SlideShare a Scribd company logo
Material Characterization
Gas Pycnometry
“Pycnometry”
• Is a Greek word “puknos” meana to measure the density and volume.
• It is Reliable and absolute method of measuring.
• Based on Boyle’s law (volume-pressure relationship).
• Regularly shaped, granular, powder, porous and non-porous samples can
be used.
• Gas pycnometers also called Helium pycnometers.
• A gas displacement method for measuring the volume.
• It can be performed in less than 20 minutes.
Gas Pycnometry
Principle of operation:
1. valve a opens and
2. Inert gas flows into the sample chamber
3. On seeing equilibrium is reached
4. valve b opens and
Gas flows into second
chamber for volume measurement
4. Again equilibrium is reached
5. Sample weight divided by Volume determines the density.
6. Then valve c is openend and pressure vented off to open atmosphere.
Gas Pycnometry
Kinds of pycnometers:
1. Constant-volume pycnometer
2. Variable-volume pycnometer
3. Comparative pycnometer
• Constant-volume pycnometer
1. Valves are opened, sample is placed into the sample chamber, and
pycnometer is filled with gas.
2. There is a absolute pressure transducer for measuring the initial gas
pressure in the pycnometer (Pi), while closing the valve “M”.
Gas Pycnometry
3. To separate the sample chamber from tank valve “Z” is closed and valve
“M”
is opened and some gas is sent into the tank.
4. Now valve “M” is closed and gas pressure in the
tank is measured (Pj); and
5. On opening the valve “Z” gas
will expand from the tank to the sample chamber (or vice versa), when
the gas expansion is completed, then final gas pressure is measured (Pf).
Vs= V ◦c + V◦t τ τ =Pf − Pj /Pf − Pi
Gas Pycnometry
Gas Pycnometry
• Variable-volume pycnometer
1. Now sample is placed in the sample chamber, and piston is
placed at an initial position
2. Opening the valve, and fill the pycnometer with gas.
3. Close the valve and measure the initial gas pressure in the
pycnometer (Pi) with the help of absolute pressure transducer.
4. For measuring the final pressure (Pf), the piston is moved to
another position.
Vs= V ◦c + V◦pτ τ = - [Pmin / Pmax – Pmin]
Gas Pycnometry
Gas Pycnometry
• Comparative pycnometer
1. The piston chamber and the volume controller are set such as their
internal volume is minimum, the sample is placed in the chamber,
open the valve, and fill the pycnometer with gas.
2. Close the valve so that there is no difference in the gas pressures in
the sample chamber and the tank.
3. Pulled the piston is to a maximum position.
4. And then adjust the volume controller, again to see that there is no
difference in the gas pressures of sample chamber and the tank.
Gas Pycnometry
5. The internal volume of the volume controller (Vr) can be determined.
Vs = Vc − (Vt /Vp)Vr
Gas Pycnometry
Equipments available:-
Gas Pycnometry
Advantages
• Simple method
• Relatively inexpensive instrument
• Fastness
• Less manpower necessary
• Adjustable gas flow rates
• Easy to read digital display
• Non-destructive technique
Gas Pycnometry
Disadvantages
• In some cases, they are expensive. (on industrial scale)
• Not suitable for expensive samples because large sample volumes are
required
• Difficult to clean and dry
Applications
• Used for characterizing catalysts, carbons, metal powders, soils,
ceramics, pharmaceutical ingredients, petroleum coke, cement,
cosmetics etc.
• Density of viscous materials can also be determined.
Gas Pycnometry
Article:- Use of gas pycnometry for estimating the iron content in mineral
samples.
• Hematite iron ore
• Helium gas pycnometry (The helium gas pycnometer is typically consists
of two chambers of known volumes that are connected by an expansion
valve. One chamber is used where sample is placed, and the other is
used where the gas expansion happens.)
• Vca = Sample chamber volume, Vce = Expansion chamber volume, and Vs =
Volume of the solid(sample).
Gas Pycnometry
• Only hematite (Fe2O3) and quartz (SiO2) were assumed to be present
in the sample, rest of components (especially Al2O3, CaO, K2O, and
MgO) represented less than 5% by weight of most of the studied
samples.
• Thus, the mass of hematite (mhe) plus the mass of quartz (msi) results
in the solid mass of the sample (ms) as follows:
mhe+msi = ms
• The total volume of the solid sample is a volumetric fraction ϕ
Gas Pycnometry
• Because the hematite mass fraction (fhe), which is fhe = mhe/ms
• m=ρ∗V so,
• specific gravities of the pure constituents (ρhe = 5.2 g/cm3 and
ρsi = 2.65 g/cm3) and the mean density of the sample obtained
experimentally by helium gas pycnometry.
• Fe(%)=0.70⋅fh⋅100
• The factor 0.70 shows the Fe fraction present in hematite ore.
Gas Pycnometry
Sample ρs (g/cm3)
Fe2O3 (%) –
Pic Fe (%) – Pic Fe (%) – CA
Absolute
difference
1 4.1916 75.0 52.5 48.6 −3.9
2 3.6079 54.1 37.9 34.1 −3.8
3 3.9019 65.4 45.8 43.90 −1.9
4 3.5671 52.4 36.7 33.8 −2.9
5 4.2244 76.0 53.2 50.4 −2.8
6 4.3911 80.9 56.6 53.90 −2.7
7 3.0446 26.4 18.5 17.20 −1.3
8 2.9473 20.6 14.4 12.2 −2.2
9 3.0495 26.7 18.7 16.2 −2.5
10 2.7303 6.0 4.2 2.49 −1.7
Table 1.
Comparison of the Fe contents estimated by pycnometry [Fe(%) – Pic] and those obtained by chemical analysis [Fe(%) – CA].
Gas Pycnometry
Gas pycnometry

