SlideShare a Scribd company logo
SECOND EDITION
EFFECTIVE DECEMBER 1, 2003




Construction
Performance
Guidelines
for the Ontario Home Building Industry




www.newhome.on.ca
Table of Contents


INTRODUCTION

Purpose of this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Scope of the Construction Performance Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Scope of Warranty Responsibilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Statutory Warranty Coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Conditions Not Covered Under Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Incomplete, Missing or Damaged Items – Pre-Delivery Inspection (PDI) . . . . . . . . . . . . . . . . . . . . 13
How to Use this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15


PERFORMANCE GUIDELINES
    1. FOUNDATION/BASEMENT
       1.1  Efflorescence is present on concrete or masonry surfaces . . . . . . . . . . . . . . . . . . . 18
       1.2  Interior concrete surfaces are powdery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
       1.3  Concrete surface is flaking off or “scaling” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
       1.4  Concrete floor without builder-applied finished flooring in basement is uneven . . . . 21
       1.5  Concrete basement floor is cracked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
       1.6  Concrete floor slab-on-ground has settled in a finished area . . . . . . . . . . . . . . . . . . 23
       1.7  No reinforcing in basement concrete slab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
       1.8  Concrete block foundation wall is cracked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
       1.9  Parging (not brush coating) is falling off above grade . . . . . . . . . . . . . . . . . . . . . . . . 26
       1.10 Exposed cast-in-place concrete foundation wall has holes in the surface . . . . . . . . 27
       1.11 Cast-in-place concrete foundation wall is cracked . . . . . . . . . . . . . . . . . . . . . . . . . . 28
       1.12 Condensation in crawl space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
       1.13 Basement wall or floor is damp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
       1.14 Foundation wall leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
       1.15 Water leakage through basement floor slab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

    2. FLOOR FRAMING
       2.1 Wood beam or post is split . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
       2.2 Wood beam or post is cupped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
       2.3 Structural column in unfinished basement is out of plumb . . . . . . . . . . . . . . . . . . . . 35
       2.4 Floor framing damaged by weather during construction. . . . . . . . . . . . . . . . . . . . . . 36
       2.5 Loose subfloor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
       2.6 Floor squeaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
       2.7 Finished floor above grade is out of level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
       2.8 Springiness, bounce, visible sag when loaded, or shaking is
             observed in the floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40



                                                          Construction Performance Guidelines
                                                          Second Edition, effective December 1, 2003
                                                          For more information, call 1-800-668-0124 or visit www.newhome.on.ca                         1
Table of Contents



    3. WALL FRAMING
       3.1  Wall is out of plumb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
       3.2  Wall is bowed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
       3.3  Malfunction of windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
       3.4  Window glass and/or screen is damaged . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
       3.5  Glass is scratched . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
       3.6  Glass is cracked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
       3.7  Window unit leaks during rain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
       3.8  Condensation forming between insulating (factory sealed) unit . . . . . . . . . . . . . . . . 48
       3.9  Exterior door is warped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
       3.10 Exterior metal door is dented . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
       3.11 Shrinkage of inserted panels shows raw wood edges on exterior wood doors . . . . 51
       3.12 Cracks and splits in exterior wood doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
       3.13 Exterior door sticks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
       3.14 Exterior door will not close completely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
       3.15 Plastic moulding on exterior door is deformed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
       3.16 Exterior door swings open or closed by itself . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
       3.17 Exterior door is crooked in the frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
       3.18 Exterior door hardware or decorative metal trim has discoloured . . . . . . . . . . . . . . . 58
       3.19 Sliding door screen will not stay on track or sliding door does not roll smoothly . . . 59

    4. EXTERIOR FINISHING
       4.1  Wood or hardboard, or panel-type siding is bowed or wavy . . . . . . . . . . . . . . . . . . . 60
       4.2  Wood or hardboard or panel-type siding – joints not tight . . . . . . . . . . . . . . . . . . . . 61
       4.3  Wood or hardboard or panel-type siding – fasteners are excessively
             countersunk into finished surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
       4.4  Lap siding (wood, hardboard, vinyl, etc.) is not installed on a straight line . . . . . . . . 63
       4.5  Tongue and groove wood siding has buckled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
       4.6  Wood siding – fastener has stained siding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
       4.7  Cedar shakes or shingles have “bled” through paint or stain applied by builder . . . . 66
       4.8  Plywood or veneer siding has delaminated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
       4.9  Aluminum/vinyl siding is bowed or wavy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
       4.10 Aluminum or vinyl siding – colour is faded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
       4.11 Aluminum or vinyl siding, trim or accessory is loose . . . . . . . . . . . . . . . . . . . . . . . . 70
       4.12 Aluminum or vinyl siding trim and accessories –
             fasteners don’t match siding colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
       4.13 Above-grade masonry wall or veneer cladding (including mortar) is cracked . . . . . . 72
       4.14 Cut bricks are of different thickness in relation to one another . . . . . . . . . . . . . . . . . 73
       4.15 Horizontal masonry joint alignment is not uniform . . . . . . . . . . . . . . . . . . . . . . . . . . 74
       4.16 Mortar splatters and stains on exterior masonry . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75



     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
2    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Table of Contents


  4. EXTERIOR FINISHING (continued)
     4.17 Efflorescence (white powder) is present on masonry surface . . . . . . . . . . . . . . . . . 76
     4.18 Deteriorating masonry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
     4.19 Water leakage at doors or windows or at the top of the foundation . . . . . . . . . . . . . 78
     4.20 Clay bricks are chipped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
     4.21 Bricks are different colours . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
     4.22 Cracks in exterior stucco wall surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
     4.23 Exterior stucco is peeling or bubbling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
     4.24 Unsealed gaps between dissimilar cladding materials
           and penetrations through cladding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
     4.25 Exterior wood trim is split . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
     4.26 Exterior wood trim is bowed, twisted or cupped . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
     4.27 Paint on repaired areas doesn’t match . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
     4.28 Exterior paint, stain or clear finish blisters and peels . . . . . . . . . . . . . . . . . . . . . . . . 87
     4.29 Exterior paint or stain has faded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
     4.30 Mould or mildew is visible on exterior painted surfaces . . . . . . . . . . . . . . . . . . . . . . 89
     4.31 Leak in exterior wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

  5. ROOFS
     5.1  Roof ridge has sagged . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
     5.2  Roof trusses or rafters are bowed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
     5.3  Roof appears wavy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
     5.4  Leaks due to snow or rain driven into attic through louvers or vents . . . . . . . . . . . . 94
     5.5  Roof or flashing leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
     5.6  Inadequate attic ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
     5.7  Ice buildup on the roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
     5.8  Roof shingles have blown off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
     5.9  Tabs on asphalt shingles are not lined up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
     5.10 Asphalt shingles not sealed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
     5.11 Asphalt shingle edges are curled or cupped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
     5.12 Asphalt shingles either do not overhang the edge of the roof
            or hang over too far . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
     5.13 Shading pattern is visible on an asphalt shingle roof . . . . . . . . . . . . . . . . . . . . . . . 103
     5.14 Variation in colour after repairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
     5.15 Uneven roof sheathing causing visible irregularities in the roof surface . . . . . . . . . 105
     5.16 Roofing nails are exposed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
     5.17 Temporary safety straps left on roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
     5.18 Water is trapped under roofing membrane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
     5.19 Asphalt roll roofing is blistered but does not admit water . . . . . . . . . . . . . . . . . . . . 109
     5.20 Standing water on a flat roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110



                                                    Construction Performance Guidelines
                                                    Second Edition, effective December 1, 2003
                                                    For more information, call 1-800-668-0124 or visit www.newhome.on.ca                 3
Table of Contents



    5. ROOFS (continued)
       5.21 Eavestroughs or downspouts leak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
       5.22 Eavestroughs overflow during normal rain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
       5.23 Eavestroughs or downspouts not performing properly . . . . . . . . . . . . . . . . . . . . . . 113
       5.24 Eavestroughs don’t drain completely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
       5.25 Skylight leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

    6. PLUMBING
       6.1  Inadequate water supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
       6.2  The domestic water supply system does not deliver water . . . . . . . . . . . . . . . . . . . 117
       6.3  Pipes are leaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
       6.4  Faucet or fixture is leaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
       6.5  Plumbing pipes are frozen and/or burst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
       6.6  Bathtub or shower leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
       6.7  Condensation appears on water supply pipes and toilets . . . . . . . . . . . . . . . . . . . . 122
       6.8  Noisy water pipes or “water hammer” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
       6.9  Defective plumbing fixtures, appliances or trim fittings . . . . . . . . . . . . . . . . . . . . . . 124
       6.10 Cracking or chipping of porcelain, enamel or fibreglass surfaces . . . . . . . . . . . . . . 125
       6.11 Lightweight (fibreglass and acrylic) bathtub or shower base flexes and creaks . . . 126
       6.12 Manufactured solid-surface countertop (integrated basin) cracks at the drain . . . . 127
       6.13 Toilet takes more than one flush to empty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
       6.14 Sewers, drains or fixtures blocked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129

    7. ELECTRICAL
       7.1  Fuses blow or circuit breakers trip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
       7.2  Ground-fault circuit interrupter (GFCI) trips frequently . . . . . . . . . . . . . . . . . . . . . . 131
       7.3  Electrical outlets or switches don’t work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
       7.4  Electrical fixture doesn’t work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
       7.5  Receptacle/switch cover plate is not flush with the wall . . . . . . . . . . . . . . . . . . . . . 134
       7.6  Exhaust fan duct terminates in attic or crawl space . . . . . . . . . . . . . . . . . . . . . . . . 135
       7.7  Interior light fixture tarnished . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
       7.8  Ceiling fan vibrates and is noisy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
4    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Table of Contents


  8. INTERIOR CLIMATE CONTROL
     8.1  Draft felt at electrical outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
     8.2  Air infiltration through doors and windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
     8.3  Kitchen or bath fans allow cold air infiltration or drafts . . . . . . . . . . . . . . . . . . . . . . 140
     8.4  Condensation in attic space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
     8.5  Condensation and/or frost on windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
     8.6  Condensation on interior ductwork and air handling equipment . . . . . . . . . . . . . . . 143
     8.7  Insufficient insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
     8.8  Heating, ventilating and air conditioning (HVAC) systems not installed properly . . . 145
     8.9  Inadequate heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
     8.10 Inadequate cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
     8.11 Noisy ductwork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
     8.12 Ductwork makes noise when someone walks on the floor –
            commonly known as “oil canning” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
     8.13 Noise can be heard at register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
     8.14 Ductwork comes apart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
     8.15 Condensate line is blocked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
     8.16 Air conditioning coolant line leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
     8.17 There are gaps between heat diffusers, cold air return grilles
            and ventilation grilles and the adjacent surface. . . . . . . . . . . . . . . . . . . . . . . . . . . 154

  9. WALL AND CEILING FINISH
     9.1  Ceiling is uneven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
     9.2  Ceiling texture is unevenly applied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
     9.3  Gypsum wallboard corners are uneven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
     9.4  Cracks in interior wall and ceiling surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
     9.5  Ceiling/wall joint separation commonly referred to as “truss uplift” . . . . . . . . . . . . . 159
     9.6  Drywall surface blemishes including nail/screw pops, blisters in taped joints,
           trowel marks, excess joint compound and dents or gouges . . . . . . . . . . . . . . . . . 160
     9.7  Texture of painted gypsum wallboard varies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
     9.8  Finished surface is rough . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
     9.9  Paint finish is unacceptable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
     9.10 Clear interior finishes have deteriorated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
     9.11 Paint is splattered on surfaces not intended to be painted . . . . . . . . . . . . . . . . . . . 165
     9.12 Wallcovering is peeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
     9.13 Patterns in wallcovering are mismatched at the edges . . . . . . . . . . . . . . . . . . . . . . 167
     9.14 Water penetration behind ceramic tile and bathtub or shower enclosures . . . . . . . 168
     9.15 Mildew or fungus is visible on interior surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169




                                                   Construction Performance Guidelines
                                                   Second Edition, effective December 1, 2003
                                                   For more information, call 1-800-668-0124 or visit www.newhome.on.ca                 5
Table of Contents



    10. INTERIOR FINISHING
        10.1 Interior door is warped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
        10.2 Bi-fold and sliding doors come off tracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
        10.3 Pocket door rubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
        10.4 Door rubs on the doorjamb or does not latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
        10.5 Wood door panel has split . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
        10.6 Door drags on the floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
        10.7 Gap between the door and the doorjamb is not uniform . . . . . . . . . . . . . . . . . . . . . 176
        10.8 Interior door swings open or closed by itself . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
        10.9 Doors bind from improperly installed hinges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
        10.10 Hinges are painted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
        10.11 Gaps exist between stair parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
        10.12 Squeaking stair riser or tread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
        10.13 Gaps exist between railing parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
        10.14 Stair railings lack rigidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
        10.15 Joint quality of interior trim work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
        10.16 Nailheads and fasteners are not properly set or filled . . . . . . . . . . . . . . . . . . . . . . . 185
        10.17 Interior trim is split . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
        10.18 Hammer marks are visible on trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
        10.19 Resin bleeding through painted finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
        10.20 Wall area around cold room door is unfinished. . . . . . . . . . . . . . . . . . . . . . . . . . . . 189

    11. CABINETS AND COUNTERTOPS
        11.1 Gap between cabinets and ceilings or walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
        11.2 Cabinets do not line up with each other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
        11.3 Cabinet doors and drawer faces are warped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
        11.4 Cabinet door or drawer binds or rubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
        11.5 Cabinet doors will not stay closed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
        11.6 Laminated countertop is swelled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
        11.7 Laminated countertop is delaminated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
        11.8 Cracks in countertop surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
        11.9 Scratches/chips on countertops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198

    12. FLOORING
        12.1 Transition between different types of flooring is not flush . . . . . . . . . . . . . . . . . . . . 199
        12.2 Floor is uneven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
        12.3 Pattern of finished flooring is out of alignment with adjacent wall surfaces . . . . . . 201
        12.4 Carpet seam is visible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
        12.5 Carpet is loose or stretching has occurred . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
        12.6 Spots or fading on carpet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204



     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
6    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Table of Contents


  12. FLOORING (continued)
      12.7 Carpet not uniform in colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
      12.8 Carpet has dark stains around perimeter of rooms and at heating registers . . . . . 206
      12.9 Hollow areas in underpad below carpet surface . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
      12.10 Protrusions appear on the surface of resilient flooring without breaking through . . 208
      12.11 Resilient sheet flooring is loose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
      12.12 Resilient flooring joints not tight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
      12.13 Bubbles appear on vinyl flooring surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
      12.14 Patterns on sheet vinyl flooring are not aligned across seams . . . . . . . . . . . . . . . . 212
      12.15 Resilient (flexible) floor tile is loose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
      12.16 Patterns or corners of resilient floor tile are misaligned . . . . . . . . . . . . . . . . . . . . . 214
      12.17 Yellowing appears on surface of vinyl flooring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
      12.18 Dye lot variations in vinyl flooring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
      12.19 Variation in colour occurring during repair of vinyl flooring . . . . . . . . . . . . . . . . . . . 217
      12.20 Cracks developing between strips of hardwood or parquet flooring . . . . . . . . . . . . 218
      12.21 Strip hardwood flooring is cupped (high edges) . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
      12.22 The surface of one strip of hardwood or parquet flooring is higher than another . . . 220
      12.23 Floor finish on wood flooring is not uniform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
      12.24 Finish on wood flooring has blistered, bubbled, or peeled resulting
             in detachment of finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
      12.25 Crowning of strip hardwood flooring has occurred
             (centre of strip is higher than edges) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
      12.26 Wood flooring buckles and detaches from substrate . . . . . . . . . . . . . . . . . . . . . . . 224
      12.27 Knots and colour variation in strip wood flooring . . . . . . . . . . . . . . . . . . . . . . . . . . 225
      12.28 Splinters occur in strip wood flooring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
      12.29 “Sticker burn” appears on surface of strip flooring . . . . . . . . . . . . . . . . . . . . . . . . . 227
      12.30 Ceramic/porcelain tile, marble or stone flooring is broken or loose
             (including marble transitions) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
      12.31 Cracks appearing in grouting of ceramic tile joints or at junctions
             with other materials such as bathtubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
      12.32 Adjacent marble units or ceramic tile surfaces installed at different elevations . . . 230
      12.33 Grout is not a uniform colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231

  13. CHIMNEYS AND FIREPLACES
      13.1 Joint or crack in chimney cap allows water leak . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
      13.2 Roof flashing leaks at chimney . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
      13.3 Bricks breaking up on surface of chimney . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
      13.4 Chimney serving solid-fuel-burning (wood, pellet, etc.) appliance
            does not draw properly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
      13.5 Fireplace firebox paint colour changed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
      13.6 Firebrick is broken . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237


                                                    Construction Performance Guidelines
                                                    Second Edition, effective December 1, 2003
                                                    For more information, call 1-800-668-0124 or visit www.newhome.on.ca                 7
Table of Contents



    14. GARAGES AND EXTERIOR
        14.1 Garage floor has heaved or settled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
        14.2 Concrete garage floor is cracked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
        14.3 No reinforcing in garage slab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
        14.4 Garage doors do not operate properly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
        14.5 Garage doors (vehicular and man-doors) allow entrance of snow or water . . . . . . 242
        14.6 Water accumulates on garage floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
        14.7 Asphalt or concrete driveway has cracked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
        14.8 Driveway has settled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
        14.9 Sod/seeding not completed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
        14.10 The shrubs, tree(s), plants, or sod have died . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
        14.11 Tree stumps have been left on the property . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
        14.12 Water ponding in surface grading of the site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
        14.13 Settling, heaving or separating of landings or steps . . . . . . . . . . . . . . . . . . . . . . . . 250
        14.14 Exterior deck is springy or shaky . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
        14.15 Exterior deck railing is shaky . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
        14.16 Deck board spacing is not uniform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
        14.17 Exterior wood handrails have slivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
        14.18 Exterior deck is out of level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
        14.19 Floor decking boards are split, warped or cupped . . . . . . . . . . . . . . . . . . . . . . . . . 256
        14.20 Stain colour variations on wood deck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
        14.21 Nailheads stick up on deck surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
        14.22 Stains on exterior decking from nailheads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
        14.23 Twisting of open-end beams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260


APPENDICES
    A1   Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
    A2   Moisture and Wood Floors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
    A3   Moisture and Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
    A4   Measuring Variation from the Specified Plane Using a Plane of Reference . . . . . . . . . . . 262
    A5   How to conduct a water test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
    A6   Chipped Clay Bricks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
    A7   Industry Agencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
8    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Introduction



PURPOSE OF THIS DOCUMENT

The Construction Performance Guidelines for the Ontario Home Building Industry (“Construction
Performance Guidelines” or “Guidelines”) will be used by the Ontario New Home Warranty Program
(the “Warranty Program”) when determining whether or not a condition is covered by the statutory
warranty. The purpose of the Guidelines is not to set new standards but to provide advance
information as to how the Warranty Program will decide disputes between builders and homeowners
about defects in work or materials. These Guidelines have been prepared in consultation with
various trade and industry groups and the Warranty Program is grateful for their input. A list of the
organizations that were consulted is included in Appendix A.

The Guidelines provide objective and uniform criteria that set out the minimum performance
required in the construction of new homes in Ontario. They relate to work and materials deficiencies
and complement the Ontario Building Code, which addresses structural integrity and health and
safety matters. In any case where a guideline is not consistent with a provision of the Ontario
Building Code, the Ontario Building Code will prevail. The Guidelines are designed to be supplemented
by any applicable guidelines or standards produced by industry associations. They do not replace
manufacturer warranties.

The Guidelines are designed primarily for conventional low-rise, wood frame construction – the
predominant method of residential construction in Ontario. Therefore, they may not be applicable
in all respects for other types of construction or assemblies.

The Warranty Program will make its decisions based on the edition of the Guidelines that is in
effect at the time a conciliation, warranty review or claim inspection is conducted. The effective date
is indicated on both the cover of the Guidelines and on the bottom of each page. (The Guidelines
will be reviewed periodically and expanded or updated to reflect legislative changes and/or changes
in construction materials and technologies. To date there have been two editions of the Guidelines
published. The first edition was effective on April 2, 2003 and the second edition was effective
December 1, 2003.)




                                        Construction Performance Guidelines
                                        Second Edition, effective December 1, 2003
                                        For more information, call 1-800-668-0124 or visit www.newhome.on.ca   9
Introduction



 SCOPE OF THE CONSTRUCTION PERFORMANCE GUIDELINES

 The Construction Performance Guidelines should be interpreted with common sense. They deal
 only with the most frequent and typical items of concern to homeowners. The Guidelines describe
 the minimum acceptable performance or condition that homeowners should expect and builders
 must meet to satisfy the requirements of the warranties described in the Ontario New Home
 Warranties Plan Act (“the Act”).

