3 What is RAID?
4 RAID Levels
5 Evaluation Criteria for the RAID Levels
6 RAID 0 or Striping
7 RAID 1 or Mirroring
8 RAID 0+1 (1)
9 RAID 0+1 (2)
10 RAID 3 (1)
11 RAID 3 (2)
12 RAID 5 (1)
13 RAID 5 (2)
14 Adaptive RAID 3+5
15 RAID 6
16 Further Aspects for High Availability
17 Performance Optimization Features
Betriebssysteme Einführung 3 Chr. Vogt
What is RAID?
RAID (Redundant Array of Independent Disks)
was first defined by Patterson, Gibson, and Katz from the Berkeley University in 1987,
uses logical volumes consisting of several disks.
The RAID level defines how the disks are organized,
Depending on the RAID level, the reliability and/or the performance will be improved.
RAID systems can be implemented
in software
in hardware
RAID controllers
external RAID subsystems
RAID functionality offered by the storage arrays in a SAN (Storage Area Network)
Betriebssysteme Einführung 4 Chr. Vogt
RAID Levels
Originally, five RAID levels were defined:
RAID 1: Mirrored disks
RAID 2: Hamming code for error detection
RAID 3: Single parity disk, bit-interleaved parity
RAID 4: Single parity disk, block-level parity
RAID 5: Spread data/parity over all disks (block-level distributed parity)
Later, further RAID levels were defined:
RAID 0: Striped disks (no redundancy)
RAID 0+1: a combination of RAID 0 and RAID 1
RAID 6: dual redundancy using a Reed-Solomon code
Only RAID 0, RAID 1, RAID 0+1, and RAID 5 are commonly used today
(occasionally also RAID 3, and RAID 6).
Betriebssysteme Einführung 5 Chr. Vogt
Evaluation Criteria for the RAID Levels
The following aspects need to be considered when evaluating the different RAID levels:
Space efficiency / cost: How much additional disk space is required for redundant data?
Reliability: How many disks may fail without losing data?
Also: What reliability remains after a disk failure?
Performance:
during normal operation,
after a disk failure,
during the restoration of a failed disk.
In many cases
read and write operations have to be considered separately,
the performance also depends on the size of the I/O.
Restoration: What needs to be done in order to restore the data of a failed disk.
Betriebssysteme Einführung 6 Chr. Vogt
RAID 0 or Striping
For a RAID 0 array with n disks, data is divided into n strips which are written to the
disks in a round-robin fashion.
Space efficiency / cost: No redundancy, 100% storage efficiency, no extra cost.
Reliability: No redundancy, no reliability.
Performance: Very good, when the disks can work in parallel.
Depends on the stripe size, the I/O size, and on the number of
simultaneous requests.
Betriebssysteme Einführung 7 Chr. Vogt
RAID 1 or Mirroring
The same data is written to two or more disks.
Space efficiency / cost: 1/n for an n-fold mirror / n times as many disks are needed
Reliability: n-1 disks can fail without losing data
Performance: Read performance is improved: read from any disk (in parallel)
Write performance is unchanged: parallel writes to all disks
Restoration: Copy the data from a remaining disk in the mirror set
Betriebssysteme Einführung 8 Chr. Vogt
RAID 0+1 (1)
RAID 0+1 is sometimes also called RAID 10. It can be built in two different ways:
Space efficiency / cost: 1/n when using n-fold mirrors / n times as many disks are needed
Performance: As with RAID 0
Mirrored Stripesets Striped Mirrorsets
Betriebssysteme Einführung 9 Chr. Vogt
RAID 0+1 (2)
Reliability:
Mirrored Stripesets: Any n-1 disks can fail without losing data (n-fold mirroring).
A failing disk makes the whole stripe set inaccessible.
Striped Mirrorsets: Any n-1 disks can fail without losing data (n-fold mirroring).
n-1 disks can fail per mirror set in the stripe set.
Restoration (of a single failed disk):
Mirrored Stripesets: A whole stripeset needs to be copied from one of the remaining
copies in the mirrorset.
Striped Mirrorsets: The data on the failed disk needs to be copied from one of the
remaining disks in the mirrorset.
RAID 0+1
should always be built as striped mirrorsets,
is the best possible solution when cost is not the main concern.
Betriebssysteme Einführung 10 Chr. Vogt
RAID 3 (1)
For a RAID 3 array with n disks, data
is divided into n-1 strips (typically small ones),
parity information (bitwise XOR) is calculated over the n-1 strips and stored on the n-th disk.
Space efficiency / cost: (n-1)/n when using n disks / 1 additional parity disk is needed
Reliability: 1 disk may fail without losing data
Betriebssysteme Einführung 11 Chr. Vogt
RAID 3 (2)
Performance:
Normal operation:
