The hemocytometer (or
hemocytometer) is a counting-
chamber device originally designed
and usually used for counting
blood cells. A hemocytometer. The
two semi-reflective rectangles are
the counting chambers.
manual cell count
1
A manual cell count of a blood specimen, also
known as a peripheral blood smear (PBS), is a
microscopic examination of blood stained on a
glass slide. It is used to:
1. Count the different types of white blood
cells (WBCs). This is called a differential
white blood cell count.
2. Examine the size and shape of red blood
cells (RBCs).
3. Look for abnormal cells, such as immature
blood cells or cancer cells.
manual cell count 2
A PBS is a more time-consuming
and labor-intensive test than
automated blood cell counts, but it
can provide more information
about the types and morphology of
blood cells. It is often used in
conjunction with automated blood
cell counts to investigate abnormal
results or to diagnose certain
conditions.
manual cell count 3
Here are the steps involved in performing a
manual cell count of a blood specimen:
1.Prepare a blood smear. A small drop of blood is
placed on a glass slide and spread into a thin
film. The slide is then stained with special dyes to
make the cells easier to see under a microscope.
2.Examine the slide under a microscope. A
trained technician will examine the slide under a
microscope to count the different types of white
blood cells and examine the size and shape of the
red blood cells.
3.Report the results. The technician will report the
results of the cell count to the doctor.
manual cell count 4
While still used in some cases,
manual cell counts are becoming
less common as automated blood
cell counters become more
sophisticated. However, they are
still an important tool for
diagnosing certain conditions.
manual cell count 5
a hemocytometer is the primary
tool used for manual cell counts in
blood specimens. It's essentially a
specialized microscope slide with a
precise, shallow chamber etched
with a grid. This grid allows for
accurate counting of cells
suspended in a known volume of
liquid.
Here's a closer look at
hemocytometers:
Hemocytometer microscope slide
manual cell count 6
manual cell count 7
manual cell count 8
Components:
•Counting chamber: This is the rectangular
indentation where the cell suspension is loaded. It
has a specific depth and volume (usually 10
microliters).
•Cover slip: This thin glass plate is placed over the
counting chamber to create a sealed chamber and
ensure even distribution of the cell suspension.
•Etched grid: The grid is typically divided into
several smaller squares, with specific areas
designated for counting different types of
cells. For example, the Neubauer improved
hemocytometer, a common type, has a large
central area with 16 squares further divided into
16 smaller squares each.
How it works:
1.Prepare the hemocytometer: Clean the
chamber and coverslip and ensure proper
adhesion.
2.Load the cell suspension: Carefully pipette a
known volume of the diluted cell suspension into
the counting chamber. Capillary action will draw
the liquid in.
3.Count the cells: Using a microscope with the
appropriate objective (usually 10x or
40x), systematically count the cells within the
designated grid areas according to the type of cell
being counted.
4.Calculate the cell concentration: Use the
counted number of cells, the grid area, and the
loaded volume to calculate the cell concentration
per unit volume (e.g., cells/mL).
Components:
•Counting chamber: This is the rectangular indentation where the cell
suspension is loaded. It has a specific depth and volume (usually 10
microliters).
•Cover slip: This thin glass plate is placed over the counting chamber to create
a sealed chamber and ensure even distribution of the cell suspension.
•Etched grid: The grid is typically divided into several smaller squares, with
specific areas designated for counting different types of cells. For example, the
Neubauer improved hemocytometer, a common type, has a large central area
with 16 squares further divided into 16 smaller squares each.
How it works:
1.Prepare the hemocytometer: Clean the chamber and coverslip and ensure
proper adhesion.
2.Load the cell suspension: Carefully pipette a known volume of the diluted
cell suspension into the counting chamber. Capillary action will draw the liquid
in.
3.Count the cells: Using a microscope with the appropriate objective (usually
10x or 40x), systematically count the cells within the designated grid areas
according to the type of cell being counted.
4.Calculate the cell concentration: Use the counted number of cells, the grid
