SlideShare a Scribd company logo
Pacific Gas and
       Electric Company


Solution of EMI Problems from Operation of Variable-Frequency Drives
Background
Abrupt voltage transitions on the output terminals of a variable-frequency drive
(VFD) are an inherent source of radiated and conducted Electromagnetic
Interference (EMI). These voltage transition times are essentially determined by
the rise and fall time of the semiconductor devices used in the inverter section of
VFDs. The present tendency among drive manufacturers is to use Insulated-
Gate-Bipolar-Transistor (IGBTs) devices which have a much lower power loss
and higher switching speed than their predecessors Bipolar Junction Transistors
(BJTs).

However, these improvements result in voltage transition times that can now be
as fast as 100 ns and this high dv/dt produces higher magnitude of common-
mode (CM) noise currents in the stray line-to-ground capacitance of motor and
cables. These CM noise currents can cause electromagnetic interference and
affect control signals, encoder feedback, communication links for programmable
logic controllers, including RS-232, RS 485, Remote I/O, and different types of
sensors including, ultrasonic sensors, bar code/vision systems, weight and
temperature sensors. Conducted ground current also leads to radiated
emissions, with the drive cables acting as antennas. AM radio reception, radio-
controlled operator devices, and television are the most susceptible equipment to
this radiated interference from VFDs. The purpose of this Tech Note is to explain
the issues related to EMI problems associated with VFD operation, and to
provide recommended guidelines for end-users toward mitigating EMI problems
related to VFD operation.

Problem Description
EMI-related problems involve a source of noise, coupling of this noise by
conduction or radiation, and circuits/equipment that are susceptible to this noise.
The source of noise from VFD operation is the high dv/dt of pulse-width
modulated (PWM) output voltage waveforms. As can be seen from Figure 1,
the stray capacitance to ground of cables and motors results in high
frequency ground currents, the magnitude of which is determined by the equation
I = C dv/dt.

The high ground impedance at high frequency results in instantaneous voltage
differences between two points reputed to be “ground potential.” This voltage
appears as a common-mode noise voltage that can interfere with control signals
and other communication devices. CM noise may also be capacitively coupled
onto control signal cables that are in close proximity of unshielded VFD power
leads. Conducted ground currents also lead to radiated interference, with the
unshielded phase conductor, the stray capacitance, and the ground return path
acting as a loop antenna. With the increasing use of VFDs in commercial and
residential applications, the possibility of radio interference from VFDs is an issue

                                          1
of concern for end-users. Sometimes this radio interference can affect other
customers in the neighborhood of the VFD application.

The rise time of the VFD output waveform and the switching frequency of the inverter
determine the frequency of the radiated and conducted noise. The switching
frequency, which is typically in the range of 1 kHz to 16 kHz, determines the low-
frequency conducted noise spectrum. The rise time of modern IGBT inverters can be
in the range of 50 ns to 500 ns. This results in a noise frequency
fn= 0.318/Trise, respectively 6 MHz to 600 kHz.

Preventive Measures to Minimize EMI Problems
EMI problems can be minimized to a great degree by adopting preventive
measures during the installation phase of VFDs. The most successful preventive
measure is to use a shielded power cable to connect the VFD to the motor. This
forces the noise current to flow through the shield back to the inverter, before it
gets out into the system grid and takes multiple high frequency paths which are
difficult to track down in an installation.

The use of shielded power cables also reduces the area of the loop antenna that
is responsible for radiated interference. The shield should be connected to
ground at both ends. It is important to ensure good electrical contact from the
installation plate through the installation screws to the metal cabinet of the VFD.
Cable clamps should be used instead of twisted shield ends (pigtails, see Figure
2), since this ruins the shielding effect at high frequencies.

If a shielded cable is not used, avoid random lay of unshielded cables in cable
troughs. Using 3-wire plus ground conductor (“green wire”) in a conduit ensures
some degree of noise abatement as the conduit and the green wire carry most of
the return current. However, accidental contact with grid ground structure due to
strap supports, etc. is still a possibility. In contrast, with a shielded cable, this
situation can be avoided by using a PVC outer coating.

