TI199C/07/EN/13.11
71130252
Technical Information
Liquisys M COM223/253
Dissolved Oxygen Measurement
Transmitter for oxygen sensors
Application
The modular design of the transmitter allows easy adaption to a
variety of customer requirements. Starting with the basic version
for "measurement and alarm generation", the transmitter can be
equipped with additional software and hardware modules for
special applications. These modules can also be retrofitted as
required.
Areas of Application
• Sewage treatment plants
• Wastewater treatment
• Water treatment
• Drinking water
• Surface water: rivers, lakes, sea
• Fish farming
• Boiler feed water (trace measurement)
Your benefits
• Field or panel-mounted housing
• Universal application
• For analogue and digital sensors
• Simple handling
– Logically arranged menu structure
– Simple single-point calibration in air, air-saturated water or
in the medium is possible
• Safe operation
– Excellent interference immunity
– Direct access for manual contact control
– User-defined alarm configuration
The basic unit can be extended with:
• 2 or 4 additional contacts for use as:
– Limit contacts (also for temperature)
– P(ID) controller
– Timer for simple rinse processes
– Complete cleaning with Chemoclean
• Plus package:
– User-defined current output characteristics
– Automatic cleaning trigger on alarm or limit violation
– Process monitoring
– Sensor live check
• HART or PROFIBUS-PA/-DP
• 2nd current output for temperature, main measured value or
actuating variable
• Current input for flow rate monitoring with controller shut off
or for feedforward control
Liquisys M COM2x3
2 Endress+Hauser
Function and system design
Features of the basic version Measurement of oxygen content and of partial oxygen pressure
The oxygen content is displayed in mg/l or in %SAT, the partial oxygen pressure is displayed in hPa. This is
selected via the menu. The temperature is displayed at the same time or, if desired, not shown at all.
Calibration
The amperometric sensors are zero-current-free and only require a single-point calibration. This takes place
in air, air-saturated water or by reference calibration in the medium.
The optical sensor will be calibrated before shipment. If necessary it can be calibrated in air and for zero point.
Configuration
Different alarms are required depending on application and operator. Therefore the transmitter permits
independent configuration of the alarm contact and error current for each individual error. Unnecessary
or undesirable alarms can be suppressed in this manner. Up to four contacts can be used as limit contacts
(also for temperature), to implement a P(ID) controller or for cleaning functions.
Direct manual operation of the contacts (bypassing the menu) provides quick access to limit, control or
cleaning contacts, permitting speedy correction of deviations.
The serial numbers of the instrument and modules and the order code can be called up on the display.
Additional functions of version
WX/WS/DS
Automatic pressure compensation
Oxygen concentration is not only dependent on altitude but also on weather conditions (pressure). Automatic
pressure compensation takes these fluctuations into account.
Additional functions of the
Plus package
Current output configuration
In order to output wide measuring ranges while still achieving a high resolution in specific ranges, the current
output can be configured as required via a table. This permits bilinear or quasi-logarithmic curves, etc.
Process Check System (PCS)
It comprises two independent safety functions:
• Errors in applications without control are detected by monitoring the limit beween plausible and implausible
measured values, i.e. the alarm theshold.
• Errors in applications with control are detected by the controller monitor which monitors freely
adjustable, maximum permissible time intervals and reference value overshoot or undershoot.
Live check, sensor activity monitoring
The live check issues an alarm when the sensor signal does not change over a defined period of time. This may
be caused by blocking, passivation, separation from the process, etc.
Second current output The second current output can be configured for temperature, main measured value (oxygen content, partial
oxygen pressure) or actuating variable.
Current input The current input of the transmitter allows two different applications: controller shut-down in case of lower
flow rate violation or total failure in the main flow as well as feedforward control. Both functions are also
combinable.
Liquisys M COM2x3
Endress+Hauser 3
Measuring system A complete measuring system comprises:
Variant 1 (DX/DS with COS41)
• The transmitter Liquisys M COM223 or COM253 in version DX or DS
• An oxygen sensor COS41
• An immersion, flow or retractable assembly
Options: extension cable CMK, junction box VBM
Variant 2 (WX/WS with COS31, COS61 or COS71)
• The transmitter Liquisys M COM223 or COM253 in version WX or WS
• An oxygen sensor COS31, COS61 or COS71
• An immersion, flow or retractable assembly
Options: extension cable OMK, junction box VS
C07-COM2x3xx-14-06-00-xx-002.eps
Complete measuring system Liquisys M COM223/253
1
2
3
4
Oxygen sensor
Immersion assembly CYA112
Holder CYH112
Weather protection cover CYY101
5
6
7
Liquisys M COM253
Liquisys M COM223
Retractable assembly COA451
CAL REL
REL1
REL1
ALARM
REL2
REL2E
CAL REL
REL1
REL1
ALARM
REL2
REL2E
1
2
3 5
67
4
Liquisys M COM2x3
4 Endress+Hauser
Input
Measured variables Oxygen
Temperature
Measuring range
Cable specification
O2 signal input
Binary inputs
Current input 4 to 20 mA, galvanically separated
Load: 260 Ω at 20 mA (voltage drop 5.2 V)
Output
Output signal 0/4 to 20 mA, galvanically separated, active
COS31:
Oxygen concentration 0 ... 20 / 0 ... 60 mg/l
Oxygen saturation index 0 ... 200 / 0 ... 600 % SAT
Oxygen partial pressure 0 ... 400 / 0 ... 1200 hPa
