SlideShare a Scribd company logo
Series 70 eRDP
Web Enabled Remote Distribution Panel
The Foundation Layer
Product Brochure
eRDP Is Inspired by NFPA-70E
The Series 70 eRDP is a Power Distribution Unit for critical industries. It features an NFPA 70E friendly design, open layout,
and the IP-20 rated Finger-Safe SafePanel, to help protect operators and ensure safe operation. With an emphasis on
reliability, safety, connectivity, and power quality monitoring, the Series 70 eRDP provides high-reliability power.
The Series 70 eRDP is designed to be flexible, ideal for growing or constantly changing environments.
The LayerZero eRDP Remote Distribution Panel
Maximizes Power Reliability
2
Web-Enabled Distribution PanelSeries 70 eRDP
2 © Copyright 2016 LayerZero Power Systems, Inc.
LayerZero’s eRDP Product Features
;; Silver Plated Input Terminals: Silver Has Excellent Conductivity To Provide Superior Electrical Performance and Reliability
;; Machined Hardware: Machined Cap Screws and Engineered Disc Springs Maintain Constant Torque Throughout Product Life
;; Convection Cooling: Natural Convection-Cooled Heat Dissipation System is Maintenance-Free
;; Serialized Critical Board Tracking: Critical Boards Are Serialized And Cataloged in an Active Database For Traceability
;; Selective Trip Coordination: Main Breaker Will Not Trip In The Event of a Downstream Fault.
Reliability
Safety
;; InSight™ IR Portholes: Bolted Connections Can Be IR Scanned With the Dead-Front Doors Closed
;; Sectionalized Components: Separations Between Each Section To Maintain Maximum Operator Safety
;; Polycarbonate Windows: Allows Circuit Breaker Positions Viewed With The Dead-Front Door Closed
;; Dead Front Hinged Doors: Barrier To Provide A Safe Working Area With No Exposed Live Parts
;; Guided Wireways: Helps Keep Wires Organized
Connectivity
;; Ethernet Connectivity: Secure VPN Router Connects To Network For Advanced Remote Monitoring Capabilities
;; Modbus/TCP: Open Connectivity to Existing Monitoring Systems Without Proprietary Limitations
;; NTP Time Clock Synchronization: Facilitates Timeline-Based Logging For Post-Event Reconstruction
;; SNMP Connectivity: Permits Remote Management Via Simple Network Management Protocol
;; Bluetooth Connectivity: Wirelessly Set Up Panels At The Point-Of-Impact
;; Real-Time Waveform Capture: Automatically Captures A Picture Of The Power Six-Cycles Before and After Every Event
;; Optional Local Touch-Screen Interface: Password-Protected Color Touch-Screen GUI For Local ePODs Setup/Operation
;; Black-Box Forensics: eRDP Captures and Records Events To Provide Vital Information In Root-Cause Analysis
Web-Enabled Distribution PanelSeries 70 eRDP
3 © Copyright 2016 LayerZero Power Systems, Inc.
Main Circuit Breaker Section:
Louvered Vents:
Convection-Cooled Exhaust
Polycarbonate
Window:
View CB Positions
with Door Closed
Monitoring/Distribution Section:
LCD Membrane Panel
Color-Touch Screen Interface
(Optional)
eRDP Supports Top or Bottom Exit.
In this ultra-high-density depiction, eRDPs are feeding
ePanel-HD Power Panels.
Web-Enabled Distribution PanelSeries 70 eRDP
4 © Copyright 2016 LayerZero Power Systems, Inc.
Equipment Layout
5
1. Hinged Dead Front Doors
2. Silver Plated Terminals
3. Zen Monitoring Local Display
4. Polycarbonate Window
5. InSight™ IR Portholes
6. Convection Cooled Exhaust
7. Main Circuit Breaker
8. Branch Circuit Breakers
9. CTs For Power Quality Monitoring
10. Zen DPQM Controls
11. Guided Wireways for Organized Cabling
1
2
3
4
5
6
7
8
9
10
11
4. Alarm Indicator
5. PBM Status Indicator
6. Logged In User
7. Navigation Menu
12
13 14
15
Web-Enabled Distribution PanelSeries 70 eRDP
5 © Copyright 2016 LayerZero Power Systems, Inc.
Equipment Construction Detail
Serialized Circuit Boards
We serialize and track all critical circuit boards and memory cards
through our eBOSS portal, which allows customers to reference
which components their machines are made from, who tested the
components, as well as the ability to view notes generated from
testing.
Serialized components offer the ability to drill-down on prospective
component failure utilizing predictive modeling techniques, so if part
fails, the instance can be cross-referenced with similar parts. This
preventative maintenance helps ensure maximum uptime.
Silver Plated Terminals
LayerZero utilizes silver plating on all input terminals to be able to
provide the highest performance. Silver has high conductivity and low
resistance - which makes for a great contact.
