SlideShare a Scribd company logo
Ec tlistener
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 1
ECTlistener v2.x.x
User Guide
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 2
About ECTlistener
ECTistener software, created and developed by EyeComTec (https://eyecomtec.com) is intended to analyze
sound signals from any microphone. Depending on the length and volume of the signal, ECTlistener emulates
key strokes and sends control codes to the receiving software.
The program was created for disabled people (paralyzed or those with extremely reduced mobility) and works
in conjunction with other programs (e.g. ECTkeyboard symbol matrix). By using a personal computer with a
microphone and both ECTlistener and ECTkeyboard, patients can type text letter-by-letter by using
individualized vocal prompts such as moans, loud breathing, sniffing and many other sounds. This allows them
to communicate with their relatives, friends, service or medical staff.
To start the program the user needs only a personal computer equipped with a microphone which are freely
available in any electronic or computer shop. ECTlistener can even work on very old personal computers with
low productivity, due to the program’s low system requirements. Furthermore, fast export or import of all
settings, the small size of the program and the ability to work without any installation, allows the user to
execute ECTlistener from any removable device, for example, flash card, external hard drive etc.
The program is really customizable and has a user-friendly interface. Initial settings take only few minutes to
operate and program is ready to work! ECTlistener is free for any private use, contains no advertising and
supports many languages.
The user can utilize the program almost immediately after set-up – all the user needs is the ability to download a
small archive with the program, and any personal computer or laptop with a microphone. All these features
make ECTlistener an extremely affordable, practical and convenient solution for people with restricted
mobility.
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 3
(Fig. 1 ECTlistener About Window)
(Fig. 1a ECTlistener Main Window)
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 4
Benefits of using ECTlistener
At the present moment, there are some similar solutions available on the market, which work with several
symbol matrix using the user’s ability to draw in the air. However, to EyeTecCom’s knowledge, all of these
programs require special devices, such as those that control air-pressure during the user inhaling and exhaling.
The main advantage of ECTlistener is that it has the same level of effectiveness without the need for having any
special (and expensive) equipment! All the user needs to operate the program is a standard microphone. This
makes our solution to text-to-speech for users so easy and affordable. Alternative solutions are not freely
available and can only be bought directly from a manufacturer, which means additional payments and delays for
delivery. Since ECTlistener is a fully-functional software solution, the user can start to operate the program
almost immediately after acquiring the software. If the user has any personal computer or laptop with a
microphone, all they need is to download a small archive with the program and spend a couple of minutes for
the initial set-up
Here are some other benefits of the ECTlistener program:
 Ease to configure. To start operating, the user just needs to change a few parameters and configure the
microphone’s location and sensitivity. After that, the user can start operating the program.
 User friendly interface. There are no excess protocols or debug modes in the program, and
simultaneously, the user can observe all necessary parameters for correct operation.
 Portability and small size of the program. ECTlistener can be executed from any portable device and
there are no installation or registry changes required.
 Low system requirements guarantee stable work of the program - even on computers with low
productivity or with older models.
 Possibility of fast export or import of settings. This feature allows “hot key” changes of configuration
files, making it possible to work with several different users (receiving applications).
 Different localizations. Independently to the user’s native language, it is possible to use any desired
language using the corresponding language file.
 Free of ads, spyware or any malicious third-party applications.
 The program is totally free for any non-commercial private use.
These benefits make EyeComTec’s ECTlistener the most affordable and comfortable solution for people with
seriously reduced mobility to communicate effectively with others with minimum expenses on equipment.
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 5
ECTlistener Quick Start
To start using ECTlistener, the user needs to operate the initial settings of the program. To do so, it is necessary
to complete following steps:
 Set receiving software window name
 Set desired volume levels (to identify low and strong signals)
 Set key codes for the receiving software
The user can also set parameters of impulses, for example, using short sound signals. There is a detailed
instruction in the "program parameters and ranges" chapter.
To change all parameters it is necessary to open the program settings window using Settings – Show Settings
Form item of the main menu, or by using the F3 hot key (see fig. 2).
(Fig. 2. Program settings window)
To allow ECTlistener to work in conjunction with ECTkeyboard symbol matrix and send key codes it is
necessary to fill parameter #1 with the corresponding value: "ECTkeyboard by www.eyecomtec.com".
Then, it is necessary to set minimum volume levels for low and strong signals. All sounds with a volume level
lower than the minimum level will be ignored by the program. Basic settings are: 25% for a low signal
(parameter #5); 70% for a strong signal (parameter #8). However, all these settings can vary from system to
system. This is due to the signal levels which depend on microphone sensitivity, distance to the sound source
and type of sound. Even though the user can change all parameters of microphone and its position, type of
sound depends only on the user's individual abilities. The user can create sounds such as moaning, inhaling or
exhaling, and by blowing into the microphone. Also, if the microphone is positioned close to the user, it is
possible to use a sniffling sound to operate the program.
