SlideShare a Scribd company logo
Super Max+ series works on the principle on
the principle of 3-level IGBT technology which
maximizes the e ciency and the 3-stage
extendable charging design optimizes the
battery performance. This series is generator
compatible and parallel operation up to 3 units
is possible. The communication over SNMP,
USM and RS-232 is available
20KVA / 30KVA / 40KVA
3 PHASE IN ~ 3 PHASE OUT
• Unity Output Power Factor
• DSP Technology with IGBT based PFC & Inverter
section
• 3-Level IGBT Inverter design Maximizes Efficiency
• Active Power Factor Correction in all 3-Phases
• 50Hz/60Hz Frequency Converter mode
• ECO mode operation for Energy Saving (ECO)
• Backfeed Energy Absorption Box (OPTIONAL), if Need
to Operate Motor type Loads on UPS
• Generator Compatible
• USB+RS-232 Multiple Communications available,
SNMP (Optional)
• 3-Stage extendable Charging Design for Optimized
Battery Performance
• Adjustable Battery Numbers (from 32 to 40-Batteries
in pairs of 2)
• Built-In Maintenance Bypass & Static Bypass
Switches
• Parallel Operation upto 3 Units (Optional). (with
Common Battery Bank)
• Isolation Transformer (Optional)
• Smart 4.3" Touch Panel LCD Display
for Real-time information for
measurement & adjustment of
maximum parameters
• EMI Protection (C3-Level) available
at Input & Output
• Surge Protection available at Input
across R/S/T - N & R/S/T/N - G
FEATURES:
BENEFITS:
*When
output
voltage
is
set
as
3
x
360VAC,
the
output
power
of
the
unit
will
be
de-rated
to
90%.
*Product
specifications
are
subject
to
change
without
prior
notice.
30KVA/30KW
INPUT
O UTPUT
NUMBER OF BATTERIES
CHARGE CURRENT (Max.)
CHARGING VOLTAGE
OPERATING HUMIDITY / TEMP.
BATTERY
PHYSICAL
ENVIRONMENT
M ANAGEM ENT
BATTERY TYPE
DIMENSIONS PRODUCT(LxWxH)
NET WEIGHT PRODUCT(KGS.)
NOISE LEVEL
SMART RS-232 OR USB
OPTIONAL SNMP
CAPACITY
3 x 400 VAC (3Ph+N)
46~54 Hz or 56~64Hz
≧ 0.99 @ 100% load
<4% @ 100% R-Load, <5% @ 100% RCD Load at 230VAC
NOMINAL VOLTAGE
FREQUENCY RANGE
NOMINAL VOLTAGE
FREQUENCY RANGE
CURRENT CREST RATIO
HARMONIC DISTORTION
POWER FACTOR
INPUT CURRENT HARMONIC
DISTORTION THD(i)
3 x 360*/380/400/415 VAC (3Ph+N)
46~54Hz or 56~64Hz (Synchronized Range)
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz (Battery Mode)
AC Mode: 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately
Battery Mode: 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately
OVERLOAD CAPABILITY
AC MODE TO BATTERY MODE
INVERTER TO BYPASS
WAVEFORM(BATTERY MODE)
EFFICIENCY
TRANSFER TIME
3:1 (Max)
≦ 2 % THD(LinearLoad); ≦ 5% THD (Non-Linear Load)
Zero
Zero
Pure Sine Wave
AC Mode: 95.5% / ECO Mode: 98.5% / BATTERY Mode: 94.5%
Default:32 Nos. Adjustable: 40 Nos.
(NOTE: Double Bank in Series of (16~20) + (16~20) Battery with Centre-Tapped Configuration)
12A Maximum, Adjustable = 1A/2A/3A/4A/5A/6A/7A/8A/9A/10A/11A/12A, Factory Setting = 4A
815x300x1000( in mm)
60 Kgs.
+/-13.65V*N (N = 16~20)
95% and Non-Condersing / 0-40°C
Less than 65dB @ 1 Meter
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC
Power Management from SNMP Manager and Web Browser
VRLA / LEAD-ACID Type
DEFAULT: ± 192VDC (32-Battery), ADJUSTABLE: ± 240VDC (40-Battery)
DC VOLTAGE
3 PHASE IN ~ 3 PHASE OUT
PHASE
190-520 VAC (3-Phase) @ 50% Load / 305-478 VAC (3-Phase) @ 100% Load
ACCEPTABLE VOLTAGE RANGE
6% @ 50% R-Load,  12% @ 50% RCD Load at 230VAC
AC VOLTAGE REGULATION ±1%(Battery Mode)
40KVA/40KW
INDICATORS
LCD PANEL UPS Status, Load Percentage, Load Amperes on each Phase, Output VA  Output Wattage per Phase,
Battery level (Charging Ampere  Discharging Ampere), Input/Output Voltage (Phase to Neutral 
Phase to Phase Voltage information), Input/Output Frequency, Input Line Current per Phase, Input VA 
Input Wattage Per Phase, Temperature information and Data Log Events.
