SlideShare a Scribd company logo
HIGH FREQUENCY CURRENT
DR.AYESHA BHATTI
BSPT(K.E.M.U) PP.DPT(RCRS)
HIGH FREQUENCY CURRENT:
High frequency current is a current which alternates so rapidly that it
doesn’t stimulate motor or sensory nerves.
To achieve this it must have the frequency of more than approximately
more than 500,000 cycles/sec and it is often termed as oscillating
current.
An oscillation may be defined as a swinging to and fro.
A high frequency alternating current is described as an oscillating
current, because the electrons swing to and fro in the circuit and
behavior of an oscillating current in many ways resembles that of other
oscillating systems.
PRODUCTION OF HIGH FREQUENCY CURRENT:
The valve is a device which transmits in one direction only, common
example being the valve of heart, veins and that of bicycle tyre .
A thermionic valve is a device which transmits an electric current in one
direction only, and the term thermionic implies that heat plays some
part in the working.
There are various types of thermionic valve which are named according
to the number of electrodes that they contain.
THE DIODE VALVES:
This is the simplest form of thermionic valve, and contains two
electrodes. The filament and the plate which are enclosed in evacuated
glass bulb. For a current to pass across the valve the filament must be
heated and a p.d(potential difference) applied, so that the plate is
positive in relation to the filament. When the filament is heated
thermionic emission to the filament, the free electrons are attracted
through the vacuum to the plate and current passes across the valve.
High frequency current
if P.d is reversed so that the plate is negative relative to the filament, as
there are no free electrons in the region of plate.
Thus electron can pass from the filament to the plate, but not in reverse
direction, and the valve transmits current in one direction only.
The pressure in the valve must be low so that there is minimal
impedance to the electron movement.
The intensity of the current that flows across the valve depends on
heating of filament and on p.d the filament and the plate.
Increasing the former increases the number of electrons that are
liberated and increase in p.d makes available the greater force to attract
them across the valve.
The filament is heated by an electric current and circuit which carries
this current is known as the filament circuit.
This circuit which carries the current which passes across the valve is
termed the plate or anode circuit.
The filament may be heated directly by passing the electric current
through it or may be of the indirectly heated type.
The later takes rather longer to reach the necessary temperature and
there is some delay after switching on before the valve begins to
transmit current.
THE TRIODE VALVE:
This is constructed in a similar manner to the diode,, but in addition
contains a third electrode, the grid, which is placed b/w the filament
and the plate.
The grid may consists of Mattel plate perforated to allow the electrons
to pass through, or, more usually, may be a coil of wire.
When the filament is heated a current can be passed through the valve.
As in the diode, in one direction only i.e. from the filament to the plate.
If The grid is uncharged it has no effect on the current, that the electron
pass through the opening in it and on to the anode, if the grid is charges
negatively from some outside source, it repels electrons, so that the
current is reduced on intensity, with the stronger charge stopped
completely.
If, however, the grid is charged positively the electrons can pass and
current flows. The intensity of the current is then greater than when the
grid id uncharged, as positive electrons away from the filament.
Most of these pass through the grid and on to the anode.
Triode symbol. From top
to bottom: plate (anode),
control grid, cathode,
heater (filament)
The charge is applied to the grid from an external source are known as
grid biased and, as the grid lies closer to the filament than does the
plate, the grid charged has a greater influence on the flow of current
than has a similar charge on the anode.
The strength of the current going across the valve can be regulated, as in
the diode, by altering the temperature of the filament or by altering the
positive charge applied to the anode.
In addition, the flow of current across the triode valve can be regulated
by adjusting the biased of the grid.
The triode valve has various functions in electrometrical apparatus, the
principle ones being its used for the production of the interrupted direct
and other muscle stimulation currents and, in conjunction with a
condenser and an inductance, for the production of high frequency
currents.
It is not used specifically as a rectifier, but will always rectify the current
that passes through it.
TRANSISTORS
– (bipolar) transistor = combination of two diodes that share
middle portion, called “base” of transistor; other two
sections: “emitter'' and “collector”;
– usually, base is very thin and lightly doped.
