ABSTRACT
Shear walls and outriggers have been used so far to resist theseismicwavesof
earthquake and heavy winds actions. The complete failure of the structures
that has occurred in the past due to catastrophic earthquake may be avoided
with the use of shear wall in the structure. The studyisconcernedwiththeuse
of shear wall as a single core in structure that will resist the seismic waves of
earthquake. In the present study analysis of RCC buildinghasbeencarriedout
by changing the locations of shear walls in the building. The seismic analysis
performed is linear dynamic response spectrum analysis using the well-
known analysis and design softwareETABS16.2.0.Seismicperformanceofthe
building has been investigated based on parameterssuchasstroreydrift, base
shear and storey displacement.
KEYWORDS: Shear walls, Outriggers, Single Core
How to cite this paper: Belsare Sumit
Bandopanth | Dilip Budhlani "Seismic
Response of Structure with Single Core"
Published in
International Journal
of Trend in Scientific
Research and
Development
(ijtsrd), ISSN: 2456-
6470, Volume-4 |
Issue-3, April 2020,
pp.1131-1136, URL:
www.ijtsrd.com/papers/ijtsrd30851.pdf
Copyright © 2020 by author(s) and
International Journal ofTrendinScientific
Research and Development Journal. This
is an Open Access article distributed
under the terms of
the Creative
CommonsAttribution
License (CC BY 4.0)
(http://creativecommons.org/licenses/by
/4.0)
1. INTRODUCTION
The Displacement of a tall building caused by horizontal
forces due to wind or earthquake can be reduced by the
provision of core. The core is the main lateral force-resistant
component. The maximum horizontal displacement is
limited by codes for the stability of the building and for the
comfort of its occupants. Also,thecodeslimittheinterstorey
drift ratio, defined as the difference of drift in two
consecutive floors divided by the vertical distance between
them. The sum of the moments at the ends of a column at a
floor level is a couple transferred, in the opposite direction,
to the floor; the floor must be designed for the flexural and
shear stress caused by the transfer. The moments
transferred between the columns and the floors are mainly
dependent on the inter storey drift ratio.
The primary purpose of different types of structural system
in buildings is to resist gravity loads like dead, live loads.
Besides these vertical loads, lateral loads caused by wind,
earthquake also acts on buildings. It is very important that
structure should resist both vertical loads and lateral loads.
The shear wall-frame system is the most commonly used
structural system in reinforced concrete buildings to
counteract the effect of both gravity and horizontal loads.
These shear wall-frame system have high lateral resistance
against horizontal loads by placing shear walls in an
advantageous location in the plan of building.
Shear Wall
Shear walls are vertical reinforced concrete structural
elements to resist both gravityandlateral loadsactingonthe
structure. The thickness of wall varies from 200 to 500mm,
depends on the height of the building and seismic zone of
building area. They are different types of shear walls in
building system 1) simple rectangulartypeandflangedwalls
2) coupled shear wall 3) core type shear wall. The simple
rectangular wall is generally placed between periphery
columns of building and core walls are placed around the
staircase and elevator to resist the vibration loads and
lateral loads. In the present study core wall are included in
the building frame. Normally the civil engineeringstructures
are designed within the elastic range, but under a strong
seismic event, a structure may really be subjected to forces
past its flexible breaking point. In spite of the fact that
construction laws can give a dependable sign of real
execution of individual structural components, it is out of
their extension to depict the normal execution of planned
structure as a whole, under huge forces. A few businesses,
for example, car and flight, routinely construct full-scale
models and perform broad testing,beforeassemblinga large
number of indistinguishable structures, that have been
examined and composed with the thought of test outcomes.
Unfortunately, this choice is not accessible to building
industry as because of the uniqueness of normal individual
structures, the economy of substantial scale creation is
unachievable.
IJTSRD30851
International Journal of Trend in Scientific Research and Development (IJTSRD) @ www.ijtsrd.com eISSN: 2456-6470
@ IJTSRD | Unique Paper ID – IJTSRD30851 | Volume – 4 | Issue – 3 | March-April 2020 Page 1132
Figure 1 Types of shear walls
Outriggers
Although outriggers have been used for approximately four
decades, their existence as a structural member has a much
longer history. Outriggers have been used in the sailing ship
industry for many years. They are used to resist wind. The
slender mast provides the use ofoutriggers.Asa comparison
the core can be related to the mast, the outriggers are like
the spreaders and the exterior columns are like the shrouds
or stays. Innovative structural schemes are continuously
being sought in the field. Structural Design of High-Rise
Structures with the intention of limiting the Drift due to
Lateral Loads to acceptable limits without paying a high
premium in steel tonnage. The savings in steel tonnage and
cost can be dramatic if certain techniques are employed to
utilize the full capacities of the structural elements. Various
wind bracing techniques havebeendevelopedinthisregard;
one such is an Outrigger System, in which the axial stiffness
of the peripheral columns is invoked for increasing the
resistance to overturning moments. This efficient structural
form consists of a central core, comprising either Braced
Frames or Shear Walls, with horizontal cantilever trusses or
girders known as outrigger Trusses, connecting the core to
the outer columns. The core may be centrally located with
outriggers extending on both sides (Fig.2.a) or it may be
located on one side of the building withoutriggersextending
to the building columns on one side (Fig.2.b).
Fig.2 (a) Outrigger system with a central core (b)
Outrigger system with offset core
When Horizontal loading acts on the building, the column
restrained outriggers resist the rotation of the core, causing
the lateral deflections and moments in the coretobesmaller
than if the free-standing core alone resisted the loading. The
result is to increase the effective depth ofthestructurewhen
it flexes as a vertical cantilever, by inducing tension in the
windward columns and Compression in the leeward
columns. In addition to those columns located at the ends of
the outriggers, it is usual to also mobilize other peripheral
columns to assist in restraining the outriggers. This is
achieved by including a deep Spandrel Girder, or a Belt
Truss, around the structure at the levels oftheoutriggers. To
make the Outriggers and Belt Truss adequately stiff in
flexure and shear, they are made at least one, and often 2 –
stories deep. It is also possible to use diagonals extending
through several floors to act as outriggers. And finally,
girders at each floor may be transformed into outriggers by
moment connections to the core and, if desired, to the
exterior columns as well. Here, it should be noted that while
the outrigger system is very effective in increasing the
structure’s flexural stiffness,itdoesn’tincreaseitsresistance
to shear, which has to be carried mainly by the core.
