Xylem prepared this feature story on sizing your condensate return
unit in Volume 2, Issue 3, May 2015 and can be found Here – Xylem
Featured Story Process & Controls is pleased to share it with you.
If you require a new package feel free to contact us @
www.processandcontrols.com
How to size a condensate return unit
Facilities with their own boiler plant almost always have a closed loop system and require condensate to
be as hot as possible upon return to the boiler. Conversely, steam condensate return pumps require
subcooling to prevent cavitation or condensate flashing to vapor at the pump impellers’ suction eye. The
degree of subcooling varies with the hydraulic design and pump characteristics.
We’ve previously mentioned the effect of temperature on NPSHA vs. NPSHR of the pump. Forgetting
that effect when you pick a condensate return unit is a sure path to trouble. So, what do you need to
know when sizing a condensate return pump?
Start with the load
Boilers are rated to tell you how much steam they can put out, in terms of boiler horsepower, pounds per
hour of steam, BTUs or other ratings. It makes sense to convert the information you get from the
engineer or customer into common terms across the system. When everything is said and done, what
comes back from the boiler as condensate is .000496 gpm per 1 sq ft EDR. Rounding off, the boiler puts
out half a gallon per minute of water in the form of steam per 1000 sq ft. EDR. When the steam cools
and turns back to water, that’s the condensate you have to deal with.
Some common conversion factors:
Multiply Boiler Horsepower (BHP) by 34.5 = Lb. of steam (water per hour (lb/hr)
Multiply Boiler Horsepower (BHP) by 0.069 = Gallons of water per minute (gpm)
Multiply Boiler Horsepower (BHP) by 33,479 = BTU
Multiply Boiler Horsepower (BHP) by 139 = Square feet of equivalent direct radiation (sq ft. EDR)
Look at the evaporation rate
Knowing how much water, or water as steam, the boiler can put out is good, but don’t pick a pump size
yet. ASHRAE recommends sizing your return pump for two to three times the boiler’s evaporation rate—
so the return unit can return condensate faster than the boiler can put it out.
Think about it: All boilers have a marked water line and optimum steaming levels. If the boiler starts
pushing out steam, and your system can return condensate only as fast as the boiler puts it out, then as
the water level falls and condensate returns, you can only keep up at the lower water line not good for
the boiler. Your optimum steaming level goes out the window, and the boiler soon after. If you send extra
makeup water into the boiler, you must deal with it at some point, or you’ll flood the boiler when the boiler
stops and the condensate plus the extra water return. Even worse, adding cold city makeup water to a
steaming boiler will cause the steaming process to shut down quicker than the mouth of a toddler facing
a spoonful of peas.
What about temperature? Condensate return units are designed to collect the returns and move the
condensate along quickly and efficiently, minimizing heat loss and thus the energy required to heat it
back to steam. With prices for light sweet crude hovering around $50 to $60 a barrel, saving energy can
put a pretty penny in your pocket. So hotter is better, right?
Hold on. Remember what we said about NPSHA and NPSHR. First, when temperature goes up,
NPSHA goes down. And when the NPSHR (required) of the pump is greater than the NPSHA (available)
of the condensate, our old friend cavitation appears. The pennies you “saved” by making the returned
condensate as hot as possible will probably go to pump repair. We’ll come back to this. For now, the
next step is to figure out your discharge pressure requirement.
Calculate required discharge pressure
The required condensate unit discharge pressure includes:
• the static head lift,
• the friction loss in the piping (including pipe, fittings and valves),
• and any pressure that has to be overcome in the receiving vessel.
Manufacturers and ASHRAE generally recommend that when these values total less than 50 psi, you
add 5 psi. For totals over 50 psi, add 10 psi.
This can be a daunting calculation; you have to find out how much pipe there is, what size it is, and the
number of elbows, unions, etc. Don’t forget the isolation valves, check valves and plug cock (see
previous article on balancing). As water flows through each of these, friction slows condensate and
reduces pressure.
Refer to the charts, submittals and anything else you can grab to determine the value for each of these
(sometimes called or expressed as a ∆p), and total it all up. The result is generally expressed in feet of
head. If you’re transferring back to a vented boiler feed unit, add the 5 (or 10) psi to get your required
discharge pressure for the condensate unit.
