SlideShare a Scribd company logo
Metro count mc5810_loop_classifier
The MetroCount 5810 is a length-based vehicle classifier, employing MetroCount's proven time-stamping
            technology for maximum data flexibility and value. The MC5810 utilises a pair of inductive loops per lane,
            producing highly accurate vehicle volume, speed and length.
            The raw data produced by the MC5810 is fully compatible with MetroCount Traffic Executive's complete range of
            classification reports. At the core of the data analysis are the time-stamped individual vehicles common to all
            MetroCount's vehicle classifiers. Piezo, tube and loop data can be mixed and matched, to take advantage of each
            technology's strengths.




            The MetroCount 5810's modular design ensures long-term reliability. The MC5810 Roadside Unit contains
            high-speed, transient suppression components, protecting against local electrical disturbances. The MC5800 Series
            Breakout Board provides a robust link between the loop feeder cables and the MC5810, with integrated cable
            strain-relief, and additional levels of electrical protection.




©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier                                                                 1
The MC5810 uses dedicated, ultra-low power oscillators per loop, providing up to six months stand-alone battery life
            in semi-permanent applications, and minimal external power requirements for permanent sites. For solar-powered
            sites, panels can be small and unobtrusive.
            The MC5810 is continuously self-tuning, requiring no user adjustment of thresholds or sensitivity. MetroCount
            Traffic Executive's unique software diagnostics tools provide visual assurance of correct site operation and data
            quality, and assist in trouble-shooting faults.




            Remote site monitoring and data access is available via MetroCount's Remote Access Module and FieldPod
            subscription services.




                       Storage Capacity             up to 250,000 vehicles per lane
                      Number of Lanes               2
                     Power Requirements             6V internal alkaline battery, with optional 6-18V external supply
                     Internal Battery Life          180 days continuous use, or 5 years as backup for external supply
                     Optimum Loop Size              2m x 2m
                   Optimum Loop Spacing             5m
                Operating Temperature Range         -10 to 60°C, 14 to 140°F
                   Loop Inductance Range            50 - 500µH (150µH optimum)
                    Loop Oscillator Range           45 - 65kHz
                     Power Consumption              <20mW
                         Data Storage               Flash memory, with up to 10 years retention




©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier                                                                 2
The MC5810 uses loops of wire, embedded in the road, to detect vehicles. A small, alternating current is injected
            into each loop, creating a magnetic field. When a vehicle passes over the loop, a portion of the magnetic field's
            energy couples to the conductive parts of the vehicle. The Roadside Unit detects this change and generates a
            time-stamp to indicate the loop is triggered. Another time-stamp is generated when the vehicle leaves the loop.




            MetroCount Traffic Executive partitions the time-stamps from a pair of loops into vehicles. The calculated speed of
            vehicles is very accurate, given the fixed distance between the two loops, and that two identical loops will trigger at
            the same point. The metallic length of the vehicle is then calculated from the speed, and the time the loops were
            triggered.
            Vehicles can be classified based on their calculated length. The distribution of vehicle lengths can typically be
            divided into four or five bins, with relatively little overlap. Length-based classification schemes are available for
            most regions, and new schemes can be easily created and applied to existing data.




©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier                                                                       3
MetroCount Traffic Executive provides the same intuitive setup interface for the MC5810, common to all
            MetroCount's Roadside Units. A setup operation is all that is required to start the unit logging.




            The important setup fields for the MC5810 are the loop spacing and effective length. The loop spacing is the distance
            from the leading edge of the first loop to the leading edge of the second loop, which is used to calculate the speed of
            vehicles. The length of one of the loops is used in calculating the length of vehicles.




            MTE's        mode provides confirmation that the Roadside Unit is successfully logging data by showing loop trigger
            events as vehicles pass the site.




