SlideShare a Scribd company logo
Optimizing gas turbine performance with
precise humidity measurements
Ensuring gas turbines run at maximum efficiency is a primary goal for operators. In the current
economic climate, anything that increases productivity, and hence profit, is clearly welcome.
From an environmental point of view, it is also important that turbines run as efficiently – and
produce as few emissions – as possible. Fortunately, there are several ways to improve gas
turbine output. Controlling the humidity and temperature of air entering the combustion inlet
is one of the most important, as it has a direct effect on the turbine’s efficiency, emissions, and
operational reliability.
/ APPLICATION NOTE
Cooler, denser air
increases output and
efficiency
In terms of gas turbine efficiency, the
effect of air density is well known:
denser intake air increases mass
flow rate, which consequently results
in improved turbine output and
efficiency. Air density is inversely
proportional to temperature,
meaning that rising temperatures
decrease air density and therefore
reduce gas turbine efficiency
and power.
Inlet-air cooling, especially in warm
and hot environments, is commonly
used to compensate for the efficiency
loss caused by high air temperature.
Even a small reduction in air
temperature can lead to a significant
increase in power output. A 1°C
reduction in air temperature can
increase output by up to 0.5%.
There are several techniques that are
used to cool intake air. A common
solution is a fogger, a system that
injects water into the airflow through
nozzles, causing the air to cool as the
water droplets evaporate.
A secondary benefit of fogging is that
the increased humidity of the air
reduces the NOx emissions produced
by the combustion process.
Apart from inlet-air cooling in warm
or hot conditions, humidity can also
be a critical factor in avoiding icing
in cold climates. If humid air is close
to freezing, anti-icing systems are
needed to protect the compressor
from the damage that fast-moving ice
particles would cause.
Optimal control needs
accurate humidity
information
Given the high speed of air within the
air inlet system, water droplets and
ice particles must be prevented from
entering the compressor and turbine
to avoid costly damage and erosion.
In practice, this means that the air
humidity needs to be kept below
saturation levels. In other words, to
avoid condensation, the dew point
temperature of the air entering the
system has to be below the air and
surface temperatures in the system.
The control system has to have
a safety margin to allow for
measurement uncertainties as well as
fluctuations and irregularities in the
properties of the air being measured.
However, the wider the margins that
are needed due to measurement
uncertainties, the greater the
efficiency potential that is lost. This
is where a high level of measurement
reliability really pays off. Accurately
measuring the dew point enables
cooling and fogging, or even heating,
to be performed as close as possible
to the condensation or icing limit
within the system.
Different ways of
expressing humidity
Depending on the application,
different terms are used to express
humidity. These include, but are not
limited to, relative humidity, dew
point temperature, and wet bulb
temperature.
Relative humidity (RH) is the
ratio of the water vapor’s partial
pressure to its saturated pressure
at a particular temperature. RH is
expressed as a percentage and is
generally used to describe ambient
air humidity. The drawback of using
RH is that it is heavily dependent
on temperature. For example, if RH
is 85% and the temperature 20°C, a
decrease in the air temperature of
only 2°C changes the RH to 96%. If
RH is used to measure air humidity
in a turbine inlet, this dependence
has to be kept in mind because even
without cooling or heating, the air
temperature changes in the air inlet
system. The main effect is cooling
due to the acceleration of air at the
compressor bell mouth, which can
cause a temperature drop of several
