SlideShare a Scribd company logo
50Hz
G E N S E T S E R I E S
A R I C H H E R I TA G E O F O V E R A C E N T U R Y O F
E N G I N E E R I N G E X C E L L E N C E .
Kirloskar power generating sets prioritize user experience, delivering exceptional
features and benefits. Streamlined installation and enhanced dependability to expedited service,
reduced maintenance costs, and optimized performance.
Kirloskar Powergen sets itself apart with groundbreaking engineering that
establishes new industry benchmarks.
Our state-of-the-art manufacturing facility embodies our commitment to sustainable practices.
We partner with nature to power the facility itself, transforming waste into valuable resources.
This focus on sustainability inspires both our workforce and surrounding communities.
It's here, where cutting-edge technology meets exceptional skills,
that we engineer solutions to empower limitless possibilities.
Discover our Plant with a
QR Code Scan.
POTENTIAL, SUSTAINABLE PRACTICES
50
HERTZ
T H E V E R S AT I L E P O W E R G E N E R AT O R S O L U T I O N
CONSTRUCTION
AGRICULTURE HEALTHCARE HOSPITALITY MANUFACTURING DATA CENTRES MINING REAL ESTATE
5 0 H z
D I E S E L G E N E R A T O R
Unmatched Features
Low Fuel Consumption
Reduced Emissions
Low Maintenance Cost
Easy Installation
500 Hours Service
Interval*
Extended Service
Intervals
Subject to usage of 15W40-CI4 grade oil
*Basis the applicable model and geography
F E A T U R E S
GENERATING SETS
Make
Model
Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Leroy Somer
S0L2F1 S0L2M1 S1L2J1 S1L2N1 UCI 224F1 UCI 224G1 UCI 274C1 UCI 274V1 / E1 UCI 274F1 UCI 274H1 UCI 274J1 / K1 HCI 444E1 HCI 444F1 HCI 544D1 HCI 544E1/F1 LSA49.1M75 LSA49.3L11
Leroy Somer
S1L2N1
No. of Bearings
Insulation
Single
Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H
Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single
Temp. Rise at Ambient 40°C 125
4
IP23
AS540
+/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1%
AS540 AS540 AS540 AS540 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 D350 D350
IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125
°C
Wires
Ingress Protection
AVR Model
Voltage Regulation %
ALTERNATOR (BRUSHLESS, SELF EXCITED, 4 POLE ALTERNATOR)
Model
Voltage
Standby
Power Output
Fuel Consumption
(at % of PRP)
Fuel Tank
Capacity
Open
SAE
17W50
17WS50
22W50
22WS50
33W50
33WS50
44W50-3
44SW50-3
44W50-4
44SW50-4
69W50
69WS50
91W50
91WS50
110W50
110WS50
L-L
L-N
V
V
380 380 380 380 380 380 380 380
400 400 400 400 400 400 400 400
415 415 415 415 415 415 415 415
220 220 220 220 220 220 220 220
230 230 230 230 230 230 230 230
240 240 240 240 240 240 240 240
ESP
PRP
kVA
kVA
kW
kW
16.5
15 20 30 40 40 62.5 82.5 100
22 33 44 44 69 91 110
13.2
12 16 24 32 32 50 66 80
17.6 26.4 35.2 35.2 55 72.6 88
Prime Power
Output
50%
75%
100%
L/Hr
L/Hr
L/Hr
2.0 2.6 3.7 5.1 5.1 7.6 9.7 10.7
2.7 3.6 5.1 6.9 6.9 10.8 13.8 17.7
3.4 4.7 6.7 9.1 9.1 14.4 18.3 22.5
Open
SAE
L
L
65 62 80 95 95 158 158 225
40 40 70 99 97 150 150 195
Sound Level at 7m
Dimensions (LxWxH)
(as per GA Drawing)
Dry Weight (net)
Approx.
SAE
Open
Open
dB (A)
cm
kg
70
141 x 104 x 133
650 700 790 840 840 1100 1200 1450
141 x 104 x 133 150 x 109 x 134 175 x 100 x 118 175 x 100 x 118 211 x 106 x 146 211 x 106 x 146 220 x 107 x 169
70 70 70 70 70 70 70
SAE
SAE
cm
kg
218 x 101 x 145
920 970 1100 1310 1310 1630 1950 2120
198 x 97 x 123 218 x 101 x 145 262 x 111 x 158 262x 111 x 158 297 x 116 x 166 297 x 116 x 166 327 x 116 x 193
138W50
138WS50
176W50
176WS50
220W50
220WS50
275W50
275WS50
352W50
352WS50
440W50
440WS50
550W50
550WS50
660W50
660WS50
825W50
825WS50
1111W50
1111WS50
380 380 380 380 380 380 380 380 380 380
400 400 400 400 400 400 400 400 400 400
415 415 415 415 415 415 415 415 415 415
220 220 220 220 220 220 220 220 220 220
230 230 230 230 230 230 230 230 230 230
240 240 240 240 240 240 240 240 240 240
125 160 200 250 320 400 500 600 750 1010
138 176 220 275 352 440 550 660 825 1111
100 128 160 200 256 320 400 480 600 808