©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier                                                                  4
The main design criteria for the MC5810's Breakout Board is reliability. All loop feeder cables terminate into robust
            screw terminals that can be easily inspected. Multiple tie-down points are provided for cable ties, to ensure adequate
            strain-relief.
            The Breakout Board's commoning block provides a convenient grounding point, crucial to the entire system's
            electrical protection. Each pair of inputs has a gas arrestor tube to suppress transient voltages, and every input
            contains a telecommunications-grade fuse for over-current protection. The MC5810's modular design means, in the
            event of a failure, individual components can be easily replaced.
            The MC5810's Breakout Board also provides flexible mounting options, including DIN rail mounts and convenient
            panel-mounting points.




            MetroCount Traffic Executive's unique                tool provides crucial feedback about complete site operation,
            from the Roadside Unit through to the loop sensors. Loop properties such as inductance, operating frequency and
            peak percentage deviation for the last vehicle, are automatically updated for the currently selected loop. An
            approximate Q-factor will also be calculated if the resistance of the loop is known.




©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier                                                                  5
If any fault condition exists, such as the loop connection being open or shorted, or any of the loop properties are
            outside reasonable operating values, these conditions can be immediately identified, without the need for additional
            test equipment.




            The LoopScope also has a real-time rolling view of loop deviation caused by passing vehicles. The chart shows the
            relative drop in inductance as a vehicle passes the loop, as well as the trigger levels used to register a count. This
            gives a clear indication of how reliably differing types of vehicles are triggering the Roadside Unit.




            The                is an extremely useful tool for testing the correct installation and reliability of all loop connections,
            such as screw terminals and crimp terminals. The            lights indicate whether each loop is operating correctly
            (green), or has a fault condition such as an open or short (red). There is also the option to play a tone if a fault
            condition is detected.




            By gently shaking cables and connections, any intermittent or faulty connections can be identified. The      lights
            indicate if any fault has occurred since the    button was pushed, highlighting even the shortest break or short in
            the connection.




©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier                                                                        6
Copyright© 1991, 2012 Microcom Pty Ltd. All rights reserved. MetroCount, Traffic Executive, MCSetup, MCSetLite, MCReport,
MCTools, Microcom and Microcom Pty Ltd, and the MetroCount and Microcom Pty Ltd logo, are trademarks of Microcom Pty
Ltd. All other trademarks are the property of their respective owners. Other Microcom intellectual property including Patents and
designs may be protected by international law. The furnishing of this software, the accompanying product or any related
documentation or materials does not give you any license to this intellectual property.

More Related Content

PDF
Metro count mc5805_loop_counter
PDF
Handbook on maintenance of digital axle counter
PDF
Riello Multi Sentry Uninterruptible Power Supplies Suppliers,London UK
PDF
IRJET- Smart Digi Train
PDF
04762477
PDF
Design and implementation of autonomous maneuvering robotic vehicle using glo...
PDF
LINE FOLLOWER ROBOT | J4RV4I1010
PDF
Control of Four Switch Three Phase Inverter Fed Induction Motor Drives Based ...
Metro count mc5805_loop_counter
Handbook on maintenance of digital axle counter
Riello Multi Sentry Uninterruptible Power Supplies Suppliers,London UK
IRJET- Smart Digi Train
04762477
Design and implementation of autonomous maneuvering robotic vehicle using glo...
LINE FOLLOWER ROBOT | J4RV4I1010
Control of Four Switch Three Phase Inverter Fed Induction Motor Drives Based ...

What's hot (20)

