SlideShare a Scribd company logo
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 –
6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME
209
DSTATCOM BASED VOLTAGE REGULATOR FOR WIND TURBINE
DRIVEN SELF-EXCITED INDUCTION GENERATOR
Dr. RAJSEH KUMAR AHUJA, PRIYANKA PHAGERIA
YMCA University of Science & Technology, Faridabad
ABSTRACT
Voltage sag is the most important powerquality problems faced by many industries
and utilities.This paper presents the voltage sag mitigation usingDSTATCOM (Distribution
Static Compensator).DSTATCOM is used for reactive power compensation. This paper
presents an analysis of the three-phaseself-excited induction generator (SEIG) with
DSTATCOM as a voltage regulator , which provides fast dynamic response tomaintain
constant voltage at SEIG terminals during severeload perturbations and acts as a source and
sink of reactivepower.Thispaper evaluates vector control algorithm forextracting reference
source currents for voltage regulationat PCC (Point of Common Coupling) for DSTATCOM.
Thevoltage source converter (VSC) is used with DC linkcapacitor as a DSTATCOM.
1. INTRODUCTION
Power Quality problem such as Voltage sag is the most important power quality
problems faced by many industries and utilities. It contributes more than 80% power quality
(PQ) problems that exist in power systems. The majority of power consumption has been
drawn in reactive loads.These excessive reactive power demandincreases feeder losses and
reduces the active power flow capability of distribution system which also affects thevoltage
profile. The reason for this is the majority of loads in the distribution systems are linear
laggingpower factor and nonlinear, balanced and unbalanced loads. Such power quality
problems can be mitigatedby the DSTATCOM (Distribution Static Synchronous
Compensator) at the point of common coupling (PCC). Induction Generators used in stand-
alone as well as grid connected system as recent development has done in pollution free
power generation schemes.When a capacitor bank is connected across the Induction
INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING
& TECHNOLOGY (IJEET)
ISSN 0976 – 6545(Print)
ISSN 0976 – 6553(Online)
Volume 4, Issue 3, May - June (2013), pp. 209-219
© IAEME: www.iaeme.com/ijeet.asp
Journal Impact Factor (2013): 5.5028 (Calculated by GISI)
www.jifactor.com
IJEET
© I A E M E
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 –
6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME
210
Generator then it Known as a Self-Excited Induction generator. It is well known that when
capacitors are connectedacross the stator terminals of an induction machine,driven by an
external prime mover, voltage will beinduced at its terminals . The induced emf andcurrent in
the stator windings will continue to rise untilsteady state is attained, it means reactive power
supplied by capacitor bank is balanced by reactive power absorbed by load. In order for self-
excitationto occur, for a particular capacitance value there is acorresponding minimum speed.
The self-excited induction generator (SEIG) has some advantages over the synchronous
generator, for example:brushless (squirrel-cage rotor), reduced size, rugged and low cost.
However, the induction generator offers poor voltage regulation and its value depends on the
prime mover speed,capacitor bank size and load characteristics. The generated voltage of the
SEIG is mainly depends upon the excitation capacitance values, change in wind velocity and
load conditions. The reactive power requirementby the induction generator can also be
supplied by a group of capacitors. If the capacitance is insufficient,the induction generators
will not build up voltage. The main drawback of the induction generator is need ofreactive to
build up the terminal voltage. In the SEIG, the excitation current is supplied by the capacitors
connected across its terminals. Self-excited induction generators are good candidates for wind
powered electric generation application especially in remote areas, because they do not need
external power supply to produce the magnetic field.
By using the DSTATCOM the voltage across the SEIG remains constant at varying
loads.Thesimulated results demonstrate the use of DSTATCOM as a voltage regulator across
a SEIG network.
2. CONTROL SCHEME
When used in low voltage distribution system, thestatic compensator (STATCOM) is
identified asDistribution STATCOM (DSTATCOM). In generalDSTATCOM is used to
generate or absorb reactivepower.The D-STATCOM is a three-phase and shunt connected
power electronics based device.
When a DSTATCOM is connected across the SEIG then the additional demand
ofreactive power is fulfilled by the DSTATCOM under varyingloads. The DSTATCOM acts
as a source of lagging or leadingcurrents to maintain the terminal voltage constant with
variation in load.The DSTATCOM consists of a three-phaseIGBT (Insulated gate bipolar
transistor) based currentcontrolled voltage source inverter, DC bus capacitor and
ACinductors. The AC output of the inverter is connectedthrough the AC filtering inductor to
the SEIG terminals.The DC bus capacitor is used as an energy storage deviceand provides
self-supporting DC bus.
The control technique to regulate the terminal voltage of theSEIG is based on the
control of source currents (having twocomponents one in-phase and other quadrature). PLL is
used to generate the sin(wt) and cos(wt). The two measurement systems(Vmeas and Imeas)
blocks compute the d-axis and q-axis components of the voltages and currents by executing
an abc-dq transformation in the synchronous reference determined by sin(wt) and cos(wt)
provided by the PLL,this block calculate the mag V and IdIq current.
TheAC terminal voltage (V) is compared with the reference voltage. The voltage error
is processed in the PI controller. The output of the PI controller (lq ref) for AC voltage
control loop decides the amplitude of reactive current required for the system.The DC bus
voltage of the STATCOM is sensed and compared with DC reference voltage. The error
voltage is processed in another PI controller. The output of this PI controller (Id ref) decides
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 –
6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME
211
the amplitude of active current, which is required by DSTATCOM to maintain constant DC
bus voltage. The quadrature and in-phase components is thesource reference current, which is
compared with the SEIG line current. The error current is processed in PID controller.The
output of this PID controller maintains the primary voltage equal to the reference value. This
VqVd is further used to generate reference voltage for Voltage source converter.
3. MATHEMATICAL MODELLING
Modelling of SEIG
The dynamic model of the three-phase SEIG is developedusing stationary d-q axes
references frame is used because it provides a complete solution for dynamic analysis and
control.