110 140.8 176 220 281.6 352 440 528 660 888.8
15.5 19.1 24 29.8 40.5 46.4 61.2 70.7 83 120.6
20.7 25.0 31.9 41.9 55.3 61.6 75.6 92.7 115 161
26.8 34.0 42.3 55.1 70.8 80.4 97 123.7 152 208
230 275 340 350 552 552 680 900 880 410
195 270 325 325 560 560 870 930 1350 900
1510 1910 2320 2620 4250 4550 4750 5200 5880 8650
220 x 107 x 169 260 x 102 x 184 311 x 154 x 170 311 x 157 x 207 339 x 166 x 220 340 x 166 x 222 365 x 184 x 235 379 x 200 x 234 398 x 230 x 240 454 x 210 x 251
70 70 70 70 70 70 75 75 80 80
2180 2720 3440 3670 6000 6300 7100 7830 7850 13200
327 x 116 x 193 372 x 116 x 203 437 x 162 x 198 436 x 167 x 223 498 x 211 x 228 498 x 211 x 228 525 x 212 x 257 566 x 211 x 257 580 x 230 x 253 687 x 230 x 250
DI - Auto start digital input is available as standard feature • SD- Shutdown • SAE : Sound Attenuated Enclosure • ESP : Emergency Standby Power rating • PRP : Prime Rated Power rating • CT : Current Transformer •
LL : Line to Line • LN : Phase to Neutral • TC : Turbocharged • TA: Turbocharged Aftercooled • AVR : Automatic Voltage Regulator • MCB: Miniature Circuit Breaker • MCCB : Moulded Case Circuit Breaker
Definitions of Ratings as per ISO8528-1 - PRP - PRP ratings are applicable for supplying continuous electrical power at variable load in lieu of commercial purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload for 1 hour in 12 hours. ESP - ESP rating is defines as the maximum power available during a variable electrical power sequence, under the stated operating conditions,
for which a generating set is capable of delivering in the event of utility power outage. This rating is applicable for 200hours of operation per year with the maintenance intervals and procedures being carried out.
The permissible average power output over 24 hours of operation shall not exceed 70% of the ESP rating. No overload is permitted above ESP rating.
• For site conditions other than the standard reference conditions of ISO8528-1 the derating is applicable. Please contact nearest KOEL office for the available power calculation at given site conditions.
• The alternator models and controller models are of standard product and may vary as per the agreed scope.
• Alternator may vary basis on requirement
Model 2R1040 2R1040 3R1040 3R1040TA 4R1040 4R1040TC 4R1040TA 4K1080TA 6K1080TA 6SL1500TA 6SL8800TA DV8 DV10 DV12ETAG12 DV16ETAG1
4K1080TA DV8 DV12
Engine Output
Cycles and Configuration
Bore x Stoke
Compression Ratio
Starting System (DC)
Governor
Governor Class as per ISO8528-5
Lub Oil Sump Capacity - Refill
PRP hp 27
2 - Inline
105 x 120
18:1
2.08
12
Mechanical
G2
5.5 5.5 7.5 7.5 7.5 9.5 9.5 14 14 18 21 21 38 38 42 42 50 125
G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2
Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic
12 12 12 12 12 12 12 12 12 24 24 24 24 24 24 24 24
Natural Natural Natural TA Natural TC TA TA TA TA TA TA TA TA TA TA TA TA
2.08 3.12 3.12 3.12 4.16 4.16 4.32 4.32 6.48 8.86 8.86 15.91 15.91 19.9 23.88 23.88 31.88
18:1 18:1 18:1 18:1 18:1 18:1 15.5:1 15.5:1 15.5:1 17.5:1 17.5:1 16.5:1 16.5:1 16.5:1 16.5:1 16.5:1 16.5:1
105 x 120 105 x 120 105 x 120 105 x 120 105 x 120 105 x 120 105 x 125 105 x 125 105 x 125 118 x 135 118 x 135 130 x 150 130 x 150 130 x 150 130 x 150 130 x 150 130 x 150
27 42 56 56 83 105 156 156 200
6 - Inline
248 310 400
8 - V
490
8 - V
608
10 - V
750
12 - V
900
12 - V
1210
16 - V
2 - Inline 3 - Inline 3 - Inline 4 - Inline 4 - Inline 4 - Inline 4 - Inline 4 - Inline 6 - Inline 6 - Inline
mm
L
V
Displacement
Aspiration
L
Coolant Capacity 10
L
KIRLOSKAR ENGINE (LIQUID COOLED, 4 STROKE, DIESEL ENGINE)
10 12 12 12 24 24 54 54 54 43 43 123 123 133 144 166 180
• The declared weight and dimensions are approximate and for transportation purpose. Actual weight and dimensions are may vary as per the agreed scope. Mentioned height is without tail pipe.
• The declared fuel consumption is calculated values with 0.845 specific gravity of diesel as per BS 2869 class A2 and confirms to ISO 3046 and has production tolerance of +5%.
