SlideShare a Scribd company logo
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
10
CFD INVESTIGATION OF CEILING SHAPE ON AIRFLOW
DISTRIBUTION FOR A GENERIC 2-D ROOM MODEL WITH AND
WITHOUT PASSIVE CONTROL
N.S.Venkatesh Kumar1
, Prof. K. Hema Chandra Reddy2
1
(Principal, Govt. Polytechnic, Pillaripattu, Nagari, (Chittoor Dist.), A.P., India and Research
Scholar, Department of Mechanical Engg, JNTUA, Anantapuram, A.P., India)
2
(Registrar, JNTUA, Anantapuram, A.P., India)
ABSTRACT
Natural ventilation, which provides occupants with good indoor air quality and a high level of
thermal comfort with reduced energy costs, has been drawing utmost importance in sustainable
strategy in building designs. Air flow distribution in a 2-D room with cross ventilation under
different ceiling shape is investigated in this present paper using computational simulations carried
with ANSYS-CFX, commercial CFD software. Investigation of air flow distribution is important to
understand convective flow distribution and to control the flow to achieve its effective distribution
for human comfort condition. The flow inside a building may be characterized by separation,
reattachment, recirculation zone and circulation bubble. Within one room model, airflow patterns are
evaluated with and without the presence of an obstacle. The obstacle creates vortex break down
thereby creating the necessary high and low air speed zones necessary for comfort conditions when
comparison is made for a similar situation without obstacle. The ceiling shape designs investigated in
this present paper are Gable single, Gable-flat, Gutter single and Gutter-flat roof structures with and
without passive control of air. The roof shape effect on air flow distribution is captured and
represented by velocity vectors, streamlines and velocity contours and it is observed that location and
the size of the recirculated air variation is sensitive to changes in the building's roof shape and the
placement of the obstacle.
Key words: Ceiling Shape, Air Flow Distribution, Passive Control and CFD.
INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING
AND TECHNOLOGY (IJMET)
ISSN 0976 – 6340 (Print)
ISSN 0976 – 6359 (Online)
Volume 5, Issue 1, January (2014), pp. 10-25
© IAEME: www.iaeme.com/ijmet.asp
Journal Impact Factor (2013): 5.7731 (Calculated by GISI)
www.jifactor.com
IJMET
© I A E M E
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
11
1. INTRODUCTION
The room geometry plays an important role to achieve natural air flow distribution for human
comfort conditions. Good survey about building design criteria, features and practices are given by
Facr [1]. The flow inside a building may be characterized by separation, reattachment, recirculation
zone and circulation bubble. These features can be investigated using simple geometry, two-
dimensional flow that makes a very popular numerical research subject. Several factors influence
airflow pattern inside a building. These include the configuration, location and structure of air inlets
and outlets, the condition of the incoming air and size and shape of building. A recirculation system
can be used to distribute air inside the building. Different arrangements of air inlets and recirculation
air systems would result in different airflow patterns Dr. Ahmed A. Salman et. al. [2] . Bjeg, et. al.
[3] showed that the aspect ratios of the room determined whether the airflow can be two- or three-
dimensional. Iannone [3] showed that the building form and the details of the air outlet and inlet
systems can remarkably affect the ventilation performance. It is possible to start from a simplified
geometry (rectangular room) and modify its form by changing roof slope. Aynsley [4] concluded that
despite the powerful tools in the form of zonal network flow analysis, CFD software and LES
methods used on large naturally ventilated buildings, there is a need for development of simpler
natural ventilation computation method for its use in the preliminary stage of building design of
building shape or orientation. In this case, unresolved issues in computation of natural ventilation for
thermal comfort were discussed.
This paper discusses the airflow pattern, velocity distribution and one of vortex control
systems that might be used inside a room for passive control of air. There are various systems for
changing velocity vectors and reducing vortex strength. As an air stream approaches a solid fence, it
is either forced up and over the obstacle or around it. In buildings with very high ceilings, it is very
difficult to maintain the air velocity near floor level. So, baffles can be installed across the building
width to reconcentrate the airflow along the floor level and to provide personnel comfort.
2. CFD SIMULATIONS
Computational settings and parameters for the reference case are outlined and accordingly the
results for this case are presented. Later on, these settings and parameters will be systematically
modified for the parametric study.
2.1. Computational domain and grid
The dimensions of the generic isolate 2-D building and computational domain were chosen
from [2]. The geometry of the room consists of: two vertical walls, horizontal floor and flat, sloping
or pitched roofs. The buildings had dimensions W x H = 2.4 x 1m2
and depth of the building is 0.25
m to carry simulations in CFX. The computational grid is made of structured mesh with Hexa grid.
The geometry and mesh is generated using ICEM CFD, meshing software.
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
12
(a) single Gable room model (b) single Gutter room model
(c) single Gutter-Flat room model
(d) single Gable-Flat room model
(e) single Gable room model with verticle obstacle
Figure 1: Structured mesh for different ceiling shape geometries
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
13
2.2. Boundary conditions
A uniform velocity of 1.725m/s is given at inlet vent as inlet boundary condition. Outlet
boundary condition is applied at bottom vent and it is assumed that average static pressure is zero to
get normal outlet velocity at outlet. For the floor, vertical wall and roof, the no-slip wall functions
are chosen with zero roughness height. The computational domain with boundary condition and
velocity profile at inlet is as shown below.
Figure 2: Applied Boundary Conditions
2.3. Solver settings
The 3D steady RANS equations were solved in combination with the k-ϵ model. Advection
scheme adapted for solving momentum governing equations is High resolution and for turbulence
equations first order scheme. The convergence criteria are taken as 10-6
.
3. RESULTS AND DISCUSSION
Computational investigation of air flow distribution inside a single and double-zone building
of different ceiling shape are presented. Four ceiling shapes are computationally modeled. The
ceiling geometry specifications are summarized in Table 1. The parameter considered for the
computational investigation is roof slope or roof arc length and the inflow and outflow conditions
remains same for all the cases. Room ventilation should provide wind in desired direction and no
recirculation or dead air zone in occupied regions. To achieve such layouts in practice, obstacles of
different height degrees are imposed. For single gable room model, airflow patterns are evaluated
with and without the presence of an obstacle. The obstacle was placed either on the floor or hanged
from the roof at the plane of symmetry in the middle of the room model. The details of vortex
control geometrical arrangement are shown in Table 2.
