Inspection Services & Consulting LLC
                                          26291 Chisholm St NE Isanti MN 55040
                              Tel: 763-444-7348 Fax: 763-444-6718 Mobile: 763-350-3516
                                     Infrared-Inspector.com mninspector@msn.com




                               HOME MOISTURE INSPECTION
                                                       PREPARED FOR:
                                                      Your Name
                   _______________________________________________________________

                                           INSPECTION ADDRESS
                                12345 Your Home, Home town, Mn 12345

                                                   INSPECTION DATE
                                            7/17/2009 6:30 AM to 12;00 PM




This report is the exclusive property of the Inspection Company and the client whose
name appears herewith, and its use by any unauthorized persons is prohibited.
_____________________________________________________________________________________________
    This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                       All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 1
GENERAL INFORMATION
Inspection Address:                   12345 Your Home, Home town, Mn 12345
Inspection Date:                      7/17/2009 Time: 6:30 AM to 12;00 PM

Weather:                              Overcast - Temperature at time of inspection: 56
                                      Humidity at time of inspection: 45

Inspected by:                         Jon Anderson

Client Information:                   Your Name



Structure Type:                       Wood Frame
Foundation Type:                      Basement
Furnished:                            Yes
Structure Occupied:                   Yes
Number of Stories:                    1 story walkout

Structure Style:                      Rambler

Structure Orientation:                South

Estimated Year Built:                 2001
Unofficial Sq.Ft.:                    4000

People on Site At Time of Inspection:                     Owners

Report File: Gerald Randall




_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                       Inspection Narratives - Page 2
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________


                                                          Summary
SUMMARY
General Information
Informational Conditions
   Moisture level readings, inspections, and testing are a snap shot in time which can change over a short period
   by storms, rain dry weather patterns, humidity, temperature, lack of maintenance, structural (seismic
   movement, grade issues, life style changes, heating and cooling seasons, unrealized storm damage, gutter
   and roof ice dams, broken or leaking water pipes, and a host of other issues.

  Every effort is made to insure the accuracy of our findings, by using the best state of the art testing equipment
  available, However moisture testing is not an exact science. So all elevated moisture readings should be
  further explored to verify the readings obtained in this report.

  This is not a guarantee that every anomaly or issue will be discovered.

  If it is determined that there is structural damage, you should protect your rights.
  Contact your builder in writing of the findings, and discuss your options with an attorney.

  If there is any part of this inspection report that you do not understand, it is your responsibility to contact us to
  clarify the issue.

  Moisture wood content readings of 6% to 15% are considered normal, levels of 16% to 19% are cautionary and
  could possibly indicate a low level of moisture infiltration, Levels of 20% to 100% are considered elevated and
  should be further explored for possible damaged sheathing, framing members, and or a fungal growth

  Additional copies of your report are available for $39.00

Home Builder
Informational Conditions
   Your Contractor

Precipitation
Informational Conditions
   No Measurable precipitation within the last 24 hours

Weep Screed
Informational Conditions
   There is no weep screed installed along the foundation line.

Grade Issues
Informational Conditions
   The grade is neutral or reverse in certain areas

  The grade is high in certain areas of your home

Kick Out Flashing
Informational Conditions
   There are no kick out flashing's installed on the roof rakes.




_____________________________________________________________________________________________

      This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                         All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                        Inspection Narratives - Page 3
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

Window Details
Informational Conditions
   The windows of your home were manufactured by Andersen Windows

Drip Cap Flashing
Informational Conditions
   The windows lack drip cap flashing's

Caulking Details
Informational Conditions
   One window is caulked with a fillet bead of sealant

  The window to stucco joints are not caulked

Moisture Levels
Informational Conditions
    Area(s) of your home have elevated moisture readings over 20% which are noted within the pin probe section
   of the report.

Stains
Informational Conditions
   There is staining of the stucco below windows and the deck ledger board.
   This may or may not indicate moisture intrusion issues.

Cracks
Informational Conditions
   There are cracks in the stucco which could indicated a structural condition, seismic movement, or moisture
   intrusion.

