10
Most read
20
Most read
21
Most read
Chapter 10
VAPOR AND COMBINED
POWER CYCLES
Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Thermodynamics: An Engineering Approach, 6th Edition
Yunus A. Cengel, Michael A. Boles
McGraw-Hill, 2008
2
Objectives
• Analyze vapor power cycles in which the working fluid
is alternately vaporized and condensed.
• Analyze power generation coupled with process
heating called cogeneration.
• Investigate ways to modify the basic Rankine vapor
power cycle to increase the cycle thermal efficiency.
• Analyze the reheat and regenerative vapor power
cycles.
• Analyze power cycles that consist of two separate
cycles known as combined cycles and binary cycles.
3
THE CARNOT VAPOR CYCLE
T-s diagram of two Carnot vapor cycles.
The Carnot cycle is the most efficient cycle operating between two specified temperature
limits but it is not a suitable model for power cycles. Because:
Process 1-2 Limiting the heat transfer processes to two-phase systems severely limits the
maximum temperature that can be used in the cycle (374°C for water)
Process 2-3 The turbine cannot handle steam with a high moisture content because of the
impingement of liquid droplets on the turbine blades causing erosion and wear.
Process 4-1 It is not practical to design a compressor that handles two phases.
The cycle in (b) is not suitable since it requires isentropic compression to
extremely high pressures and isothermal heat transfer at variable pressures.
1-2 isothermal heat
addition in a boiler
2-3 isentropic expansion
in a turbine
3-4 isothermal heat
rejection in a condenser
4-1 isentropic
compression in a
compressor
4
RANKINE CYCLE: THE IDEAL CYCLE
FOR VAPOR POWER CYCLES
Many of the impracticalities associated with the Carnot cycle can be eliminated
by superheating the steam in the boiler and condensing it completely in the
condenser. The cycle that results is the Rankine cycle, which is the ideal cycle
for vapor power plants. The ideal Rankine cycle does not involve any internal
irreversibilities.
The simple ideal Rankine cycle.
5
Energy Analysis of the Ideal Rankine Cycle
The efficiency of power plants in
the U.S. is often expressed in
terms of heat rate, which is the
amount of heat supplied, in Btu’s,
to generate 1 kWh of electricity.
The thermal efficiency can be interpreted
as the ratio of the area enclosed by the
cycle on a T-s diagram to the area under
the heat-addition process.
Steady-flow energy equation
6
DEVIATION OF ACTUAL VAPOR POWER
CYCLES FROM IDEALIZED ONES
(a) Deviation of actual vapor power cycle from the ideal Rankine cycle.
(b) The effect of pump and turbine irreversibilities on the ideal Rankine cycle.
The actual vapor power cycle differs from the ideal Rankine cycle as a
result of irreversibilities in various components.
Fluid friction and heat loss to the surroundings are the two common
sources of irreversibilities. Isentropic efficiencies
7
HOW CAN WE INCREASE THE EFFICIENCY OF THE
RANKINE CYCLE?
The effect of lowering the
condenser pressure on the
ideal Rankine cycle.
The basic idea behind all the modifications to increase the thermal efficiency
of a power cycle is the same: Increase the average temperature at which heat is
transferred to the working fluid in the boiler, or decrease the average
temperature at which heat is rejected from the working fluid in the condenser.
Lowering the Condenser Pressure (Lowers Tlow,avg)
To take advantage of the increased
efficiencies at low pressures, the condensers
of steam power plants usually operate well
below the atmospheric pressure. There is a
lower limit to this pressure depending on the
temperature of the cooling medium
Side effect: Lowering the condenser
pressure increases the moisture content of
the steam at the final stages of the turbine.
8
The effect of superheating the
steam to higher temperatures
on the ideal Rankine cycle.
Superheating the Steam to High Temperatures
(Increases Thigh,avg)
Both the net work and heat input
increase as a result of superheating
the steam to a higher temperature.
The overall effect is an increase in
thermal efficiency since the average
temperature at which heat is added
increases.
Superheating to higher temperatures
decreases the moisture content of the
steam at the turbine exit, which is
desirable.
The temperature is limited by
metallurgical considerations. Presently
the highest steam temperature allowed
at the turbine inlet is about 620°C.