PPT
PDF
Internship Report - Rizwan Asif
PDF
Simulation Design of DC Motor Control System Based on MC9S12D64 MCU
PDF
PDF
IRJET- Automatic Vehicle Speed Controller System in Restricted Areas
PDF
Traning report _central_electronic_limited_ (1)
PDF
Autonomous Tank Report - May 8 2015
PPTX
Railway summer training report electrical engineering
PDF
IRJET- Smart Traffic Barricade System
PPT
Railnet
PDF
Motor circuit breakers mmp t series dienhathe.org
PDF
Summer Internship Report -By Rahul Mehra
PDF
IRJET- Smart Digi Train
DOC
PROJECT REPORT anti theft and auto braking car
PDF
TRAINING REPORT
PDF
Speed Control of FSTP Inverter Fed Induction Motor Drive with a Neural Networ...
DOCX
Autonomous Terrain Mapping Using COTS Hardware
PDF
Gsmdocument 131119095413-phpapp01
PDF
IRJET- Comparative Analysis of High Speed SRAM Cell for 90nm CMOS Technology
PDF
Speed Tracking of Field Oriented Control Permanent Magnet Synchronous Motor U...
Internship Report - Rizwan Asif
Simulation Design of DC Motor Control System Based on MC9S12D64 MCU
IRJET- Automatic Vehicle Speed Controller System in Restricted Areas
Traning report _central_electronic_limited_ (1)
Autonomous Tank Report - May 8 2015
Railway summer training report electrical engineering
IRJET- Smart Traffic Barricade System
Railnet
Motor circuit breakers mmp t series dienhathe.org
Summer Internship Report -By Rahul Mehra
IRJET- Smart Digi Train
PROJECT REPORT anti theft and auto braking car
TRAINING REPORT
Speed Control of FSTP Inverter Fed Induction Motor Drive with a Neural Networ...
Autonomous Terrain Mapping Using COTS Hardware
Gsmdocument 131119095413-phpapp01
IRJET- Comparative Analysis of High Speed SRAM Cell for 90nm CMOS Technology
Speed Tracking of Field Oriented Control Permanent Magnet Synchronous Motor U...
Ad

Viewers also liked (7)

PDF
Other languages fra
PDF
Other languages ita
PDF
Mc5600 rsu operator guide
PDF
Speed bin report by vehicle class
PPSX
Mc5810 install
PDF
Bp gfor sttc_oct_26_2011
PDF
Metro count mc5740_piezo-test_rsu
Other languages fra
Other languages ita
Mc5600 rsu operator guide
Speed bin report by vehicle class
Mc5810 install
Bp gfor sttc_oct_26_2011
Metro count mc5740_piezo-test_rsu
Ad

Similar to Metro count mc5810_loop_classifier (20)

PDF
Mc5710
PDF
Zx range datasheet_0611
PDF
Ff25965968
PDF
Bf24371374
PDF
Manuale 3 lw8108en
PDF
iRTU F: The RTU with Fault Detection
PDF
A Generalized Multistage Economic Planning Model for Distribution System Cont...
PDF
Designing Automatic Meter Reading System Using Open Source Hardware and Softw...
PPTX
cable fault.pptx
PDF
Design & Implementation Of Fault Identification In Underground Cables Using IOT
PPTX
under grund fault ppt (1).pptx
PDF
Gsm or x10 based scada system for industrial
PDF
Gsm or x10 based scada system for industrial automation
PDF
SICAM FPI - Fault Passage Indicator
PDF
PPTX
fault detection of transformer using GSM,,,,by YASASWINI.KAGITHALA
PPTX
KAGITHALA YASASWINI
PDF
ENERGY MANAGEMENT USING ANDROID APPLICATION
PPTX
Nairobi Water
PDF
Iaetsd automated bus monitoring and ticketing system
Mc5710
Zx range datasheet_0611
Ff25965968
Bf24371374
Manuale 3 lw8108en
iRTU F: The RTU with Fault Detection
A Generalized Multistage Economic Planning Model for Distribution System Cont...
Designing Automatic Meter Reading System Using Open Source Hardware and Softw...
cable fault.pptx
Design & Implementation Of Fault Identification In Underground Cables Using IOT
under grund fault ppt (1).pptx
Gsm or x10 based scada system for industrial
Gsm or x10 based scada system for industrial automation
SICAM FPI - Fault Passage Indicator
fault detection of transformer using GSM,,,,by YASASWINI.KAGITHALA
KAGITHALA YASASWINI
ENERGY MANAGEMENT USING ANDROID APPLICATION
Nairobi Water
Iaetsd automated bus monitoring and ticketing system

Recently uploaded (20)