Casing Beads
Informational Conditions
   There are no casing beads wherever the stucco intersects a hard surface




_____________________________________________________________________________________________

     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                       Inspection Narratives - Page 4
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________


                                                              Interior
Miscellaneous conditions
RIM JOIST
Informational Conditions
   The insulation of the rim joist cavity where visual was insulated with a foil faced foam insulation, and batten
   insulation.
   There is moisture staining on the surface of the foil faced foam




                             Water
                             stains




                                                                                     water
                                                                                     stains




        rust on
        insulation
        from
        foundation
        bolt




FLOOR REGISTERS
Informational Conditions
   The floor registers that were accessible were visually inspected for moisture staining.
   No staining was noted at this time




_____________________________________________________________________________________________
      This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                         All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                        Inspection Narratives - Page 5
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

Floor Registers - Continued




                                 no
                                 staining




WINDOW STAINS
Informational Conditions
   There is moisture staining or damaged finish of the window sill extension jamb area.
   This is a high indicator of moisture from within the wall cavity below the window




              moisture
              stains
                                                                                         water
                                                                                         stains
                                                                                         dining
                                                                                         room
                                                                                         window
                                                                                         head




_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                       Inspection Narratives - Page 6
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

Window Extension Jamb Staining - Continued




                                                             water
                                                             stains
                                                             dining
                                                             room
                                                             window




_____________________________________________________________________________________________

     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                       Inspection Narratives - Page 7
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________


                                                          Exterior II
EXTERIOR VISUAL (STUCCO)
KICK OUT FLASHING'S
Informational Conditions
   There are no kick out flashing's installed along the roof rakes, this is where a roof line ends or terminates into a
   sidewall.
   Rainwater running down the roof along side the wall can enter the wall system where the roof line (shingles)
   end, and cause severe damage.




          no kick out
          flashing's
          typical all
          roof rakes




CASING BEADS
Informational Conditions
   There are no casing bead or weep screed separating the stucco from the shingles, and or hard surfaces such as
   steps, patios, and driveway surfaces.




                       no
                       casing                                                                                               no
                       bead                                                                                                 casing
                                                                                                                            bead




_____________________________________________________________________________________________
      This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                         All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                        Inspection Narratives - Page 8
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

Casing Beads - Continued




                                                no
                                                casing
                                                bead




DRIP CAP FLASHING'S
Informational Conditions
   There are no drip cap flashing's over the head of the window's and or door's,
   Drip cap flashing's should be installed to prevent water intrusion at these locations.
   Check with your window manufacturer about proper installation




                              no drip
                              cap
                              flashing's




WINDOW ISSUES
Informational Conditions
   The window to stucco intersections are not caulked.
   Caulking can help prevent water infiltration around the frames




_____________________________________________________________________________________________
      This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                         All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                        Inspection Narratives - Page 9
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

No Caulking - Continued




           no
           caulking




WEEP SCREEDS
Informational Conditions
   The weep screed is installed separating the stucco from grade at the foundation line.
   Except at the paver patio on the rear elevation where the weep screed is baried
   Stucco by code is to terminate above the finished grade by 4" to 6" and is not to terminate into the grade
   (Earth)
   Properly installed weep screed prevents ground moisture from wicking up into the stucco which can attack the
   stud wall cavity and cause wood rot and a fungal growth.
   Weep screed also provides a separation so that any bulk water that is behind the stucco cladding can drain out.
   The weep screed also is used as a guide for the elevation height for any grade or landscape work.




             no
             weep                                                                                     no
             screed                                                                                   weep
                                                                                                      screed




STUCCO CRACKING
Informational Conditions
   There is cracking of the stucco cladding which resembles a road map.
   This type of cracking can indicate the presence of moisture behind the water resistant barrier, especially under
   windows, roof rakes, feature boards, and deck ledger boards.