61 Kgs.
INGRESS PROTECTION (IP Rating) IP-20
43 Kgs.
630x250x750( in mm)
20KVA/20KW
SUPER MAX+ 30KVA  40KVA HIGH FREQUENCY ONLINE UPS
M O D EL
TECHNICAL SPECIFICATIONS
60KVA / 80KVA / 100KVA / 120KVA
3 PHASE IN ~ 3 PHASE OUT
• True double-conversion
• DSP technology guarantees high performance
• Output power factor 1
• Active power factor correction in all phases at Input
• 50Hz/60Hz frequency converter mode
• ECO mode operation for energy saving (ECO)
• Emergency power off function (EPO)
• Generator compatible
• SNMP+USB+RS-232 multiple communications
• 3-stage extendable charging design for optimized
battery performance
• Adjustable battery numbers 32-40 battery
• Maintenance bypass available
• Parallel can be done with either individual battery
bank on each UPS, or with Common Battery Bank.
• Parallel can be done with either individual battery
bank on each UPS, or with Common Battery Bank
(But Parallel  Share current cables are Optional,
need to Order separately for Parallel)
• Optional External backfeed Absorb box, for
Regenerative type loads like ElevatorsLifts, some
CNC Machines etc. The indication of such type of
loads on UPS is, it will trip its output detecting UPS
internal bus voltage high errorfault.
• Smart 5 touch Panel LCD display in
6080KVA  7 in 100120 KVA for
Real-time information for
measurement  adjustment of
maximum parameters.
• EMI Protection (C3-Level) available
at Input  Output.
• ± 6KVA Surge Protection available at
Input across R/S/T - N  R/S/T/N - G
• Swappable Power Modules in
100KVA  120KVA, with 2 x 50KW
Power modules in 100KVA  2x
60KW Power Modules in 120KVA,
with Common Control Boards, for
ease of service maintenance.
• Dual-Input design for ease of
connecting 2 UPS in hot-standby or
to provide other secondary source
on the bypass input.
FEATURES:
BENEFITS:
100120KVA
(Transformer-Less
Design)
6080KVA
(Transformer-Less
Design)
*When
output
voltage
is
set
as
3
x
360VAC,
the
output
power
of
the
unit
will
be
de-rated
to
90%.
*Product
specifications
are
subject
to
change
without
further
notice.
TECHNICAL SPECIFICATIONS
80KL
80KVA/80KW
100KL
100KVA/100KW
INPUT
O UTPUT
NUMBERS
CHARGING CURRENT (MAX.)
CHARGING VOLTAGE
OPERATION TEMPERTURE
BATTERY
PHYSICAL
ENVIRONMENT
M ANAGEM ENT
BATTERY TYPE
DIMENSION, D X W X H (MM)
NET WEIGHT (KGS)
OPERATION HUMIDITY
SMART RS-232/USB
POTHENTIAL-FREE CONTACT
(DRY-CONTACT) PORT
CAPACITY
3 x 400 VAC (3Ph+N)
46~54 Hz or 56~64Hz
≧ 0.99 @ 100% load
NOMINAL VOLTAGE
OUTPUT VOLTAGE
FREQUENCY RANGE
(SYNCHRONIZED RANGE)
FREQUENCY RANGE (BATT. MODE)
CURRENT CREST RATIO
FREQUENCY RANGE
POWER FACTOR
3 x 360**/380/400/415 VAC (3Ph+N)
46~54Hz or 56~64Hz
≦ 2 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
HARMONIC DISTORTION (THDv)
AT OUTPUT
AC MODE
ECO MODE
EFFICIENCY (peak efficiency)
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
3:1 (max.)
95.5%
98.5%
94.5%
32~40 pcs (Adjustable)
+/-13.65V*N (N = 16~20)
0-40°C
95% and non-condersing
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and MAC
8-Input  6-Output Dry-Contact port available
SMF (VRLA) / LEAD-ACID BATTERIES
PHASE
CAPACITY
190-520 VAC (3-phase) @ 50% load
305-478 VAC (3-phase) @ 100% load
VOLTAGE RANGE
AC VOLTAGE REGULATION (BATT. MODE) ± 1%
INDICATORS
LCD PANEL
(5-INCH TOUCH SCREEN LCD
IN 60-80K  7-INCH IN 100-120KVA)
UPS status, Load percentages  amperes on each phase at output, Output VA  Wattage in each phase,
Battery level (Charging ampere  discharging ampere), Input/Output voltage (Phase to Neutral  phase
to phase information), Input / output Frequency, Input Line Current per phase, Input VA/ Wattage/ PF per phase,
Temperature information, Data Log Events (max 500-events) and Fault conditions
NOISE LEVEL Less than 70dBA @ 1-meter
74 113 250
60KL
60KVA/60KW
SUPERMAX+ 3P/3P 60K~120KVA ONLINE UPS
TRANSFER
TIME
OVERLOAD
AC MODE TO
BATTERY MODE
AC MODE
INVERTER TO BYPASS
BATTERY MODE
Zero
100-110% for 60 min, 110-125% for 10 min, 126%-150% for 1 min, 150% for 400ms
Zero
100-110% for 60 min, 110-125% for 10 min, 126%-150% for 1 min, 150% for 400ms
WAVEFORM (BATT. MODE) PURE SINE WAVE
PARALLEL CAPACITY up to 4 units in parallel with Either Common battery bank or Separate battery bank
BATTERY MODE
LOW BATTERY
OVERLOAD
FAULT
ALARM
BATTERY MODE
Sounding every second
Continuously sounding
Sounding every 4 seconds
Sounding twice every second
120KL
120KVA/120KW
3-Phase in / 3-Phase out
 4% at full Linear Load
HARMONICS DISTORTION (THDi)
2A~32A (Adjustable) 2A - 24A (Adjustable)
2A~18A (Adjustable) 2A - 36A (Adjustable)
815 x 300 x 1000 790 x 360 x 1010 974 x 600 x 1600
Less then 75dBA @ 1-meter
OPTIONAL SNMP Power management from SNMP manager and web browser
M O D EL
With
Inbuilt Isolation
Transformer
With
External Optional
Isolation
Transformer
60KVA / 80KVA / 100KVA / 120KVA
3 PHASE IN ~ 3 PHASE OUT
• Smart 5 touch Panel LCD display in
6080KVA  7 in 100120 KVA for
Real-time information for
measurement  adjustment of
maximum parameters.