COS41, COS61:
Oxygen concentration 0 ... 20 mg/l
Oxygen saturation index 0 ... 200 % SAT
Oxygen partial pressure 0 ... 400 hPa
COS71:
Oxygen concentration 0 ... 20 mg/l
Oxygen saturation index 0 ... 200 % SAT
Oxygen partial pressure 0 ... 400 hPa
Temperature: -10 ... 60 °C (14 ... 140 °F)
Cable length:
COS31, COS61, COS71 max. 100 m (328 ft)
COS41 max. 50 m (164 ft)
Version DX/DS: 0 ... 3000 nA
Version WX/WS: digital communication or 0 ... -7500 mV
Voltage: 10 to 50 V
Power consumption: max. 10 mA
HART
Signal coding Frequency Shift Keying (FSK) + 0.5 mA via current output signal
Data transfer rate 1200 Baud
Galvanic isolation yes
PROFIBUS PA
Signal coding Manchester Bus Powered (MBP)
Data transfer rate 31.25 kBit/s, voltage mode
Galvanic isolation yes (IO-Module)
PROFIBUS DP
Signal coding RS485
Data transfer rate 9.6 kBd, 19.2 kBd, 93.75 kBd, 187.5 kBd, 500 kBd, 1.5 MBd
Galvanic isolation yes (IO-Module)
Liquisys M COM2x3
Endress+Hauser 5
Signal on alarm 2.4 or 22 mA in case of an error
Load maximum 500 Ω
Transmission range
Resolution max. 700 digits/mA
Isolation voltage max. 350 VRMS/500 V DC
Overvoltage protection according to EN 61000-4-5
Auxiliary voltage output
Contact outputs
Limit contactor
Controller
Alarm
COS31:
Oxygen concentration Δ 0.2 ... Δ 20 / Δ 0.6 ... Δ 60 mg/l
Oxygen saturation index Δ 2 ... Δ 200 / Δ 6 ... Δ 600 % SAT
Oxygen partial pressure Δ 4 .... Δ 400 / Δ 12 ... Δ 1200 hPa
COS41, COS61:
Oxygen concentration Δ 0.2 ... Δ 20 mg/l
Oxygen saturation index Δ 2 ... Δ 200 % SAT
Oxygen partial pressure Δ 4 .... Δ 400 hPa
COS71:
Oxygen concentration Δ 0.02 ... Δ 20 mg/l
Oxygen saturation index Δ 0.2 ... Δ 200 % SAT
Oxygen partial pressure Δ 0.4 .... Δ 400 hPa
Temperature: Δ 7 ... Δ 70 °C
Output voltage: 15 V ± 0.6
Output current: max. 10 mA
Switching current with ohmic load (cos ϕ = 1): max. 2 A
Switching current with inductive load (cos ϕ = 0.4): max. 2 A
Switching voltage: max. 250 V AC, 30 V DC
Switching power with ohmic load (cos ϕ = 1): max. 500 VA AC, 60 W DC
Switching power with inductive load (cos ϕ = 0.4): max. 500 VA AC, 60 W DC
Pickup/dropout delay: 0 to 2000 s
Function (adjustable): pulse length/pulse frequency controller
Controller response: PID
Control gain Kp: 0.01 to 20.00
Integral action time Tn: 0.0 to 999.9 min
Derivative action time Tv: 0.0 to 999.9 min
Period for pulse length controller: 0.5 to 999.9 s
Frequency for pulse frequency controller: 60 to 180 min-1
Basic load: 0 to 40% of max. set value
Function (switchable): latching/momentary contact
Alarm threshold adjustment range: O2 / temperature: entire measuring range, depending
on sensor type
Alarm delay: 0 ... 2000 s (min)
Monitoring time lower limit violation: 0 ... 2000 min
Monitoring time upper limit violation: 0 ... 2000 min
Liquisys M COM2x3
6 Endress+Hauser
Protocol specific data HART
Manufacturer ID 11h
Device type code 0094h
Transmitter specific revision 0001h
HART specification 5.0
DD files www.products.endress.com/profibus
Load HART 250 Ω
Device variables None (dynamic variables PV, SV, only)
Features supported -
PROFIBUS PA
Manufacturer ID 11h
Ident number 1518h
Device revision 11h
Profile version 2.0
GSD files www.products.endress.com/profibus
GSD file version
Output values Main value, temperature value
Input values Display value of PLC
Features supported Device locking: The device can be locked by hardware or software.
PROFIBUS DP
Manufacturer ID 11h
Ident number 151Eh
Profile version 2.0
GSD files www.products.endress.com/profibus
GSD file version
Output values Main value, temperature value
Input values Display value of PLC
Features supported Device locking: The device can be locked by hardware or software.
Liquisys M COM2x3
Endress+Hauser 7
Power supply
Electrical connection
COM2x3-DX/DS
The device is approved for protection class II and is generally operated without a protective earth connection.
a0015422
Electrical connection version DX or DS
A
B
C
D
E
F
*
Sensor COS41
Signal output 1 oxygen
Signal output 2 temperature
Binary input 1 (Hold)
Binary input 2 (Chemoclean)
Aux. voltage output
Aux. voltage output terminal 85/86 applicable
G
H
I
J
K
L
M
Alarm (current-free contact position)
Relay 1 (current-free contact position)
Relay 2 (current-free contact position)
Relay 3 (current-free contact position)
Relay 4 (current-free contact position)
Current input 4 ... 20 mA
Power supply
Liquisys M COM2x3
8 Endress+Hauser
Electrical connection
COM2x3-WX/WS1)
The device is approved for protection class II and is generally operated without a protective earth connection.
Note!
The signals "Sensor signal" and "Alarm" are not used by COS61 and the TOP68-versions.
1) COS61 sensors from serial no. 79xxxx
C07-COM2x3xx-04-06-00-xx-003.eps
Electrical connection version WX/WS
A
B
C
D
E
F
G
H
*
Oxygen sensor COS31/61/71
Junction box VS with extension
COM253: Plug connection for oxygen sensor
COM223: The sensor cable plug must be removed or
junction box VS used
Signal output 1 oxygen
Signal output 2 temperature
Binary input 1 (Hold)
Binary input 2 (Chemoclean)
Aux. voltage output
Aux. voltage output terminal 85/86 applicable
I
J
K
L
M
N
O
Alarm (current-free contact position)
Relay 1 (current-free contact position)
Relay 2 (current-free contact position)
Relay 3 (current-free contact position)
Relay 4 (current-free contact position)
Current input 4 ... 20 mA
Power supply
47
48
49
57
58
59
41
42
43
15 V
85
86
10-50 V
81
93
82
94
10-50 V
mA
31
32
mA
33
34
51
52
53
54
55
56
18
96
97
19
S
O2
O2
GN
PK
BU
8,5 V DC
88
0
87 +
0
- 8,5 V DC
WH
BN
GY
YE1
2
5
4
3
7
6GN
PK
BU
WH
BN
GY
YE
RS 485
23 +
24 -
mA
L+
L–N
L1
~ =
A B C
D
E
F
G
H
I
J
K
L
M
N
O
*
*
B
A
Liquisys M COM2x3
Endress+Hauser 9
Sensor cable The oxygen sensors are supplied with the measuring cable. To extend this cable, you have to use a junction
box and an extension cable (see "Accessories").
