NEO (Coolcam) POWER PLUG
SMART PLUG USER MANUAL
Introduction
This product can be included and operated in any Z‐Wave network with other Z‐Wave certified
devices from other manufacturers and/or other applications. All non‐battery operated nodes
within the network will act as repeaters regardless of vendor to increase reliability of the
network.
In the front casing, there is button that is used to carry out include, exclude or reset factory
default settings on PCB Board.
When power is first supplied, the LED will flash on and off with yellow alternately every 1 second
intervals within 5 seconds if the detector has not been added a Z‐Wave network, otherwise the
LED will flash on and off 5 times with cyan alternately every 300 millisecond. Please get familiar
with the terms below before starting the operations.
This Plug has function that remembers the relay states, the plug will turn on after power up next
time if the plug is turn on before the power cut‐off.
Add the Device (Smart Plug) to Z‐Wave Network
1. Make sure the sensor is powered.
2. Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or
gateway operating manual)
3. Press the button three times within 1.5 second, the device will enter inclusion mode. And the
LED will flash on and off with green alternately five times within 2 seconds.
Delete the Device (Smart Plug) from Z‐Wave Network
1. Make sure the sensor is powered.
2. Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or
gateway operating manual)
3. Press the button three times within 1.5 second, the device will enter exclusion mode. And
the LED will flash on and off with yellow alternately five times within 2 seconds.
Restore the Device (Smart Plug) to Factory Default Settings
Reset procedure will delete all information on the Z‐Wave network and Z‐Wave controller or
Z‐Wave Gateway, and restore the sensor to factory default settings.
1. Make sure the sensor is powered.
2. Press and hold the button more than 10 seconds until the LED blink with red color.
3. Release the button.
Note: to use the reset procedure only when the primary controller is missing or inoperable.
Associations
Through an association this Plug may control another Z‐Wave network device, e.g. a alarm
device, wall plug, lighting etc.The Wall Plug provides three association groups, and every group
can be support to associated 5 devices max.
GROUP 1 is lifeline service that assigned to plug status – ON/OFF. It enables the Plug to send
reports and readings to Z‐Wave Controller or Z‐Wave Gateway. This Group Support:
NOTIFICATION_REPORT_V4
METER_REPORT_V4
SWITCH_BINARY_REPORT
DEVICE_RESET_LOCALLY_NOTIFICATION
GROUP 2 allows for sending control commands to associated devices such as Siren, relay module,
lighting, etc. If current load is over the max current defined in parameter #3, the Plug will send a
BASIC_SET (0xFF) to associated devices. When current load is normal, plug will send a BASIC_SET
(0x00) to associated devices. This Group Support:
BASIC_SET
GROUP 3 allows for Send Notification to associated devices in this group. This Group Support:
NOTIFICATION_REPORT_V4
Current Load and Energy Consumption
This Plug provides line voltage, current load, power consumption and energy consumption
measuring. These measurement results are sent to Z‐Wave Controller or Z‐Wave Gateway.
Voltage – The Supply Power Voltage For Plug.
Current – The Current for the Electric Device Connect to Plug Consumption.
Power – Power Consumed by an Electric Device in an Instant, unit: Watt(W).
Energy – Energy Consumed by an Electric Device through a Time Period. Most commonly
Measure in Kilowatt‐hours (kWh). One kilowatt‐hour is Equal to One Kilowatt of Power
Consumed over a Period of One Hour, 1kWh = 1000Wh.
NOTE: Energy (kWh) is default scale for Meter Command Class Version 1.
About Notification CC
If current load is great than value defined in parameter #3, plug will send NOTIFICATION CC to
Z‐Wave controller. And if there are some devices associated with this plug, it will receive a
BASIC_SET command from plug.
Notification Report Command:
Event Present:
Command Class: COMMAND_CLASS_NOTIFICATION
Command: NOTIFICATION_REPORT
Notification Type: NOTIFICATION_TYPE_POWER_MANAGEMENT
Event: NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_CURRENT_DETECTED
Event Clear:
Command Class: COMMAND_CLASS_NOTIFICATION
Command: NOTIFICATION_REPORT
Notification Type: NOTIFICATION_TYPE_POWER_MANAGEMENT
Event: NOTIFICATION_EVENT_POWER_MANAGEMENT_NO_EVENT
Over Current Protection Simulating (For Certification Test / Production Test)
When the wall plug is turn on, you can set 0xFF to parameter #100 through Configure CC to
trigger over current protection. If you set, the wall plug will send
NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED to lifeline, and the wall
plug will be turn off, red Led will blink every second. You can press the button once to clear this
alarm and then the wall plug will be back to normal state.