• EMI Protection (C3-Level) available
at Input  Output.
• ± 6KVA Surge Protection available at
Input across R/S/T - N  R/S/T/N - G
• Swappable Power Modules in
100KVA  120KVA, with 2 x 50KW
Power modules in 100KVA  2x
60KW Power Modules in 120KVA,
with Common Control Boards, for
ease of service maintenance.
• Dual-Input design for ease of
connecting 2 UPS in hot-standby or
to provide other secondary source
on the bypass input.
BENEFITS:
100120KVA
6080KVA
TECHNICAL SPECIFICATIONS
INPUT
O UTPUT
NUMBERS
CHARGING CURRENT (MAX.)
CHARGING VOLTAGE
OPERATION TEMPERTURE
BATTERY
PHYSICAL
ENVIRONMENT
MANAGEMENT
BATTERY TYPE
DIMENSION, D X W X H (MM)
NET WEIGHT (KGS)
OPERATION HUMIDITY
SMART RS-232/USB
OPTIONAL SNMP
3 x 400 VAC (3Ph+N)
46~54 Hz or 56~64Hz
≧ 0.99 @ 100% load
NOMINAL VOLTAGE
OUTPUT VOLTAGE
FREQUENCY RANGE
(SYNCHRONIZED RANGE)
FREQUENCY RANGE (BATT. MODE)
CURRENT CREST RATIO
FREQUENCY RANGE
POWER FACTOR
3 x 360**/380/400/415 VAC (3Ph+N)
46~54Hz or 56~64Hz
≦ 2 % THD (Linear Load)
≦ 10 % THD (Non-linear Load)
≦ 2 % THD (Linear Load)
≦ 10 % THD (Non-linear Load)
HARMONIC DISTORTION
AC MODE
ECO MODE
EFFICIENCY
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
2.6:1 (max.) 3:1 (max.)
87.5% 87.5%
93.5% 93.5%
86.5% 86.5%
32~40 pcs (Adjustable)
+/-13.65V*N (N = 16~20)
0-40°C
95% and non-condersing
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and MAC
Power management from SNMP manager and web browser
Depending on the capacity of external batteries
CAPACITY
190-520 VAC (3-phase) @ 50% load
305-478 VAC (3-phase) @ 100% load
VOLTAGE RANGE
AC VOLTAGE REGULATION (BATT. MODE) ± 1%
INDICATORS
LCD PANEL
(5-INCH TOUCH SCREEN LCD)
UPS status, Load percentages  amperes on each phase at output, Output VA  Wattage in each phase,
Battery level (Charging ampere  discharging ampere), Input/Output voltage (Phase to Neutral  phase
to phase information), Input / output Frequency, Input Line Current per phase, Input VA/ Wattage/ PF per phase,
Temperature information, Data Log Events (max 500-events) and Fault conditions
NOISE LEVEL Less than 75dB @ 1 Meter
440 475
60KVA/60KW
TRANSFER
TIME
OVERLOAD
AC MODE TO
BATTERY MODE
AC MODE
INVERTER TO BYPASS
BATTERY MODE
Zero
100-110% for 60 min, 110-125% for 10 min, 126%-150% for 1 min, 150% for 400ms
Zero
100-110% for 60 min, 110-125% for 10 min, 126%-150% for 1 min, 150% for 400ms
WAVEFORM (BATT. MODE) PURE SINE WAVE
PARALLEL CAPACITY
BATTERY MODE
LOW BATTERY
OVERLOAD
FAULT
ALARM
BATTERY MODE
Sounding every second
Continuously sounding
Sounding every 4 seconds
Sounding twice every second
*When
output
voltage
is
set
as
3
x
360VAC,
the
output
power
of
the
unit
will
be
de-rated
to
90%.
*Product
specifications
are
subject
to
change
without
further
notice.