°C. Due to this cooling effect there is
still a risk of ice formation even when
the ambient temperature is above 0°C.
A 1°C reduction in air temperature
can increase output by up to 0.5%.
Turbine output power can be increased with accurate inlet air humidity measurements.
For more information, visit
www.vaisala.com or contact
us at sales@vaisala.com
Ref. B211073EN EN-A ©Vaisala 2010
This material is subject to copyright protection, with all copyrights
retained by Vaisala and its individual partners. All rights reserved.
Any logos and/or product names are trademarks of Vaisala or
its individual partners. The reproduction, transfer, distribution or
storage of information contained in this brochure in any form
without the prior written consent of Vaisala is strictly prohibited.
All specifications — technical included — are subject to change
without notice.
Products suitable for
combustion inlet air
monitoring:
▪ Vaisala HUMICAP® Humidity
and Temperature Transmitter
Series HMT330 and Vaisala
Combined Pressure, Humidity
and Temperature Transmitter
PTU300. Both series have a
heated probe option, chemical
purge function, and Vaisala
HUMICAP® thin-film polymer
technology.
▪ To check functionality in
the field, Vaisala HUMICAP®
Hand-Held Humidity and
Temperature Meter HM70.
▪ To protect direct water
splashes from entering the
humidity sensor, Vaisala
HUMICAP® Turbine Mounting
Kit HMT300TMK.
The dew point temperature (Td)
is the temperature at which air,
when cooled at constant pressure,
becomes fully saturated with water
vapor resulting in the formation of
liquid water known as condensation.
At 100% RH, the ambient temperature
is the same as the dew point
temperature, but when the dew
point temperature is lower than
the ambient temperature, the air
becomes drier and therefore there
is less risk of condensation forming.
Two main benefits of using Td are
that it is not temperature dependent
and it directly provides the margin to
condensing conditions.
Wet bulb temperature (Tw) is
the temperature indicated by a
thermometer wrapped in a wet
sheath. The wet bulb temperature
and ambient temperature can be
used to calculate relative humidity
or the dew point. Tw is a traditional
way to determine humidity but has
largely been replaced by direct
measurements as accuracy is limited
and the method requires some skill
to use and maintain.
All the above humidity parameters
are pressure dependent, but for air
intake applications typical drops
in pressure are so small that they
do not have a significant effect. For
example, at 20°C and 1013 mbar, a
reduction in pressure of 20 mbar
causes a reduction of 1.7% in RH
or 0.3°C in Td.
Factors affecting accuracy
There are many factors that affect
humidity measurement accuracy –
basic sensing technology being the
most obvious one. However thin-film
polymer sensors have been proven
to satisfy the most critical needs
in inlet air monitoring: accuracy,
robustness, long-term stability, and
low maintenance requirements.
Because air in the inlet may be very
close to saturation, and perhaps even
forming condensation, the sensor
has to maintain accuracy even in
these conditions. One challenge for
a humidity sensor in condensing
air is that if the sensor gets wet, the
measurements will continue to show
saturated conditions until the sensor
dries – even though the air itself is
no longer saturated. To overcome
this problem, Vaisala has developed
patented heating probe technology.
This ensures that the temperature
of the probe is kept above the
surrounding air temperature in order
to avoid condensation on the
sensor itself.
Depending on the system and exact
installation position, direct water
splashes may also wet the humidity
sensor. Special mounting accessories
are available to prevent this
from happening.
At power plants and polluted
environments, the intake air may
contain contaminants, which can
affect long-term sensor accuracy. To
overcome this challenge, advanced
sensors can be configured with a
chemical purge function, which cleans
the sensor element automatically by
evaporating possible contaminants.