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 6
After setting all volume levels it is necessary to select all key codes, which ECTlistener sends to any receiving
software. There are fields for low signal #3 (pressed key code) and #4 (released key code). For strong signals
there are fields #5 and #6 (see fig. 3).
(Fig. 3. Setting key codes and volume levels: green frame – for low noise level blue frame – for strong)
After completing all steps it is then necessary to correctly position the microphone so that when the user makes
a low level signal the volume level in the program window will show (for our real example) from 25% to 70%
of the program scale, and when the user makes a loud signal, more than 70%. All sounds lower than 25% will
be ignored by the program. This feature was implemented so that background noises and regular breathing from
the user is ignored and is therefore not picked up by the software.
Now ECTlistener software is ready to work in conjunction with the ECTkeyboard program. By selecting any
desired mode of ECTkeyboard, the user can start typing text letter by letter. (see fig. 4).
(Fig. 4. ECTlistener and ECTkeyboard simultaneous work)
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 7
Interface and menu
ECTlistener is based on the analysis of signals captured from any microphone. The user can set different
buttons of the keyboard and associate them with sounds using different volumes and length. ECTlistener sends
key codes to any receiving software, for example, ECTkeyboard symbol matrix.
The program’s use is mainly intended for severely paralyzed people, who find mobility and speech difficult or
restricted. To control the program the user needs to perform any sound: moans and inhalation or exhalation, as
well as many other sounds.
Interface of ECTlistener is relatively simple (see fig. 5).
(Fig. 5. Program main window interface)
There is a volume indicator in the left part of the main window of the program and current session statistics are
shown in the right side (information field). All main operations and settings are reachable through the main
menu items or corresponding "hot keys."
The information field contains some statistical data and creates a log of all actions in ECTlistener. It allows the
user to see in real time if the program works correctly. Each row contains information about a new action
performed by the user and can be decoded in the following way:
 ta - nominal time units to mark all the events. For example, “5 ta” is equal to one second.
 F - type of recognized signal:
o 0 – strong or low level signal is over
o 1 – short impulse
o 2 – long impulse
o 3 – reserved
o 4 – low level of the signal
o 5 – strong level of the signal
 key – key code sent to the receiving software. For example, the letter ‘d’ after any code means that key
has been pressed, letter ‘u’ means that key has been released.
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 8
After all the information about nominal time, signal type and key code has been logged, a timestamp displays
for each event.
To control the ECTlistener program, the user can utilize the main menu and hot keys. Let’s have a look at menu
items (see fig. 6).
(Fig. 6. Main menu of the program)
About; hot key F1. This item opens the information window that shows data about the current version of the
software and release date. It also contains a short description about the developers (see fig. 7).
(Fig. 7. 'About' window)
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 9
Start, Stop; hot key F2. Allows the user to start or stop the analysis of the sound and key codes sending to the
receiving software. If there is no active microphone in your computer, the system will not allow analysis to
begin. This item will stay in the ‘Start’ state until a microphone becomes active.
Settings submenu (see fig. 8).
(Fig. 8. 'Settings' submenu)
Show Settings Form; hot key F3. This item of the main menu allows the user to open the settings panel of the
program. Here, the user can change the receiving software name, change key codes and signal levels, change
the length of short and long impulses, and change the appearance of program log.
Set Current. Applies all settings that were made by the user in the settings panel of the program.
Reset to default. If it i’s necessary to return ECTlistener to its default settings the user can choose this option
from the main menu.
Load Profile; Ctrl+1 key combination. This item allows the user to load a previously created settings file for
the program. The user can load a previously made file within these settings.
Save Profile; Ctrl+2 key combination. Allows the user to save all program settings into the file. This option
can be useful when the user needs to move ECTlistener to another computer or portable device. This feature is
also necessary when several different people are using the program and they use different volume levels (or
receiving applications).
Localization submenu (see fig. 9).
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 10
(Fig. 9. 'Localization' submenu)
Set Language File; Ctrl+F2 key combination. This item of the main menu allows the user to translate the
program’s interface to another language (apart from English). The user will see a standard file explorer window,
where they may select any desired file with .lng extension.
Set English; Ctrl+3 key combination. Allows translating programs interface to English.
Exit; Ctrl+Alt+X key combination. Stops the analysis and closes the program.
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 11
Program Settings
Using the settings panel of the program, the user can change up to 17 different parameters, which makes it
possible to adjust the program for personal needs.