80KVA/80KW 100KVA/100KW
80KL
CAPACITY
PHASE
60KL
SUPERMAX+ 3P/3P 60K~120K ONLINE UPS WITH ISO TX AT OUTPUT
MODEL
100KL 120KL
120KVA/120KW
External Isolation Transformer Optional
SMF (VRLA) / LEAD-ACID BATTERIES
2A~32A (Adjustable) 2A - 24A (Adjustable)
2A~18A (Adjustable) 2A - 36A (Adjustable)
790 x 720 x 1060 974 x 600 x 1600
250
Less than 75dB @ 1 Meter
Isolation Trx Inbuilt
Isolation Trx Inbuilt
Max upto 4-Units, with either Individual battery bank OR Common battery bank
SUPER PERFORMANCE HIGH FREQUENCY ONLINE UPS
• True double-conversion
• DSP technology guarantees high performance
• Output power factor 1
• Active power factor correction in all phases at Input
• 50Hz/60Hz frequency converter mode
• ECO mode operation for energy saving (ECO)
• Emergency power off function (EPO)
• Generator compatible
• SNMP+USB+RS-232 multiple communications
• 3-stage extendable charging design for optimized
battery performance
• Adjustable battery numbers 32-40 battery
• Maintenance bypass available
• Parallel can be done with either individual battery
bank on each UPS, or with Common Battery Bank.
• Parallel can be done with either individual battery
bank on each UPS, or with Common Battery Bank
(But Parallel  Share current cables are Optional,
need to Order separately for Parallel)
• Optional External backfeed Absorb box, for
Regenerative type loads like ElevatorsLifts, some
CNC Machines etc. The indication of such type of
loads on UPS is, it will trip its output detecting UPS
internal bus voltage high errorfault.
FEATURES:

More Related Content

PDF
Bộ lưu điện ups gtec chính hãng Italia
PDF
Modular UPS 40 - 1.5 MVA.pdf
PDF
Commercial UPS - Raptor Power Systems
PDF
Baykee SR series solar inverter with AVR Function
PPS
Power ups hpm presentation-r2
PDF
Baykee SL series solar inverter Optional AVR Function
PPT
Power u ps hpm3300
PPT
Power u ps hpm3300 presentation-r1
Bộ lưu điện ups gtec chính hãng Italia
Modular UPS 40 - 1.5 MVA.pdf
Commercial UPS - Raptor Power Systems
Baykee SR series solar inverter with AVR Function
Power ups hpm presentation-r2
Baykee SL series solar inverter Optional AVR Function
Power u ps hpm3300
Power u ps hpm3300 presentation-r1

Similar to Microtek Inverter Battery: Your Go-To for Absolutely Zero Power Worries. (20)

PDF
RS Power Systems Profile
PPTX
Product: UPS: FirstLine P
PPT
Power u ps hip3300 presentation
PDF
Online UPS (ML11T) VESTA
PDF
Tower/Rack UPS
PDF
Aet series
PDF
Ecopowersupplies: Riello sentinel-pro-ups-datasheet
PPS
Power u ps hip3300 -500 kva
PDF
Apc surt 4
PPT
9900 Presentation
PDF
Online UPS,Battery, Solar Inverter Supplier
PDF
Delta products overview
PDF
Huawei ups product and solution 02 (20140318)
PDF
Ecopowersupplies: Riello Sentinel Dual High Power UPS
PDF
Mitsubishi 9900 presentation 7 1-08
PDF
PDF
PDF
Ecopowersupplies: Riello-Multi-Sentry-UPS
PPSX
New Spring Line Interactive UPS series presentaton ortechPS
PPTX
Product: UPS: UniStar V
RS Power Systems Profile
Product: UPS: FirstLine P
Power u ps hip3300 presentation
Online UPS (ML11T) VESTA
Tower/Rack UPS
Aet series
Ecopowersupplies: Riello sentinel-pro-ups-datasheet
Power u ps hip3300 -500 kva
Apc surt 4
9900 Presentation
Online UPS,Battery, Solar Inverter Supplier
Delta products overview
Huawei ups product and solution 02 (20140318)
Ecopowersupplies: Riello Sentinel Dual High Power UPS
Mitsubishi 9900 presentation 7 1-08
Ecopowersupplies: Riello-Multi-Sentry-UPS
New Spring Line Interactive UPS series presentaton ortechPS
Product: UPS: UniStar V
Ad

More from Microtek India (20)

PDF
Microtek's Line Interactive UPS: Smart Power for Seamless Performance
PDF
No More Power Worries: Choose Microtek's Inverter Battery, The Ultimate Power...
PDF
Microtek Solar Panels - Powering Homes Across India with Top-Tier Efficiency.pdf
PDF
Microtek Premium Intelligent UPS: The Best Home UPS Inverter for Uninterrupte...
PDF
Microtek Smart Hybrid Inverter User Manual - Your Home UPS with Smart Display...
PDF
Microtek's Next-Gen Inverter Battery: Featuring Revolutionary ADC Technology.
PDF
Microtek Solar Panels – A Smarter Way to Power Your Home with Clean Energy
PDF
Microtek – The Best Stabilizer for AC 2 Ton Units in Indian Homes
PDF
Microtek – The Best UPS for Home in India.
PDF
All-New Microtek Inverter Battery Series – Engineered for Excellence.
PDF
Heavy Duty Jumbo UPS from Microtek – Built for Big Power Needs.
PDF
Microtek Stabilizer for AC & Home – Trusted Power Protection for Your Applian...