_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 10
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________


STUCCO STAINING
Informational Conditions
   There are stains in the stucco cladding which can indicate moisture intrusion in certain circumstances

CAULKING DETAILS
Informational Conditions
   There is no caulking where the stucco meets a dissimilar material such as brick, siding water pipes electrical
   boxes, lights or vents




         no
         caulking




GRADE ISSUES
Informational Conditions
   The grade is high on the rear elevation of your home
   The grade should be down onto the foundation 4 to 6"




         grade
         is high

                                                                                                                       grade
                                                                                                                       is high




_____________________________________________________________________________________________

     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 11
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

GUTTER'S
Informational Conditions
   The downspouts are not sealed at the anchors




        downspout
        straps are
        not sealed




FEATURE BOARDS AND QUOINS
Informational Conditions
   The feature boards are installed flush with or over the window frame with little slope to the outward edge.
   This can cause severe water infiltration




                                                                                       feature
       feature                                                                         boards
                                                                                       lack an
       boards                                                                          outward
       are over                                                                        slope
       the
       window
       frames
       and no
       caulking




DECK LEDGER BOARDS
Informational Conditions
   There is no caulking or flashing at the deck ledger board.
   This is a high probability area for water infiltration




_____________________________________________________________________________________________
      This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                         All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                       Inspection Narratives - Page 12
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

No caulking at the deck ledger boards - Continued




           no
           caulking
           or bottom
           flashing




STUCCO THICKNESS
Informational Conditions
   The stucco is less than 7/8" thick, ASTM standards require conventional stucco to be installed to a total
   thickness of 7/8"




_____________________________________________________________________________________________

     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 13
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________


                                                         Pin Probe
PIN PROBE RESULTS
GENERAL PIN PROBE INFORMATION
Informational Conditions
   The following photo's are the results of your pin probe moisture level inspection.
   All moisture readings are from the sheathing unless otherwise specified.
   All moisture readings are given at the location where they were taken on the photo's.
   All readings are of wood moisture content from 6% to 100% with 6% being dry, and 100% being saturated.
   Moisture readings of 6% to 15% are considered to be normal,
   Moisture readings of 16% to 19% are considered cautionary,
   Moisture readings of 20% and higher can support mold growth and wood rot if sustained for more than 36 to 48
   hours or more and are considered elevated and should be further evaluated.

  If there is an "ss" after a moisture reading on the photo's, this indicates that the sheathing felt soft or
  deteriorated when the pin probe holes were drilled, or when the pin probes were inserted.

  If there is an "ns" on the photo's this indicates that no sheathing was detected when the pin probe holes where
  drilled, and no reading was obtained, This indicates that the sheathing is deteriorated and or completely
  missing. If there is a reading it is generally off a framing member.

  If there is a "2" after the moisture reading this indicates that the reading was taken twice for accuracy.


REFERENCE PHOTOS
Informational Conditions
   The following photos are for referencing the location of the individual pin probe photos per elevation
   The reference photos have been removed for this sample report for privacy.

FRONT ELEVATION
Informational Conditions
   FRONT ELEVATION PIN PROBE RESULTS
   Area to the left of the entry




                             8%           48%
                7% 8%        7%                   6% 7%
                                          18%

                                   39%




_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 14
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

  FRONT ELEVATION RESULTS
  Entry area




                   9%                             9%




  FRONT ELEVATION PIN PROBE RESULTS
  Area to the right of the entry


                                                                                                   99%
                                                                                                   ss

                                                                                                                                  9%

                                                                                                 99%
                                                                                                 ss


                             14%         18%
                                                                                                     27%
                                                                                                      25% ns           ns       ns




  FRONT ELEVATION PIN PROBE RESULTS
  Garage area




_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 15
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

FRONT ELEVATION 4 - Continued




                                                                                                          9%            8%
   6%



                                                                                                            34%
                                                                                                            17%

                                                                                                                                  moisture
                                                                                                                                  stains




              feature
              board is
              pushing
              out and
              moisture
              staining at
              garage
              door




LEFT ELEVATION
Informational Conditions
   LEFT ELEVATION PIN PROBE RESULTS




_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 16
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

LEFT ELEVATION 1 - Continued




                                                                                                      6%                    11%



                                                      10%
          34%


                                                                                                              16%




                              8%         8%                                                          9%          9%
                                                                                                                                            11%




REAR ELEVATION
Informational Conditions
   REAR ELEVATION PIN PROBE RESULTS
   Right side




_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 17
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