O P T I P R I M E G E N S E T T EC H N I CA L S P EC I F I CAT I O N
Notes
^ Tolerences Apply
# With 0.845 Specific Gravity of diesel (5% Tolerance)
$ These weight are for handling & transportation only,±5% tolerance apply
* Efficiency of Alternator as per standards IEC 60034-1
** For operation of outgoing breaker higher version of Synchronization controller is required
Prime Power at rated rpm PRP
kVA 2020
kW 1616
Stand by Power at rated ESP
kVA 2222
kW 1777.6
Voltage Voltage V 415
Frequency Hz 50Hz
Power factor 0.8 lagging
Noise level dB (A) @7metres 80
Fuel Consumption#
At 100% Load
L/Hr
402.8
At 75% Load 308.4
At 50% Load 215.4
At 25% Load 111.1
Fuel tank capacity (Standard DG set) Ltrs 860(430X2)
Weight of Genset with canopy (approx.) $
Dry Kg 25170
Wet Kg 26000
Overall dimensions of Genset^
Length mm 12192
Width mm 2438
Height (without silencer) mm 2895
Height (with silencer) mm 4002
Genset alignment/configuration Series
ENGINE Engine 1 Engine 2
Engine Model DV16 ETA DV16 ETA
Rated output (Prime Continuous rating as per ISO 8528
-1)
kW 889 889
hp 1210 1210
No. of cylinder Number 16 16
Bore x Stroke mm 130 x 150 130 x 150
RPM 1500 1500
Compression ratio 16.5:1 16.5:1
Cubic capacity2
Ltrs 31.84 31.84
Aspiration TA TA
Starting System V 24 24
Governor Electronic Electronic
Governing class as per ISO 8528-5 G2 G2
Lube Oil change period hrs. 500 500
Lube oil Sump Capacity per Engine Ltrs 130 130
Coolant Capacity per engine Ltrs 180 180
Block loading capacity % 55 55
ALTERNATOR Alternator 1 Alternator 2
Make Leroy Somer Leroy Somer
Model KG49.3 L11 KG49.3 L11
No. of bearings Single Single
Insulation Class Class H Class H
0
Temp. rise at ambient 40 C ° C 125 125
Wires 4 4
Ingress protection IP23 IP23
AVR model D350 D350
Alternator Efficiency (at 100% load) 0.8 pf* % 95.1 95.1
Voltage regulation +/-1% +/-1%
Max Voltage Dip at Full Load 0.8 pf Lag % <20% <20%
Max Time to build up rated voltage at Rated RPM Sec
< 2 sec provided en-
gine reach the rated
speed
< 2 sec provided en-
gine reach the rated
speed
Synchronization Panel
Incoming breaker STANDARD
Outgoing breaker Optional
Synchronization Controller** DSE8610 MKII
OPTIPRIME 2222WS50
Model 2222WS50
For Site Conditions other than standard operating
conditions consult Kirloskar Oil Engines Ltd.
For Site specific layout consult Kirloskar Oil Engines
Ltd to ammend the Genset alignment/configuration
CONTROL SYSTEM FEATURES AND SAFETIES
Controller Module
On Display Screen
Communication Ports
DSE4522 A2 DSE7320MKII
17W50, 22W50, 33W50, 44W50, 69W50,
91W50, 110W50, 138W50, 176W50
220W50, 275W50, 352W50, 440W50,
550W50, 660W50, 825W50, 1111W50
Model
17WS50, 22WS50, 33WS50, 44WS50, 69WS50,
91WS50, 110WS50, 138WS50, 176WS50
220WS50, 275WS50, 352WS50, 440WS50,
550WS50, 660WS50, 825WS50, 1111WS50.
2222WS50
Generating Set Volts, Amps. Hz
RS485
Generating Set Per Phase PF
Earth Current (A)
Battery Voltage (V)
Engine Temperature ( C)
Engine Run Hours (Hours & Min.)
Diesel Fuel Level (%)
Generating Set kW, kVA, kVAr
RS232
Generating Set kWHr Meter
Grid (Mains) Voltage (L-L)
Engine Start Attempts
Engine Speed (RPM)
Lube Oil Pressure (kPa, PSI, bar)
DSE4522 A2
DSE4522 A2
DSE7320MKII
DSE7320MKII
CUSTOMIZE YOUR POWER NEEDS WITH OPTIONAL ACCESSORIES
GENERATING SET ENGINE
External Bulk Fuel Tank of
1000L, 5000L, 10000L,
15000L
Fuel Transfer Pump
Fuel Priming Manual Pump
Fire Extinguisher
Cold Start Kit
Battery Isolator Switch
1000 Hours Service Interval Kit for Select Ratings
Jacket Water Heater 220V - 240V AC
Lube Oil Temperature Sensor
Y Y
Y Y
Y Y
Y Y
N Y
Y Y
Y Y
N Y
Y Y
Y Y
Y Y
Y Y
Y Y
Y Y
N Y
Y - Available N - Not Available
WR - Warning • SD - Shutdown • Ind - Indication • DI - Digital Input
CONTROL SYSTEM FEATURES AND SAFETIES
Controller Module DSE4522 A2 DSE7320MKII
WR SD Ind DI
Protection WR SD Ind DI
Low Oil Pressure
High Coolant Temperature
Low Fuel Level
Low Coolant Level
Under / Over Speed
Low / High Battery Voltage
Low Charge Alternator
Emergency Stop
Fail to Start/ Stop Warning
Auto Remote Start/stop DI
Under / Over Voltage
Under / Over Frequency
Over kW / Overcurrent
Low Load
Incorrect Phase Sequence
Reverse Power
Short Circuit
Earth Fault
CUSTOMIZE YOUR POWER NEEDS WITH OPTIONAL ACCESSORIES
ALTERNATOR CONTROLS
Alternator Space Heater
Permanent Magnet Exciter (PMG)
(For Select Ratings)
Alternator Inlet Louver Filters
Droop Current Transformer
(For Select Ratings)
Static Battery Charger 12V 5A / 24V 10A
ATS Panel
Dummy Load Bank
Remote Monitoring Unit
Synchronization Panel for Higher kVA Solutions
N Y
Y
Y Y Y
Y Y
Y
Y Y Y
Y Y
Y
Y N Y
N N
Y
Y Y Y
Y Y
Y
Y Y Y
Y Y
Y
N N Y
Y Y
Y
N N Y
Y
Y Y Y
Y Y
Y
N Y
Y Y
Y
Y Y Y
Y Y
Y
Y Y Y
N N
Y
Y Y Y
N Y
N
N Y Y
N N
N
N Y Y
N N
N
N Y Y
N N
N
N Y Y
N N
N
N Y Y
N
N
N
N
Y
Y
Y - Available N - Not Available Not Applicable
N N
N
E X T E R N A L F E A T U R E S
Emergency Stop Switch
Easily accessible on canopy
for stopping
Stainless Steel
Door Handles