PDF
Microtek Solar Panel for Home – The Smart Way to Save and Shine
PDF
Reliable Power with Microtek's Best Inverter Battery: Heavy Duty with ADC Tec...
PDF
Microtek Elite Inverter - The Best Inverter with In-Built Compatibility for U...
PDF
Microtek Luxe WiFi Inverter - The Best Inverter for Smart Homes.
PDF
Inverter Battery Technology: A Step-by-Step Explanation by Microtek
PDF
Microtek's Guide: How Solar Solutions Perform in Winter
PDF
Microtek's Guide: Why Inverter is a Must-Have for Your Home
PDF
How Inverters Work: A Visual Guide by Microtek
Microtek's Line Interactive UPS: Smart Power for Seamless Performance
No More Power Worries: Choose Microtek's Inverter Battery, The Ultimate Power...
Microtek Solar Panels - Powering Homes Across India with Top-Tier Efficiency.pdf
Microtek Premium Intelligent UPS: The Best Home UPS Inverter for Uninterrupte...
Microtek Smart Hybrid Inverter User Manual - Your Home UPS with Smart Display...
Microtek's Next-Gen Inverter Battery: Featuring Revolutionary ADC Technology.
Microtek Solar Panels – A Smarter Way to Power Your Home with Clean Energy
Microtek – The Best Stabilizer for AC 2 Ton Units in Indian Homes
Microtek – The Best UPS for Home in India.
All-New Microtek Inverter Battery Series – Engineered for Excellence.
Heavy Duty Jumbo UPS from Microtek – Built for Big Power Needs.
Microtek Stabilizer for AC & Home – Trusted Power Protection for Your Applian...
Microtek Solar Panel for Home – The Smart Way to Save and Shine
Reliable Power with Microtek's Best Inverter Battery: Heavy Duty with ADC Tec...
Microtek Elite Inverter - The Best Inverter with In-Built Compatibility for U...
Microtek Luxe WiFi Inverter - The Best Inverter for Smart Homes.
Inverter Battery Technology: A Step-by-Step Explanation by Microtek
Microtek's Guide: How Solar Solutions Perform in Winter
Microtek's Guide: Why Inverter is a Must-Have for Your Home
How Inverters Work: A Visual Guide by Microtek
Ad

Recently uploaded (20)

PPTX
New Microsoft PowerPoint Presentation - Copy.pptx
PPTX
Belch_12e_PPT_Ch18_Accessible_university.pptx
PDF
Deliverable file - Regulatory guideline analysis.pdf
PDF
DOC-20250806-WA0002._20250806_112011_0000.pdf
PPTX
ICG2025_ICG 6th steering committee 30-8-24.pptx
PDF
IFRS Notes in your pocket for study all the time
PDF
COST SHEET- Tender and Quotation unit 2.pdf
PPTX
CkgxkgxydkydyldylydlydyldlyddolydyoyyU2.pptx
PDF
kom-180-proposal-for-a-directive-amending-directive-2014-45-eu-and-directive-...
PDF
Ôn tập tiếng anh trong kinh doanh nâng cao
PDF
A Brief Introduction About Julia Allison
PDF
Elevate Cleaning Efficiency Using Tallfly Hair Remover Roller Factory Expertise
PPTX
Dragon_Fruit_Cultivation_in Nepal ppt.pptx
DOCX
Euro SEO Services 1st 3 General Updates.docx
PDF
Business model innovation report 2022.pdf
PPTX
Business Ethics - An introduction and its overview.pptx
PDF
MSPs in 10 Words - Created by US MSP Network
DOCX
unit 1 COST ACCOUNTING AND COST SHEET
PPT
Data mining for business intelligence ch04 sharda
PDF
Nidhal Samdaie CV - International Business Consultant
New Microsoft PowerPoint Presentation - Copy.pptx
Belch_12e_PPT_Ch18_Accessible_university.pptx
Deliverable file - Regulatory guideline analysis.pdf
DOC-20250806-WA0002._20250806_112011_0000.pdf
ICG2025_ICG 6th steering committee 30-8-24.pptx
IFRS Notes in your pocket for study all the time
COST SHEET- Tender and Quotation unit 2.pdf
CkgxkgxydkydyldylydlydyldlyddolydyoyyU2.pptx
kom-180-proposal-for-a-directive-amending-directive-2014-45-eu-and-directive-...
Ôn tập tiếng anh trong kinh doanh nâng cao
A Brief Introduction About Julia Allison
Elevate Cleaning Efficiency Using Tallfly Hair Remover Roller Factory Expertise
Dragon_Fruit_Cultivation_in Nepal ppt.pptx
Euro SEO Services 1st 3 General Updates.docx
Business model innovation report 2022.pdf
Business Ethics - An introduction and its overview.pptx
MSPs in 10 Words - Created by US MSP Network
unit 1 COST ACCOUNTING AND COST SHEET
Data mining for business intelligence ch04 sharda
Nidhal Samdaie CV - International Business Consultant

Microtek Inverter Battery: Your Go-To for Absolutely Zero Power Worries.