 Construction is not an exact science and generally, the materials used have natural properties
 and faults that must be considered when applying the Construction Performance Guidelines.
 For example:
     • Colours of all materials will be as close to samples as possible, but may not be identical to
       samples due to variances among manufacturers or differences in the manufacturing process;
     • Wood grains and colours may not necessarily match in all cases;
     • Shrinkage of natural materials may result in squeaks and creaks.


 Some items refer to specific dimensions to determine what is acceptable. These dimensions
 are used to evaluate the identified conditions. If the variation is minor, the Warranty Program may
 consider whether the variation significantly affects the performance of the item in determining
 whether the particular guideline has been met.

 SCOPE OF WARRANTY RESPONSIBILITIES

 Typically there may be a number of parties involved in a residential construction warranty issue
 in Ontario. The general responsibilities of the main parties are outlined below:

 The Homeowner 1: Before signing an Agreement of Purchase and Sale or construction contract,
 the prospective homeowner should carefully review the document to ensure that it expressly
 includes all the features agreed upon or to be selected during construction. Before signing a
 contract, the homeowner should seek legal advice, particularly if any aspect of the contract is
 unclear. Homeowners also have certain pre- and post-possession responsibilities to fulfill in order
 to preserve and exercise their statutory warranty rights. These responsibilities are briefly outlined
 in the section titled “Incomplete, Missing or Damaged Items” in this Introduction, and are explained
 in more detail in the Homeowner Information Package2.



 1 The term owner is defined in the Ontario New Home Warranties Plan Act – see the definition in the “Terminology” section on pages 15-17.
   Throughout this document the term homeowner will be used to refer to owners.
 2 The information contained in the Homeowner Information Package applies only to new freehold homes and condominium units with a date of

   possession on or after October 1, 2003.




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
10    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Introduction



Builder/Vendor3: The builder is responsible for honouring the first- and second-year warranties
set out in the Act and Regulations. The builder may at times have to go back to the manufacturer
to obtain a solution for a possible defect, which may delay the repair. For homes with a date of
possession on or after October 1, 2003, builders must also follow the Warranty Service Rules,
which are explained in detail in Builder Bulletin #42.

The Ontario New Home Warranty Program: The Warranty Program is responsible for administering
the Ontario New Home Warranties Plan Act. As part of this responsibility, the Warranty Program
makes decisions when builders and homeowners disagree about an item covered under the
statutory warranties. The Warranty Program also guarantees builders’ statutory warranties, and
provides extended major structural defect coverage for years three through seven after a home’s
date of possession.

STATUTORY WARRANTY COVERAGE

Warranty coverage is set out in the Act and takes effect from the date a homeowner takes
possession of a new home from the builder (the “date of possession”). It remains in effect even
if the home is sold or otherwise transferred before the end of the warranty period. There are three
types of statutory warranty protection or coverages, including:

The One-Year Warranty – A builder warrants that, for one year from the date of possession,
the home:
    • is free from defects in work and materials;
    • is fit to live in, and;
    • meets Ontario Building Code requirements.


Builders should provide homeowners with all warranties provided by manufacturers, suppliers and
subcontractors that may extend beyond the first year. Homeowners must make claims on these
extended warranties directly to the manufacturer or distributor.

A builder is also required to provide a warranty against delayed closings (or delayed occupancy for
condominium units) that occur without prescribed notice, and the homeowner may make a claim
under this warranty within one year after the date of possession. For more information on delayed
closings, homeowners should refer to the Homeowner Information Package or visit the Warranty
Program Web site at www.newhome.on.ca

3   The terms builder and vendor are defined in the Ontario New Home Warranties Plan Act – see the definitions included in the “Terminology” section
    on pages 15-17. Throughout this document the term builder will be used to refer to builders and vendors.




                                                             Construction Performance Guidelines
                                                             Second Edition, effective December 1, 2003
                                                             For more information, call 1-800-668-0124 or visit www.newhome.on.ca                      11
Introduction



 The Two-Year Warranty – A builder warrants that, for two years from the date of possession,
 the home is free from:
     • Water penetration through the basement or foundation walls;
     • Defects in materials or work (including windows, doors and caulking) that result in water
       penetration into the building envelope;
     • Defects in materials and work in the electrical, plumbing and heating delivery and
       distribution systems;
     • Defects in materials and work which result in detachment, displacement or deterioration of
       exterior cladding (such as brickwork, aluminum or vinyl siding);
     • Violations of Ontario Building Code regulations under which the Building Permit was issued,
       affecting health and safety, including, but not limited to, fire safety, insulation, air and vapour
       barriers, ventilation, heating and structural adequacy;
     • Major structural defects. For a definition of “major structural defect”, see the section
       entitled “Terminology”.

 Seven-Year Major Structural Defect4 Coverage – In addition to the builder’s two-year warranty
 against major structural defects, the Warranty Program provides extended coverage for major
 structural defects in years three through seven.

 CONDITIONS NOT COVERED UNDER WARRANTY

 It is important for homeowners to note what is not covered by the statutory warranty. The Act sets
 out the following exclusions from warranty coverage:
      • Defects in materials, design and work supplied by the homeowner;
      • Secondary damage caused by defects under warranty, such as property damage and
        personal injury;
      • Normal wear and tear;
      • Normal shrinkage of materials caused by drying after construction;
      • Damage caused by dampness or condensation due to failure by the homeowner to maintain
        adequate ventilation or proper operation of moisture-producing devices such as humidifiers;
      • Damage caused by the homeowner or visitors;
      • Alterations, deletions or additions made by the homeowner;
      • Settling of land around the building or along utility lines, other than beneath the footings of
        the building;
      • Damage resulting from acts of God;
      • Contractual warranties which lie outside the Ontario New Home Warranties Plan Act;
 4   The term “major structural defect” is defined in Regulation 892, Section 1, made under the Ontario New Home Warranties Plan Act, – see the
     definitions included in the “Terminology” section on pages 15-17.




         Construction Performance Guidelines
         Second Edition, effective December 1, 2003
12       For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Introduction



    • Damage caused by insects or rodents, except where construction does not meet
      specifications of the Ontario Building Code;
    • Damage caused by municipal services or other utilities;
    • Surface defects in work and materials specified and accepted in writing by the
      homeowner at the date of possession.

Warranty is also not applicable to:
   • Temporary or seasonal homes not built on permanent foundations and not insulated
     sufficiently to enable year-round living (i.e., cottages);
   • Homes built on pre-existing footings or foundations;
   • Homes that have been lived in or rented prior to sale;
   • Homes built in converted buildings;
   • Homes purchased from a receiver or trustee may not have warranty coverage
     in certain circumstances.

If there is any conflict between this publication and the Act or Regulations, the latter prevail.
The Warranty Program assumes no liability for any error or omission in this publication.

INCOMPLETE, MISSING OR DAMAGED ITEMS – Pre-Delivery Inspection (PDI)

A pre-delivery inspection (PDI) is conducted by the builder and the prospective homeowner (or the
homeowner’s designate), on or before the date of possession. The PDI provides an important
opportunity for the prospective homeowner to observe and record any items in the home that are
incomplete, missing, damaged or non-operational. If the item is covered by a statutory warranty, the
builder must repair the damaged or non-operational item, or install the missing or incomplete item.

For homes with a date of possession before October 1, 2003, these items should be recorded
on the Certificate of Completion and Possession (CCP) or in an attachment to the CCP. For
homes with a date of possession on or after October 1, 2003, these items must be recorded
on a Pre-Delivery Inspection Form (PDI Form) that has been approved by the Warranty Program.

Listing an incomplete, missing, damaged or non-operational item on the CCP or the PDI Form will
provide a formal record of the existence of the condition before the homeowner took possession.
Without this record it may be impossible for the Warranty Program to determine whether the item is
covered under warranty if a dispute arises as it may not be clear who caused the damage or
malfunction in question or whether an item was missing before the date of possession.




                                         Construction Performance Guidelines
                                         Second Edition, effective December 1, 2003
                                         For more information, call 1-800-668-0124 or visit www.newhome.on.ca   13
Introduction



 After the PDI, any PDI items not rectified by the builder and any new defects that have emerged
 should be reported in writing to both the builder and the Warranty Program within the applicable
 warranty period. For homes with a date of possession on or after October 1, 2003, the homeowner
 must report these items on standard Warranty Service Request Forms and submit them within the
 time periods set out in the Warranty Services Rules.

 For more information on the PDI and the Warranty Service Rules, homeowners should refer to
 the Homeowner Information Package.

 HOW TO USE THIS DOCUMENT

 The Construction Performance Guidelines are divided into articles based on construction
 sequence. The information is organized according to types of conditions, and in each case,
 the following is described:
     • Condition: A brief description of the identified situation.
     • What is acceptable: The acceptable performance standard of the condition.
     • Which warranty applies: The statutory warranty that applies and any exclusions.
     • Required action: A description of the action that the builder or homeowner must take
       to rectify the identified condition.
     • Remarks: Information to help users understand and solve the problem.




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
14   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Introduction



TERMINOLOGY

Builder
The person or entity that undertakes the performance of all work and supply of all the materials
necessary to construct a completed home whether for the purpose of sale by the person or entity or
under a contract with a vendor or homeowner. In these Guidelines, the term “builder” is used to refer
to both vendors and builders.

Building Envelope
The wall and roof assemblies that contain the building space, and include all those elements of the
assembly that contribute to the separation of the outdoor and indoor environments so that the indoor
environment can be controlled within acceptable limits.

Contract
The Agreement of Purchase and Sale between the builder and homeowner, or the construction
contract between the builder and homeowner who owns the land.

Date of Possession
The date on which the home is completed by the builder for possession by the first homeowner.

Delivery and Distribution Systems
Include all wires, conduits, pipes, junctions, switches, receptacles and seals, but does not include
appliances (except furnaces), fittings and fixtures.

Exterior Cladding
All exterior wall coverings, including siding and above-grade masonry (for example, concrete, bricks,
or stone) as required and detailed in the relevant sections of the Ontario Building Code under which
the Building Permit was issued.

Home
Includes self-contained one-family dwellings, whether attached or detached; buildings consisting of
two or less self-contained one-family dwellings under common ownership; or a condominium dwelling
unit, including the common elements. Also includes any structure used in conjunction with the home,
but does not include a building built and sold for temporary occupancy or for seasonal purposes.




                                         Construction Performance Guidelines
                                         Second Edition, effective December 1, 2003
                                         For more information, call 1-800-668-0124 or visit www.newhome.on.ca   15
Introduction



 Homeowner
 The person who first acquires the home from a builder for occupancy, and the person’s successor
 in title.

 Major Structural Defect
 Any defect in work or materials:
         a) that results in failure of the load-bearing portion of any building, or materially and
           adversely affects its load-bearing function, or
         b) that materially and adversely affects the use of such building for the purpose for which it
           was intended,
 Including:
         • significant damage due to certain types of soil movement,
         • major cracks in basement walls,
         • collapse or serious distortion of joints or roof structure and chemical failure of materials.
 Excluding any defect attributable in whole or in part to:
         • flood damage,
         • dampness not arising from failure of a load-bearing portion of the building,
         • damage to drains or services,
         • damage to finishes, and
         • damage arising from acts of God, acts of the homeowners and their tenants, licensees
           and invitees, acts of civil and military authorities, acts of war, riot, insurrection or civil
           commotion and malicious damage.

 Normal
 Typical, usual, ordinary or reasonably expected.

 PDI
 Pre-Delivery Inspection of the home, which is conducted by the builder together with the purchaser
 or their designate.

 Properly painted surface
 Uniform in appearance, colour and sheen, free of foreign material, lumps, skins, runs, sags,
 insufficient coverage, drips, spatter, spills and over spray.




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
16   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Introduction



Repair
Activity to be undertaken by the builder as referred to under Action for conditions included in the
Construction Performance Guidelines. The method of repair may involve restoration, alteration, or
partial or full replacement of materials or equipment. The builder must choose a repair method that
will satisfy the acceptable performance/condition specified in the applicable guideline.

Generally, where repairs are necessary, colour and/or texture may not match exactly the surrounding
original material.

Smooth
An even surface that is free from bumps, projections, foreign material, etc.

Specified plane
A flat, invisible line between two points on the surface of a wall, ceiling or floor which defines the
intended flat surface. The points shall be located as far apart as possible, e.g. opposite sides of a
room or opposite ends of a wall. Such a plane of reference is used to measure the variation between
the specified plane and the actual surface. See Appendix A4 “Measuring Variation from the Specified
Plane Using a Plane of Reference”.

Vendor
The person or entity who sells on its own behalf a home not previously occupied to a homeowner.

Visible
Easily seen when viewed from a position that is normal to the use of the room or area – e.g., hallway –
standing position; living room – standing or sitting.




                                         Construction Performance Guidelines
                                         Second Edition, effective December 1, 2003
                                         For more information, call 1-800-668-0124 or visit www.newhome.on.ca   17
Foundation/Basement



1.1

CONDITION
EFFLORESCENCE IS PRESENT ON CONCRETE OR MASONRY SURFACES

Acceptable Performance/Condition
Efflorescence may occur on concrete and masonry surfaces.

Warranty
None.

Action
The builder is not required to take any action.

Remarks
Efflorescence is the formation of a white crystalline deposit on the surface of concrete and masonry
when moisture evaporates from the surface. It is an indication that moisture is moving through the
material to the surface, which is a normal condition. Efflorescence can be removed with a stiff brush
and water.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   18
Foundation/Basement



 1.2

 CONDITION
 INTERIOR CONCRETE SURFACES ARE POWDERY

 Acceptable Performance/Condition
 Concrete surfaces shall be sufficiently hard to prevent powdering which results in exposure
 of the aggregate.

 Warranty
 One-Year – Work and Materials
 • Surface deterioration due to owner-applied substances is excluded from the statutory warranty.

 Action
 Where powdering occurs exposing the aggregate the concrete surface shall be repaired to provide
 a hardened surface.

 Remarks
 Some dusting of the concrete surface may normally occur; however, where the aggregate becomes
 exposed the condition is considered excessive. The colour and texture of a repaired area may not
 match the surrounding concrete.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
19     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Foundation/Basement



1.3

CONDITION
CONCRETE SURFACE IS FLAKING OFF OR “SCALING”

Acceptable Performance/Condition
Concrete surfaces shall not disintegrate to the extent that the aggregate is exposed under normal
conditions of weathering and use.

Warranty
One-Year – Work and Materials
• Surface deterioration due to owner-applied substances, improper maintenance, or normal wear
  and tear is excluded from the statutory warranty.

Action
Where defective installation or product is determined the concrete surface shall be repaired.

Remarks
Scaling most often results from salts and de-icers being applied to the concrete surface, e.g. either
intentionally for ice melting or unintentionally from road slush deposits. Cleaning salt deposits off
concrete surfaces is normal home maintenance.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   20
Foundation/Basement



 1.4

 CONDITION
 CONCRETE FLOOR WITHOUT BUILDER-APPLIED FINISHED FLOORING
 IN BASEMENT IS UNEVEN

 Acceptable Performance/Condition
 Within a 3 m specified plane, concrete floors shall not have bumps or depressions exceeding ±12 mm.
 Sloped areas providing drainage to floor drains are not considered to be uneven.

 Warranty
 One-Year – Work and Materials

 Action
 Uneven floors exceeding the acceptable condition shall be repaired.

 Remarks
 Repairs may include grinding or applying a topping. The colour and texture of a repaired area may
 not match the surrounding concrete.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
21     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Foundation/Basement



1.5

CONDITION
CONCRETE BASEMENT FLOOR IS CRACKED

Acceptable Performance/Condition
Cracks resulting from normal shrinkage are acceptable; cracks in excess of 6 mm in width are
not acceptable.

Warranty
One-Year – Work and Materials
• Cracks resulting from normal shrinkage of materials caused by drying after construction are
  excluded from the statutory warranty.

Action
Cracks in excess of the acceptable condition shall be repaired.

Remarks
Concrete floors naturally crack during curing due to shrinkage. Actual crack widths shall be
determined using a wire feeler gauge* inserted inside the crack. Where repairs are necessary,
colour and/or texture may not match the surrounding concrete.

* Because it is of a manufactured, set size, an Allen Wrench/Key may be used as a wire feeler gauge.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   22
Foundation/Basement



 1.6

 CONDITION
 CONCRETE FLOOR SLAB-ON-GROUND HAS SETTLED IN A FINISHED AREA

 Acceptable Performance/Condition
 At the perimeter of rooms, concrete floor slabs shall not settle more than 12 mm from their
 original position.

 Warranty
 One-Year – Work and Materials

 Action
 Slabs that settle more than the acceptable condition shall be repaired.

 Remarks
 None.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
23     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Foundation/Basement



1.7

CONDITION
NO REINFORCING IN BASEMENT CONCRETE SLAB

Acceptable Performance/Condition
Unless the slab is specifically intended and designed to be a structural slab, reinforcing or mesh
is not required.

Warranty
One-Year – Work and Materials
Seven-Year – Major Structural Defect

Action
Where a structural slab is not reinforced as required by the design, repairs shall be made;
otherwise no action is required.

Remarks
Concrete slabs in basements shall conform to Section 9.16 of the Ontario Building Code.
Reinforcing of concrete slabs is not usually necessary unless unusual design or construction
conditions are encountered.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   24
Foundation/Basement



 1.8

 CONDITION
 CONCRETE BLOCK FOUNDATION WALL IS CRACKED

 Acceptable Performance/Condition
 Cracks resulting from normal shrinkage are acceptable; cracks in excess of 6 mm in width are
 not acceptable.

 Warranty
 One-Year – Work and Materials
 • Cracks resulting from normal shrinkage of materials caused by drying after construction are
   excluded from the statutory warranty.

 Action
 Cracks in excess of the acceptable condition shall be repaired.

 Remarks
 Where crack width exceeds the acceptable condition, or where lateral or vertical movement
 is evident, further investigation may be required.
 The colour and texture of a repaired area may not match the surrounding concrete.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
25     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Foundation/Basement



1.9

CONDITION
PARGING (NOT BRUSH COATING) IS FALLING OFF ABOVE GRADE

Acceptable Performance/Condition
Hairline cracks are normal in parged surfaces; parging that is separating from the concrete
block base is not acceptable.

Warranty
One-Year – Work and Materials
• Cracks resulting from normal shrinkage of materials due to normal drying after construction
  are not covered by the statutory warranty.

Action
Parging not meeting the acceptable condition shall be repaired.

Remarks
The Ontario Building Code only requires parging (a cement-based layer) on concrete block
foundation walls below grade.
Brush coating, however, is only a cosmetic application over poured concrete foundation walls
and is not covered by the statutory warranty.
Slight variation in the colour or texture of repaired areas is acceptable.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   26
Foundation/Basement



 1.10

 CONDITION
 EXPOSED CAST-IN-PLACE CONCRETE FOUNDATION WALL HAS HOLES IN THE SURFACE

 Acceptable Performance/Condition
 The exterior portion of foundation walls exposed to view above grade shall have no holes (including
 “honeycombing”) larger than 50 mm in diameter or 25 mm deep.

 Warranty
 One-Year – Work and Materials

 Action
 Walls with holes exceeding the acceptable condition shall be repaired.

 Remarks
 It is impossible to completely eliminate all surface voids. At the builder’s discretion a brush coat may
 be applied. The colour and texture of a repaired area may not match the surrounding concrete.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
27   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Foundation/Basement



1.11

CONDITION
CAST-IN-PLACE CONCRETE FOUNDATION WALL IS CRACKED

Acceptable Performance/Condition
Cracks resulting from normal shrinkage are acceptable; cracks in excess of 6 mm in width are
not acceptable.

Warranty
One-Year – Work and Materials
• Cracks resulting from normal shrinkage of materials caused by drying after construction
  are excluded from the statutory warranty.

Action
Walls with cracks exceeding the acceptable condition shall be repaired.

Remarks
Concrete walls naturally crack during curing due to shrinkage. Where lateral or vertical movement
is evident, further investigation may be required.
The colour and texture of a repaired area may not match the surrounding concrete.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   28
Foundation/Basement



 1.12

 CONDITION
 CONDENSATION IN CRAWL SPACE

 Acceptable Performance/Condition
 Condensation shall not accumulate on crawl space interior surfaces.

 Warranty
 Two-Year – Ontario Building Code Health & Safety Violations
 • Damage caused by dampness or condensation due to failure by the homeowner to maintain
   adequate ventilation is excluded from the statutory warranty.

 Action
 Adequate ventilation equipment shall be installed in accordance with the Ontario Building Code.

