 Electrical substation consists of a number of
incoming circuits and outgoing circuits
connected to common busbar system. Busbars
are conducting bars to which a number of
incoming or outgoing circuits are connected.
 A substation receives electrical power from
generating station via incoming transmission
lines and delivers electrical power via the
outgoing transmission lines.
powergrid presentation
 A transformer is an electrical device that transfers
electrical energy between two or more circuits through
electromagnetic induction. Commonly, transformers are
used to increase or decrease the voltages of alternating
current in electric power applications.
 Transformer is a static machine, which transforms the
potential of alternating current at same frequency.
 This substation has two types of transformer:-
-Two 165MVA 220/132kV transformers
- One 315MVA 400/220kV transformer
 Cooling fans are used for forced air
cooling of the transformer
 165 MVA uses six cooling fans
 315 MVA uses eight cooling fans
 All fans not start at the same time.
They start in pairs.
 In electrical engineering, a current
transformer(CT) is used for measurements of
electric currents.Current transformers, together
with voltage transformers(VT)(potential
transformers(PT)), are known as instrument
transformers.
 When current in a circuit is too high to directly
apply measuring instruments, a current
transformer produces a reduced current
accurately proportional to the current in the
circuit,which can be conveniently connected to
the measuring and the recording element.
 A capacitor voltage transformer (CVT) is a transformer
used in power systems to step-down extra high voltage
signals and provide low voltage signals either for
measurement or to operate a protective relay.
 In its most basic form the device consists of three
parts: two capacitors across which the voltage signal is
split, an inductive element used to tune the device to
the supply frequency and a transformer used to isolate
and further step-down the voltage for the
instrumentation or protective relay.
 A circuit is a automatically operate switch designed to protect the system during shortcircuit
or abnormal conditions.
 Below shown is of SF6 circuit breaker.
 In electrical engineering, a
disconnector, disconnect switch
or isolator switch[1] is used to
ensure that an electrical circuit is
completely de-energized for
service or maintenance.
 Such switches are often found in
electrical distribution and
industrial applications, where
machinery must have its source of
driving power removed for
adjustment or repair.
 Surges, or transients, are brief
overvoltage spikes or disturbances on a
power waveform that can damage,
degrade, or destroy electronic
equipment within any home,
commercial building, industrial, or
manufacturing facility.
 The overvoltage protection is obtained
by the use of lightning/surge arresters.
 Lightning Arresters or Surge Arresters
are always connected in shunt to the
equipment to be protected, they provide
a low impedance path for the surge
current to the ground.
 Mostly in present days zinc oxide(Zno)
gapless arresters are in use
 In electrical engineering, a protective relay is
a device designed to trip a circuit breaker
when a fault is detected.
 The first protective relays were
electromagnetic devices, relying on coils
operating on moving parts to provide
detection of abnormal operating conditions
such as over-current, over-voltage, reverse
power flow, over- and under- frequency.
 Microprocessor-based digital protection
relays now emulate the original devices, as
well as providing types of protection and
supervision impractical with
electromechanical relays
 Wave trap are used for carrier
communication.
 It traps the higher frequency
above 50 Hz.
 It is the effort to utilize the
same transmission line
between to substation for the
purpose of communication
powergrid presentation
 The control panels and relays of
the substation require DC
supply of 220V.This DC supply
is made with the help of battery
bank reserve normally kept in a
separate room called Battery
room.
 The batteries used in this
substation are Nickel-Cadmium
(Ni-Cd) batteries.
 The control room has various control panels which shows the
information like incoming power, outgoing power, frequency,
time common to all substations, status of various lines
(healthy, faulted, under outage or maintenance), status of
various protective instruments like isolators, circuit breakers;
temperatures of various instruments, working tap of
transformers etc.
 The relay room is separate from the control room. All relays
used here are numerical and are either from Siemen ”OR
ABB”.
 The protection system is so fast that it can detect a fault within
30 ms and hence the circuit breaker can be operated within as
less as 80 ms. For 400 kV side C.B.
powergrid presentation
powergrid presentation

More Related Content

PPTX
Design of substation
PPTX
PPT on 33/11 sub-station uppcl
PPTX
132KV SUBSTATION UPPTCL
DOCX
Electrical substations: 132 KV
PPTX
Visit to 400 kV substation, Hadala
PDF
220KV Substation Training Report
PPTX
132kV GSS ppt
Design of substation
PPT on 33/11 sub-station uppcl
132KV SUBSTATION UPPTCL
Electrical substations: 132 KV
Visit to 400 kV substation, Hadala
220KV Substation Training Report
132kV GSS ppt