  • 1. Super Max+ series works on the principle on the principle of 3-level IGBT technology which maximizes the e ciency and the 3-stage extendable charging design optimizes the battery performance. This series is generator compatible and parallel operation up to 3 units is possible. The communication over SNMP, USM and RS-232 is available 20KVA / 30KVA / 40KVA 3 PHASE IN ~ 3 PHASE OUT • Unity Output Power Factor • DSP Technology with IGBT based PFC & Inverter section • 3-Level IGBT Inverter design Maximizes Efficiency • Active Power Factor Correction in all 3-Phases • 50Hz/60Hz Frequency Converter mode • ECO mode operation for Energy Saving (ECO) • Backfeed Energy Absorption Box (OPTIONAL), if Need to Operate Motor type Loads on UPS • Generator Compatible • USB+RS-232 Multiple Communications available, SNMP (Optional) • 3-Stage extendable Charging Design for Optimized Battery Performance • Adjustable Battery Numbers (from 32 to 40-Batteries in pairs of 2) • Built-In Maintenance Bypass & Static Bypass Switches • Parallel Operation upto 3 Units (Optional). (with Common Battery Bank) • Isolation Transformer (Optional) • Smart 4.3" Touch Panel LCD Display for Real-time information for measurement & adjustment of maximum parameters • EMI Protection (C3-Level) available at Input & Output • Surge Protection available at Input across R/S/T - N & R/S/T/N - G FEATURES: BENEFITS: *When output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%. *Product specifications are subject to change without prior notice. 30KVA/30KW INPUT O UTPUT NUMBER OF BATTERIES CHARGE CURRENT (Max.) CHARGING VOLTAGE OPERATING HUMIDITY / TEMP. BATTERY PHYSICAL ENVIRONMENT M ANAGEM ENT BATTERY TYPE DIMENSIONS PRODUCT(LxWxH) NET WEIGHT PRODUCT(KGS.) NOISE LEVEL SMART RS-232 OR USB OPTIONAL SNMP CAPACITY 3 x 400 VAC (3Ph+N) 46~54 Hz or 56~64Hz ≧ 0.99 @ 100% load <4% @ 100% R-Load, <5% @ 100% RCD Load at 230VAC NOMINAL VOLTAGE FREQUENCY RANGE NOMINAL VOLTAGE FREQUENCY RANGE CURRENT CREST RATIO HARMONIC DISTORTION POWER FACTOR INPUT CURRENT HARMONIC DISTORTION THD(i) 3 x 360*/380/400/415 VAC (3Ph+N) 46~54Hz or 56~64Hz (Synchronized Range) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz (Battery Mode) AC Mode: 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately Battery Mode: 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately OVERLOAD CAPABILITY AC MODE TO BATTERY MODE INVERTER TO BYPASS WAVEFORM(BATTERY MODE) EFFICIENCY TRANSFER TIME 3:1 (Max) ≦ 2 % THD(LinearLoad); ≦ 5% THD (Non-Linear Load) Zero Zero Pure Sine Wave AC Mode: 95.5% / ECO Mode: 98.5% / BATTERY Mode: 94.5% Default:32 Nos. Adjustable: 40 Nos. (NOTE: Double Bank in Series of (16~20) + (16~20) Battery with Centre-Tapped Configuration) 12A Maximum, Adjustable = 1A/2A/3A/4A/5A/6A/7A/8A/9A/10A/11A/12A, Factory Setting = 4A 815x300x1000( in mm) 60 Kgs. +/-13.65V*N (N = 16~20) 95% and Non-Condersing / 0-40°C Less than 65dB @ 1 Meter Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Power Management from SNMP Manager and Web Browser VRLA / LEAD-ACID Type DEFAULT: ± 192VDC (32-Battery), ADJUSTABLE: ± 240VDC (40-Battery) DC VOLTAGE 3 PHASE IN ~ 3 PHASE OUT PHASE 190-520 VAC (3-Phase) @ 50% Load / 305-478 VAC (3-Phase) @ 100% Load ACCEPTABLE VOLTAGE RANGE 6% @ 50% R-Load, 12% @ 50% RCD Load at 230VAC AC VOLTAGE REGULATION ±1%(Battery Mode) 40KVA/40KW INDICATORS LCD PANEL UPS Status, Load Percentage, Load Amperes on each Phase, Output VA Output Wattage per Phase, Battery level (Charging Ampere Discharging Ampere), Input/Output Voltage (Phase to Neutral Phase to Phase Voltage information), Input/Output Frequency, Input Line Current per Phase, Input VA Input Wattage Per Phase, Temperature information and Data Log Events. 61 Kgs. INGRESS PROTECTION (IP Rating) IP-20 43 Kgs. 630x250x750( in mm) 20KVA/20KW SUPER MAX+ 30KVA 40KVA HIGH FREQUENCY ONLINE UPS M O D EL TECHNICAL SPECIFICATIONS