area, and the loaded volume to calculate the cell concentration per unit
volume (e.g., cells/mL).
manual cell count 9
Advantages of using a
hemocytometer:
•Relatively inexpensive and
readily available.
•Provides detailed information on
cell morphology and types.
•Useful for low cell count samples.
Disadvantages of using a
hemocytometer:
•Time-consuming and labor-
intensive.
•Requires skill and experience for
accurate counting.
•More prone to errors compared
to automated methods.
manual cell count 10
Overall, hemocytometers remain
valuable tools for manual cell
counting in various applications,
including blood analysis, cell
culture experiments, and
environmental monitoring.
manual cell count 11
Using a Hemocytometer in Four Simple
Steps
1. Dilute Your Sample with Trypan blue
Trypan blue is a stain that allows you to
distinguish dead cells from living cells.
When mixed with your cell sample, any
dead cells will be stained blue by the dye,
meaning that you can count only those
cells that are living and viable.
You can dilute your sample with trypan
blue at any ratio, but a 1:1 ratio is the most
common. Whatever dilution you use, make
sure to note it down as you’ll need this for
your final calculation.
manual cell count 12
2. Loading the Hemocytometer
Before you get started, ensure that both the
hemocytometer and its coverslip are clean by
removing any dust particles with lens paper.
Coverslips used for mounting on hemocytometers
are specially made to be thicker than conventional
microscopy coverslips because they must be able
to overcome the surface tension of a drop of liquid.
Make sure you place the coverslip over the counting
surface before loading the cell suspension. Then
place the pipette tip with your sample into one of
the V-shaped wells, and gently expel the sample.
The area under the coverslip fills by capillary action.
Enough liquid should be introduced so that the
mirrored surface is just covered, usually around 10
µl, but don’t overfill the surface. You can load two
samples on one hemocytometer, one into each of
the two grids.
manual cell count 13
The loaded hemocytometer
is then placed on the
microscope stage and the
counting grid is brought into
focus at low power. Allow the
sample to settle for a couple
of minutes and avoid
moving the coverslip as it
might introduce air bubbles
and make counting difficult.
manual cell count 14
. Counting Cells in a Hemocytometer
The full grid on a hemocytometer contains
nine squares, each of which is 1 mm2 The
central counting area of the
hemocytometer contains 25 large squares
and each large square has 16 smaller
squares.
When counting cells that overlap an
exterior line or ruling, count only those cells
on the top or right-hand line of the large
square to avoid counting cells twice.
Suspensions should be dilute enough so
that the cells or other particles do not
overlap each other on the grid, and should
be uniformly distributed.
manual cell count 15
To perform the count,
determine the magnification
needed to recognize the
desired cell type and
systematically count the
cells in selected squares so
that the total count is
approximately 100 cells, a
minimum number of cells
needed for a statistically
significant count.
manual cell count 16
For large cells, you can simply count the
cells inside the four large corner squares
and the middle square For a dense
suspension of small cells, you may wish
to count the cells in the four outer and
middle squares of the central square or
make a more dilute suspension.
Remember if a cell overlaps a line, count
it as “in” if it overlaps the top or right-
hand line and “out” if it overlaps the
bottom or left-hand line
manual cell count 17
The area of the middle and each corner
square is 1 mm x 1 mm = 1 mm2. The depth
of each square is 0.1 mm. Hence, the final
volume of each square at that depth is
100 nl.
manual cell count 18
Calculating Cell Concentration
You can calculate your cell concentration
using the following formula:
Total cells/ml = (Total cells counted x
Dilution factor x 10,000 cells/ml)/
Number of squares counted
So, for example, if you diluted your sample
1:1 with Trypan blue (dilution factor is 2 in
this case), and you counted 325 cells in
the four corner squares plus the central
big square (number of squares counted is
5), then:
Total cells/ml = (325 cells x 2 x 10,000
cells/ml)/ 5 = 130 x 104 cells/ml
manual cell count 19
If you want to know how
many cells you have in your
original sample, just multiply
the cell concentration by the
total sample volume. For
example, if your original
sample volume is 5 ml, then:
Total cells in sample = 130 x
104 cells/ml x 5 ml = 650 x
104 cells
manual cell count 20