Good read performance (disks are accessed in parallel).
Good write performance for large I/O requests (more than n-1 strips), because all disks are
accessed in parallel.
Very bad performance for small writes which access only one or few disks:
read the old data from the disks, which will not be overwritten,
calculate the new parity,
write the new data and the new parity.
After a disk failure: Performance decreases, because the missing data must be
restored from the old data and the parity information.
In either situation, the single parity disk can become a bottleneck.
Restoration: In order to restore the contents of a failed disk, all remaining disks,
including the parity disk, must be read. Hence, there will be a heavy
I/O load on the disks during the restoration.
Betriebssysteme Einführung 12 Chr. Vogt
RAID 5 (1)
For a RAID 5 array with n disks, data
is divided into n-1 strips (typically large ones),
parity information (bitwise XOR) is calculated over the n-1 strips,
the parity information is distributed over the disks.
Space efficiency / cost: (n-1)/n when using n disks / 1 additional disk is needed
Reliability: 1 disk may fail without losing data
Betriebssysteme Einführung 13 Chr. Vogt
RAID 5 (2)
Performance:
Normal operation:
Good read performance (disks are accessed in parallel).
Because of the big stripe size, I/Os typically only access one or few disks.
Very bad performance for small writes:
read the old data that is to be changed and the old parity information,
calculate the new parity (from the old data, the old parity, and the new data),
write the new data and the new parity.
After a disk failure: Performance decreases, because the missing data must be
restored from the old data and the parity information.
Restoration: In order to restore the contents of a failed disk, all remaining disks,
including the parity disk, must be read. Hence, there will be a heavy
I/O load on the disks during the restoration.
(Same as with RAID 3.)
Betriebssysteme Einführung 14 Chr. Vogt
Adaptive RAID 3+5
Some vendors claim that their RAID systems (software or hardware) perform adaptive
RAID 3 / RAID 5 operations.
The placement of the parity information is fixed, and cannot be changed dynamically.
The adaptation lies in the choice of the write algorithm, depending on the I/O size:
perform large I/Os by writing all data and the parity in parallel,
perform small I/Os by using the algorithm described for RAID 5.
Betriebssysteme Einführung 15 Chr. Vogt
RAID 6
For a RAID 6 array with n disks, data
is divided into n-2 strips,
two pieces of parity information are calculated over the n-2 strips (using a Reed-Solomon code),
the parity information is distributed over the disks.
Space efficiency / cost: (n-2)/n when using n disks / 2 additional disks are needed
Reliability: 2 disks may fail without losing data.
Performance and Restoration: Similar to RAID 5.
Betriebssysteme Einführung 16 Chr. Vogt
Further Aspects for High Availability
RAID sets protect against the loss of data in case of a disk failure.
In addition, provisions need to be taken to
make the access to the data highly available,
improve the performance of I/O operations.
In order to make data access highly available, a RAID system should provide
redundant power supplies, fans, etc.
several busses for attaching the disks,
redundant controllers
with load balancing for the I/O requests,
with cache takeover in case of a controller failure,
hot-swappable components (disks, power supplies, etc.),
hot spare disks to reduce the time during which a disk is missing from a RAID set.
Betriebssysteme Einführung 17 Chr. Vogt
Performance Optimization Features
Caches, which can in particular improve the bad write performance of RAID3 and RAID5 sets.
To avoid data inconsistencies („write hole“), caches must be protected with a battery backup.
Load balancing between redundant controllers.
In mirrorsets,
read from the disk with the optimal head position, and/or
load balance the read requests between the disks in the mirrorset.
Since I/O performance often depends on the size of the I/Os, a RAID system should
gather statistical information about the I/O sizes,
allow the stripe size (or: chunk size) to be adjusted for each RAID set individually.
Since restoring a failed disk causes a heavy additional I/O load, it should be possible to
decide whether to give preference to
the restore operation, in order to restore redundancy as quickly as possible,
the application I/Os, in order to affect the applications as little as possible.