Let’s take a closer look at the parameters:
1. Name of the receiving-application's window title that will receive key codes from ECTlistener. To
operate properly with ECTkeyboard, this field must contain "ECTkeyboard by www.eyecomtec.com"
2. Program interface language. This field contains a full path to the localization file that is used at this
moment
3. "Press key" code for low signal. To work with ECTkeyboard, the user can set "32" value, which
corresponds to the space button
4. "Release key" code for low signal. Press and release codes are usually the same
5. Minimum level to recognize low signal. It’s recommended to use values from 20 to 25%
6. "Press key" code for strong signal
7. "Release key" code for strong signal
8. Minimum level to recognize strong signal. It's recommended to use values from 60 to 70%
9. "Press key" code for short impulse
10. “Release key” code for short impulse
11. Minimum length of short impulse
12. Maximum length of short impulse
13. "Press key" code for long impulse
14. "Release key" code for long impulse
15. Minimum length of long impulse
16. Maximum length of long impulse
17. Number of rows in the information field. By default, this is equal to 50, but the user can set any desired
amount of rows for comfortable work with the program
18. Name of the log file, which contains all statistical data from the information field
(Fig. 10. ECTlistener Settings Window)
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 12
Updates
The latest version of ECTlistener can be downloaded directly from our site:
https://eyecomtec.com/ECTlistener.zip
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 13
Licensing agreement
General Terms
This license agreement establishes substantive provisions, as well as describes the permitted and prohibited
ways of use of the software developed by EyeComTec. The licensee has the right to use software products of
EyeComTec only under the conditions described in this License Agreement.
All software and all related intellectual assets (copyrights, algorithms, source code and technical
documentation) are fully owned by the EyeComTec (LAZgroup SA) company. EyeComTec can provide free
exclusive and non-transferable license to any entities which are involved into charity or non-profit activities. In
order to use the software for commercial purposes, such companies have to contact us directly and purchase a
license. Any commercial use (with pecuniary interest) of the software developed by EyeComTec without
license is strictly prohibited.
During the determination of the conditions and restrictions of use, the copyright holder provided all the
information on a limited warranty basis as well as the rejection of any liability. This project is voluntary, and
the parent company is not liable for any issued support packs or updates in front of those users who use
software products of EyeComTec free of charge.
All the users are obligated to observe and follow the requirements of this License Agreement.
Restrictions on use
The end user is not allowed to use or permit the use of EyeComTec software products in any manner that may
affect their functionality, including modification of the program binary source code and participation in any
operation that is aimed at reverse engineering (decompilation) of software for personal or professional gain.
Additionally, the end user of the software under no circumstances has the right to change copyright information
or use the names of software products in an inappropriate manner in order to obtain financial or material
benefits. The user has no right to change, make copies, sell, sublicense, advertise or distribute EyeComTec
software products in any manner, which is not allowed by this license agreement. As a charitable gesture from
the company, all users are allowed to share EyeComTec software products installation packages among
themselves and with other people.
Upon receipt of the license the user does not receive any right to own copies of the software, and the copyright
holder may prohibit subsequent sales.
All licensees have no right to re-pack the software and distribute it by including the software in various
installation packages that contain malicious programs or advertisement of any form.
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 14
Registration of users
User registration is the easiest and safest way to provide feedback between the development company and its
consumers: patients and medical centers. During startup of the non-registered program, the user will see a web-
browser window with the present registration page.
 Registration Form for Private non-commercial client (people with physical needs to use our products)*
 Registration Form for Medical organizations (commercial and charitable non-profit: hospitals,
rehabilitation centers, doctors)**
 Registration Form for Commercial non-medical clients (involved in manufacturing, assembly, control,
production lines)**
* Registration is voluntary for private non-commercial customers, but nevertheless desirable.
** Registration is mandatory for legal entities and commercial clients.
Collection of such statistical data is extremely important for EyeComTec because it allows detailed information
about the needs of specific users to be obtained, and it also improves the software in accordance with user
needs. Program complex is developed continuously and many features of the current version were created due
to feedback from users.
Registration opens the opportunity to participate in a loyalty program for commercial entities. The loyalty
program starts immediately after registration is complete. Participation in the loyalty program gives users access
to current and extended versions of the software on more favorable terms, as well as providing significant
discounts.
Additionally the database of contacts allows EyeComTec to inform patients promptly about new and
unpublished software products and updates of the EyeComTec program complex. Furthermore, users are able to
receive information on the functionality of basic and advanced versions in a timely manner.
Differentiation of commercial and noncommercial license
1. Noncommercial License
1.A. Noncommercial license for clients with physical needs.
(this type of license does not apply to customers who are undergoing paid rehabilitation courses)
EyeComTec software products are provided free of charge to all users who are experiencing physical need and
are in use of such category of programs. This group of people includes all those who suffer from various forms
of paralysis or other muscular activity restrictions. All software products are free for non-commercial use, for
example when the patient uses our software for text typing, they are not obligated to purchase a commercial
license.
1.B. Noncommercial license for charitable organizations.