9
Increasing the Boiler Pressure (Increases Thigh,avg)
The effect of increasing the boiler
pressure on the ideal Rankine cycle.
For a fixed turbine inlet temperature,
the cycle shifts to the left and the
moisture content of steam at the
turbine exit increases. This side
effect can be corrected by reheating
the steam.
A supercritical Rankine cycle.
Today many modern steam power
plants operate at supercritical
pressures (P > 22.06 MPa) and
have thermal efficiencies of about
40% for fossil-fuel plants and 34%
for nuclear plants.
10
THE IDEAL REHEAT RANKINE CYCLE
How can we take advantage of the increased efficiencies at higher boiler pressures
without facing the problem of excessive moisture at the final stages of the turbine?
1. Superheat the steam to very high temperatures. It is limited metallurgically.
2. Expand the steam in the turbine in two stages, and reheat it in between (reheat)
The ideal reheat Rankine cycle.
11
The average temperature at
which heat is transferred during
reheating increases as the
number of reheat stages is
increased.
The single reheat in a modern power
plant improves the cycle efficiency by 4 to
5% by increasing the average
temperature at which heat is transferred
to the steam.
The average temperature during the
reheat process can be increased by
increasing the number of expansion and
reheat stages. As the number of stages is
increased, the expansion and reheat
processes approach an isothermal
process at the maximum temperature.
The use of more than two reheat stages
is not practical. The theoretical
improvement in efficiency from the
second reheat is about half of that which
results from a single reheat.
The reheat temperatures are very close
or equal to the turbine inlet temperature.
The optimum reheat pressure is about
one-fourth of the maximum cycle
pressure.
12
THE IDEAL REGENERATIVE RANKINE CYCLE
The first part of the heat-addition
process in the boiler takes place at
relatively low temperatures.
Heat is transferred to the working fluid
during process 2-2’ at a relatively low
temperature. This lowers the average
heat-addition temperature and thus the
cycle efficiency.
In steam power plants, steam is extracted
from the turbine at various points. This
steam, which could have produced more
work by expanding further in the turbine, is
used to heat the feedwater instead. The
device where the feedwater is heated by
regeneration is called a regenerator, or a
feedwater heater (FWH).
A feedwater heater is basically a heat
exchanger where heat is transferred from
the steam to the feedwater either by
mixing the two fluid streams (open
feedwater heaters) or without mixing them
(closed feedwater heaters).
13
Open Feedwater Heaters
The ideal regenerative Rankine cycle with an open feedwater heater.
An open (or direct-contact) feedwater
heater is basically a mixing chamber,
where the steam extracted from the
turbine mixes with the feedwater exiting
the pump. Ideally, the mixture leaves
the heater as a saturated liquid at the
heater pressure.
14
Closed Feedwater Heaters
The ideal regenerative Rankine cycle with a closed feedwater heater.
Another type of feedwater heater frequently used in steam power plants is
the closed feedwater heater, in which heat is transferred from the
extracted steam to the feedwater without any mixing taking place. The two
streams now can be at different pressures, since they do not mix.
15
A steam power plant with one open
and three closed feedwater heaters.
The closed feedwater heaters are more complex because of the internal tubing
network, and thus they are more expensive. Heat transfer in closed feedwater
heaters is less effective since the two streams are not allowed to be in direct contact.
However, closed feedwater heaters do not require a separate pump for each heater
since the extracted steam and the feedwater can be at different pressures.
Open feedwater
heaters are simple
and inexpensive
and have good
heat transfer
characteristics. For
each heater,
however, a pump is
required to handle
the feedwater.
Most steam power
plants use a
combination of
open and closed
feedwater heaters.
16
SECOND-LAW ANALYSIS OF VAPOR
POWER CYCLES
Exergy destruction for a steady-flow system
Steady-flow, one-
inlet, one-exit
Exergy destruction of a cycle
For a cycle with heat transfer
only with a source and a sink
Stream exergy
A second-law analysis of vaporpower cycles reveals where the
largest irreversibilities occur and where to start improvements.
17
COGENERATION
A simple process-heating plant.
Many industries require energy input in the form of heat, called process
heat. Process heat in these industries is usually supplied by steam at 5 to
7 atm and 150 to 200°C. Energy is usually transferred to the steam by
burning coal, oil, natural gas, or another fuel in a furnace.