PDF
Electronic commerce courselecture one. Pdf
PDF
Per capita expenditure prediction using model stacking based on satellite ima...
PDF
Unlocking AI with Model Context Protocol (MCP)
DOCX
The AUB Centre for AI in Media Proposal.docx
PDF
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
PDF
Chapter 3 Spatial Domain Image Processing.pdf
PDF
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
PDF
Empathic Computing: Creating Shared Understanding
PDF
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
PPTX
A Presentation on Artificial Intelligence
PDF
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
PDF
Advanced methodologies resolving dimensionality complications for autism neur...
PDF
Encapsulation_ Review paper, used for researhc scholars
PDF
Assigned Numbers - 2025 - Bluetooth® Document
PDF
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
PPTX
KOM of Painting work and Equipment Insulation REV00 update 25-dec.pptx
PDF
Network Security Unit 5.pdf for BCA BBA.
PPTX
Digital-Transformation-Roadmap-for-Companies.pptx
PDF
Building Integrated photovoltaic BIPV_UPV.pdf
PDF
A comparative analysis of optical character recognition models for extracting...
Electronic commerce courselecture one. Pdf
Per capita expenditure prediction using model stacking based on satellite ima...
Unlocking AI with Model Context Protocol (MCP)
The AUB Centre for AI in Media Proposal.docx
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
Chapter 3 Spatial Domain Image Processing.pdf
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
Empathic Computing: Creating Shared Understanding
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
A Presentation on Artificial Intelligence
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
Advanced methodologies resolving dimensionality complications for autism neur...
Encapsulation_ Review paper, used for researhc scholars
Assigned Numbers - 2025 - Bluetooth® Document
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
KOM of Painting work and Equipment Insulation REV00 update 25-dec.pptx
Network Security Unit 5.pdf for BCA BBA.
Digital-Transformation-Roadmap-for-Companies.pptx
Building Integrated photovoltaic BIPV_UPV.pdf
A comparative analysis of optical character recognition models for extracting...