  • 2. 60KVA / 80KVA / 100KVA / 120KVA 3 PHASE IN ~ 3 PHASE OUT • True double-conversion • DSP technology guarantees high performance • Output power factor 1 • Active power factor correction in all phases at Input • 50Hz/60Hz frequency converter mode • ECO mode operation for energy saving (ECO) • Emergency power off function (EPO) • Generator compatible • SNMP+USB+RS-232 multiple communications • 3-stage extendable charging design for optimized battery performance • Adjustable battery numbers 32-40 battery • Maintenance bypass available • Parallel can be done with either individual battery bank on each UPS, or with Common Battery Bank. • Parallel can be done with either individual battery bank on each UPS, or with Common Battery Bank (But Parallel Share current cables are Optional, need to Order separately for Parallel) • Optional External backfeed Absorb box, for Regenerative type loads like ElevatorsLifts, some CNC Machines etc. The indication of such type of loads on UPS is, it will trip its output detecting UPS internal bus voltage high errorfault. • Smart 5 touch Panel LCD display in 6080KVA 7 in 100120 KVA for Real-time information for measurement adjustment of maximum parameters. • EMI Protection (C3-Level) available at Input Output. • ± 6KVA Surge Protection available at Input across R/S/T - N R/S/T/N - G • Swappable Power Modules in 100KVA 120KVA, with 2 x 50KW Power modules in 100KVA 2x 60KW Power Modules in 120KVA, with Common Control Boards, for ease of service maintenance. • Dual-Input design for ease of connecting 2 UPS in hot-standby or to provide other secondary source on the bypass input. FEATURES: BENEFITS: 100120KVA (Transformer-Less Design) 6080KVA (Transformer-Less Design) *When output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%. *Product specifications are subject to change without further notice. TECHNICAL SPECIFICATIONS 80KL 80KVA/80KW 100KL 100KVA/100KW INPUT O UTPUT NUMBERS CHARGING CURRENT (MAX.) CHARGING VOLTAGE OPERATION TEMPERTURE BATTERY PHYSICAL ENVIRONMENT M ANAGEM ENT BATTERY TYPE DIMENSION, D X W X H (MM) NET WEIGHT (KGS) OPERATION HUMIDITY SMART RS-232/USB POTHENTIAL-FREE CONTACT (DRY-CONTACT) PORT CAPACITY 3 x 400 VAC (3Ph+N) 46~54 Hz or 56~64Hz ≧ 0.99 @ 100% load NOMINAL VOLTAGE OUTPUT VOLTAGE FREQUENCY RANGE (SYNCHRONIZED RANGE) FREQUENCY RANGE (BATT. MODE) CURRENT CREST RATIO FREQUENCY RANGE POWER FACTOR 3 x 360**/380/400/415 VAC (3Ph+N) 46~54Hz or 56~64Hz ≦ 2 % THD (Linear Load) ≦ 5 % THD (Non-linear Load) HARMONIC DISTORTION (THDv) AT OUTPUT AC MODE ECO MODE EFFICIENCY (peak efficiency) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 3:1 (max.) 95.5% 98.5% 94.5% 32~40 pcs (Adjustable) +/-13.65V*N (N = 16~20) 0-40°C 95% and non-condersing Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and MAC 8-Input 6-Output Dry-Contact port available SMF (VRLA) / LEAD-ACID BATTERIES PHASE CAPACITY 190-520 VAC (3-phase) @ 50% load 305-478 VAC (3-phase) @ 100% load VOLTAGE RANGE AC VOLTAGE REGULATION (BATT. MODE) ± 1% INDICATORS LCD PANEL (5-INCH TOUCH SCREEN LCD IN 60-80K 7-INCH IN 100-120KVA) UPS status, Load percentages amperes on each phase at output, Output VA Wattage in each phase, Battery level (Charging ampere discharging ampere), Input/Output voltage (Phase to Neutral phase to phase information), Input / output Frequency, Input Line Current per phase, Input VA/ Wattage/ PF per phase, Temperature information, Data Log Events (max 500-events) and Fault conditions NOISE LEVEL Less than 70dBA @ 1-meter 74 113 250 60KL 60KVA/60KW SUPERMAX+ 3P/3P 60K~120KVA ONLINE UPS TRANSFER TIME OVERLOAD AC MODE TO BATTERY MODE AC MODE INVERTER TO BYPASS BATTERY MODE Zero 100-110% for 60 min, 110-125% for 10 min, 126%-150% for 1 min, 150% for 400ms Zero 100-110% for 60 min, 110-125% for 10 min, 126%-150% for 1 min, 150% for 400ms WAVEFORM (BATT. MODE) PURE SINE WAVE PARALLEL CAPACITY up to 4 units in parallel with Either Common battery bank or Separate battery bank BATTERY MODE LOW BATTERY OVERLOAD FAULT ALARM BATTERY MODE Sounding every second Continuously sounding Sounding every 4 seconds Sounding twice every second 120KL 120KVA/120KW 3-Phase in / 3-Phase out 4% at full Linear Load HARMONICS DISTORTION (THDi) 2A~32A (Adjustable) 2A - 24A (Adjustable) 2A~18A (Adjustable) 2A - 36A (Adjustable) 815 x 300 x 1000 790 x 360 x 1010 974 x 600 x 1600 Less then 75dBA @ 1-meter OPTIONAL SNMP Power management from SNMP manager and web browser M O D EL