Charity companies and rehabilitation centers can use all EyeComTec software products free of charge if they
provide their services to patients on a free basis.
Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 15
2. Paid commercial License
2.A. Commercial license for paid clinics and rehabilitation centers.
Commercial licenses for program products of EyeComTec is necessary in any case of paid services provision by
medical companies or rehabilitation centers. Such a commercial license is required for each separate copy of the
program in use. Only one copy of each licensed program may run at the same period of time.
All assistants and third-party specialists who provide paid services to their patients and involve EyeComTec
software products in their work are also obligated to purchase a commercial license.
In any case when the user is on paid treatment, involved in rehabilitation program in commercial institution, or
uses paid services of any third-party medical specialist, they are prohibited to use personal non-commercial
license ECT software. The user is strictly prohibited to use any EyeComTec software products to communicate
directly with any paid healthcare specialist or representative of a commercial establishment. In such cases, the
rehabilitation facility or attending specialist are obligated to use and provide to the patient their own
commercially licensed copy of the software.
This restriction extends over the entire period of treatment or rehabilitation of the patient.
2.B. Commercial license for software integrators and resellers.
All companies and experienced specialists who provide paid services for the installation and integration of
EyeComTec software products to third parties, as well as maintenance and technical support for such programs,
are obligated to purchase a commercial license. Selling of software products to customers with physical needs is
strictly prohibited (see section 2.1, paragraph A).
2.C. Commercial license for extended program versions, which are intended to use in non-medical
environments.
The EyeComTec Company develops extended versions of their programs (in particular, ECTtracker) which are
successfully used in factories, shops, automated assembly lines and quality control systems. Such program
versions are distributed on individual licenses and are not intended for public distribution. In order to get full
information about features of programs, full quotation including price of purchase and support, as well as cost
of specialists training, please contact the EyeComTec Company.
Furthermore, our company develops various additional applications which can significantly enhance the
functionality of our programs. When such applications are in use with extended versions of our programs they
can be used for additional automation of analyzing and controlling manufacturing processes.
Specialists from the EyeComTec Company are ready to create individual systems which are most suitable to
your needs. The system will be created on software modules which were created, taking into account all the
distinctive features of the processes.

More Related Content

PPTX
Electronic Voting Machine
DOC
Smart Door Lock System Using DTMF
PDF
Bluetooth remote control... from your mobile phone
PPT
PPTX
Arc application remote control using bluetooth
PPT
Evm
PPTX
Evm electronic voting machine
DOCX
Electronic voting machine using mcu 89s52
Electronic Voting Machine
Smart Door Lock System Using DTMF
Bluetooth remote control... from your mobile phone
Arc application remote control using bluetooth
Evm
Evm electronic voting machine
Electronic voting machine using mcu 89s52

What's hot (19)

DOCX
finger print sensor
PPTX
LCD based voting machine using 8051 microcontroller (
PDF
fingerprint based electronic voting machine
PPTX
Mobile controlled robotic car
PPTX
Electronic voting machine
PPTX
Electronic voting machine using RFID
PDF
Ijarcet vol-2-issue-7-2389-2397
PPT
ELECTRONIC VOTING MACHINE
PPT
Electronic voting machine
PPTX
Electronic voting machine
PDF
Credibility of Electronic Voting Machines (EVMs) in India
PPTX
FINGER-PRINT BASED ELECTRONIC VOTING MACHINE
DOC
Fingerprint based electronic voting system
DOC
Final Report
PPTX
Fingerprint based voting machine ppt
PPTX
Fingerprint EVM
PDF
Android based security and home
PDF
Final Report11
finger print sensor
LCD based voting machine using 8051 microcontroller (
fingerprint based electronic voting machine
Mobile controlled robotic car
Electronic voting machine
Electronic voting machine using RFID
Ijarcet vol-2-issue-7-2389-2397
ELECTRONIC VOTING MACHINE
Electronic voting machine
Electronic voting machine
Credibility of Electronic Voting Machines (EVMs) in India
FINGER-PRINT BASED ELECTRONIC VOTING MACHINE
Fingerprint based electronic voting system
Final Report
Fingerprint based voting machine ppt
Fingerprint EVM
Android based security and home
Final Report11
Ad

More from ferelrew (20)

PDF
What is a CNC Router Machine
PDF
What is the Best Month to Get Married?
PDF
The benefits of team building
PDF
Aero Auto Glass
PDF
Résidence Koningshof
PPT
Looking for humboldt
PDF
Stephen pierce on how to never give up
PDF
What is saas
PPT
Cannabis marketing ideas
PPT
America's drug card
PPT
Fiverr gigs by thatone71
PPT
Lowermyrx
PDF
Best football tipsters
PDF
Venus worldwide skin care tools
PDF
Best fishing rods for the money
PDF
Seo company camarillo
PDF
Seo company
PDF
Erfan Taghavi
PDF
Which US Presidents are lawyers
PDF
iCarpentry
What is a CNC Router Machine
What is the Best Month to Get Married?