But remember—required discharge pressure also includes any pressure in the vessel that you’re
pumping into. If that vessel is a pressurized deaerator, you have to add the maximum deaerator
pressure plus the pressure drop across the spray nozzle (on some types), because that must be
overcome to get condensate into the deaerator. If you’re pumping directly into the boiler (a rare and less
desirable option that we’ll discuss in another article), add the maximum boiler pressure.
Determine condensate return temperature
So, we now know what size pump by gpm, and what discharge pressure to size for. As we mentioned
earlier, temperature’s effect on NPSH can affect which unit you pick. That means you need to determine
condensate return temperature—not an easy task. If you’re selecting a new unit for an existing system,
you can measure the temperature of the actual condensate at your desired recovery point. But for a new
or redesigned system, you have to make the calculation before you actually turn on the system.
The return temperature matters because hotter means less NPSHA, and some pumps don’t like that.
The hotter the water, the more limited the choices. Most pumped condensate return units operate from a
vented tank. Remember, steam heating applications using thermostatic traps drain condensate around
160 to 180 degrees. At 180 degrees, a condensate pump mounted to a collection tank at the same level
as the pump will have about 15 feet of NPSHA in the water. Most pumps handle this from a vented tank
with no problem. But if the trap fails, and the temperature in the condensate tank rises to 212 degrees f.,
there is zero NPSH available. NPSH is still required, however, because it’s a function of the pump
design. Having some NPSH required vs. no NPSH available is a problem at 212 degrees: The pump
that could discharge condensate at 180 degrees will now cavitate.
Domestic® Pump Series CB
See how this changes things? Up to about 200 degrees, a standard centrifugal pump design generally
works if properly sized for the duty point and NPSHA. From 200 to 210 degrees, you need more
specialized (and somewhat more expensive) low NPSH pumps. From 210 to 212 degrees, about all you
can do is move the tank above the pump to add NPSHA, in the form of a static column of water above
the pump suction. That’s right, raising the tank provides additional NPSHA and lets you pump hotter
water. Why not raise the tank even more? Because that takes more material, which costs more money,
erasing the savings. Besides, return piping is seldom located high in the equipment space. It’s a matter
of picking the right tool for the job.
Consider condensate tank sizing
You usually want one minute net storage in a condensate tank; remember, the sooner you collect and
return condensate, the less heat it loses and the less energy required to heat back to steam. Keep in
mind that “one minute of net storage” refers to one minute of pumping capacity in storage. If you size for
one minute of return rate, the tank is undersized and forces the pump to short-cycle. That accelerates
on/off frequency as well as the wear on the pump.
Putting it all together. You know the boiler can put out half a gallon per 1000 sq ft EDR per minute.
Sizing for two times that to get the pump capacity means sizing your pump for 1 gpm per 1000 sq ft
EDR. Let’s apply that to some typical boiler sizes.
For a boiler rated 100 BHP: Use the formula above to convert boiler horsepower: BHP X 139 = sq ft
EDR. 100×139=13900. When you calculate the amount of steam put out, you get 6.9 gpm of water as
steam. Let’s round that up to 7 gpm. Sizing the pump for twice the return rate means we’ll size for 14
gpm. Now apply the 1 gpm per 1000 sq ft EDR rule of thumb. Sizing the tank for the pumping capacity
based on one minute net storage, you need a tank that is 14 gallons. If the manufacturer you use
doesn’t offer a 14-gallon tank, choose the nearest size—but beware: In this example, a tank smaller than
14 gallons will not only collect condensate quicker and pump it back to the boiler hotter, but also lack the
mass to provide the degree or two of sub cooling required to address NPSHA issues. Going smaller can
also set the pump up to short cycle. It’s better to go to the nearest larger size than your 1 minute
storage—in our example, 15 or 18 or 20 gallons.
The right equipment matters
Before the mid-1970s, most manufacturers sized for three times the boiler’s evaporation rate. Bigger
was better—and boy, what a safety factor! Sizing for three times the evaporation rate meant the pumps
were sized for 1.5 gpm per thousand square foot EDR. But when oil shortages hit the United States, and
people lined up around the block to buy a tank of gasoline, and the cost of making steam rose,
manufacturers gradually moved to sizing for two times the evaporation rate.
