OVERVIEW
In January 2006 I joined the laboratory of Dr. Stephen
Helms Tillery, who only months before had accepted a
tenure track position in the department of
Bioengineering at Arizona State University. Our goal
was to build a laboratory to conduct world-class
research into the neural basis of sensor and motor
function in the brain.

The opportunity was rare and exciting, but we truly started from scratch. My first glimpse of the
lab was of completely empty room. The Boss told me what he wanted and said, “Build it.”

MY ROLE
This was my most complex and comprehensive accomplishment to date. I was responsible for
procurement, installation, configuration, software development, and hardware development for
everything in the lab. I was given broad budgetary discretion for purchases. If something was
required and it didn’t exist, I designed it in Solidworks then fabricated it with machine tools or
rapid prototyping machines. If software was required, I developed it in C/C++, Python, Matlab,
Simulink, etc... Over the next 2 years the following core pieces of the laboratory setup were
developed:


   1. 6-AXIS INDUSTRIAL ROBOT: A robot arm was required to present objects to research
      subjects. Developed custom real-time control routines in C++ using manufacturer SDK.
      Integrated pneumatic end effector tool changer system with 6-DoF Force/Torque
      sensor. Developed custom front end GUI using LabView.

   2. VIRTUAL REALITY SIMULATION: Our experiments required subjects to execute tasks in a
      virtual reality environment. This was developed in the Python programming language in
      using Vizard development software. VR control was integrated into overall system using
      LabView.

   3. 3-D MOTION CAPTURE: We tracked and analyzed the detailed kinematics of our subjects’
      hand during the experimental task using an active marker (LED) system from
      Phasespace. Developed custom marker arrays and core software routines to acquire
      maker data in real time to drive animations in the VR simulation.

   4. NEUROPHYSIOLOGICAL RECORDING SETUP: We recorded the activity of single neurons in
      the sensory cortex of the brain during our experiments. The Plexon system was
      integrated in the overall system using LabView software
5. SYSTEM CONTROL SOFTWARE: Developed a hybrid PC/Real-Time application in LabView
      to unify all components of the system, including sensory I/O, robot commands and VR
      control. The end product was a unified control GUI from which all aspects of the
      experiment could be monitored and controlled.

   6. MONKEYS!!: Truly the most unpredictable and challenging aspect of the this work; an
      education within an education. Learned to handle, train and work with two male Rhesus
      macaque monkeys to obtain neurophysiological data.


OUTCOME

After nearly four and a half years of continuous work, I completed my experimental work and
doctoral dissertation, graduating in May of 2010. My legacy is a neurophysiological recording
laboratory that is uniquely capable, flexible and reconfigurable for many kinds of neural
experimentation protocols.


Accomplishing the PhD made me a better engineer and taught me how to carry out research.
What I now seek is the opportunity to unify the myriad skills acquired in my work and education
so far into a single goal requiring multidisciplinary skills.
EXPERIMENTAL SETUP




  1. Monkeys were trained in a novel Reach-to-Grasp task in which all visual cues were
     presented in a Virtual Reality simulation.

  2. Grasp object of different sizes were presented in the workspace behind the VR
     presentation and hand position and digit kinematics were tracked using an active
     marker motion capture system.

  3. The firing activity of single neurons in sensory cortex was recorded while the monkeys
     completed either a physical task (object present in the workspace) or a randomly
     inserted virtual task (object presented just out of reach)

  4. This approach permitted manipulation of the actual and expected sensory outcome of
     the task.
SMORG ROBOT AND ASSOCIATED HARDWARE.

      A                                                                   b3
                                                                                         B

                                                          b2


                                                            b1




                                                                                         C




A. THE 6-AXIS INDUSTRIAL ROBOT. Mounted on a custom platform and controlled using custom
software. Dedicated signal and air channels routed through the robot enabled feedback from a
6-DOF F/T sensor, object touch sensors and control of a pneumatic tool changer.

B. THE ROBOT END EFFECTOR. The F/T sensor (b2) was mounted directly to the robot end
effector (b1). The master plate of the tool changer (b3) was mounted to the F/T sensor using a
custom interface plate. Air lines originating from ports on the robot controlled the locking
mechanism of the master plate.

C. GRASP OBJECT ASSEMBLY. The object was mounted to a six-inch standoff post that mounted
to a tool plate. Touch sensors were mounted flush with the object surface and wires were
routed to the object interior for protection. Power and signal lines were routed through a pass-
through connector (not visible), through the robot interior to an external connector on the robot
base.
CAPTURING HAND KINEMATICS.