In addition to the use of shielded power cable, the following noise reduction
practices are usually employed for control signal wiring practice:
•   Twist the leads to provide a balanced capacitive coupling
•   Use shielded cable to return the noise current flowing in the shield back to
    the source, instead of through the signal leads
•   Maintain at least 8-inch separation between control and power wires in open
    air, conduit or cable trays.
•   Use a common-mode choke wound with multiple turns of both signal and
    shield.
•   Use optical isolation modules for control signal communications




                                          2
EMI Mitigating Devices
Common mode chokes (CMCs) and EMI filters are the two principal mitigating
devices commonly used in VFD application for reducing EMI interference. A
common-mode choke is an inductor with the three-phase conductors wound in
the same direction through a common magnetic core, typically torroidal in shape
(Figure 3). The CMC, when used on VFD output leads provides a high
impedance to any line-to-ground capacitive noise current generated during the
fast transition time of the output voltage waveform. The CMC does not affect the
line-to-line power circuit and takes up less physical space, in contrast with an
output line reactor. The phase-conductor inductance of a line reactor reduces
motor phase voltage, lowering the available motor output torque.

EMI filters for VFD applications are typically structured as low-pass filters with
series inductance and bypass capacitors connected in line-to-ground mode.
These filters are usually installed on the input leads of the VFD. The line-to-
ground by-pass capacitors in the filter provide a low impedance path for the CM
noise currents (Icm in Figure 3) to flow back to the VFD input out of the ground.
The CM and phase inductors or the EMI filter provide high impedance to the
high-frequency noise current. Drive-based equipment that must meet the
European CE conformity must use an EMI/RFI filter connected to the drive input.

European Union Basic EMC Standard Applicable for VFDs
For new installations, end-users can require the VFD vendor to meet applicable
European Union (EU) standards for drives in order to avoid potential EMI
problems. These standards set the allowable emission limits for conducted and
radiated disturbances. Table 1 presents a summary of these emission limits.

•   Standard EN50081-1, Electromagnetic Compatibility Generic Emission
    Standard - Part 1: Residential, Commercial and Light Industrial.
•   Standard EN50081-2, Electromagnetic Compatibility Generic Emission
    Standard - Part 2: Industry.

              Table 1 – Conducted and Radiated Disturbances Limits

Frequency Range                                  Conducted Emissions
                                                    50 kHz - 30 MHz
                           Residential, Commercial, and
                                  Light Industry                           Industry
                        EN 50081-1 and CISPR 22, Class B      EN 50081-2 and CISPR 11, Class A
150 - 500 kHz          56-46 dBµV (Average)                   66 dBµV (Average)
                       66-56 dBµV (Quasi-Peak)                79 dBµV (Quasi-Peak)
0.5 - 5 MHz            46 dBµV (Average)                      60 dBµV (Average)
                       56 dBµV (Quasi-Peak)                   73 dBµV (Quasi-Peak)
5 MHz - 30 MHz         50 dBµV (Average)                      60 dBµV (Average)
                       60 dBµV (Quasi-Peak)                   73 dBµV (Quasi-Peak)

Frequency Range                                  Radiated Emissions
                                                  30 MHz - 1 GHz
30 - 230 MHz           30 dBµV/m @ 10m                     30 dBµV/m @ 10m
230 MHz - 1 GHz        37 dBµV/m @ 10m                     37 dBµV/m @ 10m



                                          3
Figure 1 - Capacitive Coupled Noise Current from Unshielded Phase Conductor of VFD




            Figure 2 – Cable shield bonding: Incorrect (a) and (b) – Correct (c)




                                            4
Figure 3 – Mitigating common mode effects by impeding flow of common mode currents
        with a Common Mode Choke or by providing low-impedance path with an EMI Filter.