More Related Content

PPT
recent advances in hemoparasites
PPTX
Laboratory Approach to coagulation disorders & Mixing studies
PPT
Donor selection
PPTX
Automation in blood banking
PPTX
Blood component preparation blood banking
PPTX
Calibration and Quality controls of automated hematology analyzer
PPT
Histokinetic by dr narmada
PPT
Automated Urine Analysis
recent advances in hemoparasites
Laboratory Approach to coagulation disorders & Mixing studies
Donor selection
Automation in blood banking
Blood component preparation blood banking
Calibration and Quality controls of automated hematology analyzer
Histokinetic by dr narmada
Automated Urine Analysis

What's hot (20)

PPTX
Automated cell counter & its quality control
PPT
OTHER BLOOD GROUP SYSTEMS
PDF
CYTOLOGY AND CYTOGENITICS MCQS BY IKRAM ULLAH
PPTX
Bleeding tests
PDF
HEMATOPOIETIC STEM CELL TRANSPLANTS IN PEDIATRIC by DR ABHIJEET MANOHAR WANKHEDE
PPTX
LABORATORY INVESTIGATION OF TRANSFUSION REACTION CASES
PPT
Pre transfusion testing, dr. rafiq
PDF
PPTX
Discrepancies
PPTX
Microscopic examination of urine
PPTX
Automation in hematology
PPTX
special stains in hematology and cytology
PPTX
Introduction to Histopathology and Lab organization.pptx
PPTX
Gel card technology ppt nc
PPTX
quality control in clinical pathology
PDF
Introduction to Apheresis (Dr. Nashwa Elsayed)
PPTX
Raju automation Msc MLT PATHOLOGY
PPTX
Amna sahar
PDF
Pre and Post Analytical Errors
PPTX
Automation in cytology.
Automated cell counter & its quality control
OTHER BLOOD GROUP SYSTEMS
CYTOLOGY AND CYTOGENITICS MCQS BY IKRAM ULLAH
Bleeding tests
HEMATOPOIETIC STEM CELL TRANSPLANTS IN PEDIATRIC by DR ABHIJEET MANOHAR WANKHEDE
LABORATORY INVESTIGATION OF TRANSFUSION REACTION CASES
Pre transfusion testing, dr. rafiq
Discrepancies
Microscopic examination of urine
Automation in hematology
special stains in hematology and cytology
Introduction to Histopathology and Lab organization.pptx
Gel card technology ppt nc
quality control in clinical pathology
Introduction to Apheresis (Dr. Nashwa Elsayed)
Raju automation Msc MLT PATHOLOGY
Amna sahar
Pre and Post Analytical Errors
Automation in cytology.
Ad

Similar to manual cell count.pdf (20)

PPTX
Haemocytometer ppt animal cell culture
PPT
Hemocytometer manual cell counting (1)
PPTX
HEmocytometry.pptx
PPT
Hema I Chapter 7_hemocytometry.ppt
PDF
Total Leukocyte Count By Hemocytometer
PPTX
ACT .pptx
PDF
Direct microscope method
PPTX
Haemocytometry
PPTX
Hemocytometer
PPTX
Demonstration of Hemocytometer Power point
PPTX
Enumeration of Red Blood Cells
PDF
Practical Hematology l 01 Manual CBC.pdf
PDF
Total Erythrocyte Count By Hemocytometer
PDF
Hemocytometry
PPSX
Red blood cell count
PDF
Total leukocyte count by hemocytometer
DOCX
Total Leukocyte Count by Hemocytometer
PDF
Manual Total Leucocyte Count Sop
PPTX
Redbloodcellcount 131025052708-phpapp02.ppsx
DOCX
Methods of measuring microbial growth
Haemocytometer ppt animal cell culture
Hemocytometer manual cell counting (1)
HEmocytometry.pptx
Hema I Chapter 7_hemocytometry.ppt
Total Leukocyte Count By Hemocytometer
ACT .pptx
Direct microscope method
Haemocytometry
Hemocytometer
Demonstration of Hemocytometer Power point
Enumeration of Red Blood Cells
Practical Hematology l 01 Manual CBC.pdf
Total Erythrocyte Count By Hemocytometer
Hemocytometry
Red blood cell count
Total leukocyte count by hemocytometer
Total Leukocyte Count by Hemocytometer
Manual Total Leucocyte Count Sop
Redbloodcellcount 131025052708-phpapp02.ppsx
Methods of measuring microbial growth
Ad