Metro count mc5810_loop_classifier

  • 2. The MetroCount 5810 is a length-based vehicle classifier, employing MetroCount's proven time-stamping technology for maximum data flexibility and value. The MC5810 utilises a pair of inductive loops per lane, producing highly accurate vehicle volume, speed and length. The raw data produced by the MC5810 is fully compatible with MetroCount Traffic Executive's complete range of classification reports. At the core of the data analysis are the time-stamped individual vehicles common to all MetroCount's vehicle classifiers. Piezo, tube and loop data can be mixed and matched, to take advantage of each technology's strengths. The MetroCount 5810's modular design ensures long-term reliability. The MC5810 Roadside Unit contains high-speed, transient suppression components, protecting against local electrical disturbances. The MC5800 Series Breakout Board provides a robust link between the loop feeder cables and the MC5810, with integrated cable strain-relief, and additional levels of electrical protection. ©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier 1
  • 3. The MC5810 uses dedicated, ultra-low power oscillators per loop, providing up to six months stand-alone battery life in semi-permanent applications, and minimal external power requirements for permanent sites. For solar-powered sites, panels can be small and unobtrusive. The MC5810 is continuously self-tuning, requiring no user adjustment of thresholds or sensitivity. MetroCount Traffic Executive's unique software diagnostics tools provide visual assurance of correct site operation and data quality, and assist in trouble-shooting faults. Remote site monitoring and data access is available via MetroCount's Remote Access Module and FieldPod subscription services. Storage Capacity up to 250,000 vehicles per lane Number of Lanes 2 Power Requirements 6V internal alkaline battery, with optional 6-18V external supply Internal Battery Life 180 days continuous use, or 5 years as backup for external supply Optimum Loop Size 2m x 2m Optimum Loop Spacing 5m Operating Temperature Range -10 to 60°C, 14 to 140°F Loop Inductance Range 50 - 500µH (150µH optimum) Loop Oscillator Range 45 - 65kHz Power Consumption <20mW Data Storage Flash memory, with up to 10 years retention ©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier 2
  • 4. The MC5810 uses loops of wire, embedded in the road, to detect vehicles. A small, alternating current is injected into each loop, creating a magnetic field. When a vehicle passes over the loop, a portion of the magnetic field's energy couples to the conductive parts of the vehicle. The Roadside Unit detects this change and generates a time-stamp to indicate the loop is triggered. Another time-stamp is generated when the vehicle leaves the loop. MetroCount Traffic Executive partitions the time-stamps from a pair of loops into vehicles. The calculated speed of vehicles is very accurate, given the fixed distance between the two loops, and that two identical loops will trigger at the same point. The metallic length of the vehicle is then calculated from the speed, and the time the loops were triggered. Vehicles can be classified based on their calculated length. The distribution of vehicle lengths can typically be divided into four or five bins, with relatively little overlap. Length-based classification schemes are available for most regions, and new schemes can be easily created and applied to existing data. ©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier 3
  • 5. MetroCount Traffic Executive provides the same intuitive setup interface for the MC5810, common to all MetroCount's Roadside Units. A setup operation is all that is required to start the unit logging. The important setup fields for the MC5810 are the loop spacing and effective length. The loop spacing is the distance from the leading edge of the first loop to the leading edge of the second loop, which is used to calculate the speed of vehicles. The length of one of the loops is used in calculating the length of vehicles. MTE's mode provides confirmation that the Roadside Unit is successfully logging data by showing loop trigger events as vehicles pass the site. ©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier 4
  • 6. The main design criteria for the MC5810's Breakout Board is reliability. All loop feeder cables terminate into robust screw terminals that can be easily inspected. Multiple tie-down points are provided for cable ties, to ensure adequate strain-relief. The Breakout Board's commoning block provides a convenient grounding point, crucial to the entire system's electrical protection. Each pair of inputs has a gas arrestor tube to suppress transient voltages, and every input contains a telecommunications-grade fuse for over-current protection. The MC5810's modular design means, in the event of a failure, individual components can be easily replaced. The MC5810's Breakout Board also provides flexible mounting options, including DIN rail mounts and convenient panel-mounting points. MetroCount Traffic Executive's unique tool provides crucial feedback about complete site operation, from the Roadside Unit through to the loop sensors. Loop properties such as inductance, operating frequency and peak percentage deviation for the last vehicle, are automatically updated for the currently selected loop. An approximate Q-factor will also be calculated if the resistance of the loop is known. ©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier 5
  • 7. If any fault condition exists, such as the loop connection being open or shorted, or any of the loop properties are outside reasonable operating values, these conditions can be immediately identified, without the need for additional test equipment. The LoopScope also has a real-time rolling view of loop deviation caused by passing vehicles. The chart shows the relative drop in inductance as a vehicle passes the loop, as well as the trigger levels used to register a count. This gives a clear indication of how reliably differing types of vehicles are triggering the Roadside Unit. The is an extremely useful tool for testing the correct installation and reliability of all loop connections, such as screw terminals and crimp terminals. The lights indicate whether each loop is operating correctly (green), or has a fault condition such as an open or short (red). There is also the option to play a tone if a fault condition is detected. By gently shaking cables and connections, any intermittent or faulty connections can be identified. The lights indicate if any fault has occurred since the button was pushed, highlighting even the shortest break or short in the connection. ©2012 MetroCount® - MC5800 Series RSUs - MC5810 Loop Classifier 6
  • 8. Copyright© 1991, 2012 Microcom Pty Ltd. All rights reserved. MetroCount, Traffic Executive, MCSetup, MCSetLite, MCReport, MCTools, Microcom and Microcom Pty Ltd, and the MetroCount and Microcom Pty Ltd logo, are trademarks of Microcom Pty Ltd. All other trademarks are the property of their respective owners. Other Microcom intellectual property including Patents and designs may be protected by international law. The furnishing of this software, the accompanying product or any related documentation or materials does not give you any license to this intellectual property.