More Related Content

PDF
DBMS Unit IV and V Material
PPT
Raid_intro.ppt
PPTX
RAID: High-Performance, Reliable Secondary Storage
PPTX
SEMINAR
PPT
Raid Level
PDF
Sistemas operacionais raid
DBMS Unit IV and V Material
Raid_intro.ppt
RAID: High-Performance, Reliable Secondary Storage
SEMINAR
Raid Level
Sistemas operacionais raid

What's hot (20)

PPTX
PPTX
RAID LEVELS
DOCX
Mass storage structurefinal
PPTX
PPTX
Raid levels
PPT
Disk structure
PPT
Raid : Redundant Array of Inexpensive Disks
PPTX
RAIDZ on-disk format vs. small blocks
PDF
Raid data recovery Tips
PPTX
Storage Devices And Backup Media
PPT
Raid+controllers
PPTX
Coal presentationt
PPTX
Raid in SNA
PDF
Mass Storage Devices
PPT
Demystifying Storage
PPTX
Massstorage
PPTX
Mass storage device
PPTX
Mass storage systemsos
PPTX
Raid technology
PPTX
Less is More: 2X Storage Efficiency with HDFS Erasure Coding
RAID LEVELS
Mass storage structurefinal
Raid levels
Disk structure
Raid : Redundant Array of Inexpensive Disks
RAIDZ on-disk format vs. small blocks
Raid data recovery Tips
Storage Devices And Backup Media
Raid+controllers
Coal presentationt
Raid in SNA
Mass Storage Devices
Demystifying Storage
Massstorage
Mass storage device
Mass storage systemsos
Raid technology
Less is More: 2X Storage Efficiency with HDFS Erasure Coding
Ad

Similar to Raid (20)

PPTX
RveewvewvwevevwvwvwevwevwevweveeAID.pptx
PPT
Unit 6 Device management.ppt Unit 6 Device management.ppt
PPTX
presentasi-raid-server-cloud-computing.pptx
PPTX
Raid(Storage Technology)
PPTX
Data center core elements, Data center virtualization
PPTX
PPT
RAID CONCEPT
PPT
disk structure and multiple RAID levels .ppt
DOCX
Various raid levels pros & cons
PDF
RAID--16112022-093218am-16022024-061222pm.pdf
PPTX
RAID - (Redundant Array of Inexpensive Disks or Drives, or Redundant Array of...
PDF
Raid_structure_os[1].pdfhdgretrhfgfhfhyt
PPTX
Raid structure os.pptxmbj;fdjhlljtzejtjdfi
PDF
Raid training
PDF
DOCX
Raid (Redundant Array of Inexpensive Disks) in Computer Architecture
PPT
RAID.ppt
PDF
unitV_part2.pdfj hjjjjjjjjjjjjjjjjjjjjjjjjj
RveewvewvwevevwvwvwevwevwevweveeAID.pptx
Unit 6 Device management.ppt Unit 6 Device management.ppt
presentasi-raid-server-cloud-computing.pptx
Raid(Storage Technology)
Data center core elements, Data center virtualization
RAID CONCEPT
disk structure and multiple RAID levels .ppt
Various raid levels pros & cons
RAID--16112022-093218am-16022024-061222pm.pdf
RAID - (Redundant Array of Inexpensive Disks or Drives, or Redundant Array of...
Raid_structure_os[1].pdfhdgretrhfgfhfhyt
Raid structure os.pptxmbj;fdjhlljtzejtjdfi
Raid training
Raid (Redundant Array of Inexpensive Disks) in Computer Architecture
RAID.ppt
unitV_part2.pdfj hjjjjjjjjjjjjjjjjjjjjjjjjj
Ad

Recently uploaded (20)

PPTX
Digital-Transformation-Roadmap-for-Companies.pptx
PDF
NewMind AI Weekly Chronicles - August'25 Week I
PDF
Per capita expenditure prediction using model stacking based on satellite ima...
PDF
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
PPTX
Effective Security Operations Center (SOC) A Modern, Strategic, and Threat-In...
PDF
Empathic Computing: Creating Shared Understanding
PPTX
Big Data Technologies - Introduction.pptx
PPT
“AI and Expert System Decision Support & Business Intelligence Systems”
PDF
Chapter 3 Spatial Domain Image Processing.pdf
PPTX
Spectroscopy.pptx food analysis technology
PDF
Advanced methodologies resolving dimensionality complications for autism neur...
PDF
Network Security Unit 5.pdf for BCA BBA.
PDF
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
PDF
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
PDF
Reach Out and Touch Someone: Haptics and Empathic Computing
PDF
Encapsulation_ Review paper, used for researhc scholars
PDF
Unlocking AI with Model Context Protocol (MCP)
PDF
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
PPTX
Programs and apps: productivity, graphics, security and other tools
PPT
Teaching material agriculture food technology
Digital-Transformation-Roadmap-for-Companies.pptx
NewMind AI Weekly Chronicles - August'25 Week I
Per capita expenditure prediction using model stacking based on satellite ima...
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
Effective Security Operations Center (SOC) A Modern, Strategic, and Threat-In...
Empathic Computing: Creating Shared Understanding
Big Data Technologies - Introduction.pptx
“AI and Expert System Decision Support & Business Intelligence Systems”
Chapter 3 Spatial Domain Image Processing.pdf
Spectroscopy.pptx food analysis technology
Advanced methodologies resolving dimensionality complications for autism neur...
Network Security Unit 5.pdf for BCA BBA.
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
Reach Out and Touch Someone: Haptics and Empathic Computing
Encapsulation_ Review paper, used for researhc scholars
Unlocking AI with Model Context Protocol (MCP)
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
Programs and apps: productivity, graphics, security and other tools
Teaching material agriculture food technology