    A                              B                                                           C




                                   D




Our experiments required knowledge of detailed hand kinematics – of monkeys! This figure
highlights just some of the hardware and electronics development I conducted to accomplish
this task.

A. COMMERCIALLY AVAILABLE DATA GLOVES feature numerous integrated bend sensors to
capture the posture of the digits and palm but were prohibitively expensive and difficult to
customize to the monkey hand.

B. EARLY PROTOTYPE OF THE CUSTOM MONKEY GLOVE. Bend sensors and electronics were
removed from a gaming glove and reconfigured to the monkey hand.

C. A WIRELESS VERSION OF THE MONKEY GLOVE. This more advanced version featured 5 bend
sensors, 2-axis roll/pitch sensing, wireless bluetooth transmisstion and a rechargeable battery.
Electronics were encased in epoxy for protection.

D. AN ALTERNATIVE STRATEGY FOR PASSIVE MOTION CAPTURE. Cube
markers with finger attachment clips were developed to utilize larger
markers for a novel camera sensing technique. This approach
captured only crude measures of hand posture




ACTIVE MARKER LEDS. We eventually settled on an active marker
LED system from Phasespace, show at right.
GENERAL SMORG LAB PICTURES

                                                TESTING ROOM Motion
                                                capture cameras
                                                surround the subject
                                                seating area. A 3D
                                                monitor placed
                                                overhead reflects the
                                                VR environment into a
                                                mirror directly ahead.
                                                The robot presented
                                                grasp objects in the
                                                workspace




HARDWARE AND ELECTRONICS These experiments
required the integration of much hardware and
electronics




CUSTOM HARDWARE These experiments also
required the development of custom hardware,
such as the grasp objects seen here.
PROJECT: Experimental Device Development

PRODUCT: Actuated Ankle Foot Orthosis (AAFO)

ROLE:        Project Manager


OVERVIEW
Advensys, LLC is an early stage startup company developing
adaptive neuromorphic systems for “advancing human
mobility.” In 2004 the company was awarded a competitive
Phase I contract by the US Army to develop a
neuromorphically controlled lower leg orthosis capable of
providing ambulatory support for soldiers with injuries
sustained in combat. The company was tasked with
developing a prototype electronic control system based on
neural pattern networks, management of AAFO hardware
development and experimental assessment of the integrated
system. The duration of Phase I prototype development,
integration and testing was just 6 months.

MY ROLE
I was hired by the President and co-founder of the company
as the Program Manager. My duties included several
significant subtasks of the overall project:

   7. NUMERICAL MODELING OF NEURAL PATTERN GENERATOR NETWORK: a biologically inspired
      oscillating signal generator patterned after spinal locomotor circuitry of the lamprey. The
      activity of this network could be entrained by an external periodic signal and would form
      the basis of our real-time control system.

   8. PROTOTYPE ELECTRONICS DEVELOPMENT: Following numerical simulation and
      characterization, the neural pattern generator was implemented in breadboard
      electronics using RC circuit models of neural membrane dynamics.

   9. REAL-TIME CONTROL SYSTEM DEVELOPMENT: A real-time numerical controller was
      developed using Matlab, Simulink and Real-Time Workshop. The controller was driven
      by a hip angle sensor and drove the ankle “push-off” of the AAFO.


OUTCOME

Phase I was completed on time and under budget. The device was demonstrated to senior
Army program officials in a live demonstration and feedback was overwhelmingly positive.

Advensys was invited to apply for Phase II funding, and was subsequently awarded
approximately $1.5 million over 2 years.
NUMERICAL MODELING OF NEURAL PATTERN GENERATOR NETWORK

                                               THE UNIT PATTERN GENERATOR
                                               (UPG) CONCEPT: A bi-laterally
                                               symmetric network whose
                                               connectivity is based on the
                                               known architecture of the
                                               lamprey spinal cord. The three
                                               spinal neural classes that form
                                               the kernel of the uPG are: E-
                                               excitatory, L-inhibitory, and C-
                                               crossed inhibitory. The E, L,
                                               and C neurons represent the
                                               core of the network and the M
                                               neurons are the “output” units
                                               of the network.