– two kinds of bipolar transistors: pnp and npn transistors
– “pnp” means emitter is p-type, base is n-type, and collector
is p-type material;
– in “normal operation of pnp transistor, apply positive
voltage to emitter, negative voltage to collector;
Fig
operation of pnp transistor:
operation of pnp transistor:
– if emitter-base junction is forward biased, “holes
flow” from battery into emitter, move into base;
– some holes annihilate with electrons in n-type
base, but base thin and lightly doped  most holes
make it through base into collector,
– holes move through collector into negative
terminal of battery; i.e. “collector current” flows
whose size depends on how many holes have been
captured by electrons in the base;
operation of pnp transistor:
• this depends on the number of n-type carriers in the base
which can be controlled by the size of the current (the “base
current”) that is allowed to flow from the base to the emitter;
the base current is usually very small; small changes in the
base current can cause a big difference in the collector current
Transistor operation
– transistor acts as amplifier of base current,
since small changes in base current cause big
changes in collector current.
– transistor as switch: if voltage applied to base is
such that emitter-base junction is reverse-biased,
no current flows through transistor -- transistor is
“off”
– therefore, a transistor can be used as a voltage-
controlled switch; computers use transistors in this
way.
What is DIATHERMY?
• The use of non-ionizing electromagnetic
energy from the radio-frequency spectrum
as therapeutic agent
Types of Diathermy
Long wave
- longest wavelength 300 – 30 m
- most penetrating
- no longer utilized due to high potential of
causing burns and interference with radio
transmissions
Shortwave
Microwave
PRODUCTION OF HIGH FREQUECHY SHORT WAVES:
High frequency electromagnetic waves of frequency b/w 107 or 108 and
a wavelength b/w 30-3 m to generate heat in body tissues.
therapeutically used and available f=27.12MHz and λ=11m commonly.
It is not possible to construct any mechanical device which causes
sufficient rapid movement to produce high frequency current so this
type of current is obtained by discharging a condenser through an
inductance of low ohmic resistance.
The basic oscillator circuit consists of a condenser and an inductance
and current of different frequencies are obtained by selecting suitable
condensers and inductances.
If a current of high frequency is required the capacity and inductance
are small, while to produce a current of lower frequency a larger
condenser and/or inductance are used.
Basic oscillator circuit is now a days frequently replaced by a more
modern oscillator such as co-axial line or pot oscillator but the principle
remain same.
In order to produce high frequency current the condenser must be
made to charge and discharge repeatedly and to achieve this the
oscillator is incorporated in either a spark gap or a valve circuit, the
latter being commonly used in apparatus encountered in physiotherapy
department. In future transistor may replace the triode valve.
The high frequency current is produced in the basic oscillator which is
incorporated in anode circuit of triode valve.
This current produces a similar high frequency current in a second
circuit, the resonator circuit by electromagnetic induction and by action
of wireless waves.
It is the current from this second circuit, which is used for the treatment
of patients and for the production of oscillator and a resonator circuits
must be in a resonance with each other.
For this to occur the product of inductance and capacity must be same
for both circuits.
MICRO WAVE PRODUCTION:
Microwave diathermy can be defined as Use of microwave for various
therapeutic purposes. Microwave has much higher frequency and a
shorter wavelength than short wave diathermy.
The frequency and wavelength ranges from 300 MHz TO 300 GHz and
1cm to 1m.
The commonly used frequency are 2456 MHz, 915 MHz and 433 MHz
with a wavelength 12.24 cm ,32.79cm and 69cm respectively.
PRODUCTION OF MICROWAVES:
The microwave circuit is connected to the main AC which provides it a
current of 50 Hz and a voltage of 220volts.
It is not possible to produce microwaves by mechanical means and
hence a special type of thermionic valve is used called magnetron.
The primary function of magnetron is to produce high frequency current
required for he production of microwaves.
Magnetron is special type of thermionic valve characterized by centrally
placed cathode and a surrounding circular metal anode.
MICROWAVE DIATHERMY APPARATUS
Coaxial cables carries this high frequency currents from the magnetron
and passes it to the antenna of emitter.
Emitter is also known as director or applicator consists of antenna and a
reflector.