The flux linkages per second taken into account the saturation effect are
Circuit for q axis and q axis of IG
Vqs=rsiqs+ωφds+d/dt(φqs)
Vds=rsids-ωφqs+d/dt(φds)
V’qr = r’ri’qr + (ω - ωr )φ’dr +d/dt(φ’qr)
V’dr= r’ri’dr - (ω - ωr )φ’qr +d/dt(φ’dr)
φqs = Llsiqs + Lm (iqs + i'qr)
φds = Llsids + Lm (ids + i'dr)
φ’qr = L’lriqr + Lm (iqs + i'qr)
φ’dr = L’lri’dr + Lm (ids + i'dr)
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 –
6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME
212
In the above equations, all the rotor variables are referredto the stator side. The
expression for the electromagnetic Torque of the SEIG is expressed as in per (unit can be
written as:)
Te=(3/2)(p/2)Lm(φdsiqs- φdsids)
The electromagnetic torque balance equation of SEIG isdefined as
Tshaft = TB + J(2/P)p(ωr)
The derivative of rotor speed of the SEIG-
pωr={P/(2J)}(Tshaft-Te)
Modelling of wind turbine
The wind turbine is characterized by no dimensional curves of the power coefficient
Cp as a function of both the tip speed ratio, ë and the blade pitch angle, Â. In order to fully
utilize the available wind energy, the value of ë should be maintained at its optimum value.
Therefore, the power coefficient corresponding to that value will become maximum.
The output power of the wind turbine, can be calculated from the following equation
Pm=.5AρCp(λ,β)V3
wind
where
Pm=Mechanical output power of the turbine (W)
Cp=Performance coefficient of the turbine
Ρ=Air density (kg/m3)
A=Turbine swept area (m2)
Vwind=Wind speed (m/s)
λ =Tip speed ratio of the rotor blade tip speed to wind speed
β=Blade pitch angle (deg)
Pm can be normalized. In the per unit (pu) system we have:-
Pm_pu=.5AρCp_pu(λ,β)V3
wind_pu
generic equation is used to model cp(λ,β). This equation, based on the modelling turbine
characteristics of [1], is:-
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 –
6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME
213
The non-linear, dimensionless Cpcharacteristic is represented as .:-
Cp(λ,β)=C1(C2/ λi-C3 β-C4)e-(C5/ λi)+
C6λi
With
(1/λi)=(1/( λ+0.08 β))-(0.035/( β3
+1))
where,
C1 = 0.5176, C2 = 116, C3 = 0.4, C4 = 5, C5 = 21, C6 = 0.0068
Modelling of DSTATCOM
Three-phase voltages at the SEIG terminals (va, vb and vc) are considered
Convert this sinusoidal voltage into dq0.
Vd = 2/3*[Va*sin(wt) + Vb*sin(wt-2pi/3) + Vc*sin(wt+2pi/3)]
Vq = 2/3*[Va*cos(wt) + Vb*cos(wt-2pi/3) + Vc*cos(wt+2pi/3)]
V0 = 1/3*[Va + Vb + Vc ]
Amplitude is:-
V=√(Vd2
+Vq2
)
Three phase current at the SEIG terminals(Ia,Ib,Ic) are considered.and convert this current
into Id Iq I0.
Id = 2/3*[Ia*sin(wt) + Ib*sin(wt-2pi/3) + Ic*sin(wt+2pi/3)]
Iq = 2/3*[Ia*cos(wt) + Ib*cos(wt-2pi/3) + Ic*cos(wt+2pi/3)]
I0 = 1/3*[Ia + Ib + Ic ]
The active power component of the source current isId* which is required for the self
supporting DC bus ofDSTATCOM. Moreover, the reactive component isIq* which is
required for maintaining the amplitude of the PCC voltage. The active component of the load
currentId* can be expressed as:-
I* q = kpVdce+ki∫Vdcedt
Vdce=Vdc*-Vdc
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 –
6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME
214
Vdce error in DC bus voltage.Vdc*and Vdc are the reference voltage and sensed filteredvoltage
of DC bus of DSTATCOM respectively. Kp and Ki are the proportional and integral gains of
the PI controller over the DC bus voltage of DSTATCOM.
I*d=kpVte+ki∫Vtedt
Vte=V*t-Vt
Vte=error in amplitude of the PCCvoltage. Vt* and Vt are reference voltage and amplitude of
PCC voltage respectively. Kpand Ki are proportional and integral gains of the PI controller
over the PCCvoltage.
Now this I*d I*q is compared with Id Iq and the error signal is given to the controller and the
output of controller iusVdVq.
Vd=KpIde+Ki∫Idedt+Kd(d/dt)Ide
Where Ide=Id-I*d
Vq=kpIqe+ki∫Iqedt+kd(d/dt)Iqe
Where Iqe=Iq-I*q
This VqVd is further used to generate reference voltage for Voltage source converter.
4. SIMULATION RESULTS AND DISCUSSION
Simulations have been carried out for a 7.5kW threephase- SEIG with balanced,
unbalanced resistive and reactive at 0.8 PF and nonlinear load. Disconnecting one or two
phases of loads from the SEIG has created unbalanced conditions.
The DC bus voltage of DSTATCOM is selected 700V for the source line voltage of
400 V.
The VSC is connected to the network through the AC inductor of 800mH. For self-
supporting DC bus of DSTATCOM, a capacitor of 6000µF is used. Initially considered linear
reactive load is 3-single phase load.The PCC line voltage is considered 700 V,The simulation
results are taken for the above mentioned load conditions.
A. Performance of DSTATCOM with and Without in Balanced load condition
The SEIG system under balanced load without connecting the FACT device i.e.
DSTATCOM. Here asynchronous machine driven by wind turbine is connected across the
various balanced loads. This asynchronous machine is converted into SEIG by connecting a
capacitor bank.The balanced loads consist of two reactive loads (0.8 lagging) and one
resistive load. The first reactive load is applied at the starting of the simulation, the second
reactive load comes at 2 seconds after starting and the resistive load comes after 2.5 seconds.