SIMULATION RESULTS OF NEURAL
NETWORK ENTRAINMENT IN RESPONSE
TO INJECTED CURRENT INPUT. Both
sides of the network oscillate at
default frequency before entrainment,
and then assume the frequency of
the injected current.
PROTOTYPE ELECTRONICS DEVELOPMENT

                                    PROTOTYPE UNIT PATTERN
                                    GENERATOR (UPG)
                                    ELECTRONICS: Unit Pattern
                                    Generator network showing
                                    neurons implemented in
                                    analog hardware.




ELECTRONICS TESTING:
uPG network testing
REAL-TIME CONTROL SYSTEM DEVELOPMENT




                                                                                         !

CONTROL SYSTEM DEVELOPMENT: Simulation and controller development were in Matlab,
Simulink and Real-Time Workshop (RTW). Compiled, executable RTW code was ported to the
Hardware Computer via an ethernet link. The Hardware Computer executed the real-time
control system code, including sampling analog sensor input (analog-to-digital) from external
hardware and asserting all analog commands (digital-to-analog) to hardware through the PCI
DAS1200 A/D, D/A card. Two Break-Out Boards (BOB) provided numbered conductor
connection points for system I/O. Motor commands, were sent from the BOB to the Amplifier
Board, which directly drove the motor.

More Related Content

PDF
Kohlbecker Low Latency Combined Eye And Head Tracking System For Teleoperatin...
PPTX
Neurobotix LTD Proposal
PPTX
Becoming a kinect hacker innovator v2
PPTX
Kinectic vision looking deep into depth
PPTX
Turning Augmented/Virtual Reality hype Into Actual Reality
PPTX
Kinect sensor
PDF
Hand Gesture Interface 기술동향 및 전망
PPTX
Kinect
Kohlbecker Low Latency Combined Eye And Head Tracking System For Teleoperatin...
Neurobotix LTD Proposal
Becoming a kinect hacker innovator v2
Kinectic vision looking deep into depth
Turning Augmented/Virtual Reality hype Into Actual Reality
Kinect sensor
Hand Gesture Interface 기술동향 및 전망
Kinect

What's hot (7)

PDF
Emotiv epoc introduction
PPTX
Kinect for Xbox 360: the world's first viral 3D technology
PPT
Kinect krishna kumar-itkan
DOCX
Project soli
PDF
Project soli technical seminar
PPTX
Kinect
PDF
Making Immersive Virtual Reality Possible in Mobile
Emotiv epoc introduction
Kinect for Xbox 360: the world's first viral 3D technology
Kinect krishna kumar-itkan
Project soli
Project soli technical seminar
Kinect
Making Immersive Virtual Reality Possible in Mobile
Ad

Viewers also liked (18)

PPT
1 introduccion
PPTX
GHS PTSA After Prom 2013 Presentation
PDF
Building the SMoRG Lab
PPTX
How the EU takes decisions
PPT
PDF
ATIC Annual Report 2011
PPTX
PDF
Meller et al (2012) Single Unit Firing Rates In Macaque SI (In Review)
PPTX
Best friends forever
PPT
Lizelle anne
PPTX
Have you washed your hands lately
PPT
Christmas in austria (ii)
PDF
Ncfm security markets
PPT
Christmas in Sweden
1 introduccion
GHS PTSA After Prom 2013 Presentation
Building the SMoRG Lab
How the EU takes decisions
ATIC Annual Report 2011
Meller et al (2012) Single Unit Firing Rates In Macaque SI (In Review)
Best friends forever
Lizelle anne
Have you washed your hands lately
Christmas in austria (ii)
Ncfm security markets
Christmas in Sweden
Ad

Similar to Selected Work Portfolio (20)