Industries that use large amounts
of process heat also consume a
large amount of electric power.
It makes sense to use the already-
existing work potential to produce
power instead of letting it go to
waste.
The result is a plant that produces
electricity while meeting the
process-heat requirements of
certain industrial processes
(cogeneration plant)
Cogeneration: The production of more than one useful form of energy
(such as process heat and electric power) from the same energy source.
18
An ideal cogeneration plant.
Utilization
factor
• The utilization factor of the
ideal steam-turbine
cogeneration plant is
100%.
• Actual cogeneration plants
have utilization factors as
high as 80%.
• Some recent cogeneration
plants have even higher
utilization factors.
19
A cogeneration plant with
adjustable loads.
At times of high demand for process heat, all
the steam is routed to the process-heating units
and none to the condenser (m7= 0). The waste
heat is zero in this mode.
If this is not sufficient, some steam leaving the
boiler is throttled by an expansion or pressure-
reducing valve to the extraction pressure P6
and is directed to the process-heating unit.
Maximum process heating is realized when all
the steam leaving the boiler passes through the
PRV (m5= m4). No power is produced in this
mode.
When there is no demand for process heat, all
the steam passes through the turbine and the
condenser (m5=m6=0), and the cogeneration
plant operates as an ordinary steam power
plant.
20
COMBINED GAS–VAPOR POWER CYCLES
• The continued quest for higher thermal efficiencies has resulted in rather
innovative modifications to conventional power plants.
• A popular modification involves a gas power cycle topping a vapor power cycle,
which is called the combined gas–vapor cycle, or just the combined cycle.
• The combined cycle of greatest interest is the gas-turbine (Brayton) cycle topping
a steam-turbine (Rankine) cycle, which has a higher thermal efficiency than
either of the cycles executed individually.
• It makes engineering sense to take advantage of the very desirable
characteristics of the gas-turbine cycle at high temperatures and to use the high-
temperature exhaust gases as the energy source for the bottoming cycle such as
a steam power cycle. The result is a combined gas–steam cycle.
• Recent developments in gas-turbine technology have made the combined gas–
steam cycle economically very attractive.
• The combined cycle increases the efficiency without increasing the initial cost
greatly. Consequently, many new power plants operate on combined cycles, and
many more existing steam- or gas-turbine plants are being converted to
combined-cycle power plants.
• Thermal efficiencies over 50% are reported.
21
Combined gas–steam power plant.
22
Summary
• The Carnot vapor cycle
• Rankine cycle: The ideal cycle for vapor power cycles
 Energy analysis of the ideal Rankine cycle
• Deviation of actual vapor power cycles from idealized ones
• How can we increase the efficiency of the Rankine cycle?
 Lowering the condenser pressure (Lowers Tlow,avg)
 Superheating the steam to high temperatures (Increases Thigh,avg)
 Increasing the boiler pressure (Increases Thigh,avg)
• The ideal reheat Rankine cycle
• The ideal regenerative Rankine cycle
 Open feedwater heaters
 Closed feedwater heaters
• Second-law analysis of vapor power cycles
• Cogeneration
• Combined gas–vapor power cycles

More Related Content

PPT
Rankine cycle
PPSX
PPTX
boiler & classification of boiler
PPT
Regenerative rankine cycle - Complete Overview
PPT
Regenerative rankine cycle (Closed Feedwater Heaters)
PPTX
Vapour power cycles
PPT
Pelton turbine (1)
Rankine cycle
boiler & classification of boiler
Regenerative rankine cycle - Complete Overview
Regenerative rankine cycle (Closed Feedwater Heaters)
Vapour power cycles
Pelton turbine (1)

What's hot (20)

PPT
[PPT] on Steam Turbine
PPT
STEAM POWER PLANT
PPTX