 Remarks
 Crawl spaces shall be ventilated in accordance with the Ontario Building Code. Crawl space
 ventilation requires careful management by the homeowner to maintain acceptable moisture levels.
 Typical temporary conditions that may contribute to condensation are:
 a) at night in unheated crawl spaces, air entering the crawl space gradually cools the interior
    surfaces of the space. When outdoor temperatures rise the next day moisture picked up by
    the warm air is carried into the crawl space and condenses on the cool surfaces.
 b) at night in heated crawl spaces, outside air may rapidly cool foundation walls and provide
    a cool surface on which moisture in the crawl space can condense.
 c) if the house is left unheated in the winter, the floors and walls may provide cold surfaces
    on which moisture in the warmer crawl space may condense.
 d) stored materials obstruct ventilation airflow.
 These conditions may not be covered under the statutory warranty.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
29   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Foundation/Basement



1.13

CONDITION
BASEMENT WALL OR FLOOR IS DAMP

Acceptable Performance/Condition
Dampness on wall or floor surfaces caused by capillary transport or condensation of water vapour
may occur.
Only actual water penetration through an opening in the wall or floor may be covered by the
statutory warranty. See sections 1.14 “Foundation Wall Leaks” and 1.15 “Water Leakage Through
Basement Floor Slab”.

Warranty
None.
• Damage caused by dampness or condensation due to failure by the homeowner to maintain
  adequate ventilation is excluded from the statutory warranty.

Action
No action by the builder is required.

Remarks
Condensation can occur during peak seasonal weather patterns. The homeowner should
immediately reduce the moisture levels to prevent harm to property. Dampness can be reduced
by using a dehumidifier or by increasing the amount of ventilation to the area.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   30
Foundation/Basement



 1.14

 CONDITION
 FOUNDATION WALL LEAKS

 Acceptable Performance/Condition
 Foundation walls shall allow no water penetration.

 Warranty
 Two-Year – Basement Water Penetration
 • Water leakage resulting from improper maintenance, exterior grade alterations made by the
   homeowner, an act of God or failure of municipal services or other utilities is excluded from the
   statutory warranty. Secondary damage to property or any personal injury resulting from the
   water penetration is also excluded from the statutory warranty.

 Action
 Water penetration through the basement or foundation shall be repaired.

 Remarks
 Only actual water penetration through the foundation is warranted; dampness caused by condensation
 or other causes is not considered to be water penetration and is not covered by the statutory
 warranty. The homeowner must take immediate steps to prevent damage to their property and
 report any losses to their home insurance provider.
 See Appendix A5 “How to Conduct a Water Test” for more information.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
31   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Foundation/Basement



1.15

CONDITION
WATER LEAKAGE THROUGH BASEMENT FLOOR SLAB

Acceptable Performance/Condition
Basement floor slabs shall allow no water penetration.

Warranty
Two-Year – Basement Water Penetration
• Water leakage resulting from improper maintenance, exterior grade alterations made by the
  homeowner, an act of God or failure of municipal services or other utilities is excluded from the
  statutory warranty. Secondary damage to property or any personal injury resulting from the
  water penetration is also excluded from the statutory warranty.

Action
Defects resulting in water penetration through the basement floor slab shall be repaired.
Subsurface investigation may be required.

Remarks
Only actual water leakage through the floor slab is warranted; dampness or condensation is not
considered a warranted condition. The homeowner must take immediate steps to prevent damage
to their property and report any losses to their home insurance provider.
A thorough site investigation prior to construction and during excavation will assist in determining
whether groundwater levels may adversely affect the use of the building.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   32
Floor Framing



 2.1

 CONDITION
 WOOD BEAM OR POST IS SPLIT

 Acceptable Performance/Condition
 Load-bearing wood beams and posts that have splits and checks due to normal drying are acceptable
 if the beams and posts have been sized according to the Ontario Building Code and no structural
 deficiency exists. Where the wood beam or post is also intended to be decorative, splits and checks
 resulting from normal shrinkage are acceptable.

 Warranty
 One-Year – Work and Materials
 Seven-Year – Major Structural Defect
 • Splits and checks resulting from normal shrinkage caused by drying after construction are
   excluded from the statutory warranty.

 Action
 Splits and checks not meeting the acceptable performance shall be repaired.

 Remarks
 Wood beams and posts are timbers that are solid-sawn and at least 114 mm (41/2") in their smallest
 dimension. Some characteristics of drying wood, such as splitting and checking, are beyond the
 control of the builder and cannot be prevented. Splitting and checking are primarily aesthetic
 concerns rather than structural problems.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
33     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Floor Framing



2.2

CONDITION
WOOD BEAM OR POST IS CUPPED

Acceptable Performance/Condition
Load-bearing wood beams and posts that are cupped due to normal drying are acceptable
if the beams and posts have been sized according to the Ontario Building Code and no
structural deficiency exists.

Warranty
One-Year – Work and Materials
Seven-Year – Major Structural Defect
• Cups resulting from normal shrinkage caused by drying after construction are excluded from
  the statutory warranty.

Action
Cupped beams and posts not meeting the acceptable condition shall be repaired.

Remarks
Wood beams and posts are timbers that are at least 114 mm (41/2") in their smallest dimension.
A characteristic of drying wood such as cupping is beyond the control of the builder and cannot
be prevented. Cupping is primarily an aesthetic concern rather than a structural problem.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   34
Floor Framing



 2.3

 CONDITION
 STRUCTURAL COLUMN IN UNFINISHED BASEMENT IS OUT OF PLUMB

 Acceptable Performance/Condition
 Structural columns (wood, masonry, concrete or steel) in an unfinished basement shall not
 be out of plumb more than 25 mm in 2,400 mm.

 Warranty
 One-Year – Work and Materials
 Seven-Year – Major Structural Defect

 Action
 Structural columns out of plumb more than the acceptable condition shall be repaired.

 Remarks
 None.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
35     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Floor Framing



2.4

CONDITION
FLOOR FRAMING DAMAGED BY WEATHER DURING CONSTRUCTION

Acceptable Performance/Condition
The joists and subfloor shall be sound and free from damage caused by weathering and must
provide a suitable base for finished flooring.

Warranty
One-Year – Work and Materials
Seven-Year – Major Structural Defect

Action
Joists and subfloors damaged by weathering to the extent that they cannot carry the anticipated
loads or are made unsuitable for finished flooring shall be repaired.

Remarks
Materials that can be significantly damaged by weather should be protected during storage and
construction. Composite panels such as oriented strandboard and plywood used for subfloors
and webs of manufactured joists require more protection than solid-sawn lumber and can swell
or delaminate if saturated over lengthy periods. Discolouration alone does not necessarily indicate
a warrantable condition.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   36
Floor Framing



 2.5

 CONDITION
 LOOSE SUBFLOOR

 Acceptable Performance/Condition
 Subfloors shall not become loose and no movement shall be felt underfoot under normal
 loading conditions. Subfloors shall be fastened in accordance with the Ontario Building Code.

 Warranty
 One-Year – Work and Materials
 Two-Year – Ontario Building Code Health & Safety Violations
 • Normal shrinkage of materials caused by drying after construction is excluded from the
   statutory warranty.

 Action
 Where movement of the subfloor is confirmed, repairs shall be made.

 Remarks
 Delamination of plywood subfloors is considered a warranted defect in material.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
37     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Floor Framing



2.6

CONDITION
FLOOR SQUEAKS

Acceptable Performance/Condition
Floors shall be free from squeaks caused by movement in the floor system connections
under normal loading conditions.

Warranty
One-Year – Work and Materials
• Squeaks resulting from normal shrinkage of materials caused by drying after construction
  are excluded from the statutory warranty.

Action
Loose connections causing floor squeaks shall be repaired.

Remarks
Extended low-humidity indoor environments can cause excessive shrinkage in the wood
resulting in loose floor connections. The homeowner must maintain indoor humidity levels
to prevent excessive drying of materials. A squeak-free floor may not be attainable.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   38
Floor Framing



 2.7

 CONDITION
 FINISHED FLOOR ABOVE GRADE IS OUT OF LEVEL

 Acceptable Performance/Condition
 Within a room, floors shall appear level when viewed from a normal viewing position. Where a floor
 framed with dimensional lumber appears sloped, a maximum tolerance ratio of 25 mm in 3600 mm
 applies, when measured between the opposite walls or defined limits of the room or area.

 Warranty
 One-Year – Work and Materials
 • Minor slope variance caused by normal shrinkage of materials due to drying after construction
   is excluded from the statutory warranty.

 Action
 Floors in rooms sloped greater than the acceptable performance shall be repaired.

 Remarks
 This item refers to the entire floor surface in rooms. Where a floor is framed with an engineered
 floor system, minor slope variations caused by the required camber in the long-spanned joists
 supporting the floor are excluded from the statutory warranty.
 For uneven areas in floors see section 12.2 “Floor is Uneven”.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
39     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Floor Framing



2.8

CONDITION
SPRINGINESS, BOUNCE, VISIBLE SAG WHEN LOADED, OR SHAKING
IS OBSERVED IN THE FLOOR

Acceptable Performance/Condition
These conditions are acceptable when all structural members including beams and joists are
sized, installed and fastened in accordance with the Ontario Building Code.

Warranty
One-Year – Work and Materials
Two-Year – Ontario Building Code Health & Safety Violations

Action
Floors not meeting the performance condition shall be repaired.

Remarks
Long-spanned floor joists will normally move more than short-spanned joists under design loads.
The conditions can be assessed by determining the performance under loading conditions;
measuring the length of the structural member and dividing by 360 will give the maximum
deflection allowed.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   40
Wall Framing



 3.1

 CONDITION
 WALL IS OUT OF PLUMB

 Acceptable Performance/Condition
 Where the condition is visible from a normal viewing position, walls shall not be out of plumb
 more than 25 mm in 2,400 mm vertical measurement.

 Warranty
 One-Year – Work and Materials

 Action
 Walls not meeting the acceptable condition shall be repaired.

 Remarks
 It is reasonable to expect minor variation from plumb. Fitment of furnishings is not considered
 to be the test for plumb.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
41     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall Framing



3.2

CONDITION
WALL IS BOWED

Acceptable Performance/Condition
On the interior of a home, where bowed framing causes local distortion, the variation shall not
be more than ±20 mm from the specified plane.

Warranty
One-Year – Work and Materials
• Distortion due to shrinkage caused by normal drying after construction is not covered by the
  statutory warranty.

Action
Bows exceeding the acceptable condition shall be repaired.

Remarks
It is reasonable to expect walls to have variances in their finished surface. Varying light conditions
can exaggerate minor variations in appearance.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   42
Wall Framing



 3.3

 CONDITION
 MALFUNCTION OF WINDOWS

 Acceptable Performance/Condition
 Windows shall be installed to operate with reasonable ease.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance, or alterations, deletions or additions made
   by the homeowner is not covered by the statutory warranty.

 Action
 Windows not meeting the acceptable performance shall be repaired.

 Remarks
 Confirm proper operation of windows during the PDI and record any malfunction on the PDI Form
 to avoid any dispute about whether the damage was caused by the builder. Window operation
 varies with different window designs. Windows require regular maintenance for optimum
 performance.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
43     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall Framing



3.4

CONDITION
WINDOW GLASS AND/OR SCREEN IS DAMAGED

Acceptable Performance/Condition
Window glass and screens shall be free from damage at the time of the PDI.

Warranty
One-Year – Work and Materials

Action
Damaged window glass and screens reported on the PDI Form shall be repaired. If not noted, the
homeowner must establish that the damage was caused by the builder.

Remarks
Note any damaged windows or damaged/missing screens on the PDI Form. If not noted, it will be
difficult to establish that the damage was caused by the builder. If you cannot assess damage
because the surface of the windows has been obscured from view, this should also be noted
on the PDI Form.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   44
Wall Framing



 3.5

 CONDITION
 GLASS IS SCRATCHED

 Acceptable Performance/Condition
 Glass surfaces shall not have scratches visible from a distance of 1,500 mm at the time of the PDI.

 Warranty
 One-Year – Work and Materials
 • Damage due to improper maintenance and normal wear and tear is not covered by the
   statutory warranty.

 Action
 Scratched glass not meeting the acceptable condition and reported on the PDI Form shall be
 repaired. If not noted, the homeowner must establish that the damage was caused by the builder.

 Remarks
 Note any damage on windows on the PDI Form. If not noted, it will be difficult to establish that the
 damage was caused by the builder. If you cannot assess damage because the surface of the
 windows has been obscured from view, this should also be noted on the PDI Form.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
45     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall Framing



3.6

CONDITION
GLASS IS CRACKED

Acceptable Performance/Condition
Windows shall be installed so that the glass does not crack due to unusual stress caused
by movement or settlement of the building frame.

Warranty
One-Year – Work and Materials
• Damage resulting from normal wear and tear is not covered by the statutory warranty.

Action
Windows with glass showing stress cracks shall be repaired.

Remarks
Stress cracks occur across corners of glass as a result of pressure being applied to the
edge of the glass. If there is evidence of an impact, and the condition was not recorded on
the PDI Form, it will be difficult to establish that the damage was caused by the builder.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   46
Wall Framing



 3.7

 CONDITION
 WINDOW UNIT LEAKS DURING RAIN

 Acceptable Performance/Condition
 Windows shall not allow water penetration under normal weather conditions when properly closed.

 Warranty
 One-Year – Work and Materials
 Two-Year – Building Envelope Water Penetration
 • Damage caused by improper maintenance or an act of God is excluded from the
   statutory warranty.

 Action
 Defective windows that leak shall be repaired or replaced.

 Remarks
 The homeowner must ensure operable windows are properly closed, weatherstripping and
 caulking is maintained and drain ports are not obstructed.
 The window manufacturer may provide extended warranty coverage.
 See Appendix A5 “How to Conduct a Water Test” for more information.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
47     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall Framing



3.8

CONDITION
CONDENSATION FORMING BETWEEN INSULATING (FACTORY SEALED) GLASS UNIT

Acceptable Performance/Condition
Insulating glass units shall be free from condensation between the panes.

Warranty
One-Year – Work and Materials

Action
Insulating glass units with condensation between the panes shall be replaced.

Remarks
Condensation between panes indicates the airtight seal around the edge of the glass is broken.
An extended warranty may be available through the window manufacturer.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   48
Wall Framing



 3.9

 CONDITION
 EXTERIOR DOOR IS WARPED

 Acceptable Performance/Condition
 Doors shall not warp to the extent that they become inoperable or cease to be weather resistant.
 Doors between a home and an attached garage must be maintained to be gas-proof.

 Warranty
 One-Year – Work and Materials
 Two-Year – Ontario Building Code Health & Safety Violation for doors requiring gas-proofing.
 • Damage resulting from improper maintenance or alterations, deletions or additions made by
   the homeowner is not covered by the statutory warranty.

 Action
 Doors not meeting the acceptable performance shall be replaced.

 Remarks
 Confirm proper operation of exterior doors during the PDI and record any malfunction on the
 PDI Form to avoid any dispute about whether the damage was caused by the builder. Exterior
 doors can warp to some degree due to temperature differential between inside and outside
 surfaces. Garage doors between the garage space and the outdoors are not required to be
 weatherstripped.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
49     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall Framing



3.10

CONDITION
EXTERIOR METAL DOOR IS DENTED

Acceptable Performance/Condition
Exterior doors shall not be dented at the time of the PDI.

Warranty
One-Year – Work and Materials

Action
Dented exterior metal doors noted on the PDI Form shall be repaired. If not noted, the homeowner
must establish that the damage was caused by the builder.

Remarks
Identify damaged doors on the PDI Form to avoid any dispute about whether the damage was
caused by the builder. Filling the dent is an acceptable repair (e.g. spot putty).

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   50
Wall Framing



 3.11

 CONDITION
 SHRINKAGE OF INSERTED PANELS SHOWS RAW WOOD EDGES
 ON EXTERIOR WOOD DOORS

 Acceptable Performance/Condition
 Wooden panels will shrink and expand because of temperature and/or humidity changes, and
 may expose unpainted surfaces; this is acceptable. However, gaps between the edge of an
 inserted panel and the rest of the door caused by shrinkage are not normal and not acceptable.

 Warranty
 One-Year – Work and Materials
 • Normal shrinkage of materials caused by drying after construction is not covered by the
   statutory warranty.

 Action
 Doors not meeting the acceptable condition shall be repaired.

 Remarks
 None.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
51   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall Framing



3.12

CONDITION
CRACKS AND SPLITS IN EXTERIOR WOOD DOORS

Acceptable Performance/Condition
Cracks penetrating through the door are not acceptable.

Warranty
One-Year – Work and Materials

Action
Doors not meeting the acceptable condition shall be repaired.

Remarks
None.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   52
Wall Framing



 3.13

 CONDITION
 EXTERIOR DOOR STICKS

 Acceptable Performance/Condition
 Exterior doors and their hardware shall be installed to operate with minimal binding taking into
 account the weatherstripping seal and seasonal periods of high humidity.

 Warranty
 One-Year – Work and Materials
 • Alterations, deletions and additions made by the homeowner are not covered by the
   statutory warranty.

 Action
 Doors and hardware not meeting the acceptable performance shall be repaired.

 Remarks
 Confirm proper operation of exterior doors during the PDI and record any malfunction on the
 PDI Form to avoid any dispute about whether the damage was caused by the builder. Exterior
 doors can warp to some degree because of the difference in the temperature between inside
 and outside surfaces.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
53   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall Framing



3.14

CONDITION
EXTERIOR DOOR WILL NOT CLOSE COMPLETELY

Acceptable Performance/Condition
Exterior doors shall close completely and latch securely.

Warranty
One-Year – Work and Materials

Action
Doors not meeting the acceptable performance shall be repaired.

Remarks
Confirm proper operation of exterior doors during the PDI and record any malfunction on the
PDI Form to avoid any dispute about whether the damage was caused by the builder. Slight
pressure may be required during latching to compress the weatherstripping. Exterior doors
can warp to some degree because of the difference in the temperature between inside and
outside surfaces.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   54
Wall Framing



 3.15

 CONDITION
 PLASTIC MOULDING ON EXTERIOR DOOR IS DEFORMED

 Acceptable Performance/Condition
 The plastic mouldings on exterior doors shall not deform when the door is installed in accordance
 with the manufacturer’s installation instructions.

 Warranty
 One-Year – Work and Materials
 • Damage caused by improper maintenance or material, design or work supplied by the homeowner
   is not covered by the statutory warranty.

 Action
 Exterior doors not meeting the acceptable condition shall be repaired.

 Remarks
 Generally, exterior door manufacturers indicate storm doors are not to be installed over metal
 exterior doors. Heat buildup between a storm door and the exterior door can increase significantly,
 damaging any heat-susceptible parts such as plastic mouldings around a window insert or
 decorative surface-applied mouldings. The homeowner is also cautioned to follow manufacturer's
 recommendations on maintenance and painting the mouldings a dark colour, with or without the
 use of a storm door; dark-coloured moulding is likely to deform and should be avoided.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
55   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall Framing



3.16

CONDITION
EXTERIOR DOOR SWINGS OPEN OR CLOSED BY ITSELF

Acceptable Performance/Condition
Exterior doors shall be installed sufficiently plumb and square so they do not swing by
themselves due to the force of gravity alone.

Warranty
One-Year – Work and Materials
• Alterations, deletions or additions by the homeowner are not covered by the statutory warranty.

Action
Exterior doors not meeting the acceptable performance shall be repaired.

Remarks
Confirm proper operation of exterior doors during the PDI and record any malfunction on the
PDI Form to avoid any dispute about whether the damage was caused by the builder. Doors
will swing open or closed by the force of gravity if the hinges are not aligned plumb.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   56
Wall Framing



 3.17

 CONDITION
 EXTERIOR DOOR IS CROOKED IN THE FRAME

 Acceptable Performance/Condition
 Exterior doors must have a proper weather seal when closed. The weatherstripping must
 contact the perimeter of the door.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from normal wear and tear or improper maintenance is not covered by
   the statutory warranty.

 Action
 Exterior doors not meeting the acceptable condition shall be repaired.

 Remarks
 Confirm proper operation of exterior doors during the PDI and record any malfunction on the
 PDI Form to avoid any dispute about whether the damage was caused by the builder. Variance
 in the width of the gap between the door and the frame is acceptable unless the proper operation
 of the door is affected.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
57   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall Framing



3.18

CONDITION
EXTERIOR DOOR HARDWARE OR DECORATIVE METAL TRIM HAS DISCOLOURED

Acceptable Performance/Condition
Finishes on door hardware and fixtures may discolour.

Warranty
None.

Action
No action by the builder is required.

Remarks
Some hardware may have a coating to inhibit discolouration. Maintaining protective coatings
or removing discolouration is part of effective home maintenance. Oxidation and environmental
pollutants can accelerate discolouration.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   58
Wall Framing



 3.19

 CONDITION
 SLIDING DOOR SCREEN WILL NOT STAY ON TRACK OR SLIDING DOOR
 DOES NOT ROLL SMOOTHLY

 Acceptable Performance/Condition
 Sliding doors and their screens shall move freely on their tracks and latch securely.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from normal wear and tear or improper maintenance is not covered by
   the statutory warranty.

 Action
 Sliding doors and their screens not meeting the acceptable condition shall be repaired.