(C)
Fig.3 Diagonals acting as outriggers
2. CASE STUDY
Study is carried out by ModelingoftheG+20storeybuildings
with core shear wall and braced core at center, corner and
side in ETABS 2016. During the analysis various IS codes
have been adopted such as IS: 456 for concrete design, IS:
875 for loads, IS: 800 for steel design, IS: 1893-2016 for
seismic design. The seismic effect on the structure has been
studied using responsespectrummethodandcorresponding
various parameters has been tabulated.
The main seismic parameters that are compared are
maximum displacement, storey drift,baseshear,timeperiod
and axial force and moments in columns. The following
various parameters were considered for modelling and
Analysis of the structure in ETABS.
Building Plan and its Geometry
The plan area of the building is kept 21 m x 21 m. Height of
each storey is kept uniform i.e. 3 m. so the total height of the
building is 63m. Number of bay in x direction is 5 and
Number of bay in y direction is 5, the bay widthinxdirection
is 4.2 m, the bay width in y direction is 4.2m.
Various type of structural model considered for this
study.
Model 1- Symmetric plan frame without center core.
Model 2- Symmetric plan frame without corner core.
Model 3- Symmetric plan frame without side core.
Model 4- Symmetric plan frame with center shear wall
(SW) core.
Model 5- Symmetric plan frame with corner shear wall
(SW) core.
Model 6- Symmetric plan frame with side shear wall
(SW) core.
International Journal of Trend in Scientific Research and Development (IJTSRD) @ www.ijtsrd.com eISSN: 2456-6470
@ IJTSRD | Unique Paper ID – IJTSRD30851 | Volume – 4 | Issue – 3 | March-April 2020 Page 1133
Model 7- Symmetric plan frame with centerbraced(BR)
core.
Model 8- Symmetric plan framewithcorner braced(BR)
core.
Model 9- Symmetric plan frame with side braced (BR)
core.
Model 10- Asymmetric plan frame without center core.
Model 11- Asymmetric plan frame without corner core.
Model 12- Asymmetric plan frame without side core.
Model 13- Asymmetric plan frame with center shear
wall (SW) core.
Model 14- Asymmetric plan frame with corner shear
wall (SW) core.
Model 15- Asymmetric plan frame with side shear wall
(SW) core.
Model 16- Asymmetric plan frame with center braced
(BR) core.
Model 17- Asymmetric plan frame with corner braced
(BR) core.
Model 18- Asymmetric planframewithside braced(BR)
core.
Model 19- AsymmetricL planframewithoutcentercore.
Model 20- Asymmetric L plan frame without corner
core.
Model 21- Asymmetric L plan frame without side core.
Model 22- Asymmetric L plan frame with center shear
wall (SW) core.
Model 23- Asymmetric L plan frame with corner shear
wall (SW) core.
Model 24- Asymmetric L plan framewithsideshear wall
(SW) core.
Model 25- Asymmetric L plan frame with center braced
(BR) core.
Model 26- Asymmetric L plan frame with corner braced
(BR) core.
Model 27- Asymmetric L plan frame with side braced
(BR) core.
Material properties
Concrete of grade M35, steel grade of Fe 345 and Rebar of
grade Fe500 is used for modeled the building. The poison’s
ratio for concrete and steel is taken as 0.3. The density of
concrete is 25kN/m³ and density of brick masonry is 20
KN/m3 is considered for modeled the building.
Member dimensions
The dimensions of members are decided by observing the
stability aspect table 1 shows thememberdimensionswhich
have used in all models of building.
Table 1 Member Dimensions
Member Size
Thickness of RCC Slab 150 mm
Beam Size 230 mm x 500 mm
Column Size 600 mm x 600 mm
Thickness of Brick Masonry wall 230 mm
Thickness of RCC Shearwall 250 mm
Steel Outriggers ISA 150 x 150 x 15 mm
Load details
Following are the details of loads which has considered in
this analysis and design of Building.
A. Dead load: - In ETABS the software itself calculates the
dead loads by applying a self-weightmultiplierfactorof
one which is taken by the structure and the rest load
cases are kept zero. Its defined in the load patterns
section.
B. Live load on floors: - 2.5 KN/m² as per IS:875 (part -2).
C. Live load on roof: - 1.5 KN/m² as per IS:875 (part -2).
D. Wall load on all levels: - 3 x 0.23 x 20 = 11.5 KN/m.
Seismic Data
Zone Factor: - Zone III (0.16)
Importance factor: - 1.2 (Residential building with
occupancy more than 200 persons)
Response Reduction Factor: - 5 Special moment resisting
frame (SMRF)
Soil Type: - II Medium
Damping Ratio: - 5%
Load Combinations
Each model of the building is subjected to Dead Load, Live
Load and Seismic Forces in –
(+) X and (-) X Direction
(+) Y and (-) Y Direction
After applying above load each model of the building is
analyzed for dynamic method under the following load
combination generated automatically using ETABS: -
1.5 x [DL-Self Weight]
1.5 x [DL + LL]
1.2 x [DL + LL + EQX]
1.2 x [DL + LL - EQX]
1.2 x [DL + LL + EQX-]
1.2 x [DL + LL – EQX-]
1.2 x [DL + LL + EQY]
1.2 x [DL + LL - EQY]
1.2 x [DL + LL + EQY-]
1.2 x [DL + LL – EQY-]
1.5 x [DL + EQX]
1.5 x [DL - EQX]
1.5 x [DL + EQX-]
1.5 x [DL - EQX-]
1.5 x [DL + EQY]
1.5 x [DL - EQY]
1.5 x [DL + EQY-]
1.5 x [DL - EQY-]
0.9 DL + 1.5 EQX
0.9 DL - 1.5 EQX
0.9 DL + 1.5 EQX-
0.9 DL - 1.5 EQX-
0.9 DL + 1.5 EQY
0.9 DL - 1.5 EQY
0.9 DL + 1.5 EQY
0.9 DL - 1.5 EQY
3. METHODOLOGY OF PROPOSED WORK
A. Modeling of the twenty storey buildings with coreshear
wall and braced core at center, corner and side in
ETABS.