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
14
Table 1: Specifications of the case studies
Case
No.
Roof type Room
width [m]
Maximum
height [m]
Roof slope or 1/4 arc angle
[degrees]
1 Single gable roof
2.4
1.105 5
1.32154 15
1.69282 30
2 Single gutter roof 2.4 Same as above
3 Gable - Flat roof 4.8 Same as above
4 Gutter - Flat roof 4.8 Same as above
Table 2: Arrangements for the placement and height of the vertical obstacle
Arrangement No. Obstacle location Obstacle height [m]
1 No obstacle 0.00
2 One obstacle mounted on the floor in the
plane of symmetry
0.43
3 One obstacle mounted on the floor in the
plane of symmetry
0.86
4 Two obstacles mounted on the floor and
hanged from the roof in the plane of
symmetry
0.43 for each one
5 One obstacle hanged from the roof in the
plane of symmetry
0.86
3. 1. Effect of Different Ceiling slope on Single Gable and Gutter Room Models
Computational results presented in this section are for single gable room and single gutter
room with the change of roof slope or arc angle. The air flow distribution and velocity profiles are
presented in the form of vectors, contours and charts. The plots on the right column show contours.
Flow velocity vectors are given in the plot on the left column. In these figures, streamlines that form
closed loops indicate zones of recirculation air or vortices. The fact that these recirculation zones
have areas with high and low flow velocities is also evident in the velocity vector plots. One of these
dominated local vortices occurs in the corner below the inlet edge when the inflow of air is at an
angle of 90 degrees to the windward vertical wall irrespective of the roof shape. As the roof slope
increases, there is a decrease in the recirculation zone that appeared inside the room as shown in
Figures 3-c and 4-c. Results showed that for a gutter with proper height, the air supply flows between
the two circulation zones with opposite directions and spreads along the floor before it is drawn to
the exhaust side and removed. Figure 5a-c shows the normalized horizontal velocity profiles adjacent
to the roof, on the floor and on the plane of symmetry in the middle of the gable (on the left column)
and gutter (on the right column) room models. The velocity profiles adjacent to the roof (Figure 5-a)
show the sensitivity to the roof shape. Increasing the roof slope angle to 30 degrees shows the same
velocity profile for both shapes. Comparison of floor velocity profiles between gable and gutter roof
shape at different pitch angle is given in Figure 5-b. At roof slope equal 5 and 15 degrees, the
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
15
velocity profiles are almost identical. As the roof angle increased, the reattachment length of the
gable model is smaller than that of the gutter model. Figure 5-c shows that, in the plane of symmetry,
no considerable difference between the different shapes as the pitch angle or roof arc length
increases are observed except at the angle 30 degrees.
(a) Roof slope: 5 degrees
(b) Roof slope: 10 degrees
(c) Roof slope: 15 degrees
Figure 3: influence of roof slope angle on air flow distribution in single Gable room model
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
16
(a) Arc angle: 20 degrees
(b) Arc angle: 60 degrees
(c) Arc angle: 120 degrees
Figure 4: influence of arc roof angle on air flow distribution in single Gutter room model
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
17
(a) comparison of roof velocity profiles
(b) comparison of floor velocity profiles
(c) comparison of velocity profiles at the middle vertical plane of the room, x=1.2h
Figure 5: horizontal velocity profile, U/Uin
3. 2. Effect of roof slope or arc angle on Single Gable-flat and Gutter-flat Room Models
The results represented here in form of velocity vector and contour in Figures 6a-c and 7a-c
shows the airflow patterns for three cases of gable-flat and gutter-flat room models. For all models,
one can observe the development of different vortex circulation zones. The flow is attached to the
roof at small roof angles or arc lengths and detaching from the wall nearer to the exit forming large
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
18
vortex region just below the inlet vent and there is a low velocity circulation region at the floor as it
is observed in Figures 6-a and 7-a. As the roof angle increases, the flow detachment from the top
wall occurred much before exit, it is attached to the floor and there is a recirculation or dead zone
region just below the roof. The three recirculation zones as observed in room are shown in Fig. 6-c
and 7-c. In this type of ceiling shape, most of the action occurred in the gable or the gutter regions,
while the airflow pattern is nearly uniform through the flat region. Further investigation showed that
the velocity vector length increased at the connecting joint between gable or gutter and flat roof
surface. Moreover, subdivision of the flow into near-wall jet and a relatively low-speed circulation
flow is mostly distinct. For both gable and gutter flow models, the within-jet velocity keeps high
values up to the exit from the under gutter roof region and then becomes almost uniform till the exit.
The side-by-side comparison of the velocity profiles at different planes for gable-flat and
gutter-flat room models of three different ceiling shapes are shown in Figure 8a-c. In these figures,
the velocity profiles adjacent to the ceiling, on the floor and at a distance equal 1.2 h from the inlet
vent for these three different arrangements are presented. According to Figure 8-a, the normalized
velocity profiles decrease at constant rate to the exit and there is a slightly increase in profile at the
middle of gable and gutter. As the roof angle or arc length increases, there is a sharp decrease in
velocity ratio until the roof vertex angle of the gable zone and then increase in its value up to
connection of gable and flat roof, and then decrease until towards the exit from the room. Similar
behavior is observed for gutter-flat room model. Figure 8-b shows that at roof slope equal 5 degrees
and 10 degrees, the velocity profiles are almost identical. For both gable-flat and gutter-flat models,
the velocity profiles show no significant effect in the flat ceiling zone. Figure 8-c shows that the
typical shape of velocity profiles along the plane of symmetry is maintained and reflects the size of
the recirculation zones.