The benefits of team building
Aero Auto Glass
Résidence Koningshof
Looking for humboldt
Stephen pierce on how to never give up
What is saas
Cannabis marketing ideas
America's drug card
Fiverr gigs by thatone71
Lowermyrx
Best football tipsters
Venus worldwide skin care tools
Best fishing rods for the money
Seo company camarillo
Seo company
Erfan Taghavi
Which US Presidents are lawyers
iCarpentry
Ad

Recently uploaded (20)

PDF
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
PPTX
VMware vSphere Foundation How to Sell Presentation-Ver1.4-2-14-2024.pptx
PDF
Network Security Unit 5.pdf for BCA BBA.
PDF
gpt5_lecture_notes_comprehensive_20250812015547.pdf
PDF
A comparative analysis of optical character recognition models for extracting...
PDF
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
PDF
Encapsulation_ Review paper, used for researhc scholars
DOCX
The AUB Centre for AI in Media Proposal.docx
PDF
Chapter 3 Spatial Domain Image Processing.pdf
PPT
Teaching material agriculture food technology
PPTX
Spectroscopy.pptx food analysis technology
PDF
Building Integrated photovoltaic BIPV_UPV.pdf
PDF
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
PPTX
Big Data Technologies - Introduction.pptx
PDF
NewMind AI Weekly Chronicles - August'25-Week II
PDF
Electronic commerce courselecture one. Pdf
PPTX
Digital-Transformation-Roadmap-for-Companies.pptx
PDF
Spectral efficient network and resource selection model in 5G networks
PDF
Reach Out and Touch Someone: Haptics and Empathic Computing
PPTX
Machine Learning_overview_presentation.pptx
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
VMware vSphere Foundation How to Sell Presentation-Ver1.4-2-14-2024.pptx
Network Security Unit 5.pdf for BCA BBA.
gpt5_lecture_notes_comprehensive_20250812015547.pdf
A comparative analysis of optical character recognition models for extracting...
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
Encapsulation_ Review paper, used for researhc scholars
The AUB Centre for AI in Media Proposal.docx
Chapter 3 Spatial Domain Image Processing.pdf
Teaching material agriculture food technology
Spectroscopy.pptx food analysis technology
Building Integrated photovoltaic BIPV_UPV.pdf
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
Big Data Technologies - Introduction.pptx
NewMind AI Weekly Chronicles - August'25-Week II
Electronic commerce courselecture one. Pdf
Digital-Transformation-Roadmap-for-Companies.pptx
Spectral efficient network and resource selection model in 5G networks
Reach Out and Touch Someone: Haptics and Empathic Computing
Machine Learning_overview_presentation.pptx

Ec tlistener

  • 2. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 1 ECTlistener v2.x.x User Guide
  • 3. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 2 About ECTlistener ECTistener software, created and developed by EyeComTec (https://eyecomtec.com) is intended to analyze sound signals from any microphone. Depending on the length and volume of the signal, ECTlistener emulates key strokes and sends control codes to the receiving software. The program was created for disabled people (paralyzed or those with extremely reduced mobility) and works in conjunction with other programs (e.g. ECTkeyboard symbol matrix). By using a personal computer with a microphone and both ECTlistener and ECTkeyboard, patients can type text letter-by-letter by using individualized vocal prompts such as moans, loud breathing, sniffing and many other sounds. This allows them to communicate with their relatives, friends, service or medical staff. To start the program the user needs only a personal computer equipped with a microphone which are freely available in any electronic or computer shop. ECTlistener can even work on very old personal computers with low productivity, due to the program’s low system requirements. Furthermore, fast export or import of all settings, the small size of the program and the ability to work without any installation, allows the user to execute ECTlistener from any removable device, for example, flash card, external hard drive etc. The program is really customizable and has a user-friendly interface. Initial settings take only few minutes to operate and program is ready to work! ECTlistener is free for any private use, contains no advertising and supports many languages. The user can utilize the program almost immediately after set-up – all the user needs is the ability to download a small archive with the program, and any personal computer or laptop with a microphone. All these features make ECTlistener an extremely affordable, practical and convenient solution for people with restricted mobility.