B. Application of gravity loads (dead, live, wall load) asper
Indian codes and lateral loadsasperIS1893:2002. Since
the live load class is up to 3 KN/m2, 25% of the imposed
load has been considered.
C. Analyzing the building using Response spectrum
analysis with fixed support.
D. Comparing the results of building models.
International Journal of Trend in Scientific Research and Development (IJTSRD) @ www.ijtsrd.com eISSN: 2456-6470
@ IJTSRD | Unique Paper ID – IJTSRD30851 | Volume – 4 | Issue – 3 | March-April 2020 Page 1134
4. MODELLING
General
In this study, total twenty-seven models are considered to
perform the seismic analysis. All the models having 20
stories and height of each storey was 3m. First nine models
are in the square plan of 21m x 21m with 5 bays on eachside
and the next eighteen models are asymmetric in plan. In all
the models the lateral loads are resisted by withandwithout
single core (SW & BR) with varying position of core.
Response spectrum method of seismicanalysisiscarried out
as per IS 1893:2016. Modeling and analysis are done in
ETABS software.
Response Spectrum Analysis
Earthquake engineers preferred to report an interaction
between the acceleration of ground and structural system
through response spectrum first proposed by Biot and later
popularized by Housner. A Response spectrum is a plot of
the maximum response of a set ofSDOF systemssubjected to
ground motion as ordinate and corresponding time periods
of the SDOF system as abscissa. This methodisapplicable for
those structures where modes other than the basic mode
that influences the structure reaction. In this method the
Multi-degree-of-Freedom (MDOF) system response is
expressed as the superposition of modal response, by the
spectral analysisofsingle-degree-of-freedom(SDOF)system,
the response of each mode beingdetermined, whicharethen
combined to find out the total response.
Methods of combining modal response:
A. Absolute – peak values are added together
B. Square root of the sum of the squares (SRSS)
C. Complete quadratic combination (CQC)
Fig.4 Response Spectrum Curve
Building Models
Fig.5 Model 1- Symmetric plan frame without center
core
Fig.6 Model 2- Symmetric plan frame without corner
core
Fig.7 Model 3 - Symmetric plan frame without side
core
Fig.8 Model 4 - symmetric plan frame with center
shear wall (SW) core.
Fig.9 Model 5 - symmetric plan frame with corner
shear wall (SW) core.
International Journal of Trend in Scientific Research and Development (IJTSRD) @ www.ijtsrd.com eISSN: 2456-6470
@ IJTSRD | Unique Paper ID – IJTSRD30851 | Volume – 4 | Issue – 3 | March-April 2020 Page 1135
Fig. 10 Model 6 - symmetric plan frame with side shear
wall (SW) core.
Fig. 11 Model 10 – Asymmetric plan frame without
center core.
Fig.12 Model 11 -Asymmetric plan frame without
corner core.
Fig.13 Model 12 - Asymmetric plan frame without side
core.
Fig.14 Model 13 - Asymmetric plan frame with center
shear wall (SW) core
Fig.15 Model 14 - Asymmetric plan frame with corner
shear wall (SW) core
Fig. 16 Model 15 - Asymmetric plan frame with side
shear wall (SW) core.
Fig.17 Model 19 - Asymmetric L plan frame without
center core.
International Journal of Trend in Scientific Research and Development (IJTSRD) @ www.ijtsrd.com eISSN: 2456-6470
@ IJTSRD | Unique Paper ID – IJTSRD30851 | Volume – 4 | Issue – 3 | March-April 2020 Page 1136
Fig.18 Model 20 - Asymmetric L plan frame without
corner core.
Fig.19 Model 21 - Asymmetric L plan frame without
side core.
Fig.20 Model 22 - Asymmetric L plan frame with
center shear wall (SW) core.
Fig.21 Model 23 - Asymmetric L plan frame with
Corner shear wall (SW) core.
Fig.22 Model 24 - Asymmetric L plan frame with side
shear wall (SW) core.
5. CONCLUSION
Satisfying the requirement of the stability conditions for a
single core structure will becomplicatedone,comparedwith
the structures supported in all sides depending upon their
configuration. Single core structureisa critical onewhenitis
subjected to unsymmetrical and eccentric loading
conditions. Eccentric loading will causethestructuretotwist
in any direction and may cause failure of structure. By the
study, we want to explore a new dimension of the existing
construction techniques. This study describes planning,
structural analysis and design of the single core building.
The Buildings with single core at corner and side position
tends to go in Torsion Mode which develops extra forces in
the frames. Greater Economy can be achievedbykeepingthe
single Cores at Centre of the Buildings. Building at center
core will gives economical design as well as sufficient
amount of safety.
6. REFERENCE
[1] IS: 1893 PART 1 (2016) “Criteria for Earthquake
Resistant Design of Structures– general provisionsand
buildings” Bureau of Indian Standards, New Delhi.
[2] Jibi Abraham “Seismic Analysis Of Pyramid Shaped
Building With And Without Bracing” , published in
International Research Journal of Engineering and
Technology (IRJET) Volume: 05 Issue: 05 | May-2018,
ISSN: 2395-0056
[3] Maikesh Chouhan, ‘Dynamic AnalysisofMulti-Storeyed
Frame-Shear Wall Building Considering SSI’, published
in International Journal of Engineering Research and
Application Vol. 6, Issue 8, ( Part -1) August 2016,
pp.31-35 www. ijera.com ISSN : 2248-9622
[4] Pavan Kumar, ‘Earthquake Analysis of Multi Storied
Residential Building - A Case Study’, published in
International Journal of Engineering Research and
Applications www.ijera.com, Vol. 4, Issue 11( Version
1), November 2014, pp.59-64, ISSN : 2248-9622
[5] Abrar Ahmed, ‘Seismic Analysis On Building With
Horizontal And Vertical Irregularities’, published in
International Journal of Advance Engineering and
Research Development Volume 4, Issue 9, September -
2017

More Related Content

DOC
Project report
PDF
C046031318
PDF
Research non seismic walls
PDF
STUDY ON SEISMIC EFFECT OF HIGH RISE BUILDING SHEAR WALL/WALL WITHOUT SHEAR WALL
PDF
Performance of shear wall building during seismic excitations
PDF
Effect of steel bracing on vertically irregular r.c.c building frames under s...