Antenna is mounted in front of a metal reflector. Reflector is a metal
plate which directs the microwaves in on direction only.
The distance b/w the emitter and skin should be about 10-20 cms from
the body.
However vary according to size of emitter , the part to be treated and
condition of patient.
THERAPEUTIC EFFECTS
• Increased blood flow or circulation to the
area
• Increased tissue temperature
• Increased metabolism
• Facilitate relaxation
• Increased pain threshold
• Decreased blood viscosity
INDICATIONS
• Soft tissue injury
• Mobilization
• Pain relief
CONTRAINDICATIONS
• Pacemakers
• Metal implants
• Impaired
sensation
• Pregnancy
• Hemorrhage
• Ischemic Tissue
• Testicles and eyes
• Malignant CA
• Active TB
• Fever
• Thrombosis
• X-ray exposure
• Uncooperative
patient
• Areas of poor
circulation
THANKS

More Related Content

PPTX
Shortwave diathermy
PPTX
Low Frequency Therapeutic Currents
PPTX
Effect of exercise on cardiovascular system
PPTX
Superimposed currents
PPTX
Pain : definition, assessment, types, scales, physiotherapy management
PPTX
SD curve (Strength Duration Curve)
PPTX
Suspension therapy
PPTX
Incontinence bowel and bladder
Shortwave diathermy
Low Frequency Therapeutic Currents
Effect of exercise on cardiovascular system
Superimposed currents
Pain : definition, assessment, types, scales, physiotherapy management
SD curve (Strength Duration Curve)
Suspension therapy
Incontinence bowel and bladder

What's hot (20)

PPTX
Sinusoidal current 2
PPTX
Constant galvanic current
PPT
Introduction to micro current
PPTX
High voltage pulsed galvanic
PPTX
FARADIC CURRENT.pptx
PPTX
Russian current
PPTX
Sinusoidal current
PPTX
Types of electrotherapeutic current
PPT
Ultraviolet radiation in Physiotherapy
PPTX
Low Frequency Currents SRS
PPTX
Short wave diathermy (s.w.d) electro therapy
PPTX
Interferential current
PPTX
Contrast bath SRS
PPT
Rebox current
PPTX
High voltage pulsed galvanic stimulation
PPTX
Electrotherapy intro.. 5 th semester
PPTX
PPTX
Modified galvanic current
PPTX
Electrical stimulation
PPTX
Interrupted direct current
Sinusoidal current 2
Constant galvanic current
Introduction to micro current
High voltage pulsed galvanic
FARADIC CURRENT.pptx
Russian current
Sinusoidal current
Types of electrotherapeutic current
Ultraviolet radiation in Physiotherapy
Low Frequency Currents SRS
Short wave diathermy (s.w.d) electro therapy
Interferential current
Contrast bath SRS
Rebox current
High voltage pulsed galvanic stimulation
Electrotherapy intro.. 5 th semester
Modified galvanic current
Electrical stimulation
Interrupted direct current
Ad

Similar to High frequency current (20)

PDF
X ray generator
PPTX
Short wave diathermy.pptx
PDF
Electricity,.pdf
PPTX
Electricity1,corrected.pptx
PPT
X ray Generator physics behind x ray generation.ppt
PPTX
High direct current measurement
PPTX
X ray generators
PPTX
X-Ray Generators.pptx
PPTX
Current Electricity- Dr. Diksha Gondkar, MPT (Neuro)
PPT
clap switch.ppt
PPTX
6. HIGH FREQUENCY GENERATIORS AND RECTIFICATION.pptx by Ravindra Kumar.pptx
PPTX
ELECTRICITY (1).pptx
PPTX
Electro presentation
PDF
1 basic electronics
PPTX
Introduction of electricity
PPTX
Linac presentation
PPTX
"high tension generator", "high tension","tension generator", "generator", ...