(a) Roof slope: 5 degrees
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
19
(b) Roof slope: 10 degrees
(c) Roof slope: 15 degrees
Figure 6: influence of roof slope on air flow distribution in single Gable-Flat room model
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
20
(a) Arc angle: 20 degrees
(b) Arc angle: 60 degrees
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
21
(c) Arc angle: 120 degrees
Figure 7: influence of arc roof angle on air flow distribution in single Gutter-Flat room model
(a) comparison of roof velocity profiles
(b) comparison of floor velocity profiles
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
22
(c) Comparison of velocity profiles at the middle vertical plane of the room, x=1.2h
Figure 8: horizontal velocity profile, U/Uin
3. 3. Effect of Vertical Obstacle (Passive Control)
Moving air has momentum and it will keep on moving in a particular direction until it is
turned by an obstacle as considered in a passive control system. Attention therefore must be given to
the obstacle location and height, to create the needed high and low air speed zones. Five different
arrangements for the placement and height of the vertical obstacle are given in Table 2. Figures 9a-e
presents the velocity vectors inside the single gable room model with roof slope equal 15o
(left side)
and the velocity contours (right side) adjacent to the roof and on the floor of that model. Figure 10a-c
shows velocity profiles, at the middle plane of the room, for five different arrangements. Due to the
deflection of air through the room, the airflow patterns for the last four arrangements were quite
different from the one obtained without obstacle (arrangement one). Figure 9-b and 9-c show that as
the obstacle is getting higher and higher, the airflow pattern and the original big vortex gets split into
two vortices on the right and left of the obstacle. The velocity vectors and velocity profiles show that
the zone at the left side of the vertical obstacle has different rotational strength than that of the zone
at the right side. The flow patterns for the fifth arrangement are similar to the arrangement of the
other four. However, the centers of the rotary zones are different. When the obstacle hanged from the
roof, as shown in Figure 9-d and 9-e, the big circulation zone near the roof is broken down into small
vortices. Also, the flow patterns form a tunnel inside the room model. However, the center of the
rotary zones was different. Figure 10 shows the horizontal velocity profiles ratio of different obstacle
control arrangements. It can be seen that when air stream strikes the obstacle, the direction and
magnitude of the original flow velocity are altered and cause changes in the airflow patterns. In this
case, the airflow patterns are forced to diverge and pass around the obstacle edge. Behind the
obstacle, the airflow is unable to come together immediately because of the inertia of the air and a
wake is left where they are separated from the obstacle.
In summary, significant differences in air distribution were found with changes in the
obstacle location and height. Within vortex size and location, remarkable differences were found
between obstacles versus without obstacle airflow. Moreover, installing obstacles inside the building
can be used to create the proper circulation of air through the building and to redirect and concentrate
the air flow along the required zone to provide human comfort.
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
23
(a) Arrangement 1
(b) Arrangement 2
(c) Arrangement 3
(d) Arrangement 4
(e) Arrangement 5
Figure 9: influence of passive control on air flow distribution in single Gutter room model
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
24
(a) roof (b) bottom (c) mid plane
Figure 10: comparison of velocity profiles in single Gutter room model with passive control
4. CONCLUDING REMARKS
The objective of present paper is to computationally investigate the influence of the ceiling
shape design on the flow pattern and velocity distribution. The computational results presented here
gave the detailed insight about the airflow inside 2-D building model configurations. The following
conclusions are drawn based on the results presented:
• The ceiling shape alters the flow inside the room.
• Air dead zone circulation regions are replaced with low speed recirculation zone with
increase in roof angle.
• The passive control in the form of vertical obstacle resulted in better control of air flow when
compared with the room without passive control.
• The increase in roof angle or arc length created a vertex near the roof acting as an insulator
for the heat flow from outside. Vertical obstacles hung from the roof also provided same
results.
The most noticeable aspect is the development of a second area of recirculation closer to roof
and a third area of recirculation on the floor in addition to the under vent vortex.
The predicted velocity profiles showed that
• At small roof-slope angle, the velocity profiles adjacent to the roof are similar.
• The velocity profile after the gable or gutter in combined ceiling shape with flat roof showed
the same air flow pattern.
• The double-gable and double-gutter ceiling room models had significant effect on velocity
profile.
The factors that affect the airflow pattern through the building are the degree of roof slope
and the height and location of obstacle. The effect of roof shape may be used to ensure that air
movement occurs where it is required, for instance near the floor in the occupied zone of the room.
The correct roof shape will ensure that air movement inside the room is enhanced.
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 –
6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME
25
5. REFERENCES
[1] Facr, A., 1990, “Cooling building by natural ventilation,” MIL-HDBK-1011/2, AMSC N/A.
[2] Dr. Ahmed A. Salman, “Numerical prediction of airflow patterns in a 2-d room model under
different ceiling shape with and without passive control”, Proceedings of Seventh
International Congress On Fluid Dynamics and Propulsion December 18-20, 2001, Cairo,
Egypt.
[3] Bjeg, B., Svidt, K., Morsing, S., and Zhang, G., "Optimization of the design of two test
rooms by means of CFD,” Dep. of Agricultural Engineering Danish Institute of Agricultural
Sciences, Research Center, Bygholm, Dk-8700 Horsens, Denmark.
[4] Iannone, F. “Natural ventilation and sustainability: Designing with computational fluid
dynamics,” Via Orabona, 4-70125 Bari, Italy, E-mail: f.iannone@libero.it.
[5] Tarun Singh Tanwar, Dharmendra Hariyani and Manish Dadhich, “Flow Simulation (CFD)
& Static Structural Analysis (FEA) of a Radial Turbine”, International Journal of Mechanical
Engineering & Technology (IJMET), Volume 3, Issue 3, 2012, pp. 252 - 269, ISSN Print:
0976 – 6340, ISSN Online: 0976 – 6359.
[6] P.S. Jeyalaxmi and Dr.G.Kalivarathan, “CFD Analysis of Flow Characteristics in a Gas
Turbine- A Viable Approach to Predict the Turbulence”, International Journal of Mechanical
Engineering & Technology (IJMET), Volume 4, Issue 2, 2013, pp. 39 - 46, ISSN Print:
0976 – 6340, ISSN Online: 0976 – 6359.