More Related Content

PDF
Gas phase oxygen measurement systems
PDF
Continuous On-Line Microbial Monitoring of Pharmaceutical Waters
PPT
GPO Customer Presentation
PDF
Process Analytics Product Catalog
PDF
Combustion Analyzer to Add Extra Layer of Safety to Burner Management System
PDF
8000 Oxygen Permeation Analysers
PDF
Process Brochure For Industry
PDF
From process to emission
Gas phase oxygen measurement systems
Continuous On-Line Microbial Monitoring of Pharmaceutical Waters
GPO Customer Presentation
Process Analytics Product Catalog
Combustion Analyzer to Add Extra Layer of Safety to Burner Management System
8000 Oxygen Permeation Analysers
Process Brochure For Industry
From process to emission

What's hot (20)

PDF
Gs6000 Headspace Analysers
PDF
Line Card for Alliance Technical Sales - Updated 12/2016
PDF
CEMSI Cement Solutions
PDF
Prevex Flammability Analyzer Product Specification
PDF
E+H - inline quality measurement
PDF
Environmental Monitoring
PDF
Mettler Toledo Process Analytics Catalog 2018-2019
PDF
Testo Measurement Solutions for Pharma Industry Applications
PDF
Safeguarding CO2 Measurements: How Intelligent and Automatic Sensor Protectio...
PDF
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
PDF
Whey, Water and CIP Detergent?
PDF
E+H - Global Offering for LIfe Sciences
PDF
E+H Life Sciences Magazine May 2015
PDF
E+H brochure - Safe Choice for Food & Beverage
PPT
Septitech Presentation General
PDF
Katalog fluke-hvac-tools-indoor-air-quality-by-tridinamika
PPTX
SeptiTech STAAR Denitrification Wastewater Presentation
PDF
VEGA Pressure & Level Measurement - Paper Industry Applications
PPT
GPO Application Dataset
PDF
E+H - Making accurate PH measurements
Gs6000 Headspace Analysers
Line Card for Alliance Technical Sales - Updated 12/2016
CEMSI Cement Solutions
Prevex Flammability Analyzer Product Specification
E+H - inline quality measurement
Environmental Monitoring
Mettler Toledo Process Analytics Catalog 2018-2019
Testo Measurement Solutions for Pharma Industry Applications
Safeguarding CO2 Measurements: How Intelligent and Automatic Sensor Protectio...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Whey, Water and CIP Detergent?
E+H - Global Offering for LIfe Sciences
E+H Life Sciences Magazine May 2015
E+H brochure - Safe Choice for Food & Beverage
Septitech Presentation General
Katalog fluke-hvac-tools-indoor-air-quality-by-tridinamika
SeptiTech STAAR Denitrification Wastewater Presentation
VEGA Pressure & Level Measurement - Paper Industry Applications
GPO Application Dataset
E+H - Making accurate PH measurements
Ad

Viewers also liked (12)

PDF
Jogler magnetic level gauge brochure
PDF
Technical Reference for Thermocouples and Reistance Temperature Detectors (RTD)
PDF
Magnetostrictive Liquid Level Transmitter for Process Measurement and Control
PDF
Optimizing chemcial industry processes
PDF
Intelligent Sensor Management From Ingold
PDF
PID Controllers from Precision Digital
PDF
Pharmaceutical Manufacturing Case Study: Refurbish Old Bioreactor
PDF
Laser based level transmitter for industrial process measurement
PDF
Vaisala HMT330 Series IndustrialTemperature and Humidity Transmitters
PDF
Intelligent Sensor Management For Inline Process Analytics
PDF
Magnetostrictive level transmitter added to magnetic level gauge
PDF
Moisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Jogler magnetic level gauge brochure
Technical Reference for Thermocouples and Reistance Temperature Detectors (RTD)
Magnetostrictive Liquid Level Transmitter for Process Measurement and Control
Optimizing chemcial industry processes
Intelligent Sensor Management From Ingold
PID Controllers from Precision Digital
Pharmaceutical Manufacturing Case Study: Refurbish Old Bioreactor
Laser based level transmitter for industrial process measurement
Vaisala HMT330 Series IndustrialTemperature and Humidity Transmitters
Intelligent Sensor Management For Inline Process Analytics
Magnetostrictive level transmitter added to magnetic level gauge
Moisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Ad

Similar to Optimizing gas turbine performance with precise humidity measurements (20)