High durability and
improved security
Top Lifting Arrangement
Easy to lift by crane
Mesh on Exhaust Tail Pipe
Prevents entry of pests /
rodents
Glass Window on Canopy
Easy to read generating set
parameters and safe
Door for
Radiator Access
External Fuel Tank
with Indicator Lamp
Ease of refuelling, prevents fuel
spillage and improves safety
Stainless Steel Door
Hinges
Heavy-duty, anti-corrosive
and long lasting
Provision of Gland Plate
Easy cable entry and improved safety
Pockets for Forklift
Facilitates easy handling and
installation
Easy access for faster service
Coolant Drain
Arrangement
Easy access for faster service
I N T E R N A L F E A T U R E S
Guard for Rotating and
Hot Parts
Increased safety
Heat Insulated Exhaust
Improves engine cooling
efficiency and serviceability
Lube Oil Drain Pump
Faster oil drain, reduces
downtime, eliminates need
of additional tray
Coolant Level Sensor
Supplementary engine
protection
Water Separator as a
Standard Feature
Prevents water entry into engine
Longer Fuel Tank Breather Tube
Prevents fuel spillage due to overfilling
Dual Fuel Gauge
Easy fuel level reading while re-fuelling
High Efficiency LED Lamp
Extra bright and low power consumption
SMF Batteries
I N G E N I O U S D E S I G N .
U N M AT C H E D P E R F O R M A N C E .
S H A P I N G T H E F U T U R E .
D E L I V E R I N G P O W E R T O O V E R 5 0 + C O U N T R I E S .
KIRLOSKAR OIL ENGINES LIMITED
A Kirloskar Group Company
Regd. Office: 13, Laxmanrao Kirloskar Road,
Khadki, Pune, Maharashtra 411 003
INDIA
IBG.X.022.REV0
Tel: +91 (20) 2581 0341
Fax: +91 (20) 2581 3208, 2581 0209
Helpline: +91 8806 33 44 33
koel.helpdesk@kirloskar.com
Marks ‘Kirloskar’ along with the suffix, or prefix, ‘I’ as shown and copyright ‘limitless’ are owned Kirloskar Proprietary Limited. and Kirloskar Oil Engines L td. is the Permitted User.
This Catalog is copyrighted and may not be reproduced in any form not even parts of it, without previous written permission by copyright owners, Kirloskar Oil Engines L td.
Product improvement is a continuous process. Kindly contact Kirloskar Oil Engines Ltd. for latest information.
Images are for illustration purposes only.

More Related Content

PDF
Shimpo able evb_brochure
PDF
Motor Technical Brochure for ABB LT Motors LT
PDF
Shimpo able evl_brochure
PDF
Fluid Power Actuators Dealers In India| YTC INDIA
PDF
Harmonic drive hdt t cup_specsheet
PDF
Harmonic shd 2uh_lw_catalog
PDF
WEG Contactors Oveload Relays
PDF
Harmonic csg gh_specsheet
Shimpo able evb_brochure
Motor Technical Brochure for ABB LT Motors LT
Shimpo able evl_brochure
Fluid Power Actuators Dealers In India| YTC INDIA
Harmonic drive hdt t cup_specsheet
Harmonic shd 2uh_lw_catalog
WEG Contactors Oveload Relays
Harmonic csg gh_specsheet

Similar to Petrol Gensets from Myspan Power - Portable and Efficient Power Solutions (20)

PDF
Cataloge ge 2.industrial components-1_record_plus
PDF
Cataloge ge 2.industrial components-1_record_plus
PDF
Cataloge ge 2.industrial components_dienhathe.com-1_record_plus
PDF
Harmonic drive quick connect_specshseet
PDF
Shimpo able vrl_brochure
PDF
Harmonic csf lw_specsheet
PDF
Harmonic drive csd specsheet
PDF
generator power selector to select engine
PDF
Shimpo able vrs_brochure
PDF
Shimpo able vrb_brochure
PDF
Delta ia mds-reg2000_c_en_20161124
PDF
Harmonic csf gh_specsheet
PDF
Harmonic hpgp specsheet
PDF
1 sbc100192c0201 main_catalog_motor_protection_and_control
PDF
Радиально-поршневые гидромоторы Hägglunds CA Bosch Rexroth
PDF
RK Engineering AF contactors_overload relays catalog_1SXU100109C0201.pdf
PDF
Harmonic hpn gearhead_catalog
PDF
Harmonic csg lw_spechseet
PDF
Shimpo able vral_catalog
Cataloge ge 2.industrial components-1_record_plus
Cataloge ge 2.industrial components-1_record_plus
Cataloge ge 2.industrial components_dienhathe.com-1_record_plus
Harmonic drive quick connect_specshseet
Shimpo able vrl_brochure
Harmonic csf lw_specsheet
Harmonic drive csd specsheet
generator power selector to select engine
Shimpo able vrs_brochure
Shimpo able vrb_brochure
Delta ia mds-reg2000_c_en_20161124
Harmonic csf gh_specsheet
Harmonic hpgp specsheet
1 sbc100192c0201 main_catalog_motor_protection_and_control
Радиально-поршневые гидромоторы Hägglunds CA Bosch Rexroth
RK Engineering AF contactors_overload relays catalog_1SXU100109C0201.pdf
Harmonic hpn gearhead_catalog
Harmonic csg lw_spechseet
Shimpo able vral_catalog
Ad

Recently uploaded (20)

PDF
BsN 7th Sem Course GridNNNNNNNN CCN.pdf
PDF
Module 2 - Modern Supervison Challenges - Student Resource.pdf
PDF
Charisse Litchman: A Maverick Making Neurological Care More Accessible
PDF
Solara Labs: Empowering Health through Innovative Nutraceutical Solutions
PDF
Laughter Yoga Basic Learning Workshop Manual
PDF
SBI Securities Weekly Wrap 08-08-2025_250808_205045.pdf
PDF
Ôn tập tiếng anh trong kinh doanh nâng cao
PDF
Digital Marketing & E-commerce Certificate Glossary.pdf.................