Fig. 1 (a), (b) & (c) shows the variations in load voltage, load current and stator
current with respect to variations in applied load and wind speed. It is depicted that at instant
2 sec. as load increases from 7A to 9A the load voltage falls to 290V from 470V. Further at
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 –
6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME
215
instant 2.5 sec as load increases to 10A the load voltage falls to 300V from 340V. It is also
clear that the voltage and currents are also changing with the variations in wind speeds. The
load voltage drops marginally from 500V to 470V when wind speed changes from 12m/s to
10m/s at instant 1.95 sec. At 2.2 sec. the wind speed increases to 11m/s resulting in increase
in load voltage to 340V from 290V. There are also marginal variations observed in load
current and stator current. This shows that the Voltage across the SEIG not constant, so to
maintain voltage constant across the SEIG DSTATCOM is connected.
Fig. 1 (a) Load Voltage, (b) Load Current, (c) Stator Current and (d) Wind Speed
Now, The DSTATCOM is connecting across the SEIG to improve the Voltage profile.
By comparing the results of with and without DSTATCOM on SEIG system in has
observed that the DSTATCOM maintains the voltage profile of load voltage as constant
irrespective of changes in load and wind speed. The DSTATCOM injects sufficient reactive
power into the system so as to maintain the load voltage constant. It has also observed that
the profile of stator current has also got improved. When the load is increased across the
generator then the reactive power is shared by IG and load so the IG needs some reactive
power to maintain the voltage constant.
This Reactive power demand fulfil by connecting the DSTATCOM across the
generator.
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 –
6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME
216
Fig. 2 (a) load voltage, (b) load current, (c) stator current and (d) wind speed
B. Performance of DSTATCOM with and without in non-linear load condition
Now connect a non-linear load across the SEIG system without connecting the FACT device
i.e. DSTATCOM
Fig. 3 (a) load voltage, (b) load current, (c) stator current and (d) wind speed
The non-linear load injects the harmonics in system and distorts the currents &
voltages and also de-rates the machine.
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 –
6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME
217
In Fig. 3 when wind speed is change the voltage across the IG is changes respectively
and when load is increased across the IG the voltage is decreased.to make the voltage profile
constant a FACTS device is connected across the SEIG.A FACTS device DSTATCOM is
connected across the SEIG to improve the voltage profile of the system and also remove the
harmonics in system
By comparing the results of the effect of non-linear load on SEIG system after the
inclusion of DSTATCOM it has observed that it not only fulfils the reactive power demand
of the system but also minimises the harmonics in the system. It is clear from Fig. 4 that the
effects of non-linearity on load voltage and stator current are considerably reduced.
.
Fig. 4 (a) load voltage, (b) load current, (c) stator current and (d) wind speed
In this way DSTATCOM also restores the rating of the machine which has reduced due to the
effects of harmonics.
THD of non-linear load in system without DSTATCOM
THD for Stator voltage = 42.18%
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 –
6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME
218
THD for stator current = 71.34%
THD of non-linear load in system with DSTATCOM
THD for Stator voltage = 9.39%
THD for stator current = 6.98%
International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 –
6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME
219
5. CONCLUSION
A mathematical model of three-phase self-excited induction generator with
DSTATCOM based voltage regulator under balanced/unbalanced/non-linear loads is studied
in this project. It is concluded from the simulated results that the DSTATCOM acts as an
ideal voltage regulator and load balancing device, which maintains the SEIG voltage constant
and balances the SEIG system at varying balanced, unbalanced and non-linear loads
APPENDIX A
Parameters of machine
Rated power 10 HP(7.5 KW)
Voltage 400V
Frequency 50HZ
RPM 1440
Capacitor Bank 7.5 KVAR
Parameters of wind turbine
Nominal power 7650W
Base power 7650(VA)
Base speed 10
Max power at base wind speed 10m/s
Base rotational speed 1.2 p.u
REFERENCES
[1]. S. S. Murthy, O. P. Malik. and P. Walsh, "Capacitive VAR requirements of self-Excited
induction generators to achieve desired voltage regulation," IEEE Industrial and Commercial
Power SystemConf, Milwaukee, USA, June 1983.
[2]. M. B. Brermen and A. Abbondati, "Static exciter for induction generator," IEEE Trans, on
Ind. Appl, Vol. 13, No. 5, pp. 422-428, Sep./Oct. 1977.
[3]. Bhim Singh, Sunil kumar, “Modified power balance theory for control of DSTATCOM”
IEEE Transaction 2010.
[4]. K. R. Padiyar, “FACTS Controllers in Power Transmission and Distribution,” New Age
International (P) Limited, Publishers, New Delhi, 2007.
[5]. B.Singh, S.S.Murthy and S.Gupta, “Analysis and design of STATCOM Based Voltage
Regulator for Self-Excited Induction generators,” IEEE Transactions on Energy
Conversion, vol.19, no.4, Dec 2004, pp.783-790.
[6]. B. Singh, P. Jayaprakash, T.R. Somayajulu, D.P. Kothari, A. Chandra, and K. Al-Haddad,
“Integrated three-leg VSC with a zig-zag transformer based three-phase four-wire
DSTATCOM for power quality improvement,” in Proc. of IECON 2008, Nov. 2008, pp. 796
-80.
[7]. Haider M. Husen , Laith O. Maheemed and Prof. D.S. Chavan, “Enhancement of Power
Quality in Grid-Connected Doubly Fed Wind Turbines Induction Generator”, International
Journal of Electrical Engineering & Technology (IJEET), Volume 3, Issue 1, 2012,
pp. 182 - 196, ISSN Print : 0976-6545, ISSN Online: 0976-6553.