PPTX
Energy efficiency improvement opportunities in compressed air systems
PDF
CDS R 02 Drying Article Im Ci August 2010
PPT
Compressed air and refrigeration system
PDF
CDS R-02 Presentation
PDF
Uscatoare cu ciclu frigorifer CECCATO
PPTX
Ventilation
PPT
properties of air and psychrometric process..ppt
PDF
COMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIES
PPTX
Air Conditioning Psychrometric_me1101.pptx
PPTX
RIS Refrigeration & Air Chap_14_lecture.pptx
PPTX
PDF
Armstrong hb501
PDF
How to choose the right parameter for humidity
DOCX
Air conditioning and refrigeration systems
PPTX
Airconditioning
PDF
Unit-4 part 2.pdf
PDF
Unit-4 part 2.pdf
PDF
humidity control 12345674542445324553223
PPT
Pneumatic1day
PDF
inverter compressor
Energy efficiency improvement opportunities in compressed air systems
CDS R 02 Drying Article Im Ci August 2010
Compressed air and refrigeration system
CDS R-02 Presentation
Uscatoare cu ciclu frigorifer CECCATO
Ventilation
properties of air and psychrometric process..ppt
COMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIES
Air Conditioning Psychrometric_me1101.pptx
RIS Refrigeration & Air Chap_14_lecture.pptx
Armstrong hb501
How to choose the right parameter for humidity
Air conditioning and refrigeration systems
Airconditioning
Unit-4 part 2.pdf
Unit-4 part 2.pdf
humidity control 12345674542445324553223
Pneumatic1day
inverter compressor

More from Alliance Technical Sales, Inc. (20)

PDF
Jogler Magnetic Level Gauge, Magnetostrictive Level Transmitter, and Laser Le...
PDF
Electric Heating and Freeze Protection Solutions
PDF
Jogler Industrial Level Measurement Products Catalog
PDF
Pharmaceutical Waters Guide for Regulatory Compliance, Analysis and Real-Time...
PDF
Analytical Measurement Solutions for Optimization of Your Brewing Process
PDF
Pre-Assembled Self-Regulating Heating Cable
PDF
Jogler Liquid Level Gauges, Indicators and Transmitters
PDF
Pharmaceutical Water Instrumentation Guide
PDF
Pharmaceutical Water Guide - Instrumentation
PDF
Indigo 200 Series Transmitters
PDF
Laser Level Transmitter for Process Measurement and Control
PDF
Portable pH Meter for Process Measurement
PDF
Dissolved Solids Analyzer Refractometer
PDF
Temperature and Relative Humidity Data Logger
PDF
TOC Total Organic Carbon Analyzer
PDF
Surface Temperature Sensors and Transmitters for Industrial Applications
PDF
Guide to Oxygen Measurement in Industrial Process Applications
PDF
Turbidity Standards for Turbidity Measurement
PDF
Automated pH Sensor Cleaning and Calibration
PDF
Folded Path Tunable Diode Laser Gas Analyzers
Jogler Magnetic Level Gauge, Magnetostrictive Level Transmitter, and Laser Le...
Electric Heating and Freeze Protection Solutions
Jogler Industrial Level Measurement Products Catalog
Pharmaceutical Waters Guide for Regulatory Compliance, Analysis and Real-Time...
Analytical Measurement Solutions for Optimization of Your Brewing Process
Pre-Assembled Self-Regulating Heating Cable
Jogler Liquid Level Gauges, Indicators and Transmitters
Pharmaceutical Water Instrumentation Guide
Pharmaceutical Water Guide - Instrumentation
Indigo 200 Series Transmitters
Laser Level Transmitter for Process Measurement and Control
Portable pH Meter for Process Measurement
Dissolved Solids Analyzer Refractometer
Temperature and Relative Humidity Data Logger
TOC Total Organic Carbon Analyzer
Surface Temperature Sensors and Transmitters for Industrial Applications
Guide to Oxygen Measurement in Industrial Process Applications
Turbidity Standards for Turbidity Measurement
Automated pH Sensor Cleaning and Calibration
Folded Path Tunable Diode Laser Gas Analyzers

Recently uploaded (20)