[7] M.Z.I.Sajid, Dr. K. Hema Chandra Reddy and Dr. E.L. Nagesh, “Design of Vertical Axis
Wind Turbine for Harnessing Optimum Power”, International Journal of Mechanical
Engineering & Technology (IJMET), Volume 4, Issue 2, 2013, pp. 172 - 177, ISSN Print:
0976 – 6340, ISSN Online: 0976 – 6359.
[8] Nitin Kardekar, Dr. V K Bhojwani and Dr. Sane N K, “Numerical Analysis of Air Flow
Velocity Streamlines of Air Curtains”, International Journal of Mechanical Engineering &
Technology (IJMET), Volume 4, Issue 5, 2013, pp. 150 - 155, ISSN Print: 0976 – 6340,
ISSN Online: 0976 – 6359.
[9] N.S. Venkatesh Kumar and Prof. K. Hema Chandra Reddy, “CFD Analysis of Wind Driven
Natural Cross Ventilation for a Generic Isolated Building”, International Journal of
Mechanical Engineering & Technology (IJMET), Volume 4, Issue 5, 2013, pp. 200 - 207,
ISSN Print: 0976 – 6340, ISSN Online: 0976 – 6359.

More Related Content

PDF
30120140501002
PDF
30120130405023
PDF
Efficient Mass Participation Ratio of Building with Basement
PDF
Effect of Wind Direction through Single Storied Building Model Configurations...
PDF
Cu35540546
PDF
Effect of Wind Direction through Double Storied Building Model Configurations...
PDF
IRJET- Seismic Analysis of Flat Slab Multi-Storey Building with Varying Shear...
PDF
Effects of welding current and arc voltage on fcaw weld bead geometry
30120140501002
30120130405023
Efficient Mass Participation Ratio of Building with Basement
Effect of Wind Direction through Single Storied Building Model Configurations...
Cu35540546
Effect of Wind Direction through Double Storied Building Model Configurations...
IRJET- Seismic Analysis of Flat Slab Multi-Storey Building with Varying Shear...
Effects of welding current and arc voltage on fcaw weld bead geometry

What's hot (20)

PDF
Calculation of Fluid Dynamic for Wind Flow around Reinforced Concrete Walls
PDF
An Experimental Study on Vehicular Emission Dispersion through Single Storied...
PDF
Wind Analysis of Tall Building with Floor Diaphragm
PDF
Heat transfer augmentation in different geometries of dimpled surface under n...
PDF
Heat transfer augmentation in different geometries of dimpled surface under n...
PDF
Effect of wind load on tall buildings in different terrain category
PDF
NSL General HdW.update nov09
PDF
IRJET- Shape Optimization of Corners having Different Radius of High Rise Bui...
PDF
Numerical simulation of wind flow over complex terrain (yangon city)
PPT
Taming The Wind with Engineered Tall Walls
PDF
Study of Comparison Between Static and Dynamic Analysis Subjected to Wind and...
PDF
IRJET- Non-Linear Time History Analysis of the Horizontal and Vertical Asymme...
PDF
Evaluation of punching shear in flat slabs
PDF
Effects of shape on the wind instigate response of high rise buildings
PDF
C030101011016
PDF
ANALYSIS OF WIND & EARTHQUAKE LOAD FOR DIFFERENT SHAPES OF HIGH RISE BUILDING
PDF
Application of extended n2 method to reinforced concrete frames with asymmetr...
PDF
Optimized mould design of an Air cooler tank
PDF
Comparative study of the forces in g+5 and g+10 multi storied buildings subje...
PDF
Improving the Hydraulic Efficiency of Centrifugal Pumps through Computational...
Calculation of Fluid Dynamic for Wind Flow around Reinforced Concrete Walls
An Experimental Study on Vehicular Emission Dispersion through Single Storied...
Wind Analysis of Tall Building with Floor Diaphragm
Heat transfer augmentation in different geometries of dimpled surface under n...
Heat transfer augmentation in different geometries of dimpled surface under n...
Effect of wind load on tall buildings in different terrain category
NSL General HdW.update nov09
IRJET- Shape Optimization of Corners having Different Radius of High Rise Bui...
Numerical simulation of wind flow over complex terrain (yangon city)
Taming The Wind with Engineered Tall Walls
Study of Comparison Between Static and Dynamic Analysis Subjected to Wind and...
IRJET- Non-Linear Time History Analysis of the Horizontal and Vertical Asymme...
Evaluation of punching shear in flat slabs
Effects of shape on the wind instigate response of high rise buildings
C030101011016
ANALYSIS OF WIND & EARTHQUAKE LOAD FOR DIFFERENT SHAPES OF HIGH RISE BUILDING
Application of extended n2 method to reinforced concrete frames with asymmetr...
Optimized mould design of an Air cooler tank
Comparative study of the forces in g+5 and g+10 multi storied buildings subje...
Improving the Hydraulic Efficiency of Centrifugal Pumps through Computational...
Ad

Similar to CFD INVESTIGATION OF CEILING SHAPE ON AIRFLOW DISTRIBUTION FOR A GENERIC 2-D ROOM MODEL WITH AND WITHOUT PASSIVE CONTROL (20)

PDF
45 investigation paper id 0008 edit septian
PDF
N033065072
PDF
BEHAVIOR OF TALL MASONRY CHIMNEYS UNDER WIND LOADINGS USING CFD TECHNIQUE
PDF
A combined cfd network method for the natural air ventilation - icwe13
DOCX
CFD Class Final Paper
PDF
J26048056
PDF
van_hooff_final.pdf
PDF
van_hooff_final.pdf
PDF
20320140502007
PDF
CFD simulation for predicting the wind effect on the high rise building: NET ...
PDF
IRJET- Drag Coefficient of Tall Building by CFD Method using Ansys
PDF
A Pitched Roof with Forced Ventilation to Limit Solar Gains_Crimson Publishers
PDF
Computational Fluid Dynamics (CFD) Analysis of Natural Convection of Converge...