problems on steam cycle
PPTX
Vapor Compression Refrigeration System
PDF
EXPERIMENTAL ANALYSIS OF A MINI STEAM POWER PLANT
PPTX
Steam Turbines
PDF
Separating and throttling calorimeter for steam
PPS
Steam Boilers OR Steam Generators
PDF
Fundamentals of Heat Exchanger Design
PPSX
Steam generator part 2
PPT
Steam Turbines Basics
PPTX
Steam Formation
DOCX
Lab 1 the dryness fraction of the steam(mech)
PPTX
Boiler performance (Part 2) - Boiler efficiency, Boiler trial and Heat balance
PDF
Draught and its classification (notes)
PDF
2151909 heat transfer e-note (thefreestudy.com) (1)
DOCX
Refrigeration system 2
PDF
Boiler performance (Part 1) - Equivalent evaporation - Notes
PPT
Stirling cycle & its applications
PDF
Hydro electric power plant
[PPT] on Steam Turbine
STEAM POWER PLANT
problems on steam cycle
Vapor Compression Refrigeration System
EXPERIMENTAL ANALYSIS OF A MINI STEAM POWER PLANT
Steam Turbines
Separating and throttling calorimeter for steam
Steam Boilers OR Steam Generators
Fundamentals of Heat Exchanger Design
Steam generator part 2
Steam Turbines Basics
Steam Formation
Lab 1 the dryness fraction of the steam(mech)
Boiler performance (Part 2) - Boiler efficiency, Boiler trial and Heat balance
Draught and its classification (notes)
2151909 heat transfer e-note (thefreestudy.com) (1)
Refrigeration system 2
Boiler performance (Part 1) - Equivalent evaporation - Notes
Stirling cycle & its applications
Hydro electric power plant
Ad

Similar to Chapter 10 lecture (20)

PPT
Power cycles
PDF
report final
PPTX
Chapter 10_02.05.2023 Thermodynamics .pptx
PDF
Performance Analysis of Power Plant Systems
PPTX
Vapor_power cycles KM.pptx ..
PPTX
Improvement of rankine efficinecy of steam power plants
PPTX
Chapter 10_04.05.2023 Thermodynamics .pptx
PDF
Vapour power cycle thermo veer ME201 PPT
DOCX
Thermal power plant
DOCX
Academic project report
PDF
NTPC Project KORBA(SUPER THEMAL POWER PLANT)
PPTX
MET 401 Chapter 2 improvement_to_rankine_cycle
PPTX
551 lecture slides.pptx. thermodynamic summary
PPTX
steam power plant
PPTX
steam turbine[1] (3).pptxshshshhhshshshh
PDF
Steam power plant
PPTX
Thermal Power Plant - Full Detail About Plant and Parts (Also Contain Animate...
PDF
Unit_2_58.pdf
DOCX
Rnakine reheat regen
DOCX
Ganesh final report
Power cycles
report final
Chapter 10_02.05.2023 Thermodynamics .pptx
Performance Analysis of Power Plant Systems
Vapor_power cycles KM.pptx ..
Improvement of rankine efficinecy of steam power plants
Chapter 10_04.05.2023 Thermodynamics .pptx
Vapour power cycle thermo veer ME201 PPT
Thermal power plant
Academic project report
NTPC Project KORBA(SUPER THEMAL POWER PLANT)
MET 401 Chapter 2 improvement_to_rankine_cycle
551 lecture slides.pptx. thermodynamic summary
steam power plant
steam turbine[1] (3).pptxshshshhhshshshh
Steam power plant
Thermal Power Plant - Full Detail About Plant and Parts (Also Contain Animate...
Unit_2_58.pdf
Rnakine reheat regen
Ganesh final report
Ad

Recently uploaded (20)

PDF
A contest of sentiment analysis: k-nearest neighbor versus neural network
PDF
sustainability-14-14877-v2.pddhzftheheeeee
PDF
CloudStack 4.21: First Look Webinar slides
PDF
DASA ADMISSION 2024_FirstRound_FirstRank_LastRank.pdf
PDF
Zenith AI: Advanced Artificial Intelligence
PDF
Unlock new opportunities with location data.pdf
PPTX
Final SEM Unit 1 for mit wpu at pune .pptx
PDF
WOOl fibre morphology and structure.pdf for textiles
PDF
August Patch Tuesday
PDF
Developing a website for English-speaking practice to English as a foreign la...
PPTX
Chapter 5: Probability Theory and Statistics
PDF
From MVP to Full-Scale Product A Startup’s Software Journey.pdf
PDF
Microsoft Solutions Partner Drive Digital Transformation with D365.pdf
PPTX
observCloud-Native Containerability and monitoring.pptx
PDF
Hindi spoken digit analysis for native and non-native speakers
PDF
Enhancing emotion recognition model for a student engagement use case through...
