LubeRight system
IS DEVELOPEMENT STALLING?
Grease Meter
With display showing the volume fed.
LubeRight system
Grease Handling
Filling grease from barrel, clean and airless
Lubricating with proper equipment
1300
1250
1000
650
0
200
400
600
800
1000
1200
1400
KG
1996 1997 1998 1999
A reduction of 50 % of grease used was achieved in the
machine hall. In addition spare part costs went down.
In 1999 the Grease Meter was used with all manual lubrication.
In 1997 MoDo in Ornskoldsvik aquired their first Grease Meter.
Identification of the greasing point by
RFID (Radio-Frequency Identification)
• Works in
polluted
environments
• Correct reading
distance
• Name
• Group
• Lubricant amount
• Interval
• Lubricant
REGISTRATION OF GREASING POINTS
• THE AMOUNT OF
GREASE REQUIRED IS
SHOWN ON THE
DISPLAY
• THE REAL AMOUNT
FED INTO THE
GREASING POINT
WILL BE REGISTRED
BY THE METER
The Performed Lubrication is Transferred
from the Meter to the Computer
• Which points
have been
lubricated.
LubeRight OFFERS TOTAL CONTROL OF
EVERY SINGLE GREASING POINT
AVAILABLE
INFORMATION:
• Which points
have been
forgotten.
• How much.
• When.
Digital grease meter with antenna for communication with lubrication
nipples. The grease meter has a contact for connection to the power
supply and communication unit.
Data
Max. pressure 70 MPa
Grease connection int. ISO-G1/8
Weight 0.8 kg
Hose length 400 mm
Flow range0-1000 cm³/min.
Accuracy +/- 3 % up to 300 bar
Protection IP54
Temp. range -20 °C - +40 °C
GREASE METER
• The grease meter is equipped with a resettable total counter.
• It can be calibrated and can show the grease amounts in cm³, g, oz. or
fl. oz.
• The display of the grease meter is equipped with a backlight for use in
dark working environments.
Communication
The unit is connected between the grease meter and the PC
when information needs to be transferred.
Charging
Charging takes approx. 15 hours.
Data
Supply voltage 100-230 VAC 50-60 Hz
Power max 0.25 A
Output voltage 5 VDC 2.0 A
Protection IP20
Weight 0.8 kg
Power Supply and Communication Unit
• The transponder has a unique number that the
grease meter identifies.
• Stiffening plate and locking ring in acidproof steel.
Lubrication nipple in zinc plated or acid proof steel.
• Transponder in epoxy.
• Connection thread: ISO-G1/8 or NPT 1/8
• Type of lubrication nipple in accordance with
DIN 71412
• Temperature range: -40 °C to +85 °C
Lubrication Nipple with Transponder

More Related Content

PDF
LPG-filters
PDF
Control Station - ATEX - Emergency Stop - Red Mushroom Pushbutton (Pull) - Wa...
PDF
Control Stations (GRP) Hazardous Area - Ammeter - Walsall LCP160
PDF
Norton R976 belts - Brochure
PDF
ROTARYPRESS_EN
PDF
Monforts italian producers_reap_benefits_of_monforts1_2_0
PDF
STM Environment
PPTX
Miscellaneous Test Equipment
LPG-filters
Control Station - ATEX - Emergency Stop - Red Mushroom Pushbutton (Pull) - Wa...
Control Stations (GRP) Hazardous Area - Ammeter - Walsall LCP160
Norton R976 belts - Brochure
ROTARYPRESS_EN
Monforts italian producers_reap_benefits_of_monforts1_2_0
STM Environment
Miscellaneous Test Equipment

Recently uploaded (20)