 Remarks
 Normal home maintenance for sliding doors and screens may involve adjustment from time
 to time and the tracks and hardware may need to be cleaned and lubricated. Confirm proper
 operation of the door and screen during the PDI and record any malfunction on the PDI Form
 to avoid any dispute about whether the damage was caused by the builder.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
59   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.1

CONDITION
WOOD OR HARDBOARD OR PANEL-TYPE SIDING IS BOWED OR WAVY

Acceptable Performance/Condition
Siding shall be installed to accommodate thermal movement and anticipated shrinkage of the
structure to which it is attached. Siding shall be free from bows and waviness when installed in
accordance with the manufacturer’s specifications. Where local distortion is caused by bowed
framing, the deviation of the bow measured from the specified plane shall not exceed ±20 mm.

Warranty
Two-Year – Cladding Detachment, Displacement or Deterioration
• Defects in materials, work or design supplied by the homeowner or damage resulting from
  improper maintenance are excluded from the statutory warranty.

Action
Bowed or wavy siding exceeding the acceptable condition shall be repaired.

Remarks
Siding that is intended to have paint and/or sealer requires regular inspection and maintenance
to ensure continuity of the protective layer. Elevated moisture levels can cause wood or
hardboard siding to bow. Varying lighting conditions can exaggerate minor variations in siding
profile and texture. Minor waviness due to normal fluctuations in humidity is acceptable.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   60
Exterior Finishing



 4.2

 CONDITION
 WOOD OR HARDBOARD OR PANEL-TYPE SIDING – JOINTS NOT TIGHT

 Acceptable Performance/Condition
 Wood or hardboard or panel-type siding shall be installed in accordance with the manufacturer’s
 specifications and the Ontario Building Code with gaps at joints to allow for expansion. Joints shall
 be suitably protected to prevent water penetration.

 Warranty
 One-Year – Work and Materials
 Two-Year – Building Envelope Water Penetration
 • Normal shrinkage of materials caused by drying after construction is excluded from the
   statutory warranty.
 • Defects in materials, work or design supplied by the homeowner and damage resulting from
   improper maintenance are excluded from the statutory warranty.

 Action
 Wood or hardboard or panel-type siding joints that do not meet the acceptable condition shall
 be repaired.

 Remarks
 Siding that is intended to have paint and/or sealer requires regular inspection and maintenance
 to ensure continuity of the protective layer. Wood, hardboard or panel-type siding can be expected
 to expand and contract with fluctuations in outdoor temperature and humidity; gaps in joints may
 be required to prevent buckling. Caulking or attaching battens over the joints are ways to protect
 the joints from water penetration.
 Where rain screen principles are used in the cladding design, the sealing may be behind the
 surface of the cladding.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
61     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.3

CONDITION
WOOD OR HARDBOARD OR PANEL-TYPE SIDING – FASTENERS ARE EXCESSIVELY
COUNTERSUNK INTO FINISHED SURFACE

Acceptable Performance/Condition
Siding fasteners shall be installed in accordance with the manufacturer’s specifications,
where applicable, and shall not expose hardboard siding fibre.

Warranty
One-Year – Work and Materials

Action
Siding with nails not meeting the acceptable condition shall be repaired.

Remarks
Nails that have been excessively countersunk detract from the overall appearance of the
finished surface. This condition can lead to premature deterioration of the product by allowing
water to accumulate in the holes left by the nailheads.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   62
Exterior Finishing



 4.4

 CONDITION
 LAP SIDING (WOOD, HARDBOARD, VINYL, ETC.) IS NOT INSTALLED ON A STRAIGHT LINE

 Acceptable Performance/Condition
 Lap siding shall be installed with individual pieces in general, visible parallel alignment.

 Warranty
 One-Year – Work and Materials
 • Defects in materials, work or design supplied by the homeowner are excluded from the statutory
   warranty.

 Action
 Lap siding that does not meet the acceptable condition shall be repaired.

 Remarks
 With any type of siding or cladding such as lap siding that requires repetitive parallel alignment
 from one course to the next, the installer must make minor adjustments to keep the entire
 elevation in general alignment. Adjustments of this nature are normal. Wavy-edged siding is
 more tolerant of adjustments while maintaining an acceptable appearance.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
63     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.5

CONDITION
TONGUE-AND-GROOVE WOOD SIDING HAS BUCKLED

Acceptable Performance/Condition
Tongue-and-groove wood siding shall be installed to prevent buckling and in accordance
with manufacturer’s installation instructions, where applicable.

Warranty
Two-Year – Cladding Detachment, Displacement or Deterioration

Action
Siding that does not meet the acceptable condition shall be repaired.

Remarks
None.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   64
Exterior Finishing



 4.6

 CONDITION
 WOOD SIDING – FASTENER HAS STAINED SIDING

 Acceptable Performance/Condition
 Fasteners shall be corrosion resistant and compatible with the siding in accordance with the
 Ontario Building Code.

 Warranty
 One-Year – Work and Materials
 One-Year – Ontario Building Code Violations
 • Damage resulting from normal wear and tear or damage resulting from improper
   maintenance is excluded from the statutory warranty.

 Action
 Siding and fasteners not meeting the acceptable condition shall be repaired.

 Remarks
 Fasteners can be expected to weather, oxidize and discolour with exposure to the elements.
 Some localized staining of adjacent materials may occur.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
65     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.7

CONDITION
CEDAR SHAKES OR SHINGLES HAVE “BLED” THROUGH PAINT OR STAIN
APPLIED BY BUILDER

Acceptable Performance/Condition
Where full-covering or opaque stains are used over cedar shakes or shingles, bleed-through of
resins or extractives shall not be visible when viewed, without magnification, from a minimum
perpendicular distance of 6 m under normal lighting conditions and from a normal viewing position.

Warranty
One-Year – Work and Materials
• Damage resulting from normal wear and tear is excluded from the statutory warranty.

Action
Cedar shakes and shingles that do not meet the acceptable condition shall be repaired.

Remarks
Some bleed-through of knots or other naturally occurring features can be expected in cedar
shakes over time. The reoccurrence of these features through full-covering or opaque stains
may be dependent on the direction the roof faces and/or exposure to sunlight.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   66
Exterior Finishing



 4.8

 CONDITION
 PLYWOOD OR VENEER SIDING HAS DELAMINATED

 Acceptable Performance/Condition
 Plywood or veneer siding shall not delaminate when installed in accordance with the
 manufacturer’s installation instructions.

 Warranty
 Two-Year – Cladding Detachment, Displacement or Deterioration
 • Damage resulting from normal wear and tear is excluded from the statutory warranty.

 Action
 Plywood/veneer siding that does not meet the acceptable condition shall be repaired.

 Remarks
 Siding that is intended to have paint and/or sealer requires regular inspection and maintenance
 to ensure continuity of the protective layer.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
67     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.9

CONDITION
ALUMINUM/VINYL SIDING IS BOWED OR WAVY

Acceptable Performance/Condition
Siding shall be installed to accommodate thermal movement and anticipated shrinkage of the
structure to which it is attached. Siding shall be free from bows and waviness when installed in
accordance with the manufacturer’s specifications. Where local distortion is caused by bowed
framing the variation from the specified plane shall not exceed ±20 mm.

Warranty
One-Year – Work and Materials
Two-Year – Cladding Detachment, Displacement or Deterioration

Action
Bowed or wavy siding exceeding the acceptable condition shall be repaired.

Remarks
Varying lighting conditions can exaggerate minor variations in siding profile, texture and colour.
Minor waviness due to normal sheathing movements is acceptable.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   68
Exterior Finishing



 4.10

 CONDITION
 ALUMINUM OR VINYL SIDING – COLOUR IS FADED

 Acceptable Performance/Condition
 Aluminum or vinyl siding shall not fade or discolour in an uneven or random manner.

 Warranty
 Two-Year – Cladding Detachment, Displacement or Deterioration
 • Damage resulting from normal wear and tear is excluded from the statutory warranty.

 Action
 Aluminum or vinyl siding that does not meet the acceptable performance shall be repaired.

 Remarks
 Aluminum or vinyl siding may fade with time and exposure to sunlight. Areas of intense,
 direct sunlight exposure will tend to fade faster than other more shaded areas.
 Repaired areas shall match the existing material for colour and textures as closely as
 possible; variation between dye lots is acceptable.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
69   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.11

CONDITION
ALUMINUM OR VINYL SIDING, TRIM OR ACCESSORY IS LOOSE

Acceptable Performance/Condition
Aluminum or vinyl siding and associated trim and accessories shall not become
displaced or detached from the substrate and shall be installed in accordance with the
manufacturer’s specifications.

Warranty
Two-Year – Cladding Detachment, Displacement or Deterioration
• Damage resulting from an act of God is excluded from the statutory warranty.

Action
Aluminum or vinyl siding that does not meet the acceptable condition shall be repaired.

Remarks
Aluminum or vinyl siding is intentionally not installed tight to the substrate to allow for thermal
movement; however, it should not displace or detach under normal weather conditions.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   70
Exterior Finishing



 4.12

 CONDITION
 ALUMINUM OR VINYL SIDING TRIM AND ACCESSORIES – FASTENERS DON’T
 MATCH SIDING COLOUR

 Acceptable Performance/Condition
 Fasteners that are used to secure aluminum or vinyl siding or trim may not match the siding
 or trim colour due to manufacturing limitations.

 Warranty
 None.

 Action
 The builder is not required to take any action.

 Remarks
 Fasteners are generally made in fewer standard colours than siding products.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
71   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.13

CONDITION
ABOVE-GRADE MASONRY WALL OR VENEER CLADDING (INCLUDING MORTAR)
IS CRACKED

Acceptable Performance/Condition
Cracks resulting from normal shrinkage are acceptable; crack width in excess of the ratio
of 3 mm in 10 m is not acceptable.

Warranty
One-Year – Work and Materials
• Cracks resulting from normal shrinkage of materials caused by drying after construction
  or normal wear and tear is excluded from the statutory warranty.

Action
Cracks in excess of the acceptable condition shall be repaired.

Remarks
Shrinkage during curing of the masonry is natural. Also, regular outdoor temperature
fluctuations cause masonry cladding to expand and contract. The resulting thermal stress
can also cause cracking; this is considered normal wear and tear.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   72
Exterior Finishing



 4.14

 CONDITION
 CUT BRICKS ARE OF DIFFERENT THICKNESS IN RELATION TO ONE ANOTHER

 Acceptable Performance/Condition
 Cut bricks used in the same course shall appear uniform from a normal viewing position;
 the variance in thickness between two immediately adjacent bricks shall not exceed 8 mm.

 Warranty
 One-Year – Work and Materials

 Action
 Bricks not meeting the acceptable condition shall be repaired.

 Remarks
 Even with proper coursing bricks will need to be cut to fit site conditions. It is common that
 cut bricks may vary in thickness. Uncut bricks may also vary in thickness depending on the
 style selected (e.g. tumbled bricks).

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
73   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.15

CONDITION
HORIZONTAL MASONRY JOINT ALIGNMENT IS NOT UNIFORM

Acceptable Performance/Condition
Horizontal masonry joint work shall appear uniform when viewed from a distance of 6 m.
Where the horizontal (bed) joint appears out of alignment, the variance shall not be more
than ±12 mm from the specified plane.
This does not apply to randomly sized masonry products.

Warranty
One-Year – Work and Materials

Action
Masonry with joints not meeting the acceptable condition shall be repaired.

Remarks
Dimensional variations of the courses are affected by the variations in the brick selected
and the bond pattern.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   74
Exterior Finishing



 4.16

 CONDITION
 MORTAR SPLATTERS AND STAINS ON EXTERIOR MASONRY

 Acceptable Performance/Condition
 Exterior masonry shall not have mortar splatters and stains detracting from the appearance of the
 finished wall when viewed from a distance of 6 m under natural lighting conditions when dry.

 Warranty
 One-Year – Work and Materials

 Action
 Masonry not meeting the acceptable condition shall be repaired.

 Remarks
 Care must be used in cleaning masonry. Although pressure washing and chemical cleaners are
 the normal way of cleaning masonry, they must be used properly and in accordance with brick
 manufacturer’s specifications.
 Professional brick tinting methods are acceptable to adjust colour.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
75   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.17

CONDITION
EFFLORESCENCE (WHITE POWDER) IS PRESENT ON MASONRY SURFACE

Acceptable Performance/Condition
Efflorescence commonly occurs on masonry surfaces and is normal. Localized concentrations
of efflorescence visible from 6 m are not acceptable.

Warranty
One-Year – Work and Materials
• Efflorescence resulting from additions, deletions or alterations made by the homeowner or
  improper maintenance is not covered by the statutory warranty.

Action
Localized concentrations of efflorescence visible from 6 m shall be investigated. If it is determined
that a defect in work or material is the cause of the efflorescence, repairs shall be made.

Remarks
Efflorescence is the harmless deposit of mineral salts on the surface of masonry and occurs
naturally due to the movement of moisture; it may diminish over time. Visibility varies with seasonal
conditions. Dark-coloured bricks tend to exaggerate the appearance of efflorescence. Localized
areas of efflorescence may be linked to abnormal sources of moisture.
Salt and de-icers may also contribute to efflorescence.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   76
Exterior Finishing



 4.18

 CONDITION
 DETERIORATING MASONRY

 Acceptable Performance/Condition
 Masonry shall be manufactured and installed to prevent premature deterioration.

 Warranty
 Two-Year – Cladding Detachment, Displacement or Deterioration
 • Damage resulting from normal wear and tear, improper maintenance or additions, alterations
   and deletions made by the homeowner is not covered by the statutory warranty.

 Action
 Masonry that is deteriorated, detached, or displaced shall be repaired.

 Remarks
 Durability is dependent on the type of masonry and the conditions that the masonry is exposed
 to (e.g. salt, soil).
 The colour/texture of repaired areas shall match the existing as closely as possible when dry.
 Variation in colour may be noticeable when wet. Where colour variation of the repaired area is
 visible under normal lighting and dry conditions from 6 m, the colour shall be adjusted.
 Professional brick tinting methods are acceptable to adjust colour.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
77   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.19

CONDITION
WATER LEAKAGE AT DOORS AND WINDOWS OR AT THE TOP OF THE FOUNDATION

Acceptable Performance/Condition
Openings in exterior walls such as windows and doors, and junctions between cladding materials,
shall not allow water penetration.

Warranty
One-Year – Ontario Building Code Violations
Two-Year – Building Envelope Water Penetration
• Water penetration due to improper maintenance is excluded from the statutory warranty.

Action
Defects resulting in water penetration around windows, doors, and over the top of the foundation
shall be repaired.

Remarks
Flashings must be installed above exterior wall openings and at the top of the foundation
(masonry veneer) to direct water to the exterior. Perforations in flashing due to physical damage
or chemical incompatibility, deterioration, improper termination and lack of weep holes in masonry
veneer can allow water to drain to the interior.
See Appendix A5 “How to Conduct a Water Test” for more information.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   78
Exterior Finishing



 4.20

 CONDITION
 CLAY BRICKS ARE CHIPPED

 Acceptable Performance/Condition
 Clay brick veneer shall be installed in accordance with the Ontario Building Code. Installed clay
 bricks that are visible as part of the cladding shall not be chipped in excess of the limits described
 in Appendix A7 “Chipped Clay Bricks”.

 Warranty
 One-Year – Work and Materials
 One-Year – Ontario Building Code Violations
 • Damage resulting from normal wear and tear, improper maintenance or additions, alterations
   and deletions made by the homeowner is not covered by the statutory warranty.

 Action
 Brick veneer not meeting the acceptable condition shall be repaired.

 Remarks
 There are certain brick types that are designed to be tumbled or chipped in appearance.
 Professional brick tinting methods are acceptable to repair the appearance of chipped bricks.
 The colour/texture of repaired areas shall match the existing as closely as possible when dry.
 Variation in colour may be noticeable when wet.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
79   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.21

CONDITION
BRICKS ARE DIFFERENT COLOURS

Acceptable Performance/Condition
Brickwork may contain bricks from different dye lots, provided they are dispersed throughout
the wall to produce a generally uniform appearance when viewed from 6 m under normal
lighting conditions.

Warranty
One-Year – Work and Materials

Action
Where a generally uniform appearance is not achieved the wall shall be repaired.

Remarks
Uniform appearance includes colour and texture. Professional brick tinting methods are
acceptable to adjust colour.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   80
Exterior Finishing



 4.22

 CONDITION
 CRACKS IN EXTERIOR STUCCO WALL SURFACES

 Acceptable Performance/Condition
 Stucco that relies on face-sealing to shed water shall have no cracks or gaps that will
 allow water penetration.
 Stucco on a drained cladding system shall not have unintentional gaps or cracks visible
 from a distance of not less than 6 m.

 Warranty
 Two-Year – Cladding Detachment, Displacement or Deterioration
 • Damage resulting from improper maintenance is not covered by the statutory warranty.

 Action
 Stucco finish not meeting the acceptable condition shall be repaired.

 Remarks
 Stucco includes traditional Portland cement-based stucco as well as synthetic stucco whether
 forming part of an exterior insulation and finish system (EIFS) or not. Caulking and sealants
 require regular maintenance to ensure effectiveness. The colour or texture of repaired areas
 shall match the existing so as not to be visible from a distance of 6 m under normal
 lighting conditions.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
81   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.23

CONDITION
EXTERIOR STUCCO IS PEELING OR BUBBLING

Acceptable Performance/Condition
Stucco on exterior walls shall not separate from its base.

Warranty
Two-Year – Cladding Detachment, Displacement or Deterioration
• Damage resulting from improper maintenance is not covered by the statutory warranty.

Action
Stucco not meeting the acceptable condition shall be repaired.

Remarks
Stucco separating from its base may indicate a problem with trapped moisture. Caulking
and sealants require regular maintenance to ensure effectiveness. The colour or texture
of repaired areas shall match the existing so as not to be visible from a distance of 6 m
under normal lighting conditions.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   82
Exterior Finishing



 4.24

 CONDITION
 UNSEALED GAPS BETWEEN DISSIMILAR CLADDING MATERIALS AND PENETRATIONS
 THROUGH CLADDING

 Acceptable Performance/Condition
 Gaps allowing water penetration into the building envelope shall be sealed in accordance
 with the Ontario Building Code.

 Warranty
 One-Year – Work and Materials
 One-Year – Ontario Building Code Violations
 Two-Year – Building Envelope Water Penetration
 Two-Year – Cladding Detachment, Displacement or Deterioration
 • Damage resulting from improper maintenance is not covered by the statutory warranty.

 Action
 Cladding not meeting the acceptable condition shall be repaired.

 Remarks
 Space between different cladding materials, and between penetrations is required
 to allow for movement but must be weathertight.
 Where rain screen principles are used in the cladding design, the sealing may be behind
 the surface of the cladding.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
83   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.25

CONDITION
EXTERIOR WOOD TRIM IS SPLIT

Acceptable Performance/Condition
Exterior wood trim may split; cracks visible from 6 m under normal lighting conditions,
or cracks resulting in displacement or detachment, are not acceptable.

Warranty
One-Year – Work and Materials
Two-Year – Cladding Detachment, Displacement or Deterioration
• Cracks resulting from normal shrinkage of materials caused by drying after construction,
  or normal wear and tear are not covered by the statutory warranty.

Action
Trim not meeting the acceptable condition shall be repaired.

Remarks
Some manufactured products may have intentional splits for aesthetic purposes.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   84
Exterior Finishing



 4.26

 CONDITION
 EXTERIOR WOOD TRIM IS BOWED, TWISTED OR CUPPED

 Acceptable Performance/Condition
 Exterior wood trim may warp, twist or cup. Loose trim or trim that falls off is not acceptable.

 Warranty
 One-Year – Work and Materials
 Two-Year – Cladding Detachment, Displacement or Deterioration
 • Warping, twisting or cupping resulting from normal shrinkage of materials caused by drying
   after construction, or normal wear and tear are not covered by the statutory warranty.

 Action
 Trim not meeting the acceptable condition shall be repaired.

 Remarks
 None.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
85   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.27

CONDITION
PAINT ON REPAIRED AREAS DOESN’T MATCH

Acceptable Performance/Condition
Repainted areas shall match the original finished surface for colour, sheen and texture as closely as
possible and be a properly painted surface. The repainted area shall be assessed by viewing,
without magnification, from a minimum perpendicular distance of 1,500 mm under normal lighting
conditions and from a normal viewing position.

Warranty
One-Year – Work and Materials

Action
Repainted areas not meeting the acceptable condition shall be repaired.

Remarks
Exact matches cannot be reasonably expected due to aging and environmental soiling. The extent
of the repainting may have to be considered to ensure the match is as close as possible.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   86
Exterior Finishing



 4.28

 CONDITION
 EXTERIOR PAINT, STAIN OR CLEAR FINISH BLISTERS AND PEELS

 Acceptable Performance/Condition
 Exterior paint, stain or clear finishes shall not deteriorate to the extent of exposing the substrate
 beneath; surfaces subject to foot traffic are exempt from this requirement.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from normal wear and tear is not covered by the statutory warranty.

 Action
 Paint or stain not meeting the acceptable performance shall be repaired.