  • 3. With Inbuilt Isolation Transformer With External Optional Isolation Transformer 60KVA / 80KVA / 100KVA / 120KVA 3 PHASE IN ~ 3 PHASE OUT • Smart 5 touch Panel LCD display in 6080KVA 7 in 100120 KVA for Real-time information for measurement adjustment of maximum parameters. • EMI Protection (C3-Level) available at Input Output. • ± 6KVA Surge Protection available at Input across R/S/T - N R/S/T/N - G • Swappable Power Modules in 100KVA 120KVA, with 2 x 50KW Power modules in 100KVA 2x 60KW Power Modules in 120KVA, with Common Control Boards, for ease of service maintenance. • Dual-Input design for ease of connecting 2 UPS in hot-standby or to provide other secondary source on the bypass input. BENEFITS: 100120KVA 6080KVA TECHNICAL SPECIFICATIONS INPUT O UTPUT NUMBERS CHARGING CURRENT (MAX.) CHARGING VOLTAGE OPERATION TEMPERTURE BATTERY PHYSICAL ENVIRONMENT MANAGEMENT BATTERY TYPE DIMENSION, D X W X H (MM) NET WEIGHT (KGS) OPERATION HUMIDITY SMART RS-232/USB OPTIONAL SNMP 3 x 400 VAC (3Ph+N) 46~54 Hz or 56~64Hz ≧ 0.99 @ 100% load NOMINAL VOLTAGE OUTPUT VOLTAGE FREQUENCY RANGE (SYNCHRONIZED RANGE) FREQUENCY RANGE (BATT. MODE) CURRENT CREST RATIO FREQUENCY RANGE POWER FACTOR 3 x 360**/380/400/415 VAC (3Ph+N) 46~54Hz or 56~64Hz ≦ 2 % THD (Linear Load) ≦ 10 % THD (Non-linear Load) ≦ 2 % THD (Linear Load) ≦ 10 % THD (Non-linear Load) HARMONIC DISTORTION AC MODE ECO MODE EFFICIENCY 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 2.6:1 (max.) 3:1 (max.) 87.5% 87.5% 93.5% 93.5% 86.5% 86.5% 32~40 pcs (Adjustable) +/-13.65V*N (N = 16~20) 0-40°C 95% and non-condersing Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and MAC Power management from SNMP manager and web browser Depending on the capacity of external batteries CAPACITY 190-520 VAC (3-phase) @ 50% load 305-478 VAC (3-phase) @ 100% load VOLTAGE RANGE AC VOLTAGE REGULATION (BATT. MODE) ± 1% INDICATORS LCD PANEL (5-INCH TOUCH SCREEN LCD) UPS status, Load percentages amperes on each phase at output, Output VA Wattage in each phase, Battery level (Charging ampere discharging ampere), Input/Output voltage (Phase to Neutral phase to phase information), Input / output Frequency, Input Line Current per phase, Input VA/ Wattage/ PF per phase, Temperature information, Data Log Events (max 500-events) and Fault conditions NOISE LEVEL Less than 75dB @ 1 Meter 440 475 60KVA/60KW TRANSFER TIME OVERLOAD AC MODE TO BATTERY MODE AC MODE INVERTER TO BYPASS BATTERY MODE Zero 100-110% for 60 min, 110-125% for 10 min, 126%-150% for 1 min, 150% for 400ms Zero 100-110% for 60 min, 110-125% for 10 min, 126%-150% for 1 min, 150% for 400ms WAVEFORM (BATT. MODE) PURE SINE WAVE PARALLEL CAPACITY BATTERY MODE LOW BATTERY OVERLOAD FAULT ALARM BATTERY MODE Sounding every second Continuously sounding Sounding every 4 seconds Sounding twice every second *When output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%. *Product specifications are subject to change without further notice. 80KVA/80KW 100KVA/100KW 80KL CAPACITY PHASE 60KL SUPERMAX+ 3P/3P 60K~120K ONLINE UPS WITH ISO TX AT OUTPUT MODEL 100KL 120KL 120KVA/120KW External Isolation Transformer Optional SMF (VRLA) / LEAD-ACID BATTERIES 2A~32A (Adjustable) 2A - 24A (Adjustable) 2A~18A (Adjustable) 2A - 36A (Adjustable) 790 x 720 x 1060 974 x 600 x 1600 250 Less than 75dB @ 1 Meter Isolation Trx Inbuilt Isolation Trx Inbuilt Max upto 4-Units, with either Individual battery bank OR Common battery bank SUPER PERFORMANCE HIGH FREQUENCY ONLINE UPS • True double-conversion • DSP technology guarantees high performance • Output power factor 1 • Active power factor correction in all phases at Input • 50Hz/60Hz frequency converter mode • ECO mode operation for energy saving (ECO) • Emergency power off function (EPO) • Generator compatible • SNMP+USB+RS-232 multiple communications • 3-stage extendable charging design for optimized battery performance • Adjustable battery numbers 32-40 battery • Maintenance bypass available • Parallel can be done with either individual battery bank on each UPS, or with Common Battery Bank. • Parallel can be done with either individual battery bank on each UPS, or with Common Battery Bank (But Parallel Share current cables are Optional, need to Order separately for Parallel) • Optional External backfeed Absorb box, for Regenerative type loads like ElevatorsLifts, some CNC Machines etc. The indication of such type of loads on UPS is, it will trip its output detecting UPS internal bus voltage high errorfault. FEATURES: