Chapter 13
Design of a Domestic Defluoridizing Unit
Shaheda Parveen, Venkata Nadh Ratnakaram , Sireesha Malladi
and K. Kiram Kumar
Abstract While trace amounts of fluorine are essential for life, its excessive intake
leads to a disease known as fluorosis. It is a predominant ailment in majority of the
countries inclusive of India. It is caused also by drinking fluoride containing water.
Retention of fluorine in bones and teeth occurs through F−
–(OH−
) exchange on their
inorganic component known as hydroxylapatite. Endeavour of the present study is to
design a column using activated alumina as an adsorbent for continuous defluorida-
tion of water for domestic purpose. As a part of it, operational defluoridation capacity
of alumina was determined by variation of different factors (amount of alumina, time,
temperature, added salts). A family of four members was taken as a model. The ini-
tial and final fluoride concentrations were taken as 2.0 and 0.7 ppm, respectively.
Dimension of the unit (adsorbent bed diameter and height) was determined.
Keywords Design · Domestic defluoridizing unit · Fluorosis
13.1 Introduction
Human beings and animals suffer from fluorosis due to extended acquaintance with
fluoride containing water, air or food. India stands in the top listed countries which
are challenged with fluorosis problem in view of obligatory consumption of water
having high quantities of fluoride (1–48 ppm) [1]. In India, Andhra Pradesh State is
one among the many affected belts by endemic fluoride [2]. As per Indian standards,
S. Parveen
Department of Chemistry, Madurai Kamaraj University, Madurai 625021, India
V. N. Ratnakaram (B)
GITAM University, Bengaluru Campus, Bengaluru 561203, Karnataka, India
e-mail: doctornadh@yahoo.co.in
S. Malladi
Department of Science and Humanities, Division of Chemistry, VFSTR, Vadlamudi 522213, India
K. Kiram Kumar
Department of Chemistry, KBN College, Vijayawada 520001, India
© Springer Nature Singapore Pte Ltd. 2020
B. Subramanian et al. (eds.), Emerging Technologies for Agriculture
and Environment, Lecture Notes on Multidisciplinary Industrial Engineering,
https://doi.org/10.1007/978-981-13-7968-0_13
173
174 S. Parveen et al.
acceptable limit of fluoride concentration in drinking water is 1.0 mg L−1
, whereas
its permissible limit is 1.5 mg L−1
[3]. Though higher concentrations of fluoride
cause fluorosis, its lower concentration is proved to be useful. Fluoride plays a vital
role in mineralization of some of the hard tissues [4]. Fluoride is added to community
water in some of the countries including USA as a part of health measure in order to
inhibit dental decay [5]. Fluoride concentration in mg L−1
and associated potential
health effects can be given as: <0.5 (dental carries are prevented minimally), 0.5–1.5
(favourabletopreventthedentalcarries),1.5–4(causesdentalfluorosis),4–10(dental
and skeletal fluorosis) and >10 (crippling fluorosis) [6]. Dental fluorosis can be easily
recognized by symptom—mottling of teeth [7].
About 300 mg of fluorine per kg is its abundance in earth crust [8]. Fluorspar,
cryolite and fluorapatite are some of the fluorine-containing minerals which undergo
weathering process leading to its accumulation in soil and hence in water [9]. In
some of the areas like Ethiopian Rift Valley, high fluoride concentration in drinking
water can be related to volcanic deposits being the natural fluoride sources [10]. High
concentrations of fluoride were noticed in thermal waters having basic pH [11]. Dif-
ferent anthropogenic and industrial activities release fluoride into the environment.
Some of them are manufacturing units of fertilizers, pesticides, glass, electronics and
aluminium [12].
Water supply in rural areas of a maximum number of countries is suffering from
poor quality and quantities. Ion exchange, reverse osmosis (RO) and electro-dialysis
are the popular methods in developed countries, but they require high capital cost,
maintenance and technical backing [13]. Problems in disposal of large volumes of
sludge and high operational cost are opposing the adopting the well-known Nal-
gonda technique. The other defluoridation methods (adsorption, nanofiltration, ion
exchange, solar distillation and reverse osmosis) have their own advantages and dis-
advantages. Hence, adoption of the method must be based on local needs. Compared
to other defluoridation methods, adsorption method is more preferable in view of
easy operation, lack of sludge formation, low capital cost and easy replacement
of exhausted bed [14]. However, the well-known adsorbent—animal charcoal—is
facing resistance due to the prevailing social customs. Though a large number of
cost-effective biosorbents are reported for defluoridization in the literature, their
technical usage in rural areas is not possible in immediate course of time. In spite
of availability of a wide variety of adsorbents, AA is the best choice in developing
countries. Hence, activated alumina is selected as an adsorbent in the present study.
The rural community in Chebrolu mandal has been distressed by fluorosis (both
dental and skeletal) due to consumption of water having more fluoride concentration
than the permissible limits. Chebrolu mandal of Guntur District, Andhra Pradesh,
was taken as one unit for fluoride estimation in groundwaters. Apart from fluoride
estimation, chloride and total hardness were also estimated. Based on this compila-
tion, it is found that in some villages like Gudavarru and Veera Nayakuni Palem, the
fluoride concentration is more than the limit 1.5 ppm given by WHO. An effort has
been made to design an economically practicable defluoridation unit with continuous
flow, which can be used in rural areas.
13 Design of a Domestic Defluoridizing Unit 175
13.2 Experimental
13.2.1 Selection of Activated Alumina
The literature survey shows that cost of the treated water by activated alumina is less
compared to other defluoridizing agents [15]. Compared to adsorption of CaCO3
(0.03 mg F−
per g), activated alumina is proved to be better adsorbent (0.57 mg F−
per g) [15, 16]. A number of researchers are worked on defluoridation of water using
AA since the suggestion of Boruff [17]. Bulusu and Nawlakhe [18] established that its
sorption capacity is variable and depends on water quality parameters, ionic environ-
ment and regeneration procedures. Simultaneous occurrence of different reactions at
AA surface (like ion exchange and hydrolysis) causes a variation in surface electro-
kinetic properties [19]. It helps to increase the sorption of fluoride ions due to a
decline of negative charges at its surface [18]. Hence, activated alumina was selected
as an adsorbent for defluoridation of water. Commercially available technical grade
activated alumina granules supplied by Sethiya Solvents & Chemicals, Tamil Nadu,
were used.
13.2.2 Batch Adsorption Studies
In each system, 300 mL of water (containing 2 ppm of fluoride, 113 ppm of chloride,
420 ppm of total hardness) is taken in a 500-mL polyethylene container and main-
tained at 31 °C. The solution is stirred at 240 rpm mechanically for definite period
after the addition of desired amounts of adsorbent. The suspension is filtered through
a sintered crucible (G4). The filtrate is tested for fluoride by SPADNS method, chlo-
ride by silver nitrate method and hardness by EDTA method [20]. The final fluoride
concentrations were measured by Zr-SPADNS method [21]. The fluoride concen-
tration in the sample after defluoridation is calculated from absorbance value of its
coloured solution and standard curve. The same procedure is adopted for all the
experiments carried out by varying amount of adsorbent, contact time, temperature
and added salts. The percentage removal of fluoride/chloride/total hardness of water
is calculated from C0 (initial concentration in solution) and Ce (final concentration
in solution after adsorption).
176 S. Parveen et al.
13.3 Results and Discussion
13.3.1 Batch Mode Defluoridation of Water by Activated
Alumina
It is very well-known fact that activated alumina acts as an efficient defluoridizing
agent. Therefore, it is thought worthwhile to know the effect of various factors affect-
ing the defluoridation capacity of activated alumina, before designing the column for
continuous defluoridation of water using activated alumina as an adsorbent.
It is observed that with an increase in the amount of activated alumina, an increase
in the % removal of fluoride is observed (Fig. 13.1a). It can be explained based on
the increased active sites availability causing an improvement of active surface area,
especially at higher adsorbent doses [22]. Afterwards, equilibrium is attained beyond
certain dose. The effect of the agitation time on the removal of fluoride ion is shown in
Fig. 13.1b, whichclearlyindicates that theremoval of fluorideis fast duringearlytime
but turns out to be slow and almost decays with a further rise in the interaction period
beyond 10 min. It hints that the fluoride removal rate is greater in the early phase
because of availability of sufficient adsorbent surface area. A decrease in adsorption
takes place with further increase in contact interaction period because of a decline in
the accessibility to the active sites. Percentage of fluoride ion adsorption increased
with an increase in contact time and the observed can be endorsed to the point that
higher duration makes acquainted the fluoride ion to make adsorb on adsorbent [23].
The maximum adsorption percentage was recorded at 10 min with all adsorbents,
and then onwards, sluggishness was observed. Per cent of defluoridation increased
up to 31°C and then decreased (Fig. 13.2b). It shows that chemisorption is activated
with an increase in temperature. Further confirmation of governing of chemisorption
in the fluoride adsorption on activated alumina is evident as it obeys Langmuir’s
adsorption isotherm [24].