PPTX
ICG2025_ICG 6th steering committee 30-8-24.pptx
PDF
Family Law: The Role of Communication in Mediation (www.kiu.ac.ug)
PDF
How to Get Business Funding for Small Business Fast
PDF
Tata consultancy services case study shri Sharda college, basrur
PPTX
3. HISTORICAL PERSPECTIVE UNIIT 3^..pptx
PDF
How to Get Funding for Your Trucking Business
PDF
NEW - FEES STRUCTURES (01-july-2024).pdf
PPTX
DMT - Profile Brief About Business .pptx
PDF
NISM Series V-A MFD Workbook v December 2024.khhhjtgvwevoypdnew one must use ...
PDF
Daniels 2024 Inclusive, Sustainable Development
PDF
Nidhal Samdaie CV - International Business Consultant
PPTX
Sales & Distribution Management , LOGISTICS, Distribution, Sales Managers
BsN 7th Sem Course GridNNNNNNNN CCN.pdf
Module 2 - Modern Supervison Challenges - Student Resource.pdf
Charisse Litchman: A Maverick Making Neurological Care More Accessible
Solara Labs: Empowering Health through Innovative Nutraceutical Solutions
Laughter Yoga Basic Learning Workshop Manual
SBI Securities Weekly Wrap 08-08-2025_250808_205045.pdf
Ôn tập tiếng anh trong kinh doanh nâng cao
Digital Marketing & E-commerce Certificate Glossary.pdf.................
ICG2025_ICG 6th steering committee 30-8-24.pptx
Family Law: The Role of Communication in Mediation (www.kiu.ac.ug)
How to Get Business Funding for Small Business Fast
Tata consultancy services case study shri Sharda college, basrur
3. HISTORICAL PERSPECTIVE UNIIT 3^..pptx
How to Get Funding for Your Trucking Business
NEW - FEES STRUCTURES (01-july-2024).pdf
DMT - Profile Brief About Business .pptx
NISM Series V-A MFD Workbook v December 2024.khhhjtgvwevoypdnew one must use ...
Daniels 2024 Inclusive, Sustainable Development
Nidhal Samdaie CV - International Business Consultant
Sales & Distribution Management , LOGISTICS, Distribution, Sales Managers
Ad

Petrol Gensets from Myspan Power - Portable and Efficient Power Solutions

  • 1. 50Hz G E N S E T S E R I E S
  • 2. A R I C H H E R I TA G E O F O V E R A C E N T U R Y O F E N G I N E E R I N G E X C E L L E N C E . Kirloskar power generating sets prioritize user experience, delivering exceptional features and benefits. Streamlined installation and enhanced dependability to expedited service, reduced maintenance costs, and optimized performance. Kirloskar Powergen sets itself apart with groundbreaking engineering that establishes new industry benchmarks. Our state-of-the-art manufacturing facility embodies our commitment to sustainable practices. We partner with nature to power the facility itself, transforming waste into valuable resources. This focus on sustainability inspires both our workforce and surrounding communities. It's here, where cutting-edge technology meets exceptional skills, that we engineer solutions to empower limitless possibilities. Discover our Plant with a QR Code Scan. POTENTIAL, SUSTAINABLE PRACTICES
  • 3. 50 HERTZ T H E V E R S AT I L E P O W E R G E N E R AT O R S O L U T I O N CONSTRUCTION AGRICULTURE HEALTHCARE HOSPITALITY MANUFACTURING DATA CENTRES MINING REAL ESTATE 5 0 H z D I E S E L G E N E R A T O R
  • 4. Unmatched Features Low Fuel Consumption Reduced Emissions Low Maintenance Cost Easy Installation 500 Hours Service Interval* Extended Service Intervals Subject to usage of 15W40-CI4 grade oil *Basis the applicable model and geography F E A T U R E S
  • 5. GENERATING SETS Make Model Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Leroy Somer S0L2F1 S0L2M1 S1L2J1 S1L2N1 UCI 224F1 UCI 224G1 UCI 274C1 UCI 274V1 / E1 UCI 274F1 UCI 274H1 UCI 274J1 / K1 HCI 444E1 HCI 444F1 HCI 544D1 HCI 544E1/F1 LSA49.1M75 LSA49.3L11 Leroy Somer S1L2N1 No. of Bearings Insulation Single Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Temp. Rise at Ambient 40°C 125 4 IP23 AS540 +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% AS540 AS540 AS540 AS540 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 D350 D350 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 °C Wires Ingress Protection AVR Model Voltage Regulation % ALTERNATOR (BRUSHLESS, SELF EXCITED, 4 POLE ALTERNATOR) Model Voltage Standby Power Output Fuel Consumption (at % of PRP) Fuel Tank Capacity Open SAE 17W50 17WS50 22W50 22WS50 33W50 