Revised: June 2000




                                              5

More Related Content

PPT
02 cdma antenna and feeder system
PPSX
Subsampling Multi-standard receiver design, Part-1
PPTX
Gsm system antenna
PDF
Best abdulmajeed extended_abstract-libre
PDF
2009 IEEE AP-S-Compact Coaxial-Line-Fed Printed Monopole Antenna for Lower-Ba...
PDF
Soluciones de EMC para los retos de la Nueva Directiva
PDF
High_Voltage_RF_LDMOS_Technology_for_Broadcast_Applications_pub
PPT
WIRELESS FM Microphone
02 cdma antenna and feeder system
Subsampling Multi-standard receiver design, Part-1
Gsm system antenna
Best abdulmajeed extended_abstract-libre
2009 IEEE AP-S-Compact Coaxial-Line-Fed Printed Monopole Antenna for Lower-Ba...
Soluciones de EMC para los retos de la Nueva Directiva
High_Voltage_RF_LDMOS_Technology_for_Broadcast_Applications_pub
WIRELESS FM Microphone

What's hot (20)

PDF
Frequency coordination-between-umts-and-gsm-systems-900-mhz
PDF
Frequency coordination between umts and gsm systems at 900 m hz
PDF
Design of microstrip_antenna_and_rf_circ
PPTX
Passive component z versus freq
PDF
2.4GHz 14dbi dual-pol panel wifi antenna
PDF
LDMOS Ruggedness Reliability Microwave Journal
PPT
Radio transmitters
PPTX
T 05 radio recivers
PPT
Transmission media
PDF
Seminario - Würth Elektronik
PPTX
Radio receivers
PPT
04 transmission media
PPT
Modul 6 antenna & related equipments
PPTX
Mobile sniffer
PDF
Rf fundamentals
PDF
HF antennas - HF Antennit
PPT
microwave-systems-1
PDF
Draka - Mobile networks 10-2010 cable products kaapelituotteet
DOCX
Fm radio
Frequency coordination-between-umts-and-gsm-systems-900-mhz
Frequency coordination between umts and gsm systems at 900 m hz
Design of microstrip_antenna_and_rf_circ
Passive component z versus freq
2.4GHz 14dbi dual-pol panel wifi antenna
LDMOS Ruggedness Reliability Microwave Journal
Radio transmitters
T 05 radio recivers
Transmission media
Seminario - Würth Elektronik
Radio receivers
04 transmission media
Modul 6 antenna & related equipments
Mobile sniffer
Rf fundamentals
HF antennas - HF Antennit
microwave-systems-1
Draka - Mobile networks 10-2010 cable products kaapelituotteet
Fm radio
Ad

Viewers also liked (9)

ODT
Reinventing Reading
PDF
Delsa
PPT
Code Camp 06 Model View Presenter Architecture
PPS
2 Sed2 Drive Applications
PDF
E Learning Concept El Yru
DOC
.NET 1.1 Base Page Framework Article
PDF
Evaluating Vfd Cable Parameters
PPTX
Phrasal verbs
PPS
4 Sed2 Harmonics Overview
Reinventing Reading
Delsa
Code Camp 06 Model View Presenter Architecture
2 Sed2 Drive Applications
E Learning Concept El Yru
.NET 1.1 Base Page Framework Article
Evaluating Vfd Cable Parameters
Phrasal verbs
4 Sed2 Harmonics Overview
Ad

Similar to Emi Interference (20)

PDF
EMI Filter and RFI Filters
PDF
Design & Implementation of a Practical EMI Filter for High Frequency-High Pow...
PDF
nguyên tắc cơ bản thiết kế EMC
PPTX
PPT
Electromagnetic Interference and Electromagnetic Compatibility (EMI/EMC
PPS
Linkedin Emc Safety General Info
PPT
PPT
1 IntroductiontoEMIEM-introduction to the semiconductor industry-NEW..ppt
PPT
instroction EMI in industry research in sumilaion
PPT
instroducton EIM in industry commerical in simulation
PDF
Belden Ieee Paper On Vfd Cables
PPTX
Your Power System Failed its Conducted EMI Test – Now What?
PDF
Generaltec power line-en
PPTX
Webinar: Simple Ideas to Make EMI Issues a Thing of the Past
PDF
E0261031035
PDF
E0261031035
PDF
International Journal of Engineering and Science Invention (IJESI)
PDF
EMC for Networks - Peter Thomas, Control Specialists and Jos Knockaert, UGent
PDF
00798333
PDF
Signal and power integrity challenges in VLSI circuits and strategies for the...
EMI Filter and RFI Filters
Design & Implementation of a Practical EMI Filter for High Frequency-High Pow...
nguyên tắc cơ bản thiết kế EMC
Electromagnetic Interference and Electromagnetic Compatibility (EMI/EMC
Linkedin Emc Safety General Info
1 IntroductiontoEMIEM-introduction to the semiconductor industry-NEW..ppt
instroction EMI in industry research in sumilaion
instroducton EIM in industry commerical in simulation
Belden Ieee Paper On Vfd Cables
Your Power System Failed its Conducted EMI Test – Now What?
Generaltec power line-en
Webinar: Simple Ideas to Make EMI Issues a Thing of the Past
E0261031035
E0261031035
International Journal of Engineering and Science Invention (IJESI)
EMC for Networks - Peter Thomas, Control Specialists and Jos Knockaert, UGent
00798333
Signal and power integrity challenges in VLSI circuits and strategies for the...