To study the effect of the existence of anions (like chloride) and cations (like cal-
cium) on the defluoridation capacity of water, sodium chloride and calcium chloride
were added. There is no effect of added anions like chloride on the defluoridation of
Fig. 13.1 Effect of a adsorbent dose and b time on % removal of fluoride
13 Design of a Domestic Defluoridizing Unit 177
Fig. 13.2 Effect of a salt type and amount, and b temperature on % removal of fluoride
water as there is no change in the defluoridization capacity with a rise in [chloride
ion]. But, the concentration of fluoride decreased progressively with an increase in
the concentration of the added calcium chloride (Fig. 13.2a). The observed decrease
in fluoride concentration can be attributed to the added calcium ion because there is
no effect of chloride ion on defluoridation. Moreover, it is an established fact that
the fluoride can be removed as calcium fluoride by the calcium ions. In spite of high
affinity towards fluoride by adsorbents containing Al, Zr, Mg and Ca, the presence
of some anions (nitrate, sulphate, bicarbonate and phosphate) decreases their affinity
[25–27]. Adsorption of chloride and nitrate ions on activated alumina is negligible,
whereas sulphate and bicarbonate ions adsorb fairly well. Further, an increase in
bicarbonate ions decreases the adsorption of fluoride on activated alumina due to its
competitive adsorption [15]. As many other anions are present in the groundwater
taken in the present case, the efficiency of fluoride ion adsorption decreases further.
Inviewofpracticalconditions,throughoutthepresentstudy,defluoridationstudies
were carried out at neutral pH. However, defluoridation capacity of AA was reported
as 3, 5.6 and 20 mg g−1
for alkaline, neutral and acidic water, respectively [24]. Davis
and Leckie [28] reported that fluoride sorption capacity decreases with an increase in
pH due to a decline in the establishment of ligand-like complexes. It is a known fact
that defluoridation by adsorption is interfered by hydroxide ions. Defluoridation by
activated alumina can be explained by Stern model of double layer. Charge potential
on alumina is zero when pH is 9. As hydrogen ion is the potential-determining ion
for the surface charge of AA, it is positively charged when [H+
] is greater (pH <
9). Hence, negatively charged fluoride ion adsorbs on oppositely charged AA. In
addition, adsorption process is also governed by “specificity factor” and adsorption
order: F−
OH−
HCO3
−
≫ Cl−
= SO4
2−
[24]. Therefore, defluoridation
capacity of AA decreases with an increase in [HCO3
−
].
178 S. Parveen et al.
13.3.2 Determination of Operational Defluoridation Capacity
of Alumina
50 g of activated alumina is added to 1 l of water containing 2 ppm fluoride, 113 ppm
chloride and 420 ppm of total hardness and allowed to be at equilibrium for 24 h and
then filtered. The amount of removed fluoride is estimated colorimetrically based on
the concentration of fluoride in the water before and after adsorption. The process is
repeated with the same alumina with the addition of fresh samples of water added at
the same amounts fluoride, chloride and total hardness. This process is repeated till
there is no defluoridation by the alumina. The total defluoridation capacity is found
to be 57 mg fluoride/50 g of alumina. Therefore, operational defluoridation capacity
of the alumina is 1.14 mg fluoride g of alumina. The literature survey shows that
adsorption capacities (mg g−1
) of AA (OA-25 grade), AA (AD101-F grade), acidic
alumina, modified AA and third aluminium hydrate (TAH) are compiled as 1.78,
0.42, 8.4, 0.76 and 25.8, respectively [29]. Probably, there exists a high variance in
“degree of activation” in variety of alumina products. Another justification may be a
difference in pH in addition to the brand of the product. Most of the previous research
works involve the usage of distilled water for fluoride ion solution preparation and
high grade alumina with high adsorption capacity. But in the present study, it is
based on water having different salts and technical grade alumina. Therefore, the
operational capacity—1.14 mg/g—is considered while designing the column for
defluoridation.
13.3.3 Design of Continuous Defluoridizing Unit
Compared to other defluoridation methods, packed bed adsorption method is more
preferred. Some of its advantages are easier operation, reasonable capital and oper-
ational costs, no sludge formation and easy replacement of bed [30]. Batch method
faces three main problems, i.e. (1) drying of filter bed and hence shortening of life-
time of filter for intermittent usage, (2) incomplete utilization of adsorbent and (3)
limited release of defluoridate water at once. Hence, a continuous defluoridizing unit
is designed in the present study. Combined filter contains two filter processes in
the same structure to remove fluoride and microbes by using adsorbent and silver
nitrate, respectively. However, in view of disadvantages like higher cost, maintenance
requirement, low susceptibility to higher turbidity, etc., the concept of combined fil-
ters was not considered.
An attempt has been made to design the column using activated alumina as an
adsorbent for defluoridation of water continuously for domestic purpose. A family
of four members was taken as a model. The initial and final fluoride concentrations
are taken as 2.0 and 0.7 ppm, respectively.
Daily personal water demand = D = 3 l/consumer/day
Number of users = N = 4
13 Design of a Domestic Defluoridizing Unit 179
Operation period = OP = 2 ½ months = 75 days
Operational sorption capacity = C = 1.14 g/kg
Bulk density of alumina = ρ = 1.12 kg/l
Raw water fluoride concentration = Fi = 2.0 mg/l
Mean fluoride concentration in treated water = 0.7 mg/l
Volume ratio supernatant water/medium = VRSW/M = 0.2
Daily water treatment = Q = D × N = 12 l/day
Overall quantity of treated water in a filter period = VT = Q × OP = 900 l
Overall quantity of removed fluoride in a filter period = FT = VT ×(Fi −Ft)
1000
= 1.17 g
Amount of Al2O3 required for renewal = M = FT/C = 1.03 kg
Volume of Al2O3 in filter = VM = M/ρ = 0.916 l ∼= 0.95 l
Treated no. of bed volumes during filter period = BV = VT
VM
= 982
Supernatant water volume capacity = VSW = VRSW/M × VM = 0.183 l ∼= 0.2 l
Total volume of filter = VF = Vm + VSW = 0.95 + 0.2 = 1.15 l.
13.3.4 Corresponding Dimensions
Karthikeyan et al. [24] studied the rate of water flow in a column filled with activated
alumina. According to them, variation in column height and particle size causes a
substantial alteration in water flow rate. Particle size increase caused a rise in pore
volume leading to an enhancement of flow rate. Bed height increase results in an
enhancement of offered resistance which leads to a decline in flow rate. In view of
these two reasons, selection of bed height and particle size is the important parameter
to be considered while designing a defluoridation unit. Important issue to be noted
is that minimum contact period is required between adsorbent and fluoride ion to be
removed. At the same time, very lower flow rate design will not be accepted by end-
users. Taking into consideration the equal weightage of flow rate and defluoridation
capacity, it is decided to choose the intermediate size of the particle in the range
140–180 mm because both factors are optimal in the chosen range. Based on it,
fixation of column height was done. Moreover, it is always advisable to select the ratio
of column diameter to particle diameter as more than 20 to decrease the channelling
chances [31, 32]. Several trails were made with different dimensions, and it is found
that the optimum diameter as 7 cm for the decided quantity of alumina.
Filter diameter (selected) = Φ = 7 cm
Total height of the filter = HF = VF/[π × (Φ/2)2
] = 29.897 cm ∼= 30 cm.
13.3.5 Defluoridation Studies on the Designed Unit
PVC pipe having an internal diameter of 7 cm was used for this study. The column
was connected to a feed tank with inlet control valve. Activated alumina bed was
fixed, and proper distribution in it was ensured by packing it between two circular
180 S. Parveen et al.
Fig. 13.3 Design of the
proposed house hold
defluoridation unit
perforated PVC sheets. Plug pairs encompass these sheets which function as filter-
ing medium to remove any dust/dirt from inlet and support to the bed, respectively
(Fig. 13.3). Random packing of adsorbent is ensured by initial filling of the column
with deionized water followed by activated alumina, whereas the reverse filling order
may result in a decline of adsorbent efficiency due to the development of air gaps
which leads to further channelling phenomenon. A closely packed adsorbent bed
was ensured by soaking with distilled water and leaving for overnight. It is a known
fact that activated alumina on hydration changes from the mineral form boehmite
(AlOOH) to gibbsite (γ-Al(OH)3) [33]. Further, it was also established that fluoride
better uptake by it happens due to a change in surface morphology, which is done
by soaking it for one day [34]. Hence, the above overnight soaking of bed with dis-
tilled water also helps to improve defluoridation. Process was carried out at room
temperature. Column kept filled with feed water even during resting period. Practical
aspects in the usage of AA for defluoridation of water were studied by regulating the
flow rate in order to maintain minimum 5 min contact time. Input and output were
collected at regular intervals of time in order to analyse the fluoride concentration.
The residual amount of fluorine in outlet water was found to be within permissi-
ble limits. However, the three key issues involved in realization of any household
defluoridation units are (1) motivation, (2) appropriate and cheap technique and (3)
technical support including training on efficient regeneration to one of the villagers
to continue without any support from external agencies [35]. Similar to defluorida-
tion studies, decontamination units may be designed for the removal of heavy metals
using agricultural waste as adsorbents [35–39].
13 Design of a Domestic Defluoridizing Unit 181
13.3.6 Regeneration of Bed
A fourfold higher regeneration was observed with 0.1 N sodium hydroxide solution
compared to 0.1 N hydrochloric acid solution. High negative charges are created on
the surface of AA during elution of fluoride using sodium hydroxide. Hence, the
already adsorbed F−
experience repulsion from the surface leading to their diffusion
into solution [24]. For regeneration, the exhausted AA was shifted into a bag made up
of nylon mesh and immersed in alkali solution for overnight with intermittent stirring.
A marginal decrease in adsorption capacity was observed even after 25 regeneration
cycles.
13.4 Conclusions
Lower values of operational defluoridation capacity of alumina can be explained
based on the presence of competitive ions in the water to be treated. A continuous
defluoridation unit was designed for domestic purpose using activated alumina as an
adsorbent. The residual amount of fluorine in outlet water from the unit was found
to be within permissible limits. Sodium hydroxide solution (0.1 N) was found to be
the best regenerating agent for the exhausted bed.
References
1. Ramesh,H.S.,Kamaraju,M.:Continuousflowdefluoridationunitforruralwatersupplyscheme
of fluoride prone areas. In: World Environmental and Water Resource Congress 2006: Exam-
ining the Confluence of Environmental and Water Concerns, pp. 1–10 (2006)
2. Sahu, P., Kisku, G.C., Singh, P.K., Kumar, V., Kumar, P., Shukla, N.: Multivariate statistical
interpretation on seasonal variations of fluoride-contaminated groundwater quality of Lalganj
Tehsil, Raebareli District (UP). India. Environ. Earth Sci 77(13), 484 (2018). https://doi.org/
10.1007/s1266
3. Bureau of Indian Standards: Indian Standard: Drinking Water—Specification. Bureau of Indian
Standards, New Delhi (2012)
4. Heikens, A., Sumarti, S., Van Bergen, M., Widianarko, B., Fokkert, L., Van Leeuwen, K.,
Seinen, W.: The impact of the hyperacid Ijen Crater Lake: risks of excess fluoride to human
health. Sci. Total Environ. 346(1–3), 56–69 (2005). https://doi.org/10.1016/j.scitotenv.2004.
12.007
5. American Dental Association (ADA).: Fluoridation Facts. ADA Statement Commemorating
the 60th Anniversary of Community Water Fluoridation, 211 East Chicago Avenue Chicago,
Illinois 60611-2678 (2005)
6. Dissanayake, C.B.: The fluoride problem in the groundwater of Srilanka—environmental
management and health. Int. J. Environ. Stud 19, 195–203 (1991). https://doi.org/10.1080/
00207239108710658
7. Nie, Y., Hu, C., Kong, C.: Enhanced fluoride adsorption using Al (III) modified calcium hydrox-
yapatite. J. Hazard. Mater. 233, 194–199 (2012). https://doi.org/10.1016/j.jhazmat.2012.07.
020
182 S. Parveen et al.
8. Tebutt, T.: Relationship Between Natural Water Quality and Health. United Nations Educa-
tional, Scientific and Cultural Organization, Paris (1983)
9. Murray, J.J.: Appropriate Use of Fluorides for Human Health. World Health Organization,
Geneva (1986)
10. Tekle-Haimanot, R., Melaku, Z., Kloos, H., Reimann, C., Fantaye, W., Zerihun, L., Bjorvatn,
K.: The geographic distribution of fluoride in surface and groundwater in Ethiopia with an
emphasis on the Rift Valley. Sci. Total Environ. 367(1), 182–190 (2006). https://doi.org/10.
1016/j.scitotenv.2005.11.003
11. Fawell, J., Bailey, K., Chilton, J., Dahi, E., Magara, Y.: Fluoride in drinking-water. IWA pub-
lishing World Health Organization and IWA Publishing, London (2006)
12. Pietrelli, L.: Fluoride wastewater treatment by adsorption onto metallurgical grade alumina.
Anal. Chim. 95, 303–312 (2005)
13. Maheshwari, R.C.: Fluoride in drinking water and its removal. J. Hazard. Mater. 137(1),
456–463 (2006). https://doi.org/10.1016/j.jhazmat.2006.02.024
14. Mehari, B.B., Mayabi, A.O., Kakoi, B.K.: Development of household defluoridation unit based
on crushed burnt clay pot as sorbent medium: a case of Keren Community, Eritrea. Environ.
Nat. Resour. Res. 4(3), 67 (2014)
15. Samrat, M.V., Rao, K.K., SenGupta, A.K., Riotte, J., Mudakavi, J.R.: Defluoridation of reject
water from a reverse osmosis unit and synthetic water using adsorption. J. Water Process Eng.
23, 327–337 (2018). https://doi.org/10.1016/j.jwpe.2017.07.015
16. Babu, C.A., Sujish, D., Murugappa, M.S., Mohanakrishnan, G., Kalyanasundaram, P., Raj,
B.: A comprehensive treatment method for defluoridation of drinking water. Indian J. Chem.
Technol. 18, 314–318 (2011)
17. Boruff, C.S.: Removal of fluorides from drinking waters. Ind. Eng. Chem. 26(1), 69–71 (1934).
https://doi.org/10.1021/ie50289a016
18. Bulusu, K.R., Nawlakhe, W.G.: Defluoridation of water with activated alumina: batch opera-
tions. Indian J. Environ. Health 30(3), 262–299 (1988)
19. Benjamin, M.M., Leckie, J.O.: Conceptual model for metal-ligand-surface interactions dur-
ing adsorption. Environ. Sci. Technol. 15(9), 1050–1057 (1981). https://doi.org/10.1021/
es00091a003
20. American Public Health Association, American Water Works Association.: Standard Methods
for the Examination of Water and Wastewater. American public health association (1989).
21. Bellack, E., Schouboe, P.J.: Rapid photometric determination of fluoride in water. Use
of sodium 2-(p-sulfophenylazo)-1, 8-dihydroxynaphthalene-3, 6-disulfonate-zirconium lake.
Anal. Chem. 30(12):2032–2034 (1958). https://doi.org/10.1021/ac60144a050
22. Gupta, V.K., Sharma, S.: Removal of cadmium and zinc from aqueous solutions using red mud.
Environ. Sci. Technol. 36(16), 3612–3617 (2002). https://doi.org/10.1021/es020010v
23. Bhattacharya, A.K., Mandal, S.N., Das, S.K.: Adsorption of Zn (II) from aqueous solution by
using different adsorbents. Chem. Eng. J. 123(1–2), 43–51 (2006). https://doi.org/10.1016/j.
cej.2006.06.012
24. Karthikeyan, G., Meenakshi, S., Apparel, B.V.: Defluoridation properties of activated alumina.
In: Dahi, E., Nielsen, J.M. (eds.) 2nd International Workshop on Fluorosis Prevention and
Defluoridation of Water, pp. 19–25 (1997)
25. Loganathan, P., Vigneswaran, S., Kandasamy, J., Naidu, R.: Defluoridation of drinking water
using adsorption processes. J. Hazard. Mater. 248, 1–9 (2013). https://doi.org/10.1016/j.
jhazmat.2012.12.043
26. Mondal, P., George, S.: A review on adsorbents used for defluoridation of drinking water. Rev.
Environ. Sci. Biotechnol. 14(2), 195–210 (2015). https://doi.org/10.1007/s11157-014-9356-0
27. Velazquez-Jimenez, L.H., Vences-Alvarez, E., Flores-Arciniega, J.L., Flores-Zuniga, H.,
Rangel-Mendez, J.R.: Water defluoridation with special emphasis on adsorbents-containing
metal oxides and/or hydroxides: a review. Sep. Purif. Technol. 150, 292–307 (2015). https://
doi.org/10.1016/j.seppur.2015.07.006
28. Davis, J.A., Leckie, J.O.: Surface ionization and complexation at the oxide/water interface.
3. Adsorption of anions. J. Colloid Interface Sci. 74(1):32–43 (1980). https://doi.org/10.1016/
0021-9797(80)90168-x
13 Design of a Domestic Defluoridizing Unit 183
29. Mulugeta, E., Zewge, F., Chandravanshi, B.S.: Development of a household water defluorida-
tion process using aluminium hydroxide based adsorbent. Water Environ. Res. 87(6), 524–532
(2015). https://doi.org/10.2175/106143014X13975035525627
30. Eyobel, M.D.: Removal of fluoride from water using granular aluminium hydroxide: adsorption
in a fixed bed column. M.Sc. Thesis, Environmental Science Program, Addis Ababa University,
Ethiopia (2006)
31. LeVan, M.D., Vermeulen, T.: Channeling and bed-diameter effects in fixed-bed adsorber per-
formance. AIChE Symp 80(233), 34–43 (1984)
32. Zhao, D., SenGupta, A.K.: Ligand separation with a copper (II)-loaded polymeric ligand
exchanger. Ind. Eng. Chem. Res. 39(2), 455–462 (2000). https://doi.org/10.1021/ie990740k
33. Dyer, C., Hendra, P.J., Forsling, W., Ranheimer, M.: Surface hydration of aqueous γ-Al2O3
studied by Fourier transform Raman and infrared spectroscopy—I. Initial results. Spec-
trochim. Acta Part A: Mol. Spectrosc. 49(5–6), 691–705 (1993). https://doi.org/10.1016/0584-
8539(93)80092-o
34. Shreyas, L., Kanwar, L., Rao, K.K.: Chemical engineering and the mitigation of fluorosis.
Indian Chem. Eng. 55(1), 38–49 (2013). https://doi.org/10.1080/00194506.2013.785116
35. Bregnhoj, H.: Critical sustainability parameters in defluoridation of drinking water. In: Dahi, E.,
Nielsen, J.M. (eds.) Proceeding of 2nd International Workshop on Fluorosis and Defluoridation
of Water. International Society of Fluoride Research (1997)
36. Mokkapati, R.P., Mokkapati, J.M., Ratnakaram, V.N.: Chemical oxygen demand reduction
from coffee processing waste water—a comparative study on usage of biosorbents prepared
from agricultural wastes. Glob. Nest. J. 17, 291–300 (2015)
37. Mokkapati, R.P., Mokkapati, J.M., Ratnakaram, V.N.: Kinetic, thermodynamic and equilibrium
studies on removal of hexavalent chromium from aqueous solutions using agro-waste bioma-
terials, casuarina equisetifolia L. and sorghum bicolor. Korean J. Chem. Eng. 33, 2374–2383
(2016). https://doi.org/10.1007/s11814-016-0078-6
38. Mokkapati, R.P., Mokkapati, J.M., Ratnakaram, V.N.: Kinetic, isotherm and thermodynamics
investigation on adsorption of divalent copper using agro-waste biomaterials, Musa acuminata,
Casuarina equisetifolia L. and Sorghum bicolor. Polish J. Chem. Tech. 18(2):68–77 (2016).
https://doi.org/10.1515/pjct-2016-0031
39. Mokkapati, R.P., Ratnakaram, V.N., Mokkapati, J.M.: Utilization of agro-waste for removal of
toxic hexavalent chromium: surface interaction and mass transfer studies. Int. J. Environ. Sci.
Technol. 15(4), 875–886 (2018). https://doi.org/10.1007/s13762-017-1443-7

More Related Content

PDF
Removal of fluoride from drinking water by using low cost adsorbent
PDF
Ijmet 10 01_100
PDF
11.distribution and ecotoxicological risk assessment of persistent organic po...
PDF
1.[1 13]distribution and ecotoxicological risk assessment of persistent organ...
PDF
Gjesm150181451593800
PDF
JEAS_2015030615330496
PPTX
DEFLUORIDATION BY BIOADSORBENTS
PDF
H012314047
Removal of fluoride from drinking water by using low cost adsorbent
Ijmet 10 01_100
11.distribution and ecotoxicological risk assessment of persistent organic po...
1.[1 13]distribution and ecotoxicological risk assessment of persistent organ...
Gjesm150181451593800
JEAS_2015030615330496
DEFLUORIDATION BY BIOADSORBENTS
H012314047

What's hot (18)

PDF
JSEHR 1(1)-6
PDF
Reuse of inorganic sludge as a coagulant on colloidal suspension removal in r...
PDF
55 69%20 ahmed
PDF
Ijciet 06 09_002
PDF
Defluorination of Drinking Water
PDF
IRJET - Removal of Fluoride from Groundwater using Low Cost Natural Adsorbent...
PDF
IRJET- Experimental Study of Fluoride Removal from Drinking Water through the...
PDF
Removal of fluoride from synthetic waste water by using “bio adsorbents”
PDF
DWT article modified wheat husk
PDF
Distribution and ecotoxicological risk assessment of persistent organic pollu...
PDF
11.distribution and ecotoxicological risk assessment of persistent organic po...
PDF
Treatment of distilleries and breweries spent wash wastewater
PDF
Treatment of distilleries and breweries spent wash wastewater
PDF
Ab24190203
PDF
IRJET - Effect of Non-Continuous Aeration on Activated Sludge Process
PPTX
Water Fluoridation
PDF
Parametric Studies on Detergent Using Low Cost Sorbent
PDF
Comparative study on performance of coagulants in
JSEHR 1(1)-6
Reuse of inorganic sludge as a coagulant on colloidal suspension removal in r...
55 69%20 ahmed
Ijciet 06 09_002
Defluorination of Drinking Water
IRJET - Removal of Fluoride from Groundwater using Low Cost Natural Adsorbent...
IRJET- Experimental Study of Fluoride Removal from Drinking Water through the...
Removal of fluoride from synthetic waste water by using “bio adsorbents”
DWT article modified wheat husk
Distribution and ecotoxicological risk assessment of persistent organic pollu...
11.distribution and ecotoxicological risk assessment of persistent organic po...
Treatment of distilleries and breweries spent wash wastewater
Treatment of distilleries and breweries spent wash wastewater
Ab24190203
IRJET - Effect of Non-Continuous Aeration on Activated Sludge Process
Water Fluoridation
Parametric Studies on Detergent Using Low Cost Sorbent
Comparative study on performance of coagulants in
Ad

Similar to Design of a defluoridizing unit (20)

PDF
Removal of fluoride from drinking water by adsorption onto Activated Alumina ...
PPT
deflouridation.ppt
PPTX
Fluoridisation using impregnated Activated Charcoal with Al/Zr
PDF
Ay24334338
PDF
Removal of Fluoride from Drinking Water Using Sawdust
PDF
IRJET- Fluoride Removal using Low Cost Adsorbent – Lime
PDF
Removal of Fluoride From Drinking Water Using Tea Waste as Adsorbent
PPTX
Dissertation phase 2 part 2 Edited copy.pptx
PDF
IRJET- Use of Fly Ash from Soybean Husk and Maize Husk as an Adsorbent for Re...
PPTX
Dissertation phase 2-how to make a dissertation phase 2 ppt2.pptx
PDF
Defluoridation of Ground Water Using Corn Cobs Powder
PDF
Tinospora cordifolia – AS BIOADSORBENT FOR REMOVAL OF FLUORIDE FROM WATER
PPTX
Defluoridation techniques
PPTX
Flouride removal
PPTX
Defluoridation of drinking water using low cost bioadsorbents
PDF
IJCT 14(4) (2007) 350-354
PPTX
L14- Fluoridation & Defluoridation.pptx
PDF
Iaetsd purification of water by natural adsorption process
PDF
Part IV Final Report
PPTX
Nano-adsorbent for fluoride removal from drinking water
Removal of fluoride from drinking water by adsorption onto Activated Alumina ...
deflouridation.ppt
Fluoridisation using impregnated Activated Charcoal with Al/Zr
Ay24334338
Removal of Fluoride from Drinking Water Using Sawdust
IRJET- Fluoride Removal using Low Cost Adsorbent – Lime
Removal of Fluoride From Drinking Water Using Tea Waste as Adsorbent
Dissertation phase 2 part 2 Edited copy.pptx
IRJET- Use of Fly Ash from Soybean Husk and Maize Husk as an Adsorbent for Re...
Dissertation phase 2-how to make a dissertation phase 2 ppt2.pptx
Defluoridation of Ground Water Using Corn Cobs Powder
Tinospora cordifolia – AS BIOADSORBENT FOR REMOVAL OF FLUORIDE FROM WATER
Defluoridation techniques
Flouride removal
Defluoridation of drinking water using low cost bioadsorbents
IJCT 14(4) (2007) 350-354
L14- Fluoridation & Defluoridation.pptx
Iaetsd purification of water by natural adsorption process
Part IV Final Report
Nano-adsorbent for fluoride removal from drinking water
Ad

More from Ratnakaram Venkata Nadh (20)

PDF
Electrochemical study of anatase TiO2 in aqueous sodium-ion electrolytes
PDF
Validated HPLC Method for Assay and Content Uniformity Testing of Roflumilast...
PDF
Substrate Inhibition in Ruthenium(III) Catalyzed Oxidation of Propane-1,3-dio...