Web-Enabled Distribution PanelSeries 70 eRDP
6 © Copyright 2016 LayerZero Power Systems, Inc.
Reliability Features
77
Scan Bolted Connections with Dead-Front Doors Closed
Strategically positioned IR-scan portholes to enable safe thermal
scanning of all bolted connections with the deadfront closed, without
exposing the operator to power circuit voltage.
The IR window swivels upward and unlocks with key-hole access
to reveal a mesh, allowing the operator to point-and-shoot
thermal cameras to obtain accurate readings. LayerZero provides
documentation for proper thermal scanning procedures.
View CB Positions With Dead-Front Doors Closed
The Series 70: eRDP is equipped with polycarbonate windows located
on the outer door of the subfeed circuit breaker section.
Circuit breaker positions can be viewed with the dead-front door
closed.
Web-Enabled Distribution PanelSeries 70 eRDP
7 © Copyright 2016 LayerZero Power Systems, Inc.
Safety Features/Ease of Maintenance
88
Guided Wireways
Help keep cables and wiring organized with our guided wireways and
cable clips.
Sectionalization Maximizes Operator Safety
Operators are well-protected from exposed connections. Normal
operator sections (breakers/switches) are physically separated
from the power electronics and control electronics sections, so that
maintenance on a section can be safely performed. If maintenance is
required on a particular section, power can be bypassed to another
section to allow for safe repairs to be made.
After installation, there is no need to open the eRDP left cabinet.
Web-Enabled Distribution PanelSeries 70 eRDP
8 © Copyright 2016 LayerZero Power Systems, Inc.
Safety Features/Ease of Maintenance
The Breaker Is Inserted Into The SafePanel The Handle Is Unlocked
Screws Help Secure The Breaker For Maximum Safety, The SafePanel Has
Recessed Bus Work and Finger Safe Lattice.
eRDP 1200 A Circuit Breaker Installation Process
The LayerZero SafePanel™
The Series 70 eRDP features an IP-20, finger-safe panel board,
meaning that the opening will not allow ingress of ½” (12.5mm)
diameter probe, for maximum operator safety.
An arc can form as two live conductors are separated – such as
the removal of a circuit breaker from a panel board. The SafePanel
design ensures that a potential arc would be contained in the
connection well so that even if a branch breaker were to be
removed, the arc would be contained in the connection well.
Insulated with the components deeply isolated, removal of the
breaker is safe and easy.
Web-Enabled Distribution PanelSeries 70 eRDP
9 © Copyright 2016 LayerZero Power Systems, Inc.
Safety Features
Modbus/TCP http:// through a
standard web browser
Simple Network
Management Protocol
(SNMP)
Standard
Ethernet
Dry Contacts
• Meters
• Alarms
• Alarms • Alarms• Panel
Setup
• Meters
• Alarms
• Waveforms
• History/Event Log
• Diagnostics
Series 70
eRDP
Bluetooth Keeps Circuit Level Information Up-To-Date
Coordinate efforts to keep panel board naming conventions accurate
and up-to-date with Bluetooth connectivity. In critical facilities,
Facilities typically install the physical circuit breakers, while IT workers
manage naming of panel designations.
With Bluetooth connectivity, the naming, size, and assignment of
circuit breakers can be taken care of at the point-of-impact, bringing
together the efforts of facilities and IT for more accurate deployment.
Web-Enabled Distribution PanelSeries 70 eRDP
10 © Copyright 2016 LayerZero Power Systems, Inc.
Connectivity Options
The Series 70 eRPP is equipped with Zen DPQM
(Distribution Power Quality Monitoring), an all
encompassing monitoring system with local and
remote communications options.
From basic monitoring & alarm reporting, to advanced
power quality monitoring functionality, Zen DPQM
provides a wide-range of options to help you be aware,
be vigilant, be proactive in your quest to create a safe,
stable and reliable operation.
Zen DPQM Provides Answers
Zen DPQM provides timestamped pictures of waveforms before and after events, providing information that
enables facilities to go back in time to methodically identify and correct the root causes of events. Zen actively
captures power quality information at the STS, PDU, and RPP - permitting thorough post-event analysis.
6 Electrical Cycles 6 Electrical Cycles
Waveform Capture of Power Quality Issue
Trigger Event
Phase A
Phase B
Phase C
Web-Enabled Distribution PanelSeries 70 eRDP
11 © Copyright 2016 LayerZero Power Systems, Inc.
Power Quality Monitoring
PBM
MCB
(Optional - Not Displayed)
Inputs
Sub-Feeds
PBM
Sub-Feeds
A
V
PQ
Current Metering Point
Voltage Metering Point
Power Quality Metering Point
BM Branch Current Monitoring
Web-Enabled Distribution PanelSeries 70 eRDP
12 © Copyright 2016 LayerZero Power Systems, Inc.