What's hot (20)

PPTX
SUBSTATION OVERVIEW - A presentation on substation
PPTX
PPT ON 33/11KV SUBSTATION
DOCX
Report on industrial summer training on 220 kv substation
PPTX
ppt on summer training on uppcl
PPTX
400kv sub-station-final-ppt-by-mohit
PDF
Switchyard design overview
PPT
132kv Substation
PPTX
1.substation layouts
DOCX
substation internship report
PPT
Substation overview
PPTX
PPT ON SUMMER TRAINING FROM UPPCL 132/33 KV SUB STATION
PDF
Transformer protection
PDF
Report on 220kv substation at Jassure
PPTX
Presentation on 132/33 KVSubstation Training
PPTX
Substation protection devices
PPTX
220 kv gss dausa
PPTX
Ppt of 132kv gss sitapura jaipur
PPTX
Ppt of ehv ac transmission
PDF
Power Transmission & Distribution in India
PPTX
Switchgear and protection 1
SUBSTATION OVERVIEW - A presentation on substation
PPT ON 33/11KV SUBSTATION
Report on industrial summer training on 220 kv substation
ppt on summer training on uppcl
400kv sub-station-final-ppt-by-mohit
Switchyard design overview
132kv Substation
1.substation layouts
substation internship report
Substation overview
PPT ON SUMMER TRAINING FROM UPPCL 132/33 KV SUB STATION
Transformer protection
Report on 220kv substation at Jassure
Presentation on 132/33 KVSubstation Training
Substation protection devices
220 kv gss dausa
Ppt of 132kv gss sitapura jaipur
Ppt of ehv ac transmission
Power Transmission & Distribution in India
Switchgear and protection 1
Ad

Viewers also liked (20)

PPTX
WhatsApp
PDF
CaseStudies
PPTX
A global progressive tax on wealth
DOCX
Lawrence J Carder LinkedIn
PDF
Correccion del examen
PDF
LA REACTION DES INTELLECTUELS
PPTX
5 Steps For Storing Your Dust Collection Equipment Long-Term
PPTX
441 presentation 4
PPTX
Evaluation
PDF
Fencon Godie Contract (CoW)
PPTX
Germany Presentation on Quality
PPTX
Final presentation
DOCX
CURRICULUM VITAE
PDF
LES ANNEES 1960 EN FRANCE ET EN ITALIE
PPTX
diagrama de depliegue
DOCX
Mis escrituras 1
DOCX
Proyecto de expresion oral
DOCX
Albuhaisi, osama cipm-2016
WhatsApp
CaseStudies
A global progressive tax on wealth
Lawrence J Carder LinkedIn
Correccion del examen
LA REACTION DES INTELLECTUELS
5 Steps For Storing Your Dust Collection Equipment Long-Term
441 presentation 4
Evaluation
Fencon Godie Contract (CoW)
Germany Presentation on Quality
Final presentation
CURRICULUM VITAE
LES ANNEES 1960 EN FRANCE ET EN ITALIE
diagrama de depliegue
Mis escrituras 1
Proyecto de expresion oral
Albuhaisi, osama cipm-2016
Ad

Similar to powergrid presentation (20)

PPTX
Madan mohan malaviya
PPTX
PRESENTATION ON UPPTCL 220 KV TRANSMISSION SUMMER TRAINING BANDA, BANDA FROM ...
PPTX
220 kv gss sitapua ppt sk95
PPTX
Indusrtrial training ppt (1).pptx
PPTX
PPT FINAL YEAR PRESENTATION ON SUBSTATION PROTECTION .pptx
PPTX
Uttar Pradesh Power Corporation 132kv
PPTX
400 KV GSS HEERAPURA, JAIPUR
PPTX
Ashish.pptx
PPTX
Cspdcl microsoft power point presentation
PPTX
132 KV Substation Gajraula.pptx
PPTX
Anurag Attri.pptx
PPTX
sub subsation seminar ppt.pptx
PPTX
Presentation 2014
PPTX
rough.pptx
PPTX
220 kV GSS Mansarovar Jaipur (RVPNL) Training PPT SM54
PPTX
Industrial training is an important in industry
PPTX
132 kV uppcl
PDF
PDFen (1).pdf
PPTX
Assam Electricity Grid Corporation PRESENTATION.pptx
Madan mohan malaviya
PRESENTATION ON UPPTCL 220 KV TRANSMISSION SUMMER TRAINING BANDA, BANDA FROM ...
220 kv gss sitapua ppt sk95
Indusrtrial training ppt (1).pptx
PPT FINAL YEAR PRESENTATION ON SUBSTATION PROTECTION .pptx
Uttar Pradesh Power Corporation 132kv
400 KV GSS HEERAPURA, JAIPUR
Ashish.pptx
Cspdcl microsoft power point presentation
132 KV Substation Gajraula.pptx
Anurag Attri.pptx
sub subsation seminar ppt.pptx
Presentation 2014
rough.pptx
220 kV GSS Mansarovar Jaipur (RVPNL) Training PPT SM54
Industrial training is an important in industry
132 kV uppcl
PDFen (1).pdf
Assam Electricity Grid Corporation PRESENTATION.pptx