PDF
Estimation of Heat Flux on A Launch Vehicle Fin at Hypersonic Mach Numbers --...
PDF
CFD Analysis of Natural Convection Flow through Inclined Enclosure
PDF
B012511421
PDF
C1304011319
DOCX
Ventilation system of building
PDF
CFD Project
PDF
Journal of energy buildings m carlsson_final
45 investigation paper id 0008 edit septian
N033065072
BEHAVIOR OF TALL MASONRY CHIMNEYS UNDER WIND LOADINGS USING CFD TECHNIQUE
A combined cfd network method for the natural air ventilation - icwe13
CFD Class Final Paper
J26048056
van_hooff_final.pdf
van_hooff_final.pdf
20320140502007
CFD simulation for predicting the wind effect on the high rise building: NET ...
IRJET- Drag Coefficient of Tall Building by CFD Method using Ansys
A Pitched Roof with Forced Ventilation to Limit Solar Gains_Crimson Publishers
Computational Fluid Dynamics (CFD) Analysis of Natural Convection of Converge...
Estimation of Heat Flux on A Launch Vehicle Fin at Hypersonic Mach Numbers --...
CFD Analysis of Natural Convection Flow through Inclined Enclosure
B012511421
C1304011319
Ventilation system of building
CFD Project
Journal of energy buildings m carlsson_final
Ad

More from IAEME Publication (20)

PDF
IAEME_Publication_Call_for_Paper_September_2022.pdf
PDF
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
PDF
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
PDF
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
PDF
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
PDF
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
PDF
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
PDF
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
PDF
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
PDF
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
PDF
GANDHI ON NON-VIOLENT POLICE
PDF
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
PDF
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
PDF
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
PDF
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
PDF
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
PDF
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
PDF
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
PDF
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
PDF
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
IAEME_Publication_Call_for_Paper_September_2022.pdf
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
GANDHI ON NON-VIOLENT POLICE
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT

Recently uploaded (20)

PPTX
Engineering Ethics, Safety and Environment [Autosaved] (1).pptx
PDF
TFEC-4-2020-Design-Guide-for-Timber-Roof-Trusses.pdf
PDF
BIO-INSPIRED HORMONAL MODULATION AND ADAPTIVE ORCHESTRATION IN S-AI-GPT
PPTX
Foundation to blockchain - A guide to Blockchain Tech
PPTX
MET 305 2019 SCHEME MODULE 2 COMPLETE.pptx
PPTX
Sustainable Sites - Green Building Construction
PDF
Model Code of Practice - Construction Work - 21102022 .pdf
PDF
Unit I ESSENTIAL OF DIGITAL MARKETING.pdf
DOCX
ASol_English-Language-Literature-Set-1-27-02-2023-converted.docx
PPTX
bas. eng. economics group 4 presentation 1.pptx
PDF
Embodied AI: Ushering in the Next Era of Intelligent Systems
PPTX
Construction Project Organization Group 2.pptx
PPTX
web development for engineering and engineering
PDF
Mohammad Mahdi Farshadian CV - Prospective PhD Student 2026
PPTX
Geodesy 1.pptx...............................................
PDF
Evaluating the Democratization of the Turkish Armed Forces from a Normative P...
PDF
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf
PPTX
additive manufacturing of ss316l using mig welding
PPTX
FINAL REVIEW FOR COPD DIANOSIS FOR PULMONARY DISEASE.pptx
PPTX
CYBER-CRIMES AND SECURITY A guide to understanding
Engineering Ethics, Safety and Environment [Autosaved] (1).pptx
TFEC-4-2020-Design-Guide-for-Timber-Roof-Trusses.pdf
BIO-INSPIRED HORMONAL MODULATION AND ADAPTIVE ORCHESTRATION IN S-AI-GPT
Foundation to blockchain - A guide to Blockchain Tech
MET 305 2019 SCHEME MODULE 2 COMPLETE.pptx
Sustainable Sites - Green Building Construction
Model Code of Practice - Construction Work - 21102022 .pdf
Unit I ESSENTIAL OF DIGITAL MARKETING.pdf
ASol_English-Language-Literature-Set-1-27-02-2023-converted.docx
bas. eng. economics group 4 presentation 1.pptx
Embodied AI: Ushering in the Next Era of Intelligent Systems
Construction Project Organization Group 2.pptx
web development for engineering and engineering
Mohammad Mahdi Farshadian CV - Prospective PhD Student 2026
Geodesy 1.pptx...............................................
Evaluating the Democratization of the Turkish Armed Forces from a Normative P...