PDF
Rc4 lecture 2- eng. samer akil
PDF
Study of lateral load resisting systems of variable heights in all soil types...
Project report
C046031318
Research non seismic walls
STUDY ON SEISMIC EFFECT OF HIGH RISE BUILDING SHEAR WALL/WALL WITHOUT SHEAR WALL
Performance of shear wall building during seismic excitations
Effect of steel bracing on vertically irregular r.c.c building frames under s...
Rc4 lecture 2- eng. samer akil
Study of lateral load resisting systems of variable heights in all soil types...

What's hot (19)

PDF
Coupling beams design كمرات وجوائز ربط بجدران القص
PDF
Performance of High-Rise Steel Building With and Without Bracings
PDF
Comparison of performance of lateral load resisting systems in multi storey f...
PDF
ANALYSIS OF SOFT STOREY FOR MULTI STORYED BUILDING IN ZONE-4
PDF
Use of flat slabs in multi storey commercial building situated in high seismi...
PPT
23576671 presentation
PDF
Linear Dynamic Analysis of Different Structural Systems for Medium Rise Buil...
PDF
Review paper on seismic responses of multistored rcc building with mass irreg...
PDF
Shear walls
PDF
Lec01 Design of RC Structures under lateral load (Earthquake Engineering هندس...
PDF
Dq32729732
PDF
ANALYSIS OF MOMENT RESISTING FRAME BY KNEE BRACING
PDF
Seismic study and performance of 30 storey high rise building with beam slab,...
PDF
Diagrid structure system - شبكات العقد الاطارية
PDF
effect of non seismic walls
PDF
STRUCTURAL COST COMPARISON OF LOW RISE BUILDING HAVING MOMENT RESISTING FRAME...
PDF
Parametric study of base isolated building
PPTX
Tensegrity
PDF
Lateral Load Analysis of Shear Wall and Concrete Braced Multi-Storeyed R.C Fr...
Coupling beams design كمرات وجوائز ربط بجدران القص
Performance of High-Rise Steel Building With and Without Bracings
Comparison of performance of lateral load resisting systems in multi storey f...
ANALYSIS OF SOFT STOREY FOR MULTI STORYED BUILDING IN ZONE-4
Use of flat slabs in multi storey commercial building situated in high seismi...
23576671 presentation
Linear Dynamic Analysis of Different Structural Systems for Medium Rise Buil...
Review paper on seismic responses of multistored rcc building with mass irreg...
Shear walls
Lec01 Design of RC Structures under lateral load (Earthquake Engineering هندس...
Dq32729732
ANALYSIS OF MOMENT RESISTING FRAME BY KNEE BRACING
Seismic study and performance of 30 storey high rise building with beam slab,...
Diagrid structure system - شبكات العقد الاطارية
effect of non seismic walls
STRUCTURAL COST COMPARISON OF LOW RISE BUILDING HAVING MOMENT RESISTING FRAME...
Parametric study of base isolated building
Tensegrity
Lateral Load Analysis of Shear Wall and Concrete Braced Multi-Storeyed R.C Fr...
Ad

Similar to Seismic Response of Structure with Single Core (20)

PDF
IRJET- Study on Shear Wall and Bracing in Irregular Structure and Regular Str...
PDF
IRJET- Comparative Study of Flat Slab and Conventional Slab Structure wit...
PDF
Effect of Wind Load on Structural Performance of Dimensionally Regular & Irre...
PDF
IRJET- Analysis of Various Effects on Multistory Building (G+27) by Staad Pro...
PDF
IIRJET-Comparison of Seismic Analysis of Multistoried Building with Shear Wal...
PDF
IRJET- Post Peak Response of Reinforced Concrete Frames with and without in F...
PDF
Seismic Behaviour of Reinforced Concrete Flat Plate Systems
PDF
ANALYSIS AND DESIGN OPTIMIZATION OF SHEAR-WALL IN CASE OF HIGH-RISE BUILDING ...
PDF
Seismic performance of friction pendulum bearing by considering storey drift ...
PDF
A Review on Analysis of a Tall Structure with Shear Panel and Floating Columns
PDF
IRJET- Effective Location of Shear Wall, its Significance and Displacement An...
PDF
Study of lateral load resisting systems of variable heights in all soil types...
PDF
IRJET- Comparative Study of Multi-Storey Building with Coupled Shear Wall...
PDF
STRUCTURAL COST COMPARISON OF LOW RISE BUILDING HAVING MOMENT RESISTING FRAME...
PDF
Significance of shear wall in flat slab multi storied building - A Review
PDF
Effect of Shear Wall on Overall Performance of Multi-Storey Buildings
PPTX
Thesis ppt (2).pptx this is for mtech student
PDF
Dynamic analysis of steel tube structure with bracing systems
PDF
IRJET- Study of Behaviour of Multi-Storey Building with Shear Walls
PDF
Seismic Analysis of Plan Irregular Multi-Storied Building with and without S...
IRJET- Study on Shear Wall and Bracing in Irregular Structure and Regular Str...
IRJET- Comparative Study of Flat Slab and Conventional Slab Structure wit...
Effect of Wind Load on Structural Performance of Dimensionally Regular & Irre...
IRJET- Analysis of Various Effects on Multistory Building (G+27) by Staad Pro...
IIRJET-Comparison of Seismic Analysis of Multistoried Building with Shear Wal...
IRJET- Post Peak Response of Reinforced Concrete Frames with and without in F...
Seismic Behaviour of Reinforced Concrete Flat Plate Systems
ANALYSIS AND DESIGN OPTIMIZATION OF SHEAR-WALL IN CASE OF HIGH-RISE BUILDING ...
Seismic performance of friction pendulum bearing by considering storey drift ...
A Review on Analysis of a Tall Structure with Shear Panel and Floating Columns
IRJET- Effective Location of Shear Wall, its Significance and Displacement An...
Study of lateral load resisting systems of variable heights in all soil types...
IRJET- Comparative Study of Multi-Storey Building with Coupled Shear Wall...