Power Quality Monitoring
Zen DPQM Parameters Mains
Subfeeds or Branch
Circuits
Voltage Monitor
Volts (L-L) Phase A/B/C (volts RMS)
Volts (L-N) Phase A/B/C (volts RMS)
Phase Rotation
Current Monitor
CT Reversed Phase A/B/C/N
Current Phase A/B/C/N (amperes RMS)
Power Monitor
Frequency (hertz)
Real Power (kilowatts)
Apparent Power (kilovolt-amperes)
Reactive Power (kilovolt-amperes reactive)
Power Factor
Energy (kilowatt-hours)
Block Demand (kilowatts)
Block Demand Peak (kilowatts)
Rolling Demand (kilowatts)
Rolling Demand Peak (kilowatts)
Power Quality
Percent VTHD (percent)
Waveform Capture
Alarms
Phase - Under Voltage A/B/C (Alarm)
Phase - Over Voltage A/B/C (Alarm)
Phase - Low Voltage A/B/C (Warning)
Phase - High Voltage A/B/C (Warning)
Phase - Over Current A/B/C (Alarm)
Phase - High Current A/B/C (Warning)
Under Frequency (Alarm)
Over Frequency (Alarm)
High VTHD (Warning)
Over VTHD (Alarm)
Phase Rotation (Alarm)
All product specifications are subject to change without notice.
Web-Enabled Distribution PanelSeries 70 eRDP
13 © Copyright 2016 LayerZero Power Systems, Inc.
Technical Specifications
eRDP Models with System Withstand Ratings
120/208V, 3-Phase, 4-Wire + Ground 100 kA
220/380V, 3-Phase, 4-Wire + Ground
65 kA
230/400V, 3-Phase, 4-Wire + Ground
240/415V, 3-Phase, 4-Wire + Ground
277/480V, 3-Phase, 4-Wire + Ground
480V, 3-Phase, 3-Wire + Ground
575V, 3-Phase, 3-Wire + Ground
42 kA
600V, 3-Phase, 3-Wire + Ground
Mechanical Characteristics
Dimensions 47”W x 89”H x 18”D (1194 mm x 2260 mm x 457 mm)
Weight 912 lbs (414 kg)
Enclosure Mounting Wall-Mounted
Frame Construction Welded Frame
Electrical Connections Flexible Laminated Bus, Silver-Plated Solid Busbar
Color Textured Powder Coat White (RAL 7035), Blue (RAL 5017), Black, Custom
Seismic Floor Anchors Optional
Seismic Floor Stand Optional
Sectionalization Engineered Composite Insulation, Dead Front Doors
Circuit Breaker Identification Labels Viewable Through Polycarbonate Window
Electrical Characteristics
Input Voltage 120/208V, 3-Phase, 4-Wire + Ground; 220/380V, 3-Phase, 4-Wire + Ground; 230/400V, 3-Phase, 4-Wire + Ground;
240/415V, 3-Phase, 4-Wire + Ground; 277/480V, 3-Phase, 4-Wire + Ground; 480V, 3-Phase, 3-Wire + Ground; 575V,
3-Phase, 3-Wire + Ground; 600V, 3-Phase, 3-Wire + Ground
Withstand 100 kA
Configuration Parallel (P), Shared Parallel (SP), Dedicated (D), Feed Through (FT)
Frequency 50 Hz, 60 Hz
Poles 3-pole, 4-pole
Neutral Rating 100%, 200%
Circuit Breaker Type Electronic Trip, Molded Case Switch
Distribution SafePanel™ Distribution
Power Quality Monitoring
Power Quality Monitoring Technology Zen DPQM™ (Distribution Power Quality Monitoring)
Waveform Capture Local Display, Remote Display via Web Browser
All product specifications are subject to change without notice.
Web-Enabled Distribution PanelSeries 70 eRDP
14 © Copyright 2016 LayerZero Power Systems, Inc.
Technical Specifications
Operational Characteristics
Cooling Convection Cooling
Cable Access Top/Bottom
Service Access Front Only Access
IR Scan Port Type InSight™ IR Portholes
Display Type 3.2” LCD with Membrane, 10.5” Color Touch Screen GUI (Optional)
Connectivity
Meters Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary)
Alarms Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary)
Summary Alarm Dry Contacts
Waveforms Local Display, Ethernet, http via Web Browser (Non-Proprietary)
History/Event Log Local Display, Ethernet, http via Web Browser (Non-Proprietary)
Diagnostics Local Display, Ethernet, http via Web Browser (Non-Proprietary)
Time Synchronization Network Time Protocol (NTP)
Standards Conformance
UL ETL and cETL listed to UL 60950
Number of Output Circuit Breakers
Number of Available SafePanel™ Slots 36
CB Rating Number of Slots Required
100 AF 2
250 AF 3
400 AF 3
400 AF 100% 6
800 AF 6
All product specifications are subject to change without notice.