More Related Content

PPTX
Aniline point - petroleum - UOS
PDF
Carbon dioxide Industries
PDF
Determination of Aniline Point of Petroleum Samples
PPT
Cracking
DOCX
Aniline point determination by-diar ismail
PDF
Pour point
PPTX
Thermal cracking
PPTX
AZEOTROPIC DISTILLATION
Aniline point - petroleum - UOS
Carbon dioxide Industries
Determination of Aniline Point of Petroleum Samples
Cracking
Aniline point determination by-diar ismail
Pour point
Thermal cracking
AZEOTROPIC DISTILLATION

What's hot (20)

PPT
Catalytic reforming process
PPTX
Desulfurization 2
PPT
Api Gravity
PPTX
Phosphoric acid [CHEMICAL PROCESSS INDUSTRIES]
PPTX
Vacuum distillation
PPTX
Raw material for Polymers
PPTX
Aniline point for petroleum productes
PDF
Origin and Composition of Crude Oil.pdf
PPTX
Visbreaking and Delayed coking
PDF
Standard Test For Ash From Petroleum Products , D482
PPT
Treatment of crude oils
PPTX
Crabon black ccil.ppt
PDF
Particle technology Lab report
PPTX
Fluidized cataltic cracking.
PPTX
Thermogravimetric analysis - Pharmaceutical analysis
PPT
Polymerization techniques
PDF
Sulphur spurrite-and-rings-in-cement-kilns-pdf
PPTX
Multi Effect Evaporators
DOCX
Smoke point
PPTX
FLUID COKING
Catalytic reforming process
Desulfurization 2
Api Gravity
Phosphoric acid [CHEMICAL PROCESSS INDUSTRIES]
Vacuum distillation
Raw material for Polymers
Aniline point for petroleum productes
Origin and Composition of Crude Oil.pdf
Visbreaking and Delayed coking
Standard Test For Ash From Petroleum Products , D482
Treatment of crude oils
Crabon black ccil.ppt
Particle technology Lab report
Fluidized cataltic cracking.
Thermogravimetric analysis - Pharmaceutical analysis
Polymerization techniques
Sulphur spurrite-and-rings-in-cement-kilns-pdf
Multi Effect Evaporators
Smoke point
FLUID COKING
Ad

Similar to Gas pycnometry (20)