Supply voltage Depending on ordered version:
100/115/230 V AC +10/-15 %, 48 to 62 Hz
24 V AC/DC +20/-15 %
Fieldbus connection
Power consumption max. 7.5 VA
Mains protection Fine-wire fuse, medium-slow blow 250 V/3.15 A
a0015423
COS41 to COM2x3-DX/DS with CYK71 cable
a0015424
COS31/611)
/71 to COM2x3-WX/WS
1) from serial no. 79xxxx
HART
Supply voltage n/a, active current outputs
Integrated reverse voltage protection n/a, active current outputs
PROFIBUS PA
Supply voltage 9 V to 32 V, max. 35 V
Polarity sensitive no
FISCO/FNICO compliant acc. to IEC 60079-27 no
PROFIBUS DP
Supply voltage 9 V to 32 V, max. 35 V
Polarity sensitive n/a
FISCO/FNICO compliant acc. to IEC 60079-27 no
Liquisys M COM2x3
10 Endress+Hauser
Performance characteristics
Resolution
Maximum measured error2)
Repeatabilitya
max. 0.2 % of measuring range
Temperature compensation
range
0 ... 50 °C (32 ... 104 °F)
Pressure compensation range 500 ... 1100 hPa
Altitude adjustment range 0 ... 4000 m (0 ... 13124 ft)
Salinity adjustment range 0 ... 4 %
Slope adjustment range
Oxygen:
COS31, COS41, COS61: 0.01 mg/l / 0.1 % SAT / 1 hPa
COS71: 0.001 mg/l / 0.1 % SAT / 1 hPa
Temperature: 0.1 °C
2) acc. to IEC 746-1, for nominal operating conditions
Display
Oxygen: max. 0.5 % of measuring range
Temperature: max. 1.0 % of measuring range
Signal output
Oxygen: max. 0.75 % of measuring range
Temperature: max. 1.25 % of measuring range
COS31: 75 ... 140 % (nominal 290 nA, in air, 20 °C (68 °F), 1013 hPa)
COS41: 75 ... 140 % (nominal 290 nA, in air, 20 °C (68 °F), 1013 hPa)
COS61: 75 ... 140 % (nominal 1340 nA, in air, 20 °C (68 °F), 1013 hPa)
COS71: 50 ... 150 % (nominal 8000 nA, in air, 20 °C (68 °F), 1013 hPa)
Liquisys M COM2x3
Endress+Hauser 11
Installation
Installation instructions
a0005733
Field instrument
a0005737
Mounting on pipes
1 - 3 Mounting screws and mounting plate
CAL REL
REL1
REL1
ALARM
REL2
REL2E
Pg 7
Pg 16
M5
11/
0.43
Ø6/
Ø0.24
115 / 4.53
157/6.18
247/9.72
70/2.76
70 / 2.76
154 / 6.06
170 / 6.69
mm / inch
Pg 13.5
1
2
3
1
1
3
Ømax.60/
2.36
mm / inch
Liquisys M COM2x3
12 Endress+Hauser
a0005734
View into the field instrument
1
2
3
4
Removable electronics box
Partition plate
Terminal blocks
Fuse
a0005736
Wall mounting of the field instrument
1 Mounting holes
2 Protecting cap
a0005738
Mounting of the field instrument with mounting post and weather protection cover
1 - 3 Mounting holes
1
2
3
4
1
2
154 / 6.06
mm / inch Ø6/
Ø0.24
3
1
2
3
Liquisys M COM2x3
Endress+Hauser 13
a0005735
Dimensions panel-mounted instrument
a0005739
Installation of the panel-mounted instrument
1 Wall of control cabinet
2 Gasket
3 Tensioning screws
* Required installation depth
90 / 3.54
139/5.47
96/3.78
6 /
0.24
mm / inch
92 / 3.62
149.5/5.89
1
2
3
3
3
92 / 3.62+0.5 +0.02
92/3.62
+0.5+0.02
90/3.54
57/2.24
33/
1.30
approx. 25 /
0.98
139 / 5.47
max. 45 /
1.77 6 /
0.24
96/3.78
92/
3.62
approx. 165 / 6.50*
mm / inch
Liquisys M COM2x3
14 Endress+Hauser
Environment
Ambient temperature -10 to +55 °C (+14 to +131 °F)
Storage temperature –25 to +65 °C (-13 to +149 °F)
Electromagnetic compatibility Interference emission and interference immunity as per EN 61326-1:2006, EN 61326-2-3:2006
Ingress protection
Electrical safety according EN/IEC 61010-1:2001, Installation Category II, for use up to 2000 m above sea level
CSA Apparatus with CSA General Purpose Approval are certified for indoor use.
Relative humidity 10 to 95%, non-condensing
Pollution degree The product is suitable for pollution degree 2.
Mechanical construction
Dimensions
Weight
Materials
Terminals
Panel mounted instrument: IP 54 (front), IP 30 (housing)
Field instrument: IP 65 / tightness acc. to NEMA 4X
Panel mounted instrument: 96 x 96 x 145 mm (3.78 x 3.78 x 5.71 inches)
Installation depth: approx. 165 mm (6.50")
Field instrument: 247 x 170 x 115 mm (9.72 x 6.69 x 4.53 inches)
Panel mounted instrument: max. 0.7 kg (1.5 lb)
Field instrument: max. 2.3 kg (5.1 lb)
Housing of panel mounted instrument: Polycarbonate
Field housing: ABS PC Fr
Front membrane: Polyester, UV-resistant
Cross section max. 2.5 mm2
Liquisys M COM2x3
Endress+Hauser 15
Operability
Operating concept All instrument control functions are arranged in a logical menu structure. Following access code entry, the
individual parameters can be easily selected and modified as needed.
Display elements
C07-COM2x3xx-19-06-00-en-001.eps
Operating elements
The display simultaneously shows the current measured value and the temperature - the essential process data.
Brief information texts in the configuration menu provide assistance with parameter configuration.
Certificates and approvals
4 symbol Declaration of conformity
The product meets the requirements of the harmonized European standards. It thus complies with the legal
requirements of the EC directives.
The manufacturer confirms successful testing of the product by affixing the 4 symbol.
CSA General purpose C.M2.3-..2...
C.M2.3-..3...
C.M2.3-..7...
1.85
mg/l
R232
1
2
3
4
5
6
7
Setpoint
Liquisys M COM2x3
16 Endress+Hauser
Ordering information
Product structure
Additional functions of the
Plus package
• Current output table to cover large areas with varying resolution, fields O23x
• Process Check System (PCS): live check of the sensor, function group P
• Automatic cleaning function start, field F8
• At version DS: air pressure measurement
Scope of delivery The delivery of the field instrument includes:
• 1 transmitter COM253
• 1 plug-in screw terminal
• 1 cable gland Pg 7
• 1 cable gland Pg 16 reduced
• 2 cable glands Pg 13.5
• 1 Operating Instructions BA199C/07/EN
• versions with HART communication:
1 Operating Instructions Field Communication with HART, BA208C/07/EN
• versions with PROFIBUS communication:
1 Operating Instructions Field Communication with PROFIBUS PA/DP, BA209C/07/EN
The delivery of the panel mounted instrument includes:
• 1 transmitter COM223
• 1 set of plug-in screw terminals
• 2 tensioning screws
• 1 BNC-plug (solder-free)
• 1 Operating Instructions BA199C/07/EN
• versions with HART communication:
1 Operating Instructions Field Communication with HART, BA208C/07/EN
• versions with PROFIBUS communication:
1 Operating Instructions Field Communication with PROFIBUS PA/DP, BA209C/07/EN
Input, software version
DX Sensor COS41 / 4 / 4HD, basic functions
DS Sensor COS41 / 4 / 4HD, with additional functions (Plus package)
WX Sensor COS31 / 61 / 71 / 3 / 3HD, basic functions
WS Sensor COS31 / 61 / 71 / 3 / 3HD, with additional functions (Plus package)
Power supply, approval
0 230 V AC
1 115 V AC
2 230 V AC; CSA Gen. Purp.
3 115 V AC; CSA Gen. Purp.
5 100 V AC
7 24 V AC/DC; CSA Gen. Purp.