36 Total
Available Slots
1 Slot
2 Slots
3 Slots
6 Slots
Universal Dead FrontSafePanel™ Panel Board
Interchangeable
Plates Fit All CB Sizes
Blank Plates
Web-Enabled Distribution PanelSeries 70 eRDP
15 © Copyright 2016 LayerZero Power Systems, Inc.
Technical Specifications
LayerZero Power Systems, Inc.
1500 Danner Drive
Aurora, OH 44202 U.S.A.
© 2016 LayerZero Power Systems, Inc.
LayerZero Power Systems, LayerZero.com and the LayerZero logo are registered trademark of LayerZero.
All product specifications are subject to change without notice.
Learn more at www.LayerZero.com
Rev. 7/16 #16

More Related Content

PDF
LayerZero Series 70: eRDP-FS Remote Distribution Panel with Front/Side Access
PDF
LayerZero Series 70: eRPP-SL2 Slim Remote Power Panel
PDF
LayerZero Series 70: eRPP Remote Power Panel
PDF
LayerZero Series 70: ePanel-1 Wall-Mounted Power Panel
PDF
LayerZero Series 70: ePanel-2 Wall-Mounted Power Panel
PDF
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
PDF
LayerZero Series 70: ePanel-HD2 High Density Power Panel
PDF
LayerZero Series 70 ePODs: Type-X Power Distribution Unit with Transformer an...
LayerZero Series 70: eRDP-FS Remote Distribution Panel with Front/Side Access
LayerZero Series 70: eRPP-SL2 Slim Remote Power Panel
LayerZero Series 70: eRPP Remote Power Panel
LayerZero Series 70: ePanel-1 Wall-Mounted Power Panel
LayerZero Series 70: ePanel-2 Wall-Mounted Power Panel
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
LayerZero Series 70: ePanel-HD2 High Density Power Panel
LayerZero Series 70 ePODs: Type-X Power Distribution Unit with Transformer an...

What's hot (19)

PDF
LayerZero Power Systems Corporate Brochure
PDF
Rfs7000 series switch installation guide
PDF
High Speed Data Connectivity: More Than Hardware - VE2013
PDF
5808spec
PDF
Motorola solutions ap622 access point installation guide (part no. 72 e 15780...
PDF
LayerZero Series 70 ePODs: Dual Type-P
PDF
Motorola rfs6000 series rf switch installation guide
PDF
718001 000 en
PPTX
Industry’s performance leading ultra low-power dsp solution
PDF
compliant charging controller for electric vehicle
PDF
QuickSilver Controls QCI-DS023 QCI-D2-IGK
PDF
Catálogo Paradox G2K
PDF
Webinar: Wearables - Apresentando um diagrama de blocos e componentes chaves
PPTX
SPIsolator Dedicated Digital Isolator for SPI Communications
PDF
00 control panel xv specifications sheet
PDF
Data sheet en_us_1872223499
PDF
85 0135 b-installation manual_web
PDF
Cfs0065 ccat-r1-4 part7
LayerZero Power Systems Corporate Brochure
Rfs7000 series switch installation guide
High Speed Data Connectivity: More Than Hardware - VE2013
5808spec
Motorola solutions ap622 access point installation guide (part no. 72 e 15780...
LayerZero Series 70 ePODs: Dual Type-P
Motorola rfs6000 series rf switch installation guide
718001 000 en
Industry’s performance leading ultra low-power dsp solution
compliant charging controller for electric vehicle
QuickSilver Controls QCI-DS023 QCI-D2-IGK
Catálogo Paradox G2K
Webinar: Wearables - Apresentando um diagrama de blocos e componentes chaves
SPIsolator Dedicated Digital Isolator for SPI Communications
00 control panel xv specifications sheet
Data sheet en_us_1872223499
85 0135 b-installation manual_web
Cfs0065 ccat-r1-4 part7
Ad

Viewers also liked (13)

PDF
certificate
PPTX
Alexis nicolas saucedo_ramirez_unidad ii
PDF
Rebekah Spicuglia_Resume 2016
PDF
Eliminatoria classificacao secundário
PPTX
Rural Development Minister
PDF
Nolan G Manion Resume
PPTX
Histriadasvogais 090522100120-phpapp01
PDF
Introduction to Mechanical Measurement
PDF
Effective Court Oversight to Support and Enforce Normalcy and Youth Engagement
PPTX
Relacion entre los sistemas naturales y sociales
PDF
Patient satisfaction surveys should focus on meaningful information
PDF
A COMPARATIVE STUDY ALGORITHM FOR NOISY IMAGE RESTORATION IN THE FIELD OF MED...