PPTX
Pycnomatic presentation
PDF
Measurement of temperature, flow, pressure
PDF
Measurement techniques covering all methods
PPTX
Measuring INSTRUMENTS
PPTX
Methods of temperature measurement & discussion
DOCX
Bellevue College Chemistry 162 1 Empirical Gas La.docx
PPTX
Types of Industrial Process Analyzers
PPTX
Miscellaneos analysis
PPTX
Tempreture measurement
PPTX
Density measurement
PPTX
Physics slideshow
PDF
Density_Measurement_Analytical_Instrumentation..pdf
PPTX
PMI M.Sc.Thesis Research presentation ppt.pptx
PDF
Gas Sensing and Monitoring
PDF
Blood gas analyser & blood gas analysis with clinical significancee
PPTX
Blood Gas Analysers detailed explanation
DOCX
PPTX
Basic concepts of Temperature Measurement
PDF
Chapter10.pdf
PPTX
619146781-coulometry and the techniques involved in it.pptx
Pycnomatic presentation
Measurement of temperature, flow, pressure
Measurement techniques covering all methods
Measuring INSTRUMENTS
Methods of temperature measurement & discussion
Bellevue College Chemistry 162 1 Empirical Gas La.docx
Types of Industrial Process Analyzers
Miscellaneos analysis
Tempreture measurement
Density measurement
Physics slideshow
Density_Measurement_Analytical_Instrumentation..pdf
PMI M.Sc.Thesis Research presentation ppt.pptx
Gas Sensing and Monitoring
Blood gas analyser & blood gas analysis with clinical significancee
Blood Gas Analysers detailed explanation
Basic concepts of Temperature Measurement
Chapter10.pdf
619146781-coulometry and the techniques involved in it.pptx
Ad

Recently uploaded (20)

PPTX
Current and future trends in Computer Vision.pptx
PPTX
CYBER-CRIMES AND SECURITY A guide to understanding
PPTX
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
PPTX
CH1 Production IntroductoryConcepts.pptx
PDF
PPT on Performance Review to get promotions
PPTX
OOP with Java - Java Introduction (Basics)
PDF
The CXO Playbook 2025 – Future-Ready Strategies for C-Suite Leaders Cerebrai...
PPTX
additive manufacturing of ss316l using mig welding
PDF
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf
PDF
PREDICTION OF DIABETES FROM ELECTRONIC HEALTH RECORDS
PPTX
bas. eng. economics group 4 presentation 1.pptx
DOCX
ASol_English-Language-Literature-Set-1-27-02-2023-converted.docx
PDF
Mitigating Risks through Effective Management for Enhancing Organizational Pe...
PPTX
web development for engineering and engineering
PPTX
UNIT 4 Total Quality Management .pptx
PDF
Operating System & Kernel Study Guide-1 - converted.pdf
PPTX
Geodesy 1.pptx...............................................
PDF
SM_6th-Sem__Cse_Internet-of-Things.pdf IOT
PDF
Evaluating the Democratization of the Turkish Armed Forces from a Normative P...
PDF
TFEC-4-2020-Design-Guide-for-Timber-Roof-Trusses.pdf
Current and future trends in Computer Vision.pptx
CYBER-CRIMES AND SECURITY A guide to understanding
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
CH1 Production IntroductoryConcepts.pptx
PPT on Performance Review to get promotions
OOP with Java - Java Introduction (Basics)
The CXO Playbook 2025 – Future-Ready Strategies for C-Suite Leaders Cerebrai...
additive manufacturing of ss316l using mig welding
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf
PREDICTION OF DIABETES FROM ELECTRONIC HEALTH RECORDS
bas. eng. economics group 4 presentation 1.pptx
ASol_English-Language-Literature-Set-1-27-02-2023-converted.docx
Mitigating Risks through Effective Management for Enhancing Organizational Pe...
web development for engineering and engineering
UNIT 4 Total Quality Management .pptx
Operating System & Kernel Study Guide-1 - converted.pdf
Geodesy 1.pptx...............................................
SM_6th-Sem__Cse_Internet-of-Things.pdf IOT
Evaluating the Democratization of the Turkish Armed Forces from a Normative P...
TFEC-4-2020-Design-Guide-for-Timber-Roof-Trusses.pdf