33WS50 44W50-3 44SW50-3 44W50-4 44SW50-4 69W50 69WS50 91W50 91WS50 110W50 110WS50 L-L L-N V V 380 380 380 380 380 380 380 380 400 400 400 400 400 400 400 400 415 415 415 415 415 415 415 415 220 220 220 220 220 220 220 220 230 230 230 230 230 230 230 230 240 240 240 240 240 240 240 240 ESP PRP kVA kVA kW kW 16.5 15 20 30 40 40 62.5 82.5 100 22 33 44 44 69 91 110 13.2 12 16 24 32 32 50 66 80 17.6 26.4 35.2 35.2 55 72.6 88 Prime Power Output 50% 75% 100% L/Hr L/Hr L/Hr 2.0 2.6 3.7 5.1 5.1 7.6 9.7 10.7 2.7 3.6 5.1 6.9 6.9 10.8 13.8 17.7 3.4 4.7 6.7 9.1 9.1 14.4 18.3 22.5 Open SAE L L 65 62 80 95 95 158 158 225 40 40 70 99 97 150 150 195 Sound Level at 7m Dimensions (LxWxH) (as per GA Drawing) Dry Weight (net) Approx. SAE Open Open dB (A) cm kg 70 141 x 104 x 133 650 700 790 840 840 1100 1200 1450 141 x 104 x 133 150 x 109 x 134 175 x 100 x 118 175 x 100 x 118 211 x 106 x 146 211 x 106 x 146 220 x 107 x 169 70 70 70 70 70 70 70 SAE SAE cm kg 218 x 101 x 145 920 970 1100 1310 1310 1630 1950 2120 198 x 97 x 123 218 x 101 x 145 262 x 111 x 158 262x 111 x 158 297 x 116 x 166 297 x 116 x 166 327 x 116 x 193 138W50 138WS50 176W50 176WS50 220W50 220WS50 275W50 275WS50 352W50 352WS50 440W50 440WS50 550W50 550WS50 660W50 660WS50 825W50 825WS50 1111W50 1111WS50 380 380 380 380 380 380 380 380 380 380 400 400 400 400 400 400 400 400 400 400 415 415 415 415 415 415 415 415 415 415 220 220 220 220 220 220 220 220 220 220 230 230 230 230 230 230 230 230 230 230 240 240 240 240 240 240 240 240 240 240 125 160 200 250 320 400 500 600 750 1010 138 176 220 275 352 440 550 660 825 1111 100 128 160 200 256 320 400 480 600 808 110 140.8 176 220 281.6 352 440 528 660 888.8 15.5 19.1 24 29.8 40.5 46.4 61.2 70.7 83 120.6 20.7 25.0 31.9 41.9 55.3 61.6 75.6 92.7 115 161 26.8 34.0 42.3 55.1 70.8 80.4 97 123.7 152 208 230 275 340 350 552 552 680 900 880 410 195 270 325 325 560 560 870 930 1350 900 1510 1910 2320 2620 4250 4550 4750 5200 5880 8650 220 x 107 x 169 260 x 102 x 184 311 x 154 x 170 311 x 157 x 207 339 x 166 x 220 340 x 166 x 222 365 x 184 x 235 379 x 200 x 234 398 x 230 x 240 454 x 210 x 251 70 70 70 70 70 70 75 75 80 80 2180 2720 3440 3670 6000 6300 7100 7830 7850 13200 327 x 116 x 193 372 x 116 x 203 437 x 162 x 198 436 x 167 x 223 498 x 211 x 228 498 x 211 x 228 525 x 212 x 257 566 x 211 x 257 580 x 230 x 253 687 x 230 x 250 DI - Auto start digital input is available as standard feature • SD- Shutdown • SAE : Sound Attenuated Enclosure • ESP : Emergency Standby Power rating • PRP : Prime Rated Power rating • CT : Current Transformer • LL : Line to Line • LN : Phase to Neutral • TC : Turbocharged • TA: Turbocharged Aftercooled • AVR : Automatic Voltage Regulator • MCB: Miniature Circuit Breaker • MCCB : Moulded Case Circuit Breaker Definitions of Ratings as per ISO8528-1 - PRP - PRP ratings are applicable for supplying continuous electrical power at variable load in lieu of commercial purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload for 1 hour in 12 hours. ESP - ESP rating is defines as the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of utility power outage. This rating is applicable for 200hours of operation per year with the maintenance intervals and procedures being carried out. The permissible average power output over 24 hours of operation shall not exceed 70% of the ESP rating. No overload is permitted above ESP rating. • For site conditions other than the standard reference conditions of ISO8528-1 the derating is applicable. Please contact nearest KOEL office for the available power calculation at given site conditions. • The alternator models and controller models are of standard product and may vary as per the agreed scope. • Alternator may vary basis on requirement Model 2R1040 2R1040 3R1040 3R1040TA 4R1040 4R1040TC 4R1040TA 4K1080TA 6K1080TA 6SL1500TA 6SL8800TA DV8 DV10 DV12ETAG12 DV16ETAG1 4K1080TA DV8 DV12 Engine Output Cycles and Configuration Bore x Stoke Compression Ratio Starting System (DC) Governor Governor Class as per ISO8528-5 Lub Oil Sump Capacity - Refill PRP hp 27 2 - Inline 105 x 120 18:1 2.08 12 Mechanical G2 5.5 5.5 7.5 7.5 7.5 9.5 9.5 14 14 18 21 21 38 38 42 42 50 125 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic 12 12 12 12 12 12 12 12 12 24 24 24 24 24 24 24 24 Natural Natural Natural TA Natural TC TA TA TA TA TA TA TA TA TA TA TA TA 2.08 3.12 3.12 3.12 4.16 4.16 4.32 4.32 6.48 8.86 8.86 15.91 15.91 19.9 23.88 23.88 31.88 18:1 18:1 18:1 18:1 18:1 18:1 15.5:1 15.5:1 15.5:1 17.5:1 17.5:1 16.5:1 16.5:1 16.5:1 16.5:1 16.5:1 16.5:1 105 x 120 105 x 120 105 x 120 105 x 120 105 x 120 105 x 120 105 x 125 105 x 125 105 x 125 118 x 135 118 x 135 130 x 150 130 x 150 130 x 150 130 x 150 130 x 150 130 x 150 27 42 56 56 83 105 156 156 200 6 - Inline 248 310 400 8 - V 490 8 - V 608 10 - V 750 12 - V 900 12 - V 1210 16 - V 2 - Inline 3 - Inline 3 - Inline 4 - Inline 4 - Inline 4 - Inline 4 - Inline 4 - Inline 6 - Inline 6 - Inline mm L V Displacement Aspiration L Coolant Capacity 10 L KIRLOSKAR ENGINE (LIQUID COOLED, 4 STROKE, DIESEL ENGINE) 10 12 12 12 24 24 54 54 54 43 43 123 123 133 144 166 180 • The declared weight and dimensions are approximate and for transportation purpose. Actual weight and dimensions are may vary as per the agreed scope. Mentioned height is without tail pipe. • The declared fuel consumption is calculated values with 0.845 specific gravity of diesel as per BS 2869 class A2 and confirms to ISO 3046 and has production tolerance of +5%.
  • 6. O P T I P R I M E G E N S E T T EC H N I CA L S P EC I F I CAT I O N Notes ^ Tolerences Apply # With 0.845 Specific Gravity of diesel (5% Tolerance) $ These weight are for handling & transportation only,±5% tolerance apply * Efficiency of Alternator as per standards IEC 60034-1 ** For operation of outgoing breaker higher version of Synchronization controller is required Prime Power at rated rpm PRP kVA 2020 kW 1616 Stand by Power at rated ESP kVA 2222 kW 1777.6 Voltage Voltage V 415 Frequency Hz 50Hz Power factor 0.8 lagging Noise level dB (A) @7metres 80 Fuel Consumption# At 100% Load L/Hr 402.8 At 75% Load 308.4 At 50% Load 215.4 At 25% Load 111.1 Fuel tank capacity (Standard DG set) Ltrs 860(430X2) Weight of Genset with canopy (approx.) $ Dry Kg 25170 Wet Kg 26000 Overall dimensions of Genset^ Length mm 12192 Width mm 2438 Height (without silencer) mm 2895 Height (with silencer) mm 4002 Genset alignment/configuration Series ENGINE Engine 1 Engine 2 Engine Model DV16 ETA DV16 ETA Rated output (Prime Continuous rating as per ISO 8528 -1) kW 889 889 hp 1210 1210 No. of cylinder Number 16 16 Bore x Stroke mm 130 x 150 130 x 150 RPM 1500 1500 Compression ratio 16.5:1 16.5:1 Cubic capacity2 Ltrs 31.84 31.84 Aspiration TA TA Starting System V 24 24 Governor Electronic Electronic Governing class as per ISO 8528-5 G2 G2 Lube Oil change period hrs. 500 500 Lube oil Sump Capacity per Engine Ltrs 130 130 Coolant Capacity per engine Ltrs 180 180 Block loading capacity % 55 55 ALTERNATOR Alternator 1 Alternator 2 Make Leroy Somer Leroy Somer Model KG49.3 L11 KG49.3 L11 No. of bearings Single Single Insulation Class Class H Class H 0 Temp. rise at ambient 40 C ° C 125 125 Wires 4 4 Ingress protection IP23 IP23 AVR model D350 D350 Alternator Efficiency (at 100% load) 0.8 pf* % 95.1 95.1 Voltage regulation +/-1% +/-1% Max Voltage Dip at Full Load 0.8 pf Lag % <20% <20% Max Time to build up rated voltage at Rated RPM Sec < 2 sec provided en- gine reach the rated speed < 2 sec provided en- gine reach the rated speed Synchronization Panel Incoming breaker STANDARD Outgoing breaker Optional Synchronization Controller** DSE8610 MKII OPTIPRIME 2222WS50 Model 2222WS50 For Site Conditions other than standard operating conditions consult Kirloskar Oil Engines Ltd. For Site specific layout consult Kirloskar Oil Engines Ltd to ammend the Genset alignment/configuration