PPT
The interconnection between Islam and Tswana culture - Edwin Salim Saidoo
certificate
Alexis nicolas saucedo_ramirez_unidad ii
Rebekah Spicuglia_Resume 2016
Eliminatoria classificacao secundário
Rural Development Minister
Nolan G Manion Resume
Histriadasvogais 090522100120-phpapp01
Introduction to Mechanical Measurement
Effective Court Oversight to Support and Enforce Normalcy and Youth Engagement
Relacion entre los sistemas naturales y sociales
Patient satisfaction surveys should focus on meaningful information
A COMPARATIVE STUDY ALGORITHM FOR NOISY IMAGE RESTORATION IN THE FIELD OF MED...
The interconnection between Islam and Tswana culture - Edwin Salim Saidoo
Ad

Similar to LayerZero Series 70: eRDP Remote Distribution Panel (20)

PDF
LayerZero Series 70 ePODs: Type-P Power Distribution Unit with Transformer an...
PDF
Compromising Industrial Facilities From 40 Miles Away
PDF
LayerZero Series 70 ePODs: Type-N Static Transfer Switch with Distribution
PDF
LayerZero Series 70 ePODs: Type-S (Power Distribution Unit)
PDF
7SR105 Motor Protection Relay
PDF
PDF
Sa*ple
PDF
PDF
5G transformation with Open Source (on ONF)
PDF
NGR Monitor
PDF
alm.pdf
PDF
alm.pdf
PPTX
PARAMETER SENSING REMOTE OPERATED VIDEO ENHANCED RECEIVER
PDF
AD5235 DataSheet - (ic-component.com)
PDF
7SC80 Feeder Automation Controller
PDF
7SR158 Argus Relay
PDF
SDS_SSL_MPM_UN_A4
PDF
7SR220 Overcurrent Relay
PPTX
72 pig farm solution.pptx
PDF
Ls catalog thiet bi tu dong gipam 2200-e
LayerZero Series 70 ePODs: Type-P Power Distribution Unit with Transformer an...
Compromising Industrial Facilities From 40 Miles Away
LayerZero Series 70 ePODs: Type-N Static Transfer Switch with Distribution
LayerZero Series 70 ePODs: Type-S (Power Distribution Unit)
7SR105 Motor Protection Relay
Sa*ple
5G transformation with Open Source (on ONF)
NGR Monitor
alm.pdf
alm.pdf
PARAMETER SENSING REMOTE OPERATED VIDEO ENHANCED RECEIVER
AD5235 DataSheet - (ic-component.com)
7SC80 Feeder Automation Controller
7SR158 Argus Relay
SDS_SSL_MPM_UN_A4
7SR220 Overcurrent Relay
72 pig farm solution.pptx
Ls catalog thiet bi tu dong gipam 2200-e

Recently uploaded (20)

PDF
Review of recent advances in non-invasive hemoglobin estimation
PDF
Building Integrated photovoltaic BIPV_UPV.pdf
PDF
Electronic commerce courselecture one. Pdf
PPTX
MYSQL Presentation for SQL database connectivity
PDF
Agricultural_Statistics_at_a_Glance_2022_0.pdf
PDF
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
PPTX
Big Data Technologies - Introduction.pptx
PDF
Advanced methodologies resolving dimensionality complications for autism neur...
PPT
Teaching material agriculture food technology
PDF
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
PPTX
VMware vSphere Foundation How to Sell Presentation-Ver1.4-2-14-2024.pptx
PDF
Reach Out and Touch Someone: Haptics and Empathic Computing
PDF
How UI/UX Design Impacts User Retention in Mobile Apps.pdf
PDF
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
PDF
cuic standard and advanced reporting.pdf
PDF
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
PDF
Dropbox Q2 2025 Financial Results & Investor Presentation
PDF
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
PPTX
Effective Security Operations Center (SOC) A Modern, Strategic, and Threat-In...
PDF
NewMind AI Weekly Chronicles - August'25 Week I
Review of recent advances in non-invasive hemoglobin estimation
Building Integrated photovoltaic BIPV_UPV.pdf
Electronic commerce courselecture one. Pdf
MYSQL Presentation for SQL database connectivity
Agricultural_Statistics_at_a_Glance_2022_0.pdf
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
Big Data Technologies - Introduction.pptx
Advanced methodologies resolving dimensionality complications for autism neur...
Teaching material agriculture food technology
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
VMware vSphere Foundation How to Sell Presentation-Ver1.4-2-14-2024.pptx
Reach Out and Touch Someone: Haptics and Empathic Computing
How UI/UX Design Impacts User Retention in Mobile Apps.pdf
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
cuic standard and advanced reporting.pdf
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
Dropbox Q2 2025 Financial Results & Investor Presentation
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
Effective Security Operations Center (SOC) A Modern, Strategic, and Threat-In...