You can see how that makes a difference. A 15,000 sq ft EDR system puts out 7.44 gpm of condensate
as steam. Sizing for twice that, you need a 14.88 gpm pump. Sizing for one minute net storage leads
you to a 14- to 15-gallon collection vessel. In the Domestic/Hoffman pump products, you’d choose a 15
gpm unit with 14-gallon tank and, if you’re looking at a 20 psi requirement, the hp in 3500 rpm is 1/3 HP.
Compare that to sizing for three times the evaporation rate. You’re forced to go to a 22 gpm pump and
23-gallon tank, and the HP increases to 1/2 HP. You end up with a bigger, more expensive unit. What’s
more, since the evaporation rate doesn’t change, the condensate sits there longer until enough is
collected to be pumped, giving up heat (energy) that has to be added back in at the boiler. The pump
comes on less frequently, but the 1/2 HP pump costs more in electricity to run than the 1/3 HP pump.
That wraps up our tips on sizing condensate units. Watch for a future article on sizing boiler feed units—
similar to the above, but with important differences.

More Related Content

PDF
Soot Blowing Optimization- Field Experience
PDF
Selection and Design of Condensers
PDF
Shell & tube heat exchanger single fluid flow heat transfer
PPTX
DESIGN AND FABRICATION OF HELICAL TUBE IN COIL TYPE HEAT EXCHANGER
PDF
Circulating Fluidized Bed Boiler (cfb) training module
PDF
Boiler Operating Rules.pdf
DOCX
Plate Type Heat Exchanger Design
PPTX
Raw Water Intake & Pre Treatment of Raw Water in a Thermal Power Plant
Soot Blowing Optimization- Field Experience
Selection and Design of Condensers
Shell & tube heat exchanger single fluid flow heat transfer
DESIGN AND FABRICATION OF HELICAL TUBE IN COIL TYPE HEAT EXCHANGER
Circulating Fluidized Bed Boiler (cfb) training module
Boiler Operating Rules.pdf
Plate Type Heat Exchanger Design
Raw Water Intake & Pre Treatment of Raw Water in a Thermal Power Plant

What's hot (20)

PDF
Thermal fatigue failure in a FBC boiler
PPTX
Boiler Efficiency Calculation by Direct & Indirect Method
PDF
Graphite Heat Exchangers
DOCX
Heat Exchangers
PDF
Thermax B & W U BEAM TYPE
PPTX
Super Critical Technology-Fundamental Concepts about Super Critical Technolog...
PPT
Steam condensors
PPTX
refrigrants.pptx
PPTX
Shell and tube heat exchanger design comparison
PPTX
MET 214 Module 2
PDF
Large scale energy recovery ppt HRSG
PDF
Design of thermosyphon reboiler
PPTX
Thermal power plant
PPTX
CFD ANALYSIS OF DOUBLE PIPE HEAT EXCHANGER
PDF
ENERGY AUDIT METHODOLOGY FOR TURBINE CYCLE IN A POWER PLANT
PPTX
Powerplant(waterwalls)
PPTX
Oxygen treatment for super critical power plants
PPT
Baffle plate Persentation
PDF
Plate heat exchanger
PPTX
Boilers
Thermal fatigue failure in a FBC boiler
Boiler Efficiency Calculation by Direct & Indirect Method
Graphite Heat Exchangers
Heat Exchangers
Thermax B & W U BEAM TYPE
Super Critical Technology-Fundamental Concepts about Super Critical Technolog...