powergrid presentation

  • 1. Industrial Trainingat Power gridcorporationof indialimited (A Government of India Enterprises) Presented By- Akriti Gupta Electronics and Communication Engg. 7th Sem 1409131905
  • 2.  Electrical substation consists of a number of incoming circuits and outgoing circuits connected to common busbar system. Busbars are conducting bars to which a number of incoming or outgoing circuits are connected.  A substation receives electrical power from generating station via incoming transmission lines and delivers electrical power via the outgoing transmission lines.
  • 4.  A transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction. Commonly, transformers are used to increase or decrease the voltages of alternating current in electric power applications.  Transformer is a static machine, which transforms the potential of alternating current at same frequency.  This substation has two types of transformer:- -Two 165MVA 220/132kV transformers - One 315MVA 400/220kV transformer
  • 5.  Cooling fans are used for forced air cooling of the transformer  165 MVA uses six cooling fans  315 MVA uses eight cooling fans  All fans not start at the same time. They start in pairs.
  • 6.  In electrical engineering, a current transformer(CT) is used for measurements of electric currents.Current transformers, together with voltage transformers(VT)(potential transformers(PT)), are known as instrument transformers.  When current in a circuit is too high to directly apply measuring instruments, a current transformer produces a reduced current accurately proportional to the current in the circuit,which can be conveniently connected to the measuring and the recording element.
  • 7.  A capacitor voltage transformer (CVT) is a transformer used in power systems to step-down extra high voltage signals and provide low voltage signals either for measurement or to operate a protective relay.  In its most basic form the device consists of three parts: two capacitors across which the voltage signal is split, an inductive element used to tune the device to the supply frequency and a transformer used to isolate and further step-down the voltage for the instrumentation or protective relay.
  • 8.  A circuit is a automatically operate switch designed to protect the system during shortcircuit or abnormal conditions.  Below shown is of SF6 circuit breaker.
  • 9.  In electrical engineering, a disconnector, disconnect switch or isolator switch[1] is used to ensure that an electrical circuit is completely de-energized for service or maintenance.  Such switches are often found in electrical distribution and industrial applications, where machinery must have its source of driving power removed for adjustment or repair.
  • 10.  Surges, or transients, are brief overvoltage spikes or disturbances on a power waveform that can damage, degrade, or destroy electronic equipment within any home, commercial building, industrial, or manufacturing facility.  The overvoltage protection is obtained by the use of lightning/surge arresters.  Lightning Arresters or Surge Arresters are always connected in shunt to the equipment to be protected, they provide a low impedance path for the surge current to the ground.  Mostly in present days zinc oxide(Zno) gapless arresters are in use
  • 11.  In electrical engineering, a protective relay is a device designed to trip a circuit breaker when a fault is detected.  The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, over-voltage, reverse power flow, over- and under- frequency.  Microprocessor-based digital protection relays now emulate the original devices, as well as providing types of protection and supervision impractical with electromechanical relays
  • 12.  Wave trap are used for carrier communication.  It traps the higher frequency above 50 Hz.  It is the effort to utilize the same transmission line between to substation for the purpose of communication
  • 14.  The control panels and relays of the substation require DC supply of 220V.This DC supply is made with the help of battery bank reserve normally kept in a separate room called Battery room.  The batteries used in this substation are Nickel-Cadmium (Ni-Cd) batteries.
  • 15.  The control room has various control panels which shows the information like incoming power, outgoing power, frequency, time common to all substations, status of various lines (healthy, faulted, under outage or maintenance), status of various protective instruments like isolators, circuit breakers; temperatures of various instruments, working tap of transformers etc.  The relay room is separate from the control room. All relays used here are numerical and are either from Siemen ”OR ABB”.  The protection system is so fast that it can detect a fault within 30 ms and hence the circuit breaker can be operated within as less as 80 ms. For 400 kV side C.B.