NewMind AI Weekly Chronicles - August'25 Week I

LayerZero Series 70: eRDP Remote Distribution Panel

  • 1. Series 70 eRDP Web Enabled Remote Distribution Panel The Foundation Layer Product Brochure
  • 2. eRDP Is Inspired by NFPA-70E The Series 70 eRDP is a Power Distribution Unit for critical industries. It features an NFPA 70E friendly design, open layout, and the IP-20 rated Finger-Safe SafePanel, to help protect operators and ensure safe operation. With an emphasis on reliability, safety, connectivity, and power quality monitoring, the Series 70 eRDP provides high-reliability power. The Series 70 eRDP is designed to be flexible, ideal for growing or constantly changing environments. The LayerZero eRDP Remote Distribution Panel Maximizes Power Reliability 2 Web-Enabled Distribution PanelSeries 70 eRDP 2 © Copyright 2016 LayerZero Power Systems, Inc.
  • 3. LayerZero’s eRDP Product Features ;; Silver Plated Input Terminals: Silver Has Excellent Conductivity To Provide Superior Electrical Performance and Reliability ;; Machined Hardware: Machined Cap Screws and Engineered Disc Springs Maintain Constant Torque Throughout Product Life ;; Convection Cooling: Natural Convection-Cooled Heat Dissipation System is Maintenance-Free ;; Serialized Critical Board Tracking: Critical Boards Are Serialized And Cataloged in an Active Database For Traceability ;; Selective Trip Coordination: Main Breaker Will Not Trip In The Event of a Downstream Fault. Reliability Safety ;; InSight™ IR Portholes: Bolted Connections Can Be IR Scanned With the Dead-Front Doors Closed ;; Sectionalized Components: Separations Between Each Section To Maintain Maximum Operator Safety ;; Polycarbonate Windows: Allows Circuit Breaker Positions Viewed With The Dead-Front Door Closed ;; Dead Front Hinged Doors: Barrier To Provide A Safe Working Area With No Exposed Live Parts ;; Guided Wireways: Helps Keep Wires Organized Connectivity ;; Ethernet Connectivity: Secure VPN Router Connects To Network For Advanced Remote Monitoring Capabilities ;; Modbus/TCP: Open Connectivity to Existing Monitoring Systems Without Proprietary Limitations ;; NTP Time Clock Synchronization: Facilitates Timeline-Based Logging For Post-Event Reconstruction ;; SNMP Connectivity: Permits Remote Management Via Simple Network Management Protocol ;; Bluetooth Connectivity: Wirelessly Set Up Panels At The Point-Of-Impact ;; Real-Time Waveform Capture: Automatically Captures A Picture Of The Power Six-Cycles Before and After Every Event ;; Optional Local Touch-Screen Interface: Password-Protected Color Touch-Screen GUI For Local ePODs Setup/Operation ;; Black-Box Forensics: eRDP Captures and Records Events To Provide Vital Information In Root-Cause Analysis Web-Enabled Distribution PanelSeries 70 eRDP 3 © Copyright 2016 LayerZero Power Systems, Inc.
  • 4. Main Circuit Breaker Section: Louvered Vents: Convection-Cooled Exhaust Polycarbonate Window: View CB Positions with Door Closed Monitoring/Distribution Section: LCD Membrane Panel Color-Touch Screen Interface (Optional) eRDP Supports Top or Bottom Exit. In this ultra-high-density depiction, eRDPs are feeding ePanel-HD Power Panels. Web-Enabled Distribution PanelSeries 70 eRDP 4 © Copyright 2016 LayerZero Power Systems, Inc. Equipment Layout
  • 5. 5 1. Hinged Dead Front Doors 2. Silver Plated Terminals 3. Zen Monitoring Local Display 4. Polycarbonate Window 5. InSight™ IR Portholes 6. Convection Cooled Exhaust 7. Main Circuit Breaker 8. Branch Circuit Breakers 9. CTs For Power Quality Monitoring 10. Zen DPQM Controls 11. Guided Wireways for Organized Cabling 1 2 3 4 5 6 7 8 9 10 11 4. Alarm Indicator 5. PBM Status Indicator 6. Logged In User 7. Navigation Menu 12 13 14 15 Web-Enabled Distribution PanelSeries 70 eRDP 5 © Copyright 2016 LayerZero Power Systems, Inc. Equipment Construction Detail
  • 6. Serialized Circuit Boards We serialize and track all critical circuit boards and memory cards through our eBOSS portal, which allows customers to reference which components their machines are made from, who tested the components, as well as the ability to view notes generated from testing. Serialized components offer the ability to drill-down on prospective component failure utilizing predictive modeling techniques, so if part fails, the instance can be cross-referenced with similar parts. This preventative maintenance helps ensure maximum uptime. Silver Plated Terminals LayerZero utilizes silver plating on all input terminals to be able to provide the highest performance. Silver has high conductivity and low resistance - which makes for a great contact. Web-Enabled Distribution PanelSeries 70 eRDP 6 © Copyright 2016 LayerZero Power Systems, Inc. Reliability Features