[8]. Youssef A. Mobarak, “Svc, Statcom, and Transmission Line Rating Enhancments on
Induction Generator Driven By Wind Turbine”, International Journal of Electrical
Engineering & Technology (IJEET), Volume 3, Issue 1, 2012, pp. 326 - 343, ISSN Print :
0976-6545, ISSN Online: 0976-6553.

More Related Content

PDF
Bh4201396402
PDF
Best Power Surge Using Fuzzy Controlled Genetic Technique
PDF
Bd32773778
PDF
20120140504018
PDF
Wind-Driven SEIG Systems: A Comparison Study
PDF
A Review on Various Topologies of Generators, Power Converters and Control Sc...
PDF
FIRING ANGLE SVC MODEL FOR ANALYZING THE PERFORMANCE OF TRANSMISSION NETWORK ...
PDF
Control of PMSG based variable speed wind energy conversion system connected ...
Bh4201396402
Best Power Surge Using Fuzzy Controlled Genetic Technique
Bd32773778
20120140504018
Wind-Driven SEIG Systems: A Comparison Study
A Review on Various Topologies of Generators, Power Converters and Control Sc...
FIRING ANGLE SVC MODEL FOR ANALYZING THE PERFORMANCE OF TRANSMISSION NETWORK ...
Control of PMSG based variable speed wind energy conversion system connected ...

What's hot (18)

PDF
Wind energy conversion systems using fuzzy controlled statcom for power qua
PPT
TRANSIENT STABILITY CONSTRAINTS FOR OPTIMAL POWER FLOW - MATHANKUMAR.S - VMKVEC
PDF
Next Generation Researchers in Power Systems_Tao Yang_UCD EI
PDF
Comparative Analysis of low area and low power D Flip-Flop for Different Logi...
PDF
SRF THEORY BASED STATCOM FOR COMPENSATION OF REACTIVE POWER AND HARMONICS
PDF
Speed Control System for BLDC Motor by using Direct Back EMF Detection Mathod
PDF
Analysis of wind turbine driven permanent magnet synchronous generator under ...
PDF
Gt3412451250
PDF
REDUCTION OF HARMONIC DISTORTION IN BLDC DRIVE USING BL-BUCK BOOST CONVERTER ...
PDF
Modeling and performance analysis of a small scale direct driven pmsg based w...
PDF
Comparison of Multi-Machine Transient Stability Limit Using UPFC
PDF
State space vector based advanced direct power control of matrix converter as...
PDF
Power flow control in parallel transmission lines based on UPFC
PDF
Analysis of Design, and Control of Sustainable Energy Based Hybrid Power System
PDF
NON-ISOLATED SOFT SWITCHING DC-DC CONVERTER AND LOAD AT FULL RANGE OF ZVS
PPTX
Power System Analysis unit - I
PDF
Emulated reactance and resistance by a SSSC incorporating energy storage device
PDF
To Study, Analysis and Implementation of Power Quality Improvement Using DSTA...
Wind energy conversion systems using fuzzy controlled statcom for power qua
TRANSIENT STABILITY CONSTRAINTS FOR OPTIMAL POWER FLOW - MATHANKUMAR.S - VMKVEC
Next Generation Researchers in Power Systems_Tao Yang_UCD EI
Comparative Analysis of low area and low power D Flip-Flop for Different Logi...
SRF THEORY BASED STATCOM FOR COMPENSATION OF REACTIVE POWER AND HARMONICS
Speed Control System for BLDC Motor by using Direct Back EMF Detection Mathod
Analysis of wind turbine driven permanent magnet synchronous generator under ...
Gt3412451250
REDUCTION OF HARMONIC DISTORTION IN BLDC DRIVE USING BL-BUCK BOOST CONVERTER ...
Modeling and performance analysis of a small scale direct driven pmsg based w...
Comparison of Multi-Machine Transient Stability Limit Using UPFC
State space vector based advanced direct power control of matrix converter as...
Power flow control in parallel transmission lines based on UPFC
Analysis of Design, and Control of Sustainable Energy Based Hybrid Power System
NON-ISOLATED SOFT SWITCHING DC-DC CONVERTER AND LOAD AT FULL RANGE OF ZVS
Power System Analysis unit - I
Emulated reactance and resistance by a SSSC incorporating energy storage device
To Study, Analysis and Implementation of Power Quality Improvement Using DSTA...
Ad

Viewers also liked (20)

PDF
Investigating the effect of machining parameters on surface roughness
PDF
Strong coupling model for high tc copper-oxide superconductors
PDF
Comparison and improvement of image compression
PDF
Water use management considering single and dual crop coefficient concept un
PDF
Optimization of wall thickness and material for minimum heat losses
PDF
A framework for efficient routing protocol metrics for wireless mesh networ
PDF
Consumer behaviour a key influencer of rural market potential
PDF
Univ. aut. sinaloa
PPTX
Mayra realidad
PPTX
Estrategias de aplicacion carmen garcia espinoza
PPTX
METACOM - Um Método para Análise de Correlação entre Métricas de Produto de S...
PPT
Copia de aparatorespiratorio
PPT
Presentación2
RTF
Manifiesto sobre la_literatura_infantil
PPTX
Normatividad gbi
PDF
Formacao pordata trabalho_final_dorespinto_fev2015
PDF
TDC2013: ExtJS 4: Dicas e Melhores Practicas
PPTX
Álbum Digital - Dara Morales Portilla
DOCX
Competencia comunicativa
Investigating the effect of machining parameters on surface roughness
Strong coupling model for high tc copper-oxide superconductors
Comparison and improvement of image compression
Water use management considering single and dual crop coefficient concept un
Optimization of wall thickness and material for minimum heat losses
A framework for efficient routing protocol metrics for wireless mesh networ
Consumer behaviour a key influencer of rural market potential
Univ. aut. sinaloa
Mayra realidad
Estrategias de aplicacion carmen garcia espinoza
METACOM - Um Método para Análise de Correlação entre Métricas de Produto de S...