PPTX
Linear Accelerators.pptx
PDF
Wirless Power Transmission
PPTX
circuit diagram.pptx
X ray generator
Short wave diathermy.pptx
Electricity,.pdf
Electricity1,corrected.pptx
X ray Generator physics behind x ray generation.ppt
High direct current measurement
X ray generators
X-Ray Generators.pptx
Current Electricity- Dr. Diksha Gondkar, MPT (Neuro)
clap switch.ppt
6. HIGH FREQUENCY GENERATIORS AND RECTIFICATION.pptx by Ravindra Kumar.pptx
ELECTRICITY (1).pptx
Electro presentation
1 basic electronics
Introduction of electricity
Linac presentation
"high tension generator", "high tension","tension generator", "generator", ...
Linear Accelerators.pptx
Wirless Power Transmission
circuit diagram.pptx
Ad

Recently uploaded (20)

PDF
CAPERS-LRD-z9:AGas-enshroudedLittleRedDotHostingaBroad-lineActive GalacticNuc...
PPTX
ECG_Course_Presentation د.محمد صقران ppt
PDF
The scientific heritage No 166 (166) (2025)
PDF
Placing the Near-Earth Object Impact Probability in Context
PDF
SEHH2274 Organic Chemistry Notes 1 Structure and Bonding.pdf
PPT
protein biochemistry.ppt for university classes
PDF
Cosmic Outliers: Low-spin Halos Explain the Abundance, Compactness, and Redsh...
PPTX
cpcsea ppt.pptxssssssssssssssjjdjdndndddd
PPTX
2. Earth - The Living Planet Module 2ELS
PDF
ELS_Q1_Module-11_Formation-of-Rock-Layers_v2.pdf
PPTX
7. General Toxicologyfor clinical phrmacy.pptx
PPTX
neck nodes and dissection types and lymph nodes levels
PPTX
TOTAL hIP ARTHROPLASTY Presentation.pptx
PPTX
Derivatives of integument scales, beaks, horns,.pptx
PDF
AlphaEarth Foundations and the Satellite Embedding dataset
PDF
Formation of Supersonic Turbulence in the Primordial Star-forming Cloud
PPTX
Introduction to Fisheries Biotechnology_Lesson 1.pptx
PPTX
The KM-GBF monitoring framework – status & key messages.pptx
PPTX
ANEMIA WITH LEUKOPENIA MDS 07_25.pptx htggtftgt fredrctvg
PPTX
DRUG THERAPY FOR SHOCK gjjjgfhhhhh.pptx.
CAPERS-LRD-z9:AGas-enshroudedLittleRedDotHostingaBroad-lineActive GalacticNuc...
ECG_Course_Presentation د.محمد صقران ppt
The scientific heritage No 166 (166) (2025)
Placing the Near-Earth Object Impact Probability in Context
SEHH2274 Organic Chemistry Notes 1 Structure and Bonding.pdf
protein biochemistry.ppt for university classes
Cosmic Outliers: Low-spin Halos Explain the Abundance, Compactness, and Redsh...
cpcsea ppt.pptxssssssssssssssjjdjdndndddd
2. Earth - The Living Planet Module 2ELS
ELS_Q1_Module-11_Formation-of-Rock-Layers_v2.pdf
7. General Toxicologyfor clinical phrmacy.pptx
neck nodes and dissection types and lymph nodes levels
TOTAL hIP ARTHROPLASTY Presentation.pptx
Derivatives of integument scales, beaks, horns,.pptx
AlphaEarth Foundations and the Satellite Embedding dataset
Formation of Supersonic Turbulence in the Primordial Star-forming Cloud
Introduction to Fisheries Biotechnology_Lesson 1.pptx
The KM-GBF monitoring framework – status & key messages.pptx
ANEMIA WITH LEUKOPENIA MDS 07_25.pptx htggtftgt fredrctvg
DRUG THERAPY FOR SHOCK gjjjgfhhhhh.pptx.

High frequency current

  • 1. HIGH FREQUENCY CURRENT DR.AYESHA BHATTI BSPT(K.E.M.U) PP.DPT(RCRS)
  • 2. HIGH FREQUENCY CURRENT: High frequency current is a current which alternates so rapidly that it doesn’t stimulate motor or sensory nerves. To achieve this it must have the frequency of more than approximately more than 500,000 cycles/sec and it is often termed as oscillating current. An oscillation may be defined as a swinging to and fro. A high frequency alternating current is described as an oscillating current, because the electrons swing to and fro in the circuit and behavior of an oscillating current in many ways resembles that of other oscillating systems.