STRUCTURAL COST COMPARISON OF LOW RISE BUILDING HAVING MOMENT RESISTING FRAME...
Significance of shear wall in flat slab multi storied building - A Review
Effect of Shear Wall on Overall Performance of Multi-Storey Buildings
Thesis ppt (2).pptx this is for mtech student
Dynamic analysis of steel tube structure with bracing systems
IRJET- Study of Behaviour of Multi-Storey Building with Shear Walls
Seismic Analysis of Plan Irregular Multi-Storied Building with and without S...
Ad

More from ijtsrd (20)

PDF
A Study of School Dropout in Rural Districts of Darjeeling and Its Causes
PDF
Pre extension Demonstration and Evaluation of Soybean Technologies in Fedis D...
PDF
Pre extension Demonstration and Evaluation of Potato Technologies in Selected...
PDF
Pre extension Demonstration and Evaluation of Animal Drawn Potato Digger in S...
PDF
Pre extension Demonstration and Evaluation of Drought Tolerant and Early Matu...
PDF
Pre extension Demonstration and Evaluation of Double Cropping Practice Legume...
PDF
Pre extension Demonstration and Evaluation of Common Bean Technology in Low L...
PDF
Enhancing Image Quality in Compression and Fading Channels A Wavelet Based Ap...
PDF
Manpower Training and Employee Performance in Mellienium Ltdawka, Anambra State
PDF
A Statistical Analysis on the Growth Rate of Selected Sectors of Nigerian Eco...
PDF
Automatic Accident Detection and Emergency Alert System using IoT
PDF
Corporate Social Responsibility Dimensions and Corporate Image of Selected Up...
PDF
The Role of Media in Tribal Health and Educational Progress of Odisha
PDF
Advancements and Future Trends in Advanced Quantum Algorithms A Prompt Scienc...
PDF
A Study on Seismic Analysis of High Rise Building with Mass Irregularities, T...
PDF
Descriptive Study to Assess the Knowledge of B.Sc. Interns Regarding Biomedic...
PDF
Performance of Grid Connected Solar PV Power Plant at Clear Sky Day
PDF
Vitiligo Treated Homoeopathically A Case Report
PDF
Vitiligo Treated Homoeopathically A Case Report
PDF
Uterine Fibroids Homoeopathic Perspectives
A Study of School Dropout in Rural Districts of Darjeeling and Its Causes
Pre extension Demonstration and Evaluation of Soybean Technologies in Fedis D...
Pre extension Demonstration and Evaluation of Potato Technologies in Selected...
Pre extension Demonstration and Evaluation of Animal Drawn Potato Digger in S...
Pre extension Demonstration and Evaluation of Drought Tolerant and Early Matu...
Pre extension Demonstration and Evaluation of Double Cropping Practice Legume...
Pre extension Demonstration and Evaluation of Common Bean Technology in Low L...
Enhancing Image Quality in Compression and Fading Channels A Wavelet Based Ap...
Manpower Training and Employee Performance in Mellienium Ltdawka, Anambra State
A Statistical Analysis on the Growth Rate of Selected Sectors of Nigerian Eco...
Automatic Accident Detection and Emergency Alert System using IoT
Corporate Social Responsibility Dimensions and Corporate Image of Selected Up...
The Role of Media in Tribal Health and Educational Progress of Odisha
Advancements and Future Trends in Advanced Quantum Algorithms A Prompt Scienc...
A Study on Seismic Analysis of High Rise Building with Mass Irregularities, T...
Descriptive Study to Assess the Knowledge of B.Sc. Interns Regarding Biomedic...
Performance of Grid Connected Solar PV Power Plant at Clear Sky Day
Vitiligo Treated Homoeopathically A Case Report
Vitiligo Treated Homoeopathically A Case Report
Uterine Fibroids Homoeopathic Perspectives

Recently uploaded (20)

PDF
STATICS OF THE RIGID BODIES Hibbelers.pdf
PDF
Basic Mud Logging Guide for educational purpose
PPTX
PPH.pptx obstetrics and gynecology in nursing
PDF
The Lost Whites of Pakistan by Jahanzaib Mughal.pdf
PDF
Pre independence Education in Inndia.pdf
PDF
Black Hat USA 2025 - Micro ICS Summit - ICS/OT Threat Landscape
PDF
Abdominal Access Techniques with Prof. Dr. R K Mishra
PPTX
1st Inaugural Professorial Lecture held on 19th February 2020 (Governance and...
PPTX
Institutional Correction lecture only . . .
PDF
Microbial disease of the cardiovascular and lymphatic systems
PDF
FourierSeries-QuestionsWithAnswers(Part-A).pdf
PDF
Insiders guide to clinical Medicine.pdf
PPTX
master seminar digital applications in india
PDF
3rd Neelam Sanjeevareddy Memorial Lecture.pdf
PDF
Supply Chain Operations Speaking Notes -ICLT Program
PPTX
Cell Structure & Organelles in detailed.
PDF
102 student loan defaulters named and shamed – Is someone you know on the list?
PDF
BÀI TẬP BỔ TRỢ 4 KỸ NĂNG TIẾNG ANH 9 GLOBAL SUCCESS - CẢ NĂM - BÁM SÁT FORM Đ...
PDF
2.FourierTransform-ShortQuestionswithAnswers.pdf
PDF
Computing-Curriculum for Schools in Ghana
STATICS OF THE RIGID BODIES Hibbelers.pdf
Basic Mud Logging Guide for educational purpose
PPH.pptx obstetrics and gynecology in nursing
The Lost Whites of Pakistan by Jahanzaib Mughal.pdf
Pre independence Education in Inndia.pdf
Black Hat USA 2025 - Micro ICS Summit - ICS/OT Threat Landscape
Abdominal Access Techniques with Prof. Dr. R K Mishra
1st Inaugural Professorial Lecture held on 19th February 2020 (Governance and...
Institutional Correction lecture only . . .
Microbial disease of the cardiovascular and lymphatic systems
FourierSeries-QuestionsWithAnswers(Part-A).pdf
Insiders guide to clinical Medicine.pdf
master seminar digital applications in india
3rd Neelam Sanjeevareddy Memorial Lecture.pdf
Supply Chain Operations Speaking Notes -ICLT Program
Cell Structure & Organelles in detailed.