 Remarks
 Weathering of painted, stained or clear-coated exterior surfaces is normal. Discolouration of the
 wood beneath is evidence of failed clear finish. Excessive moisture in the substrate can contribute
 to premature finish deterioration.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
87   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.29

CONDITION
EXTERIOR PAINT OR STAIN HAS FADED

Acceptable Performance/Condition
Exterior paints and stains shall not fade or discolour in an uneven or random manner.

Warranty
One-Year – Work and Materials
• Damage resulting from normal wear and tear, improper maintenance, or alterations,
  deletions or additions by the homeowner is not covered by the statutory warranty.

Action
Exterior paints and stains not meeting the acceptable condition shall be repaired.

Remarks
Fading of exterior paints and stains is normal and the degree of fading depends on
environmental conditions, e.g. southern exposures. Exact matches of repainted areas
cannot be expected due to aging and environmental soiling of the original finish.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   88
Exterior Finishing



 4.30

 CONDITION
 MOULD OR MILDEW IS VISIBLE ON EXTERIOR PAINTED SURFACES

 Acceptable Performance/Condition
 Painted or finished surfaces shall be free of visible mould and mildew.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance or normal wear and tear is not covered
   by the statutory warranty.

 Action
 Exterior painted surfaces not meeting the acceptable performance shall be repaired.

 Remarks
 Mould or mildew is common in the natural environment. It can often form on painted surfaces
 and can usually be removed during normal home maintenance.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




     Construction Performance Guidelines
     Second Edition, effective December 1, 2003
89   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Exterior Finishing



4.31

CONDITION
LEAK IN EXTERIOR WALL

Acceptable Performance/Condition
The building envelope shall be constructed to prevent water entry.

Warranty
Two-Year – Building Envelope Water Penetration
Two-Year – Cladding Detachment, Displacement or Deterioration
• Water penetration resulting from improper maintenance or normal wear and tear is
  not covered by the statutory warranty.

Action
Building envelopes not meeting the acceptable condition shall be repaired.

Remarks
Joints and cracks in exterior wall surfaces and around openings shall be properly sealed
to prevent the entry of water. Caulking and sealants deteriorate under normal weather
conditions and should be checked regularly.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   90
Roofs



 5.1

 CONDITION
 ROOF RIDGE HAS SAGGED

 Acceptable Performance/Condition
 Roofs shall be constructed to ensure the ridge does not sag under normal design
 conditions in accordance with the Ontario Building Code.

 Warranty
 One-Year – Work and Materials
 Seven-Year – Major Structural Defect
 • Damage resulting from improper maintenance or additions, deletions or alterations
   made by the homeowner is excluded from the statutory warranty.

 Action
 Roofs not meeting the acceptable performance shall be repaired.

 Remarks
 Heavy loads of ice and snow can damage a roof. Normal home maintenance should
 include professional removal of heavy buildups of ice and snow.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
91     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.2

CONDITION
ROOF TRUSSES OR RAFTERS ARE BOWED

Acceptable Performance/Condition
Roof framing members shall be sized and installed in accordance with the Ontario Building Code.

Warranty
One-Year – Work and Materials
Two-Year – Ontario Building Code Health & Safety Violations
• Damage resulting from improper maintenance or additions, deletions or alterations made
  by the homeowner is excluded from the statutory warranty.

Action
Roof framing members not meeting the acceptable performance shall be repaired.

Remarks
Deflection due to normal loading and bowing due to normal drying of wood framing materials
is acceptable.
Heavy loads of ice and snow can damage a roof. Normal home maintenance should include
professional removal of heavy buildups of ice and snow.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   92
Roofs



 5.3

 CONDITION
 ROOF APPEARS WAVY

 Acceptable Performance/Condition
 Roof sheathing shall be sized and installed in accordance with the Ontario Building Code.

 Warranty
 One-Year – Work and Materials

 Action
 Roof sheathing not meeting the acceptable performance shall be repaired.

 Remarks
 Roof sheathing shall be installed with proper joint spacing and support. Waviness between
 framing members may occur even when sheathing is properly installed.
 Frost patterns on a roof can give the appearance of waviness without the condition existing
 (e.g. frost outline on sheathing joints and over roof framing members).

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
93     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.4

CONDITION
LEAKS DUE TO SNOW OR RAIN DRIVEN INTO THE ATTIC THROUGH LOUVRES OR VENTS

Acceptable Performance/Condition
Attic vents must be designed to prevent the entry of rain, snow and insects and they shall
be installed in accordance with the Ontario Building Code.

Warranty
One-Year – Ontario Building Code Violations
Two-Year – Building Envelope Water Penetration
• Water penetration resulting from improper maintenance or an act of God is excluded from
  the statutory warranty.

Action
Defective material or improper vent installation resulting in water penetration shall be repaired.

Remarks
During high wind pressures, slight amounts of precipitation may be driven into roof vents.
This condition is warranted only where there is a demonstrated defect in work or material
supplied by the builder.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   94
Roofs



 5.5

 CONDITION
 ROOF OR FLASHING LEAKS

 Acceptable Performance/Condition
 Roofs and their associated flashings shall allow no water penetration under normal weather
 conditions.

 Warranty
 One-Year – Ontario Building Code Violations
 Two-Year – Building Envelope Water Penetration
 • Water leakage resulting from improper maintenance or an act of God is excluded from the
   statutory warranty. Secondary damage to property or any personal injury resulting from
   the water penetration is also excluded from the statutory warranty.

 Action
 Defects allowing water penetration through the roof or any associated flashings shall be repaired.

 Remarks
 Ice dams can cause water leakage during the winter. This condition is warranted if the ice dam
 results from a demonstrated defect in work or material supplied by the builder. The homeowner
 must take immediate steps to prevent damage to their property and report any losses to their
 home insurance provider.
 See Appendix A5 “How to Conduct a Water Test” for more information.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
95     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.6

CONDITION
INADEQUATE ATTIC VENTILATION

Acceptable Performance/Condition
Attics shall be ventilated in accordance with the Ontario Building Code.

Warranty
Two-Year – Ontario Building Code Health & Safety Violations
• Damage caused by dampness or condensation due to failure by the homeowner to maintain
  adequate ventilation is excluded from the statutory warranty.

Action
Attics not meeting the acceptable condition shall be repaired.

Remarks
Roof vents should be kept free of obstructions. Inadequate attic ventilation can lead to heat
and moisture problems. Snow covering roof vents can obstruct ventilation.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   96
Roofs



 5.7

 CONDITION
 ICE BUILDUP ON THE ROOF

 Acceptable Performance/Condition
 Ice and icicles are a natural occurrence on roofs.

 Warranty
 None.
 • Damage caused by improper maintenance is not covered by the statutory warranty.

 Action
 The builder is not required to take any action.

 Remarks
 Ice dams and icicles occur when the roof surface is warm enough to melt the snow but the air
 temperature is cold enough to re-freeze the melt water. Natural weather patterns, building exposure,
 roof design and elevated attic temperatures, due to both the insulating effects of snow accumulation
 on the roof and air leakage from the interior of the building, can contribute to ice forming on roofs.
 Professional removal of buildups of ice and snow can help reduce the likelihood of water leaks.
 See section 5.5 “Roof or Flashing Leaks” for water leakage resulting from ice dams.
 This condition is warranted only where there is a demonstrated Ontario Building Code violation or a
 defect in work or material supplied by the builder.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
97     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.8

CONDITION
ROOF SHINGLES HAVE BLOWN OFF

Acceptable Performance/Condition
Roof shingles shall be installed according to the Ontario Building Code and the
manufacturer’s specifications.

Warranty
One-Year – Work and Materials
• Damage resulting from acts of God is not covered by the statutory warranty.

Action
Roof shingles not meeting the acceptable performance shall be repaired.

Remarks
Severe weather and wind gusts can sometimes exceed the design limitations of the shingles.
Different shingle types and materials have varying abilities to resist these forces.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   98
Roofs



 5.9

 CONDITION
 TABS ON ASPHALT SHINGLES ARE NOT LINED UP

 Acceptable Performance/Condition
 Shingles shall be installed to provide a generally uniform pattern when viewed from a normal
 viewing position on the ground from any given location.

 Warranty
 One-Year – Work and Materials

 Action
 Shingles not meeting the acceptable condition shall be repaired.

 Remarks
 The primary role of roofing is to protect the building from the weather. Slight variation in the
 appearance of the roof is acceptable.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
99     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.10

CONDITION
ASPHALT SHINGLES NOT SEALED

Acceptable Performance/Condition
Asphalt shingles and self-sealing asphalt shingles shall be secured according to the
Ontario Building Code and manufacturer’s specifications.

Warranty
One-Year – Work and Materials

Action
Shingles not meeting the acceptable condition shall be repaired.

Remarks
Asphalt shingles installed in temperatures below 5°C will seal when warmer temperatures
return. In the short term, unsealed shingles should not affect the weather protection provided
by the roof.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   100
Roofs



 5.11

 CONDITION
 ASPHALT SHINGLE EDGES ARE CURLED OR CUPPED

 Acceptable Performance/Condition
 Asphalt shingle edges and corners need not be completely flat. Edges and corners that curl
 or cup to expose the uncoloured portion of the shingle below are not acceptable.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from normal wear and tear is not covered by the statutory warranty.

 Action
 Shingles not meeting the acceptable condition shall be repaired.

 Remarks
 Adequate attic ventilation is necessary to prevent excessive solar heat buildup in the attic
 that can contribute to curling and cupping.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
101   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.12

CONDITION
ASPHALT SHINGLES EITHER DO NOT OVERHANG THE EDGE OF THE ROOF
OR HANG OVER TOO FAR

Acceptable Performance/Condition
Asphalt shingles shall overhang roof edges by not less than 12 mm according to the
Ontario Building Code; they shall not overhang the roof edge to the extent that they curl.

Warranty
One-Year – Work and Materials

Action
Shingle overhangs not meeting the acceptable condition shall be repaired.

Remarks
The edge of the roof includes the entire perimeter of the roof including gables.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   102
Roofs



 5.13

 CONDITION
 SHADING PATTERN IS VISIBLE ON AN ASPHALT SHINGLE ROOF

 Acceptable Performance/Condition
 At installation, asphalt shingle roofs shall be installed so that any dye lot difference
 is minimized to provide a uniform roof appearance, when viewed from a normal viewing
 position on the ground without magnification by reflected light.

 Warranty
 One-Year – Work and Materials

 Action
 Shingles not meeting the acceptable condition shall be repaired.

 Remarks
 Shading variations resulting from dye lot difference are acceptable.
 See section 5.14 “Variation in Colour After Repairs” for colour and shading of local repairs.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
103   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.14

CONDITION
VARIATION IN COLOUR AFTER REPAIRS

Acceptable Performance/Condition
Shingles used in local repairs shall be of similar type, texture and colour. Variation resulting
from fading or different dye lot is acceptable.

Warranty
One-Year – Work and Materials

Action
Shingles not meeting the acceptable condition shall be repaired.

Remarks
The primary role of roofing is to protect the building from the weather. Slight variation
in the colour of the roof after a local repair may be unavoidable.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   104
Roofs



 5.15

 CONDITION
 UNEVEN ROOF SHEATHING CAUSING VISIBLE IRREGULARITIES IN THE ROOF SURFACE

 Acceptable Performance/Condition
 Asphalt shingle surfaces need not be completely flat. The roof sheathing shall provide an even
 surface free from thickness variations, holes, and debris that produce visible irregularities in the
 finished roof. The roof shall be viewed from a normal viewing position on the ground without
 magnification by reflected light.

 Warranty
 One-Year – Work and Materials

 Action
 Roofs not meeting the acceptable condition shall be repaired.

 Remarks
 Visible irregularities shall be significant enough to suggest a defective condition.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
105   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.16

CONDITION
ROOFING NAILS ARE EXPOSED

Acceptable Performance/Condition
Roofing nails shall be covered by overlapping shingles or by sealing.

Warranty
One-Year – Work and Materials

Action
Roofs with nails not meeting the acceptable condition shall be repaired.

Remarks
The overlying shingle must cover the nails to ensure adequate weather protection.
Sealant applied to nails shall not detract from the overall uniform roof appearance.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   106
Roofs



 5.17

 CONDITION
 TEMPORARY SAFETY STRAPS LEFT ON ROOF

 Acceptable Performance/Condition
 Safety straps intended to be used only during construction shall not be left on the roof.

 Warranty
 One-Year – Work and Materials

 Action
 Temporary safety straps shall be removed.

 Remarks
 Temporary safety straps are used during construction and there is no need for them
 to remain on the roof after construction, unless required by other authorities.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
107   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.18

CONDITION
WATER IS TRAPPED UNDER ROOFING MEMBRANE

Acceptable Performance/Condition
Water shall not become trapped under built-up or single-ply roofing membranes.

Warranty
One-Year – Work and Materials
Two-Year – Building Envelope Water Penetration

Action
Roofing not meeting the acceptable condition shall be repaired.

Remarks
None.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   108
Roofs



 5.19

 CONDITION
 ASPHALT ROLL ROOFING IS BLISTERED BUT DOES NOT ADMIT WATER

 Acceptable Performance/Condition
 Roll roofing may blister under normal weather conditions. Blisters that result in water
 penetration are not acceptable.

 Warranty
 One-Year – Work and Materials

 Action
 Roofing not meeting the acceptable condition shall be repaired.

 Remarks
 Surface blistering of roll roofing may be caused by solar heating and humidity.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
109   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.20

CONDITION
STANDING WATER ON A FLAT ROOF

Acceptable Performance/Condition
Flat roofs shall be installed to drain water.
Standing water on roofs designed for water retention is acceptable.

Warranty
One-Year – Work and Materials

Action
Roofs not meeting the acceptable condition shall be repaired.

Remarks
Flat roofs typically are slow to drain and should be constructed to handle exposure to standing
water over short terms. Municipalities can require flow control devices to be installed on roof
drains. Some standing water is normal and should generally dissipate after a few days.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   110
Roofs



 5.21

 CONDITION
 EAVESTROUGHS OR DOWNSPOUTS LEAK

 Acceptable Performance/Condition
 Eavestroughs and downspouts shall not leak at joints.

 Warranty
 One-Year – Work and Materials

 Action
 Eavestroughs and downspouts not meeting the acceptable performance shall be repaired.

 Remarks
 Water hitting and dripping off the outside of eavestroughs and downspouts should not be
 mistaken for leakage.
 Seasonal conditions may affect the timing of repairs.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
111   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.22

CONDITION
EAVESTROUGHS OVERFLOW DURING NORMAL RAIN

Acceptable Performance/Condition
Eavestroughs shall be installed in accordance with municipal requirements (where applicable)
with a slope to downspouts or drains. Eavestroughs may overflow during a rain as a result of
converging water flows.

Warranty
One-Year – Work and Materials
• Damage resulting from normal wear and tear or an act of God is excluded from the
  statutory warranty.

Action
Eavestroughs not meeting the acceptable condition shall be repaired.
Overflow resulting from inadequate slope or non-conformance with municipal requirements
is subject to the statutory warranty.

Remarks
The homeowner shall keep eavestroughs and downspouts free from environmental debris
or physical damage that could cause blockage or restrict water flow.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   112
Roofs



 5.23

 CONDITION
 EAVESTROUGHS OR DOWNSPOUTS NOT PERFORMING PROPERLY

 Acceptable Performance/Condition
 Where provided, eavestroughs and downspouts shall collect water from the roof and drain
 it to grade. Where downspouts are not connected to a sewer, extensions shall be provided
 to carry rainwater away from the building in a manner that will prevent soil erosion.

 Warranty
 One-Year – Work and Materials

 Action
 Eavestroughs and downspouts not meeting the acceptable performance shall be repaired.

 Remarks
 Normal home maintenance includes keeping the eavestroughs and downspouts free of debris
 that can clog the system. Extensions may include splash pads set on the ground.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
113   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Roofs



5.24

CONDITION
EAVESTROUGHS DON’T DRAIN COMPLETELY

Acceptable Performance/Condition
Eavestroughs shall generally slope to drains.

Warranty
One-Year – Work and Materials
• Damage resulting from improper maintenance is not covered by the statutory warranty.

Action
Eavestroughs not meeting the acceptable condition shall be repaired.

Remarks
Some minimal amount of standing water is normal. Normal home maintenance includes keeping
the eavestroughs and downspouts free of debris that can clog the system.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   114
Roofs



 5.25

 CONDITION
 SKYLIGHT LEAKS

 Acceptable Performance/Condition
 Skylights shall be installed in accordance with the manufacturer’s specifications and shall not
 allow water penetration.

 Warranty
 Two-Year – Building Envelope Water Penetration
 • Damage resulting from dampness or condensation due to failure by the homeowner to
   maintain adequate ventilation is not covered by the statutory warranty.

 Action
 Skylights not meeting the acceptable performance shall be repaired.

 Remarks
 Condensation on the interior surfaces of a skylight may occur if indoor relative humidity is high.
 Condensation is not considered indicative of a defective condition.
 To test for water penetration, see Appendix A5 “How to Conduct a Water Test”.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
115   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Plumbing



6.1

CONDITION
INADEQUATE WATER SUPPLY

Acceptable Performance/Condition
Water supply from private water sources (e.g. wells) may fluctuate from time to time.
Water supply from municipal water sources may vary with the supplied pressure.

Warranty
None.

Action
None.

Remarks
Confirm proper operation of faucets and fixtures during the PDI and record any malfunction on the
PDI Form, to avoid any dispute about whether the damage was caused by the builder. The Ontario
Building Code requires flow control devices on faucets, showerheads, and fixtures for water
conservation purposes, which can affect the water flow.
After occupancy, the builder is not responsible for contamination or reduced water capacity from
private water sources provided it can be shown there was an adequate supply of potable water at
the time of occupancy.
Variations in pressure from municipal services can occur during peak usage times, from burst
water mains or fire protection services using the system.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   116
Plumbing



 6.2

 CONDITION
 THE DOMESTIC WATER SUPPLY SYSTEM DOES NOT DELIVER WATER

 Acceptable Performance/Condition
 The domestic water supply system supplied and installed by the builder shall be capable of
 delivering water from a municipal or private (well) source throughout the home.

 Warranty
 One-Year – Work and Materials on pumps supplying water from a private well
 Two-Year – Delivery and Distribution Systems
 • Damage resulting from improper maintenance or additions, deletions or alterations made by a
   homeowner is excluded from the statutory warranty.
 • Damage caused by municipal services or other utilities is excluded from the statutory warranty.

 Action
 Domestic water supply systems not meeting the acceptable performance shall be repaired.

 Remarks
 Conditions beyond the control of the builder, such as burst water mains and periods of drought
 affecting groundwater levels that disrupt or eliminate the water supply, are not covered by the
 statutory warranty. See 6.1 for Inadequate Water Supply.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
117    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Plumbing



6.3

CONDITION
PIPES ARE LEAKING

Acceptable Performance/Condition
Domestic water supply and drainpipes shall not leak.

Warranty
Two-Year – Delivery and Distribution Systems
• Damage resulting from improper maintenance or additions, deletions or alterations made by the
  homeowner is excluded from the statutory warranty.
• Secondary damage caused by defects, such as property damage or personal injury, is excluded
  from the statutory warranty.

Action
Pipes not meeting the acceptable performance shall be repaired.

Remarks
Condensation on piping should not be mistaken for a leaking pipe. Condensation on cold-water
supply pipes is not covered by the statutory warranty. High indoor humidity is the main cause of
condensation on pipes.
If a leak is detected in a water supply pipe, the main water supply valve should be turned off
immediately until the builder’s representative can assess the condition. For more information on
emergency situations, please refer to the Homeowner Information Package.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   118
Plumbing



 6.4

 CONDITION
 FAUCET OR FIXTURE IS LEAKING

 Acceptable Performance/Condition
 Faucets or plumbing fixtures shall not leak, drip or run on when fully closed or shut off.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance, normal wear and tear, or additions, deletions or
   alterations made by the homeowner is excluded from the statutory warranty.
 • Secondary damage caused by defects, such as property damage or personal injury, is excluded
   from the statutory warranty.

 Action
 Faucets or fixtures not meeting the acceptable performance shall be repaired.

 Remarks
 Confirm proper operation of faucets and fixtures during the PDI and record any malfunction on
 the PDI Form, to avoid any dispute about whether the damage was caused by the builder. Some
 manufacturers of plumbing products offer warranties on their products that extend beyond the
 one-year statutory warranty. If a leak occurs after the one-year statutory warranty, service may
 be available from the manufacturer.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
119    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Plumbing



6.5

CONDITION
PLUMBING PIPES ARE FROZEN AND/OR BURST

Acceptable Performance/Condition
Plumbing pipes shall be protected from freezing in accordance with the Ontario Building Code.

Warranty
Two-Year – Delivery and Distribution Systems
• Damage resulting from improper maintenance or additions, deletions or alterations made
  by the homeowner is excluded from the statutory warranty.
• Secondary damage caused by defects, such as property damage or personal injury, is
  excluded from the statutory warranty.