Raid

  • 1. RAID Definition and Use of the Different RAID Levels Betriebssysteme Einführung 2 Chr. Vogt Contents The different RAID levels: Definition Cost / Efficiency Reliability Performance Further High Availability Aspects Performance Optimization Features
  • 2. 3 What is RAID? 4 RAID Levels 5 Evaluation Criteria for the RAID Levels 6 RAID 0 or Striping 7 RAID 1 or Mirroring 8 RAID 0+1 (1) 9 RAID 0+1 (2) 10 RAID 3 (1) 11 RAID 3 (2) 12 RAID 5 (1) 13 RAID 5 (2) 14 Adaptive RAID 3+5 15 RAID 6 16 Further Aspects for High Availability 17 Performance Optimization Features
  • 3. Betriebssysteme Einführung 3 Chr. Vogt What is RAID? RAID (Redundant Array of Independent Disks) was first defined by Patterson, Gibson, and Katz from the Berkeley University in 1987, uses logical volumes consisting of several disks. The RAID level defines how the disks are organized, Depending on the RAID level, the reliability and/or the performance will be improved. RAID systems can be implemented in software in hardware RAID controllers external RAID subsystems RAID functionality offered by the storage arrays in a SAN (Storage Area Network) Betriebssysteme Einführung 4 Chr. Vogt RAID Levels Originally, five RAID levels were defined: RAID 1: Mirrored disks RAID 2: Hamming code for error detection RAID 3: Single parity disk, bit-interleaved parity RAID 4: Single parity disk, block-level parity RAID 5: Spread data/parity over all disks (block-level distributed parity) Later, further RAID levels were defined: RAID 0: Striped disks (no redundancy) RAID 0+1: a combination of RAID 0 and RAID 1 RAID 6: dual redundancy using a Reed-Solomon code Only RAID 0, RAID 1, RAID 0+1, and RAID 5 are commonly used today (occasionally also RAID 3, and RAID 6).
  • 4. Betriebssysteme Einführung 5 Chr. Vogt Evaluation Criteria for the RAID Levels The following aspects need to be considered when evaluating the different RAID levels: Space efficiency / cost: How much additional disk space is required for redundant data? Reliability: How many disks may fail without losing data? Also: What reliability remains after a disk failure? Performance: during normal operation, after a disk failure, during the restoration of a failed disk. In many cases read and write operations have to be considered separately, the performance also depends on the size of the I/O. Restoration: What needs to be done in order to restore the data of a failed disk. Betriebssysteme Einführung 6 Chr. Vogt RAID 0 or Striping For a RAID 0 array with n disks, data is divided into n strips which are written to the disks in a round-robin fashion. Space efficiency / cost: No redundancy, 100% storage efficiency, no extra cost. Reliability: No redundancy, no reliability. Performance: Very good, when the disks can work in parallel. Depends on the stripe size, the I/O size, and on the number of simultaneous requests.
  • 5. Betriebssysteme Einführung 7 Chr. Vogt RAID 1 or Mirroring The same data is written to two or more disks. Space efficiency / cost: 1/n for an n-fold mirror / n times as many disks are needed Reliability: n-1 disks can fail without losing data Performance: Read performance is improved: read from any disk (in parallel) Write performance is unchanged: parallel writes to all disks Restoration: Copy the data from a remaining disk in the mirror set Betriebssysteme Einführung 8 Chr. Vogt RAID 0+1 (1) RAID 0+1 is sometimes also called RAID 10. It can be built in two different ways: Space efficiency / cost: 1/n when using n-fold mirrors / n times as many disks are needed Performance: As with RAID 0 Mirrored Stripesets Striped Mirrorsets
  • 6. Betriebssysteme Einführung 9 Chr. Vogt RAID 0+1 (2) Reliability: Mirrored Stripesets: Any n-1 disks can fail without losing data (n-fold mirroring). A failing disk makes the whole stripe set inaccessible. Striped Mirrorsets: Any n-1 disks can fail without losing data (n-fold mirroring). n-1 disks can fail per mirror set in the stripe set. Restoration (of a single failed disk): Mirrored Stripesets: A whole stripeset needs to be copied from one of the remaining copies in the mirrorset. Striped Mirrorsets: The data on the failed disk needs to be copied from one of the remaining disks in the mirrorset. RAID 0+1 should always be built as striped mirrorsets, is the best possible solution when cost is not the main concern. Betriebssysteme Einführung 10 Chr. Vogt RAID 3 (1) For a RAID 3 array with n disks, data is divided into n-1 strips (typically small ones), parity information (bitwise XOR) is calculated over the n-1 strips and stored on the n-th disk. Space efficiency / cost: (n-1)/n when using n disks / 1 additional parity disk is needed Reliability: 1 disk may fail without losing data