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf
additive manufacturing of ss316l using mig welding
FINAL REVIEW FOR COPD DIANOSIS FOR PULMONARY DISEASE.pptx
CYBER-CRIMES AND SECURITY A guide to understanding

CFD INVESTIGATION OF CEILING SHAPE ON AIRFLOW DISTRIBUTION FOR A GENERIC 2-D ROOM MODEL WITH AND WITHOUT PASSIVE CONTROL

  • 1. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 10 CFD INVESTIGATION OF CEILING SHAPE ON AIRFLOW DISTRIBUTION FOR A GENERIC 2-D ROOM MODEL WITH AND WITHOUT PASSIVE CONTROL N.S.Venkatesh Kumar1 , Prof. K. Hema Chandra Reddy2 1 (Principal, Govt. Polytechnic, Pillaripattu, Nagari, (Chittoor Dist.), A.P., India and Research Scholar, Department of Mechanical Engg, JNTUA, Anantapuram, A.P., India) 2 (Registrar, JNTUA, Anantapuram, A.P., India) ABSTRACT Natural ventilation, which provides occupants with good indoor air quality and a high level of thermal comfort with reduced energy costs, has been drawing utmost importance in sustainable strategy in building designs. Air flow distribution in a 2-D room with cross ventilation under different ceiling shape is investigated in this present paper using computational simulations carried with ANSYS-CFX, commercial CFD software. Investigation of air flow distribution is important to understand convective flow distribution and to control the flow to achieve its effective distribution for human comfort condition. The flow inside a building may be characterized by separation, reattachment, recirculation zone and circulation bubble. Within one room model, airflow patterns are evaluated with and without the presence of an obstacle. The obstacle creates vortex break down thereby creating the necessary high and low air speed zones necessary for comfort conditions when comparison is made for a similar situation without obstacle. The ceiling shape designs investigated in this present paper are Gable single, Gable-flat, Gutter single and Gutter-flat roof structures with and without passive control of air. The roof shape effect on air flow distribution is captured and represented by velocity vectors, streamlines and velocity contours and it is observed that location and the size of the recirculated air variation is sensitive to changes in the building's roof shape and the placement of the obstacle. Key words: Ceiling Shape, Air Flow Distribution, Passive Control and CFD. INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) ISSN 0976 – 6340 (Print) ISSN 0976 – 6359 (Online) Volume 5, Issue 1, January (2014), pp. 10-25 © IAEME: www.iaeme.com/ijmet.asp Journal Impact Factor (2013): 5.7731 (Calculated by GISI) www.jifactor.com IJMET © I A E M E
  • 2. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 11 1. INTRODUCTION The room geometry plays an important role to achieve natural air flow distribution for human comfort conditions. Good survey about building design criteria, features and practices are given by Facr [1]. The flow inside a building may be characterized by separation, reattachment, recirculation zone and circulation bubble. These features can be investigated using simple geometry, two- dimensional flow that makes a very popular numerical research subject. Several factors influence airflow pattern inside a building. These include the configuration, location and structure of air inlets and outlets, the condition of the incoming air and size and shape of building. A recirculation system can be used to distribute air inside the building. Different arrangements of air inlets and recirculation air systems would result in different airflow patterns Dr. Ahmed A. Salman et. al. [2] . Bjeg, et. al. [3] showed that the aspect ratios of the room determined whether the airflow can be two- or three- dimensional. Iannone [3] showed that the building form and the details of the air outlet and inlet systems can remarkably affect the ventilation performance. It is possible to start from a simplified geometry (rectangular room) and modify its form by changing roof slope. Aynsley [4] concluded that despite the powerful tools in the form of zonal network flow analysis, CFD software and LES methods used on large naturally ventilated buildings, there is a need for development of simpler natural ventilation computation method for its use in the preliminary stage of building design of building shape or orientation. In this case, unresolved issues in computation of natural ventilation for thermal comfort were discussed. This paper discusses the airflow pattern, velocity distribution and one of vortex control systems that might be used inside a room for passive control of air. There are various systems for changing velocity vectors and reducing vortex strength. As an air stream approaches a solid fence, it is either forced up and over the obstacle or around it. In buildings with very high ceilings, it is very difficult to maintain the air velocity near floor level. So, baffles can be installed across the building width to reconcentrate the airflow along the floor level and to provide personnel comfort. 2. CFD SIMULATIONS Computational settings and parameters for the reference case are outlined and accordingly the results for this case are presented. Later on, these settings and parameters will be systematically modified for the parametric study. 2.1. Computational domain and grid The dimensions of the generic isolate 2-D building and computational domain were chosen from [2]. The geometry of the room consists of: two vertical walls, horizontal floor and flat, sloping or pitched roofs. The buildings had dimensions W x H = 2.4 x 1m2 and depth of the building is 0.25 m to carry simulations in CFX. The computational grid is made of structured mesh with Hexa grid. The geometry and mesh is generated using ICEM CFD, meshing software.
  • 3. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 12 (a) single Gable room model (b) single Gutter room model (c) single Gutter-Flat room model (d) single Gable-Flat room model (e) single Gable room model with verticle obstacle Figure 1: Structured mesh for different ceiling shape geometries
  • 4. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 13 2.2. Boundary conditions A uniform velocity of 1.725m/s is given at inlet vent as inlet boundary condition. Outlet boundary condition is applied at bottom vent and it is assumed that average static pressure is zero to get normal outlet velocity at outlet. For the floor, vertical wall and roof, the no-slip wall functions are chosen with zero roughness height. The computational domain with boundary condition and velocity profile at inlet is as shown below. Figure 2: Applied Boundary Conditions 2.3. Solver settings The 3D steady RANS equations were solved in combination with the k-ϵ model. Advection scheme adapted for solving momentum governing equations is High resolution and for turbulence equations first order scheme. The convergence criteria are taken as 10-6 . 3. RESULTS AND DISCUSSION Computational investigation of air flow distribution inside a single and double-zone building of different ceiling shape are presented. Four ceiling shapes are computationally modeled. The ceiling geometry specifications are summarized in Table 1. The parameter considered for the computational investigation is roof slope or roof arc length and the inflow and outflow conditions remains same for all the cases. Room ventilation should provide wind in desired direction and no recirculation or dead air zone in occupied regions. To achieve such layouts in practice, obstacles of different height degrees are imposed. For single gable room model, airflow patterns are evaluated with and without the presence of an obstacle. The obstacle was placed either on the floor or hanged from the roof at the plane of symmetry in the middle of the room model. The details of vortex control geometrical arrangement are shown in Table 2.