More from Mohamed Alashram (20)

PDF
history of software engineering .pdf
PDF
history of software engineering .pdf
PDF
degrees of computer science. pdf
PDF
history of hardware. pdf
PDF
📚 Practical Virology from Scratch-study guidepdf.pdf
PDF
horse-identification. pdf
PDF
horse-gait. pdf
PDF
horse-breeds- .pdf
PDF
horse health horse-breeds. pdf
PDF
HORSE-BEHAVIOUR. pdf
PDF
horse health horse approach. pdf
PDF
horse health horse-age .pdf
PDF
horse health hoof-care .pdf
PDF
introduction horse health course .pdf
PDF
avian vaccine and vaccination failure.pdf
DOCX
ophthalmic history taking1 .docx
PDF
Examination of the Visual System .pdf
PDF
Equine Viral Diseases. pdf
PDF
global business technology in business.pdf
PDF
management and business. pdf
history of software engineering .pdf
history of software engineering .pdf
degrees of computer science. pdf
history of hardware. pdf
📚 Practical Virology from Scratch-study guidepdf.pdf
horse-identification. pdf
horse-gait. pdf
horse-breeds- .pdf
horse health horse-breeds. pdf
HORSE-BEHAVIOUR. pdf
horse health horse approach. pdf
horse health horse-age .pdf
horse health hoof-care .pdf
introduction horse health course .pdf
avian vaccine and vaccination failure.pdf
ophthalmic history taking1 .docx
Examination of the Visual System .pdf
Equine Viral Diseases. pdf
global business technology in business.pdf
management and business. pdf

Recently uploaded (20)

PDF
MBA _Common_ 2nd year Syllabus _2021-22_.pdf
PPTX
Share_Module_2_Power_conflict_and_negotiation.pptx
PDF
CRP102_SAGALASSOS_Final_Projects_2025.pdf
PPTX
Climate Change and Its Global Impact.pptx
PDF
International_Financial_Reporting_Standa.pdf
PDF
Hazard Identification & Risk Assessment .pdf
PDF
Race Reva University – Shaping Future Leaders in Artificial Intelligence
PDF
Empowerment Technology for Senior High School Guide
PDF
CISA (Certified Information Systems Auditor) Domain-Wise Summary.pdf
PDF
Skin Care and Cosmetic Ingredients Dictionary ( PDFDrive ).pdf
PDF
FOISHS ANNUAL IMPLEMENTATION PLAN 2025.pdf
PPTX
B.Sc. DS Unit 2 Software Engineering.pptx
PDF
BP 505 T. PHARMACEUTICAL JURISPRUDENCE (UNIT 2).pdf
PDF
Vision Prelims GS PYQ Analysis 2011-2022 www.upscpdf.com.pdf
PDF
LEARNERS WITH ADDITIONAL NEEDS ProfEd Topic
PDF
BP 704 T. NOVEL DRUG DELIVERY SYSTEMS (UNIT 1)
PDF
1.3 FINAL REVISED K-10 PE and Health CG 2023 Grades 4-10 (1).pdf
PDF
Complications of Minimal Access-Surgery.pdf
PPTX
Introduction to pro and eukaryotes and differences.pptx
PPTX
Unit 4 Computer Architecture Multicore Processor.pptx
MBA _Common_ 2nd year Syllabus _2021-22_.pdf
Share_Module_2_Power_conflict_and_negotiation.pptx
CRP102_SAGALASSOS_Final_Projects_2025.pdf
Climate Change and Its Global Impact.pptx
International_Financial_Reporting_Standa.pdf
Hazard Identification & Risk Assessment .pdf
Race Reva University – Shaping Future Leaders in Artificial Intelligence
Empowerment Technology for Senior High School Guide
CISA (Certified Information Systems Auditor) Domain-Wise Summary.pdf
Skin Care and Cosmetic Ingredients Dictionary ( PDFDrive ).pdf
FOISHS ANNUAL IMPLEMENTATION PLAN 2025.pdf
B.Sc. DS Unit 2 Software Engineering.pptx
BP 505 T. PHARMACEUTICAL JURISPRUDENCE (UNIT 2).pdf
Vision Prelims GS PYQ Analysis 2011-2022 www.upscpdf.com.pdf
LEARNERS WITH ADDITIONAL NEEDS ProfEd Topic
BP 704 T. NOVEL DRUG DELIVERY SYSTEMS (UNIT 1)
1.3 FINAL REVISED K-10 PE and Health CG 2023 Grades 4-10 (1).pdf
Complications of Minimal Access-Surgery.pdf
Introduction to pro and eukaryotes and differences.pptx
Unit 4 Computer Architecture Multicore Processor.pptx