8 24 V AC/DC
Output
0 1 x 20 mA, primary value
1 2 x 20 mA, primary value + secondary value
3 PROFIBUS PA
4 PROFIBUS DP
5 1 x 20 mA, primary value, HART
6 2 x 20 mA, primary value, HART + secondary value
Additional contacts
05 not selected
10 2 relays (limit/P(ID)/timer)
15 4 relays (limit/P(ID)/Chemoclean) (not with PROFIBUS DP)
16 4 relays (limit/P(ID)/timer) (not with PROFIBUS DP)
20 1 x 4 ... 20 mA input + 2 relays (limit/P(ID)/timer)
25 1 x 4 ... 20 mA input + 4 relays (limit/P(ID)/Chemoclean) (not with PROFIBUS DP)
26 1 x 4 ... 20 mA input + 4 relays (limit/P(ID)/timer) (not with PROFIBUS DP)
Marking
1 Tagging (Tag), see additional spec.
COM253-
complete order code
COM223-
Liquisys M COM2x3
Endress+Hauser 17
Accessories
Sensors Oxymax W COS31
• Oxygen sensor for drinking water and wastewater measurements, potentiostatic amperometric principle
• Material: stainless steel 1.4571 (AISI 316 Ti)
• Ordering acc. to product structure, see Technical Information TI285C/07/EN
Oxymax W COS41
• Oxygen sensor for drinking water and wastewater measurements, amperometric principle
• Material: POM
• Ordering acc. to product structure, see Technical Information TI284C/07/EN
Oxymax W COS71
• Oxygen sensor for trace measurement, potentiostatic amperometric principle
• Material: stainless steel 1.4571 (AISI 316 Ti)
• Ordering acc. to product structure, see Technical Information TI286/07/EN
Oxymax W COS61
• Optical oxygen sensor for drinking water and wastewater measurements, fluorescence quenching principle
• Material: stainless steel 1.4571 (AISI 316 Ti)
• Ordering acc. to product structure, see Technical Information TI387C/07/EN
Connection accessories OMK measuring cable
• non-terminated measuring cable for oxygen sensors COS31, COS61 and COS71,
for extension between junction box VS and transmitter
• Sold by the meter, order no. 50004124
CMK measuring cable
• non-terminated measuring cable for oxygen sensor COS41,
for extension between junction box VBM and transmitter
• Sold by the meter, order no. 50005374
VS junction box
• With plug-in socket and 7-pole plug
• For cable extension from sensor (COS71, COS61, COS31, COS3 with SXP connector) to transmitter, IP 65;
• Order no. 50001054
Junction box VBM
• for cable extension for sensors COS41, COS4 (fixed cable versions)
• with 10 terminals, IP 65 / NEMA 4X
• Order numbers:
– Cable entry Pg 13.5: 50003987
– Cable entry NPT ½": 51500177
Liquisys M COM2x3
18 Endress+Hauser
Mounting accessories CYY101 weather protection cover for field devices, absolutely essential if operating the unit outdoors
• Material: stainless steel 1.4031 (AISI 304)
• Order No. CYY101-A
Post mounting kit
• For mounting of field housing on horizontal or vertical pipes (Ø max. 60 mm (2.36"))
• Material: stainless steel 1.4301
• order no. 50086842
a0005676
Post mounting kit
a0012427
Weather protection cover for field devices
* Wall and post mounting
** Rail mounting
70 / 2.76
90 / 3.54
Ø 6 / 0.24
Ø8/
0.31
70/2.76
90/3.54
M6
60/2.36
90 / 3.54
70 / 2.76
Ø8/
0.31
30/
1.18
Ø max. 60 / 2.36
mm / inch
Liquisys M COM2x3
Endress+Hauser 19
CYY102 universal post
• Square pipe for mounting transmitters
• Material: stainless steel 1.4301 (AISI 304)
• Order No. CYY102-A
a0005742
Universal post
Optoscope Optoscope
• Interface between transmitter and PC / laptop for service purposes.
• The Windows software "Scopeware" required for the PC or laptop is supplied with the Optoscope. The
Optoscope is supplied in a sturdy plastic case with all the accessories required.
• Order no. 51500650
1495/58.86
60 x 60 /
2.36 x 2.36
120 /
4.72
150/
5.91
mm/inch
TI199C/07/EN/13.11
71130252
FM+SGML 6.0

More Related Content

PDF
NEC 2020.pdf
PDF
05. cálculo eléctrico y mecánico laat
PDF
Lm 741 datasheet
PDF
Canalizacion unistrut
PDF
Net boss xt datasheet
PDF
Resonant Test System
PDF
Electrical Drawings and Schematics
PDF
TABLA LUXES_CNE.pdf
NEC 2020.pdf
05. cálculo eléctrico y mecánico laat
Lm 741 datasheet
Canalizacion unistrut
Net boss xt datasheet
Resonant Test System
Electrical Drawings and Schematics
TABLA LUXES_CNE.pdf

What's hot (9)

PDF
Reticle manual | Vortex Viper PST Gen II EBR-MOA
PDF
Original NPN Transistor LBC817 BC817 6C SMD Code 500mA 45V SOT23
PPTX
DETALLES DE INSTALACIÓN DE TUBERÍAS Y CAJAS DE PASE.pptx
PDF
하이웍스 구축부터 활용까지-하이웍스 이용 매뉴얼
PDF
射頻電子 - [第一章] 知識回顧與通訊系統簡介
PDF
Selección, instalación y mantenimiento de banco de condensadores
PDF
7 E Cantida De Cables Por Tuberia Conduit
PDF
Cert 1279.pdf
Reticle manual | Vortex Viper PST Gen II EBR-MOA
Original NPN Transistor LBC817 BC817 6C SMD Code 500mA 45V SOT23
DETALLES DE INSTALACIÓN DE TUBERÍAS Y CAJAS DE PASE.pptx
하이웍스 구축부터 활용까지-하이웍스 이용 매뉴얼
射頻電子 - [第一章] 知識回顧與通訊系統簡介
Selección, instalación y mantenimiento de banco de condensadores
7 E Cantida De Cables Por Tuberia Conduit
Cert 1279.pdf
Ad

Similar to Dissolved Oxygen Transmitter-Liquisys M COM223/253 (20)

PDF
Dissolved Oxygen Transmitter-Liquisys M COM223F/253F
PDF
Oxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygen
PDF
Oxymax cos61 d endress+hauser datasheet-dissolved oxygen measurement
PDF
Dissolved Oxygen Sensors-Oxymax COS61/COS61D
PDF
Dissolved Oxygen Sensors-Oxymax COS22/22D
PDF
CUM223 253 endress+hauser datasheet-turbidity and suspended solids transmitter
PDF
Liquisys m cpm223 253 endress+hauser datasheet-p-h orp measurement
PDF
pH.ORP Transmitter-Analog and digital glass
PDF
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
PDF
Dissolved Oxygen Sensors-Oxymax COS51D
PDF
Oxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygen
PDF
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
PPTX
PBL FINAL PPT- GROUP 15.pptx
PPT
GPO Application Dataset
PDF
Analox Sensor Technology Laboratory Brochure
PPT
GPO Customer Presentation
PDF
In Situ Oxygen Transmitter For Combustion Monitoring
PDF
Head Mounted Temperature Transmitter
PDF
Magnetic flow meter for industrial process measurement
PDF
Module -1.pdf
Dissolved Oxygen Transmitter-Liquisys M COM223F/253F
Oxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygen
Oxymax cos61 d endress+hauser datasheet-dissolved oxygen measurement
Dissolved Oxygen Sensors-Oxymax COS61/COS61D
Dissolved Oxygen Sensors-Oxymax COS22/22D
CUM223 253 endress+hauser datasheet-turbidity and suspended solids transmitter
Liquisys m cpm223 253 endress+hauser datasheet-p-h orp measurement
pH.ORP Transmitter-Analog and digital glass
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
Dissolved Oxygen Sensors-Oxymax COS51D
Oxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygen
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
PBL FINAL PPT- GROUP 15.pptx
GPO Application Dataset
Analox Sensor Technology Laboratory Brochure
GPO Customer Presentation
In Situ Oxygen Transmitter For Combustion Monitoring
Head Mounted Temperature Transmitter
Magnetic flow meter for industrial process measurement
Module -1.pdf
Ad

More from Edress Hauser: Flow Meter, Level, Pressure, Temperature (20)

PDF
Liquiphant M Density and Density Computer FML621
PDF
Microwave barrier- Soliwave FQR56/FDR56
PDF
Microwave barrier-Soliwave M FQR50 / FDR50
PDF
Level Limit Switch-Soliswitch FTE31
PDF
Level limit switch-Soliswitch FTE30
PDF
Flow indicator for bulk solids-Solimotion FTR20
PDF
Level measurement with Prothermo NMT532
PDF
High accuracy liquid level measurement-Proservo NMS5
PDF
Conductive Limit Detection-Rod Probe 11263
PDF
Conductive-Point level switch for multiple point
PDF
Level limit switch compact design-Liquiphant T FTL20H
PDF
Vibronic-Point level switch for all kinds of liquids
PDF
Vibronic-Point level switch-Liquiphant M FTL51C
PDF
Level limit switch for liquids-Liquiphant T FTL20
PDF
Radiometric measuring technology-Gammapilot FTG20
PDF
Differential pressure measurement-Level transmiter
PDF
Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53
PDF
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
PDF
Capacitance level measurement-Liquicap M FMI51, FMI52
Liquiphant M Density and Density Computer FML621
Microwave barrier- Soliwave FQR56/FDR56