Copia de aparatorespiratorio
Presentación2
Manifiesto sobre la_literatura_infantil
Normatividad gbi
Formacao pordata trabalho_final_dorespinto_fev2015
TDC2013: ExtJS 4: Dicas e Melhores Practicas
Álbum Digital - Dara Morales Portilla
Competencia comunicativa
Ad

Similar to Dstatcom based voltage regulator for wind turbine driven self excited indu (20)

PDF
Performance investigation of stand-alone induction generator based on STATCOM...
PDF
jyoti1.pdf
PDF
IRJET- Power Quality Improvement in SEIG
PDF
The Self Excited Induction Generator with Observation Magnetizing Characteris...
PPTX
induction generator final.pptx
PDF
Design Calculation of Three Phase Self Excited Induction Generator Driven by ...
PDF
Experimental dSPACE Analysis for Self-excited Induction Generator Used in Vol...
PPTX
BATCH_3_VOLTAGE_STABILITYhghgjhcvkkjmh.pptx
PDF
Design of a mode decoupling facts device for voltage control of wind driven i...
PDF
Vector control of wind driven self excited induction generator connected to g...
PDF
11.vector control of wind driven self excited induction generator connected t...
PDF
Performance Characteristics of SEIGUsed In Wind Energy Conversion System
PDF
Stator flux oriented vector control of wind driven self excited induction gen...
PDF
Voltage Compensation in Wind Power System using STATCOM Controlled by Soft Co...
PDF
Integration of a Wind Turbine Based Doubly Fed Induction Generator Using STAT...
PPTX
Introduction of Dynamic Voltage Restorer at wind Turbine farm.pptx
PDF
Bc33315326
PDF
Bc33315326
Performance investigation of stand-alone induction generator based on STATCOM...
jyoti1.pdf
IRJET- Power Quality Improvement in SEIG
The Self Excited Induction Generator with Observation Magnetizing Characteris...
induction generator final.pptx
Design Calculation of Three Phase Self Excited Induction Generator Driven by ...
Experimental dSPACE Analysis for Self-excited Induction Generator Used in Vol...
BATCH_3_VOLTAGE_STABILITYhghgjhcvkkjmh.pptx
Design of a mode decoupling facts device for voltage control of wind driven i...
Vector control of wind driven self excited induction generator connected to g...
11.vector control of wind driven self excited induction generator connected t...
Performance Characteristics of SEIGUsed In Wind Energy Conversion System
Stator flux oriented vector control of wind driven self excited induction gen...
Voltage Compensation in Wind Power System using STATCOM Controlled by Soft Co...
Integration of a Wind Turbine Based Doubly Fed Induction Generator Using STAT...
Introduction of Dynamic Voltage Restorer at wind Turbine farm.pptx
Bc33315326
Bc33315326

More from IAEME Publication (20)

PDF
IAEME_Publication_Call_for_Paper_September_2022.pdf
PDF
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
PDF
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
PDF
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
PDF
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
PDF
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
PDF
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
PDF
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
PDF
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
PDF
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
PDF
GANDHI ON NON-VIOLENT POLICE
PDF
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
PDF
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
PDF
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
PDF
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
PDF
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
PDF
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
PDF
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
PDF
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
PDF
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
IAEME_Publication_Call_for_Paper_September_2022.pdf
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
GANDHI ON NON-VIOLENT POLICE
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT

Recently uploaded (20)

PDF
pdfcoffee.com-opt-b1plus-sb-answers.pdfvi
PDF
NISM Series V-A MFD Workbook v December 2024.khhhjtgvwevoypdnew one must use ...
PDF
COST SHEET- Tender and Quotation unit 2.pdf
PPT
Chapter four Project-Preparation material
PPTX
5 Stages of group development guide.pptx
PDF
Solara Labs: Empowering Health through Innovative Nutraceutical Solutions
PPTX
job Avenue by vinith.pptxvnbvnvnvbnvbnbmnbmbh
PDF
Tata consultancy services case study shri Sharda college, basrur
PDF
Types of control:Qualitative vs Quantitative
PDF
Katrina Stoneking: Shaking Up the Alcohol Beverage Industry
PDF
Reconciliation AND MEMORANDUM RECONCILATION
PPTX
Dragon_Fruit_Cultivation_in Nepal ppt.pptx
PDF
Outsourced Audit & Assurance in USA Why Globus Finanza is Your Trusted Choice
PDF
DOC-20250806-WA0002._20250806_112011_0000.pdf
PDF
BsN 7th Sem Course GridNNNNNNNN CCN.pdf
PPTX
Probability Distribution, binomial distribution, poisson distribution
PDF
Ôn tập tiếng anh trong kinh doanh nâng cao
PDF
Elevate Cleaning Efficiency Using Tallfly Hair Remover Roller Factory Expertise
PPTX
CkgxkgxydkydyldylydlydyldlyddolydyoyyU2.pptx
PPTX
2025 Product Deck V1.0.pptxCATALOGTCLCIA
pdfcoffee.com-opt-b1plus-sb-answers.pdfvi
NISM Series V-A MFD Workbook v December 2024.khhhjtgvwevoypdnew one must use ...