PPTX
Slide gioi thieu VietinBank Quy 2 - 2025
PDF
Charisse Litchman: A Maverick Making Neurological Care More Accessible
PDF
PMB 401-Identification-of-Potential-Biotechnological-Products.pdf
PDF
Satish NS: Fostering Innovation and Sustainability: Haier India’s Customer-Ce...
PPTX
operations management : demand supply ch
PDF
Introduction to Generative Engine Optimization (GEO)
PDF
Ron Thomas - Top Influential Business Leaders Shaping the Modern Industry – 2025
PDF
income tax laws notes important pakistan
DOCX
Center Enamel A Strategic Partner for the Modernization of Georgia's Chemical...
DOCX
Center Enamel Powering Innovation and Resilience in the Italian Chemical Indu...
PDF
TyAnn Osborn: A Visionary Leader Shaping Corporate Workforce Dynamics
PPTX
svnfcksanfskjcsnvvjknsnvsdscnsncxasxa saccacxsax
PPTX
Astra-Investor- business Presentation (1).pptx
PDF
Family Law: The Role of Communication in Mediation (www.kiu.ac.ug)
PDF
Booking.com The Global AI Sentiment Report 2025
PDF
Kishore Vora - Best CFO in India to watch in 2025.pdf
DOCX
FINALS-BSHhchcuvivicucucucucM-Centro.docx
PPTX
chapter 2 entrepreneurship full lecture ppt
DOCX
Hand book of Entrepreneurship 4 Chapters.docx
PDF
Tortilla Mexican Grill 发射点犯得上发射点发生发射点犯得上发生
Slide gioi thieu VietinBank Quy 2 - 2025
Charisse Litchman: A Maverick Making Neurological Care More Accessible
PMB 401-Identification-of-Potential-Biotechnological-Products.pdf
Satish NS: Fostering Innovation and Sustainability: Haier India’s Customer-Ce...
operations management : demand supply ch
Introduction to Generative Engine Optimization (GEO)
Ron Thomas - Top Influential Business Leaders Shaping the Modern Industry – 2025
income tax laws notes important pakistan
Center Enamel A Strategic Partner for the Modernization of Georgia's Chemical...
Center Enamel Powering Innovation and Resilience in the Italian Chemical Indu...
TyAnn Osborn: A Visionary Leader Shaping Corporate Workforce Dynamics
svnfcksanfskjcsnvvjknsnvsdscnsncxasxa saccacxsax
Astra-Investor- business Presentation (1).pptx
Family Law: The Role of Communication in Mediation (www.kiu.ac.ug)
Booking.com The Global AI Sentiment Report 2025
Kishore Vora - Best CFO in India to watch in 2025.pdf
FINALS-BSHhchcuvivicucucucucM-Centro.docx
chapter 2 entrepreneurship full lecture ppt
Hand book of Entrepreneurship 4 Chapters.docx
Tortilla Mexican Grill 发射点犯得上发射点发生发射点犯得上发生
Ad
Ad

LubeRight system

  • 1. A new amazing product!
  • 2. SOFTWARE GREASING NIPPLE WITH TAG (TRANSPONDER) COMMUNICATION AND CHARGING UNIT GREASE METER
  • 6. Grease Meter With display showing the volume fed.
  • 8. Grease Handling Filling grease from barrel, clean and airless Lubricating with proper equipment
  • 9. 1300 1250 1000 650 0 200 400 600 800 1000 1200 1400 KG 1996 1997 1998 1999 A reduction of 50 % of grease used was achieved in the machine hall. In addition spare part costs went down. In 1999 the Grease Meter was used with all manual lubrication. In 1997 MoDo in Ornskoldsvik aquired their first Grease Meter.
  • 10. Identification of the greasing point by RFID (Radio-Frequency Identification) • Works in polluted environments • Correct reading distance
  • 11. • Name • Group • Lubricant amount • Interval • Lubricant REGISTRATION OF GREASING POINTS
  • 12. • THE AMOUNT OF GREASE REQUIRED IS SHOWN ON THE DISPLAY • THE REAL AMOUNT FED INTO THE GREASING POINT WILL BE REGISTRED BY THE METER
  • 13. The Performed Lubrication is Transferred from the Meter to the Computer
  • 14. • Which points have been lubricated. LubeRight OFFERS TOTAL CONTROL OF EVERY SINGLE GREASING POINT AVAILABLE INFORMATION: • Which points have been forgotten. • How much. • When.
  • 15. Digital grease meter with antenna for communication with lubrication nipples. The grease meter has a contact for connection to the power supply and communication unit. Data Max. pressure 70 MPa Grease connection int. ISO-G1/8 Weight 0.8 kg Hose length 400 mm Flow range0-1000 cm³/min. Accuracy +/- 3 % up to 300 bar Protection IP54 Temp. range -20 °C - +40 °C GREASE METER • The grease meter is equipped with a resettable total counter. • It can be calibrated and can show the grease amounts in cm³, g, oz. or fl. oz. • The display of the grease meter is equipped with a backlight for use in dark working environments.
  • 16. Communication The unit is connected between the grease meter and the PC when information needs to be transferred. Charging Charging takes approx. 15 hours. Data Supply voltage 100-230 VAC 50-60 Hz Power max 0.25 A Output voltage 5 VDC 2.0 A Protection IP20 Weight 0.8 kg Power Supply and Communication Unit
  • 17. • The transponder has a unique number that the grease meter identifies. • Stiffening plate and locking ring in acidproof steel. Lubrication nipple in zinc plated or acid proof steel. • Transponder in epoxy. • Connection thread: ISO-G1/8 or NPT 1/8 • Type of lubrication nipple in accordance with DIN 71412 • Temperature range: -40 °C to +85 °C Lubrication Nipple with Transponder