REAR ELEVATION 1 - Continued




                                             14% 9%
                     9% 8%                              10%                                        9%      12%      12%       12%
               7%
                                                                                                                                            11%
                               12%




                                      8%




                                  17%




  REAR ELEVATION PIN PROBE RESULTS
  Center area




_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 18
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

REAR ELEVATION 2 - Continued




                   10%     11%              11%      10%                                                       12% 12%
                                                                                                  11% 13%



                                     13%    16%




                                                      7%                                             7%



                    14%     12      74%      19%                                                     12%
                                    ss
                                       ns




  REAR ELEVATION PIN PROBE RESULTS
  Left area




_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 19
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

REAR ELEVATION 3 - Continued




                                                                                                  99%




                                                                                                   76%    38% 18%                  14%       19%
                                                                                                      37%
                                                                                                 99%                                        99%
                                                       12%    13%
                      13% 12% 14% 15%

                                                                                                       elevated
                                                                                                       with soft
                                                                                                       sheathing




                                            71%




RIGHT ELEVATION
Informational Conditions
   RIGHT ELEVATION PIN PROBE RESULTS
   Under the deck area




_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 20
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

RIGHT ELEVATION 1 - Continued




                                 11%                  12%
                    23%




  RIGHT ELEVATION RESULTS




                10%
                                                                                                                         12%
                                                                                                     13%

                                9%              11%




_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 21
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________

RIGHT ELEVATION 2 - Continued




                                          6%




_____________________________________________________________________________________________

     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 22
Inspection Address:      12345 Your Home, Home town, Mn 12345
 Inspection Date/Time:    7/17/2009 6:30 AM to 12;00 PM
_____________________________________________________________________________________________


HOME MOISTURE INSPECTION                                                                                                                    1
GENERAL INFORMATION                                                                                                                         2
Summary                                                                                                                                     3
   SUMMARY                                                                                                                                  3
Interior                                                                                                                                    5
   Miscellaneous conditions                                                                                                                 5
Exterior II                                                                                                                                 8
   EXTERIOR VISUAL (STUCCO)                                                                                                                 8
Pin Probe                                                                                                                                   14
   PIN PROBE RESULTS                                                                                                                        14
INDEX                                                                                                                                       22




_____________________________________________________________________________________________
     This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
                        All printed comments and the opinions expressed herein are those of the Inspection Company.
                                                      Inspection Narratives - Page 22
Inspection Services & Consulting LLC
                                    26291 Chisholm St NE Isanti MN 55040
                         Tel: 763-444-7348 Fax: 763-444-6718 Mobile: 763-350-3516
                                    Email Address: mninspector@msn.com



Property Address:    12345 Your Home, Home town, Mn 12345
Inspection Date:     7/17/2009 Time: 6:30 AM to 12;00 PM

763-421-5138

Dear Your Name:

  Thank you for hiring Inspection Services & Consulting LLC to be of service. We hope that you were pleased
  with the quality of our service, and that you would recommend us to others. Please read the report carefully,
  and call us with any questions that you might have. We remain your consultant, and would be happy to assist
  you in any way that we can. We sincerely hope that you and your family will be happy and healthy in your
  home.

  Sincerely,
  Jon Anderson CEI CIT CHI CEI
  Inspection Services & Consulting LLC

More Related Content

PDF
Sample report
DOC
GC3 - Hazard NEW
PDF
J McGinty_NEBOSH Certificate in Occupational Health & Safety
PDF
HR / Talent Analytics
PDF
1 house-inspections report
PDF
Full House Inspections Sample Report
PDF
Sample Residential Inspection Report
PPT
Rental Application
Sample report
GC3 - Hazard NEW
J McGinty_NEBOSH Certificate in Occupational Health & Safety
HR / Talent Analytics
1 house-inspections report
Full House Inspections Sample Report
Sample Residential Inspection Report
Rental Application

Similar to Sample report 3 (20)