COST SHEET- Tender and Quotation unit 2.pdf
Chapter four Project-Preparation material
5 Stages of group development guide.pptx
Solara Labs: Empowering Health through Innovative Nutraceutical Solutions
job Avenue by vinith.pptxvnbvnvnvbnvbnbmnbmbh
Tata consultancy services case study shri Sharda college, basrur
Types of control:Qualitative vs Quantitative
Katrina Stoneking: Shaking Up the Alcohol Beverage Industry
Reconciliation AND MEMORANDUM RECONCILATION
Dragon_Fruit_Cultivation_in Nepal ppt.pptx
Outsourced Audit & Assurance in USA Why Globus Finanza is Your Trusted Choice
DOC-20250806-WA0002._20250806_112011_0000.pdf
BsN 7th Sem Course GridNNNNNNNN CCN.pdf
Probability Distribution, binomial distribution, poisson distribution
Ôn tập tiếng anh trong kinh doanh nâng cao
Elevate Cleaning Efficiency Using Tallfly Hair Remover Roller Factory Expertise
CkgxkgxydkydyldylydlydyldlyddolydyoyyU2.pptx
2025 Product Deck V1.0.pptxCATALOGTCLCIA

Dstatcom based voltage regulator for wind turbine driven self excited indu

  • 1. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME 209 DSTATCOM BASED VOLTAGE REGULATOR FOR WIND TURBINE DRIVEN SELF-EXCITED INDUCTION GENERATOR Dr. RAJSEH KUMAR AHUJA, PRIYANKA PHAGERIA YMCA University of Science & Technology, Faridabad ABSTRACT Voltage sag is the most important powerquality problems faced by many industries and utilities.This paper presents the voltage sag mitigation usingDSTATCOM (Distribution Static Compensator).DSTATCOM is used for reactive power compensation. This paper presents an analysis of the three-phaseself-excited induction generator (SEIG) with DSTATCOM as a voltage regulator , which provides fast dynamic response tomaintain constant voltage at SEIG terminals during severeload perturbations and acts as a source and sink of reactivepower.Thispaper evaluates vector control algorithm forextracting reference source currents for voltage regulationat PCC (Point of Common Coupling) for DSTATCOM. Thevoltage source converter (VSC) is used with DC linkcapacitor as a DSTATCOM. 1. INTRODUCTION Power Quality problem such as Voltage sag is the most important power quality problems faced by many industries and utilities. It contributes more than 80% power quality (PQ) problems that exist in power systems. The majority of power consumption has been drawn in reactive loads.These excessive reactive power demandincreases feeder losses and reduces the active power flow capability of distribution system which also affects thevoltage profile. The reason for this is the majority of loads in the distribution systems are linear laggingpower factor and nonlinear, balanced and unbalanced loads. Such power quality problems can be mitigatedby the DSTATCOM (Distribution Static Synchronous Compensator) at the point of common coupling (PCC). Induction Generators used in stand- alone as well as grid connected system as recent development has done in pollution free power generation schemes.When a capacitor bank is connected across the Induction INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET) ISSN 0976 – 6545(Print) ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), pp. 209-219 © IAEME: www.iaeme.com/ijeet.asp Journal Impact Factor (2013): 5.5028 (Calculated by GISI) www.jifactor.com IJEET © I A E M E
  • 2. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME 210 Generator then it Known as a Self-Excited Induction generator. It is well known that when capacitors are connectedacross the stator terminals of an induction machine,driven by an external prime mover, voltage will beinduced at its terminals . The induced emf andcurrent in the stator windings will continue to rise untilsteady state is attained, it means reactive power supplied by capacitor bank is balanced by reactive power absorbed by load. In order for self- excitationto occur, for a particular capacitance value there is acorresponding minimum speed. The self-excited induction generator (SEIG) has some advantages over the synchronous generator, for example:brushless (squirrel-cage rotor), reduced size, rugged and low cost. However, the induction generator offers poor voltage regulation and its value depends on the prime mover speed,capacitor bank size and load characteristics. The generated voltage of the SEIG is mainly depends upon the excitation capacitance values, change in wind velocity and load conditions. The reactive power requirementby the induction generator can also be supplied by a group of capacitors. If the capacitance is insufficient,the induction generators will not build up voltage. The main drawback of the induction generator is need ofreactive to build up the terminal voltage. In the SEIG, the excitation current is supplied by the capacitors connected across its terminals. Self-excited induction generators are good candidates for wind powered electric generation application especially in remote areas, because they do not need external power supply to produce the magnetic field. By using the DSTATCOM the voltage across the SEIG remains constant at varying loads.Thesimulated results demonstrate the use of DSTATCOM as a voltage regulator across a SEIG network. 2. CONTROL SCHEME When used in low voltage distribution system, thestatic compensator (STATCOM) is identified asDistribution STATCOM (DSTATCOM). In generalDSTATCOM is used to generate or absorb reactivepower.The D-STATCOM is a three-phase and shunt connected power electronics based device. When a DSTATCOM is connected across the SEIG then the additional demand ofreactive power is fulfilled by the DSTATCOM under varyingloads. The DSTATCOM acts as a source of lagging or leadingcurrents to maintain the terminal voltage constant with variation in load.The DSTATCOM consists of a three-phaseIGBT (Insulated gate bipolar transistor) based currentcontrolled voltage source inverter, DC bus capacitor and ACinductors. The AC output of the inverter is connectedthrough the AC filtering inductor to the SEIG terminals.The DC bus capacitor is used as an energy storage deviceand provides self-supporting DC bus. The control technique to regulate the terminal voltage of theSEIG is based on the control of source currents (having twocomponents one in-phase and other quadrature). PLL is used to generate the sin(wt) and cos(wt). The two measurement systems(Vmeas and Imeas) blocks compute the d-axis and q-axis components of the voltages and currents by executing an abc-dq transformation in the synchronous reference determined by sin(wt) and cos(wt) provided by the PLL,this block calculate the mag V and IdIq current. TheAC terminal voltage (V) is compared with the reference voltage. The voltage error is processed in the PI controller. The output of the PI controller (lq ref) for AC voltage control loop decides the amplitude of reactive current required for the system.The DC bus voltage of the STATCOM is sensed and compared with DC reference voltage. The error voltage is processed in another PI controller. The output of this PI controller (Id ref) decides