Emi Interference

  • 1. Pacific Gas and Electric Company Solution of EMI Problems from Operation of Variable-Frequency Drives Background Abrupt voltage transitions on the output terminals of a variable-frequency drive (VFD) are an inherent source of radiated and conducted Electromagnetic Interference (EMI). These voltage transition times are essentially determined by the rise and fall time of the semiconductor devices used in the inverter section of VFDs. The present tendency among drive manufacturers is to use Insulated- Gate-Bipolar-Transistor (IGBTs) devices which have a much lower power loss and higher switching speed than their predecessors Bipolar Junction Transistors (BJTs). However, these improvements result in voltage transition times that can now be as fast as 100 ns and this high dv/dt produces higher magnitude of common- mode (CM) noise currents in the stray line-to-ground capacitance of motor and cables. These CM noise currents can cause electromagnetic interference and affect control signals, encoder feedback, communication links for programmable logic controllers, including RS-232, RS 485, Remote I/O, and different types of sensors including, ultrasonic sensors, bar code/vision systems, weight and temperature sensors. Conducted ground current also leads to radiated emissions, with the drive cables acting as antennas. AM radio reception, radio- controlled operator devices, and television are the most susceptible equipment to this radiated interference from VFDs. The purpose of this Tech Note is to explain the issues related to EMI problems associated with VFD operation, and to provide recommended guidelines for end-users toward mitigating EMI problems related to VFD operation. Problem Description EMI-related problems involve a source of noise, coupling of this noise by conduction or radiation, and circuits/equipment that are susceptible to this noise. The source of noise from VFD operation is the high dv/dt of pulse-width modulated (PWM) output voltage waveforms. As can be seen from Figure 1, the stray capacitance to ground of cables and motors results in high frequency ground currents, the magnitude of which is determined by the equation I = C dv/dt. The high ground impedance at high frequency results in instantaneous voltage differences between two points reputed to be “ground potential.” This voltage appears as a common-mode noise voltage that can interfere with control signals and other communication devices. CM noise may also be capacitively coupled onto control signal cables that are in close proximity of unshielded VFD power leads. Conducted ground currents also lead to radiated interference, with the unshielded phase conductor, the stray capacitance, and the ground return path acting as a loop antenna. With the increasing use of VFDs in commercial and residential applications, the possibility of radio interference from VFDs is an issue 1
  • 2. of concern for end-users. Sometimes this radio interference can affect other customers in the neighborhood of the VFD application. The rise time of the VFD output waveform and the switching frequency of the inverter determine the frequency of the radiated and conducted noise. The switching frequency, which is typically in the range of 1 kHz to 16 kHz, determines the low- frequency conducted noise spectrum. The rise time of modern IGBT inverters can be in the range of 50 ns to 500 ns. This results in a noise frequency fn= 0.318/Trise, respectively 6 MHz to 600 kHz. Preventive Measures to Minimize EMI Problems EMI problems can be minimized to a great degree by adopting preventive measures during the installation phase of VFDs. The most successful preventive measure is to use a shielded power cable to connect the VFD to the motor. This forces the noise current to flow through the shield back to the inverter, before it gets out into the system grid and takes multiple high frequency paths which are difficult to track down in an installation. The use of shielded power cables also reduces the area of the loop antenna that is responsible for radiated interference. The shield should be connected to ground at both ends. It is important to ensure good electrical contact from the installation plate through the