manual cell count.pdf

  • 1. The hemocytometer (or hemocytometer) is a counting- chamber device originally designed and usually used for counting blood cells. A hemocytometer. The two semi-reflective rectangles are the counting chambers. manual cell count 1
  • 2. A manual cell count of a blood specimen, also known as a peripheral blood smear (PBS), is a microscopic examination of blood stained on a glass slide. It is used to: 1. Count the different types of white blood cells (WBCs). This is called a differential white blood cell count. 2. Examine the size and shape of red blood cells (RBCs). 3. Look for abnormal cells, such as immature blood cells or cancer cells. manual cell count 2
  • 3. A PBS is a more time-consuming and labor-intensive test than automated blood cell counts, but it can provide more information about the types and morphology of blood cells. It is often used in conjunction with automated blood cell counts to investigate abnormal results or to diagnose certain conditions. manual cell count 3
  • 4. Here are the steps involved in performing a manual cell count of a blood specimen: 1.Prepare a blood smear. A small drop of blood is placed on a glass slide and spread into a thin film. The slide is then stained with special dyes to make the cells easier to see under a microscope. 2.Examine the slide under a microscope. A trained technician will examine the slide under a microscope to count the different types of white blood cells and examine the size and shape of the red blood cells. 3.Report the results. The technician will report the results of the cell count to the doctor. manual cell count 4
  • 5. While still used in some cases, manual cell counts are becoming less common as automated blood cell counters become more sophisticated. However, they are still an important tool for diagnosing certain conditions. manual cell count 5
  • 6. a hemocytometer is the primary tool used for manual cell counts in blood specimens. It's essentially a specialized microscope slide with a precise, shallow chamber etched with a grid. This grid allows for accurate counting of cells suspended in a known volume of liquid. Here's a closer look at hemocytometers: Hemocytometer microscope slide manual cell count 6
  • 8. manual cell count 8 Components: •Counting chamber: This is the rectangular indentation where the cell suspension is loaded. It has a specific depth and volume (usually 10 microliters). •Cover slip: This thin glass plate is placed over the counting chamber to create a sealed chamber and ensure even distribution of the cell suspension. •Etched grid: The grid is typically divided into several smaller squares, with specific areas designated for counting different types of cells. For example, the Neubauer improved hemocytometer, a common type, has a large central area with 16 squares further divided into 16 smaller squares each. How it works: 1.Prepare the hemocytometer: Clean the chamber and coverslip and ensure proper adhesion. 2.Load the cell suspension: Carefully pipette a known volume of the diluted cell suspension into the counting chamber. Capillary action will draw the liquid in. 3.Count the cells: Using a microscope with the appropriate objective (usually 10x or 40x), systematically count the cells within the designated grid areas according to the type of cell being counted. 4.Calculate the cell concentration: Use the counted number of cells, the grid area, and the loaded volume to calculate the cell concentration per unit volume (e.g., cells/mL).
  • 9. Components: •Counting chamber: This is the rectangular indentation where the cell suspension is loaded. It has a specific depth and volume (usually 10 microliters). •Cover slip: This thin glass plate is placed over the counting chamber to create a sealed chamber and ensure even distribution of the cell suspension. •Etched grid: The grid is typically divided into several smaller squares, with specific areas designated for counting different types of cells. For example, the Neubauer improved hemocytometer, a common type, has a large central area with 16 squares further divided into 16 smaller squares each. How it works: 1.Prepare the hemocytometer: Clean the chamber and coverslip and ensure proper adhesion. 2.Load the cell suspension: Carefully pipette a known volume of the diluted cell suspension into the counting chamber. Capillary action will draw the liquid in. 3.Count the cells: Using a microscope with the appropriate objective (usually 10x or 40x), systematically count the cells within the designated grid areas according to the type of cell being counted. 4.Calculate the cell concentration: Use the counted number of cells, the grid area, and the loaded volume to calculate the cell concentration per unit volume (e.g., cells/mL). manual cell count 9