Advanced Configuration
1. Send Meter Report Enable.
This parameter defines Disable/Enable meter report measure data to controller.
Function: Meter Report Enable
Parameter Number: 1.
Parameter Size: 1 Byte
Available Settings: 0, 1.
0– Disable Report,
1‐ Enable Report
Default Setting: 1.
2. Meter Report Interval
This parameter defines interval time (in seconds) that Meter report data to main controller.
Function: Set Report Interval
Parameter Number: 2.
Parameter Size: 2 Byte
Available Settings: 1 – 65535(s).
Default Setting: 300(s)
3. Configure maximum over‐load current.
This parameter defines maximum current the plug can provide to load that be connected to plug.
If the current consumed by load is greater than maximum current, the plug will cut off power,
and send NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED to associated
devices in lifeline. Red Led will blink every seconds until current is normal (less than Parameter
#3). You must remove the loader and turn on the Plug (press the button once) to enable current
monitor and clear NOTIFICATION ALARM.
This parameter value must be great than #4. If user set this parameter to default by Configure CC,
the parameter #4 will be set to default value.
Function: Set the upper current threshold.
Parameter Number: 3.
Parameter Size: 1 Byte
Available Settings: 1 – 16 (Ampere).
Default Setting: 13(A).
4. Configure maximum Alarm current.
This parameter defines maximum current, if the current plug provide to load is great than this
parameter, the plug will light yellow LED, but plug cannot cut‐off power.
This parameter value must be less than parameter #3. If user set this parameter to default by
Configure CC, the parameter #3 will be set to default value.
Function: Set Alarm upper current threshold.
Parameter Number: 4.
Parameter Size: 1 Byte
Available Settings: 1 – Parameter #3 (Ampere).
Default Setting: 12(A).
5. Led Display Enable
This parameter defines the LED indication Function ON/OFF. This parameter can be configured
with 0 or 1, where 0 means disable LED indication Function and will always be turn‐off, and 1
means enable LED Function.
Function: LED Enable/Disable
Parameter Number: 5.
Parameter Size: 1 Byte
Available Settings: 0, 1.
Default Setting: 1.
6. Configure report by Current Changed
This parameter defines by how much current changed must change to be reported to the Z‐Wave
Controller or Z‐Wave Gateway, in percents. If the rate of power consumed change ratio is greater
than this parameter, the plug will report the results, voltage, current, power and energy, that plug
measure to Z‐Wave Controller or Z‐Wave Gateway.
Function: Meter Reporting Setting
Parameter Number: 6.
Parameter Size: 1 Byte
Available Settings: 1 – 100 (%).
Default Setting: 5(%).
7. Remember Relay ON/OFF status
This parameter defined the relay status if remember or not. If remembered, the plug will restore
the relay status last power off when the plug supply power next time.
Function: Remember Relay Status
Parameter Number: 7.
Parameter Size: 1 Byte
Available Settings: 0 , 1
0 – Don’t Remember, the relay will keep OFF when Plug Supply Power.
1 – Remember the Relay Status.
Default Setting: 1.
8. Configure Plug Time switch Function
This parameter defines the timer function Enable/Disable. This parameter can be configured with
0 or 1, where 0 means disable time switch function and 1 enable. The time period will be defined
in parameter #9.
If this parameter is Set to 1, and when turn the plug relay on, the timer in plug start run with time
period defined in parameter #9 and the plug will turn the relay off.
Function: Time switch Configure
Parameter Number: 8.
Parameter Size: 1 Byte
Available Settings: 0, 1
0– Time switch Disable.
1– Time switch Enable.
Default Setting: 0
9. Configure Time switch Period
This parameter defines the time period that plug time switch off. This parameter can be
configured 1 ~ 65535(in minutes). If Parameter #9 is set to ‘1’, and relay is turn‐on, the relay will
be turn‐off after delay this parameter.
Function: Time switch Configure
Parameter Number: 9.