PDF
Ruthenium(III) Catalyzed Oxidation of Sugar Alcohols by Dichloroisocyanuric A...
PDF
Shift of Reaction Pathway by Added Chloride Ions in the Oxidation of Aromatic...
PDF
Kinetics of Ruthenium(III) Catalyzed and Uncatalyzed Oxidation of Monoethanol...
PDF
A novel reversed-phase liquid chromatographic method for the simultaneous det...
PDF
Mucoadhesive targeted pulmonary delivery of nanoparticulated dry powder insuf...
PDF
Kinetic, isotherm and thermodynamics investigation on adsorption of divalent ...
PDF
Kinetic, thermodynamic and equilibrium studies on removal of hexavalent chrom...
PDF
Novel coumarin isoxazoline derivatives: Synthesis and study of antibacterial ...
PDF
Ultra performance liquid chromatographic method for simultaneous quantificati...
PDF
Caralluma lasiantha: A review on it’s vital role in Indian Traditional Medicine
PDF
Phytochemical Investigation of Caralluma lasiantha: Isolation of Stigmasterol...
PDF
Phytochemical Screening of Caralluma lasiantha Isolation of C21 Pregnane Steroid
PDF
Supercritical fluid (CO2) chromatography for quantitative determination of se...
PDF
Quality-by-design-based development and validation of a stability-indicating ...
PDF
A convenient new and efficient commercial synthetic route for dasatinib (Spry...
PDF
Utilization of agro-waste for removal of toxic hexavalent chromium: surface i...
PDF
Evaluation of in vitro antibacterial activity of Caralluma lasiantha for scie...
Electrochemical study of anatase TiO2 in aqueous sodium-ion electrolytes
Validated HPLC Method for Assay and Content Uniformity Testing of Roflumilast...
Substrate Inhibition in Ruthenium(III) Catalyzed Oxidation of Propane-1,3-dio...
Ruthenium(III) Catalyzed Oxidation of Sugar Alcohols by Dichloroisocyanuric A...
Shift of Reaction Pathway by Added Chloride Ions in the Oxidation of Aromatic...
Kinetics of Ruthenium(III) Catalyzed and Uncatalyzed Oxidation of Monoethanol...
A novel reversed-phase liquid chromatographic method for the simultaneous det...
Mucoadhesive targeted pulmonary delivery of nanoparticulated dry powder insuf...
Kinetic, isotherm and thermodynamics investigation on adsorption of divalent ...
Kinetic, thermodynamic and equilibrium studies on removal of hexavalent chrom...
Novel coumarin isoxazoline derivatives: Synthesis and study of antibacterial ...
Ultra performance liquid chromatographic method for simultaneous quantificati...
Caralluma lasiantha: A review on it’s vital role in Indian Traditional Medicine
Phytochemical Investigation of Caralluma lasiantha: Isolation of Stigmasterol...
Phytochemical Screening of Caralluma lasiantha Isolation of C21 Pregnane Steroid
Supercritical fluid (CO2) chromatography for quantitative determination of se...
Quality-by-design-based development and validation of a stability-indicating ...
A convenient new and efficient commercial synthetic route for dasatinib (Spry...
Utilization of agro-waste for removal of toxic hexavalent chromium: surface i...
Evaluation of in vitro antibacterial activity of Caralluma lasiantha for scie...

Recently uploaded (20)

PPTX
Environmental pollutants for natural res
PPTX
Afro-Asia Literature.pptxmmmmmmmmmmmmmmm
PDF
Lesson_1_Readings.pdfjjjjjjjjjjjjjjjjjjjjjjjjjjjjj
PDF
The European Green Deal (EU Green Deal)
PPTX
sustainable-development in tech-ppt[1].pptx
PDF
FMM Slides For OSH Management Requirement
DOCX
Double Membrane Roofs for Bio CNG Plants Stores biogas.docx
PDF
1748933543SJA_41_2_826-834 SJA Ihsan ullha.pdf
DOCX
The Ripple Effect: Understanding Extreme Weather Patterns and Geomagnetic Dyn...
PDF
IWRM - City University Presentation 28 may 2018-v3.pdf
PPTX
IMPACTS OF CHEMICAL FERTILIZERS -CHEMPROJ (11).pptx
PPTX
Lecture-05-Audio-lingual. Method & Appro
PPTX
Biodiversity PPT by Gaithanlung Gonmei.pptx
DOCX
Double Membrane Roofs for Biogas Digesters A sealed cover for biogas producti...
PPTX
Climate_Change_Renewable_and_Energy.pptx
PDF
PAKAM TECHNOLOGY LIMTED PITCH DECK pptx.pdf
DOCX
Double Membrane Roofs for Digester Tank Wastewater Treatment Integral to biog...
PPTX
Air_Pollution_Thesis_Presentation (1).pptx
PDF
Harnessing the Earth's Heat with Geothermal Systems Installation
PPTX
Microbial-Pathogens-and-Parasites-Their-Impact-on-Plant-Health.pptx
Environmental pollutants for natural res
Afro-Asia Literature.pptxmmmmmmmmmmmmmmm
Lesson_1_Readings.pdfjjjjjjjjjjjjjjjjjjjjjjjjjjjjj
The European Green Deal (EU Green Deal)
sustainable-development in tech-ppt[1].pptx
FMM Slides For OSH Management Requirement
Double Membrane Roofs for Bio CNG Plants Stores biogas.docx
1748933543SJA_41_2_826-834 SJA Ihsan ullha.pdf
The Ripple Effect: Understanding Extreme Weather Patterns and Geomagnetic Dyn...
IWRM - City University Presentation 28 may 2018-v3.pdf
IMPACTS OF CHEMICAL FERTILIZERS -CHEMPROJ (11).pptx
Lecture-05-Audio-lingual. Method & Appro
Biodiversity PPT by Gaithanlung Gonmei.pptx
Double Membrane Roofs for Biogas Digesters A sealed cover for biogas producti...
Climate_Change_Renewable_and_Energy.pptx
PAKAM TECHNOLOGY LIMTED PITCH DECK pptx.pdf
Double Membrane Roofs for Digester Tank Wastewater Treatment Integral to biog...
Air_Pollution_Thesis_Presentation (1).pptx
Harnessing the Earth's Heat with Geothermal Systems Installation
Microbial-Pathogens-and-Parasites-Their-Impact-on-Plant-Health.pptx

Design of a defluoridizing unit

  • 1. Chapter 13 Design of a Domestic Defluoridizing Unit Shaheda Parveen, Venkata Nadh Ratnakaram , Sireesha Malladi and K. Kiram Kumar Abstract While trace amounts of fluorine are essential for life, its excessive intake leads to a disease known as fluorosis. It is a predominant ailment in majority of the countries inclusive of India. It is caused also by drinking fluoride containing water. Retention of fluorine in bones and teeth occurs through F− –(OH− ) exchange on their inorganic component known as hydroxylapatite. Endeavour of the present study is to design a column using activated alumina as an adsorbent for continuous defluorida- tion of water for domestic purpose. As a part of it, operational defluoridation capacity of alumina was determined by variation of different factors (amount of alumina, time, temperature, added salts). A family of four members was taken as a model. The ini- tial and final fluoride concentrations were taken as 2.0 and 0.7 ppm, respectively. Dimension of the unit (adsorbent bed diameter and height) was determined. Keywords Design · Domestic defluoridizing unit · Fluorosis 13.1 Introduction Human beings and animals suffer from fluorosis due to extended acquaintance with fluoride containing water, air or food. India stands in the top listed countries which are challenged with fluorosis problem in view of obligatory consumption of water having high quantities of fluoride (1–48 ppm) [1]. In India, Andhra Pradesh State is one among the many affected belts by endemic fluoride [2]. As per Indian standards, S. Parveen Department of Chemistry, Madurai Kamaraj University, Madurai 625021, India V. N. Ratnakaram (B) GITAM University, Bengaluru Campus, Bengaluru 561203, Karnataka, India e-mail: doctornadh@yahoo.co.in S. Malladi Department of Science and Humanities, Division of Chemistry, VFSTR, Vadlamudi 522213, India K. Kiram Kumar Department of Chemistry, KBN College, Vijayawada 520001, India © Springer Nature Singapore Pte Ltd. 2020 B. Subramanian et al. (eds.), Emerging Technologies for Agriculture and Environment, Lecture Notes on Multidisciplinary Industrial Engineering, https://doi.org/10.1007/978-981-13-7968-0_13 173
  • 2. 174 S. Parveen et al. acceptable limit of fluoride concentration in drinking water is 1.0 mg L−1 , whereas its permissible limit is 1.5 mg L−1 [3]. Though higher concentrations of fluoride cause fluorosis, its lower concentration is proved to be useful. Fluoride plays a vital role in mineralization of some of the hard tissues [4]. Fluoride is added to community water in some of the countries including USA as a part of health measure in order to inhibit dental decay [5]. Fluoride concentration in mg L−1 and associated potential health effects can be given as: <0.5 (dental carries are prevented minimally), 0.5–1.5 (favourabletopreventthedentalcarries),1.5–4(causesdentalfluorosis),4–10(dental and skeletal fluorosis) and >10 (crippling fluorosis) [6]. Dental fluorosis can be easily recognized by symptom—mottling of teeth [7]. About 300 mg of fluorine per kg is its abundance in earth crust [8]. Fluorspar, cryolite and fluorapatite are some of the fluorine-containing minerals which undergo weathering process leading to its accumulation in soil and hence in water [9]. In some of the areas like Ethiopian Rift Valley, high fluoride concentration in drinking water can be related to volcanic deposits being the natural fluoride sources [10]. High concentrations of fluoride were noticed in thermal waters having basic pH [11]. Dif- ferent anthropogenic and industrial activities release fluoride into the environment. Some