Microwave barrier-Soliwave M FQR50 / FDR50
Level Limit Switch-Soliswitch FTE31
Level limit switch-Soliswitch FTE30
Flow indicator for bulk solids-Solimotion FTR20
Level measurement with Prothermo NMT532
High accuracy liquid level measurement-Proservo NMS5
Conductive Limit Detection-Rod Probe 11263
Conductive-Point level switch for multiple point
Level limit switch compact design-Liquiphant T FTL20H
Vibronic-Point level switch for all kinds of liquids
Vibronic-Point level switch-Liquiphant M FTL51C
Level limit switch for liquids-Liquiphant T FTL20
Radiometric measuring technology-Gammapilot FTG20
Differential pressure measurement-Level transmiter
Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
Capacitance level measurement-Liquicap M FMI51, FMI52

Recently uploaded (20)

PPTX
Benefits of Physical activity for teenagers.pptx
PPTX
The various Industrial Revolutions .pptx
PDF
OpenACC and Open Hackathons Monthly Highlights July 2025
PDF
1 - Historical Antecedents, Social Consideration.pdf
PDF
Architecture types and enterprise applications.pdf
PDF
Two-dimensional Klein-Gordon and Sine-Gordon numerical solutions based on dee...
PDF
Getting started with AI Agents and Multi-Agent Systems
DOCX
search engine optimization ppt fir known well about this
PDF
CloudStack 4.21: First Look Webinar slides
PDF
Hybrid horned lizard optimization algorithm-aquila optimizer for DC motor
PDF
Credit Without Borders: AI and Financial Inclusion in Bangladesh
PDF
Enhancing emotion recognition model for a student engagement use case through...
PDF
Flame analysis and combustion estimation using large language and vision assi...
PDF
UiPath Agentic Automation session 1: RPA to Agents
PDF
A Late Bloomer's Guide to GenAI: Ethics, Bias, and Effective Prompting - Boha...
PDF
Zenith AI: Advanced Artificial Intelligence
PDF
Hindi spoken digit analysis for native and non-native speakers
PDF
The influence of sentiment analysis in enhancing early warning system model f...
PDF
Convolutional neural network based encoder-decoder for efficient real-time ob...
PDF
Taming the Chaos: How to Turn Unstructured Data into Decisions
Benefits of Physical activity for teenagers.pptx
The various Industrial Revolutions .pptx
OpenACC and Open Hackathons Monthly Highlights July 2025
1 - Historical Antecedents, Social Consideration.pdf
Architecture types and enterprise applications.pdf
Two-dimensional Klein-Gordon and Sine-Gordon numerical solutions based on dee...
Getting started with AI Agents and Multi-Agent Systems
search engine optimization ppt fir known well about this
CloudStack 4.21: First Look Webinar slides
Hybrid horned lizard optimization algorithm-aquila optimizer for DC motor
Credit Without Borders: AI and Financial Inclusion in Bangladesh
Enhancing emotion recognition model for a student engagement use case through...
Flame analysis and combustion estimation using large language and vision assi...
UiPath Agentic Automation session 1: RPA to Agents
A Late Bloomer's Guide to GenAI: Ethics, Bias, and Effective Prompting - Boha...
Zenith AI: Advanced Artificial Intelligence
Hindi spoken digit analysis for native and non-native speakers
The influence of sentiment analysis in enhancing early warning system model f...
Convolutional neural network based encoder-decoder for efficient real-time ob...
Taming the Chaos: How to Turn Unstructured Data into Decisions

Dissolved Oxygen Transmitter-Liquisys M COM223/253

  • 1. TI199C/07/EN/13.11 71130252 Technical Information Liquisys M COM223/253 Dissolved Oxygen Measurement Transmitter for oxygen sensors Application The modular design of the transmitter allows easy adaption to a variety of customer requirements. Starting with the basic version for "measurement and alarm generation", the transmitter can be equipped with additional software and hardware modules for special applications. These modules can also be retrofitted as required. Areas of Application • Sewage treatment plants • Wastewater treatment • Water treatment • Drinking water • Surface water: rivers, lakes, sea • Fish farming • Boiler feed water (trace measurement) Your benefits • Field or panel-mounted housing • Universal application • For analogue and digital sensors • Simple handling – Logically arranged menu structure – Simple single-point calibration in air, air-saturated water or in the medium is possible • Safe operation – Excellent interference immunity – Direct access for manual contact control – User-defined alarm configuration The basic unit can be extended with: • 2 or 4 additional contacts for use as: – Limit contacts (also for temperature) – P(ID) controller – Timer for simple rinse processes – Complete cleaning with Chemoclean • Plus package: – User-defined current output characteristics – Automatic cleaning trigger on alarm or limit violation – Process monitoring – Sensor live check • HART or PROFIBUS-PA/-DP • 2nd current output for temperature, main measured value or actuating variable • Current input for flow rate monitoring with controller shut off or for feedforward control
  • 2. Liquisys M COM2x3 2 Endress+Hauser Function and system design Features of the basic version Measurement of oxygen content and of partial oxygen pressure The oxygen content is displayed in mg/l or in %SAT, the partial oxygen pressure is displayed in hPa. This is selected via the menu. The temperature is displayed at the same time or, if desired, not shown at all. Calibration The amperometric sensors are zero-current-free and only require a single-point calibration. This takes place in air, air-saturated water or by reference calibration in the medium. The optical sensor will be calibrated before shipment. If necessary it can be calibrated in air and for zero point. Configuration Different alarms are required depending on application and operator. Therefore the transmitter permits independent configuration of the alarm contact and error current for each individual error. Unnecessary or undesirable alarms can be suppressed in this manner. Up to four contacts can be used as limit contacts (also for temperature), to implement a P(ID) controller or for cleaning functions. Direct manual operation of the contacts (bypassing the menu) provides quick access to limit, control or cleaning contacts, permitting speedy correction of deviations. The serial numbers of the instrument and modules and the order code can be called up on the display. Additional functions of version WX/WS/DS Automatic pressure compensation Oxygen concentration is not only dependent on altitude but also on weather conditions (pressure). Automatic pressure compensation takes these fluctuations into account. Additional functions of the Plus package Current output configuration In order to output wide measuring ranges while still achieving a high resolution in specific ranges, the current output can be configured as required via a table. This permits bilinear or quasi-logarithmic curves, etc. Process Check System (PCS) It comprises two independent safety functions: • Errors in applications without control are detected by monitoring the limit beween plausible and implausible measured values, i.e. the alarm theshold. • Errors in applications with control are detected by the controller monitor which monitors freely adjustable, maximum permissible time intervals and reference value overshoot or undershoot. Live check, sensor activity monitoring The live check issues an alarm when the sensor signal does not change over a defined period of time. This may be caused by blocking, passivation, separation from the process, etc. Second current output The second current output can be configured for temperature, main measured value (oxygen content, partial oxygen pressure) or actuating variable. Current input The current input of the transmitter allows two different applications: controller shut-down in case of lower flow rate violation or total failure in the main flow as well as feedforward control. Both functions are also combinable.