Parameter Size: 2 Byte
Available Settings: 1 ~ 65535(minutes).
Default Setting: 150(min)
10. Button On/Off Enable
This parameter defines the button on/off function is enabled or not on the top of the wall plug.
This parameter can be configured 0 and 1. If this parameter is set to ‘1’, users can turn on and off
the wall plug by pressing the button on the top of the wall plug. If this parameter is set to ‘0’, the
wall plug cannot be turned on and off by pressing the button.
Function: Enable Button On/Off
Parameter Number: 10.
Parameter Size: 1 Byte
Available Settings: 0, 1.
Default Setting: 1
LED Color Indicator
LED Color Led Display Status Description
Pink
Blink 5 Times(1s Interval) Power on and Not Add in Z‐Wave Network
Blink 5 Times(500ms Interval) Send Node Info when Press Button tripled.
Blue Blink 5 Times(300ms Interval) Power on and Already Add in a Z‐Wave Network
Blink 5 Times(500ms Interval) Press Button tripled, Adding the Plug in a Z‐Wave
Yellow
Network.
Always Light The Load Current is Arrived Alarm limit(Param
#4)
Blink 1 Time Press the Button Long Time, Reset the Plug to
Red
restore default settings
Blink with 1 second interval The Load Current is great than Max Load defines
in Param #3.
Green Always Light The Plug is Power on.
Manufacture ID: 0x0258
Product ID: 0x0087
Command Classes
The Plug supports Command Classes as Below:
0 COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
0 COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
0 COMMAND_CLASS_VERSION (V2)
0 COMMAND_CLASS_ASSOCIATION (V2)
0 COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
0 COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
0 COMMAND_CLASS_POWERLEVEL (V1)
0 COMMAND_CLASS_SWITCH_BINARY (V1)
0 COMMAND_CLASS_NOTIFICATION (V4)
0 COMMAND_CLASS_METER (V4)
0 COMMAND_CLASS_CONFIGURATION (V1)
0 COMMAND_CLASS_SWITCH_ALL (V1)
0 COMMAND_CLASS_BASIC (V1)
SPECIFICATIONS
Power Supply: AC110 ~ 230V(±10%), 50/60Hz
Rate Load Current: 13A, 110‐230V, 50/60Hz – Continuous Load
16A, 110‐230V, 50/60Hz – Momentary Load
Power Consumption: 0.13W
EU Standards Compliance:
Radio Protocol: Z‐Wave
Radio Frequency: EU – 868.4MHz
US – 908.4MHz
Valid Range: Up to 60m outdoors
Up to 30m indoors (Depending on terrain and building
structure)
Operational Temperature: 0 – 40 ℃

More Related Content

PPTX
Fault Tolerance System
PDF
Artificial Neural Network Lect4 : Single Layer Perceptron Classifiers
PPTX
distributed Computing system model
PDF
Artificial Neural Networks Lect5: Multi-Layer Perceptron & Backpropagation
PDF
Some important tips for control systems
PPTX
Heterogeneous mesh network (ad hoc)
PPTX
Bandwidth utilization
PPTX
Convolutional Neural Networks
Fault Tolerance System
Artificial Neural Network Lect4 : Single Layer Perceptron Classifiers
distributed Computing system model
Artificial Neural Networks Lect5: Multi-Layer Perceptron & Backpropagation
Some important tips for control systems
Heterogeneous mesh network (ad hoc)
Bandwidth utilization
Convolutional Neural Networks

What's hot (20)

PPTX
FUNCTION APPROXIMATION
PPTX
Machine learning workshop using Orange datamining framework
PDF
Data communication lab manual
PPTX
Supervised learning network
PPTX
Unit 2 data link control
PPT
MACHINE LEARNING LIFE CYCLE
PPT
ch-10.ppt
PPTX
Neuro-fuzzy systems
PDF
Switch cisco catalyst 2950
PPTX
Virtualization in Cloud Computing and Machine reference Model
PPT
1.4. ALOHA, CSMA , CSMACD, CSMACA .ppt
PPTX
Distributed DBMS - Unit 9 - Distributed Deadlock & Recovery
PPTX
Chapter 4. using the command line interface
PPTX
Data reduction
PPTX
Wsn routing protocol
PPTX
Producer consumer problem operating system
PDF
K means and dbscan
PPTX
HDLC(High level Data Link Control)
PPTX
Credit Card Fraud Detection - Anomaly Detection
PPTX