Action
Plumbing pipes not meeting the acceptable condition shall be repaired.

Remarks
Homes must be kept at temperatures to prevent freezing at all times. If this is not possible,
proper precautions should be taken to prevent freezing such as shutting off and draining the
water supply system.
For exterior hose bibs, shut off any associated interior valves and leave the exterior valve
open as part of a regular seasonal maintenance program. Garden hoses must also be
disconnected from the exterior hose bib.
If a burst pipe is detected in a water supply pipe, the main water supply valve should be
turned off immediately until the builder’s representative can assess the condition. For more
information on emergency situations, please refer to the Homeowner Information Package.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   120
Plumbing



 6.6

 CONDITION
 BATHTUB OR SHOWER LEAKS

 Acceptable Performance/Condition
 Bathtubs and showers shall be installed in accordance with manufacturer’s specifications
 so they do not leak.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance or additions, deletions or alterations made
   by the homeowner is excluded from the statutory warranty.
 • Secondary damage caused by defects, such as property damage or personal injury, is
   excluded from the statutory warranty.

 Action
 Bathtubs or showers not meeting the acceptable performance shall be repaired.

 Remarks
 Caulking and seals around bathtubs and shower enclosures and entry door seals require
 regular homeowner inspection and maintenance to prevent leaks.
 If a leak is detected in a water supply pipe, the main water supply valve should be turned off
 immediately until the builder’s representative can assess the condition. For more information
 on emergency situations, please refer to the Homeowner Information Package.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
121    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Plumbing



6.7

CONDITION
CONDENSATION APPEARS ON WATER SUPPLY PIPES AND TOILETS

Acceptable Performance/Condition
Condensation on water supply pipes and toilets may occur when indoor relative humidity is high.

Warranty
None.

Action
None.

Remarks
Condensation may appear on water supply lines and toilets from time to time and is normal.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   122
Plumbing



 6.8

 CONDITION
 NOISY WATER PIPES OR “WATER HAMMER”

 Acceptable Performance/Condition
 Water supply pipes shall be installed to minimize the effects of water hammer and in accordance
 with the Ontario Building Code.
 Drainage pipes shall be installed in accordance with the Ontario Building Code.

 Warranty
 Two-Year – Delivery and Distribution Systems
 • Damage resulting from improper maintenance or additions, deletions or alterations made by the
   homeowner is excluded from the statutory warranty.
 • Secondary damage caused by defects, such as property damage or personal injury, is excluded
   from the statutory warranty.

 Action
 Plumbing pipes not meeting the acceptable performance shall be repaired.

 Remarks
 Hammering of water supply pipes during normal operation may indicate a problem and
 should be investigated. A sudden thump or bang of water supply pipes when a faucet or fixture
 is closed abruptly is normal and not covered by the statutory warranty.
 Slight “ticking” sounds coming from copper hot water supply pipes as they expand are normal
 and are not covered by the statutory warranty.
 The sound of water flowing through drainage pipes is normal and not covered by the
 statutory warranty.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
123    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Plumbing



6.9

CONDITION
DEFECTIVE PLUMBING FIXTURES, APPLIANCES OR TRIM FITTINGS

Acceptable Performance/Condition
Plumbing fixtures, appliances or trim fittings shall be free of both visual and performance defects.

Warranty
One-Year – Work and Materials
• Damage resulting from improper maintenance is excluded from the statutory warranty.

Action
Defective products shall be repaired or replaced.

Remarks
Confirm proper operation of plumbing fixtures during the PDI and record any malfunction on the
PDI Form, to avoid any dispute about whether the damage was caused by the builder. Plumbing
fixtures, appliances or trim fittings must be maintained in accordance with the manufacturer’s
instructions.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   124
Plumbing



 6.10

 CONDITION
 CRACKING OR CHIPPING OF PORCELAIN, ENAMEL OR FIBREGLASS SURFACES

 Acceptable Performance/Condition
 Surfaces exposed to view shall be free from visible damage at the time of the PDI.

 Warranty
 One-Year – Work and Materials
 • Damage not recorded on the PDI Form is excluded from the statutory warranty, unless the
   homeowner is able to establish that the damage was caused by the builder.
 • Damage resulting from normal wear and tear is excluded from the statutory warranty.

 Action
 Visible damage shall be repaired.

 Remarks
 Identify any damaged porcelain, enamel or fibreglass surfaces on the PDI Form to avoid any
 dispute about whether the damage was caused by the builder. Maintain porcelain, enamel or
 fibreglass surfaces in accordance with the manufacturer’s instructions.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
125   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Plumbing



6.11

CONDITION
LIGHTWEIGHT (FIBREGLASS AND ACRYLIC) BATHTUB OR SHOWER BASE
FLEXES AND CREAKS

Acceptable Performance/Condition
Lightweight bathtubs and showers may flex and creak when installed in accordance with
manufacturer’s specifications.

Warranty
One-Year – Work and Materials

Action
Bathtubs or showers not meeting the acceptable condition shall be repaired.

Remarks
Fibreglass and acrylic bathtubs and shower enclosures are lightweight yet strong. Flexing or
creaking sounds can often be heard especially in large soaker-type tubs as they are filled and
emptied. These fixtures are designed to withstand this type of flexing; it does not generally
represent a manufacturing or installation defect.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   126
Plumbing



 6.12

 CONDITION
 MANUFACTURED SOLID-SURFACE COUNTERTOP (INTEGRATED BASIN)
 CRACKS AT THE DRAIN

 Acceptable Performance/Condition
 Manufactured solid-surface countertops shall be installed to prevent stress cracking and in
 accordance with the manufacturer’s specifications.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance or additions, deletions or alterations made
   by the homeowner is excluded from the statutory warranty.

 Action
 Manufactured solid-surface countertops not meeting the acceptable performance shall be repaired.

 Remarks
 Identify any damaged countertops during the PDI and record any damage on the PDI Form,
 to avoid any dispute about whether the damage was caused by the builder. Manufactured
 solid-surface countertops can be brittle and damaged by impact. Over-tightening of drains
 or fasteners may cause stress cracks. Care should be taken when cleaning or servicing to
 prevent cracking or chipping.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
127   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Plumbing



6.13

CONDITION
TOILET TAKES MORE THAN ONE FLUSH TO EMPTY

Acceptable Performance/Condition
Toilets (water closets) shall flush waste into the drainage system.

Warranty
One-Year – Work and Materials
• Drain restrictions due to improper maintenance are excluded from the statutory warranty.

Action
Where defective installation or product is determined repairs shall be made.

Remarks
Newer low-volume toilets, which are required for new homes by the Ontario Building Code,
use less water to flush waste than older models, making their operation more sensitive to
the effects of the:
• amount of waste
• amount of paper
• volume of water in the tank
As a result, multiple flushes may be required.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   128
Plumbing



 6.14

 CONDITION
 SEWER, DRAINS OR FIXTURES BLOCKED

 Acceptable Performance/Condition
 Sanitary drainage systems and fixtures shall drain waste products to a public sanitary sewer
 or private sewage disposal system without interruption.

 Warranty
 One-Year – Work and Materials
 Two-Year – Delivery and Distribution Systems
 Seven-Year – Major Structural Defect (private sewage disposal systems only)
 • Damage caused by blocked sanitary drainage systems resulting from vegetation
   (e.g., tree roots), alterations made by the homeowner, improper maintenance or use,
   or caused by municipal services or other utilities is excluded from the warranty.

 Action
 • Complete failure of sanitary drainage systems is considered to be an emergency.
 • The builder shall effect repairs within 24 hours of receiving notice from the homeowner.
   If the homeowner cannot contact the builder, the homeowner must follow the “Emergency
   Situations” rules in the Homeowner Information Package.
 • If the homeowner expects to be reimbursed for repairs, the repairs must be documented
   to clearly identify the nature of the problem and repair and be illustrated with photographs.
 • The builder is only responsible for reimbursement where the cause of failure results
   from work or material supplied by the builder. In all other cases, the homeowner is
   responsible for the cost of repairs.

 Remarks
 With respect to septic systems, improper maintenance by the homeowner includes:
 • Connection of sump pump, roof drains, or backwash from a water conditioner into the system.
 • Placement of non-biodegradable items into the system.
 • Use of a food waste disposal.
 • Placement of surfaces not permeable to water over the disposal area of the system.
 • Allowing vehicles to drive or park over the disposal area of the system.
 • Failure to pump out the septic tank periodically, as required.
 • Use that exceeds the system’s design standards.

 Words in italics are defined in the “Terminology” section on pages 15-17.




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
129   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Electrical



7.1

CONDITION
FUSES BLOW OR CIRCUIT BREAKERS TRIP

Acceptable Performance/Condition
Electrical circuits shall be installed in accordance with the Ontario Electrical Code.

Warranty
Two-Year – Delivery and Distribution Systems
• Damage resulting from improper maintenance or additions, deletions or alterations made
  by the homeowner is excluded from the statutory warranty.
• Secondary damage caused by defects, such as property damage or personal injury,
  is excluded from the statutory warranty.

Action
Electrical circuits not meeting the acceptable performance shall be repaired.

Remarks
Circuit breakers protect electrical wiring from overloading. Frequent tripping of circuit breakers
or blown fuses could result from faulty appliances and should be investigated. Some appliances
have special power requirements.
Care should be taken not to overload or bypass electrical circuits. Personal injury or fire can
result. Typical household wiring is installed to accommodate residential electrical loads.
Specific requirements should be discussed with the builder prior to installation.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   130
Electrical



 7.2

 CONDITION
 GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) TRIPS FREQUENTLY

 Acceptable Performance/Condition
 GFCIs shall be installed in accordance with the Ontario Electrical Code.

 Warranty
 Two-Year – Delivery and Distribution Systems
 • Damage resulting from improper maintenance or additions, deletions or alterations made
   by the homeowner is excluded from the statutory warranty.

 Action
 Electrical circuits protected by a GFCI not meeting the acceptable condition shall be repaired.

 Remarks
 GFCIs are sensitive safety devices installed to provide protection against electrical shock,
 especially in wet areas. These devices can be tripped and reset easily. Frequent tripping may
 indicate an appliance fault and should be investigated.
 GFCIs are often interconnected with plain receptacles to protect an entire circuit.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
131    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Electrical



7.3

CONDITION
ELECTRICAL OUTLETS OR SWITCHES DON’T WORK

Acceptable Performance/Condition
Electrical outlets and switches shall be installed in accordance with manufacturer’s specifications
and the Ontario Electrical Code.

Warranty
Two-Year – Delivery and Distribution Systems
• Damage resulting from improper maintenance or additions, deletions or alterations made
  by the homeowner is excluded from the statutory warranty.
• Secondary damage caused by defects, such as property damage or personal injury,
  is excluded from the statutory warranty.

Action
Electrical outlets and switches not meeting the acceptable performance shall be repaired.

Remarks
Test the operation of electrical outlets and switches during the PDI and record damage on the
PDI Form, to avoid any dispute about whether the damage was caused by the builder. Check the
electrical circuit panel when a receptacle or switch fails to work.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   132
Electrical



 7.4

 CONDITION
 ELECTRICAL FIXTURE DOESN’T WORK

 Acceptable Performance/Condition
 Electrical fixtures supplied and installed by the builder shall be installed in accordance
 with the manufacturer’s specifications and the Ontario Electrical Code.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance or additions, deletions or alterations made
   by the homeowner is excluded from the statutory warranty.
 • Secondary damage caused by defects, such as property damage or personal injury,
   is excluded from the statutory warranty.

 Action
 Electrical fixtures not meeting the acceptable performance shall be repaired.

 Remarks
 Identify damaged electrical fixtures on the PDI Form to avoid any dispute about whether the
 damage was caused by the builder. Check the electrical circuit panel when a receptacle or
 switch fails to work.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
133    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Electrical



7.5

CONDITION
RECEPTACLE/SWITCH COVER PLATE IS NOT FLUSH WITH THE WALL

Acceptable Performance/Condition
Electrical receptacles/switches shall be installed so that the cover plate sits generally flush
with the adjacent wall surface.

Warranty
One-Year – Work and Materials
• Damage resulting from improper maintenance or additions, deletions or alterations made
  by the homeowner is excluded from the statutory warranty.

Action
Receptacles/switch cover plates not meeting the acceptable condition shall be repaired.

Remarks
None.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   134
Electrical



 7.6

 CONDITION
 EXHAUST FAN DUCT TERMINATES IN ATTIC OR CRAWL SPACE

 Acceptable Performance/Condition
 Exhaust fans shall be ducted to the exterior in accordance with the Ontario Building Code.

 Warranty
 Two-Year – Ontario Building Code Health and Safety Violations
 • Damage resulting from improper maintenance or additions, deletions or alterations made
   by the homeowner is excluded from the statutory warranty.

 Action
 Exhaust fans not meeting the acceptable performance shall be repaired.

 Remarks
 Exhaust fans and clothes dryers should never be ducted into heated or unheated enclosed
 spaces such as basements, attics and soffits, or attached garages. Moisture buildup in these
 areas can cause damage.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
135    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Electrical



7.7

CONDITION
INTERIOR LIGHT FIXTURE TARNISHED

Acceptable Performance/Condition
Interior light fixtures supplied and installed by the builder shall not tarnish.

Warranty
One-Year – Work and Materials
• Damage resulting from improper maintenance or additions, deletions or alterations made
  by the homeowner is excluded from the statutory warranty.

Action
Light fixtures not meeting the acceptable condition shall be repaired.

Remarks
Discolouration may occur due to the normal operation of the fixture. Exceeding the
manufacturer’s specification for bulb wattage may also cause discolouration, which is not
covered by the statutory warranty.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   136
Electrical



 7.8

 CONDITION
 CEILING FAN VIBRATES AND IS NOISY

 Acceptable Performance/Condition
 Ceiling fans shall be installed and maintained in accordance with the manufacturer’s
 installation instructions.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance, normal wear and tear, or additions, deletions
   or alterations made by the homeowner is excluded from the statutory warranty.

 Action
 Ceiling fans not meeting the acceptable performance shall be repaired.

 Remarks
 Some vibration is normal. Ceiling fans can operate at high speeds and can become
 unbalanced, resulting in excessive vibration. Ceiling fans require regular maintenance.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
137    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Climate Control



8.1

CONDITION
DRAFT FELT AT ELECTRICAL OUTLET

Acceptable Performance/Condition
Electrical boxes on exterior walls that penetrate the air barrier system shall be installed to
prevent air infiltration.

Warranty
One-Year – Work and Materials

Action
Electrical boxes not meeting the acceptable condition shall be repaired.

Remarks
Some drafts may occur around electrical outlets or receptacles on exterior walls, particularly
when it is cold or windy. Convection air movement may simulate draft conditions.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   138
Interior Climate Control



 8.2

 CONDITION
 AIR INFILTRATION THROUGH WINDOWS AND DOORS

 Acceptable Performance/Condition
 Windows and doors shall meet the rating for weathertightness required by the
 Ontario Building Code.

 Warranty
 One-Year – Work and Materials

 Action
 Ensure the window or door has been tested to meet the required weathertightness rating.
 Adjust weatherstripping and/or hardware to reduce air leakage by ensuring positive contact
 along the weather seal.

 Remarks
 Doors and windows must be properly closed to ensure positive contact with weatherstripping.
 Doors and windows are manufactured to meet specifications for weathertightness and are
 designed to withstand reasonable wind loads. Minor air infiltration may occur during very windy
 conditions.
 Weatherstripping becomes worn with use and should be inspected and replaced by the
 homeowner on a regular basis.
 Interior air movement caused by convection should not be confused with actual air leakage
 through the window and doors.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
139    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Climate Control



8.3

CONDITION
KITCHEN OR BATH FANS ALLOW COLD AIR INFILTRATION OR DRAFTS

Acceptable Performance/Condition
Kitchen and bath exhaust fans shall be installed with backdraft dampers as per manufacturer’s
specifications.

Warranty
One-Year – Work and Materials
• Damage resulting from improper maintenance or additions, deletions or alterations made
  by the homeowner is excluded from the statutory warranty.

Action
Kitchen and/or bath exhaust fans not meeting the acceptable condition shall be repaired.

Remarks
Because they are connected to the exterior by a duct, ventilation fans are indirectly open to
outside air. Even though these types of fans come equipped with dampers, they are not completely
effective at eliminating cold air infiltration. Sometimes they can become obstructed and not close
fully. As part of regular home maintenance, vent terminations on exterior walls should be inspected
periodically to ensure the openings are not obstructed (e.g. by birds or other animals).

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   140
Interior Climate Control



 8.4

 CONDITION
 CONDENSATION IN ATTIC SPACE

 Acceptable Performance/Condition
 Condensation may occur in attics but these occurrences should be infrequent and without any
 adverse effect on the building.

 Warranty
 Two-Year – Ontario Building Code Health & Safety Violations
 • Damage caused by dampness or condensation due to failure by the homeowner to maintain
   adequate ventilation is excluded from the statutory warranty.

 Action
 Adequate ventilation equipment shall be installed in accordance with the Ontario Building Code.

 Remarks
 Attic spaces shall be ventilated in accordance with the Ontario Building Code. Condensation in
 attics may indicate either a lack of ventilation through the attic or a source of moisture within the
 attic space.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
141    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Climate Control



8.5

CONDITION
CONDENSATION AND/OR FROST ON WINDOWS

Acceptable Performance/Condition
Condensation may occur on interior window surfaces.

Warranty
None.
• Damage caused by dampness or condensation due to failure by the homeowner to maintain
  adequate ventilation is excluded from the statutory warranty.

Action
None.

Remarks
Condensation occurs when water vapour in indoor air contacts cool surfaces such as window
glass. Condensation on interior window surfaces is common during cold seasons. When outdoor
temperatures are well below freezing, ice may form at the bottom of the window.
Since it is important for homeowners to maintain proper humidity levels within the home to
prevent damage to other components such as hardwood flooring and for physical health,
some condensation on windows may be expected. Indoor humidity levels may be controlled
by dehumidification, ventilation or air conditioning.
Interior air moving over the windows can help control condensation. Heavy draperies or window
coverings that cover windows and block heat diffusers can prevent air flow.
Running the furnace fan continuously can also help to control condensation on windows.
See Appendix A3 “Moisture and Windows”.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   142
Interior Climate Control



 8.6

 CONDITION
 CONDENSATION ON INTERIOR DUCTWORK AND AIR HANDLING EQUIPMENT

 Acceptable Performance/Condition
 Condensation may occur on indoor ductwork and air handling equipment.

 Warranty
 None.
 • Damage caused by dampness or condensation due to failure by the homeowner to maintain
   adequate ventilation is excluded from the statutory warranty.

 Action
 None.

 Remarks
 This condition may occur in the summer when air conditioning equipment is operating or in winter
 when ducts are chilled by incoming outdoor air. For example, condensation may occur on range
 hood exhaust ducts during cold outdoor temperatures.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
143    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Climate Control



8.7

CONDITION
INSUFFICIENT INSULATION

Acceptable Performance/Condition
Insulation shall be installed in accordance with the Ontario Building Code.

Warranty
One-Year – Work and Materials
Two-Year – Ontario Building Code Health & Safety Violations

Action
Insulation levels not meeting the acceptable condition shall be repaired.

Remarks
Several factors affect living space temperatures:
a) Proper installation of insulation shall include correct placement behind electrical boxes,
   backing studs, corner framing and wiring, and around window and door openings.
b) Directional orientation – north-facing rooms are generally cooler than south-facing rooms.
c) Windows – glass has little insulating value and allows more heat to escape from the room.
d) Rooms over garages – have insulated floors that lose heat to the unheated garage below.
e) Airflow – free airflow from the supply outlet in a room to a return inlet or undercut door is
   essential. Generally, a minimum 25 mm space under interior doors above the finished floor
   covering should be provided.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   144
Interior Climate Control



 8.8

 CONDITION
 HEATING, VENTILATING OR AIR CONDITIONING (HVAC) SYSTEMS
 NOT INSTALLED PROPERLY

 Acceptable Performance/Condition
 HVAC appliances shall be installed to meet the manufacturer’s specifications and the Ontario
 Building Code. Ductwork and piping shall be joined and supported to maintain joint integrity.

 Warranty
 One-Year – Work and Materials
 Two-Year – Ontario Building Code Health & Safety Violations
 Two-Year – Heating Delivery and Distribution Systems
 • Damage resulting from alterations, deletions or additions by the homeowner, or improper
   maintenance, is excluded from the statutory warranty.

 Action
 Where builder-supplied and -installed appliances, ductwork and piping do not meet the acceptable
 performance, repairs shall be made.

 Remarks
 Confirm proper operation of the HVAC system during the PDI. Defects discovered after the PDI
 will be covered by the statutory warranty if they result from the builder’s work. Appliances such as
 the furnace and water heater are located at the discretion of the builder within the requirements of
 the governing authority.
 Duct tape is not generally required.
 For equipment performance requirements see sections 8.9 “Inadequate Heating” and 8.10
 “Inadequate Cooling”.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
145    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Climate Control



8.9

CONDITION
INADEQUATE HEATING

Acceptable Performance/Condition
Heating systems shall be capable of maintaining an indoor air temperature of:
a) 22°C in living spaces and unfinished basements
b) 15°C in crawl spaces;
at the design temperature for the geographical location.