  • 3. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME 211 the amplitude of active current, which is required by DSTATCOM to maintain constant DC bus voltage. The quadrature and in-phase components is thesource reference current, which is compared with the SEIG line current. The error current is processed in PID controller.The output of this PID controller maintains the primary voltage equal to the reference value. This VqVd is further used to generate reference voltage for Voltage source converter. 3. MATHEMATICAL MODELLING Modelling of SEIG The dynamic model of the three-phase SEIG is developedusing stationary d-q axes references frame is used because it provides a complete solution for dynamic analysis and control. The flux linkages per second taken into account the saturation effect are Circuit for q axis and q axis of IG Vqs=rsiqs+ωφds+d/dt(φqs) Vds=rsids-ωφqs+d/dt(φds) V’qr = r’ri’qr + (ω - ωr )φ’dr +d/dt(φ’qr) V’dr= r’ri’dr - (ω - ωr )φ’qr +d/dt(φ’dr) φqs = Llsiqs + Lm (iqs + i'qr) φds = Llsids + Lm (ids + i'dr) φ’qr = L’lriqr + Lm (iqs + i'qr) φ’dr = L’lri’dr + Lm (ids + i'dr)
  • 4. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME 212 In the above equations, all the rotor variables are referredto the stator side. The expression for the electromagnetic Torque of the SEIG is expressed as in per (unit can be written as:) Te=(3/2)(p/2)Lm(φdsiqs- φdsids) The electromagnetic torque balance equation of SEIG isdefined as Tshaft = TB + J(2/P)p(ωr) The derivative of rotor speed of the SEIG- pωr={P/(2J)}(Tshaft-Te) Modelling of wind turbine The wind turbine is characterized by no dimensional curves of the power coefficient Cp as a function of both the tip speed ratio, ë and the blade pitch angle, Â. In order to fully utilize the available wind energy, the value of ë should be maintained at its optimum value. Therefore, the power coefficient corresponding to that value will become maximum. The output power of the wind turbine, can be calculated from the following equation Pm=.5AρCp(λ,β)V3 wind where Pm=Mechanical output power of the turbine (W) Cp=Performance coefficient of the turbine Ρ=Air density (kg/m3) A=Turbine swept area (m2) Vwind=Wind speed (m/s) λ =Tip speed ratio of the rotor blade tip speed to wind speed β=Blade pitch angle (deg) Pm can be normalized. In the per unit (pu) system we have:- Pm_pu=.5AρCp_pu(λ,β)V3 wind_pu generic equation is used to model cp(λ,β). This equation, based on the modelling turbine characteristics of [1], is:-
  • 5. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME 213 The non-linear, dimensionless Cpcharacteristic is represented as .:- Cp(λ,β)=C1(C2/ λi-C3 β-C4)e-(C5/ λi)+ C6λi With (1/λi)=(1/( λ+0.08 β))-(0.035/( β3 +1)) where, C1 = 0.5176, C2 = 116, C3 = 0.4, C4 = 5, C5 = 21, C6 = 0.0068 Modelling of DSTATCOM Three-phase voltages at the SEIG terminals (va, vb and vc) are considered Convert this sinusoidal voltage into dq0. Vd = 2/3*[Va*sin(wt) + Vb*sin(wt-2pi/3) + Vc*sin(wt+2pi/3)] Vq = 2/3*[Va*cos(wt) + Vb*cos(wt-2pi/3) + Vc*cos(wt+2pi/3)] V0 = 1/3*[Va + Vb + Vc ] Amplitude is:- V=√(Vd2 +Vq2 ) Three phase current at the SEIG terminals(Ia,Ib,Ic) are considered.and convert this current into Id Iq I0. Id = 2/3*[Ia*sin(wt) + Ib*sin(wt-2pi/3) + Ic*sin(wt+2pi/3)] Iq = 2/3*[Ia*cos(wt) + Ib*cos(wt-2pi/3) + Ic*cos(wt+2pi/3)] I0 = 1/3*[Ia + Ib + Ic ] The active power component of the source current isId* which is required for the self supporting DC bus ofDSTATCOM. Moreover, the reactive component isIq* which is required for maintaining the amplitude of the PCC voltage. The active component of the load currentId* can be expressed as:- I* q = kpVdce+ki∫Vdcedt Vdce=Vdc*-Vdc
  • 6. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME 214 Vdce error in DC bus voltage.Vdc*and Vdc are the reference voltage and sensed filteredvoltage of DC bus of DSTATCOM respectively. Kp and Ki are the proportional and integral gains of the PI controller over the DC bus voltage of DSTATCOM. I*d=kpVte+ki∫Vtedt Vte=V*t-Vt Vte=error in amplitude of the PCCvoltage. Vt* and Vt are reference voltage and amplitude of PCC voltage respectively. Kpand Ki are proportional and integral gains of the PI controller over the PCCvoltage. Now this I*d I*q is compared with Id Iq and the error signal is given to the controller and the output of controller iusVdVq. Vd=KpIde+Ki∫Idedt+Kd(d/dt)Ide Where Ide=Id-I*d Vq=kpIqe+ki∫Iqedt+kd(d/dt)Iqe Where Iqe=Iq-I*q This VqVd is further used to generate reference voltage for Voltage source converter. 4. SIMULATION RESULTS AND DISCUSSION Simulations have been carried out for a 7.5kW threephase- SEIG with balanced, unbalanced resistive and reactive at 0.8 PF and nonlinear load. Disconnecting one or two phases of loads from the SEIG has created unbalanced conditions. The DC bus voltage of DSTATCOM is selected 700V for the source line voltage of 400 V. The VSC is connected to the network through the AC inductor of 800mH. For self- supporting DC bus of DSTATCOM, a capacitor of 6000µF is used. Initially considered linear reactive load is 3-single phase load.The PCC line voltage is considered 700 V,The simulation results are taken for the above mentioned load conditions. A. Performance of DSTATCOM with and Without in Balanced load condition The SEIG system under balanced load without connecting the FACT device i.e. DSTATCOM. Here asynchronous machine driven by wind turbine is connected across the various balanced loads. This asynchronous machine is converted into SEIG by connecting a capacitor bank.The balanced loads consist of two reactive loads (0.8 lagging) and one resistive load. The first reactive load is applied at the starting of the simulation, the second reactive load comes at 2 seconds after starting and the resistive load comes after 2.5 seconds. Fig. 1 (a), (b) & (c) shows the variations in load voltage, load current and stator current with respect to variations in applied load and wind speed. It is depicted that at instant 2 sec. as load increases from 7A to 9A the load voltage falls to 290V from 470V. Further at
  • 7. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME 215 instant 2.5 sec as load increases to 10A the load voltage falls to 300V from 340V. It is also clear that the voltage and currents are also changing with the variations in wind speeds. The load voltage drops marginally from 500V to 470V when wind speed changes from 12m/s to 10m/s at instant 1.95 sec. At 2.2 sec. the wind speed increases to 11m/s resulting in increase in load voltage to 340V from 290V. There are also marginal variations observed in load current and stator current. This shows that the Voltage across the SEIG not constant, so to maintain voltage constant across the SEIG DSTATCOM is connected. Fig. 1 (a) Load Voltage, (b) Load Current, (c) Stator Current and (d) Wind Speed Now, The DSTATCOM is connecting across the SEIG to improve the Voltage profile. By comparing the results of with and without DSTATCOM on SEIG system in has observed that the DSTATCOM maintains the voltage profile of load voltage as constant irrespective of changes in load and wind speed. The DSTATCOM injects sufficient reactive power into the system so as to maintain the load voltage constant. It has also observed that the profile of stator current has also got improved. When the load is increased across the generator then the reactive power is shared by IG and load so the IG needs some reactive power to maintain the voltage constant. This Reactive power demand fulfil by connecting the DSTATCOM across the generator.