PDF
COMP 4010 Lecture6 - Virtual Reality Input Devices
PDF
COMP 4010 Lecture 3 VR Input and Systems
PPTX
Final_Presentation_RoboticsClub
PDF
A Mimicking Human Arm with 5 DOF Controlled by LabVIEW
PDF
426 Lecture 9: Research Directions in AR
PDF
Comp4010 Lecture9 VR Input and Systems
PPTX
Presentation Selan dos Santos 4Eyes Lab
PDF
COMP 4010 - Lecture 3 VR Systems
ODP
Mid review presentation
PDF
Automation of wheel chair using ultrasonics and kinematics03
PDF
Bri503 lecture05
PPTX
Mid review presentation
PDF
PhillipDaniel_Full_Portfolio
PDF
Aquila: An Open-Source GPU-Accelerated Toolkit for Cognitive and Neuro-Roboti...
PPTX
Inform- interacting with a dynamic shape display
PDF
IEM ECE Electrovision 2013
PDF
Experiences in the Creation of an Electromyography Database to Help Hand Ampu...
PPTX
Haptic Technology ppt
PPT
Jennie sinsfadp06
COMP 4010 Lecture6 - Virtual Reality Input Devices
COMP 4010 Lecture 3 VR Input and Systems
Final_Presentation_RoboticsClub
A Mimicking Human Arm with 5 DOF Controlled by LabVIEW
426 Lecture 9: Research Directions in AR
Comp4010 Lecture9 VR Input and Systems
Presentation Selan dos Santos 4Eyes Lab
COMP 4010 - Lecture 3 VR Systems
Mid review presentation
Automation of wheel chair using ultrasonics and kinematics03
Bri503 lecture05
Mid review presentation
PhillipDaniel_Full_Portfolio
Aquila: An Open-Source GPU-Accelerated Toolkit for Cognitive and Neuro-Roboti...
Inform- interacting with a dynamic shape display
IEM ECE Electrovision 2013
Experiences in the Creation of an Electromyography Database to Help Hand Ampu...
Haptic Technology ppt
Jennie sinsfadp06

Recently uploaded (20)

PPTX
430838499-Anaesthesiiiia-Equipmenooot.pptx
PPTX
CIRCULATION-WPS Office hijghi gjjgfty.pptx
PPTX
Gender Sensitizations and females learning
PDF
Acne presentation and homeopathy treatment
PPT
ppt-of-extraction-of-metals-12th-1.pptb9
PPTX
Coordination Compuch flasks didiinds.pptx
PPTX
obstetric instruments for final year mbbs students
PPTX
DiagdndigsbskshsvsjsisDiarrheal Diseases-1.pptx
PPTX
Unit 3 Presentation Etiquette Business and Corporate Etiquette
PDF
202s5_Luciano André Deitos Koslowski.pdf
PPTX
GPAT Presentation PPT and details about imp topics.pptx
PDF
IMPORTANT QUES CLASS 12.pdf english by Tania sharma
PPTX
The Schools Division Office of Davao del Sur humbly requests for the approval...
PPTX
Creating-a-Personal-Blockchain-Portfolio-for-Developers-and-Experts.pptx
PPTX
ChandigarhUniversityinformationcareer.pptx
PDF
Environmental-social-and-governance-report.pdf
PPT
Woman as Engineer and Technicians in the field of Clinical & Biomedical Engin...
PPTX
Final Second DC Messeting PPT-Pradeep.M final.pptx
PPTX
Digital Education Presentation for students.
PDF
Result-BAMS-4th-Year-2016-Onwards-May-June-2025.pdf
430838499-Anaesthesiiiia-Equipmenooot.pptx
CIRCULATION-WPS Office hijghi gjjgfty.pptx
Gender Sensitizations and females learning
Acne presentation and homeopathy treatment
ppt-of-extraction-of-metals-12th-1.pptb9
Coordination Compuch flasks didiinds.pptx
obstetric instruments for final year mbbs students
DiagdndigsbskshsvsjsisDiarrheal Diseases-1.pptx
Unit 3 Presentation Etiquette Business and Corporate Etiquette
202s5_Luciano André Deitos Koslowski.pdf
GPAT Presentation PPT and details about imp topics.pptx
IMPORTANT QUES CLASS 12.pdf english by Tania sharma
The Schools Division Office of Davao del Sur humbly requests for the approval...
Creating-a-Personal-Blockchain-Portfolio-for-Developers-and-Experts.pptx
ChandigarhUniversityinformationcareer.pptx
Environmental-social-and-governance-report.pdf
Woman as Engineer and Technicians in the field of Clinical & Biomedical Engin...
Final Second DC Messeting PPT-Pradeep.M final.pptx
Digital Education Presentation for students.
Result-BAMS-4th-Year-2016-Onwards-May-June-2025.pdf