of them are manufacturing units of fertilizers, pesticides, glass, electronics and aluminium [12]. Water supply in rural areas of a maximum number of countries is suffering from poor quality and quantities. Ion exchange, reverse osmosis (RO) and electro-dialysis are the popular methods in developed countries, but they require high capital cost, maintenance and technical backing [13]. Problems in disposal of large volumes of sludge and high operational cost are opposing the adopting the well-known Nal- gonda technique. The other defluoridation methods (adsorption, nanofiltration, ion exchange, solar distillation and reverse osmosis) have their own advantages and dis- advantages. Hence, adoption of the method must be based on local needs. Compared to other defluoridation methods, adsorption method is more preferable in view of easy operation, lack of sludge formation, low capital cost and easy replacement of exhausted bed [14]. However, the well-known adsorbent—animal charcoal—is facing resistance due to the prevailing social customs. Though a large number of cost-effective biosorbents are reported for defluoridization in the literature, their technical usage in rural areas is not possible in immediate course of time. In spite of availability of a wide variety of adsorbents, AA is the best choice in developing countries. Hence, activated alumina is selected as an adsorbent in the present study. The rural community in Chebrolu mandal has been distressed by fluorosis (both dental and skeletal) due to consumption of water having more fluoride concentration than the permissible limits. Chebrolu mandal of Guntur District, Andhra Pradesh, was taken as one unit for fluoride estimation in groundwaters. Apart from fluoride estimation, chloride and total hardness were also estimated. Based on this compila- tion, it is found that in some villages like Gudavarru and Veera Nayakuni Palem, the fluoride concentration is more than the limit 1.5 ppm given by WHO. An effort has been made to design an economically practicable defluoridation unit with continuous flow, which can be used in rural areas.
  • 3. 13 Design of a Domestic Defluoridizing Unit 175 13.2 Experimental 13.2.1 Selection of Activated Alumina The literature survey shows that cost of the treated water by activated alumina is less compared to other defluoridizing agents [15]. Compared to adsorption of CaCO3 (0.03 mg F− per g), activated alumina is proved to be better adsorbent (0.57 mg F− per g) [15, 16]. A number of researchers are worked on defluoridation of water using AA since the suggestion of Boruff [17]. Bulusu and Nawlakhe [18] established that its sorption capacity is variable and depends on water quality parameters, ionic environ- ment and regeneration procedures. Simultaneous occurrence of different reactions at AA surface (like ion exchange and hydrolysis) causes a variation in surface electro- kinetic properties [19]. It helps to increase the sorption of fluoride ions due to a decline of negative charges at its surface [18]. Hence, activated alumina was selected as an adsorbent for defluoridation of water. Commercially available technical grade activated alumina granules supplied by Sethiya Solvents & Chemicals, Tamil Nadu, were used. 13.2.2 Batch Adsorption Studies In each system, 300 mL of water (containing 2 ppm of fluoride, 113 ppm of chloride, 420 ppm of total hardness) is taken in a 500-mL polyethylene container and main- tained at 31 °C. The solution is stirred at 240 rpm mechanically for definite period after the addition of desired amounts of adsorbent. The suspension is filtered through a sintered crucible (G4). The filtrate is tested for fluoride by SPADNS method, chlo- ride by silver nitrate method and hardness by EDTA method [20]. The final fluoride concentrations were measured by Zr-SPADNS method [21]. The fluoride concen- tration in the sample after defluoridation is calculated from absorbance value of its coloured solution and standard curve. The same procedure is adopted for all the experiments carried out by varying amount of adsorbent, contact time, temperature and added salts. The percentage removal of fluoride/chloride/total hardness of water is calculated from C0 (initial concentration in solution) and Ce (final concentration in solution after adsorption).
  • 4. 176 S. Parveen et al. 13.3 Results and Discussion 13.3.1 Batch Mode Defluoridation of Water by Activated Alumina It is very well-known fact that activated alumina acts as an efficient defluoridizing agent. Therefore, it is thought worthwhile to know the effect of various factors affect- ing the defluoridation capacity of activated alumina, before designing the column for continuous defluoridation of water using activated alumina as an adsorbent. It is observed that with an increase in the amount of activated alumina, an increase in the % removal of fluoride is observed (Fig. 13.1a). It can be explained based on the increased active sites availability causing an improvement of active surface area, especially at higher adsorbent doses [22]. Afterwards, equilibrium is attained beyond certain dose. The effect of the agitation time on the removal of fluoride ion is shown in Fig. 13.1b, whichclearlyindicates that theremoval of fluorideis fast duringearlytime but turns out to be slow and almost decays with a further rise in the interaction period beyond 10 min. It hints that the fluoride removal rate is greater in the early phase because of availability of sufficient adsorbent surface area. A decrease in adsorption takes place with further increase in contact interaction period because of a decline in the accessibility to the active sites. Percentage of fluoride ion adsorption increased with an increase in contact time and the observed can be endorsed to the point that higher duration makes acquainted the fluoride ion to make adsorb on adsorbent [23]. The maximum adsorption percentage was recorded at 10 min with all adsorbents, and then onwards, sluggishness was observed. Per cent of defluoridation increased up to 31°C and then decreased (Fig. 13.2b). It shows that chemisorption is activated with an increase in temperature. Further confirmation of governing of chemisorption in the fluoride adsorption on activated alumina is evident as it obeys Langmuir’s adsorption isotherm [24]. To study the effect of the existence of anions (like chloride) and cations (like cal- cium) on the defluoridation capacity of water, sodium chloride and calcium chloride were added. There is no effect of added anions like chloride on the defluoridation of Fig. 13.1 Effect of a adsorbent dose and b time on % removal of fluoride
  • 5. 13 Design of a Domestic Defluoridizing Unit 177 Fig. 13.2 Effect of a salt type and amount, and b temperature on % removal of fluoride water as there is no change in the defluoridization capacity with a rise in [chloride ion]. But, the concentration of fluoride decreased progressively with an increase in the concentration of the added calcium chloride (Fig. 13.2a). The observed decrease in fluoride concentration can be attributed to the added calcium ion because there is no effect of chloride ion on defluoridation. Moreover, it is an established fact that the fluoride can be removed as calcium fluoride by the calcium ions. In spite of high affinity towards fluoride by adsorbents containing Al, Zr, Mg and Ca, the presence of some anions (nitrate, sulphate, bicarbonate and phosphate) decreases their affinity [25–27]. Adsorption of chloride and nitrate ions on activated alumina is negligible, whereas sulphate and bicarbonate ions adsorb fairly well. Further, an increase in bicarbonate ions decreases the adsorption of fluoride on activated alumina due to its competitive adsorption [15]. As many other anions are present in the groundwater taken in the present case, the efficiency of fluoride ion adsorption decreases further. Inviewofpracticalconditions,throughoutthepresentstudy,defluoridationstudies were carried out at neutral pH. However, defluoridation capacity of AA was reported as 3, 5.6 and 20 mg g−1 for alkaline, neutral and acidic water, respectively [24]. Davis and Leckie [28] reported that fluoride sorption capacity decreases with an increase in pH due to a decline in the establishment of ligand-like complexes. It is a known fact that defluoridation by adsorption is interfered by hydroxide ions. Defluoridation by activated alumina can be explained by Stern model of double layer. Charge potential on alumina is zero when pH is 9. As hydrogen ion is the potential-determining ion for the surface charge of AA, it is positively charged when [H+ ] is greater (pH < 9). Hence, negatively charged fluoride ion adsorbs on oppositely charged AA. In addition, adsorption process is also governed by “specificity factor” and adsorption order: F− OH− HCO3 − ≫ Cl− = SO4 2− [24]. Therefore, defluoridation capacity of AA decreases with an increase in [HCO3 − ].