PPTX
Benefits of Physical activity for teenagers.pptx
PPTX
Group 1 Presentation -Planning and Decision Making .pptx
PDF
TrustArc Webinar - Click, Consent, Trust: Winning the Privacy Game
PDF
DP Operators-handbook-extract for the Mautical Institute
A contest of sentiment analysis: k-nearest neighbor versus neural network
sustainability-14-14877-v2.pddhzftheheeeee
CloudStack 4.21: First Look Webinar slides
DASA ADMISSION 2024_FirstRound_FirstRank_LastRank.pdf
Zenith AI: Advanced Artificial Intelligence
Unlock new opportunities with location data.pdf
Final SEM Unit 1 for mit wpu at pune .pptx
WOOl fibre morphology and structure.pdf for textiles
August Patch Tuesday
Developing a website for English-speaking practice to English as a foreign la...
Chapter 5: Probability Theory and Statistics
From MVP to Full-Scale Product A Startup’s Software Journey.pdf
Microsoft Solutions Partner Drive Digital Transformation with D365.pdf
observCloud-Native Containerability and monitoring.pptx
Hindi spoken digit analysis for native and non-native speakers
Enhancing emotion recognition model for a student engagement use case through...
Benefits of Physical activity for teenagers.pptx
Group 1 Presentation -Planning and Decision Making .pptx
TrustArc Webinar - Click, Consent, Trust: Winning the Privacy Game
DP Operators-handbook-extract for the Mautical Institute

Chapter 10 lecture

  • 1. Chapter 10 VAPOR AND COMBINED POWER CYCLES Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display. Thermodynamics: An Engineering Approach, 6th Edition Yunus A. Cengel, Michael A. Boles McGraw-Hill, 2008
  • 2. 2 Objectives • Analyze vapor power cycles in which the working fluid is alternately vaporized and condensed. • Analyze power generation coupled with process heating called cogeneration. • Investigate ways to modify the basic Rankine vapor power cycle to increase the cycle thermal efficiency. • Analyze the reheat and regenerative vapor power cycles. • Analyze power cycles that consist of two separate cycles known as combined cycles and binary cycles.
  • 3. 3 THE CARNOT VAPOR CYCLE T-s diagram of two Carnot vapor cycles. The Carnot cycle is the most efficient cycle operating between two specified temperature limits but it is not a suitable model for power cycles. Because: Process 1-2 Limiting the heat transfer processes to two-phase systems severely limits the maximum temperature that can be used in the cycle (374°C for water) Process 2-3 The turbine cannot handle steam with a high moisture content because of the impingement of liquid droplets on the turbine blades causing erosion and wear. Process 4-1 It is not practical to design a compressor that handles two phases. The cycle in (b) is not suitable since it requires isentropic compression to extremely high pressures and isothermal heat transfer at variable pressures. 1-2 isothermal heat addition in a boiler 2-3 isentropic expansion in a turbine 3-4 isothermal heat rejection in a condenser 4-1 isentropic compression in a compressor
  • 4. 4 RANKINE CYCLE: THE IDEAL CYCLE FOR VAPOR POWER CYCLES Many of the impracticalities associated with the Carnot cycle can be eliminated by superheating the steam in the boiler and condensing it completely in the condenser. The cycle that results is the Rankine cycle, which is the ideal cycle for vapor power plants. The ideal Rankine cycle does not involve any internal irreversibilities. The simple ideal Rankine cycle.