  • 4. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 3 (Fig. 1 ECTlistener About Window) (Fig. 1a ECTlistener Main Window)
  • 5. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 4 Benefits of using ECTlistener At the present moment, there are some similar solutions available on the market, which work with several symbol matrix using the user’s ability to draw in the air. However, to EyeTecCom’s knowledge, all of these programs require special devices, such as those that control air-pressure during the user inhaling and exhaling. The main advantage of ECTlistener is that it has the same level of effectiveness without the need for having any special (and expensive) equipment! All the user needs to operate the program is a standard microphone. This makes our solution to text-to-speech for users so easy and affordable. Alternative solutions are not freely available and can only be bought directly from a manufacturer, which means additional payments and delays for delivery. Since ECTlistener is a fully-functional software solution, the user can start to operate the program almost immediately after acquiring the software. If the user has any personal computer or laptop with a microphone, all they need is to download a small archive with the program and spend a couple of minutes for the initial set-up Here are some other benefits of the ECTlistener program:  Ease to configure. To start operating, the user just needs to change a few parameters and configure the microphone’s location and sensitivity. After that, the user can start operating the program.  User friendly interface. There are no excess protocols or debug modes in the program, and simultaneously, the user can observe all necessary parameters for correct operation.  Portability and small size of the program. ECTlistener can be executed from any portable device and there are no installation or registry changes required.  Low system requirements guarantee stable work of the program - even on computers with low productivity or with older models.  Possibility of fast export or import of settings. This feature allows “hot key” changes of configuration files, making it possible to work with several different users (receiving applications).  Different localizations. Independently to the user’s native language, it is possible to use any desired language using the corresponding language file.  Free of ads, spyware or any malicious third-party applications.  The program is totally free for any non-commercial private use. These benefits make EyeComTec’s ECTlistener the most affordable and comfortable solution for people with seriously reduced mobility to communicate effectively with others with minimum expenses on equipment.
  • 6. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 5 ECTlistener Quick Start To start using ECTlistener, the user needs to operate the initial settings of the program. To do so, it is necessary to complete following steps:  Set receiving software window name  Set desired volume levels (to identify low and strong signals)  Set key codes for the receiving software The user can also set parameters of impulses, for example, using short sound signals. There is a detailed instruction in the "program parameters and ranges" chapter. To change all parameters it is necessary to open the program settings window using Settings – Show Settings Form item of the main menu, or by using the F3 hot key (see fig. 2). (Fig. 2. Program settings window) To allow ECTlistener to work in conjunction with ECTkeyboard symbol matrix and send key codes it is necessary to fill parameter #1 with the corresponding value: "ECTkeyboard by www.eyecomtec.com". Then, it is necessary to set minimum volume levels for low and strong signals. All sounds with a volume level lower than the minimum level will be ignored by the program. Basic settings are: 25% for a low signal (parameter #5); 70% for a strong signal (parameter #8). However, all these settings can vary from system to system. This is due to the signal levels which depend on microphone sensitivity, distance to the sound source and type of sound. Even though the user can change all parameters of microphone and its position, type of sound depends only on the user's individual abilities. The user can create sounds such as moaning, inhaling or exhaling, and by blowing into the microphone. Also, if the microphone is positioned close to the user, it is possible to use a sniffling sound to operate the program.
  • 7. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 6 After setting all volume levels it is necessary to select all key codes, which ECTlistener sends to any receiving software. There are fields for low signal #3 (pressed key code) and #4 (released key code). For strong signals there are fields #5 and #6 (see fig. 3). (Fig. 3. Setting key codes and volume levels: green frame – for low noise level blue frame – for strong) After completing all steps it is then necessary to correctly position the microphone so that when the user makes a low level signal the volume level in the program window will show (for our real example) from 25% to 70% of the program scale, and when the user makes a loud signal, more than 70%. All sounds lower than 25% will be ignored by the program. This feature was implemented so that background noises and regular breathing from the user is ignored and is therefore not picked up by the software. Now ECTlistener software is ready to work in conjunction with the ECTkeyboard program. By selecting any desired mode of ECTkeyboard, the user can start typing text letter by letter. (see fig. 4). (Fig. 4. ECTlistener and ECTkeyboard simultaneous work)
  • 8. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 7 Interface and menu ECTlistener is based on the analysis of signals captured from any microphone. The user can set different buttons of the keyboard and associate them with sounds using different volumes and length. ECTlistener sends key codes to any receiving software, for example, ECTkeyboard symbol matrix. The program’s use is mainly intended for severely paralyzed people, who find mobility and speech difficult or restricted. To control the program the user needs to perform any sound: moans and inhalation or exhalation, as well as many other sounds. Interface of ECTlistener is relatively simple (see fig. 5). (Fig. 5. Program main window interface) There is a volume indicator in the left part of the main window of the program and current session statistics are shown in the right side (information field). All main operations and settings are reachable through the main menu items or corresponding "hot keys." The information field contains some statistical data and creates a log of all actions in ECTlistener. It allows the user to see in real time if the program works correctly. Each row contains information about a new action performed by the user and can be decoded in the following way:  ta - nominal time units to mark all the events. For example, “5 ta” is equal to one second.  F - type of recognized signal: o 0 – strong or low level signal is over o 1 – short impulse o 2 – long impulse o 3 – reserved o 4 – low level of the signal o 5 – strong level of the signal  key – key code sent to the receiving software. For example, the letter ‘d’ after any code means that key has been pressed, letter ‘u’ means that key has been released.