  • 6. 178 S. Parveen et al. 13.3.2 Determination of Operational Defluoridation Capacity of Alumina 50 g of activated alumina is added to 1 l of water containing 2 ppm fluoride, 113 ppm chloride and 420 ppm of total hardness and allowed to be at equilibrium for 24 h and then filtered. The amount of removed fluoride is estimated colorimetrically based on the concentration of fluoride in the water before and after adsorption. The process is repeated with the same alumina with the addition of fresh samples of water added at the same amounts fluoride, chloride and total hardness. This process is repeated till there is no defluoridation by the alumina. The total defluoridation capacity is found to be 57 mg fluoride/50 g of alumina. Therefore, operational defluoridation capacity of the alumina is 1.14 mg fluoride g of alumina. The literature survey shows that adsorption capacities (mg g−1 ) of AA (OA-25 grade), AA (AD101-F grade), acidic alumina, modified AA and third aluminium hydrate (TAH) are compiled as 1.78, 0.42, 8.4, 0.76 and 25.8, respectively [29]. Probably, there exists a high variance in “degree of activation” in variety of alumina products. Another justification may be a difference in pH in addition to the brand of the product. Most of the previous research works involve the usage of distilled water for fluoride ion solution preparation and high grade alumina with high adsorption capacity. But in the present study, it is based on water having different salts and technical grade alumina. Therefore, the operational capacity—1.14 mg/g—is considered while designing the column for defluoridation. 13.3.3 Design of Continuous Defluoridizing Unit Compared to other defluoridation methods, packed bed adsorption method is more preferred. Some of its advantages are easier operation, reasonable capital and oper- ational costs, no sludge formation and easy replacement of bed [30]. Batch method faces three main problems, i.e. (1) drying of filter bed and hence shortening of life- time of filter for intermittent usage, (2) incomplete utilization of adsorbent and (3) limited release of defluoridate water at once. Hence, a continuous defluoridizing unit is designed in the present study. Combined filter contains two filter processes in the same structure to remove fluoride and microbes by using adsorbent and silver nitrate, respectively. However, in view of disadvantages like higher cost, maintenance requirement, low susceptibility to higher turbidity, etc., the concept of combined fil- ters was not considered. An attempt has been made to design the column using activated alumina as an adsorbent for defluoridation of water continuously for domestic purpose. A family of four members was taken as a model. The initial and final fluoride concentrations are taken as 2.0 and 0.7 ppm, respectively. Daily personal water demand = D = 3 l/consumer/day Number of users = N = 4
  • 7. 13 Design of a Domestic Defluoridizing Unit 179 Operation period = OP = 2 ½ months = 75 days Operational sorption capacity = C = 1.14 g/kg Bulk density of alumina = ρ = 1.12 kg/l Raw water fluoride concentration = Fi = 2.0 mg/l Mean fluoride concentration in treated water = 0.7 mg/l Volume ratio supernatant water/medium = VRSW/M = 0.2 Daily water treatment = Q = D × N = 12 l/day Overall quantity of treated water in a filter period = VT = Q × OP = 900 l Overall quantity of removed fluoride in a filter period = FT = VT ×(Fi −Ft) 1000 = 1.17 g Amount of Al2O3 required for renewal = M = FT/C = 1.03 kg Volume of Al2O3 in filter = VM = M/ρ = 0.916 l ∼= 0.95 l Treated no. of bed volumes during filter period = BV = VT VM = 982 Supernatant water volume capacity = VSW = VRSW/M × VM = 0.183 l ∼= 0.2 l Total volume of filter = VF = Vm + VSW = 0.95 + 0.2 = 1.15 l. 13.3.4 Corresponding Dimensions Karthikeyan et al. [24] studied the rate of water flow in a column filled with activated alumina. According to them, variation in column height and particle size causes a substantial alteration in water flow rate. Particle size increase caused a rise in pore volume leading to an enhancement of flow rate. Bed height increase results in an enhancement of offered resistance which leads to a decline in flow rate. In view of these two reasons, selection of bed height and particle size is the important parameter to be considered while designing a defluoridation unit. Important issue to be noted is that minimum contact period is required between adsorbent and fluoride ion to be removed. At the same time, very lower flow rate design will not be accepted by end- users. Taking into consideration the equal weightage of flow rate and defluoridation capacity, it is decided to choose the intermediate size of the particle in the range 140–180 mm because both factors are optimal in the chosen range. Based on it, fixation of column height was done. Moreover, it is always advisable to select the ratio of column diameter to particle diameter as more than 20 to decrease the channelling chances [31, 32]. Several trails were made with different dimensions, and it is found that the optimum diameter as 7 cm for the decided quantity of alumina. Filter diameter (selected) = Φ = 7 cm Total height of the filter = HF = VF/[π × (Φ/2)2 ] = 29.897 cm ∼= 30 cm. 13.3.5 Defluoridation Studies on the Designed Unit PVC pipe having an internal diameter of 7 cm was used for this study. The column was connected to a feed tank with inlet control valve. Activated alumina bed was fixed, and proper distribution in it was ensured by packing it between two circular
  • 8. 180 S. Parveen et al. Fig. 13.3 Design of the proposed house hold defluoridation unit perforated PVC sheets. Plug pairs encompass these sheets which function as filter- ing medium to remove any dust/dirt from inlet and support to the bed, respectively (Fig. 13.3). Random packing of adsorbent is ensured by initial filling of the column with deionized water followed by activated alumina, whereas the reverse filling order may result in a decline of adsorbent efficiency due to the development of air gaps which leads to further channelling phenomenon. A closely packed adsorbent bed was ensured by soaking with distilled water and leaving for overnight. It is a known fact that activated alumina on hydration changes from the mineral form boehmite (AlOOH) to gibbsite (γ-Al(OH)3) [33]. Further, it was also established that fluoride better uptake by it happens due to a change in surface morphology, which is done by soaking it for one day [34]. Hence, the above overnight soaking of bed with dis- tilled water also helps to improve defluoridation. Process was carried out at room temperature. Column kept filled with feed water even during resting period. Practical aspects in the usage of AA for defluoridation of water were studied by regulating the flow rate in order to maintain minimum 5 min contact time. Input and output were collected at regular intervals of time in order to analyse the fluoride concentration. The residual amount of fluorine in outlet water was found to be within permissi- ble limits. However, the three key issues involved in realization of any household defluoridation units are (1) motivation, (2) appropriate and cheap technique and (3) technical support including training on efficient regeneration to one of the villagers to continue without any support from external agencies [35]. Similar to defluorida- tion studies, decontamination units may be designed for the removal of heavy metals using agricultural waste as adsorbents [35–39].