  • 7. Betriebssysteme Einführung 11 Chr. Vogt RAID 3 (2) Performance: Normal operation: Good read performance (disks are accessed in parallel). Good write performance for large I/O requests (more than n-1 strips), because all disks are accessed in parallel. Very bad performance for small writes which access only one or few disks: read the old data from the disks, which will not be overwritten, calculate the new parity, write the new data and the new parity. After a disk failure: Performance decreases, because the missing data must be restored from the old data and the parity information. In either situation, the single parity disk can become a bottleneck. Restoration: In order to restore the contents of a failed disk, all remaining disks, including the parity disk, must be read. Hence, there will be a heavy I/O load on the disks during the restoration. Betriebssysteme Einführung 12 Chr. Vogt RAID 5 (1) For a RAID 5 array with n disks, data is divided into n-1 strips (typically large ones), parity information (bitwise XOR) is calculated over the n-1 strips, the parity information is distributed over the disks. Space efficiency / cost: (n-1)/n when using n disks / 1 additional disk is needed Reliability: 1 disk may fail without losing data
  • 8. Betriebssysteme Einführung 13 Chr. Vogt RAID 5 (2) Performance: Normal operation: Good read performance (disks are accessed in parallel). Because of the big stripe size, I/Os typically only access one or few disks. Very bad performance for small writes: read the old data that is to be changed and the old parity information, calculate the new parity (from the old data, the old parity, and the new data), write the new data and the new parity. After a disk failure: Performance decreases, because the missing data must be restored from the old data and the parity information. Restoration: In order to restore the contents of a failed disk, all remaining disks, including the parity disk, must be read. Hence, there will be a heavy I/O load on the disks during the restoration. (Same as with RAID 3.) Betriebssysteme Einführung 14 Chr. Vogt Adaptive RAID 3+5 Some vendors claim that their RAID systems (software or hardware) perform adaptive RAID 3 / RAID 5 operations. The placement of the parity information is fixed, and cannot be changed dynamically. The adaptation lies in the choice of the write algorithm, depending on the I/O size: perform large I/Os by writing all data and the parity in parallel, perform small I/Os by using the algorithm described for RAID 5.
  • 9. Betriebssysteme Einführung 15 Chr. Vogt RAID 6 For a RAID 6 array with n disks, data is divided into n-2 strips, two pieces of parity information are calculated over the n-2 strips (using a Reed-Solomon code), the parity information is distributed over the disks. Space efficiency / cost: (n-2)/n when using n disks / 2 additional disks are needed Reliability: 2 disks may fail without losing data. Performance and Restoration: Similar to RAID 5. Betriebssysteme Einführung 16 Chr. Vogt Further Aspects for High Availability RAID sets protect against the loss of data in case of a disk failure. In addition, provisions need to be taken to make the access to the data highly available, improve the performance of I/O operations. In order to make data access highly available, a RAID system should provide redundant power supplies, fans, etc. several busses for attaching the disks, redundant controllers with load balancing for the I/O requests, with cache takeover in case of a controller failure, hot-swappable components (disks, power supplies, etc.), hot spare disks to reduce the time during which a disk is missing from a RAID set.
  • 10. Betriebssysteme Einführung 17 Chr. Vogt Performance Optimization Features Caches, which can in particular improve the bad write performance of RAID3 and RAID5 sets. To avoid data inconsistencies („write hole“), caches must be protected with a battery backup. Load balancing between redundant controllers. In mirrorsets, read from the disk with the optimal head position, and/or load balance the read requests between the disks in the mirrorset. Since I/O performance often depends on the size of the I/Os, a RAID system should gather statistical information about the I/O sizes, allow the stripe size (or: chunk size) to be adjusted for each RAID set individually. Since restoring a failed disk causes a heavy additional I/O load, it should be possible to decide whether to give preference to the restore operation, in order to restore redundancy as quickly as possible, the application I/Os, in order to affect the applications as little as possible.