  • 9. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 8 After all the information about nominal time, signal type and key code has been logged, a timestamp displays for each event. To control the ECTlistener program, the user can utilize the main menu and hot keys. Let’s have a look at menu items (see fig. 6). (Fig. 6. Main menu of the program) About; hot key F1. This item opens the information window that shows data about the current version of the software and release date. It also contains a short description about the developers (see fig. 7). (Fig. 7. 'About' window)
  • 10. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 9 Start, Stop; hot key F2. Allows the user to start or stop the analysis of the sound and key codes sending to the receiving software. If there is no active microphone in your computer, the system will not allow analysis to begin. This item will stay in the ‘Start’ state until a microphone becomes active. Settings submenu (see fig. 8). (Fig. 8. 'Settings' submenu) Show Settings Form; hot key F3. This item of the main menu allows the user to open the settings panel of the program. Here, the user can change the receiving software name, change key codes and signal levels, change the length of short and long impulses, and change the appearance of program log. Set Current. Applies all settings that were made by the user in the settings panel of the program. Reset to default. If it i’s necessary to return ECTlistener to its default settings the user can choose this option from the main menu. Load Profile; Ctrl+1 key combination. This item allows the user to load a previously created settings file for the program. The user can load a previously made file within these settings. Save Profile; Ctrl+2 key combination. Allows the user to save all program settings into the file. This option can be useful when the user needs to move ECTlistener to another computer or portable device. This feature is also necessary when several different people are using the program and they use different volume levels (or receiving applications). Localization submenu (see fig. 9).
  • 11. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 10 (Fig. 9. 'Localization' submenu) Set Language File; Ctrl+F2 key combination. This item of the main menu allows the user to translate the program’s interface to another language (apart from English). The user will see a standard file explorer window, where they may select any desired file with .lng extension. Set English; Ctrl+3 key combination. Allows translating programs interface to English. Exit; Ctrl+Alt+X key combination. Stops the analysis and closes the program.
  • 12. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 11 Program Settings Using the settings panel of the program, the user can change up to 17 different parameters, which makes it possible to adjust the program for personal needs. Let’s take a closer look at the parameters: 1. Name of the receiving-application's window title that will receive key codes from ECTlistener. To operate properly with ECTkeyboard, this field must contain "ECTkeyboard by www.eyecomtec.com" 2. Program interface language. This field contains a full path to the localization file that is used at this moment 3. "Press key" code for low signal. To work with ECTkeyboard, the user can set "32" value, which corresponds to the space button 4. "Release key" code for low signal. Press and release codes are usually the same 5. Minimum level to recognize low signal. It’s recommended to use values from 20 to 25% 6. "Press key" code for strong signal 7. "Release key" code for strong signal 8. Minimum level to recognize strong signal. It's recommended to use values from 60 to 70% 9. "Press key" code for short impulse 10. “Release key” code for short impulse 11. Minimum length of short impulse 12. Maximum length of short impulse 13. "Press key" code for long impulse 14. "Release key" code for long impulse 15. Minimum length of long impulse 16. Maximum length of long impulse 17. Number of rows in the information field. By default, this is equal to 50, but the user can set any desired amount of rows for comfortable work with the program 18. Name of the log file, which contains all statistical data from the information field (Fig. 10. ECTlistener Settings Window)
  • 13. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 12 Updates The latest version of ECTlistener can be downloaded directly from our site: https://eyecomtec.com/ECTlistener.zip
  • 14. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 13 Licensing agreement General Terms This license agreement establishes substantive provisions, as well as describes the permitted and prohibited ways of use of the software developed by EyeComTec. The licensee has the right to use software products of EyeComTec only under the conditions described in this License Agreement. All software and all related intellectual assets (copyrights, algorithms, source code and technical documentation) are fully owned by the EyeComTec (LAZgroup SA) company. EyeComTec can provide free exclusive and non-transferable license to any entities which are involved into charity or non-profit activities. In order to use the software for commercial purposes, such companies have to contact us directly and purchase a license. Any commercial use (with pecuniary interest) of the software developed by EyeComTec without license is strictly prohibited. During the determination of the conditions and restrictions of use, the copyright holder provided all the information on a limited warranty basis as well as the rejection of any liability. This project is voluntary, and the parent company is not liable for any issued support packs or updates in front of those users who use software products of EyeComTec free of charge. All the users are obligated to observe and follow the requirements of this License Agreement. Restrictions on use The end user is not allowed to use or permit the use of EyeComTec software products in any manner that may affect their functionality, including modification of the program binary source code and participation in any operation that is aimed at reverse engineering (decompilation) of software for personal or professional gain. Additionally, the end user of the software under no circumstances has the right to change copyright information or use the names of software products in an inappropriate manner in order to obtain financial or material benefits. The user has no right to change, make copies, sell, sublicense, advertise or distribute EyeComTec software products in any manner, which is not allowed by this license agreement. As a charitable gesture from the company, all users are allowed to share EyeComTec software products installation packages among themselves and with other people. Upon receipt of the license the user does not receive any right to own copies of the software, and the copyright holder may prohibit subsequent sales. All licensees have no right to re-pack the software and distribute it by including the software in various installation packages that contain malicious programs or advertisement of any form.
