SlideShare a Scribd company logo
Curriculum Vitae
“Aim is not to be biggest but to be acknowledged as the best”
Name : Jabbar Singh Shekhawat
Qualification : B.E (Electronics Instrumentation &Control)
Designation : Control & Instrumentation Manager
Company : Reliance Utility & Power PVT. Ltd. Job Exp. : 5.10 Years
C.T.C :7.00 Lac /Anm. Email id : jabbar.shekhawat@gmail.com
Industry : Thermal power plant
Notice Period : 3 Months
Mo No :7600174639
Objective
Intend to build a career with leading corporate of hi-tech environment with committed & dedicated people, which will
help me to explore myself and realize my potential.
Profile
I am working in thermal power plant from last 5.6 years as a Control & Instrumentation Manager.
Career Abstracts & Education Details
Skills
➢ Knowledge of following D.C.S :-
1. A.B.B(PM866 ,PM 861 ,800XA)
2. Honeywell (C-300,200 & E.P.K.S 311.1) ,
3. Metso (MAX DNA 4F )
 Fine knowledge of open & closed loops with elements used for additional benefits for Auto & Cascade
controls like- feed forward, lead lag compensation & gain adjustment.
 Fine knowledge of process loops like -
1. Auto Combustion for Boiler
2. Furnace draft controls,
3. 3 Elements or 1 Element.
 Implement logic's as per process requirement.
 Done FAT & SAT on ABB D.C.S. for project of thermal power plant 5*500 TPH
EMPLOYER TIME FRAME DURATION Thermal Power Plant
RELIANCE ULTILITY & POWER PVT. LTD FEB 2016-TILL NOW 6 MONTHS 5*500 TPH BOILER CFB(THERMAX) & 4*93.5
MW TG (BHEL)
WARTSILA INDIA Ltd. JUNE-2014-JAN-2016 1.8 YEARS 1*80 MW PF BOILER(BHEL)
THERMAX INDIA Ltd. SEP 2011-JUNE-2014 2.9 YEARS 1*80 MW PF BOILER(BHEL)
MACABER BEEKAY Pvt. Ltd. OCT 2010 –SEP 2011 1 YEAR 6*210MW ASH HANDLING SYSTEM
 Knowledge of F.S.S.S.(Furnace safeguard& supervisory system), B.M.S (Burner management system),
governing console of BHEL Turbine ,A.H.P (ash handling & process control).
Job Profile
My basic work is to troubleshoot & control the process parameters from either field instrumentation or
programing portion of D.C.S.
 DCS & PLC PORTION FOLLOWING ACTIVITIES ARE CARRIED OUT:-
1. Back-up of history ,events, alarms ,database ,HMI displays ,SQL data base ,logic & network database, are taken
Quarterly or when modification is done .
2. Updating the I/O list & wiring diagram after modification at DCS or in field .
3. P.I.D tuning is done for Closed loops at regular intervals for better plant efficiency.
4. Loop testing, logic's modification & integrating hardware of D.C.S for process requirement.
5. Signal ground & Panel ground are checked at regular intervals to avoid leakage current interference.
6. For monitoring DCS healthiness, checklist is filed on daily basis.
7. Creation of Control module, channel assignment, scale assignment or any graphics designing are done when
required.
 FIELD INSTRUMENTATION PORTION FOLLOWING ACTIVITIES ARE CARRIED OUT:-
1. Commissioning of field instruments like control valve, transmitters ,switches ,Thermocouple , R.T.D, Solenoid
valves, Gauges , Motorized Valve limits adjustment etc. Also calibration or installation carried out whenever
required.
2. Spare planning is done as per 10% demand.
3. Logics are checked as per logic sheets, also modified as per process & field requirement
4. Safety instructions & standard maintenance procedures for any activity are followed in proper manner. .
5. Trouble shout’s critical cases in online & offline condition.
Achievements
1. Implementation of d/dt logic to avoid malfunction by temperature measuring devices.
2. Maintenance mode for ID & FD Fan online maintenance, without stopping the whole series.
I hereby declare that above-mentioned details are true and best on behalf of my knowledge.
Date :-- Signature( )
JABBAR SINGH SHEKHAWAT

More Related Content

DOC
KAMLESH KUMAR YADAV
DOCX
Sharma Resume
DOCX
Power plant desk operation engineer(Boiler, turbine, HVAC)
DOC
Wasif Tahir 1
DOC
reseume ccr
PDF
RESUME october 2016 F
PDF
Bilal.cv
DOC
cv of Shohid
KAMLESH KUMAR YADAV
Sharma Resume
Power plant desk operation engineer(Boiler, turbine, HVAC)
Wasif Tahir 1
reseume ccr
RESUME october 2016 F
Bilal.cv
cv of Shohid

What's hot (19)

DOCX
rakesh resume_10.03.2016
DOC
MM GUANZON, CV- MAINTENANCE ENGINEER
PDF
Waste to Energy
DOCX
Project Arsenal
PPT
Ac installation justin tx
DOCX
Resume' 2015
DOCX
ALBARICK POWER PLANT NEW CV
RTF
Alhalak Subhi
DOCX
TERRY A EVANS RESUME Inspection 07-22-2016
DOC
comising
DOC
V O Keeffe
DOC
ugandhar CompEx resume
DOCX
William Resume
PDF
Resume - Chris Massey
DOC
new resume 2016c
DOCX
DARIUS RODRIGUEZ ANGELES 2016 resume
DOC
rajesh remsu
PDF
DOCX
UPDATED CV-1
rakesh resume_10.03.2016
MM GUANZON, CV- MAINTENANCE ENGINEER
Waste to Energy
Project Arsenal
Ac installation justin tx
Resume' 2015
ALBARICK POWER PLANT NEW CV
Alhalak Subhi
TERRY A EVANS RESUME Inspection 07-22-2016
comising
V O Keeffe
ugandhar CompEx resume
William Resume
Resume - Chris Massey
new resume 2016c
DARIUS RODRIGUEZ ANGELES 2016 resume
rajesh remsu
UPDATED CV-1
Ad