PDF
Pre insp contract
PDF
Sample report
PDF
Sample report
PDF
Home inspection-agreement
PDF
Sample RS 6-10-15
PDF
2009 12 10 Lead Disclosure
PDF
Sample 2007 built_rural_area
PDF
Real estate transfer disclosure statement (rtds)
PPT
Minimize Your Risk, Maximize Your Earnings!
PPTX
What’s the Average Cost of Slab Foundation Repair in San Antonio?
PPT
Home Inspections
PDF
C4 Homepros Guide Issue 2: Winter 2024 (South Charlotte/ Fort Mill)
PDF
OC Roadshow hosted by CL King New York
PDF
Sample commercial inspection
PDF
A and N Mortgage’s Home Buying Packet
PDF
A and N Mortgage\'s Home Buying Packet
PPTX
Brief presentation for supervisors.
DOC
Home Inspection Report
PDF
DO I NEED A FOUNDATION INSPECTION?
PDF
3M Scotch 35 White Vinyl Electrical Colour Coding Tape - 3M Electrical Tapes
Pre insp contract
Sample report
Sample report
Home inspection-agreement
Sample RS 6-10-15
2009 12 10 Lead Disclosure
Sample 2007 built_rural_area
Real estate transfer disclosure statement (rtds)
Minimize Your Risk, Maximize Your Earnings!
What’s the Average Cost of Slab Foundation Repair in San Antonio?
Home Inspections
C4 Homepros Guide Issue 2: Winter 2024 (South Charlotte/ Fort Mill)
OC Roadshow hosted by CL King New York
Sample commercial inspection
A and N Mortgage’s Home Buying Packet
A and N Mortgage\'s Home Buying Packet
Brief presentation for supervisors.
Home Inspection Report
DO I NEED A FOUNDATION INSPECTION?
3M Scotch 35 White Vinyl Electrical Colour Coding Tape - 3M Electrical Tapes
Ad

Recently uploaded (20)

PDF
1.3 FINAL REVISED K-10 PE and Health CG 2023 Grades 4-10 (1).pdf
DOCX
Cambridge-Practice-Tests-for-IELTS-12.docx
PDF
advance database management system book.pdf
DOC
Soft-furnishing-By-Architect-A.F.M.Mohiuddin-Akhand.doc
PPTX
A powerpoint presentation on the Revised K-10 Science Shaping Paper
PDF
Empowerment Technology for Senior High School Guide
PPTX
202450812 BayCHI UCSC-SV 20250812 v17.pptx
PDF
My India Quiz Book_20210205121199924.pdf
PPTX
Share_Module_2_Power_conflict_and_negotiation.pptx
PPTX
Onco Emergencies - Spinal cord compression Superior vena cava syndrome Febr...
PDF
Environmental Education MCQ BD2EE - Share Source.pdf
PDF
HVAC Specification 2024 according to central public works department
PDF
Chinmaya Tiranga quiz Grand Finale.pdf
PPTX
20th Century Theater, Methods, History.pptx
PPTX
Computer Architecture Input Output Memory.pptx
PDF
AI-driven educational solutions for real-life interventions in the Philippine...
PDF
Hazard Identification & Risk Assessment .pdf
PDF
Trump Administration's workforce development strategy
PPTX
Virtual and Augmented Reality in Current Scenario
PPTX
TNA_Presentation-1-Final(SAVE)) (1).pptx
1.3 FINAL REVISED K-10 PE and Health CG 2023 Grades 4-10 (1).pdf
Cambridge-Practice-Tests-for-IELTS-12.docx
advance database management system book.pdf
Soft-furnishing-By-Architect-A.F.M.Mohiuddin-Akhand.doc
A powerpoint presentation on the Revised K-10 Science Shaping Paper
Empowerment Technology for Senior High School Guide
202450812 BayCHI UCSC-SV 20250812 v17.pptx
My India Quiz Book_20210205121199924.pdf
Share_Module_2_Power_conflict_and_negotiation.pptx
Onco Emergencies - Spinal cord compression Superior vena cava syndrome Febr...
Environmental Education MCQ BD2EE - Share Source.pdf
HVAC Specification 2024 according to central public works department
Chinmaya Tiranga quiz Grand Finale.pdf
20th Century Theater, Methods, History.pptx
Computer Architecture Input Output Memory.pptx
AI-driven educational solutions for real-life interventions in the Philippine...
Hazard Identification & Risk Assessment .pdf
Trump Administration's workforce development strategy
Virtual and Augmented Reality in Current Scenario
TNA_Presentation-1-Final(SAVE)) (1).pptx
Ad