102 student loan defaulters named and shamed – Is someone you know on the list?
BÀI TẬP BỔ TRỢ 4 KỸ NĂNG TIẾNG ANH 9 GLOBAL SUCCESS - CẢ NĂM - BÁM SÁT FORM Đ...
2.FourierTransform-ShortQuestionswithAnswers.pdf
Computing-Curriculum for Schools in Ghana

Seismic Response of Structure with Single Core

  • 1. International Journal of Trend in Scientific Research and Development (IJTSRD) Volume 4 Issue 3, April 2020 Available Online: www.ijtsrd.com e-ISSN: 2456 – 6470 @ IJTSRD | Unique Paper ID – IJTSRD30851 | Volume – 4 | Issue – 3 | March-April 2020 Page 1131 Seismic Response of Structure with Single Core Belsare Sumit Bandopanth1, Dilip Budhlani2 1M.Tech Student, 2Assistant Professor, 1,2Department of Civil Engineering, GNIT, Nagpur, Maharashtra, India ABSTRACT Shear walls and outriggers have been used so far to resist theseismicwavesof earthquake and heavy winds actions. The complete failure of the structures that has occurred in the past due to catastrophic earthquake may be avoided with the use of shear wall in the structure. The studyisconcernedwiththeuse of shear wall as a single core in structure that will resist the seismic waves of earthquake. In the present study analysis of RCC buildinghasbeencarriedout by changing the locations of shear walls in the building. The seismic analysis performed is linear dynamic response spectrum analysis using the well- known analysis and design softwareETABS16.2.0.Seismicperformanceofthe building has been investigated based on parameterssuchasstroreydrift, base shear and storey displacement. KEYWORDS: Shear walls, Outriggers, Single Core How to cite this paper: Belsare Sumit Bandopanth | Dilip Budhlani "Seismic Response of Structure with Single Core" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456- 6470, Volume-4 | Issue-3, April 2020, pp.1131-1136, URL: www.ijtsrd.com/papers/ijtsrd30851.pdf Copyright © 2020 by author(s) and International Journal ofTrendinScientific Research and Development Journal. This is an Open Access article distributed under the terms of the Creative CommonsAttribution License (CC BY 4.0) (http://creativecommons.org/licenses/by /4.0) 1. INTRODUCTION The Displacement of a tall building caused by horizontal forces due to wind or earthquake can be reduced by the provision of core. The core is the main lateral force-resistant component. The maximum horizontal displacement is limited by codes for the stability of the building and for the comfort of its occupants. Also,thecodeslimittheinterstorey drift ratio, defined as the difference of drift in two consecutive floors divided by the vertical distance between them. The sum of the moments at the ends of a column at a floor level is a couple transferred, in the opposite direction, to the floor; the floor must be designed for the flexural and shear stress caused by the transfer. The moments transferred between the columns and the floors are mainly dependent on the inter storey drift ratio. The primary purpose of different types of structural system in buildings is to resist gravity loads like dead, live loads. Besides these vertical loads, lateral loads caused by wind, earthquake also acts on buildings. It is very important that structure should resist both vertical loads and lateral loads. The shear wall-frame system is the most commonly used structural system in reinforced concrete buildings to counteract the effect of both gravity and horizontal loads. These shear wall-frame system have high lateral resistance against horizontal loads by placing shear walls in an advantageous location in the plan of building. Shear Wall Shear walls are vertical reinforced concrete structural elements to resist both gravityandlateral loadsactingonthe structure. The thickness of wall varies from 200 to 500mm, depends on the height of the building and seismic zone of building area. They are different types of shear walls in building system 1) simple rectangulartypeandflangedwalls 2) coupled shear wall 3) core type shear wall. The simple rectangular wall is generally placed between periphery columns of building and core walls are placed around the staircase and elevator to resist the vibration loads and lateral loads. In the present study core wall are included in the building frame. Normally the civil engineeringstructures are designed within the elastic range, but under a strong seismic event, a structure may really be subjected to forces past its flexible breaking point. In spite of the fact that construction laws can give a dependable sign of real execution of individual structural components, it is out of their extension to depict the normal execution of planned structure as a whole, under huge forces. A few businesses, for example, car and flight, routinely construct full-scale models and perform broad testing,beforeassemblinga large number of indistinguishable structures, that have been examined and composed with the thought of test outcomes. Unfortunately, this choice is not accessible to building industry as because of the uniqueness of normal individual structures, the economy of substantial scale creation is unachievable. IJTSRD30851
  • 2. International Journal of Trend in Scientific Research and Development (IJTSRD) @ www.ijtsrd.com eISSN: 2456-6470 @ IJTSRD | Unique Paper ID – IJTSRD30851 | Volume – 4 | Issue – 3 | March-April 2020 Page 1132 Figure 1 Types of shear walls Outriggers Although outriggers have been used for approximately four decades, their existence as a structural member has a much longer history. Outriggers have been used in the sailing ship industry for many years. They are used to resist wind. The slender mast provides the use ofoutriggers.Asa comparison the core can be related to the mast, the outriggers are like the spreaders and the exterior columns are like the shrouds or stays. Innovative structural schemes are continuously being sought in the field. Structural Design of High-Rise Structures with the intention of limiting the Drift due to Lateral Loads to acceptable limits without paying a high premium in steel tonnage. The savings in steel tonnage and cost can be dramatic if certain techniques are employed to utilize the full capacities of the structural elements. Various wind bracing techniques havebeendevelopedinthisregard; one such is an Outrigger System, in which the axial stiffness of the peripheral columns is invoked for increasing the resistance to overturning moments. This efficient structural form consists of a central core, comprising either Braced Frames or Shear Walls, with horizontal cantilever trusses or girders known as outrigger Trusses, connecting the core to the outer columns. The core may be centrally located with outriggers extending on both sides (Fig.2.a) or it may be located on one side of the building withoutriggersextending to the building columns on one side (Fig.2.b). Fig.2 (a) Outrigger system with a central core (b) Outrigger system with offset core When Horizontal