  • 15. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 14 Registration of users User registration is the easiest and safest way to provide feedback between the development company and its consumers: patients and medical centers. During startup of the non-registered program, the user will see a web- browser window with the present registration page.  Registration Form for Private non-commercial client (people with physical needs to use our products)*  Registration Form for Medical organizations (commercial and charitable non-profit: hospitals, rehabilitation centers, doctors)**  Registration Form for Commercial non-medical clients (involved in manufacturing, assembly, control, production lines)** * Registration is voluntary for private non-commercial customers, but nevertheless desirable. ** Registration is mandatory for legal entities and commercial clients. Collection of such statistical data is extremely important for EyeComTec because it allows detailed information about the needs of specific users to be obtained, and it also improves the software in accordance with user needs. Program complex is developed continuously and many features of the current version were created due to feedback from users. Registration opens the opportunity to participate in a loyalty program for commercial entities. The loyalty program starts immediately after registration is complete. Participation in the loyalty program gives users access to current and extended versions of the software on more favorable terms, as well as providing significant discounts. Additionally the database of contacts allows EyeComTec to inform patients promptly about new and unpublished software products and updates of the EyeComTec program complex. Furthermore, users are able to receive information on the functionality of basic and advanced versions in a timely manner. Differentiation of commercial and noncommercial license 1. Noncommercial License 1.A. Noncommercial license for clients with physical needs. (this type of license does not apply to customers who are undergoing paid rehabilitation courses) EyeComTec software products are provided free of charge to all users who are experiencing physical need and are in use of such category of programs. This group of people includes all those who suffer from various forms of paralysis or other muscular activity restrictions. All software products are free for non-commercial use, for example when the patient uses our software for text typing, they are not obligated to purchase a commercial license. 1.B. Noncommercial license for charitable organizations. Charity companies and rehabilitation centers can use all EyeComTec software products free of charge if they provide their services to patients on a free basis.
  • 16. Copyright © 2000 - 2015 EyeComTec.Com “LAZgroup SA” All rights reserved. Page 15 2. Paid commercial License 2.A. Commercial license for paid clinics and rehabilitation centers. Commercial licenses for program products of EyeComTec is necessary in any case of paid services provision by medical companies or rehabilitation centers. Such a commercial license is required for each separate copy of the program in use. Only one copy of each licensed program may run at the same period of time. All assistants and third-party specialists who provide paid services to their patients and involve EyeComTec software products in their work are also obligated to purchase a commercial license. In any case when the user is on paid treatment, involved in rehabilitation program in commercial institution, or uses paid services of any third-party medical specialist, they are prohibited to use personal non-commercial license ECT software. The user is strictly prohibited to use any EyeComTec software products to communicate directly with any paid healthcare specialist or representative of a commercial establishment. In such cases, the rehabilitation facility or attending specialist are obligated to use and provide to the patient their own commercially licensed copy of the software. This restriction extends over the entire period of treatment or rehabilitation of the patient. 2.B. Commercial license for software integrators and resellers. All companies and experienced specialists who provide paid services for the installation and integration of EyeComTec software products to third parties, as well as maintenance and technical support for such programs, are obligated to purchase a commercial license. Selling of software products to customers with physical needs is strictly prohibited (see section 2.1, paragraph A). 2.C. Commercial license for extended program versions, which are intended to use in non-medical environments. The EyeComTec Company develops extended versions of their programs (in particular, ECTtracker) which are successfully used in factories, shops, automated assembly lines and quality control systems. Such program versions are distributed on individual licenses and are not intended for public distribution. In order to get full information about features of programs, full quotation including price of purchase and support, as well as cost of specialists training, please contact the EyeComTec Company. Furthermore, our company develops various additional applications which can significantly enhance the functionality of our programs. When such applications are in use with extended versions of our programs they can be used for additional automation of analyzing and controlling manufacturing processes. Specialists from the EyeComTec Company are ready to create individual systems which are most suitable to your needs. The system will be created on software modules which were created, taking into account all the distinctive features of the processes.