Threats in wireless sensor networks
FUNCTION APPROXIMATION
Machine learning workshop using Orange datamining framework
Data communication lab manual
Supervised learning network
Unit 2 data link control
MACHINE LEARNING LIFE CYCLE
ch-10.ppt
Neuro-fuzzy systems
Switch cisco catalyst 2950
Virtualization in Cloud Computing and Machine reference Model
1.4. ALOHA, CSMA , CSMACD, CSMACA .ppt
Distributed DBMS - Unit 9 - Distributed Deadlock & Recovery
Chapter 4. using the command line interface
Data reduction
Wsn routing protocol
Producer consumer problem operating system
K means and dbscan
HDLC(High level Data Link Control)
Credit Card Fraud Detection - Anomaly Detection
Threats in wireless sensor networks
Ad

Similar to Neo coolcam - smart-plug user guide v2 - Zwave (20)

PDF
Qubino flush 1 relay plus user manual v1.0 eng1
PDF
Manual ip44 popp_en
PDF
Micro switch module qubino manual
PDF
Manual Qubino smart meter plus
PDF
Mini Socket Dimmer Z-Wave Everspring manual
PDF
Mini jack on off and counter z wave plus everspring
PDF
Qubino flush 1D relay user manual
PDF
In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
PDF
Pop 123610 manual
PDF
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual english
PDF
Micromodule Mural On/Off Z-Wave Plus AN179 Smart Home Europe manual english
PDF
Mini price on off z wave plus everspring
PDF
Manual_AD147_20140728.pdf
PDF
Wall plug switch with metering po pp start guide
PDF
MCO-21-TPS-411 Manual
PDF
Philio_pan04_User manual
PDF
Micro double switch module qubino manual
PDF
Aeotec Multisensor 7 Manual
PDF
Manual Zipato PAB01
PDF
Ph pan04-zipato-micro-module-switch-double-user-manual-v1.4
Qubino flush 1 relay plus user manual v1.0 eng1
Manual ip44 popp_en
Micro switch module qubino manual
Manual Qubino smart meter plus
Mini Socket Dimmer Z-Wave Everspring manual
Mini jack on off and counter z wave plus everspring
Qubino flush 1D relay user manual
In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
Pop 123610 manual
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual english
Micromodule Mural On/Off Z-Wave Plus AN179 Smart Home Europe manual english
Mini price on off z wave plus everspring
Manual_AD147_20140728.pdf
Wall plug switch with metering po pp start guide
MCO-21-TPS-411 Manual
Philio_pan04_User manual
Micro double switch module qubino manual
Aeotec Multisensor 7 Manual
Manual Zipato PAB01
Ph pan04-zipato-micro-module-switch-double-user-manual-v1.4
Ad

More from Thierry Zoller (11)

PDF
BLtouch marlin configuration
PDF
Cansecwest - The Death of AV defence in depth
PDF
Heise Security - Scheunentor Bluetooth
PDF
23c3 Bluetooth hacking revisited
PDF
Hack.lu 2006 - All your Bluetooth is belong to us
PDF
Managing Application Security Risk in Enterprises - Thoughts and recommendations
PDF
All your Bluetooth is belong to us - the rest too.
PDF
IPV6 - Threats and Countermeasures / Crash Course
PDF
The Rise of the Vulnerability Markets - History, Impacts, Mitigations - Thier...
PDF
SSL Audit - The SSL / TLS Scanner
PDF
The TLS/SSLv3 renegotiation vulnerability explained
BLtouch marlin configuration
Cansecwest - The Death of AV defence in depth
Heise Security - Scheunentor Bluetooth
23c3 Bluetooth hacking revisited
Hack.lu 2006 - All your Bluetooth is belong to us
Managing Application Security Risk in Enterprises - Thoughts and recommendations
All your Bluetooth is belong to us - the rest too.
IPV6 - Threats and Countermeasures / Crash Course
The Rise of the Vulnerability Markets - History, Impacts, Mitigations - Thier...
SSL Audit - The SSL / TLS Scanner
The TLS/SSLv3 renegotiation vulnerability explained

Recently uploaded (20)

PDF
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
PPTX
Tartificialntelligence_presentation.pptx
PDF
Network Security Unit 5.pdf for BCA BBA.