  • 9. 13 Design of a Domestic Defluoridizing Unit 181 13.3.6 Regeneration of Bed A fourfold higher regeneration was observed with 0.1 N sodium hydroxide solution compared to 0.1 N hydrochloric acid solution. High negative charges are created on the surface of AA during elution of fluoride using sodium hydroxide. Hence, the already adsorbed F− experience repulsion from the surface leading to their diffusion into solution [24]. For regeneration, the exhausted AA was shifted into a bag made up of nylon mesh and immersed in alkali solution for overnight with intermittent stirring. A marginal decrease in adsorption capacity was observed even after 25 regeneration cycles. 13.4 Conclusions Lower values of operational defluoridation capacity of alumina can be explained based on the presence of competitive ions in the water to be treated. A continuous defluoridation unit was designed for domestic purpose using activated alumina as an adsorbent. The residual amount of fluorine in outlet water from the unit was found to be within permissible limits. Sodium hydroxide solution (0.1 N) was found to be the best regenerating agent for the exhausted bed. References 1. Ramesh,H.S.,Kamaraju,M.:Continuousflowdefluoridationunitforruralwatersupplyscheme of fluoride prone areas. In: World Environmental and Water Resource Congress 2006: Exam- ining the Confluence of Environmental and Water Concerns, pp. 1–10 (2006) 2. Sahu, P., Kisku, G.C., Singh, P.K., Kumar, V., Kumar, P., Shukla, N.: Multivariate statistical interpretation on seasonal variations of fluoride-contaminated groundwater quality of Lalganj Tehsil, Raebareli District (UP). India. Environ. Earth Sci 77(13), 484 (2018). https://doi.org/ 10.1007/s1266 3. Bureau of Indian Standards: Indian Standard: Drinking Water—Specification. Bureau of Indian Standards, New Delhi (2012) 4. Heikens, A., Sumarti, S., Van Bergen, M., Widianarko, B., Fokkert, L., Van Leeuwen, K., Seinen, W.: The impact of the hyperacid Ijen Crater Lake: risks of excess fluoride to human health. Sci. Total Environ. 346(1–3), 56–69 (2005). https://doi.org/10.1016/j.scitotenv.2004. 12.007 5. American Dental Association (ADA).: Fluoridation Facts. ADA Statement Commemorating the 60th Anniversary of Community Water Fluoridation, 211 East Chicago Avenue Chicago, Illinois 60611-2678 (2005) 6. Dissanayake, C.B.: The fluoride problem in the groundwater of Srilanka—environmental management and health. Int. J. Environ. Stud 19, 195–203 (1991). https://doi.org/10.1080/ 00207239108710658 7. Nie, Y., Hu, C., Kong, C.: Enhanced fluoride adsorption using Al (III) modified calcium hydrox- yapatite. J. Hazard. Mater. 233, 194–199 (2012). https://doi.org/10.1016/j.jhazmat.2012.07. 020
  • 10. 182 S. Parveen et al. 8. Tebutt, T.: Relationship Between Natural Water Quality and Health. United Nations Educa- tional, Scientific and Cultural Organization, Paris (1983) 9. Murray, J.J.: Appropriate Use of Fluorides for Human Health. World Health Organization, Geneva (1986) 10. Tekle-Haimanot, R., Melaku, Z., Kloos, H., Reimann, C., Fantaye, W., Zerihun, L., Bjorvatn, K.: The geographic distribution of fluoride in surface and groundwater in Ethiopia with an emphasis on the Rift Valley. Sci. Total Environ. 367(1), 182–190 (2006). https://doi.org/10. 1016/j.scitotenv.2005.11.003 11. Fawell, J., Bailey, K., Chilton, J., Dahi, E., Magara, Y.: Fluoride in drinking-water. IWA pub- lishing World Health Organization and IWA Publishing, London (2006) 12. Pietrelli, L.: Fluoride wastewater treatment by adsorption onto metallurgical grade alumina. Anal. Chim. 95, 303–312 (2005) 13. Maheshwari, R.C.: Fluoride in drinking water and its removal. J. Hazard. Mater. 137(1), 456–463 (2006). https://doi.org/10.1016/j.jhazmat.2006.02.024 14. Mehari, B.B., Mayabi, A.O., Kakoi, B.K.: Development of household defluoridation unit based on crushed burnt clay pot as sorbent medium: a case of Keren Community, Eritrea. Environ. Nat. Resour. Res. 4(3), 67 (2014) 15. Samrat, M.V., Rao, K.K., SenGupta, A.K., Riotte, J., Mudakavi, J.R.: Defluoridation of reject water from a reverse osmosis unit and synthetic water using adsorption. J. Water Process Eng. 23, 327–337 (2018). https://doi.org/10.1016/j.jwpe.2017.07.015 16. Babu, C.A., Sujish, D., Murugappa, M.S., Mohanakrishnan, G., Kalyanasundaram, P., Raj, B.: A comprehensive treatment method for defluoridation of drinking water. Indian J. Chem. Technol. 18, 314–318 (2011) 17. Boruff, C.S.: Removal of fluorides from drinking waters. Ind. Eng. Chem. 26(1), 69–71 (1934). https://doi.org/10.1021/ie50289a016 18. Bulusu, K.R., Nawlakhe, W.G.: Defluoridation of water with activated alumina: batch opera- tions. Indian J. Environ. Health 30(3), 262–299 (1988) 19. Benjamin, M.M., Leckie, J.O.: Conceptual model for metal-ligand-surface interactions dur- ing adsorption. Environ. Sci. Technol. 15(9), 1050–1057 (1981). https://doi.org/10.1021/ es00091a003 20. American Public Health Association, American Water Works Association.: Standard Methods for the Examination of Water and Wastewater. American public health association (1989). 21. Bellack, E., Schouboe, P.J.: Rapid photometric determination of fluoride in water. Use of sodium 2-(p-sulfophenylazo)-1, 8-dihydroxynaphthalene-3, 6-disulfonate-zirconium lake. Anal. Chem. 30(12):2032–2034 (1958). https://doi.org/10.1021/ac60144a050 22. Gupta, V.K., Sharma, S.: Removal of cadmium and zinc from aqueous solutions using red mud. Environ. Sci. Technol. 36(16), 3612–3617 (2002). https://doi.org/10.1021/es020010v 23. Bhattacharya, A.K., Mandal, S.N., Das, S.K.: Adsorption of Zn (II) from aqueous solution by using different adsorbents. Chem. Eng. J. 123(1–2), 43–51 (2006). https://doi.org/10.1016/j. cej.2006.06.012 24. Karthikeyan, G., Meenakshi, S., Apparel, B.V.: Defluoridation properties of activated alumina. In: Dahi, E., Nielsen, J.M. (eds.) 2nd International Workshop on Fluorosis Prevention and Defluoridation of Water, pp. 19–25 (1997) 25. Loganathan, P., Vigneswaran, S., Kandasamy, J., Naidu, R.: Defluoridation of drinking water using adsorption processes. J. Hazard. Mater. 248, 1–9 (2013). https://doi.org/10.1016/j. jhazmat.2012.12.043 26. Mondal, P., George, S.: A review on adsorbents used for defluoridation of drinking water. Rev. Environ. Sci. Biotechnol. 14(2), 195–210 (2015). https://doi.org/10.1007/s11157-014-9356-0 27. Velazquez-Jimenez, L.H., Vences-Alvarez, E., Flores-Arciniega, J.L., Flores-Zuniga, H., Rangel-Mendez, J.R.: Water defluoridation with special emphasis on adsorbents-containing metal oxides and/or hydroxides: a review. Sep. Purif. Technol. 150, 292–307 (2015). https:// doi.org/10.1016/j.seppur.2015.07.006 28. Davis, J.A., Leckie, J.O.: Surface ionization and complexation at the oxide/water interface. 3. Adsorption of anions. J. Colloid Interface Sci. 74(1):32–43 (1980). https://doi.org/10.1016/ 0021-9797(80)90168-x
  • 11. 13 Design of a Domestic Defluoridizing Unit 183 29. Mulugeta, E., Zewge, F., Chandravanshi, B.S.: Development of a household water defluorida- tion process using aluminium hydroxide based adsorbent. Water Environ. Res. 87(6), 524–532 (2015). https://doi.org/10.2175/106143014X13975035525627 30. Eyobel, M.D.: Removal of fluoride from water using granular aluminium hydroxide: adsorption in a fixed bed column. M.Sc. Thesis, Environmental Science Program, Addis Ababa University, Ethiopia (2006) 31. LeVan, M.D., Vermeulen, T.: Channeling and bed-diameter effects in fixed-bed adsorber per- formance. AIChE Symp 80(233), 34–43 (1984) 32. Zhao, D., SenGupta, A.K.: Ligand separation with a copper (II)-loaded polymeric ligand exchanger. Ind. Eng. Chem. Res. 39(2), 455–462 (2000). https://doi.org/10.1021/ie990740k 33. Dyer, C., Hendra, P.J., Forsling, W., Ranheimer, M.: Surface hydration of aqueous γ-Al2O3 studied by Fourier transform Raman and infrared spectroscopy—I. Initial results. Spec- trochim. Acta Part A: Mol. Spectrosc. 49(5–6), 691–705 (1993). https://doi.org/10.1016/0584- 8539(93)80092-o 34. Shreyas, L., Kanwar, L., Rao, K.K.: Chemical engineering and the mitigation of fluorosis. Indian Chem. Eng. 55(1), 38–49 (2013). https://doi.org/10.1080/00194506.2013.785116 35. Bregnhoj, H.: Critical sustainability parameters in defluoridation of drinking water. In: Dahi, E., Nielsen, J.M. (eds.) Proceeding of 2nd International Workshop on Fluorosis and Defluoridation of Water. International Society of Fluoride Research (1997) 36. Mokkapati, R.P., Mokkapati, J.M., Ratnakaram, V.N.: Chemical oxygen demand reduction from coffee processing waste water—a comparative study on usage of biosorbents prepared from agricultural wastes. Glob. Nest. J. 17, 291–300 (2015) 37. Mokkapati, R.P., Mokkapati, J.M., Ratnakaram, V.N.: Kinetic, thermodynamic and equilibrium studies on removal of hexavalent chromium from aqueous solutions using agro-waste bioma- terials, casuarina equisetifolia L. and sorghum bicolor. Korean J. Chem. Eng. 33, 2374–2383 (2016). https://doi.org/10.1007/s11814-016-0078-6 38. Mokkapati, R.P., Mokkapati, J.M., Ratnakaram, V.N.: Kinetic, isotherm and thermodynamics investigation on adsorption of divalent copper using agro-waste biomaterials, Musa acuminata, Casuarina equisetifolia L. and Sorghum bicolor. Polish J. Chem. Tech. 18(2):68–77 (2016). https://doi.org/10.1515/pjct-2016-0031 39. Mokkapati, R.P., Ratnakaram, V.N., Mokkapati, J.M.: Utilization of agro-waste for removal of toxic hexavalent chromium: surface interaction and mass transfer studies. Int. J. Environ. Sci. Technol. 15(4), 875–886 (2018). https://doi.org/10.1007/s13762-017-1443-7