PDF
737-MAX_SRG.pdf student reference guides
PDF
Well-logging-methods_new................
PDF
PPT on Performance Review to get promotions
PDF
III.4.1.2_The_Space_Environment.p pdffdf
PPTX
UNIT-1 - COAL BASED THERMAL POWER PLANTS
PPTX
bas. eng. economics group 4 presentation 1.pptx
PPTX
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
PDF
Unit I ESSENTIAL OF DIGITAL MARKETING.pdf
PPTX
Construction Project Organization Group 2.pptx
PDF
Enhancing Cyber Defense Against Zero-Day Attacks using Ensemble Neural Networks
PDF
TFEC-4-2020-Design-Guide-for-Timber-Roof-Trusses.pdf
DOCX
573137875-Attendance-Management-System-original
PPTX
Engineering Ethics, Safety and Environment [Autosaved] (1).pptx
PDF
Automation-in-Manufacturing-Chapter-Introduction.pdf
PDF
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
PPTX
Fundamentals of safety and accident prevention -final (1).pptx
PPTX
Internet of Things (IOT) - A guide to understanding
PDF
Mitigating Risks through Effective Management for Enhancing Organizational Pe...
DOCX
ASol_English-Language-Literature-Set-1-27-02-2023-converted.docx
PPTX
UNIT 4 Total Quality Management .pptx
737-MAX_SRG.pdf student reference guides
Well-logging-methods_new................
PPT on Performance Review to get promotions
III.4.1.2_The_Space_Environment.p pdffdf
UNIT-1 - COAL BASED THERMAL POWER PLANTS
bas. eng. economics group 4 presentation 1.pptx
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
Unit I ESSENTIAL OF DIGITAL MARKETING.pdf
Construction Project Organization Group 2.pptx
Enhancing Cyber Defense Against Zero-Day Attacks using Ensemble Neural Networks
TFEC-4-2020-Design-Guide-for-Timber-Roof-Trusses.pdf
573137875-Attendance-Management-System-original
Engineering Ethics, Safety and Environment [Autosaved] (1).pptx
Automation-in-Manufacturing-Chapter-Introduction.pdf
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
Fundamentals of safety and accident prevention -final (1).pptx
Internet of Things (IOT) - A guide to understanding
Mitigating Risks through Effective Management for Enhancing Organizational Pe...
ASol_English-Language-Literature-Set-1-27-02-2023-converted.docx
UNIT 4 Total Quality Management .pptx