Sample report 3

  • 1. Inspection Services & Consulting LLC 26291 Chisholm St NE Isanti MN 55040 Tel: 763-444-7348 Fax: 763-444-6718 Mobile: 763-350-3516 Infrared-Inspector.com mninspector@msn.com HOME MOISTURE INSPECTION PREPARED FOR: Your Name _______________________________________________________________ INSPECTION ADDRESS 12345 Your Home, Home town, Mn 12345 INSPECTION DATE 7/17/2009 6:30 AM to 12;00 PM This report is the exclusive property of the Inspection Company and the client whose name appears herewith, and its use by any unauthorized persons is prohibited. _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 1
  • 2. GENERAL INFORMATION Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date: 7/17/2009 Time: 6:30 AM to 12;00 PM Weather: Overcast - Temperature at time of inspection: 56 Humidity at time of inspection: 45 Inspected by: Jon Anderson Client Information: Your Name Structure Type: Wood Frame Foundation Type: Basement Furnished: Yes Structure Occupied: Yes Number of Stories: 1 story walkout Structure Style: Rambler Structure Orientation: South Estimated Year Built: 2001 Unofficial Sq.Ft.: 4000 People on Site At Time of Inspection: Owners Report File: Gerald Randall _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 2
  • 3. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ Summary SUMMARY General Information Informational Conditions Moisture level readings, inspections, and testing are a snap shot in time which can change over a short period by storms, rain dry weather patterns, humidity, temperature, lack of maintenance, structural (seismic movement, grade issues, life style changes, heating and cooling seasons, unrealized storm damage, gutter and roof ice dams, broken or leaking water pipes, and a host of other issues. Every effort is made to insure the accuracy of our findings, by using the best state of the art testing equipment available, However moisture testing is not an exact science. So all elevated moisture readings should be further explored to verify the readings obtained in this report. This is not a guarantee that every anomaly or issue will be discovered. If it is determined that there is structural damage, you should protect your rights. Contact your builder in writing of the findings, and discuss your options with an attorney. If there is any part of this inspection report that you do not understand, it is your responsibility to contact us to clarify the issue. Moisture wood content readings of 6% to 15% are considered normal, levels of 16% to 19% are cautionary and could possibly indicate a low level of moisture infiltration, Levels of 20% to 100% are considered elevated and should be further explored for possible damaged sheathing, framing members, and or a fungal growth Additional copies of your report are available for $39.00 Home Builder Informational Conditions Your Contractor Precipitation Informational Conditions No Measurable precipitation within the last 24 hours Weep Screed Informational Conditions There is no weep screed installed along the foundation line. Grade Issues Informational Conditions The grade is neutral or reverse in certain areas The grade is high in certain areas of your home Kick Out Flashing Informational Conditions There are no kick out flashing's installed on the roof rakes. _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 3
  • 4. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ Window Details Informational Conditions The windows of your home were manufactured by Andersen Windows Drip Cap Flashing Informational Conditions The windows lack drip cap flashing's Caulking Details Informational Conditions One window is caulked with a fillet bead of sealant The window to stucco joints are not caulked Moisture Levels Informational Conditions Area(s) of your home have elevated moisture readings over 20% which are noted within the pin probe section of the report. Stains Informational Conditions There is staining of the stucco below windows and the deck ledger board. This may or may not indicate moisture intrusion issues. Cracks Informational Conditions There are cracks in the stucco which could indicated a structural condition, seismic movement, or moisture intrusion. Casing Beads Informational Conditions There are no casing beads wherever the stucco intersects a hard surface _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 4
  • 5. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ Interior Miscellaneous conditions RIM JOIST Informational Conditions The insulation of the rim joist cavity where visual was insulated with a foil faced foam insulation, and batten insulation. There is moisture staining on the surface of the foil faced foam Water stains water stains rust on insulation from foundation bolt FLOOR REGISTERS Informational Conditions The floor registers that were accessible were visually inspected for moisture staining. No staining was noted at this time _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 5