Gas pycnometry

  • 2. Gas Pycnometry “Pycnometry” • Is a Greek word “puknos” meana to measure the density and volume. • It is Reliable and absolute method of measuring. • Based on Boyle’s law (volume-pressure relationship). • Regularly shaped, granular, powder, porous and non-porous samples can be used. • Gas pycnometers also called Helium pycnometers. • A gas displacement method for measuring the volume. • It can be performed in less than 20 minutes.
  • 3. Gas Pycnometry Principle of operation: 1. valve a opens and 2. Inert gas flows into the sample chamber 3. On seeing equilibrium is reached 4. valve b opens and Gas flows into second chamber for volume measurement 4. Again equilibrium is reached 5. Sample weight divided by Volume determines the density. 6. Then valve c is openend and pressure vented off to open atmosphere.
  • 4. Gas Pycnometry Kinds of pycnometers: 1. Constant-volume pycnometer 2. Variable-volume pycnometer 3. Comparative pycnometer • Constant-volume pycnometer 1. Valves are opened, sample is placed into the sample chamber, and pycnometer is filled with gas. 2. There is a absolute pressure transducer for measuring the initial gas pressure in the pycnometer (Pi), while closing the valve “M”.
  • 5. Gas Pycnometry 3. To separate the sample chamber from tank valve “Z” is closed and valve “M” is opened and some gas is sent into the tank. 4. Now valve “M” is closed and gas pressure in the tank is measured (Pj); and 5. On opening the valve “Z” gas will expand from the tank to the sample chamber (or vice versa), when the gas expansion is completed, then final gas pressure is measured (Pf). Vs= V ◦c + V◦t τ τ =Pf − Pj /Pf − Pi
  • 7. Gas Pycnometry • Variable-volume pycnometer 1. Now sample is placed in the sample chamber, and piston is placed at an initial position 2. Opening the valve, and fill the pycnometer with gas. 3. Close the valve and measure the initial gas pressure in the pycnometer (Pi) with the help of absolute pressure transducer. 4. For measuring the final pressure (Pf), the piston is moved to another position. Vs= V ◦c + V◦pτ τ = - [Pmin / Pmax – Pmin]
  • 9. Gas Pycnometry • Comparative pycnometer 1. The piston chamber and the volume controller are set such as their internal volume is minimum, the sample is placed in the chamber, open the valve, and fill the pycnometer with gas. 2. Close the valve so that there is no difference in the gas pressures in the sample chamber and the tank. 3. Pulled the piston is to a maximum position. 4. And then adjust the volume controller, again to see that there is no difference in the gas pressures of sample chamber and the tank.
  • 10. Gas Pycnometry 5. The internal volume of the volume controller (Vr) can be determined. Vs = Vc − (Vt /Vp)Vr
  • 12. Gas Pycnometry Advantages • Simple method • Relatively inexpensive instrument • Fastness • Less manpower necessary • Adjustable gas flow rates • Easy to read digital display • Non-destructive technique
  • 13. Gas Pycnometry Disadvantages • In some cases, they are expensive. (on industrial scale) • Not suitable for expensive samples because large sample volumes are required • Difficult to clean and dry Applications • Used for characterizing catalysts, carbons, metal powders, soils, ceramics, pharmaceutical ingredients, petroleum coke, cement, cosmetics etc. • Density of viscous materials can also be determined.
  • 14. Gas Pycnometry Article:- Use of gas pycnometry for estimating the iron content in mineral samples. • Hematite iron ore • Helium gas pycnometry (The helium gas pycnometer is typically consists of two chambers of known volumes that are connected by an expansion valve. One chamber is used where sample is placed, and the other is used where the gas expansion happens.) • Vca = Sample chamber volume, Vce = Expansion chamber volume, and Vs = Volume of the solid(sample).
  • 15. Gas Pycnometry • Only hematite (Fe2O3) and quartz (SiO2) were assumed to be present in the sample, rest of components (especially Al2O3, CaO, K2O, and MgO) represented less than 5% by weight of most of the studied samples. • Thus, the mass of hematite (mhe) plus the mass of quartz (msi) results in the solid mass of the sample (ms) as follows: mhe+msi = ms • The total volume of the solid sample is a volumetric fraction ϕ
  • 16. Gas Pycnometry • Because the hematite mass fraction (fhe), which is fhe = mhe/ms • m=ρ∗V so, • specific gravities of the pure constituents (ρhe = 5.2 g/cm3 and ρsi = 2.65 g/cm3) and the mean density of the sample obtained experimentally by helium gas pycnometry. • Fe(%)=0.70⋅fh⋅100 • The factor 0.70 shows the Fe fraction present in hematite ore.
  • 17. Gas Pycnometry Sample ρs (g/cm3) Fe2O3 (%) – Pic Fe (%) – Pic Fe (%) – CA Absolute difference 1 4.1916 75.0 52.5 48.6 −3.9 2 3.6079 54.1 37.9 34.1 −3.8 3 3.9019 65.4 45.8 43.90 −1.9 4 3.5671 52.4 36.7 33.8 −2.9 5 4.2244 76.0 53.2 50.4 −2.8 6 4.3911 80.9 56.6 53.90 −2.7 7 3.0446 26.4 18.5 17.20 −1.3 8 2.9473 20.6 14.4 12.2 −2.2 9 3.0495 26.7 18.7 16.2 −2.5 10 2.7303 6.0 4.2 2.49 −1.7 Table 1. Comparison of the Fe contents estimated by pycnometry [Fe(%) – Pic] and those obtained by chemical analysis [Fe(%) – CA].