  • 8. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME 216 Fig. 2 (a) load voltage, (b) load current, (c) stator current and (d) wind speed B. Performance of DSTATCOM with and without in non-linear load condition Now connect a non-linear load across the SEIG system without connecting the FACT device i.e. DSTATCOM Fig. 3 (a) load voltage, (b) load current, (c) stator current and (d) wind speed The non-linear load injects the harmonics in system and distorts the currents & voltages and also de-rates the machine.
  • 9. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME 217 In Fig. 3 when wind speed is change the voltage across the IG is changes respectively and when load is increased across the IG the voltage is decreased.to make the voltage profile constant a FACTS device is connected across the SEIG.A FACTS device DSTATCOM is connected across the SEIG to improve the voltage profile of the system and also remove the harmonics in system By comparing the results of the effect of non-linear load on SEIG system after the inclusion of DSTATCOM it has observed that it not only fulfils the reactive power demand of the system but also minimises the harmonics in the system. It is clear from Fig. 4 that the effects of non-linearity on load voltage and stator current are considerably reduced. . Fig. 4 (a) load voltage, (b) load current, (c) stator current and (d) wind speed In this way DSTATCOM also restores the rating of the machine which has reduced due to the effects of harmonics. THD of non-linear load in system without DSTATCOM THD for Stator voltage = 42.18%
  • 10. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME 218 THD for stator current = 71.34% THD of non-linear load in system with DSTATCOM THD for Stator voltage = 9.39% THD for stator current = 6.98%
  • 11. International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 – 6545(Print), ISSN 0976 – 6553(Online) Volume 4, Issue 3, May - June (2013), © IAEME 219 5. CONCLUSION A mathematical model of three-phase self-excited induction generator with DSTATCOM based voltage regulator under balanced/unbalanced/non-linear loads is studied in this project. It is concluded from the simulated results that the DSTATCOM acts as an ideal voltage regulator and load balancing device, which maintains the SEIG voltage constant and balances the SEIG system at varying balanced, unbalanced and non-linear loads APPENDIX A Parameters of machine Rated power 10 HP(7.5 KW) Voltage 400V Frequency 50HZ RPM 1440 Capacitor Bank 7.5 KVAR Parameters of wind turbine Nominal power 7650W Base power 7650(VA) Base speed 10 Max power at base wind speed 10m/s Base rotational speed 1.2 p.u REFERENCES [1]. S. S. Murthy, O. P. Malik. and P. Walsh, "Capacitive VAR requirements of self-Excited induction generators to achieve desired voltage regulation," IEEE Industrial and Commercial Power SystemConf, Milwaukee, USA, June 1983. [2]. M. B. Brermen and A. Abbondati, "Static exciter for induction generator," IEEE Trans, on Ind. Appl, Vol. 13, No. 5, pp. 422-428, Sep./Oct. 1977. [3]. Bhim Singh, Sunil kumar, “Modified power balance theory for control of DSTATCOM” IEEE Transaction 2010. [4]. K. R. Padiyar, “FACTS Controllers in Power Transmission and Distribution,” New Age International (P) Limited, Publishers, New Delhi, 2007. [5]. B.Singh, S.S.Murthy and S.Gupta, “Analysis and design of STATCOM Based Voltage Regulator for Self-Excited Induction generators,” IEEE Transactions on Energy Conversion, vol.19, no.4, Dec 2004, pp.783-790. [6]. B. Singh, P. Jayaprakash, T.R. Somayajulu, D.P. Kothari, A. Chandra, and K. Al-Haddad, “Integrated three-leg VSC with a zig-zag transformer based three-phase four-wire DSTATCOM for power quality improvement,” in Proc. of IECON 2008, Nov. 2008, pp. 796 -80. [7]. Haider M. Husen , Laith O. Maheemed and Prof. D.S. Chavan, “Enhancement of Power Quality in Grid-Connected Doubly Fed Wind Turbines Induction Generator”, International Journal of Electrical Engineering & Technology (IJEET), Volume 3, Issue 1, 2012, pp. 182 - 196, ISSN Print : 0976-6545, ISSN Online: 0976-6553. [8]. Youssef A. Mobarak, “Svc, Statcom, and Transmission Line Rating Enhancments on Induction Generator Driven By Wind Turbine”, International Journal of Electrical Engineering & Technology (IJEET), Volume 3, Issue 1, 2012, pp. 326 - 343, ISSN Print : 0976-6545, ISSN Online: 0976-6553.