  • 3. PRODUCTION OF HIGH FREQUENCY CURRENT: The valve is a device which transmits in one direction only, common example being the valve of heart, veins and that of bicycle tyre . A thermionic valve is a device which transmits an electric current in one direction only, and the term thermionic implies that heat plays some part in the working. There are various types of thermionic valve which are named according to the number of electrodes that they contain. THE DIODE VALVES: This is the simplest form of thermionic valve, and contains two electrodes. The filament and the plate which are enclosed in evacuated glass bulb. For a current to pass across the valve the filament must be heated and a p.d(potential difference) applied, so that the plate is positive in relation to the filament. When the filament is heated thermionic emission to the filament, the free electrons are attracted through the vacuum to the plate and current passes across the valve.
  • 5. if P.d is reversed so that the plate is negative relative to the filament, as there are no free electrons in the region of plate. Thus electron can pass from the filament to the plate, but not in reverse direction, and the valve transmits current in one direction only. The pressure in the valve must be low so that there is minimal impedance to the electron movement. The intensity of the current that flows across the valve depends on heating of filament and on p.d the filament and the plate. Increasing the former increases the number of electrons that are liberated and increase in p.d makes available the greater force to attract them across the valve.
  • 6. The filament is heated by an electric current and circuit which carries this current is known as the filament circuit. This circuit which carries the current which passes across the valve is termed the plate or anode circuit. The filament may be heated directly by passing the electric current through it or may be of the indirectly heated type. The later takes rather longer to reach the necessary temperature and there is some delay after switching on before the valve begins to transmit current.
  • 7. THE TRIODE VALVE: This is constructed in a similar manner to the diode,, but in addition contains a third electrode, the grid, which is placed b/w the filament and the plate. The grid may consists of Mattel plate perforated to allow the electrons to pass through, or, more usually, may be a coil of wire. When the filament is heated a current can be passed through the valve. As in the diode, in one direction only i.e. from the filament to the plate. If The grid is uncharged it has no effect on the current, that the electron pass through the opening in it and on to the anode, if the grid is charges negatively from some outside source, it repels electrons, so that the current is reduced on intensity, with the stronger charge stopped completely. If, however, the grid is charged positively the electrons can pass and current flows. The intensity of the current is then greater than when the grid id uncharged, as positive electrons away from the filament. Most of these pass through the grid and on to the anode.
  • 8. Triode symbol. From top to bottom: plate (anode), control grid, cathode, heater (filament)
  • 9. The charge is applied to the grid from an external source are known as grid biased and, as the grid lies closer to the filament than does the plate, the grid charged has a greater influence on the flow of current than has a similar charge on the anode. The strength of the current going across the valve can be regulated, as in the diode, by altering the temperature of the filament or by altering the positive charge applied to the anode. In addition, the flow of current across the triode valve can be regulated by adjusting the biased of the grid. The triode valve has various functions in electrometrical apparatus, the principle ones being its used for the production of the interrupted direct and other muscle stimulation currents and, in conjunction with a condenser and an inductance, for the production of high frequency currents. It is not used specifically as a rectifier, but will always rectify the current that passes through it.
  • 10. TRANSISTORS – (bipolar) transistor = combination of two diodes that share middle portion, called “base” of transistor; other two sections: “emitter'' and “collector”; – usually, base is very thin and lightly doped. – two kinds of bipolar transistors: pnp and npn transistors – “pnp” means emitter is p-type, base is n-type, and collector is p-type material; – in “normal operation of pnp transistor, apply positive voltage to emitter, negative voltage to collector;
  • 11. Fig
  • 12. operation of pnp transistor:
  • 13. operation of pnp transistor: – if emitter-base junction is forward biased, “holes flow” from battery into emitter, move into base; – some holes annihilate with electrons in n-type base, but base thin and lightly doped  most holes make it through base into collector, – holes move through collector into negative terminal of battery; i.e. “collector current” flows whose size depends on how many holes have been captured by electrons in the base;
  • 14. operation of pnp transistor: • this depends on the number of n-type carriers in the base which can be controlled by the size of the current (the “base current”) that is allowed to flow from the base to the emitter; the base current is usually very small; small changes in the base current can cause a big difference in the collector current
  • 15. Transistor operation – transistor acts as amplifier of base current, since small changes in base current cause big changes in collector current. – transistor as switch: if voltage applied to base is such that emitter-base junction is reverse-biased, no current flows through transistor -- transistor is “off” – therefore, a transistor can be used as a voltage- controlled switch; computers use transistors in this way.