PPT
Teaching material agriculture food technology
PDF
MIND Revenue Release Quarter 2 2025 Press Release
PDF
A comparative study of natural language inference in Swahili using monolingua...
PPTX
OMC Textile Division Presentation 2021.pptx
PDF
Univ-Connecticut-ChatGPT-Presentaion.pdf
PDF
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
PPTX
TechTalks-8-2019-Service-Management-ITIL-Refresh-ITIL-4-Framework-Supports-Ou...
PPTX
TLE Review Electricity (Electricity).pptx
PDF
Diabetes mellitus diagnosis method based random forest with bat algorithm
PDF
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
PDF
Accuracy of neural networks in brain wave diagnosis of schizophrenia
PDF
Getting Started with Data Integration: FME Form 101
PPTX
SOPHOS-XG Firewall Administrator PPT.pptx
PDF
Encapsulation_ Review paper, used for researhc scholars
PDF
Mushroom cultivation and it's methods.pdf
PDF
Spectral efficient network and resource selection model in 5G networks
PPTX
Spectroscopy.pptx food analysis technology
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
Tartificialntelligence_presentation.pptx
Network Security Unit 5.pdf for BCA BBA.
Teaching material agriculture food technology
MIND Revenue Release Quarter 2 2025 Press Release
A comparative study of natural language inference in Swahili using monolingua...
OMC Textile Division Presentation 2021.pptx
Univ-Connecticut-ChatGPT-Presentaion.pdf
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
TechTalks-8-2019-Service-Management-ITIL-Refresh-ITIL-4-Framework-Supports-Ou...
TLE Review Electricity (Electricity).pptx
Diabetes mellitus diagnosis method based random forest with bat algorithm
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
Accuracy of neural networks in brain wave diagnosis of schizophrenia
Getting Started with Data Integration: FME Form 101
SOPHOS-XG Firewall Administrator PPT.pptx
Encapsulation_ Review paper, used for researhc scholars
Mushroom cultivation and it's methods.pdf
Spectral efficient network and resource selection model in 5G networks
Spectroscopy.pptx food analysis technology

Neo coolcam - smart-plug user guide v2 - Zwave

  • 1. NEO (Coolcam) POWER PLUG SMART PLUG USER MANUAL Introduction This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. In the front casing, there is button that is used to carry out include, exclude or reset factory default settings on PCB Board. When power is first supplied, the LED will flash on and off with yellow alternately every 1 second intervals within 5 seconds if the detector has not been added a Z‐Wave network, otherwise the LED will flash on and off 5 times with cyan alternately every 300 millisecond. Please get familiar with the terms below before starting the operations. This Plug has function that remembers the relay states, the plug will turn on after power up next time if the plug is turn on before the power cut‐off. Add the Device (Smart Plug) to Z‐Wave Network 1. Make sure the sensor is powered. 2. Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or gateway operating manual) 3. Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off with green alternately five times within 2 seconds. Delete the Device (Smart Plug) from Z‐Wave Network 1. Make sure the sensor is powered. 2. Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or gateway operating manual) 3. Press the button three times within 1.5 second, the device will enter exclusion mode. And the LED will flash on and off with yellow alternately five times within 2 seconds. Restore the Device (Smart Plug) to Factory Default Settings Reset procedure will delete all information on the Z‐Wave network and Z‐Wave controller or Z‐Wave Gateway, and restore the sensor to factory default settings. 1. Make sure the sensor is powered. 2. Press and hold the button more than 10 seconds until the LED blink with red color. 3. Release the button. Note: to use the reset procedure only when the primary controller is missing or inoperable.