  • 7. CONTROL SYSTEM FEATURES AND SAFETIES Controller Module On Display Screen Communication Ports DSE4522 A2 DSE7320MKII 17W50, 22W50, 33W50, 44W50, 69W50, 91W50, 110W50, 138W50, 176W50 220W50, 275W50, 352W50, 440W50, 550W50, 660W50, 825W50, 1111W50 Model 17WS50, 22WS50, 33WS50, 44WS50, 69WS50, 91WS50, 110WS50, 138WS50, 176WS50 220WS50, 275WS50, 352WS50, 440WS50, 550WS50, 660WS50, 825WS50, 1111WS50. 2222WS50 Generating Set Volts, Amps. Hz RS485 Generating Set Per Phase PF Earth Current (A) Battery Voltage (V) Engine Temperature ( C) Engine Run Hours (Hours & Min.) Diesel Fuel Level (%) Generating Set kW, kVA, kVAr RS232 Generating Set kWHr Meter Grid (Mains) Voltage (L-L) Engine Start Attempts Engine Speed (RPM) Lube Oil Pressure (kPa, PSI, bar) DSE4522 A2 DSE4522 A2 DSE7320MKII DSE7320MKII CUSTOMIZE YOUR POWER NEEDS WITH OPTIONAL ACCESSORIES GENERATING SET ENGINE External Bulk Fuel Tank of 1000L, 5000L, 10000L, 15000L Fuel Transfer Pump Fuel Priming Manual Pump Fire Extinguisher Cold Start Kit Battery Isolator Switch 1000 Hours Service Interval Kit for Select Ratings Jacket Water Heater 220V - 240V AC Lube Oil Temperature Sensor Y Y Y Y Y Y Y Y N Y Y Y Y Y N Y Y Y Y Y Y Y Y Y Y Y Y Y N Y Y - Available N - Not Available
  • 8. WR - Warning • SD - Shutdown • Ind - Indication • DI - Digital Input CONTROL SYSTEM FEATURES AND SAFETIES Controller Module DSE4522 A2 DSE7320MKII WR SD Ind DI Protection WR SD Ind DI Low Oil Pressure High Coolant Temperature Low Fuel Level Low Coolant Level Under / Over Speed Low / High Battery Voltage Low Charge Alternator Emergency Stop Fail to Start/ Stop Warning Auto Remote Start/stop DI Under / Over Voltage Under / Over Frequency Over kW / Overcurrent Low Load Incorrect Phase Sequence Reverse Power Short Circuit Earth Fault CUSTOMIZE YOUR POWER NEEDS WITH OPTIONAL ACCESSORIES ALTERNATOR CONTROLS Alternator Space Heater Permanent Magnet Exciter (PMG) (For Select Ratings) Alternator Inlet Louver Filters Droop Current Transformer (For Select Ratings) Static Battery Charger 12V 5A / 24V 10A ATS Panel Dummy Load Bank Remote Monitoring Unit Synchronization Panel for Higher kVA Solutions N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N Y N N Y Y Y Y Y Y Y Y Y Y Y Y Y N N Y Y Y Y N N Y Y Y Y Y Y Y Y N Y Y Y Y Y Y Y Y Y Y Y Y Y N N Y Y Y Y N Y N N Y Y N N N N Y Y N N N N Y Y N N N N Y Y N N N N Y Y N N N N Y Y Y - Available N - Not Available Not Applicable N N N
  • 9. E X T E R N A L F E A T U R E S Emergency Stop Switch Easily accessible on canopy for stopping Stainless Steel Door Handles High durability and improved security Top Lifting Arrangement Easy to lift by crane Mesh on Exhaust Tail Pipe Prevents entry of pests / rodents Glass Window on Canopy Easy to read generating set parameters and safe Door for Radiator Access External Fuel Tank with Indicator Lamp Ease of refuelling, prevents fuel spillage and improves safety Stainless Steel Door Hinges Heavy-duty, anti-corrosive and long lasting Provision of Gland Plate Easy cable entry and improved safety Pockets for Forklift Facilitates easy handling and installation Easy access for faster service Coolant Drain Arrangement Easy access for faster service
  • 10. I N T E R N A L F E A T U R E S Guard for Rotating and Hot Parts Increased safety Heat Insulated Exhaust Improves engine cooling efficiency and serviceability Lube Oil Drain Pump Faster oil drain, reduces downtime, eliminates need of additional tray Coolant Level Sensor Supplementary engine protection Water Separator as a Standard Feature Prevents water entry into engine Longer Fuel Tank Breather Tube Prevents fuel spillage due to overfilling Dual Fuel Gauge Easy fuel level reading while re-fuelling High Efficiency LED Lamp Extra bright and low power consumption SMF Batteries
  • 11. I N G E N I O U S D E S I G N . U N M AT C H E D P E R F O R M A N C E . S H A P I N G T H E F U T U R E . D E L I V E R I N G P O W E R T O O V E R 5 0 + C O U N T R I E S . KIRLOSKAR OIL ENGINES LIMITED A Kirloskar Group Company Regd. Office: 13, Laxmanrao Kirloskar Road, Khadki, Pune, Maharashtra 411 003 INDIA IBG.X.022.REV0 Tel: +91 (20) 2581 0341 Fax: +91 (20) 2581 3208, 2581 0209 Helpline: +91 8806 33 44 33 koel.helpdesk@kirloskar.com Marks ‘Kirloskar’ along with the suffix, or prefix, ‘I’ as shown and copyright ‘limitless’ are owned Kirloskar Proprietary Limited. and Kirloskar Oil Engines L td. is the Permitted User. This Catalog is copyrighted and may not be reproduced in any form not even parts of it, without previous written permission by copyright owners, Kirloskar Oil Engines L td. Product improvement is a continuous process. Kindly contact Kirloskar Oil Engines Ltd. for latest information. Images are for illustration purposes only.