, maximum (vrms) 707.00 V dc Test Voltage
2000 V Outer Contact Resistance, maximum 0.30 mOhm Inner Contact Resistance, maximum 2.00 mOhm Insulation Resistance, minimu
m 5000 MOhm Average Power 0.6 kW @ 900 MHz Peak Power, maximum 10.00 kW Insertion Loss, typical 0.05 dB Shielding Effectiven
ess 130 dB ©2015 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of
CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised:
July 26, 2013 page 1 of 3 June 26, 2015 _x000C_Product Specifications L6PNF-RPC L6PNF- Outline Drawing Mechanical Specifications
Outer Contact Attachment Method Ball clamp Inner Contact Attachment Method Captivated Outer Contact Plating Trimetal Inner Cont
act Plating Gold Attachment Durability 25 cycles Interface Durability 500 cycles Interface Durability Method IEC 61169-
16:9.5 Connector Retention Tensile Force 1779 N Connector Retention Torque 10.85 Nm | Insertion Force 66.72 N
15.00 lbf Insertion Force Method MILC39012C3.12, 4.6.9 Pressurizable No | 400 lbf | 96.00 in lb Dimensions Nominal Size 1-
1/4 in Diameter 51.99 mm Length 78.99 mm Weight 472.00 g | | | 2.05 in 3.11 in 1.04 lb Environmental Specifications
Operating Temperature 55 °C to +85 °C (67 °F to +185 °F) Storage Temperature 55 °C to +85 °C (-
67 °F to +185 °F) Immersion Depth 1 m ©2015 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered
trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most
current information. Revised: July 26, 2013 page 2 of 3 June 26, 2015 _x000C_Product Specifications L6PNF-RPC
L6PNFImmersion Test Mating Unmated Immersion Test Method IEC 60529:2001, IP68 Water Jetting Test Mating Unmated Water Jetting
Test Method IEC 60529:2001, IP66 Moisture Resistance Test Method MILSTD202F, Method 106F Mechanical Shock Test Method MILSTD-
202F, Method 213B, Test Condition C Thermal Shock Test Method MILSTD202F, Method 107G, Test Condition A1, Low Temperature -
55 °C Vibration Test Method MILSTD202F, Method 204D, Test Condition B Corrosion Test Method MILSTD-
1344A, Method 1001.1, Test Condition A Standard Conditions Attenuation, Ambient Temperature 20 °C |
68 °F Average Power, Ambient Temperature 40 °C | 104 °F Return Loss/VSWR Frequency Band 40–1000 MHz 1010–2200 MHz 2210–
3300 MHz VSWR 1.02 1.03 1.04 Return Loss (dB) 39.00 38.00 34.00 Regulatory Compliance/Certifications Agency RoHS 2011/65/EU
China RoHS SJ/T 113642006 Classification Compliant by Exemption Above Maximum Concentration Value (MCV) * Footnotes
Immersion Depth Immersion at specified depth for 24 hours Insertion Loss, typical 0.05v¯freq (GHz) (not applicable for elliptical waveguide
) ©2015 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All
specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 26, 2013 page
3 of 3 June 26, 2015 _x000C_

More Related Content

PPTX
Andrew L5PNF-RPC
PPTX
Andrew L6PDM-RPC
PPTX
Andrew L7PNF-RPC
PPTX
Andrew L7PDF-RPC
PPTX
Andrew L6PDF-RPC
PPTX
Andrew L6TDF-PS
PPTX
Andrew L4TNF-PSA
PPTX
Andrew L4TDF-PSA
Andrew L5PNF-RPC
Andrew L6PDM-RPC
Andrew L7PNF-RPC
Andrew L7PDF-RPC
Andrew L6PDF-RPC
Andrew L6TDF-PS
Andrew L4TNF-PSA
Andrew L4TDF-PSA

What's hot (20)

PPTX
Andrew L5TDF-PS
PPTX
Andrew L4TDF-PS
PPTX
Andrew L7PNM-RPC
PPTX
Andrew L7TDF-PS
PPTX
Andrew L4TNM-PSA
PPTX
Andrew AL7DF-PSA
PPTX
Andrew L5TNF-PS
PPTX
Andrew L7PDM-RPC
PPTX
Andrew L4PNF-RC
PPTX
Andrew AL6DF-PSA
PPTX
Andrew L4TDM-PSA
PPTX
Commscope-Andrew AL5NF-PSA
PPTX
Andrew L5PDM-RPC
PPTX
Andrew F4PNF-C
PPTX
Andrew L5PDF-RPC
PPTX
123eWireless AL5DF-PSA
PPTX
Commscope-Andrew L44R
PPTX
Commscope-Andrew 540EZDMV2
PPTX
Commscope-Andrew AL5DF-PS
PPTX
Andrew L5PNM-RPC
Andrew L5TDF-PS
Andrew L4TDF-PS
Andrew L7PNM-RPC
Andrew L7TDF-PS
Andrew L4TNM-PSA
Andrew AL7DF-PSA
Andrew L5TNF-PS
Andrew L7PDM-RPC
Andrew L4PNF-RC
Andrew AL6DF-PSA
Andrew L4TDM-PSA
Commscope-Andrew AL5NF-PSA
Andrew L5PDM-RPC
Andrew F4PNF-C
Andrew L5PDF-RPC
123eWireless AL5DF-PSA
Commscope-Andrew L44R
Commscope-Andrew 540EZDMV2
Commscope-Andrew AL5DF-PS
Andrew L5PNM-RPC
Ad

Similar to Andrew L6PNF-RPC (15)

PPTX
Andrew L7TNF-PS
PPTX
Andrew A7PDF-RPC
PPTX
Andrew A7TDF-PS
PPTX
Andrew L4PNF
PPTX
Andrew AL7NM-PS
PPTX
Andrew AL7NF-PS
PPTX
Andrew AL7NF-PSA
PPTX
Andrew L7TDM-PS
PPTX
Andrew F4PNMV2-HC
PPTX
Andrew L12PDF
PPTX
Andrew L4DR-PS
PPTX
Andrew L4PDM-RC
PPTX
Andrew L5TDM-PS
PPTX
Andrew L4PDR-C
PPTX
Andrew CA-TNMDF
Andrew L7TNF-PS
Andrew A7PDF-RPC
Andrew A7TDF-PS
Andrew L4PNF
Andrew AL7NM-PS
Andrew AL7NF-PS
Andrew AL7NF-PSA
Andrew L7TDM-PS
Andrew F4PNMV2-HC
Andrew L12PDF
Andrew L4DR-PS
Andrew L4PDM-RC
Andrew L5TDM-PS
Andrew L4PDR-C
Andrew CA-TNMDF
Ad

Andrew L6PNF-RPC

  • 2. Andrew L6PNF-RPC B-MD- CONNECTOR, 1 1/4IN TYPE… _______________________________________ How to Buy Call: 1-877-878-9134 for this product Email: sales@launch3.net Click to send an RFQ: http://www.launch3telecom.com/andrew/l6pnfrpc.html
  • 3. Part number: L6PNF-RPC Datasheets: https://www.launch3telecom.com/shared_ media/datasheet/e92a657d499d5bd7b38e bd931f7c7d57-L6PNF-RPC.pdf Manufacturer: Andrew Weight: N/A Title: B-MD- CONNECTOR, 1 1/4IN TYPE… Category: N/A Description: B-MD- CONNECTOR, 1 1/4IN TYPE N FEMALE OnePiece(TM) for 1-1/4 in LDF6-50 cable Genre: Wireless Heci: N/A Part Page URL:
  • 4. About Us Launch 3 Telecom is your one stop shop for all your Telecom and Data/Networking Hardware needs and genuine Andrew replacement parts. We have loyally served our customers since 2003. Our product expertise, quality customer service, competitive pricing -on items like this Andrew L6PNF-RPC -- are a few of the reasons why more telecom professionals buy from Launch 3 Telecom every day. _______________________________________ Payment and Processing We accept Visa, Mastercard, American Express and Paypal payments for this Andrew L6PNF-RPC. We can also accept Purchase Orders for Net Terms upon approval. Launch 3 Telecom does have a Government Cage Code so if this is for a Government purchase please tells us! You may also call us at 877-878-9134 or email us at sales@launch3.net for our credit card form. Please call us today to purchase this Andrew L6PNF-RPC item while inventory and sale last.
  • 5. Same Day Shipping, Order Confirmation and Order Tracking Once your order is placed for the Andrew L6PNF-RPC, you may select from several shipping methods, including UPS, Federal Express, DHL, USPS, 3 day, 2 day, overnight and international methods. Orders received and approved before 3PM EST will generally ship the same business day. You will receive an order confirmation email for your Andrew L6PNF-RPC along with the tracking number as soon as it is available. The tracking number will allow you to track your shipment in real time. We pack the Andrew L6PNF-RPC in anti- static bubble wrap to ensure safe delivery. We will combine multiple items in one shipment whenever possible to save on shipping time and costs. Because we have several distribution points and vendor locations, sometimes orders will be divided into multiple shipments, but never at extra cost to you. _______________________________________ Warranty Every item you purchase from us includes a warranty and our hassle-free return policy. We stand by our product and your satisfaction is our goal. If you ever have questions or concerns about your Andrew L6PNF-RPC order, simply contact our Customer Service Department at 877-878-9134, Monday - Friday, 9 AM - 5 PM EST. Friendly customer service reps are available to assist you with your order.
  • 6. Services from Launch 3 Telecom Launch 3 Telecom can also repair the Andrew L6PNF-RPC, provides maintenance contracts, De-installation, Telecom Consignment and Recycling. Please contact Launch 3 Telecom to learn more about these services! Launch 3 Telecom specializes in installation of all telecom related systems. Our team is equipped to handle all telecom equipment including cellular, Fixed Wireless, WiMAX, Central Office, and more. No project is too small or too big, and each is handled by a dedicated telecom professional. De-Installation - Our Network Installation Experts will properly de-install your equipment, package it, and ship it to our warehouse for storage. Testing - Our team of technicians will inspect each piece of equipment thoroughly. If a piece of equipment needs repair, we’ll provide the resources and technology to guarantee each piece is ready to be sold. Asset Recovery - We can store your equipment in one of our expansive warehouses located around the country until your equipment is sold so you can save on storage costs and avoid cluttering your equipment floor. Repair Services - Launch 3 Telecom is your one- stop solution to your entire Telecom Equipment & System repair. Our team of dedicated professionals will get your system back up and running quickly and efficiently. We repair cell sites, central office switching, combiners, data networking, transmission, power supplies, microwave, radios, IP Cameras, Sonet /SHD, power, power amps, CDMA, GSM, TDMA, and PBX Keyphone. Third Party Logistics - If you are currently operating a direct route or if you are interested in setting one up, Launch 3 Telecom would like to discuss the opportunity of sending you traffic. Contact us today to speak to a Call Termination Specialist for more details at voip@launch3telecom.com
  • 7. Product Specifications L6PNF-RPC L6PNF- Type N Female OnePiece™ for 11/4 in LDF650 cable OBSOLETE Replaced By L6TNF- PS Type N Female Positive Stop™ for 11/4 in LDF650 cable General Specifications Interface N Female Body Style Straight Brand HELIAX® Mounting Angle Straight | OnePiece™ Electrical Specifications Connector Impedance 50 ohm Operating Frequency Band 0 – 3300 MHz Cable Impedance 50 ohm 3rd Order IMD, typical - 120 dBm @ 910 MHz 3rd Order IMD Test Method Two +43 dBm carriers RF Operating Voltage, maximum (vrms) 707.00 V dc Test Voltage 2000 V Outer Contact Resistance, maximum 0.30 mOhm Inner Contact Resistance, maximum 2.00 mOhm Insulation Resistance, minimu m 5000 MOhm Average Power 0.6 kW @ 900 MHz Peak Power, maximum 10.00 kW Insertion Loss, typical 0.05 dB Shielding Effectiven ess 130 dB ©2015 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 26, 2013 page 1 of 3 June 26, 2015 _x000C_Product Specifications L6PNF-RPC L6PNF- Outline Drawing Mechanical Specifications Outer Contact Attachment Method Ball clamp Inner Contact Attachment Method Captivated Outer Contact Plating Trimetal Inner Cont act Plating Gold Attachment Durability 25 cycles Interface Durability 500 cycles Interface Durability Method IEC 61169- 16:9.5 Connector Retention Tensile Force 1779 N Connector Retention Torque 10.85 Nm | Insertion Force 66.72 N 15.00 lbf Insertion Force Method MILC39012C3.12, 4.6.9 Pressurizable No | 400 lbf | 96.00 in lb Dimensions Nominal Size 1- 1/4 in Diameter 51.99 mm Length 78.99 mm Weight 472.00 g | | | 2.05 in 3.11 in 1.04 lb Environmental Specifications Operating Temperature 55 °C to +85 °C (67 °F to +185 °F) Storage Temperature 55 °C to +85 °C (- 67 °F to +185 °F) Immersion Depth 1 m ©2015 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 26, 2013 page 2 of 3 June 26, 2015 _x000C_Product Specifications L6PNF-RPC L6PNFImmersion Test Mating Unmated Immersion Test Method IEC 60529:2001, IP68 Water Jetting Test Mating Unmated Water Jetting Test Method IEC 60529:2001, IP66 Moisture Resistance Test Method MILSTD202F, Method 106F Mechanical Shock Test Method MILSTD- 202F, Method 213B, Test Condition C Thermal Shock Test Method MILSTD202F, Method 107G, Test Condition A1, Low Temperature - 55 °C Vibration Test Method MILSTD202F, Method 204D, Test Condition B Corrosion Test Method MILSTD- 1344A, Method 1001.1, Test Condition A Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F Return Loss/VSWR Frequency Band 40–1000 MHz 1010–2200 MHz 2210– 3300 MHz VSWR 1.02 1.03 1.04 Return Loss (dB) 39.00 38.00 34.00 Regulatory Compliance/Certifications Agency RoHS 2011/65/EU China RoHS SJ/T 113642006 Classification Compliant by Exemption Above Maximum Concentration Value (MCV) * Footnotes Immersion Depth Immersion at specified depth for 24 hours Insertion Loss, typical 0.05v¯freq (GHz) (not applicable for elliptical waveguide ) ©2015 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 26, 2013 page 3 of 3 June 26, 2015 _x000C_