  • 2. Associations Through an association this Plug may control another Z‐Wave network device, e.g. a alarm device, wall plug, lighting etc.The Wall Plug provides three association groups, and every group can be support to associated 5 devices max. GROUP 1 is lifeline service that assigned to plug status – ON/OFF. It enables the Plug to send reports and readings to Z‐Wave Controller or Z‐Wave Gateway. This Group Support: NOTIFICATION_REPORT_V4 METER_REPORT_V4 SWITCH_BINARY_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION GROUP 2 allows for sending control commands to associated devices such as Siren, relay module, lighting, etc. If current load is over the max current defined in parameter #3, the Plug will send a BASIC_SET (0xFF) to associated devices. When current load is normal, plug will send a BASIC_SET (0x00) to associated devices. This Group Support: BASIC_SET GROUP 3 allows for Send Notification to associated devices in this group. This Group Support: NOTIFICATION_REPORT_V4 Current Load and Energy Consumption This Plug provides line voltage, current load, power consumption and energy consumption measuring. These measurement results are sent to Z‐Wave Controller or Z‐Wave Gateway. Voltage – The Supply Power Voltage For Plug. Current – The Current for the Electric Device Connect to Plug Consumption. Power – Power Consumed by an Electric Device in an Instant, unit: Watt(W). Energy – Energy Consumed by an Electric Device through a Time Period. Most commonly Measure in Kilowatt‐hours (kWh). One kilowatt‐hour is Equal to One Kilowatt of Power Consumed over a Period of One Hour, 1kWh = 1000Wh. NOTE: Energy (kWh) is default scale for Meter Command Class Version 1. About Notification CC If current load is great than value defined in parameter #3, plug will send NOTIFICATION CC to Z‐Wave controller. And if there are some devices associated with this plug, it will receive a BASIC_SET command from plug. Notification Report Command: Event Present: Command Class: COMMAND_CLASS_NOTIFICATION
  • 3. Command: NOTIFICATION_REPORT Notification Type: NOTIFICATION_TYPE_POWER_MANAGEMENT Event: NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_CURRENT_DETECTED Event Clear: Command Class: COMMAND_CLASS_NOTIFICATION Command: NOTIFICATION_REPORT Notification Type: NOTIFICATION_TYPE_POWER_MANAGEMENT Event: NOTIFICATION_EVENT_POWER_MANAGEMENT_NO_EVENT Over Current Protection Simulating (For Certification Test / Production Test)
  • 4. When the wall plug is turn on, you can set 0xFF to parameter #100 through Configure CC to trigger over current protection. If you set, the wall plug will send NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED to lifeline, and the wall plug will be turn off, red Led will blink every second. You can press the button once to clear this alarm and then the wall plug will be back to normal state. Advanced Configuration 1. Send Meter Report Enable. This parameter defines Disable/Enable meter report measure data to controller. Function: Meter Report Enable Parameter Number: 1. Parameter Size: 1 Byte Available Settings: 0, 1. 0– Disable Report, 1‐ Enable Report Default Setting: 1. 2. Meter Report Interval This parameter defines interval time (in seconds) that Meter report data to main controller. Function: Set Report Interval Parameter Number: 2. Parameter Size: 2 Byte Available Settings: 1 – 65535(s). Default Setting: 300(s) 3. Configure maximum over‐load current. This parameter defines maximum current the plug can provide to load that be connected to plug. If the current consumed by load is greater than maximum current, the plug will cut off power, and send NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED to associated devices in lifeline. Red Led will blink every seconds until current is normal (less than Parameter #3). You must remove the loader and turn on the Plug (press the button once) to enable current monitor and clear NOTIFICATION ALARM. This parameter value must be great than #4. If user set this parameter to default by Configure CC, the parameter #4 will be set to default value. Function: Set the upper current threshold. Parameter Number: 3. Parameter Size: 1 Byte Available Settings: 1 – 16 (Ampere).
  • 5. Default Setting: 13(A). 4. Configure maximum Alarm current.
  • 6. This parameter defines maximum current, if the current plug provide to load is great than this parameter, the plug will light yellow LED, but plug cannot cut‐off power. This parameter value must be less than parameter #3. If user set this parameter to default by Configure CC, the parameter #3 will be set to default value. Function: Set Alarm upper current threshold. Parameter Number: 4. Parameter Size: 1 Byte Available Settings: 1 – Parameter #3 (Ampere). Default Setting: 12(A). 5. Led Display Enable This parameter defines the LED indication Function ON/OFF. This parameter can be configured with 0 or 1, where 0 means disable LED indication Function and will always be turn‐off, and 1 means enable LED Function. Function: LED Enable/Disable Parameter Number: 5. Parameter Size: 1 Byte Available Settings: 0, 1. Default Setting: 1. 6. Configure report by Current Changed This parameter defines by how much current changed must change to be reported to the Z‐Wave Controller or Z‐Wave Gateway, in percents. If the rate of power consumed change ratio is greater than this parameter, the plug will report the results, voltage, current, power and energy, that plug measure to Z‐Wave Controller or Z‐Wave Gateway. Function: Meter Reporting Setting Parameter Number: 6. Parameter Size: 1 Byte Available Settings: 1 – 100 (%). Default Setting: 5(%). 7. Remember Relay ON/OFF status This parameter defined the relay status if remember or not. If remembered, the plug will restore the relay status last power off when the plug supply power next time. Function: Remember Relay Status Parameter Number: 7. Parameter Size: 1 Byte
  • 7. Available Settings: 0 , 1 0 – Don’t Remember, the relay will keep OFF when Plug Supply Power. 1 – Remember the Relay Status.