  • 7. 77 Scan Bolted Connections with Dead-Front Doors Closed Strategically positioned IR-scan portholes to enable safe thermal scanning of all bolted connections with the deadfront closed, without exposing the operator to power circuit voltage. The IR window swivels upward and unlocks with key-hole access to reveal a mesh, allowing the operator to point-and-shoot thermal cameras to obtain accurate readings. LayerZero provides documentation for proper thermal scanning procedures. View CB Positions With Dead-Front Doors Closed The Series 70: eRDP is equipped with polycarbonate windows located on the outer door of the subfeed circuit breaker section. Circuit breaker positions can be viewed with the dead-front door closed. Web-Enabled Distribution PanelSeries 70 eRDP 7 © Copyright 2016 LayerZero Power Systems, Inc. Safety Features/Ease of Maintenance
  • 8. 88 Guided Wireways Help keep cables and wiring organized with our guided wireways and cable clips. Sectionalization Maximizes Operator Safety Operators are well-protected from exposed connections. Normal operator sections (breakers/switches) are physically separated from the power electronics and control electronics sections, so that maintenance on a section can be safely performed. If maintenance is required on a particular section, power can be bypassed to another section to allow for safe repairs to be made. After installation, there is no need to open the eRDP left cabinet. Web-Enabled Distribution PanelSeries 70 eRDP 8 © Copyright 2016 LayerZero Power Systems, Inc. Safety Features/Ease of Maintenance
  • 9. The Breaker Is Inserted Into The SafePanel The Handle Is Unlocked Screws Help Secure The Breaker For Maximum Safety, The SafePanel Has Recessed Bus Work and Finger Safe Lattice. eRDP 1200 A Circuit Breaker Installation Process The LayerZero SafePanel™ The Series 70 eRDP features an IP-20, finger-safe panel board, meaning that the opening will not allow ingress of ½” (12.5mm) diameter probe, for maximum operator safety. An arc can form as two live conductors are separated – such as the removal of a circuit breaker from a panel board. The SafePanel design ensures that a potential arc would be contained in the connection well so that even if a branch breaker were to be removed, the arc would be contained in the connection well. Insulated with the components deeply isolated, removal of the breaker is safe and easy. Web-Enabled Distribution PanelSeries 70 eRDP 9 © Copyright 2016 LayerZero Power Systems, Inc. Safety Features
  • 10. Modbus/TCP http:// through a standard web browser Simple Network Management Protocol (SNMP) Standard Ethernet Dry Contacts • Meters • Alarms • Alarms • Alarms• Panel Setup • Meters • Alarms • Waveforms • History/Event Log • Diagnostics Series 70 eRDP Bluetooth Keeps Circuit Level Information Up-To-Date Coordinate efforts to keep panel board naming conventions accurate and up-to-date with Bluetooth connectivity. In critical facilities, Facilities typically install the physical circuit breakers, while IT workers manage naming of panel designations. With Bluetooth connectivity, the naming, size, and assignment of circuit breakers can be taken care of at the point-of-impact, bringing together the efforts of facilities and IT for more accurate deployment. Web-Enabled Distribution PanelSeries 70 eRDP 10 © Copyright 2016 LayerZero Power Systems, Inc. Connectivity Options
  • 11. The Series 70 eRPP is equipped with Zen DPQM (Distribution Power Quality Monitoring), an all encompassing monitoring system with local and remote communications options. From basic monitoring & alarm reporting, to advanced power quality monitoring functionality, Zen DPQM provides a wide-range of options to help you be aware, be vigilant, be proactive in your quest to create a safe, stable and reliable operation. Zen DPQM Provides Answers Zen DPQM provides timestamped pictures of waveforms before and after events, providing information that enables facilities to go back in time to methodically identify and correct the root causes of events. Zen actively captures power quality information at the STS, PDU, and RPP - permitting thorough post-event analysis. 6 Electrical Cycles 6 Electrical Cycles Waveform Capture of Power Quality Issue Trigger Event Phase A Phase B Phase C Web-Enabled Distribution PanelSeries 70 eRDP 11 © Copyright 2016 LayerZero Power Systems, Inc. Power Quality Monitoring