Warranty
One-Year – Work and Materials
Two-Year – Delivery and Distribution Systems
• Damage resulting from alterations, deletions or additions made by the homeowner and
  from improper maintenance is excluded from the statutory warranty.

Action
Where the heating system is not capable of maintaining the prescribed temperature, repairs
shall be made.

Remarks
Several factors affect living space temperatures:
a) Directional orientation – north-facing rooms are generally cooler than south-facing rooms.
b) Windows – glass has little insulating value and allows more heat to escape from the room.
c) Rooms over garages – have insulated floors that lose heat to the unheated garage below.
d) Airflow – free airflow from the supply outlet in a room to a return inlet or undercut door is
   essential. Generally, a minimum 25 mm space under interior doors above the finished floor
   covering should be provided.
e) Personal preference – personal comfort differs between individuals.
Balancing the air delivery system may not completely compensate for the effects of these factors.
In determining the temperature of a room, measurements shall be taken in the center of the
room at 1,500 mm above the floor after the heating system has been running continuously for
at least 20 minutes.
Heat loss calculations and duct designs assist in determining the furnace size and adequacy
of the heating system.

Words in italics are defined in the “Terminology” section on pages 15-17.

Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   146
Interior Climate Control



 8.10

 CONDITION
 INADEQUATE COOLING

 Acceptable Performance/Condition
 Cooling systems shall be capable of maintaining an indoor air temperature of 24°C at the design
 temperature for the geographical location.

 Warranty
 One-Year – Work and Materials
 Two-Year – Delivery and Distribution Systems
 • Defects in materials, design and work supplied by the homeowner, and damage resulting from
   improper maintenance, or from alterations, deletions or additions made by the homeowner are
   excluded from the statutory warranty.

 Action
 Where the cooling system is not capable of achieving the acceptable performance, repairs shall
 be made.

 Remarks
 Sustained high outdoor temperatures exert large loads on cooling equipment; indoor temperatures
 will rise until outdoor temperatures return to design levels. Skylights and large window areas can
 allow sunlight and heat to transfer easily into the home. Temperatures tend to vary in a multi-storey
 home due to normal air movement patterns. Heat gain calculations and duct designs assist in
 determining the equipment size and adequacy of the cooling system.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
147   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Climate Control



8.11

CONDITION
NOISY DUCTWORK

Acceptable Performance/Condition
Ductwork may make noise as it expands and contracts during heating and cooling cycles.

Warranty
None.

Action
None.

Remarks
None.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   148
Interior Climate Control



 8.12

 CONDITION
 DUCTWORK MAKES NOISE WHEN FLOOR IS WALKED ON –
 COMMONLY KNOWN AS “OIL CANNING”

 Acceptable Performance/Condition
 Ductwork shall be constructed and installed to prevent “oil canning”.

 Warranty
 One-Year – Work and Materials
 • Damage due to normal shrinkage of materials caused by drying after construction is not
   covered by the statutory warranty.

 Action
 Ductwork not meeting the acceptable performance shall be repaired.

 Remarks
 Weight transfer on floors over metal ductwork can sometimes result in a temporary deflection
 of the metal ductwork. Shrinkage of floor joists may cause “oil canning”.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
149   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Climate Control



8.13

CONDITION
NOISE CAN BE HEARD AT REGISTER

Acceptable Performance/Condition
Floor registers and cold air return grilles shall be installed to prevent rattling.

Warranty
One-Year – Work and Materials
• Damage resulting from improper maintenance, or from additions, deletions or alterations made
  by the homeowner is excluded from the statutory warranty.

Action
Floor registers or cold air return grilles not meeting the acceptable condition shall be repaired.

Remarks
The sound of air movement at floor registers or cold air return grilles is normal, but they should
not rattle under normal use.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   150
Interior Climate Control



 8.14

 CONDITION
 DUCTWORK COMES APART

 Acceptable Performance/Condition
 Ductwork shall be joined and supported to prevent separation or detachment and maintain
 joint integrity.

 Warranty
 Two-Year – Delivery and Distribution Systems
 • Damage resulting from improper maintenance, or from additions, deletions or alterations made
   by the homeowner is excluded from the statutory warranty.

 Action
 Ductwork not meeting the acceptable condition shall be repaired.

 Remarks
 None.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
151   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Climate Control



8.15

CONDITION
CONDENSATE LINE IS BLOCKED

Acceptable Performance/Condition
Condensate lines from furnaces, air conditioning condenser coils and heat recovery ventilators
shall be free from blockage.

Warranty
One-Year – Work and Materials
• Damage resulting from normal wear and tear or improper maintenance is excluded from the
  statutory warranty.

Action
Condensate lines not meeting the acceptable condition shall be repaired.

Remarks
Where conditions permit, confirm the proper operation of the furnace, air conditioner and heat
recovery ventilators during the PDI and record any malfunction on the PDI Form, to avoid any
dispute about whether the damage was caused by the builder. Condensate lines should be
inspected and cleaned as part of regular home maintenance.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   152
Interior Climate Control



 8.16

 CONDITION
 AIR CONDITIONING COOLANT LINE LEAKS

 Acceptable Performance/Condition
 Air conditioning systems supplied and installed by the builder shall not leak.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance, or from additions, deletions or alterations made
   by the homeowner is excluded from the statutory warranty.

 Action
 Air conditioning systems not meeting the acceptable condition shall be repaired.

 Remarks
 None.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
153   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Climate Control



8.17

CONDITION
THERE ARE GAPS BETWEEN HEAT DIFFUSERS, COLD AIR RETURN GRILLES AND
VENTILATION GRILLES AND THE ADJACENT SURFACE

Acceptable Performance/Condition
Heat diffusers, cold air return grilles and ventilation intake grilles shall be installed securely and
be generally flush with the adjacent surface. Minor gaps between the diffuser or grille and the
adjacent surface are acceptable.

Warranty
One-Year – Work and Materials
• Damage resulting from improper maintenance, or from additions, deletions or alterations made
  by the homeowner is excluded from the statutory warranty.

Action
Heat diffusers, cold air return grilles and ventilation grilles not meeting the acceptable condition
shall be repaired.

Remarks
None.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   154
Wall and Ceiling Finish



 9.1

 CONDITION
 CEILING IS UNEVEN

 Acceptable Performance/Condition
 Within a room or space, ceilings shall appear uniform when viewed from a normal viewing
 position under normal lighting conditions.
 Where an isolated sag, bulge or area of waviness appears and is not a structural problem, the
 variation from the specified plane shall not exceed ±12 mm.

 Warranty
 One-Year – Work and Materials
 • Undulations caused by normal shrinkage of materials due to drying after construction are
   excluded from the statutory warranty.

 Action
 Sags or waves in ceilings greater than the acceptable performance shall be repaired.

 Remarks
 Even when installed according to the Ontario Building Code, it is not unusual to see undulation
 in drywalled ceilings due to joint finishing. This occurrence can be exaggerated by particular
 or critical lighting conditions and glossy finishes. Spray-applied textures and matte finishes
 minimize this condition.
 Some undulations may also be caused by truss uplift and applying ceiling drywall over major
 structural components such as beams. See section 9.5 “Ceiling/Wall Joint Separation Commonly
 Referred to as Truss Uplift”.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
155    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall and Ceiling Finish



9.2

CONDITION
CEILING TEXTURE IS UNEVENLY APPLIED

Acceptable Performance/Condition
In a room or area, applied ceiling texture (i.e. stipple) shall appear generally uniform when
viewed from a normal viewing position under normal lighting conditions.

Warranty
One-Year – Work and Materials

Action
Ceiling texture not meeting the acceptable condition shall be repaired.

Remarks
Minor variation in texture is normal with randomly applied finishing materials.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   156
Wall and Ceiling Finish



 9.3

 CONDITION
 GYPSUM WALLBOARD CORNERS ARE UNEVEN

 Acceptable Performance/Condition
 Gypsum wallboard corners shall appear generally even and uniform when viewed under
 normal lighting conditions from a normal viewing position.

 Warranty
 One-Year – Work and Materials

 Action
 Joints not meeting the condition shall be repaired.

 Remarks
 Minor waviness may be more apparent in corners that are not right-angled and is acceptable.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
157    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall and Ceiling Finish



9.4

CONDITION
CRACKS IN INTERIOR WALL AND CEILING SURFACES

Acceptable Performance/Condition
Interior drywall shall be installed to minimize cracking of joints, corners and corner beads.

Warranty
One-Year – Work and Materials
• Cracks resulting from normal shrinkage of materials due to drying after construction are
  excluded from the statutory warranty.

Action
Only warranted cracks shall be repaired and refinished to match original builder-applied
finish as closely as possible.

Remarks
Cracks are not unusual in drywall compound at joints, particularly at corners. Most cracks are a
result of normal shrinkage and are generally not warranted. The repair of normal shrinkage cracks
is at the builder’s discretion and sanding and repainting is not required. Builder’s specific policies
with respect to drywall repair will vary. These repairs are best left until the framing has settled.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   158
Wall and Ceiling Finish



 9.5

 CONDITION
 CEILING/WALL JOINT SEPARATION COMMONLY REFERRED TO AS “TRUSS UPLIFT”

 Acceptable Performance/Condition
 Cracks resulting from normal shrinkage are acceptable; crack width in excess of 4 mm is
 not acceptable.

 Warranty
 One-Year – Work and Materials
 • Cracks resulting from normal shrinkage of materials caused by drying after construction
   are excluded from the statutory warranty.

 Action
 Cracks in excess of the acceptable condition shall be repaired.

 Remarks
 Truss uplift may occur when outdoor temperatures are considerably colder than indoor
 temperatures. It can appear as a minor crack or a larger gap. Repairs should be deferred
 until such time as the truss returns to its original position.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
159    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall and Ceiling Finish



9.6

CONDITION
DRYWALL SURFACE BLEMISHES INCLUDING NAIL/SCREW POPS, BLISTERS IN TAPED
JOINTS, TROWEL MARKS, EXCESS JOINT COMPOUND AND DENTS OR GOUGES

Acceptable Performance/Condition
Interior finished drywall (excluding garages and unfinished areas) shall be free from damage
(dents and gouges) at the time of the PDI and be installed according to the Ontario Building Code.
Blemishes readily noticeable when viewed under normal lighting conditions from a normal viewing
position 1,800 mm perpendicular distance from the wall surface are unacceptable.

Warranty
One-Year – Work and Materials
• Nail pops resulting from normal shrinkage of materials due to drying after construction are
  excluded from the statutory warranty.
• Damaged areas of drywall not recorded on the PDI Form are excluded from the statutory warranty
  unless the homeowner is able to establish that the damage was caused by the builder.

Action
Only warranted drywall surface blemishes shall be repaired and refinished to match original
builder-applied finish as closely as possible.

Remarks
Identify any damaged drywall surfaces (dents and gouges) on the PDI Form to avoid any dispute
about whether the damage was caused by the builder. Surface blemishes in drywall are not unusual
at joints and at corners. The repair of surface blemishes resulting from normal shrinkage is at the
builder’s discretion and sanding and repainting is not required. Builder’s specific policies with
respect to drywall repairs will vary. Often these repairs are best left until the framing has settled.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   160
Wall and Ceiling Finish



 9.7

 CONDITION
 TEXTURE OF PAINTED GYPSUM WALLBOARD VARIES

 Acceptable Performance/Condition
 Variations in the surface texture of finished gypsum wallboard are normal.

 Warranty
 None.

 Action
 None.

 Remarks
 Wall and ceiling surfaces of gypsum wallboard consist of paper and joint compound. These
 materials accept paint finishes differently. Variations in texture of the final finish may result and
 are normal.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
161    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall and Ceiling Finish



9.8

CONDITION
FINISHED SURFACE IS ROUGH

Acceptable Performance/Condition
Surfaces that are touched during normal use shall be uniformly smooth. Surfaces not touched
during normal use shall appear smooth when viewed without magnification, from a minimum
distance of 1,500 mm under normal lighting conditions and from a normal viewing position.

Warranty
One-Year – Work and Materials

Action
Surfaces not meeting the acceptable condition shall be made smooth and refinished.

Remarks
The open grain in some wood surfaces tends to show a rough appearance yet feel smooth;
this is a natural property of wood and is acceptable.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   162
Wall and Ceiling Finish



 9.9

 CONDITION
 PAINT FINISH IS UNACCEPTABLE

 Acceptable Performance/Condition
 A properly painted surface shall be produced on every exposed surface where a painted finish is
 specified. A properly painted surface shall be assessed by viewing, without magnification, from a
 minimum perpendicular distance of 1,500 mm under normal lighting conditions and from a normal
 viewing position.

 Warranty
 One-Year – Work and Materials

 Action
 Where a properly painted surface is not achieved repairs shall be made.

 Remarks
 Natural lighting conditions throughout the day may change the appearance of the properly painted
 surface. Brush marks are acceptable in cut-in areas and on trim and may vary in appearance with
 paint type. Repainted areas shall match the original finished surface for colour, sheen and texture
 as closely as possible.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
163    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall and Ceiling Finish



9.10

CONDITION
CLEAR INTERIOR FINISHES HAVE DETERIORATED

Acceptable Performance/Condition
Clear interior finishes shall not deteriorate to the extent that they expose the substrate beneath.

Warranty
One-Year – Work and Materials
• Damage resulting from normal wear and tear is excluded from the statutory warranty.

Action
Clear finishes not meeting the acceptable performance shall be repaired.

Remarks
Use of inappropriate household cleaners can sometimes contribute to discolouration and
premature deterioration of finishes.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   164
Wall and Ceiling Finish



 9.11

 CONDITION
 PAINT IS SPLATTERED ON SURFACES NOT INTENDED TO BE PAINTED

 Acceptable Performance/Condition
 Interior surfaces not intended to be painted shall not have paint splatters when viewed
 under normal lighting conditions from a normal viewing position.

 Warranty
 One-Year – Work and Materials

 Action
 Surfaces not meeting acceptable condition shall be repaired.

 Remarks
 None.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
165   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall and Ceiling Finish



9.12

CONDITION
WALLCOVERING IS PEELING

Acceptable Performance/Condition
Wallcoverings shall not be peeling at the time of the PDI. This condition is warranted only where
a defect in work or material is demonstrated.

Warranty
One-Year – Work and Materials
• Damage caused by dampness or condensation due to failure by the homeowner to maintain
  adequate ventilation is excluded from the statutory warranty.
• Additions, deletions or alterations by the homeowner are not covered by the statutory warranty.

Action
Wallcoverings not meeting the acceptable condition shall be repaired.

Remarks
High humidity levels can create conditions that can cause wallcoverings to peel. Ventilation
of rooms and spaces can help control indoor humidity.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   166
Wall and Ceiling Finish



 9.13

 CONDITION
 PATTERNS IN WALLCOVERING ARE MISMATCHED AT THE EDGES

 Acceptable Performance/Condition
 Wallcoverings shall be installed to achieve a generally uniform appearance when viewed under
 normal lighting conditions and from a normal viewing position, within the manufacturer’s tolerances.

 Warranty
 One-Year – Work and Materials
 • Additions, deletions or alterations by the homeowner are not covered by the statutory warranty.

 Action
 Wallcoverings not meeting the acceptable condition shall be repaired.

 Remarks
 Some wallcoverings are more difficult to match than others due to pattern, colour and texture.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
167   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Wall and Ceiling Finish



9.14

CONDITION
WATER PENETRATION BEHIND CERAMIC TILE AND BATHTUB OR SHOWER ENCLOSURES

Acceptable Performance/Condition
Joints between ceramic tiles and adjacent surfaces shall prevent water penetration.

Warranty
One-Year – Work and Materials
• Damage resulting from improper maintenance and normal wear and tear is excluded from
  the statutory warranty.

Action
Ceramic tile installation not meeting the acceptable performance shall be repaired.

Remarks
The owner must regularly inspect and maintain the “soft caulked joints” between the ceramic
tiles and adjacent surfaces. Grout joints between individual ceramic tiles may deteriorate over
time under normal use; periodic maintenance is required.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   168
Wall and Ceiling Finish



 9.15

 CONDITION
 MILDEW OR FUNGUS IS VISIBLE ON INTERIOR SURFACES

 Acceptable Performance/Condition
 Interior surfaces shall be free of visible mildew and fungus at the time of the PDI.
 This condition is warranted where there is a demonstrated Ontario Building Code violation
 or defect in work or material supplied by the builder.

 Warranty
 One-Year – Work and Materials
 Two-Year – Ontario Building Code Health & Safety Violations
 • Mildew and fungus resulting from improper maintenance and normal wear and tear
   are excluded from the statutory warranty.

 Action
 Interior surfaces not meeting the acceptable condition shall be repaired.

 Remarks
 Note any concerns about visible mildew or fungus on the PDI Form to avoid any dispute about
 whether the condition was caused by improper maintenance or normal wear and tear.
 Mildew and fungus often occur when indoor humidity levels are high. Ventilation of rooms
 and spaces can help control indoor humidity.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
169   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Finishing



10.1

CONDITION
INTERIOR DOOR IS WARPED

Acceptable Performance/Condition
Interior doors leading to rooms or spaces shall not permanently warp more than 6 mm
beyond the edge of the doorjamb when the door is closed.
In the case of double doors, one leaf shall not permanently warp more than 6 mm beyond
the face of the adjacent door leaf.

Warranty
One-Year – Work and Materials
• Damage caused by normal shrinkage of materials due to drying after construction is
  excluded from the statutory warranty.

Action
Doors not meeting the acceptable condition shall be repaired.

Remarks
Minor warping is normal. Interior wood doors are a natural product and are affected by
changes in indoor relative humidity, which may contribute to the warping of the door.
Normal home maintenance includes controlling indoor humidity levels to prevent
permanent warping.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   170
Interior Finishing



 10.2

 CONDITION
 BI-FOLD AND SLIDING DOORS COME OFF TRACKS

 Acceptable Performance/Condition
 Bi-fold and sliding doors shall operate freely and remain on their tracks during normal operation.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from normal wear and tear or improper maintenance is excluded from the
   statutory warranty.

 Action
 Doors not meeting the acceptable performance shall be repaired.

 Remarks
 Confirm proper operation of the doors during the PDI. Defects discovered after the PDI will be
 covered under the warranty if they result from the builder’s work. However, bi-fold and sliding doors
 may require adjustment from time to time to maintain alignment and hardware may need to be
 cleaned and lubricated as part of normal home maintenance.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
171   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Finishing



10.3

CONDITION
POCKET DOOR RUBS

Acceptable Performance/Condition
The face of a pocket door shall not rub against the surrounding framing, doorjamb or casing
during normal operation.

Warranty
One-Year – Work and Materials
• Damage resulting from normal wear and tear and improper maintenance is excluded from
  the statutory warranty.

Action
Doors not meeting the acceptable performance shall be repaired.

Remarks
Confirm proper operation of interior doors during the PDI. Defects discovered after the PDI will be
covered under the statutory warranty if they result from the builder’s work. Some pocket doors
require the use of guides that are designed to rub across the face of the door during normal
operation and may mark the door; this is acceptable.
Pocket doors may require adjustment from time to time and hardware may need to be cleaned
and lubricated.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   172
Interior Finishing



 10.4

 CONDITION
 DOOR RUBS ON THE DOORJAMB OR DOES NOT LATCH

 Acceptable Performance/Condition
 Doors shall operate without rubbing on the doorjamb and latches shall engage with relative ease.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from normal wear and tear and improper maintenance is excluded from the
   statutory warranty.

 Action
 Doors and latches not meeting the acceptable performance shall be repaired.

 Remarks
 Confirm proper operation of the doors during the PDI. Defects discovered after the PDI will be
 covered under the statutory warranty if they result from the builder’s work. Slight pressure may be
 required to engage the latch. Seasonal humidity levels may cause doors and jambs to swell,
 resulting in temporary rubbing; this is acceptable.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
173   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Finishing



10.5

CONDITION
WOOD DOOR PANEL HAS SPLIT

Acceptable Performance/Condition
Cracks, where normal light is visible through the door, are not acceptable. Minor cracks that
do not allow light through the door are acceptable.

Warranty
One-Year – Work and Materials
• Damage resulting from normal shrinkage due to drying after construction is excluded from the
  statutory warranty.

Action
Door panels not meeting the acceptable performance shall be repaired.

Remarks
None.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   174
Interior Finishing



 10.6

 CONDITION
 DOOR DRAGS ON THE FLOOR

 Acceptable Performance/Condition
 Doors shall not contact the floor unless the door is specifically designed to do so.

 Warranty
 One-Year – Work and Materials
 • Defects in materials, design and work supplied by the homeowner are excluded from the
   statutory warranty.

 Action
 Doors not meeting the acceptable performance shall be repaired.