installation screws to the metal cabinet of the VFD. Cable clamps should be used instead of twisted shield ends (pigtails, see Figure 2), since this ruins the shielding effect at high frequencies. If a shielded cable is not used, avoid random lay of unshielded cables in cable troughs. Using 3-wire plus ground conductor (“green wire”) in a conduit ensures some degree of noise abatement as the conduit and the green wire carry most of the return current. However, accidental contact with grid ground structure due to strap supports, etc. is still a possibility. In contrast, with a shielded cable, this situation can be avoided by using a PVC outer coating. In addition to the use of shielded power cable, the following noise reduction practices are usually employed for control signal wiring practice: • Twist the leads to provide a balanced capacitive coupling • Use shielded cable to return the noise current flowing in the shield back to the source, instead of through the signal leads • Maintain at least 8-inch separation between control and power wires in open air, conduit or cable trays. • Use a common-mode choke wound with multiple turns of both signal and shield. • Use optical isolation modules for control signal communications 2
  • 3. EMI Mitigating Devices Common mode chokes (CMCs) and EMI filters are the two principal mitigating devices commonly used in VFD application for reducing EMI interference. A common-mode choke is an inductor with the three-phase conductors wound in the same direction through a common magnetic core, typically torroidal in shape (Figure 3). The CMC, when used on VFD output leads provides a high impedance to any line-to-ground capacitive noise current generated during the fast transition time of the output voltage waveform. The CMC does not affect the line-to-line power circuit and takes up less physical space, in contrast with an output line reactor. The phase-conductor inductance of a line reactor reduces motor phase voltage, lowering the available motor output torque. EMI filters for VFD applications are typically structured as low-pass filters with series inductance and bypass capacitors connected in line-to-ground mode. These filters are usually installed on the input leads of the VFD. The line-to- ground by-pass capacitors in the filter provide a low impedance path for the CM noise currents (Icm in Figure 3) to flow back to the VFD input out of the ground. The CM and phase inductors or the EMI filter provide high impedance to the high-frequency noise current. Drive-based equipment that must meet the European CE conformity must use an EMI/RFI filter connected to the drive input. European Union Basic EMC Standard Applicable for VFDs For new installations, end-users can require the VFD vendor to meet applicable European Union (EU) standards for drives in order to avoid potential EMI problems. These standards set the allowable emission limits for conducted and radiated disturbances. Table 1 presents a summary of these emission limits. • Standard EN50081-1, Electromagnetic Compatibility Generic Emission Standard - Part 1: Residential, Commercial and Light Industrial. • Standard EN50081-2, Electromagnetic Compatibility Generic Emission Standard - Part 2: Industry. Table 1 – Conducted and Radiated Disturbances Limits Frequency Range Conducted Emissions 50 kHz - 30 MHz Residential, Commercial, and Light Industry Industry EN 50081-1 and CISPR 22, Class B EN 50081-2 and CISPR 11, Class A 150 - 500 kHz 56-46 dBµV (Average) 66 dBµV (Average) 66-56 dBµV (Quasi-Peak) 79 dBµV (Quasi-Peak) 0.5 - 5 MHz 46 dBµV (Average) 60 dBµV (Average) 56 dBµV (Quasi-Peak) 73 dBµV (Quasi-Peak) 5 MHz - 30 MHz 50 dBµV (Average) 60 dBµV (Average) 60 dBµV (Quasi-Peak) 73 dBµV (Quasi-Peak) Frequency Range Radiated Emissions 30 MHz - 1 GHz 30 - 230 MHz 30 dBµV/m @ 10m 30 dBµV/m @ 10m 230 MHz - 1 GHz 37 dBµV/m @ 10m 37 dBµV/m @ 10m 3
  • 4. Figure 1 - Capacitive Coupled Noise Current from Unshielded Phase Conductor of VFD Figure 2 – Cable shield bonding: Incorrect (a) and (b) – Correct (c) 4
  • 5. Figure 3 – Mitigating common mode effects by impeding flow of common mode currents with a Common Mode Choke or by providing low-impedance path with an EMI Filter. Revised: June 2000 5