  • 6. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ Floor Registers - Continued no staining WINDOW STAINS Informational Conditions There is moisture staining or damaged finish of the window sill extension jamb area. This is a high indicator of moisture from within the wall cavity below the window moisture stains water stains dining room window head _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 6
  • 7. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ Window Extension Jamb Staining - Continued water stains dining room window _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 7
  • 8. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ Exterior II EXTERIOR VISUAL (STUCCO) KICK OUT FLASHING'S Informational Conditions There are no kick out flashing's installed along the roof rakes, this is where a roof line ends or terminates into a sidewall. Rainwater running down the roof along side the wall can enter the wall system where the roof line (shingles) end, and cause severe damage. no kick out flashing's typical all roof rakes CASING BEADS Informational Conditions There are no casing bead or weep screed separating the stucco from the shingles, and or hard surfaces such as steps, patios, and driveway surfaces. no casing no bead casing bead _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 8
  • 9. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ Casing Beads - Continued no casing bead DRIP CAP FLASHING'S Informational Conditions There are no drip cap flashing's over the head of the window's and or door's, Drip cap flashing's should be installed to prevent water intrusion at these locations. Check with your window manufacturer about proper installation no drip cap flashing's WINDOW ISSUES Informational Conditions The window to stucco intersections are not caulked. Caulking can help prevent water infiltration around the frames _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 9
  • 10. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ No Caulking - Continued no caulking WEEP SCREEDS Informational Conditions The weep screed is installed separating the stucco from grade at the foundation line. Except at the paver patio on the rear elevation where the weep screed is baried Stucco by code is to terminate above the finished grade by 4" to 6" and is not to terminate into the grade (Earth) Properly installed weep screed prevents ground moisture from wicking up into the stucco which can attack the stud wall cavity and cause wood rot and a fungal growth. Weep screed also provides a separation so that any bulk water that is behind the stucco cladding can drain out. The weep screed also is used as a guide for the elevation height for any grade or landscape work. no weep no screed weep screed STUCCO CRACKING Informational Conditions There is cracking of the stucco cladding which resembles a road map. This type of cracking can indicate the presence of moisture behind the water resistant barrier, especially under windows, roof rakes, feature boards, and deck ledger boards. _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 10
  • 11. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ STUCCO STAINING Informational Conditions There are stains in the stucco cladding which can indicate moisture intrusion in certain circumstances CAULKING DETAILS Informational Conditions There is no caulking where the stucco meets a dissimilar material such as brick, siding water pipes electrical boxes, lights or vents no caulking GRADE ISSUES Informational Conditions The grade is high on the rear elevation of your home The grade should be down onto the foundation 4 to 6" grade is high grade is high _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 11
  • 12. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ GUTTER'S Informational Conditions The downspouts are not sealed at the anchors downspout straps are not sealed FEATURE BOARDS AND QUOINS Informational Conditions The feature boards are installed flush with or over the window frame with little slope to the outward edge. This can cause severe water infiltration feature feature boards lack an boards outward are over slope the window frames and no caulking DECK LEDGER BOARDS Informational Conditions There is no caulking or flashing at the deck ledger board. This is a high probability area for water infiltration _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 12
  • 13. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ No caulking at the deck ledger boards - Continued no caulking or bottom flashing STUCCO THICKNESS Informational Conditions The stucco is less than 7/8" thick, ASTM standards require conventional stucco to be installed to a total thickness of 7/8" _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 13