loading acts on the building, the column restrained outriggers resist the rotation of the core, causing the lateral deflections and moments in the coretobesmaller than if the free-standing core alone resisted the loading. The result is to increase the effective depth ofthestructurewhen it flexes as a vertical cantilever, by inducing tension in the windward columns and Compression in the leeward columns. In addition to those columns located at the ends of the outriggers, it is usual to also mobilize other peripheral columns to assist in restraining the outriggers. This is achieved by including a deep Spandrel Girder, or a Belt Truss, around the structure at the levels oftheoutriggers. To make the Outriggers and Belt Truss adequately stiff in flexure and shear, they are made at least one, and often 2 – stories deep. It is also possible to use diagonals extending through several floors to act as outriggers. And finally, girders at each floor may be transformed into outriggers by moment connections to the core and, if desired, to the exterior columns as well. Here, it should be noted that while the outrigger system is very effective in increasing the structure’s flexural stiffness,itdoesn’tincreaseitsresistance to shear, which has to be carried mainly by the core. (C) Fig.3 Diagonals acting as outriggers 2. CASE STUDY Study is carried out by ModelingoftheG+20storeybuildings with core shear wall and braced core at center, corner and side in ETABS 2016. During the analysis various IS codes have been adopted such as IS: 456 for concrete design, IS: 875 for loads, IS: 800 for steel design, IS: 1893-2016 for seismic design. The seismic effect on the structure has been studied using responsespectrummethodandcorresponding various parameters has been tabulated. The main seismic parameters that are compared are maximum displacement, storey drift,baseshear,timeperiod and axial force and moments in columns. The following various parameters were considered for modelling and Analysis of the structure in ETABS. Building Plan and its Geometry The plan area of the building is kept 21 m x 21 m. Height of each storey is kept uniform i.e. 3 m. so the total height of the building is 63m. Number of bay in x direction is 5 and Number of bay in y direction is 5, the bay widthinxdirection is 4.2 m, the bay width in y direction is 4.2m. Various type of structural model considered for this study. Model 1- Symmetric plan frame without center core. Model 2- Symmetric plan frame without corner core. Model 3- Symmetric plan frame without side core. Model 4- Symmetric plan frame with center shear wall (SW) core. Model 5- Symmetric plan frame with corner shear wall (SW) core. Model 6- Symmetric plan frame with side shear wall (SW) core.
  • 3. International Journal of Trend in Scientific Research and Development (IJTSRD) @ www.ijtsrd.com eISSN: 2456-6470 @ IJTSRD | Unique Paper ID – IJTSRD30851 | Volume – 4 | Issue – 3 | March-April 2020 Page 1133 Model 7- Symmetric plan frame with centerbraced(BR) core. Model 8- Symmetric plan framewithcorner braced(BR) core. Model 9- Symmetric plan frame with side braced (BR) core. Model 10- Asymmetric plan frame without center core. Model 11- Asymmetric plan frame without corner core. Model 12- Asymmetric plan frame without side core. Model 13- Asymmetric plan frame with center shear wall (SW) core. Model 14- Asymmetric plan frame with corner shear wall (SW) core. Model 15- Asymmetric plan frame with side shear wall (SW) core. Model 16- Asymmetric plan frame with center braced (BR) core. Model 17- Asymmetric plan frame with corner braced (BR) core. Model 18- Asymmetric planframewithside braced(BR) core. Model 19- AsymmetricL planframewithoutcentercore. Model 20- Asymmetric L plan frame without corner core. Model 21- Asymmetric L plan frame without side core. Model 22- Asymmetric L plan frame with center shear wall (SW) core. Model 23- Asymmetric L plan frame with corner shear wall (SW) core. Model 24- Asymmetric L plan framewithsideshear wall (SW) core. Model 25- Asymmetric L plan frame with center braced (BR) core. Model 26- Asymmetric L plan frame with corner braced (BR) core. Model 27- Asymmetric L plan frame with side braced (BR) core. Material properties Concrete of grade M35, steel grade of Fe 345 and Rebar of grade Fe500 is used for modeled the building. The poison’s ratio for concrete and steel is taken as 0.3. The density of concrete is 25kN/m³ and density of brick masonry is 20 KN/m3 is considered for modeled the building. Member dimensions The dimensions of members are decided by observing the stability aspect table 1 shows thememberdimensionswhich have used in all models of building. Table 1 Member Dimensions Member Size Thickness of RCC Slab 150 mm Beam Size 230 mm x 500 mm Column Size 600 mm x 600 mm Thickness of Brick Masonry wall 230 mm Thickness of RCC Shearwall 250 mm Steel Outriggers ISA 150 x 150 x 15 mm Load details Following are the details of loads which has considered in this analysis and design of Building. A. Dead load: - In ETABS the software itself calculates the dead loads by applying a self-weightmultiplierfactorof one which is taken by the structure and the rest load cases are kept zero. Its defined in the load patterns section. B. Live load on floors: - 2.5 KN/m² as per IS:875 (part -2). C. Live load on roof: - 1.5 KN/m² as per IS:875 (part -2). D. Wall load on all levels: - 3 x 0.23 x 20 = 11.5 KN/m. Seismic Data Zone Factor: - Zone III (0.16) Importance factor: - 1.2 (Residential building with occupancy more than 200 persons) Response Reduction Factor: - 5 Special moment resisting frame (SMRF) Soil Type: - II Medium Damping Ratio: - 5% Load Combinations Each model of the building is subjected to Dead Load, Live Load and Seismic Forces in – (+) X and (-) X Direction (+) Y and (-) Y Direction After applying above load each model of the building is analyzed for dynamic method under the following load combination generated automatically using ETABS: - 1.5 x [DL-Self Weight] 1.5 x [DL + LL] 1.2 x [DL + LL + EQX] 1.2 x [DL + LL - EQX] 1.2 x [DL + LL + EQX-] 1.2 x [DL + LL – EQX-] 1.2 x [DL + LL + EQY] 1.2 x [DL + LL - EQY] 1.2 x [DL + LL + EQY-] 1.2 x [DL + LL – EQY-] 1.5 x [DL + EQX] 1.5 x [DL - EQX] 1.5 x [DL + EQX-] 1.5 x [DL - EQX-] 1.5 x [DL + EQY] 1.5 x [DL - EQY] 1.5 x [DL + EQY-] 1.5 x [DL - EQY-] 0.9 DL + 1.5 EQX 0.9 DL - 1.5 EQX 0.9 DL + 1.5 EQX- 0.9 DL - 1.5 EQX- 0.9 DL + 1.5 EQY 0.9 DL - 1.5 EQY 0.9 DL + 1.5 EQY 0.9 DL - 1.5 EQY 3. METHODOLOGY OF PROPOSED WORK A. Modeling of the twenty storey buildings with coreshear wall and braced core at center, corner and side in ETABS. B. Application of gravity loads (dead, live, wall load) asper Indian codes and lateral loadsasperIS1893:2002. Since the live load class is up to 3 KN/m2, 25% of the imposed load has been considered. C. Analyzing the building using Response spectrum analysis with fixed support. D. Comparing the results of building models.