Optimizing gas turbine performance with precise humidity measurements

  • 1. Optimizing gas turbine performance with precise humidity measurements Ensuring gas turbines run at maximum efficiency is a primary goal for operators. In the current economic climate, anything that increases productivity, and hence profit, is clearly welcome. From an environmental point of view, it is also important that turbines run as efficiently – and produce as few emissions – as possible. Fortunately, there are several ways to improve gas turbine output. Controlling the humidity and temperature of air entering the combustion inlet is one of the most important, as it has a direct effect on the turbine’s efficiency, emissions, and operational reliability. / APPLICATION NOTE Cooler, denser air increases output and efficiency In terms of gas turbine efficiency, the effect of air density is well known: denser intake air increases mass flow rate, which consequently results in improved turbine output and efficiency. Air density is inversely proportional to temperature, meaning that rising temperatures decrease air density and therefore reduce gas turbine efficiency and power. Inlet-air cooling, especially in warm and hot environments, is commonly used to compensate for the efficiency loss caused by high air temperature. Even a small reduction in air temperature can lead to a significant increase in power output. A 1°C reduction in air temperature can increase output by up to 0.5%. There are several techniques that are used to cool intake air. A common solution is a fogger, a system that injects water into the airflow through nozzles, causing the air to cool as the water droplets evaporate.
  • 2. A secondary benefit of fogging is that the increased humidity of the air reduces the NOx emissions produced by the combustion process. Apart from inlet-air cooling in warm or hot conditions, humidity can also be a critical factor in avoiding icing in cold climates. If humid air is close to freezing, anti-icing systems are needed to protect the compressor from the damage that fast-moving ice particles would cause. Optimal control needs accurate humidity information Given the high speed of air within the air inlet system, water droplets and ice particles must be prevented from entering the compressor and turbine to avoid costly damage and erosion. In practice, this means that the air humidity needs to be kept below saturation levels. In other words, to avoid condensation, the dew point temperature of the air entering the system has to be below the air and surface temperatures in the system. The control system has to have a safety margin to allow for measurement uncertainties as well as fluctuations and irregularities in the properties of the air being measured. However, the wider the margins that are needed due to measurement uncertainties, the greater the efficiency potential that is lost. This is where a high level of measurement reliability really pays off. Accurately measuring the dew point enables cooling and fogging, or even heating, to be performed as close as possible to the condensation or icing limit within the system. Different ways of expressing humidity Depending on the application, different terms are used to express humidity. These include, but are not limited to, relative humidity, dew point temperature, and wet bulb temperature. Relative humidity (RH) is the ratio of the water vapor’s partial pressure to its saturated pressure at a particular temperature. RH is expressed as a percentage and is generally used to describe ambient air humidity. The drawback of using RH is that it is heavily dependent on temperature. For example, if RH is 85% and the temperature 20°C, a decrease in the air temperature of only 2°C changes the RH to 96%. If RH is used to measure air humidity in a turbine inlet, this dependence has to be kept in mind because even without cooling or heating, the air temperature changes in the air inlet system. The main effect is cooling due to the acceleration of air at the compressor bell mouth, which can cause a temperature drop of several °C. Due to this cooling effect there is still a risk of ice formation even when the ambient temperature is above 0°C. A 1°C reduction in air temperature can increase output by up to 0.5%. Turbine output power can be increased with accurate inlet air humidity measurements.
  • 3. For more information, visit www.vaisala.com or contact us at sales@vaisala.com Ref. B211073EN EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. Products suitable for combustion inlet air monitoring: ▪ Vaisala HUMICAP® Humidity and Temperature Transmitter Series HMT330 and Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300. Both series have a heated probe option, chemical purge function, and Vaisala HUMICAP® thin-film polymer technology. ▪ To check functionality in the field, Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM70. ▪ To protect direct water splashes from entering the humidity sensor, Vaisala HUMICAP® Turbine Mounting Kit HMT300TMK. The dew point temperature (Td) is the temperature at which air, when cooled at constant pressure, becomes fully saturated with water vapor resulting in the formation of liquid water known as condensation. At 100% RH, the ambient temperature is the same as the dew point temperature, but when the dew point temperature is lower than the ambient temperature, the air becomes drier and therefore there is less risk of condensation forming. Two main benefits of using Td are that it is not temperature dependent and it directly provides the margin to condensing conditions. Wet bulb temperature (Tw) is the temperature indicated by a thermometer wrapped in a wet sheath. The wet bulb temperature and ambient temperature can be used to calculate relative humidity or the dew point. Tw is a traditional way to determine humidity but has largely been replaced by direct measurements as accuracy is limited and the method requires some skill to use and maintain. All the above humidity parameters are pressure dependent, but for air intake applications typical drops in pressure are so small that they do not have a significant effect. For example, at 20°C and 1013 mbar, a reduction in pressure of 20 mbar causes a reduction of 1.7% in RH or 0.3°C in Td. Factors affecting accuracy There are many factors that affect humidity measurement accuracy – basic sensing technology being the most obvious one. However thin-film polymer sensors have been proven to satisfy the most critical needs in inlet air monitoring: accuracy, robustness, long-term stability, and low maintenance requirements. Because air in the inlet may be very close to saturation, and perhaps even forming condensation, the sensor has to maintain accuracy even in these conditions. One challenge for a humidity sensor in condensing air is that if the sensor gets wet, the measurements will continue to show saturated conditions until the sensor dries – even though the air itself is no longer saturated. To overcome this problem, Vaisala has developed patented heating probe technology. This ensures that the temperature of the probe is kept above the surrounding air temperature in order to avoid condensation on the sensor itself. Depending on the system and exact installation position, direct water splashes may also wet the humidity sensor. Special mounting accessories are available to prevent this from happening. At power plants and polluted environments, the intake air may contain contaminants, which can affect long-term sensor accuracy. To overcome this challenge, advanced sensors can be configured with a chemical purge function, which cleans the sensor element automatically by evaporating possible contaminants.