  • 10. Advantages of using a hemocytometer: •Relatively inexpensive and readily available. •Provides detailed information on cell morphology and types. •Useful for low cell count samples. Disadvantages of using a hemocytometer: •Time-consuming and labor- intensive. •Requires skill and experience for accurate counting. •More prone to errors compared to automated methods. manual cell count 10
  • 11. Overall, hemocytometers remain valuable tools for manual cell counting in various applications, including blood analysis, cell culture experiments, and environmental monitoring. manual cell count 11
  • 12. Using a Hemocytometer in Four Simple Steps 1. Dilute Your Sample with Trypan blue Trypan blue is a stain that allows you to distinguish dead cells from living cells. When mixed with your cell sample, any dead cells will be stained blue by the dye, meaning that you can count only those cells that are living and viable. You can dilute your sample with trypan blue at any ratio, but a 1:1 ratio is the most common. Whatever dilution you use, make sure to note it down as you’ll need this for your final calculation. manual cell count 12
  • 13. 2. Loading the Hemocytometer Before you get started, ensure that both the hemocytometer and its coverslip are clean by removing any dust particles with lens paper. Coverslips used for mounting on hemocytometers are specially made to be thicker than conventional microscopy coverslips because they must be able to overcome the surface tension of a drop of liquid. Make sure you place the coverslip over the counting surface before loading the cell suspension. Then place the pipette tip with your sample into one of the V-shaped wells, and gently expel the sample. The area under the coverslip fills by capillary action. Enough liquid should be introduced so that the mirrored surface is just covered, usually around 10 µl, but don’t overfill the surface. You can load two samples on one hemocytometer, one into each of the two grids. manual cell count 13
  • 14. The loaded hemocytometer is then placed on the microscope stage and the counting grid is brought into focus at low power. Allow the sample to settle for a couple of minutes and avoid moving the coverslip as it might introduce air bubbles and make counting difficult. manual cell count 14
  • 15. . Counting Cells in a Hemocytometer The full grid on a hemocytometer contains nine squares, each of which is 1 mm2 The central counting area of the hemocytometer contains 25 large squares and each large square has 16 smaller squares. When counting cells that overlap an exterior line or ruling, count only those cells on the top or right-hand line of the large square to avoid counting cells twice. Suspensions should be dilute enough so that the cells or other particles do not overlap each other on the grid, and should be uniformly distributed. manual cell count 15
  • 16. To perform the count, determine the magnification needed to recognize the desired cell type and systematically count the cells in selected squares so that the total count is approximately 100 cells, a minimum number of cells needed for a statistically significant count. manual cell count 16
  • 17. For large cells, you can simply count the cells inside the four large corner squares and the middle square For a dense suspension of small cells, you may wish to count the cells in the four outer and middle squares of the central square or make a more dilute suspension. Remember if a cell overlaps a line, count it as “in” if it overlaps the top or right- hand line and “out” if it overlaps the bottom or left-hand line manual cell count 17
  • 18. The area of the middle and each corner square is 1 mm x 1 mm = 1 mm2. The depth of each square is 0.1 mm. Hence, the final volume of each square at that depth is 100 nl. manual cell count 18
  • 19. Calculating Cell Concentration You can calculate your cell concentration using the following formula: Total cells/ml = (Total cells counted x Dilution factor x 10,000 cells/ml)/ Number of squares counted So, for example, if you diluted your sample 1:1 with Trypan blue (dilution factor is 2 in this case), and you counted 325 cells in the four corner squares plus the central big square (number of squares counted is 5), then: Total cells/ml = (325 cells x 2 x 10,000 cells/ml)/ 5 = 130 x 104 cells/ml manual cell count 19
  • 20. If you want to know how many cells you have in your original sample, just multiply the cell concentration by the total sample volume. For example, if your original sample volume is 5 ml, then: Total cells in sample = 130 x 104 cells/ml x 5 ml = 650 x 104 cells manual cell count 20