Similar to CV 2016 INSTRIMENTATION (20)

DOC
DOCX
VEERA JANGA CV
DOCX
ROHIT JOSHI JI
DOCX
Cv tapan kumar prusty updated
DOC
RESUME
DOC
prakash_final
DOCX
Ashutosh CV
DOC
Palanikumar Resume
DOC
TPCIL VIVEK
DOCX
Hari Shankar
DOCX
CV bharat new
DOC
comising
DOC
Amit Resume
DOC
CV_HARDIK_CHAUHAN
DOC
Cv hardik chauhan
DOC
Nitesh 1 pager CV Green
PDF
Chandrasekar G resume - Instrument Engineer new
DOC
CV Nagashiva
PDF
social profile _sachin soni_220715
VEERA JANGA CV
ROHIT JOSHI JI
Cv tapan kumar prusty updated
RESUME
prakash_final
Ashutosh CV
Palanikumar Resume
TPCIL VIVEK
Hari Shankar
CV bharat new
comising
Amit Resume
CV_HARDIK_CHAUHAN
Cv hardik chauhan
Nitesh 1 pager CV Green
Chandrasekar G resume - Instrument Engineer new
CV Nagashiva
social profile _sachin soni_220715
Ad

CV 2016 INSTRIMENTATION

  • 1. Curriculum Vitae “Aim is not to be biggest but to be acknowledged as the best” Name : Jabbar Singh Shekhawat Qualification : B.E (Electronics Instrumentation &Control) Designation : Control & Instrumentation Manager Company : Reliance Utility & Power PVT. Ltd. Job Exp. : 5.10 Years C.T.C :7.00 Lac /Anm. Email id : jabbar.shekhawat@gmail.com Industry : Thermal power plant Notice Period : 3 Months Mo No :7600174639 Objective Intend to build a career with leading corporate of hi-tech environment with committed & dedicated people, which will help me to explore myself and realize my potential. Profile I am working in thermal power plant from last 5.6 years as a Control & Instrumentation Manager. Career Abstracts & Education Details Skills ➢ Knowledge of following D.C.S :- 1. A.B.B(PM866 ,PM 861 ,800XA) 2. Honeywell (C-300,200 & E.P.K.S 311.1) , 3. Metso (MAX DNA 4F )  Fine knowledge of open & closed loops with elements used for additional benefits for Auto & Cascade controls like- feed forward, lead lag compensation & gain adjustment.  Fine knowledge of process loops like - 1. Auto Combustion for Boiler 2. Furnace draft controls, 3. 3 Elements or 1 Element.  Implement logic's as per process requirement.  Done FAT & SAT on ABB D.C.S. for project of thermal power plant 5*500 TPH EMPLOYER TIME FRAME DURATION Thermal Power Plant RELIANCE ULTILITY & POWER PVT. LTD FEB 2016-TILL NOW 6 MONTHS 5*500 TPH BOILER CFB(THERMAX) & 4*93.5 MW TG (BHEL) WARTSILA INDIA Ltd. JUNE-2014-JAN-2016 1.8 YEARS 1*80 MW PF BOILER(BHEL) THERMAX INDIA Ltd. SEP 2011-JUNE-2014 2.9 YEARS 1*80 MW PF BOILER(BHEL) MACABER BEEKAY Pvt. Ltd. OCT 2010 –SEP 2011 1 YEAR 6*210MW ASH HANDLING SYSTEM
  • 2.  Knowledge of F.S.S.S.(Furnace safeguard& supervisory system), B.M.S (Burner management system), governing console of BHEL Turbine ,A.H.P (ash handling & process control). Job Profile My basic work is to troubleshoot & control the process parameters from either field instrumentation or programing portion of D.C.S.  DCS & PLC PORTION FOLLOWING ACTIVITIES ARE CARRIED OUT:- 1. Back-up of history ,events, alarms ,database ,HMI displays ,SQL data base ,logic & network database, are taken Quarterly or when modification is done . 2. Updating the I/O list & wiring diagram after modification at DCS or in field . 3. P.I.D tuning is done for Closed loops at regular intervals for better plant efficiency. 4. Loop testing, logic's modification & integrating hardware of D.C.S for process requirement. 5. Signal ground & Panel ground are checked at regular intervals to avoid leakage current interference. 6. For monitoring DCS healthiness, checklist is filed on daily basis. 7. Creation of Control module, channel assignment, scale assignment or any graphics designing are done when required.  FIELD INSTRUMENTATION PORTION FOLLOWING ACTIVITIES ARE CARRIED OUT:- 1. Commissioning of field instruments like control valve, transmitters ,switches ,Thermocouple , R.T.D, Solenoid valves, Gauges , Motorized Valve limits adjustment etc. Also calibration or installation carried out whenever required. 2. Spare planning is done as per 10% demand. 3. Logics are checked as per logic sheets, also modified as per process & field requirement 4. Safety instructions & standard maintenance procedures for any activity are followed in proper manner. . 5. Trouble shout’s critical cases in online & offline condition. Achievements 1. Implementation of d/dt logic to avoid malfunction by temperature measuring devices. 2. Maintenance mode for ID & FD Fan online maintenance, without stopping the whole series. I hereby declare that above-mentioned details are true and best on behalf of my knowledge. Date :-- Signature( )