Steam condensors
refrigrants.pptx
Shell and tube heat exchanger design comparison
MET 214 Module 2
Large scale energy recovery ppt HRSG
Design of thermosyphon reboiler
Thermal power plant
CFD ANALYSIS OF DOUBLE PIPE HEAT EXCHANGER
ENERGY AUDIT METHODOLOGY FOR TURBINE CYCLE IN A POWER PLANT
Powerplant(waterwalls)
Oxygen treatment for super critical power plants
Baffle plate Persentation
Plate heat exchanger
Boilers
Ad

Viewers also liked (19)

PPTX
Programming for engineers in python
PPT
Poo java
PPTX
2015 bioinformatics python_introduction_wim_vancriekinge_vfinal
PPTX
2015 bioinformatics bio_cheminformatics_wim_vancriekinge
PPT
Abstract data types
PPT
Ado.net & data persistence frameworks
DOCX
X.500 More Than a Global Directory
PPTX
2016 02 23_biological_databases_part1
PDF
DIFERENCIACIÓN
PDF
المادة العلمية محاضرة 2 كيفية كتابة المسح الأدبي
PPTX
Data mining and knowledge discovery
PPT
Ρευστά σε κίνηση
PPT
Object Oriented Analysis and Design
PPTX
Memory system
PDF
GRAFICA, DOMINIO Y RANGO DE UNA FUNCIÓN
PPT
The Ldap Protocol
PPTX
memory hierarchy
PPT
Computer organization memory hierarchy
PPT
Object oriented analysis
Programming for engineers in python
Poo java
2015 bioinformatics python_introduction_wim_vancriekinge_vfinal
2015 bioinformatics bio_cheminformatics_wim_vancriekinge
Abstract data types
Ado.net & data persistence frameworks
X.500 More Than a Global Directory
2016 02 23_biological_databases_part1
DIFERENCIACIÓN
المادة العلمية محاضرة 2 كيفية كتابة المسح الأدبي
Data mining and knowledge discovery
Ρευστά σε κίνηση
Object Oriented Analysis and Design
Memory system
GRAFICA, DOMINIO Y RANGO DE UNA FUNCIÓN
The Ldap Protocol
memory hierarchy
Computer organization memory hierarchy
Object oriented analysis
Ad

Similar to How to Size a Condensate Return Unit (20)

PDF
Feb. 2016 webinar_condensate_return_piping
PDF
Steam Condensate Return Stations
PPT
Condensate Return Solutions.ppt
PDF
Boiler feed and pump sizing c-b and grundfos july 2016(1)
PDF
A Steam Heating Primer
PDF
Understanding Condensate Pumps on a Steam Distribution System
PDF
Condensate Pumps for industrial steam systems
PDF
Nlc 0280-1250-co y-un50_00
PPT
Condensate Management in Plant to save energy
PDF
Air Accessories - ELGi USA
PPTX
Module 1 heating - steam (wecompress.com)
PDF
Flash Steam and Steam Condensates in Return Lines
PDF
Technical information-2016
PPT
Energy-Saving Designs for Existing Buildings
PPT
Basic requirement for fire suppression piping - ECARO-25
PDF
Nrp 0800-1800-hp-t y-un50_00
PDF
Condensate Collection By Dk Singhal
PDF
Condensate Collection By D K Singhal
PDF
Ashrae journal -_the_fundamentals_of_expansion_tanks
Feb. 2016 webinar_condensate_return_piping
Steam Condensate Return Stations
Condensate Return Solutions.ppt
Boiler feed and pump sizing c-b and grundfos july 2016(1)
A Steam Heating Primer
Understanding Condensate Pumps on a Steam Distribution System
Condensate Pumps for industrial steam systems
Nlc 0280-1250-co y-un50_00
Condensate Management in Plant to save energy
Air Accessories - ELGi USA
Module 1 heating - steam (wecompress.com)
Flash Steam and Steam Condensates in Return Lines
Technical information-2016
Energy-Saving Designs for Existing Buildings
Basic requirement for fire suppression piping - ECARO-25
Nrp 0800-1800-hp-t y-un50_00
Condensate Collection By Dk Singhal
Condensate Collection By D K Singhal
Ashrae journal -_the_fundamentals_of_expansion_tanks

How to Size a Condensate Return Unit

  • 1. Xylem prepared this feature story on sizing your condensate return unit in Volume 2, Issue 3, May 2015 and can be found Here – Xylem Featured Story Process & Controls is pleased to share it with you. If you require a new package feel free to contact us @ www.processandcontrols.com How to size a condensate return unit
  • 2. Facilities with their own boiler plant almost always have a closed loop system and require condensate to be as hot as possible upon return to the boiler. Conversely, steam condensate return pumps require subcooling to prevent cavitation or condensate flashing to vapor at the pump impellers’ suction eye. The degree of subcooling varies with the hydraulic design and pump characteristics. We’ve previously mentioned the effect of temperature on NPSHA vs. NPSHR of the pump. Forgetting that effect when you pick a condensate return unit is a sure path to trouble. So, what do you need to know when sizing a condensate return pump? Start with the load Boilers are rated to tell you how much steam they can put out, in terms of boiler horsepower, pounds per hour of steam, BTUs or other ratings. It makes sense to convert the information you get from the engineer or customer into common terms across the system. When everything is said and done, what comes back from the boiler as condensate is .000496 gpm per 1 sq ft EDR. Rounding off, the boiler puts out half a gallon per minute of water in the form of steam per 1000 sq ft. EDR. When the steam cools and turns back to water, that’s the condensate you have to deal with. Some common conversion factors: Multiply Boiler Horsepower (BHP) by 34.5 = Lb. of steam (water