  • 5. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 14 Table 1: Specifications of the case studies Case No. Roof type Room width [m] Maximum height [m] Roof slope or 1/4 arc angle [degrees] 1 Single gable roof 2.4 1.105 5 1.32154 15 1.69282 30 2 Single gutter roof 2.4 Same as above 3 Gable - Flat roof 4.8 Same as above 4 Gutter - Flat roof 4.8 Same as above Table 2: Arrangements for the placement and height of the vertical obstacle Arrangement No. Obstacle location Obstacle height [m] 1 No obstacle 0.00 2 One obstacle mounted on the floor in the plane of symmetry 0.43 3 One obstacle mounted on the floor in the plane of symmetry 0.86 4 Two obstacles mounted on the floor and hanged from the roof in the plane of symmetry 0.43 for each one 5 One obstacle hanged from the roof in the plane of symmetry 0.86 3. 1. Effect of Different Ceiling slope on Single Gable and Gutter Room Models Computational results presented in this section are for single gable room and single gutter room with the change of roof slope or arc angle. The air flow distribution and velocity profiles are presented in the form of vectors, contours and charts. The plots on the right column show contours. Flow velocity vectors are given in the plot on the left column. In these figures, streamlines that form closed loops indicate zones of recirculation air or vortices. The fact that these recirculation zones have areas with high and low flow velocities is also evident in the velocity vector plots. One of these dominated local vortices occurs in the corner below the inlet edge when the inflow of air is at an angle of 90 degrees to the windward vertical wall irrespective of the roof shape. As the roof slope increases, there is a decrease in the recirculation zone that appeared inside the room as shown in Figures 3-c and 4-c. Results showed that for a gutter with proper height, the air supply flows between the two circulation zones with opposite directions and spreads along the floor before it is drawn to the exhaust side and removed. Figure 5a-c shows the normalized horizontal velocity profiles adjacent to the roof, on the floor and on the plane of symmetry in the middle of the gable (on the left column) and gutter (on the right column) room models. The velocity profiles adjacent to the roof (Figure 5-a) show the sensitivity to the roof shape. Increasing the roof slope angle to 30 degrees shows the same velocity profile for both shapes. Comparison of floor velocity profiles between gable and gutter roof shape at different pitch angle is given in Figure 5-b. At roof slope equal 5 and 15 degrees, the
  • 6. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 15 velocity profiles are almost identical. As the roof angle increased, the reattachment length of the gable model is smaller than that of the gutter model. Figure 5-c shows that, in the plane of symmetry, no considerable difference between the different shapes as the pitch angle or roof arc length increases are observed except at the angle 30 degrees. (a) Roof slope: 5 degrees (b) Roof slope: 10 degrees (c) Roof slope: 15 degrees Figure 3: influence of roof slope angle on air flow distribution in single Gable room model
  • 7. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 16 (a) Arc angle: 20 degrees (b) Arc angle: 60 degrees (c) Arc angle: 120 degrees Figure 4: influence of arc roof angle on air flow distribution in single Gutter room model
  • 8. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 17 (a) comparison of roof velocity profiles (b) comparison of floor velocity profiles (c) comparison of velocity profiles at the middle vertical plane of the room, x=1.2h Figure 5: horizontal velocity profile, U/Uin 3. 2. Effect of roof slope or arc angle on Single Gable-flat and Gutter-flat Room Models The results represented here in form of velocity vector and contour in Figures 6a-c and 7a-c shows the airflow patterns for three cases of gable-flat and gutter-flat room models. For all models, one can observe the development of different vortex circulation zones. The flow is attached to the roof at small roof angles or arc lengths and detaching from the wall nearer to the exit forming large
  • 9. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 18 vortex region just below the inlet vent and there is a low velocity circulation region at the floor as it is observed in Figures 6-a and 7-a. As the roof angle increases, the flow detachment from the top wall occurred much before exit, it is attached to the floor and there is a recirculation or dead zone region just below the roof. The three recirculation zones as observed in room are shown in Fig. 6-c and 7-c. In this type of ceiling shape, most of the action occurred in the gable or the gutter regions, while the airflow pattern is nearly uniform through the flat region. Further investigation showed that the velocity vector length increased at the connecting joint between gable or gutter and flat roof surface. Moreover, subdivision of the flow into near-wall jet and a relatively low-speed circulation flow is mostly distinct. For both gable and gutter flow models, the within-jet velocity keeps high values up to the exit from the under gutter roof region and then becomes almost uniform till the exit. The side-by-side comparison of the velocity profiles at different planes for gable-flat and gutter-flat room models of three different ceiling shapes are shown in Figure 8a-c. In these figures, the velocity profiles adjacent to the ceiling, on the floor and at a distance equal 1.2 h from the inlet vent for these three different arrangements are presented. According to Figure 8-a, the normalized velocity profiles decrease at constant rate to the exit and there is a slightly increase in profile at the middle of gable and gutter. As the roof angle or arc length increases, there is a sharp decrease in velocity ratio until the roof vertex angle of the gable zone and then increase in its value up to connection of gable and flat roof, and then decrease until towards the exit from the room. Similar behavior is observed for gutter-flat room model. Figure 8-b shows that at roof slope equal 5 degrees and 10 degrees, the velocity profiles are almost identical. For both gable-flat and gutter-flat models, the velocity profiles show no significant effect in the flat ceiling zone. Figure 8-c shows that the typical shape of velocity profiles along the plane of symmetry is maintained and reflects the size of the recirculation zones. (a) Roof slope: 5 degrees
  • 10. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 19 (b) Roof slope: 10 degrees (c) Roof slope: 15 degrees Figure 6: influence of roof slope on air flow distribution in single Gable-Flat room model
  • 11. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 20 (a) Arc angle: 20 degrees (b) Arc angle: 60 degrees
  • 12. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 21 (c) Arc angle: 120 degrees Figure 7: influence of arc roof angle on air flow distribution in single Gutter-Flat room model (a) comparison of roof velocity profiles (b) comparison of floor velocity profiles
  • 13. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 22 (c) Comparison of velocity profiles at the middle vertical plane of the room, x=1.2h Figure 8: horizontal velocity profile, U/Uin 3. 3. Effect of Vertical Obstacle (Passive Control) Moving air has momentum and it will keep on moving in a particular direction until it is turned by an obstacle as considered in a passive control system. Attention therefore must be given to the obstacle location and height, to create the needed high and low air speed zones. Five different arrangements for the placement and height of the vertical obstacle are given in Table 2. Figures 9a-e presents the velocity vectors inside the single gable room model with roof slope equal 15o (left side) and the velocity contours (right side) adjacent to the roof and on the floor of that model. Figure 10a-c shows velocity profiles, at the middle plane of the room, for five different arrangements. Due to the deflection of air through the room, the airflow patterns for the last four arrangements were quite different from the one obtained without obstacle (arrangement one). Figure 9-b and 9-c show that as the obstacle is getting higher and higher, the airflow pattern and the original big vortex gets split into two vortices on the right and left of the obstacle. The velocity vectors and velocity profiles show that the zone at the left side of the vertical obstacle has different rotational strength than that of the zone at the right side. The flow patterns for the fifth arrangement are similar to the arrangement of the other four. However, the centers of the rotary zones are different. When the obstacle hanged from the roof, as shown in Figure 9-d and 9-e, the big circulation zone near the roof is broken down into small vortices. Also, the flow patterns form a tunnel inside the room model. However, the center of the rotary zones was different. Figure 10 shows the horizontal velocity profiles ratio of different obstacle control arrangements. It can be seen that when air stream strikes the obstacle, the direction and magnitude of the original flow velocity are altered and cause changes in the airflow patterns. In this case, the airflow patterns are forced to diverge and pass around the obstacle edge. Behind the obstacle, the airflow is unable to come together immediately because of the inertia of the air and a wake is left where they are separated from the obstacle. In summary, significant differences in air distribution were found with changes in the obstacle location and height. Within vortex size and location, remarkable differences were found between obstacles versus without obstacle airflow. Moreover, installing obstacles inside the building can be used to create the proper circulation of air through the building and to redirect and concentrate the air flow along the required zone to provide human comfort.