Selected Work Portfolio

  • 1. PROJECT: Neural Recording Laboratory PRODUCT: Research Laboratory ROLE: Architect/Doctoral Researcher OVERVIEW In January 2006 I joined the laboratory of Dr. Stephen Helms Tillery, who only months before had accepted a tenure track position in the department of Bioengineering at Arizona State University. Our goal was to build a laboratory to conduct world-class research into the neural basis of sensor and motor function in the brain. The opportunity was rare and exciting, but we truly started from scratch. My first glimpse of the lab was of completely empty room. The Boss told me what he wanted and said, “Build it.” MY ROLE This was my most complex and comprehensive accomplishment to date. I was responsible for procurement, installation, configuration, software development, and hardware development for everything in the lab. I was given broad budgetary discretion for purchases. If something was required and it didn’t exist, I designed it in Solidworks then fabricated it with machine tools or rapid prototyping machines. If software was required, I developed it in C/C++, Python, Matlab, Simulink, etc... Over the next 2 years the following core pieces of the laboratory setup were developed: 1. 6-AXIS INDUSTRIAL ROBOT: A robot arm was required to present objects to research subjects. Developed custom real-time control routines in C++ using manufacturer SDK. Integrated pneumatic end effector tool changer system with 6-DoF Force/Torque sensor. Developed custom front end GUI using LabView. 2. VIRTUAL REALITY SIMULATION: Our experiments required subjects to execute tasks in a virtual reality environment. This was developed in the Python programming language in using Vizard development software. VR control was integrated into overall system using LabView. 3. 3-D MOTION CAPTURE: We tracked and analyzed the detailed kinematics of our subjects’ hand during the experimental task using an active marker (LED) system from Phasespace. Developed custom marker arrays and core software routines to acquire maker data in real time to drive animations in the VR simulation. 4. NEUROPHYSIOLOGICAL RECORDING SETUP: We recorded the activity of single neurons in the sensory cortex of the brain during our experiments. The Plexon system was integrated in the overall system using LabView software
  • 2. 5. SYSTEM CONTROL SOFTWARE: Developed a hybrid PC/Real-Time application in LabView to unify all components of the system, including sensory I/O, robot commands and VR control. The end product was a unified control GUI from which all aspects of the experiment could be monitored and controlled. 6. MONKEYS!!: Truly the most unpredictable and challenging aspect of the this work; an education within an education. Learned to handle, train and work with two male Rhesus macaque monkeys to obtain neurophysiological data. OUTCOME After nearly four and a half years of continuous work, I completed my experimental work and doctoral dissertation, graduating in May of 2010. My legacy is a neurophysiological recording laboratory that is uniquely capable, flexible and reconfigurable for many kinds of neural experimentation protocols. Accomplishing the PhD made me a better engineer and taught me how to carry out research. What I now seek is the opportunity to unify the myriad skills acquired in my work and education so far into a single goal requiring multidisciplinary skills.
  • 3. EXPERIMENTAL SETUP 1. Monkeys were trained in a novel Reach-to-Grasp task in which all visual cues were presented in a Virtual Reality simulation. 2. Grasp object of different sizes were presented in the workspace behind the VR presentation and hand position and digit kinematics were tracked using an active marker motion capture system. 3. The firing activity of single neurons in sensory cortex was recorded while the monkeys completed either a physical task (object present in the workspace) or a randomly inserted virtual task (object presented just out of reach) 4. This approach permitted manipulation of the actual and expected sensory outcome of the task.
  • 4. SMORG ROBOT AND ASSOCIATED HARDWARE. A b3 B b2 b1 C A. THE 6-AXIS INDUSTRIAL ROBOT. Mounted on a custom platform and controlled using custom software. Dedicated signal and air channels routed through the robot enabled feedback from a 6-DOF F/T sensor, object touch sensors and control of a pneumatic tool changer. B. THE ROBOT END EFFECTOR. The F/T sensor (b2) was mounted directly to the robot end effector (b1). The master plate of the tool changer (b3) was mounted to the F/T sensor using a custom interface plate. Air lines originating from ports on the robot controlled the locking mechanism of the master plate. C. GRASP OBJECT ASSEMBLY. The object was mounted to a six-inch standoff post that mounted to a tool plate. Touch sensors were mounted flush with the object surface and wires were routed to the object interior for protection. Power and signal lines were routed through a pass- through connector (not visible), through the robot interior to an external connector on the robot base.