per hour (lb/hr) Multiply Boiler Horsepower (BHP) by 0.069 = Gallons of water per minute (gpm) Multiply Boiler Horsepower (BHP) by 33,479 = BTU Multiply Boiler Horsepower (BHP) by 139 = Square feet of equivalent direct radiation (sq ft. EDR) Look at the evaporation rate Knowing how much water, or water as steam, the boiler can put out is good, but don’t pick a pump size yet. ASHRAE recommends sizing your return pump for two to three times the boiler’s evaporation rate— so the return unit can return condensate faster than the boiler can put it out. Think about it: All boilers have a marked water line and optimum steaming levels. If the boiler starts pushing out steam, and your system can return condensate only as fast as the boiler puts it out, then as the water level falls and condensate returns, you can only keep up at the lower water line not good for the boiler. Your optimum steaming level goes out the window, and the boiler soon after. If you send extra makeup water into the boiler, you must deal with it at some point, or you’ll flood the boiler when the boiler stops and the condensate plus the extra water return. Even worse, adding cold city makeup water to a steaming boiler will cause the steaming process to shut down quicker than the mouth of a toddler facing a spoonful of peas. What about temperature? Condensate return units are designed to collect the returns and move the condensate along quickly and efficiently, minimizing heat loss and thus the energy required to heat it back to steam. With prices for light sweet crude hovering around $50 to $60 a barrel, saving energy can put a pretty penny in your pocket. So hotter is better, right? Hold on. Remember what we said about NPSHA and NPSHR. First, when temperature goes up, NPSHA goes down. And when the NPSHR (required) of the pump is greater than the NPSHA (available) of the condensate, our old friend cavitation appears. The pennies you “saved” by making the returned condensate as hot as possible will probably go to pump repair. We’ll come back to this. For now, the next step is to figure out your discharge pressure requirement.
  • 3. Calculate required discharge pressure The required condensate unit discharge pressure includes: • the static head lift, • the friction loss in the piping (including pipe, fittings and valves), • and any pressure that has to be overcome in the receiving vessel. Manufacturers and ASHRAE generally recommend that when these values total less than 50 psi, you add 5 psi. For totals over 50 psi, add 10 psi. This can be a daunting calculation; you have to find out how much pipe there is, what size it is, and the number of elbows, unions, etc. Don’t forget the isolation valves, check valves and plug cock (see previous article on balancing). As water flows through each of these, friction slows condensate and reduces pressure. Refer to the charts, submittals and anything else you can grab to determine the value for each of these (sometimes called or expressed as a ∆p), and total it all up. The result is generally expressed in feet of head. If you’re transferring back to a vented boiler feed unit, add the 5 (or 10) psi to get your required discharge pressure for the condensate unit. But remember—required discharge pressure also includes any pressure in the vessel that you’re pumping into. If that vessel is a pressurized deaerator, you have to add the maximum deaerator pressure plus the pressure drop across the spray nozzle (on some types), because that must be overcome to get condensate into the deaerator. If you’re pumping directly into the boiler (a rare and less desirable option that we’ll discuss in another article), add the maximum boiler pressure. Determine condensate return temperature So, we now know what size pump by gpm, and what discharge pressure to size for. As we mentioned earlier, temperature’s effect on NPSH can affect which unit you pick. That means you need to determine condensate return temperature—not an easy task. If you’re selecting a new unit for an existing system, you can measure the temperature of the actual condensate at your desired recovery point. But for a new or redesigned system, you have to make the calculation before you actually turn on the system. The return temperature matters because hotter means less NPSHA, and some pumps don’t like that. The hotter the water, the more limited the choices. Most pumped condensate return units operate from a vented tank. Remember, steam heating applications using thermostatic traps drain condensate around 160 to 180 degrees. At 180 degrees, a condensate pump mounted to a collection tank at the same level as the pump will have about 15 feet of NPSHA in the water. Most pumps handle this from a vented tank with no problem. But if the trap fails, and the temperature in the condensate tank rises to 212 degrees f., there is zero NPSH available. NPSH is still required, however, because it’s a function of the pump design. Having some NPSH required vs. no NPSH available is a problem at 212 degrees: The pump that could discharge condensate at 180 degrees will now cavitate.