  • 12. PBM MCB (Optional - Not Displayed) Inputs Sub-Feeds PBM Sub-Feeds A V PQ Current Metering Point Voltage Metering Point Power Quality Metering Point BM Branch Current Monitoring Web-Enabled Distribution PanelSeries 70 eRDP 12 © Copyright 2016 LayerZero Power Systems, Inc. Power Quality Monitoring
  • 13. Zen DPQM Parameters Mains Subfeeds or Branch Circuits Voltage Monitor Volts (L-L) Phase A/B/C (volts RMS) Volts (L-N) Phase A/B/C (volts RMS) Phase Rotation Current Monitor CT Reversed Phase A/B/C/N Current Phase A/B/C/N (amperes RMS) Power Monitor Frequency (hertz) Real Power (kilowatts) Apparent Power (kilovolt-amperes) Reactive Power (kilovolt-amperes reactive) Power Factor Energy (kilowatt-hours) Block Demand (kilowatts) Block Demand Peak (kilowatts) Rolling Demand (kilowatts) Rolling Demand Peak (kilowatts) Power Quality Percent VTHD (percent) Waveform Capture Alarms Phase - Under Voltage A/B/C (Alarm) Phase - Over Voltage A/B/C (Alarm) Phase - Low Voltage A/B/C (Warning) Phase - High Voltage A/B/C (Warning) Phase - Over Current A/B/C (Alarm) Phase - High Current A/B/C (Warning) Under Frequency (Alarm) Over Frequency (Alarm) High VTHD (Warning) Over VTHD (Alarm) Phase Rotation (Alarm) All product specifications are subject to change without notice. Web-Enabled Distribution PanelSeries 70 eRDP 13 © Copyright 2016 LayerZero Power Systems, Inc. Technical Specifications
  • 14. eRDP Models with System Withstand Ratings 120/208V, 3-Phase, 4-Wire + Ground 100 kA 220/380V, 3-Phase, 4-Wire + Ground 65 kA 230/400V, 3-Phase, 4-Wire + Ground 240/415V, 3-Phase, 4-Wire + Ground 277/480V, 3-Phase, 4-Wire + Ground 480V, 3-Phase, 3-Wire + Ground 575V, 3-Phase, 3-Wire + Ground 42 kA 600V, 3-Phase, 3-Wire + Ground Mechanical Characteristics Dimensions 47”W x 89”H x 18”D (1194 mm x 2260 mm x 457 mm) Weight 912 lbs (414 kg) Enclosure Mounting Wall-Mounted Frame Construction Welded Frame Electrical Connections Flexible Laminated Bus, Silver-Plated Solid Busbar Color Textured Powder Coat White (RAL 7035), Blue (RAL 5017), Black, Custom Seismic Floor Anchors Optional Seismic Floor Stand Optional Sectionalization Engineered Composite Insulation, Dead Front Doors Circuit Breaker Identification Labels Viewable Through Polycarbonate Window Electrical Characteristics Input Voltage 120/208V, 3-Phase, 4-Wire + Ground; 220/380V, 3-Phase, 4-Wire + Ground; 230/400V, 3-Phase, 4-Wire + Ground; 240/415V, 3-Phase, 4-Wire + Ground; 277/480V, 3-Phase, 4-Wire + Ground; 480V, 3-Phase, 3-Wire + Ground; 575V, 3-Phase, 3-Wire + Ground; 600V, 3-Phase, 3-Wire + Ground Withstand 100 kA Configuration Parallel (P), Shared Parallel (SP), Dedicated (D), Feed Through (FT) Frequency 50 Hz, 60 Hz Poles 3-pole, 4-pole Neutral Rating 100%, 200% Circuit Breaker Type Electronic Trip, Molded Case Switch Distribution SafePanel™ Distribution Power Quality Monitoring Power Quality Monitoring Technology Zen DPQM™ (Distribution Power Quality Monitoring) Waveform Capture Local Display, Remote Display via Web Browser All product specifications are subject to change without notice. Web-Enabled Distribution PanelSeries 70 eRDP 14 © Copyright 2016 LayerZero Power Systems, Inc. Technical Specifications
  • 15. Operational Characteristics Cooling Convection Cooling Cable Access Top/Bottom Service Access Front Only Access IR Scan Port Type InSight™ IR Portholes Display Type 3.2” LCD with Membrane, 10.5” Color Touch Screen GUI (Optional) Connectivity Meters Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary) Alarms Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary) Summary Alarm Dry Contacts Waveforms Local Display, Ethernet, http via Web Browser (Non-Proprietary) History/Event Log Local Display, Ethernet, http via Web Browser (Non-Proprietary) Diagnostics Local Display, Ethernet, http via Web Browser (Non-Proprietary) Time Synchronization Network Time Protocol (NTP) Standards Conformance UL ETL and cETL listed to UL 60950 Number of Output Circuit Breakers Number of Available SafePanel™ Slots 36 CB Rating Number of Slots Required 100 AF 2 250 AF 3 400 AF 3 400 AF 100% 6 800 AF 6 All product specifications are subject to change without notice. 36 Total Available Slots 1 Slot 2 Slots 3 Slots 6 Slots Universal Dead FrontSafePanel™ Panel Board Interchangeable Plates Fit All CB Sizes Blank Plates Web-Enabled Distribution PanelSeries 70 eRDP 15 © Copyright 2016 LayerZero Power Systems, Inc. Technical Specifications
  • 16. LayerZero Power Systems, Inc. 1500 Danner Drive Aurora, OH 44202 U.S.A. © 2016 LayerZero Power Systems, Inc. LayerZero Power Systems, LayerZero.com and the LayerZero logo are registered trademark of LayerZero. All product specifications are subject to change without notice. Learn more at www.LayerZero.com Rev. 7/16 #16