  • 14. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ Pin Probe PIN PROBE RESULTS GENERAL PIN PROBE INFORMATION Informational Conditions The following photo's are the results of your pin probe moisture level inspection. All moisture readings are from the sheathing unless otherwise specified. All moisture readings are given at the location where they were taken on the photo's. All readings are of wood moisture content from 6% to 100% with 6% being dry, and 100% being saturated. Moisture readings of 6% to 15% are considered to be normal, Moisture readings of 16% to 19% are considered cautionary, Moisture readings of 20% and higher can support mold growth and wood rot if sustained for more than 36 to 48 hours or more and are considered elevated and should be further evaluated. If there is an "ss" after a moisture reading on the photo's, this indicates that the sheathing felt soft or deteriorated when the pin probe holes were drilled, or when the pin probes were inserted. If there is an "ns" on the photo's this indicates that no sheathing was detected when the pin probe holes where drilled, and no reading was obtained, This indicates that the sheathing is deteriorated and or completely missing. If there is a reading it is generally off a framing member. If there is a "2" after the moisture reading this indicates that the reading was taken twice for accuracy. REFERENCE PHOTOS Informational Conditions The following photos are for referencing the location of the individual pin probe photos per elevation The reference photos have been removed for this sample report for privacy. FRONT ELEVATION Informational Conditions FRONT ELEVATION PIN PROBE RESULTS Area to the left of the entry 8% 48% 7% 8% 7% 6% 7% 18% 39% _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 14
  • 15. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ FRONT ELEVATION RESULTS Entry area 9% 9% FRONT ELEVATION PIN PROBE RESULTS Area to the right of the entry 99% ss 9% 99% ss 14% 18% 27% 25% ns ns ns FRONT ELEVATION PIN PROBE RESULTS Garage area _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 15
  • 16. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ FRONT ELEVATION 4 - Continued 9% 8% 6% 34% 17% moisture stains feature board is pushing out and moisture staining at garage door LEFT ELEVATION Informational Conditions LEFT ELEVATION PIN PROBE RESULTS _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 16
  • 17. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ LEFT ELEVATION 1 - Continued 6% 11% 10% 34% 16% 8% 8% 9% 9% 11% REAR ELEVATION Informational Conditions REAR ELEVATION PIN PROBE RESULTS Right side _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 17
  • 18. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ REAR ELEVATION 1 - Continued 14% 9% 9% 8% 10% 9% 12% 12% 12% 7% 11% 12% 8% 17% REAR ELEVATION PIN PROBE RESULTS Center area _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 18
  • 19. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ REAR ELEVATION 2 - Continued 10% 11% 11% 10% 12% 12% 11% 13% 13% 16% 7% 7% 14% 12 74% 19% 12% ss ns REAR ELEVATION PIN PROBE RESULTS Left area _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 19
  • 20. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ REAR ELEVATION 3 - Continued 99% 76% 38% 18% 14% 19% 37% 99% 99% 12% 13% 13% 12% 14% 15% elevated with soft sheathing 71% RIGHT ELEVATION Informational Conditions RIGHT ELEVATION PIN PROBE RESULTS Under the deck area _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 20
  • 21. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ RIGHT ELEVATION 1 - Continued 11% 12% 23% RIGHT ELEVATION RESULTS 10% 12% 13% 9% 11% _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 21
  • 22. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ RIGHT ELEVATION 2 - Continued 6% _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 22
  • 23. Inspection Address: 12345 Your Home, Home town, Mn 12345 Inspection Date/Time: 7/17/2009 6:30 AM to 12;00 PM _____________________________________________________________________________________________ HOME MOISTURE INSPECTION 1 GENERAL INFORMATION 2 Summary 3 SUMMARY 3 Interior 5 Miscellaneous conditions 5 Exterior II 8 EXTERIOR VISUAL (STUCCO) 8 Pin Probe 14 PIN PROBE RESULTS 14 INDEX 22 _____________________________________________________________________________________________ This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein. All printed comments and the opinions expressed herein are those of the Inspection Company. Inspection Narratives - Page 22
  • 24. Inspection Services & Consulting LLC 26291 Chisholm St NE Isanti MN 55040 Tel: 763-444-7348 Fax: 763-444-6718 Mobile: 763-350-3516 Email Address: mninspector@msn.com Property Address: 12345 Your Home, Home town, Mn 12345 Inspection Date: 7/17/2009 Time: 6:30 AM to 12;00 PM 763-421-5138 Dear Your Name: Thank you for hiring Inspection Services & Consulting LLC to be of service. We hope that you were pleased with the quality of our service, and that you would recommend us to others. Please read the report carefully, and call us with any questions that you might have. We remain your consultant, and would be happy to assist you in any way that we can. We sincerely hope that you and your family will be happy and healthy in your home. Sincerely, Jon Anderson CEI CIT CHI CEI Inspection Services & Consulting LLC