  • 4. Domestic® Pump Series CB See how this changes things? Up to about 200 degrees, a standard centrifugal pump design generally works if properly sized for the duty point and NPSHA. From 200 to 210 degrees, you need more specialized (and somewhat more expensive) low NPSH pumps. From 210 to 212 degrees, about all you can do is move the tank above the pump to add NPSHA, in the form of a static column of water above the pump suction. That’s right, raising the tank provides additional NPSHA and lets you pump hotter water. Why not raise the tank even more? Because that takes more material, which costs more money, erasing the savings. Besides, return piping is seldom located high in the equipment space. It’s a matter of picking the right tool for the job. Consider condensate tank sizing You usually want one minute net storage in a condensate tank; remember, the sooner you collect and return condensate, the less heat it loses and the less energy required to heat back to steam. Keep in mind that “one minute of net storage” refers to one minute of pumping capacity in storage. If you size for one minute of return rate, the tank is undersized and forces the pump to short-cycle. That accelerates on/off frequency as well as the wear on the pump. Putting it all together. You know the boiler can put out half a gallon per 1000 sq ft EDR per minute. Sizing for two times that to get the pump capacity means sizing your pump for 1 gpm per 1000 sq ft EDR. Let’s apply that to some typical boiler sizes. For a boiler rated 100 BHP: Use the formula above to convert boiler horsepower: BHP X 139 = sq ft EDR. 100×139=13900. When you calculate the amount of steam put out, you get 6.9 gpm of water as steam. Let’s round that up to 7 gpm. Sizing the pump for twice the return rate means we’ll size for 14 gpm. Now apply the 1 gpm per 1000 sq ft EDR rule of thumb. Sizing the tank for the pumping capacity based on one minute net storage, you need a tank that is 14 gallons. If the manufacturer you use doesn’t offer a 14-gallon tank, choose the nearest size—but beware: In this example, a tank smaller than 14 gallons will not only collect condensate quicker and pump it back to the boiler hotter, but also lack the mass to provide the degree or two of sub cooling required to address NPSHA issues. Going smaller can also set the pump up to short cycle. It’s better to go to the nearest larger size than your 1 minute storage—in our example, 15 or 18 or 20 gallons.
  • 5. The right equipment matters Before the mid-1970s, most manufacturers sized for three times the boiler’s evaporation rate. Bigger was better—and boy, what a safety factor! Sizing for three times the evaporation rate meant the pumps were sized for 1.5 gpm per thousand square foot EDR. But when oil shortages hit the United States, and people lined up around the block to buy a tank of gasoline, and the cost of making steam rose, manufacturers gradually moved to sizing for two times the evaporation rate. You can see how that makes a difference. A 15,000 sq ft EDR system puts out 7.44 gpm of condensate as steam. Sizing for twice that, you need a 14.88 gpm pump. Sizing for one minute net storage leads you to a 14- to 15-gallon collection vessel. In the Domestic/Hoffman pump products, you’d choose a 15 gpm unit with 14-gallon tank and, if you’re looking at a 20 psi requirement, the hp in 3500 rpm is 1/3 HP. Compare that to sizing for three times the evaporation rate. You’re forced to go to a 22 gpm pump and 23-gallon tank, and the HP increases to 1/2 HP. You end up with a bigger, more expensive unit. What’s more, since the evaporation rate doesn’t change, the condensate sits there longer until enough is collected to be pumped, giving up heat (energy) that has to be added back in at the boiler. The pump comes on less frequently, but the 1/2 HP pump costs more in electricity to run than the 1/3 HP pump. That wraps up our tips on sizing condensate units. Watch for a future article on sizing boiler feed units— similar to the above, but with important differences.