  • 8. Default Setting: 1. 8. Configure Plug Time switch Function This parameter defines the timer function Enable/Disable. This parameter can be configured with 0 or 1, where 0 means disable time switch function and 1 enable. The time period will be defined in parameter #9. If this parameter is Set to 1, and when turn the plug relay on, the timer in plug start run with time period defined in parameter #9 and the plug will turn the relay off. Function: Time switch Configure Parameter Number: 8. Parameter Size: 1 Byte Available Settings: 0, 1 0– Time switch Disable. 1– Time switch Enable. Default Setting: 0 9. Configure Time switch Period This parameter defines the time period that plug time switch off. This parameter can be configured 1 ~ 65535(in minutes). If Parameter #9 is set to ‘1’, and relay is turn‐on, the relay will be turn‐off after delay this parameter. Function: Time switch Configure Parameter Number: 9. Parameter Size: 2 Byte Available Settings: 1 ~ 65535(minutes). Default Setting: 150(min) 10. Button On/Off Enable This parameter defines the button on/off function is enabled or not on the top of the wall plug. This parameter can be configured 0 and 1. If this parameter is set to ‘1’, users can turn on and off the wall plug by pressing the button on the top of the wall plug. If this parameter is set to ‘0’, the wall plug cannot be turned on and off by pressing the button. Function: Enable Button On/Off Parameter Number: 10. Parameter Size: 1 Byte Available Settings: 0, 1. Default Setting: 1
  • 9. LED Color Indicator LED Color Led Display Status Description Pink Blink 5 Times(1s Interval) Power on and Not Add in Z‐Wave Network Blink 5 Times(500ms Interval) Send Node Info when Press Button tripled. Blue Blink 5 Times(300ms Interval) Power on and Already Add in a Z‐Wave Network Blink 5 Times(500ms Interval) Press Button tripled, Adding the Plug in a Z‐Wave Yellow Network. Always Light The Load Current is Arrived Alarm limit(Param #4) Blink 1 Time Press the Button Long Time, Reset the Plug to Red restore default settings Blink with 1 second interval The Load Current is great than Max Load defines in Param #3. Green Always Light The Plug is Power on. Manufacture ID: 0x0258 Product ID: 0x0087 Command Classes The Plug supports Command Classes as Below: 0 COMMAND_CLASS_ZWAVEPLUS_INFO (V2) 0 COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2) 0 COMMAND_CLASS_VERSION (V2) 0 COMMAND_CLASS_ASSOCIATION (V2) 0 COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1) 0 COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1) 0 COMMAND_CLASS_POWERLEVEL (V1) 0 COMMAND_CLASS_SWITCH_BINARY (V1) 0 COMMAND_CLASS_NOTIFICATION (V4) 0 COMMAND_CLASS_METER (V4) 0 COMMAND_CLASS_CONFIGURATION (V1) 0 COMMAND_CLASS_SWITCH_ALL (V1) 0 COMMAND_CLASS_BASIC (V1) SPECIFICATIONS Power Supply: AC110 ~ 230V(±10%), 50/60Hz Rate Load Current: 13A, 110‐230V, 50/60Hz – Continuous Load 16A, 110‐230V, 50/60Hz – Momentary Load Power Consumption: 0.13W EU Standards Compliance: Radio Protocol: Z‐Wave Radio Frequency: EU – 868.4MHz US – 908.4MHz
  • 10. Valid Range: Up to 60m outdoors Up to 30m indoors (Depending on terrain and building structure) Operational Temperature: 0 – 40 ℃