  • 5. CAPTURING HAND KINEMATICS. A B C D Our experiments required knowledge of detailed hand kinematics – of monkeys! This figure highlights just some of the hardware and electronics development I conducted to accomplish this task. A. COMMERCIALLY AVAILABLE DATA GLOVES feature numerous integrated bend sensors to capture the posture of the digits and palm but were prohibitively expensive and difficult to customize to the monkey hand. B. EARLY PROTOTYPE OF THE CUSTOM MONKEY GLOVE. Bend sensors and electronics were removed from a gaming glove and reconfigured to the monkey hand. C. A WIRELESS VERSION OF THE MONKEY GLOVE. This more advanced version featured 5 bend sensors, 2-axis roll/pitch sensing, wireless bluetooth transmisstion and a rechargeable battery. Electronics were encased in epoxy for protection. D. AN ALTERNATIVE STRATEGY FOR PASSIVE MOTION CAPTURE. Cube markers with finger attachment clips were developed to utilize larger markers for a novel camera sensing technique. This approach captured only crude measures of hand posture ACTIVE MARKER LEDS. We eventually settled on an active marker LED system from Phasespace, show at right.
  • 6. GENERAL SMORG LAB PICTURES TESTING ROOM Motion capture cameras surround the subject seating area. A 3D monitor placed overhead reflects the VR environment into a mirror directly ahead. The robot presented grasp objects in the workspace HARDWARE AND ELECTRONICS These experiments required the integration of much hardware and electronics CUSTOM HARDWARE These experiments also required the development of custom hardware, such as the grasp objects seen here.
  • 7. PROJECT: Experimental Device Development PRODUCT: Actuated Ankle Foot Orthosis (AAFO) ROLE: Project Manager OVERVIEW Advensys, LLC is an early stage startup company developing adaptive neuromorphic systems for “advancing human mobility.” In 2004 the company was awarded a competitive Phase I contract by the US Army to develop a neuromorphically controlled lower leg orthosis capable of providing ambulatory support for soldiers with injuries sustained in combat. The company was tasked with developing a prototype electronic control system based on neural pattern networks, management of AAFO hardware development and experimental assessment of the integrated system. The duration of Phase I prototype development, integration and testing was just 6 months. MY ROLE I was hired by the President and co-founder of the company as the Program Manager. My duties included several significant subtasks of the overall project: 7. NUMERICAL MODELING OF NEURAL PATTERN GENERATOR NETWORK: a biologically inspired oscillating signal generator patterned after spinal locomotor circuitry of the lamprey. The activity of this network could be entrained by an external periodic signal and would form the basis of our real-time control system. 8. PROTOTYPE ELECTRONICS DEVELOPMENT: Following numerical simulation and characterization, the neural pattern generator was implemented in breadboard electronics using RC circuit models of neural membrane dynamics. 9. REAL-TIME CONTROL SYSTEM DEVELOPMENT: A real-time numerical controller was developed using Matlab, Simulink and Real-Time Workshop. The controller was driven by a hip angle sensor and drove the ankle “push-off” of the AAFO. OUTCOME Phase I was completed on time and under budget. The device was demonstrated to senior Army program officials in a live demonstration and feedback was overwhelmingly positive. Advensys was invited to apply for Phase II funding, and was subsequently awarded approximately $1.5 million over 2 years.
  • 8. NUMERICAL MODELING OF NEURAL PATTERN GENERATOR NETWORK THE UNIT PATTERN GENERATOR (UPG) CONCEPT: A bi-laterally symmetric network whose connectivity is based on the known architecture of the lamprey spinal cord. The three spinal neural classes that form the kernel of the uPG are: E- excitatory, L-inhibitory, and C- crossed inhibitory. The E, L, and C neurons represent the core of the network and the M neurons are the “output” units of the network. SIMULATION RESULTS OF NEURAL NETWORK ENTRAINMENT IN RESPONSE TO INJECTED CURRENT INPUT. Both sides of the network oscillate at default frequency before entrainment, and then assume the frequency of the injected current.
  • 9. PROTOTYPE ELECTRONICS DEVELOPMENT PROTOTYPE UNIT PATTERN GENERATOR (UPG) ELECTRONICS: Unit Pattern Generator network showing neurons implemented in analog hardware. ELECTRONICS TESTING: uPG network testing
  • 10. REAL-TIME CONTROL SYSTEM DEVELOPMENT ! CONTROL SYSTEM DEVELOPMENT: Simulation and controller development were in Matlab, Simulink and Real-Time Workshop (RTW). Compiled, executable RTW code was ported to the Hardware Computer via an ethernet link. The Hardware Computer executed the real-time control system code, including sampling analog sensor input (analog-to-digital) from external hardware and asserting all analog commands (digital-to-analog) to hardware through the PCI DAS1200 A/D, D/A card. Two Break-Out Boards (BOB) provided numbered conductor connection points for system I/O. Motor commands, were sent from the BOB to the Amplifier Board, which directly drove the motor.