  • 3. Liquisys M COM2x3 Endress+Hauser 3 Measuring system A complete measuring system comprises: Variant 1 (DX/DS with COS41) • The transmitter Liquisys M COM223 or COM253 in version DX or DS • An oxygen sensor COS41 • An immersion, flow or retractable assembly Options: extension cable CMK, junction box VBM Variant 2 (WX/WS with COS31, COS61 or COS71) • The transmitter Liquisys M COM223 or COM253 in version WX or WS • An oxygen sensor COS31, COS61 or COS71 • An immersion, flow or retractable assembly Options: extension cable OMK, junction box VS C07-COM2x3xx-14-06-00-xx-002.eps Complete measuring system Liquisys M COM223/253 1 2 3 4 Oxygen sensor Immersion assembly CYA112 Holder CYH112 Weather protection cover CYY101 5 6 7 Liquisys M COM253 Liquisys M COM223 Retractable assembly COA451 CAL REL REL1 REL1 ALARM REL2 REL2E CAL REL REL1 REL1 ALARM REL2 REL2E 1 2 3 5 67 4
  • 4. Liquisys M COM2x3 4 Endress+Hauser Input Measured variables Oxygen Temperature Measuring range Cable specification O2 signal input Binary inputs Current input 4 to 20 mA, galvanically separated Load: 260 Ω at 20 mA (voltage drop 5.2 V) Output Output signal 0/4 to 20 mA, galvanically separated, active COS31: Oxygen concentration 0 ... 20 / 0 ... 60 mg/l Oxygen saturation index 0 ... 200 / 0 ... 600 % SAT Oxygen partial pressure 0 ... 400 / 0 ... 1200 hPa COS41, COS61: Oxygen concentration 0 ... 20 mg/l Oxygen saturation index 0 ... 200 % SAT Oxygen partial pressure 0 ... 400 hPa COS71: Oxygen concentration 0 ... 20 mg/l Oxygen saturation index 0 ... 200 % SAT Oxygen partial pressure 0 ... 400 hPa Temperature: -10 ... 60 °C (14 ... 140 °F) Cable length: COS31, COS61, COS71 max. 100 m (328 ft) COS41 max. 50 m (164 ft) Version DX/DS: 0 ... 3000 nA Version WX/WS: digital communication or 0 ... -7500 mV Voltage: 10 to 50 V Power consumption: max. 10 mA HART Signal coding Frequency Shift Keying (FSK) + 0.5 mA via current output signal Data transfer rate 1200 Baud Galvanic isolation yes PROFIBUS PA Signal coding Manchester Bus Powered (MBP) Data transfer rate 31.25 kBit/s, voltage mode Galvanic isolation yes (IO-Module) PROFIBUS DP Signal coding RS485 Data transfer rate 9.6 kBd, 19.2 kBd, 93.75 kBd, 187.5 kBd, 500 kBd, 1.5 MBd Galvanic isolation yes (IO-Module)
  • 5. Liquisys M COM2x3 Endress+Hauser 5 Signal on alarm 2.4 or 22 mA in case of an error Load maximum 500 Ω Transmission range Resolution max. 700 digits/mA Isolation voltage max. 350 VRMS/500 V DC Overvoltage protection according to EN 61000-4-5 Auxiliary voltage output Contact outputs Limit contactor Controller Alarm COS31: Oxygen concentration Δ 0.2 ... Δ 20 / Δ 0.6 ... Δ 60 mg/l Oxygen saturation index Δ 2 ... Δ 200 / Δ 6 ... Δ 600 % SAT Oxygen partial pressure Δ 4 .... Δ 400 / Δ 12 ... Δ 1200 hPa COS41, COS61: Oxygen concentration Δ 0.2 ... Δ 20 mg/l Oxygen saturation index Δ 2 ... Δ 200 % SAT Oxygen partial pressure Δ 4 .... Δ 400 hPa COS71: Oxygen concentration Δ 0.02 ... Δ 20 mg/l Oxygen saturation index Δ 0.2 ... Δ 200 % SAT Oxygen partial pressure Δ 0.4 .... Δ 400 hPa Temperature: Δ 7 ... Δ 70 °C Output voltage: 15 V ± 0.6 Output current: max. 10 mA Switching current with ohmic load (cos ϕ = 1): max. 2 A Switching current with inductive load (cos ϕ = 0.4): max. 2 A Switching voltage: max. 250 V AC, 30 V DC Switching power with ohmic load (cos ϕ = 1): max. 500 VA AC, 60 W DC Switching power with inductive load (cos ϕ = 0.4): max. 500 VA AC, 60 W DC Pickup/dropout delay: 0 to 2000 s Function (adjustable): pulse length/pulse frequency controller Controller response: PID Control gain Kp: 0.01 to 20.00 Integral action time Tn: 0.0 to 999.9 min Derivative action time Tv: 0.0 to 999.9 min Period for pulse length controller: 0.5 to 999.9 s Frequency for pulse frequency controller: 60 to 180 min-1 Basic load: 0 to 40% of max. set value Function (switchable): latching/momentary contact Alarm threshold adjustment range: O2 / temperature: entire measuring range, depending on sensor type Alarm delay: 0 ... 2000 s (min) Monitoring time lower limit violation: 0 ... 2000 min Monitoring time upper limit violation: 0 ... 2000 min
  • 6. Liquisys M COM2x3 6 Endress+Hauser Protocol specific data HART Manufacturer ID 11h Device type code 0094h Transmitter specific revision 0001h HART specification 5.0 DD files www.products.endress.com/profibus Load HART 250 Ω Device variables None (dynamic variables PV, SV, only) Features supported - PROFIBUS PA Manufacturer ID 11h Ident number 1518h Device revision 11h Profile version 2.0 GSD files www.products.endress.com/profibus GSD file version Output values Main value, temperature value Input values Display value of PLC Features supported Device locking: The device can be locked by hardware or software. PROFIBUS DP Manufacturer ID 11h Ident number 151Eh Profile version 2.0 GSD files www.products.endress.com/profibus GSD file version Output values Main value, temperature value Input values Display value of PLC Features supported Device locking: The device can be locked by hardware or software.