  • 4. International Journal of Trend in Scientific Research and Development (IJTSRD) @ www.ijtsrd.com eISSN: 2456-6470 @ IJTSRD | Unique Paper ID – IJTSRD30851 | Volume – 4 | Issue – 3 | March-April 2020 Page 1134 4. MODELLING General In this study, total twenty-seven models are considered to perform the seismic analysis. All the models having 20 stories and height of each storey was 3m. First nine models are in the square plan of 21m x 21m with 5 bays on eachside and the next eighteen models are asymmetric in plan. In all the models the lateral loads are resisted by withandwithout single core (SW & BR) with varying position of core. Response spectrum method of seismicanalysisiscarried out as per IS 1893:2016. Modeling and analysis are done in ETABS software. Response Spectrum Analysis Earthquake engineers preferred to report an interaction between the acceleration of ground and structural system through response spectrum first proposed by Biot and later popularized by Housner. A Response spectrum is a plot of the maximum response of a set ofSDOF systemssubjected to ground motion as ordinate and corresponding time periods of the SDOF system as abscissa. This methodisapplicable for those structures where modes other than the basic mode that influences the structure reaction. In this method the Multi-degree-of-Freedom (MDOF) system response is expressed as the superposition of modal response, by the spectral analysisofsingle-degree-of-freedom(SDOF)system, the response of each mode beingdetermined, whicharethen combined to find out the total response. Methods of combining modal response: A. Absolute – peak values are added together B. Square root of the sum of the squares (SRSS) C. Complete quadratic combination (CQC) Fig.4 Response Spectrum Curve Building Models Fig.5 Model 1- Symmetric plan frame without center core Fig.6 Model 2- Symmetric plan frame without corner core Fig.7 Model 3 - Symmetric plan frame without side core Fig.8 Model 4 - symmetric plan frame with center shear wall (SW) core. Fig.9 Model 5 - symmetric plan frame with corner shear wall (SW) core.
  • 5. International Journal of Trend in Scientific Research and Development (IJTSRD) @ www.ijtsrd.com eISSN: 2456-6470 @ IJTSRD | Unique Paper ID – IJTSRD30851 | Volume – 4 | Issue – 3 | March-April 2020 Page 1135 Fig. 10 Model 6 - symmetric plan frame with side shear wall (SW) core. Fig. 11 Model 10 – Asymmetric plan frame without center core. Fig.12 Model 11 -Asymmetric plan frame without corner core. Fig.13 Model 12 - Asymmetric plan frame without side core. Fig.14 Model 13 - Asymmetric plan frame with center shear wall (SW) core Fig.15 Model 14 - Asymmetric plan frame with corner shear wall (SW) core Fig. 16 Model 15 - Asymmetric plan frame with side shear wall (SW) core. Fig.17 Model 19 - Asymmetric L plan frame without center core.
  • 6. International Journal of Trend in Scientific Research and Development (IJTSRD) @ www.ijtsrd.com eISSN: 2456-6470 @ IJTSRD | Unique Paper ID – IJTSRD30851 | Volume – 4 | Issue – 3 | March-April 2020 Page 1136 Fig.18 Model 20 - Asymmetric L plan frame without corner core. Fig.19 Model 21 - Asymmetric L plan frame without side core. Fig.20 Model 22 - Asymmetric L plan frame with center shear wall (SW) core. Fig.21 Model 23 - Asymmetric L plan frame with Corner shear wall (SW) core. Fig.22 Model 24 - Asymmetric L plan frame with side shear wall (SW) core. 5. CONCLUSION Satisfying the requirement of the stability conditions for a single core structure will becomplicatedone,comparedwith the structures supported in all sides depending upon their configuration. Single core structureisa critical onewhenitis subjected to unsymmetrical and eccentric loading conditions. Eccentric loading will causethestructuretotwist in any direction and may cause failure of structure. By the study, we want to explore a new dimension of the existing construction techniques. This study describes planning, structural analysis and design of the single core building. The Buildings with single core at corner and side position tends to go in Torsion Mode which develops extra forces in the frames. Greater Economy can be achievedbykeepingthe single Cores at Centre of the Buildings. Building at center core will gives economical design as well as sufficient amount of safety. 6. REFERENCE [1] IS: 1893 PART 1 (2016) “Criteria for Earthquake Resistant Design of Structures– general provisionsand buildings” Bureau of Indian Standards, New Delhi. [2] Jibi Abraham “Seismic Analysis Of Pyramid Shaped Building With And Without Bracing” , published in International Research Journal of Engineering and Technology (IRJET) Volume: 05 Issue: 05 | May-2018, ISSN: 2395-0056 [3] Maikesh Chouhan, ‘Dynamic AnalysisofMulti-Storeyed Frame-Shear Wall Building Considering SSI’, published in International Journal of Engineering Research and Application Vol. 6, Issue 8, ( Part -1) August 2016, pp.31-35 www. ijera.com ISSN : 2248-9622 [4] Pavan Kumar, ‘Earthquake Analysis of Multi Storied Residential Building - A Case Study’, published in International Journal of Engineering Research and Applications www.ijera.com, Vol. 4, Issue 11( Version 1), November 2014, pp.59-64, ISSN : 2248-9622 [5] Abrar Ahmed, ‘Seismic Analysis On Building With Horizontal And Vertical Irregularities’, published in International Journal of Advance Engineering and Research Development Volume 4, Issue 9, September - 2017