  • 14. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 23 (a) Arrangement 1 (b) Arrangement 2 (c) Arrangement 3 (d) Arrangement 4 (e) Arrangement 5 Figure 9: influence of passive control on air flow distribution in single Gutter room model
  • 15. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 24 (a) roof (b) bottom (c) mid plane Figure 10: comparison of velocity profiles in single Gutter room model with passive control 4. CONCLUDING REMARKS The objective of present paper is to computationally investigate the influence of the ceiling shape design on the flow pattern and velocity distribution. The computational results presented here gave the detailed insight about the airflow inside 2-D building model configurations. The following conclusions are drawn based on the results presented: • The ceiling shape alters the flow inside the room. • Air dead zone circulation regions are replaced with low speed recirculation zone with increase in roof angle. • The passive control in the form of vertical obstacle resulted in better control of air flow when compared with the room without passive control. • The increase in roof angle or arc length created a vertex near the roof acting as an insulator for the heat flow from outside. Vertical obstacles hung from the roof also provided same results. The most noticeable aspect is the development of a second area of recirculation closer to roof and a third area of recirculation on the floor in addition to the under vent vortex. The predicted velocity profiles showed that • At small roof-slope angle, the velocity profiles adjacent to the roof are similar. • The velocity profile after the gable or gutter in combined ceiling shape with flat roof showed the same air flow pattern. • The double-gable and double-gutter ceiling room models had significant effect on velocity profile. The factors that affect the airflow pattern through the building are the degree of roof slope and the height and location of obstacle. The effect of roof shape may be used to ensure that air movement occurs where it is required, for instance near the floor in the occupied zone of the room. The correct roof shape will ensure that air movement inside the room is enhanced.
  • 16. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online) Volume 5, Issue 1, January (2014), © IAEME 25 5. REFERENCES [1] Facr, A., 1990, “Cooling building by natural ventilation,” MIL-HDBK-1011/2, AMSC N/A. [2] Dr. Ahmed A. Salman, “Numerical prediction of airflow patterns in a 2-d room model under different ceiling shape with and without passive control”, Proceedings of Seventh International Congress On Fluid Dynamics and Propulsion December 18-20, 2001, Cairo, Egypt. [3] Bjeg, B., Svidt, K., Morsing, S., and Zhang, G., "Optimization of the design of two test rooms by means of CFD,” Dep. of Agricultural Engineering Danish Institute of Agricultural Sciences, Research Center, Bygholm, Dk-8700 Horsens, Denmark. [4] Iannone, F. “Natural ventilation and sustainability: Designing with computational fluid dynamics,” Via Orabona, 4-70125 Bari, Italy, E-mail: f.iannone@libero.it. [5] Tarun Singh Tanwar, Dharmendra Hariyani and Manish Dadhich, “Flow Simulation (CFD) & Static Structural Analysis (FEA) of a Radial Turbine”, International Journal of Mechanical Engineering & Technology (IJMET), Volume 3, Issue 3, 2012, pp. 252 - 269, ISSN Print: 0976 – 6340, ISSN Online: 0976 – 6359. [6] P.S. Jeyalaxmi and Dr.G.Kalivarathan, “CFD Analysis of Flow Characteristics in a Gas Turbine- A Viable Approach to Predict the Turbulence”, International Journal of Mechanical Engineering & Technology (IJMET), Volume 4, Issue 2, 2013, pp. 39 - 46, ISSN Print: 0976 – 6340, ISSN Online: 0976 – 6359. [7] M.Z.I.Sajid, Dr. K. Hema Chandra Reddy and Dr. E.L. Nagesh, “Design of Vertical Axis Wind Turbine for Harnessing Optimum Power”, International Journal of Mechanical Engineering & Technology (IJMET), Volume 4, Issue 2, 2013, pp. 172 - 177, ISSN Print: 0976 – 6340, ISSN Online: 0976 – 6359. [8] Nitin Kardekar, Dr. V K Bhojwani and Dr. Sane N K, “Numerical Analysis of Air Flow Velocity Streamlines of Air Curtains”, International Journal of Mechanical Engineering & Technology (IJMET), Volume 4, Issue 5, 2013, pp. 150 - 155, ISSN Print: 0976 – 6340, ISSN Online: 0976 – 6359. [9] N.S. Venkatesh Kumar and Prof. K. Hema Chandra Reddy, “CFD Analysis of Wind Driven Natural Cross Ventilation for a Generic Isolated Building”, International Journal of Mechanical Engineering & Technology (IJMET), Volume 4, Issue 5, 2013, pp. 200 - 207, ISSN Print: 0976 – 6340, ISSN Online: 0976 – 6359.