  • 5. 5 Energy Analysis of the Ideal Rankine Cycle The efficiency of power plants in the U.S. is often expressed in terms of heat rate, which is the amount of heat supplied, in Btu’s, to generate 1 kWh of electricity. The thermal efficiency can be interpreted as the ratio of the area enclosed by the cycle on a T-s diagram to the area under the heat-addition process. Steady-flow energy equation
  • 6. 6 DEVIATION OF ACTUAL VAPOR POWER CYCLES FROM IDEALIZED ONES (a) Deviation of actual vapor power cycle from the ideal Rankine cycle. (b) The effect of pump and turbine irreversibilities on the ideal Rankine cycle. The actual vapor power cycle differs from the ideal Rankine cycle as a result of irreversibilities in various components. Fluid friction and heat loss to the surroundings are the two common sources of irreversibilities. Isentropic efficiencies
  • 7. 7 HOW CAN WE INCREASE THE EFFICIENCY OF THE RANKINE CYCLE? The effect of lowering the condenser pressure on the ideal Rankine cycle. The basic idea behind all the modifications to increase the thermal efficiency of a power cycle is the same: Increase the average temperature at which heat is transferred to the working fluid in the boiler, or decrease the average temperature at which heat is rejected from the working fluid in the condenser. Lowering the Condenser Pressure (Lowers Tlow,avg) To take advantage of the increased efficiencies at low pressures, the condensers of steam power plants usually operate well below the atmospheric pressure. There is a lower limit to this pressure depending on the temperature of the cooling medium Side effect: Lowering the condenser pressure increases the moisture content of the steam at the final stages of the turbine.
  • 8. 8 The effect of superheating the steam to higher temperatures on the ideal Rankine cycle. Superheating the Steam to High Temperatures (Increases Thigh,avg) Both the net work and heat input increase as a result of superheating the steam to a higher temperature. The overall effect is an increase in thermal efficiency since the average temperature at which heat is added increases. Superheating to higher temperatures decreases the moisture content of the steam at the turbine exit, which is desirable. The temperature is limited by metallurgical considerations. Presently the highest steam temperature allowed at the turbine inlet is about 620°C.
  • 9. 9 Increasing the Boiler Pressure (Increases Thigh,avg) The effect of increasing the boiler pressure on the ideal Rankine cycle. For a fixed turbine inlet temperature, the cycle shifts to the left and the moisture content of steam at the turbine exit increases. This side effect can be corrected by reheating the steam. A supercritical Rankine cycle. Today many modern steam power plants operate at supercritical pressures (P > 22.06 MPa) and have thermal efficiencies of about 40% for fossil-fuel plants and 34% for nuclear plants.
  • 10. 10 THE IDEAL REHEAT RANKINE CYCLE How can we take advantage of the increased efficiencies at higher boiler pressures without facing the problem of excessive moisture at the final stages of the turbine? 1. Superheat the steam to very high temperatures. It is limited metallurgically. 2. Expand the steam in the turbine in two stages, and reheat it in between (reheat) The ideal reheat Rankine cycle.
  • 11. 11 The average temperature at which heat is transferred during reheating increases as the number of reheat stages is increased. The single reheat in a modern power plant improves the cycle efficiency by 4 to 5% by increasing the average temperature at which heat is transferred to the steam. The average temperature during the reheat process can be increased by increasing the number of expansion and reheat stages. As the number of stages is increased, the expansion and reheat processes approach an isothermal process at the maximum temperature. The use of more than two reheat stages is not practical. The theoretical improvement in efficiency from the second reheat is about half of that which results from a single reheat. The reheat temperatures are very close or equal to the turbine inlet temperature. The optimum reheat pressure is about one-fourth of the maximum cycle pressure.
  • 12. 12 THE IDEAL REGENERATIVE RANKINE CYCLE The first part of the heat-addition process in the boiler takes place at relatively low temperatures. Heat is transferred to the working fluid during process 2-2’ at a relatively low temperature. This lowers the average heat-addition temperature and thus the cycle efficiency. In steam power plants, steam is extracted from the turbine at various points. This steam, which could have produced more work by expanding further in the turbine, is used to heat the feedwater instead. The device where the feedwater is heated by regeneration is called a regenerator, or a feedwater heater (FWH). A feedwater heater is basically a heat exchanger where heat is transferred from the steam to the feedwater either by mixing the two fluid streams (open feedwater heaters) or without mixing them (closed feedwater heaters).
  • 13. 13 Open Feedwater Heaters The ideal regenerative Rankine cycle with an open feedwater heater. An open (or direct-contact) feedwater heater is basically a mixing chamber, where the steam extracted from the turbine mixes with the feedwater exiting the pump. Ideally, the mixture leaves the heater as a saturated liquid at the heater pressure.
  • 14. 14 Closed Feedwater Heaters The ideal regenerative Rankine cycle with a closed feedwater heater. Another type of feedwater heater frequently used in steam power plants is the closed feedwater heater, in which heat is transferred from the extracted steam to the feedwater without any mixing taking place. The two streams now can be at different pressures, since they do not mix.