  • 16. What is DIATHERMY? • The use of non-ionizing electromagnetic energy from the radio-frequency spectrum as therapeutic agent
  • 17. Types of Diathermy Long wave - longest wavelength 300 – 30 m - most penetrating - no longer utilized due to high potential of causing burns and interference with radio transmissions Shortwave Microwave
  • 18. PRODUCTION OF HIGH FREQUECHY SHORT WAVES: High frequency electromagnetic waves of frequency b/w 107 or 108 and a wavelength b/w 30-3 m to generate heat in body tissues. therapeutically used and available f=27.12MHz and λ=11m commonly. It is not possible to construct any mechanical device which causes sufficient rapid movement to produce high frequency current so this type of current is obtained by discharging a condenser through an inductance of low ohmic resistance. The basic oscillator circuit consists of a condenser and an inductance and current of different frequencies are obtained by selecting suitable condensers and inductances. If a current of high frequency is required the capacity and inductance are small, while to produce a current of lower frequency a larger condenser and/or inductance are used. Basic oscillator circuit is now a days frequently replaced by a more modern oscillator such as co-axial line or pot oscillator but the principle remain same.
  • 19. In order to produce high frequency current the condenser must be made to charge and discharge repeatedly and to achieve this the oscillator is incorporated in either a spark gap or a valve circuit, the latter being commonly used in apparatus encountered in physiotherapy department. In future transistor may replace the triode valve. The high frequency current is produced in the basic oscillator which is incorporated in anode circuit of triode valve. This current produces a similar high frequency current in a second circuit, the resonator circuit by electromagnetic induction and by action of wireless waves. It is the current from this second circuit, which is used for the treatment of patients and for the production of oscillator and a resonator circuits must be in a resonance with each other. For this to occur the product of inductance and capacity must be same for both circuits.
  • 20. MICRO WAVE PRODUCTION: Microwave diathermy can be defined as Use of microwave for various therapeutic purposes. Microwave has much higher frequency and a shorter wavelength than short wave diathermy. The frequency and wavelength ranges from 300 MHz TO 300 GHz and 1cm to 1m. The commonly used frequency are 2456 MHz, 915 MHz and 433 MHz with a wavelength 12.24 cm ,32.79cm and 69cm respectively. PRODUCTION OF MICROWAVES: The microwave circuit is connected to the main AC which provides it a current of 50 Hz and a voltage of 220volts. It is not possible to produce microwaves by mechanical means and hence a special type of thermionic valve is used called magnetron. The primary function of magnetron is to produce high frequency current required for he production of microwaves. Magnetron is special type of thermionic valve characterized by centrally placed cathode and a surrounding circular metal anode.
  • 22. Coaxial cables carries this high frequency currents from the magnetron and passes it to the antenna of emitter. Emitter is also known as director or applicator consists of antenna and a reflector. Antenna is mounted in front of a metal reflector. Reflector is a metal plate which directs the microwaves in on direction only. The distance b/w the emitter and skin should be about 10-20 cms from the body. However vary according to size of emitter , the part to be treated and condition of patient.
  • 23. THERAPEUTIC EFFECTS • Increased blood flow or circulation to the area • Increased tissue temperature • Increased metabolism • Facilitate relaxation • Increased pain threshold • Decreased blood viscosity
  • 24. INDICATIONS • Soft tissue injury • Mobilization • Pain relief
  • 25. CONTRAINDICATIONS • Pacemakers • Metal implants • Impaired sensation • Pregnancy • Hemorrhage • Ischemic Tissue • Testicles and eyes • Malignant CA • Active TB • Fever • Thrombosis • X-ray exposure • Uncooperative patient • Areas of poor circulation