  • 7. Liquisys M COM2x3 Endress+Hauser 7 Power supply Electrical connection COM2x3-DX/DS The device is approved for protection class II and is generally operated without a protective earth connection. a0015422 Electrical connection version DX or DS A B C D E F * Sensor COS41 Signal output 1 oxygen Signal output 2 temperature Binary input 1 (Hold) Binary input 2 (Chemoclean) Aux. voltage output Aux. voltage output terminal 85/86 applicable G H I J K L M Alarm (current-free contact position) Relay 1 (current-free contact position) Relay 2 (current-free contact position) Relay 3 (current-free contact position) Relay 4 (current-free contact position) Current input 4 ... 20 mA Power supply
  • 8. Liquisys M COM2x3 8 Endress+Hauser Electrical connection COM2x3-WX/WS1) The device is approved for protection class II and is generally operated without a protective earth connection. Note! The signals "Sensor signal" and "Alarm" are not used by COS61 and the TOP68-versions. 1) COS61 sensors from serial no. 79xxxx C07-COM2x3xx-04-06-00-xx-003.eps Electrical connection version WX/WS A B C D E F G H * Oxygen sensor COS31/61/71 Junction box VS with extension COM253: Plug connection for oxygen sensor COM223: The sensor cable plug must be removed or junction box VS used Signal output 1 oxygen Signal output 2 temperature Binary input 1 (Hold) Binary input 2 (Chemoclean) Aux. voltage output Aux. voltage output terminal 85/86 applicable I J K L M N O Alarm (current-free contact position) Relay 1 (current-free contact position) Relay 2 (current-free contact position) Relay 3 (current-free contact position) Relay 4 (current-free contact position) Current input 4 ... 20 mA Power supply 47 48 49 57 58 59 41 42 43 15 V 85 86 10-50 V 81 93 82 94 10-50 V mA 31 32 mA 33 34 51 52 53 54 55 56 18 96 97 19 S O2 O2 GN PK BU 8,5 V DC 88 0 87 + 0 - 8,5 V DC WH BN GY YE1 2 5 4 3 7 6GN PK BU WH BN GY YE RS 485 23 + 24 - mA L+ L–N L1 ~ = A B C D E F G H I J K L M N O * * B A
  • 9. Liquisys M COM2x3 Endress+Hauser 9 Sensor cable The oxygen sensors are supplied with the measuring cable. To extend this cable, you have to use a junction box and an extension cable (see "Accessories"). Supply voltage Depending on ordered version: 100/115/230 V AC +10/-15 %, 48 to 62 Hz 24 V AC/DC +20/-15 % Fieldbus connection Power consumption max. 7.5 VA Mains protection Fine-wire fuse, medium-slow blow 250 V/3.15 A a0015423 COS41 to COM2x3-DX/DS with CYK71 cable a0015424 COS31/611) /71 to COM2x3-WX/WS 1) from serial no. 79xxxx HART Supply voltage n/a, active current outputs Integrated reverse voltage protection n/a, active current outputs PROFIBUS PA Supply voltage 9 V to 32 V, max. 35 V Polarity sensitive no FISCO/FNICO compliant acc. to IEC 60079-27 no PROFIBUS DP Supply voltage 9 V to 32 V, max. 35 V Polarity sensitive n/a FISCO/FNICO compliant acc. to IEC 60079-27 no
  • 10. Liquisys M COM2x3 10 Endress+Hauser Performance characteristics Resolution Maximum measured error2) Repeatabilitya max. 0.2 % of measuring range Temperature compensation range 0 ... 50 °C (32 ... 104 °F) Pressure compensation range 500 ... 1100 hPa Altitude adjustment range 0 ... 4000 m (0 ... 13124 ft) Salinity adjustment range 0 ... 4 % Slope adjustment range Oxygen: COS31, COS41, COS61: 0.01 mg/l / 0.1 % SAT / 1 hPa COS71: 0.001 mg/l / 0.1 % SAT / 1 hPa Temperature: 0.1 °C 2) acc. to IEC 746-1, for nominal operating conditions Display Oxygen: max. 0.5 % of measuring range Temperature: max. 1.0 % of measuring range Signal output Oxygen: max. 0.75 % of measuring range Temperature: max. 1.25 % of measuring range COS31: 75 ... 140 % (nominal 290 nA, in air, 20 °C (68 °F), 1013 hPa) COS41: 75 ... 140 % (nominal 290 nA, in air, 20 °C (68 °F), 1013 hPa) COS61: 75 ... 140 % (nominal 1340 nA, in air, 20 °C (68 °F), 1013 hPa) COS71: 50 ... 150 % (nominal 8000 nA, in air, 20 °C (68 °F), 1013 hPa)
  • 11. Liquisys M COM2x3 Endress+Hauser 11 Installation Installation instructions a0005733 Field instrument a0005737 Mounting on pipes 1 - 3 Mounting screws and mounting plate CAL REL REL1 REL1 ALARM REL2 REL2E Pg 7 Pg 16 M5 11/ 0.43 Ø6/ Ø0.24 115 / 4.53 157/6.18 247/9.72 70/2.76 70 / 2.76 154 / 6.06 170 / 6.69 mm / inch Pg 13.5 1 2 3 1 1 3 Ømax.60/ 2.36 mm / inch
  • 12. Liquisys M COM2x3 12 Endress+Hauser a0005734 View into the field instrument 1 2 3 4 Removable electronics box Partition plate Terminal blocks Fuse a0005736 Wall mounting of the field instrument 1 Mounting holes 2 Protecting cap a0005738 Mounting of the field instrument with mounting post and weather protection cover 1 - 3 Mounting holes 1 2 3 4 1 2 154 / 6.06 mm / inch Ø6/ Ø0.24 3 1 2 3
  • 13. Liquisys M COM2x3 Endress+Hauser 13 a0005735 Dimensions panel-mounted instrument a0005739 Installation of the panel-mounted instrument 1 Wall of control cabinet 2 Gasket 3 Tensioning screws * Required installation depth 90 / 3.54 139/5.47 96/3.78 6 / 0.24 mm / inch 92 / 3.62 149.5/5.89 1 2 3 3 3 92 / 3.62+0.5 +0.02 92/3.62 +0.5+0.02 90/3.54 57/2.24 33/ 1.30 approx. 25 / 0.98 139 / 5.47 max. 45 / 1.77 6 / 0.24 96/3.78 92/ 3.62 approx. 165 / 6.50* mm / inch
  • 14. Liquisys M COM2x3 14 Endress+Hauser Environment Ambient temperature -10 to +55 °C (+14 to +131 °F) Storage temperature –25 to +65 °C (-13 to +149 °F) Electromagnetic compatibility Interference emission and interference immunity as per EN 61326-1:2006, EN 61326-2-3:2006 Ingress protection Electrical safety according EN/IEC 61010-1:2001, Installation Category II, for use up to 2000 m above sea level CSA Apparatus with CSA General Purpose Approval are certified for indoor use. Relative humidity 10 to 95%, non-condensing Pollution degree The product is suitable for pollution degree 2. Mechanical construction Dimensions Weight Materials Terminals Panel mounted instrument: IP 54 (front), IP 30 (housing) Field instrument: IP 65 / tightness acc. to NEMA 4X Panel mounted instrument: 96 x 96 x 145 mm (3.78 x 3.78 x 5.71 inches) Installation depth: approx. 165 mm (6.50") Field instrument: 247 x 170 x 115 mm (9.72 x 6.69 x 4.53 inches) Panel mounted instrument: max. 0.7 kg (1.5 lb) Field instrument: max. 2.3 kg (5.1 lb) Housing of panel mounted instrument: Polycarbonate Field housing: ABS PC Fr Front membrane: Polyester, UV-resistant Cross section max. 2.5 mm2