  • 15. 15 A steam power plant with one open and three closed feedwater heaters. The closed feedwater heaters are more complex because of the internal tubing network, and thus they are more expensive. Heat transfer in closed feedwater heaters is less effective since the two streams are not allowed to be in direct contact. However, closed feedwater heaters do not require a separate pump for each heater since the extracted steam and the feedwater can be at different pressures. Open feedwater heaters are simple and inexpensive and have good heat transfer characteristics. For each heater, however, a pump is required to handle the feedwater. Most steam power plants use a combination of open and closed feedwater heaters.
  • 16. 16 SECOND-LAW ANALYSIS OF VAPOR POWER CYCLES Exergy destruction for a steady-flow system Steady-flow, one- inlet, one-exit Exergy destruction of a cycle For a cycle with heat transfer only with a source and a sink Stream exergy A second-law analysis of vaporpower cycles reveals where the largest irreversibilities occur and where to start improvements.
  • 17. 17 COGENERATION A simple process-heating plant. Many industries require energy input in the form of heat, called process heat. Process heat in these industries is usually supplied by steam at 5 to 7 atm and 150 to 200°C. Energy is usually transferred to the steam by burning coal, oil, natural gas, or another fuel in a furnace. Industries that use large amounts of process heat also consume a large amount of electric power. It makes sense to use the already- existing work potential to produce power instead of letting it go to waste. The result is a plant that produces electricity while meeting the process-heat requirements of certain industrial processes (cogeneration plant) Cogeneration: The production of more than one useful form of energy (such as process heat and electric power) from the same energy source.
  • 18. 18 An ideal cogeneration plant. Utilization factor • The utilization factor of the ideal steam-turbine cogeneration plant is 100%. • Actual cogeneration plants have utilization factors as high as 80%. • Some recent cogeneration plants have even higher utilization factors.
  • 19. 19 A cogeneration plant with adjustable loads. At times of high demand for process heat, all the steam is routed to the process-heating units and none to the condenser (m7= 0). The waste heat is zero in this mode. If this is not sufficient, some steam leaving the boiler is throttled by an expansion or pressure- reducing valve to the extraction pressure P6 and is directed to the process-heating unit. Maximum process heating is realized when all the steam leaving the boiler passes through the PRV (m5= m4). No power is produced in this mode. When there is no demand for process heat, all the steam passes through the turbine and the condenser (m5=m6=0), and the cogeneration plant operates as an ordinary steam power plant.
  • 20. 20 COMBINED GAS–VAPOR POWER CYCLES • The continued quest for higher thermal efficiencies has resulted in rather innovative modifications to conventional power plants. • A popular modification involves a gas power cycle topping a vapor power cycle, which is called the combined gas–vapor cycle, or just the combined cycle. • The combined cycle of greatest interest is the gas-turbine (Brayton) cycle topping a steam-turbine (Rankine) cycle, which has a higher thermal efficiency than either of the cycles executed individually. • It makes engineering sense to take advantage of the very desirable characteristics of the gas-turbine cycle at high temperatures and to use the high- temperature exhaust gases as the energy source for the bottoming cycle such as a steam power cycle. The result is a combined gas–steam cycle. • Recent developments in gas-turbine technology have made the combined gas– steam cycle economically very attractive. • The combined cycle increases the efficiency without increasing the initial cost greatly. Consequently, many new power plants operate on combined cycles, and many more existing steam- or gas-turbine plants are being converted to combined-cycle power plants. • Thermal efficiencies over 50% are reported.
  • 22. 22 Summary • The Carnot vapor cycle • Rankine cycle: The ideal cycle for vapor power cycles  Energy analysis of the ideal Rankine cycle • Deviation of actual vapor power cycles from idealized ones • How can we increase the efficiency of the Rankine cycle?  Lowering the condenser pressure (Lowers Tlow,avg)  Superheating the steam to high temperatures (Increases Thigh,avg)  Increasing the boiler pressure (Increases Thigh,avg) • The ideal reheat Rankine cycle • The ideal regenerative Rankine cycle  Open feedwater heaters  Closed feedwater heaters • Second-law analysis of vapor power cycles • Cogeneration • Combined gas–vapor power cycles