  • 15. Liquisys M COM2x3 Endress+Hauser 15 Operability Operating concept All instrument control functions are arranged in a logical menu structure. Following access code entry, the individual parameters can be easily selected and modified as needed. Display elements C07-COM2x3xx-19-06-00-en-001.eps Operating elements The display simultaneously shows the current measured value and the temperature - the essential process data. Brief information texts in the configuration menu provide assistance with parameter configuration. Certificates and approvals 4 symbol Declaration of conformity The product meets the requirements of the harmonized European standards. It thus complies with the legal requirements of the EC directives. The manufacturer confirms successful testing of the product by affixing the 4 symbol. CSA General purpose C.M2.3-..2... C.M2.3-..3... C.M2.3-..7... 1.85 mg/l R232 1 2 3 4 5 6 7 Setpoint
  • 16. Liquisys M COM2x3 16 Endress+Hauser Ordering information Product structure Additional functions of the Plus package • Current output table to cover large areas with varying resolution, fields O23x • Process Check System (PCS): live check of the sensor, function group P • Automatic cleaning function start, field F8 • At version DS: air pressure measurement Scope of delivery The delivery of the field instrument includes: • 1 transmitter COM253 • 1 plug-in screw terminal • 1 cable gland Pg 7 • 1 cable gland Pg 16 reduced • 2 cable glands Pg 13.5 • 1 Operating Instructions BA199C/07/EN • versions with HART communication: 1 Operating Instructions Field Communication with HART, BA208C/07/EN • versions with PROFIBUS communication: 1 Operating Instructions Field Communication with PROFIBUS PA/DP, BA209C/07/EN The delivery of the panel mounted instrument includes: • 1 transmitter COM223 • 1 set of plug-in screw terminals • 2 tensioning screws • 1 BNC-plug (solder-free) • 1 Operating Instructions BA199C/07/EN • versions with HART communication: 1 Operating Instructions Field Communication with HART, BA208C/07/EN • versions with PROFIBUS communication: 1 Operating Instructions Field Communication with PROFIBUS PA/DP, BA209C/07/EN Input, software version DX Sensor COS41 / 4 / 4HD, basic functions DS Sensor COS41 / 4 / 4HD, with additional functions (Plus package) WX Sensor COS31 / 61 / 71 / 3 / 3HD, basic functions WS Sensor COS31 / 61 / 71 / 3 / 3HD, with additional functions (Plus package) Power supply, approval 0 230 V AC 1 115 V AC 2 230 V AC; CSA Gen. Purp. 3 115 V AC; CSA Gen. Purp. 5 100 V AC 7 24 V AC/DC; CSA Gen. Purp. 8 24 V AC/DC Output 0 1 x 20 mA, primary value 1 2 x 20 mA, primary value + secondary value 3 PROFIBUS PA 4 PROFIBUS DP 5 1 x 20 mA, primary value, HART 6 2 x 20 mA, primary value, HART + secondary value Additional contacts 05 not selected 10 2 relays (limit/P(ID)/timer) 15 4 relays (limit/P(ID)/Chemoclean) (not with PROFIBUS DP) 16 4 relays (limit/P(ID)/timer) (not with PROFIBUS DP) 20 1 x 4 ... 20 mA input + 2 relays (limit/P(ID)/timer) 25 1 x 4 ... 20 mA input + 4 relays (limit/P(ID)/Chemoclean) (not with PROFIBUS DP) 26 1 x 4 ... 20 mA input + 4 relays (limit/P(ID)/timer) (not with PROFIBUS DP) Marking 1 Tagging (Tag), see additional spec. COM253- complete order code COM223-
  • 17. Liquisys M COM2x3 Endress+Hauser 17 Accessories Sensors Oxymax W COS31 • Oxygen sensor for drinking water and wastewater measurements, potentiostatic amperometric principle • Material: stainless steel 1.4571 (AISI 316 Ti) • Ordering acc. to product structure, see Technical Information TI285C/07/EN Oxymax W COS41 • Oxygen sensor for drinking water and wastewater measurements, amperometric principle • Material: POM • Ordering acc. to product structure, see Technical Information TI284C/07/EN Oxymax W COS71 • Oxygen sensor for trace measurement, potentiostatic amperometric principle • Material: stainless steel 1.4571 (AISI 316 Ti) • Ordering acc. to product structure, see Technical Information TI286/07/EN Oxymax W COS61 • Optical oxygen sensor for drinking water and wastewater measurements, fluorescence quenching principle • Material: stainless steel 1.4571 (AISI 316 Ti) • Ordering acc. to product structure, see Technical Information TI387C/07/EN Connection accessories OMK measuring cable • non-terminated measuring cable for oxygen sensors COS31, COS61 and COS71, for extension between junction box VS and transmitter • Sold by the meter, order no. 50004124 CMK measuring cable • non-terminated measuring cable for oxygen sensor COS41, for extension between junction box VBM and transmitter • Sold by the meter, order no. 50005374 VS junction box • With plug-in socket and 7-pole plug • For cable extension from sensor (COS71, COS61, COS31, COS3 with SXP connector) to transmitter, IP 65; • Order no. 50001054 Junction box VBM • for cable extension for sensors COS41, COS4 (fixed cable versions) • with 10 terminals, IP 65 / NEMA 4X • Order numbers: – Cable entry Pg 13.5: 50003987 – Cable entry NPT ½": 51500177
  • 18. Liquisys M COM2x3 18 Endress+Hauser Mounting accessories CYY101 weather protection cover for field devices, absolutely essential if operating the unit outdoors • Material: stainless steel 1.4031 (AISI 304) • Order No. CYY101-A Post mounting kit • For mounting of field housing on horizontal or vertical pipes (Ø max. 60 mm (2.36")) • Material: stainless steel 1.4301 • order no. 50086842 a0005676 Post mounting kit a0012427 Weather protection cover for field devices * Wall and post mounting ** Rail mounting 70 / 2.76 90 / 3.54 Ø 6 / 0.24 Ø8/ 0.31 70/2.76 90/3.54 M6 60/2.36 90 / 3.54 70 / 2.76 Ø8/ 0.31 30/ 1.18 Ø max. 60 / 2.36 mm / inch
  • 19. Liquisys M COM2x3 Endress+Hauser 19 CYY102 universal post • Square pipe for mounting transmitters • Material: stainless steel 1.4301 (AISI 304) • Order No. CYY102-A a0005742 Universal post Optoscope Optoscope • Interface between transmitter and PC / laptop for service purposes. • The Windows software "Scopeware" required for the PC or laptop is supplied with the Optoscope. The Optoscope is supplied in a sturdy plastic case with all the accessories required. • Order no. 51500650 1495/58.86 60 x 60 / 2.36 x 2.36 120 / 4.72 150/ 5.91 mm/inch