 Remarks
 Confirm proper operation of the doors during the PDI. Defects discovered after the PDI will be
 covered under the warranty if they result from the builder’s work. Interior doors are typically
 undercut to facilitate air movement through the house. See section 8.9 “Inadequate Heating” for
 space under interior doors.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
175   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Finishing



10.7

CONDITION
GAP BETWEEN THE DOOR AND THE DOORJAMB IS NOT UNIFORM

Acceptable Performance/Condition
The width of the gap may vary on different sides or edges of the door.
On any specific side or edge of the door, the door and jamb shall be in general visual alignment;
variance in the gap shall not exceed double the narrowest dimension along that side or edge.

Warranty
One-Year – Work and Materials
• Damage resulting from normal shrinkage of materials due to drying after construction is
  excluded from the statutory warranty.

Action
Doors not meeting the acceptable performance shall be repaired.

Remarks
None.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   176
Interior Finishing



 10.8

 CONDITION
 INTERIOR DOOR SWINGS OPEN OR CLOSES BY ITSELF

 Acceptable Performance/Condition
 Interior doors shall be installed sufficiently plumb and square so they do not swing by themselves
 due to the force of gravity alone.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from alterations, deletions or additions by the homeowner is excluded from the
   statutory warranty.

 Action
 Doors not meeting the acceptable performance shall be repaired.

 Remarks
 Confirm proper operation of interior doors during the PDI. Defects discovered after the PDI will be
 covered under the warranty if they result from the builder’s work. Doors will swing open or
 closed by the force of gravity if the hinges are not aligned plumb.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
177   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Finishing



10.9

CONDITION
DOORS BIND FROM IMPROPERLY INSTALLED HINGES

Acceptable Performance/Condition
Doors shall not bind on their hinges.

Warranty
One-Year – Work and Materials

Action
Doors not meeting the acceptable performance shall be repaired.

Remarks
Confirm proper operation of the doors during the PDI. Defects discovered after the PDI will be
covered under the warranty if they result from the builder’s work. Hinges that are not aligned or are
excessively recessed into the jamb or door may cause the door to bind; this is not acceptable.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   178
Interior Finishing



 10.10

 CONDITION
 HINGES ARE PAINTED

 Acceptable Performance/Condition
 Unless specified in the Agreement of Purchase and Sale or contract, hinges may be painted.
 Paint shall not interfere with the proper operation of the hinges.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from alterations, deletions or additions by the homeowner is excluded from the
   statutory warranty.

 Action
 Hinges not meeting the acceptable performance shall be repaired.

 Remarks
 It is common to paint hinges the same colour as the doorjamb.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
179   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Finishing



10.11

CONDITION
GAPS EXIST BETWEEN STAIR PARTS

Acceptable Performance/Condition
Stair parts (risers, treads, and stringers), where exposed to view in finished areas, shall be
fitted to minimize gaps, having aligned surfaces or be filled with a compatible material to achieve
the same result.

Warranty
One-Year – Work and Materials
• Damage caused by normal shrinkage of materials due to drying after construction is excluded
  from the statutory warranty.

Action
Stairs not meeting the acceptable condition shall be repaired.

Remarks
Stair parts do not include applied trim and moulding. See section 10.15 “Joint Quality of Interior
Trim and Moulding Work”.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   180
Interior Finishing



 10.12

 CONDITION
 SQUEAKING STAIR RISER OR TREAD

 Acceptable Performance/Condition
 Stair risers and treads shall be free of squeaks caused by loose/inadequately fastened joints.

 Warranty
 One-Year – Work and Materials
 • Squeaks caused by normal shrinkage of materials due to drying after construction, improper
   maintenance or normal wear and tear to the stair are excluded from the statutory warranty.

 Action
 Loose/inadequately fastened risers and treads shall be repaired.

 Remarks
 Extended low-humidity indoor environments can cause excessive shrinkage in the wood resulting
 in loose stair connections. The homeowner must maintain indoor humidity levels to prevent
 excessive drying of materials. A squeak-free stair may not be attainable.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
181   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Finishing



10.13

CONDITION
GAPS EXIST BETWEEN RAILING PARTS

Acceptable Performance/Condition
Railing parts shall be fitted to minimize gaps; structural integrity of the joint shall not be affected
by minor gaps.

Warranty
One-Year – Work and Materials
• Gaps resulting from normal shrinkage of materials due to drying after construction are excluded
  from the statutory warranty.

Action
Railings not meeting the acceptable condition shall be repaired.

Remarks
Minor gaps may exist due to different methods of fabrication of the railing.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   182
Interior Finishing



 10.14

 CONDITION
 STAIR RAILINGS LACK RIGIDITY

 Acceptable Performance/Condition
 Stair railings shall be securely constructed in accordance with the Ontario Building Code.

 Warranty
 One-Year – Work and Materials
 Two-Year – Ontario Building Code Health & Safety Violations

 Action
 Stair railings not meeting the acceptable condition shall be repaired.

 Remarks
 Even when installed in accordance with the Ontario Building Code, slight movement in stair
 railings may occur under normal use and is acceptable.
 The selection of materials and the design of the stair railing can affect rigidity.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
183   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Finishing



10.15

CONDITION
JOINT QUALITY OF INTERIOR TRIM AND MOULDING WORK

Acceptable Performance/Condition
Joints in trim, where exposed to view, shall be tightly fitted and have aligned surfaces or be
filled with a compatible material to achieve the same result; cracks in excess of 1.5 mm are
not acceptable.

Warranty
One-Year – Work and Materials
• Minor gaps caused by normal shrinkage of materials due to drying after construction are
  excluded from the statutory warranty.

Action
Joints not meeting the acceptable condition shall be repaired.

Remarks
None.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   184
Interior Finishing



 10.16

 CONDITION
 NAILHEADS AND FASTENERS ARE NOT PROPERLY SET OR FILLED

 Acceptable Performance/Condition
 Nailheads and fasteners shall not protrude above the surface. Where nailheads and fasteners
 have been set below the surface they shall be filled with compatible filler unless designed
 otherwise. Filler may be noticeable under normal lighting conditions.

 Warranty
 One-Year – Work and Materials

 Action
 Nailheads and fasteners not meeting the acceptable condition shall be repaired.

 Remarks
 This does not apply in unfinished rooms or spaces.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
185   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Finishing



10.17

CONDITION
INTERIOR TRIM IS SPLIT

Acceptable Performance/Condition
Trim shall not have visible splits.

Warranty
One-Year – Work and Materials
• Damage caused by normal shrinkage of materials due to drying after construction is excluded
  from the statutory warranty.

Action
Trim not meeting the acceptable condition shall be repaired.

Remarks
Filler may be used to repair splits.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   186
Interior Finishing



 10.18

 CONDITION
 HAMMER MARKS ARE VISIBLE ON TRIM

 Acceptable Performance/Condition
 Interior finished trim shall be free from visible hammer marks at the time of the PDI.

 Warranty
 One-Year – Work and Materials

 Action
 Trim not meeting the acceptable condition shall be repaired.

 Remarks
 Damaged interior finished trim not identified on the PDI Form may be excluded from the statutory
 warranty, unless the homeowner is able to establish that the damage was caused by the builder.
 Repaired areas shall match the original finished surface for colour, sheen and texture as closely
 as possible.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
187   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Interior Finishing



10.19

CONDITION
RESIN BLEEDING THROUGH PAINTED FINISH

Acceptable Performance/Condition
Resin shall not bleed through painted finish on trim.

Warranty
One-Year – Work and Materials

Action
Painted finishes not meeting the acceptable condition shall be repaired.

Remarks
The extent of resin bleeding, while a natural characteristic of wood, can be controlled.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   188
Interior Finishing



 10.20

 CONDITION
 WALL AREA AROUND COLD ROOM DOOR IS UNFINISHED

 Acceptable Performance/Condition
 Where the cold room is located in an unfinished basement, wall finish around the door is not
 required.

 Warranty
 One-Year – Work and Materials
 Two-Year – Ontario Building Code Health & Safety Violations
 • Damage resulting from alterations, deletions or additions made by the homeowner is excluded
   from the statutory warranty.

 Action
 Where the wall finish is not installed, no action is required.

 Remarks
 The door frame must be secured to operate properly and be installed to meet the Ontario Building
 Code requirements for insulation, air and vapour barriers and weatherstripping.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
189   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Cabinets and Countertops



11.1

CONDITION
GAP BETWEEN CABINETS AND CEILINGS OR WALLS

Acceptable Performance/Condition
Cabinets shall be fitted to each other. Where cabinets abut walls and ceilings, visible gaps in
excess of 3 mm are not acceptable.

Warranty
One-Year – Work and Materials
• Damage resulting from normal shrinkage of materials due to drying after construction is
  excluded from the statutory warranty.

Action
Cabinets not meeting the acceptable condition shall be repaired.

Remarks
It is common to have gaps where cabinets meet different materials.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   190
Cabinets and Countertops



 11.2

 CONDITION
 CABINETS DO NOT LINE UP WITH EACH OTHER

 Acceptable Performance/Condition
 Cabinets shall be aligned with adjacent cabinets and filler panels on the same level to provide
 a generally uniform appearance when viewed from a normal viewing position.

 Warranty
 One-Year – Work and Materials
 • Damage due to normal wear and tear is excluded from the statutory warranty.

 Action
 Cabinets not meeting the acceptable condition shall be repaired.

 Remarks
 Cabinet doors can become misaligned through normal use; normal home maintenance includes
 adjusting the cabinet doors from time to time.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
191   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Cabinets and Countertops



11.3

CONDITION
CABINET DOORS AND DRAWER FACES ARE WARPED

Acceptable Performance/Condition
Cabinet doors and drawer faces shall not permanently warp.

Warranty
One-Year – Work and Materials

Action
Cabinet doors and drawer faces not meeting the acceptable condition shall be repaired.

Remarks
Humidity levels in the home affect cabinet doors and drawer faces made from natural wood
products. Some movement can be expected.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   192
Cabinets and Countertops



 11.4

 CONDITION
 CABINET DOOR OR DRAWER BINDS OR RUBS

 Acceptable Performance/Condition
 Cabinet doors and drawers shall be installed so they don’t bind or rub under normal use.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from normal wear and tear or improper maintenance is excluded from the
   statutory warranty.

 Action
 Doors and drawers not meeting the acceptable condition shall be repaired.

 Remarks
 Cabinet doors and drawers can become misaligned through normal use; normal home
 maintenance includes adjusting the cabinet doors and drawers from time to time.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
193   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Cabinets and Countertops



11.5

CONDITION
CABINET DOORS WILL NOT STAY CLOSED

Acceptable Performance/Condition
Doors shall stay in position when closed.

Warranty
One-Year – Work and Materials
• Damage resulting from normal wear and tear or improper maintenance is excluded from the
  statutory warranty.

Action
Doors not meeting the acceptable condition shall be repaired.

Remarks
Cabinet doors can become misaligned through normal use; normal home maintenance includes
adjusting the cabinet doors from time to time.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   194
Cabinets and Countertops



 11.6

 CONDITION
 LAMINATED COUNTERTOP HAS SWELLED

 Acceptable Performance/Condition
 Laminated countertops shall not have localized bumps or swells at the time of the PDI.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance is excluded from the statutory warranty.

 Action
 Countertops not meeting the acceptable condition shall be repaired.

 Remarks
 Damaged countertops not identified on the PDI Form may be excluded from the statutory warranty,
 unless the homeowner is able to establish that the damage was caused by the builder. Countertops
 are susceptible to damage from standing water. Care must be taken to ensure that countertops are
 kept free of standing water at joints and openings at sinks and faucets.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
195   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Cabinets and Countertops



11.7

CONDITION
LAMINATED COUNTERTOP IS DELAMINATED

Acceptable Performance/Condition
The surface of laminated countertops shall not delaminate.

Warranty
One-Year – Work and Materials
• Damage resulting from normal wear and tear and improper maintenance is excluded from
  the statutory warranty.

Action
Countertops not meeting the acceptable condition shall be repaired.

Remarks
Delamination can be caused by excessive heat from appliances and cooking equipment.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   196
Cabinets and Countertops



 11.8

 CONDITION
 CRACKS IN COUNTERTOP SURFACES

 Acceptable Performance/Condition
 Countertop surfaces exposed to view shall be free from cracks at the time of the PDI.
 Joints are not considered to be cracks.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from normal wear and tear is excluded from the statutory warranty.

 Action
 Countertops not meeting the acceptable condition shall be repaired.

 Remarks
 Damaged countertops not identified on the PDI Form may be excluded from the statutory warranty,
 unless the homeowner is able to establish that the damage was caused by the builder.
 Manufactured solid-surface countertops can be brittle and damaged by impact. Care should be
 taken when cleaning or servicing to prevent cracking or chipping. Sitting or dropping heavy objects
 on the countertop can create excessive loads that can cause cracking.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
197   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Cabinets and Countertops



11.9

CONDITION
SCRATCHES/CHIPS ON COUNTERTOPS

Acceptable Performance/Condition
Countertop surfaces exposed to view shall be free from visible damage at the time of the PDI.

Warranty
One-Year – Work and Materials
• Damage resulting from normal wear and tear is excluded from the statutory warranty.

Action
Visible damage shall be repaired.

Remarks
Damaged countertops not identified on the PDI Form may be excluded from the statutory warranty,
unless the homeowner is able to establish that the damage was caused by the builder. Maintain
countertop surfaces in accordance with the manufacturer’s instructions.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   198
Flooring



 12.1

 CONDITION
 TRANSITION BETWEEN DIFFERENT TYPES OF FLOORING IS NOT FLUSH

 Acceptable Performance/Condition
 An abrupt change in height where different floor finishes abut is acceptable provided the
 transition is suitably eased (see Remarks).

 Warranty
 One-Year – Work and Materials

 Action
 Where the acceptable performance has not been met, repairs shall be made.

 Remarks
 The subfloor provides the even base on which all finished flooring materials are installed.
 Changes in height between different flooring materials are caused by material thickness
 and/or installation methods.
 Standard practice (unless discussed prior to construction and specified in the Agreement
 of Purchase and Sale or contract) is to install a transition strip of a material such as wood,
 metal or marble to ease the change in height. These transition strips do not constitute a tripping
 hazard and may be used at the builder’s discretion. Transition strips may vary in material,
 colour, grain and/or dimension.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
199   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.2

CONDITION
FLOOR IS UNEVEN

Acceptable Performance/Condition
Applied finished flooring shall be installed without visible ridges or depressions. Where visible
ridges or depressions occur, the variation from the specified plane shall not exceed ±6 mm.

Warranty
One-Year – Work and Materials
• Ridges and depressions caused by normal shrinkage of materials are excluded from
  the statutory warranty.

Action
Visible ridges or depressions exceeding the acceptable condition shall be repaired.

Remarks
The homeowner must maintain finished flooring in accordance with manufacturer’s
recommendations and prevent the accumulation of water on flooring.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   200
Flooring



 12.3

 CONDITION
 PATTERN OF FINISHED FLOORING IS OUT OF ALIGNMENT WITH ADJACENT
 WALL SURFACES

 Acceptable Performance/Condition
 Finished flooring shall be installed in general visual alignment with adjacent wall surfaces.
 Variation greater than 12.5 mm in 1,800 mm is not acceptable when visible in a room used
 for its intended purpose.

 Warranty
 One-Year – Work and Materials

 Action
 Finished flooring not meeting the acceptable condition shall be repaired.

 Remarks
 This does not apply to angled or curved walls or flooring not designed to be aligned. The method
 of repair will vary with the type of finished flooring installed.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
201   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.4

CONDITION
CARPET SEAM IS VISIBLE

Acceptable Performance/Condition
Carpet seams shall be installed with the backing tightly fitted in accordance with the
manufacturer’s specifications.

Warranty
One-Year – Work and Materials
• Damaged carpet seams resulting from normal wear and tear or improper maintenance
  are excluded from the statutory warranty.

Action
Carpet seams not meeting the acceptable condition shall be repaired.

Remarks
Identify any concerns about visible carpet seams on the PDI Form to avoid any suggestion that
the problem is one of normal wear and tear. Visibility of carpet seams will vary with type
of carpet and varying lighting conditions. Although the backing may be tightly fitted, a seam
may remain visible; this is acceptable. Where carpets must be cut to execute floor repairs, seams
in the repair area may be more visible. Location of carpet seams may vary due to predetermined
manufactured widths and installation restrictions and are discretionary. Seams around pickets
and end caps on stairs are often visible.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   202
Flooring



 12.5

 CONDITION
 CARPET IS LOOSE OR STRETCHING HAS OCCURRED

 Acceptable Performance/Condition
 Carpeting shall be installed in accordance with the manufacturer’s specifications to prevent
 loosening at edges, separation from its point of attachment and to minimize stretching under
 normal use.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance, normal wear and tear, or dampness or
   condensation due to failure of the homeowner to maintain adequate ventilation is excluded
   from the statutory warranty.

 Action
 Carpet not meeting the acceptable condition shall be repaired.

 Remarks
 Carpets should be maintained in accordance with manufacturer’s recommendations. The use
 of inappropriate cleaning equipment can damage carpet material.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
203   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.6

CONDITION
SPOTS OR FADING ON CARPET

Acceptable Performance/Condition
Carpet shall be free from spots and faded areas.

Warranty
One-Year – Work and Materials
• Spots or faded areas in carpet resulting from normal wear and tear or improper maintenance
  are excluded from the statutory warranty.

Action
Spotted or faded carpet recorded on the PDI Form will be repaired. If not noted on the PDI Form,
the homeowner must establish that the damage was caused by the builder.

Remarks
Identify any damaged carpeting at the PDI to avoid any dispute about whether the damage was
caused by the builder. Repaired area may be visible as a result of variable lighting conditions or
different material dye lot.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   204
Flooring



 12.7

 CONDITION
 CARPET NOT UNIFORM IN COLOUR

 Acceptable Performance/Condition
 Within a room or defined area, carpet shall be uniform in colour, texture and pattern when viewed
 under normal lighting conditions. Carpet pieces in the same room or defined area shall be installed
 with the pile oriented in the same direction. Minor variation between dye lots is acceptable.

 Warranty
 One-Year – Work and Materials

 Action
 Carpet not meeting the acceptable condition shall be repaired.

 Remarks
 Slight variation in colour may occur due to different lighting effects and at transitions between rooms
 or areas. Doorways and thresholds are acceptable locations where pile direction may change.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
205   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.8

CONDITION
CARPET HAS DARK STAINS AROUND PERIMETER OF ROOMS AND AT HEATING REGISTERS

Acceptable Performance/Condition
Dark stains on carpet around room perimeters and at heating registers, commonly called “carbon
black”, are an occupant use and house location issue. Sources of carbon rarely relate to work and
material supplied by the builder.

Warranty
None.
• Stains resulting from normal wear and tear or improper maintenance are excluded from the
  statutory warranty.

Action
The homeowner shall ensure that furnaces, fireplaces, and other combustion appliances within
the home are not leaking products of combustion.

Remarks
Dark staining often results from airborne carbon material settling out on synthetic or magnetic
surfaces such as televisions screens, carpets and magnetic seals on refrigerators. Burning scented
candles contributes to carpet staining. Light-coloured synthetic carpets accentuate this condition.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   206
Flooring



 12.9

 CONDITION
 HOLLOW AREAS IN UNDERPAD BELOW CARPET SURFACE

 Acceptable Performance/Condition
 Carpet underpad shall provide a continuous surface of support for the carpet.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from normal wear and tear, such as furniture loads that may cause local
   depressions, is excluded from the statutory warranty.

 Action
 Hollow areas in underpad shall be repaired.

 Remarks
 Carpet underpad is often omitted at the base of stair pickets and nosings.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
207   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.10

CONDITION
PROTRUSIONS APPEAR ON THE SURFACE OF RESILIENT FLOORING
WITHOUT BREAKING THROUGH

Acceptable Performance/Condition
Finished surface of flooring shall be free of visible protrusions (bumps, fasteners, telegraphing) that
deform the surface of the flooring when viewed under normal lighting conditions (not reflected light)
from a normal standing position.

Warranty
One-Year – Work and Materials

Action
Visible protrusions in the flooring shall be repaired.

Remarks
Reflected light, particularly from large windows, exaggerates any irregularity in the floors and
should not be considered normal lighting.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   208
Flooring



 12.11

 CONDITION
 RESILIENT SHEET FLOORING IS LOOSE

 Acceptable Performance/Condition
 Resilient sheet flooring shall not come unglued from the substrate.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance is excluded from the statutory warranty.

 Action
 Flooring not meeting the acceptable condition shall be repaired.

 Remarks
 The homeowner must maintain the flooring in accordance with the manufacturer’s instructions.
 Excessive water or heat can adversely affect the glue joint.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
209   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.12

CONDITION
RESILIENT FLOORING JOINTS NOT TIGHT

Acceptable Performance/Condition
Resilient flooring shall be installed with no visible gaps in the joints when viewed under normal
lighting conditions in a standing position.

Warranty
One-Year – Work and Materials
• Gaps in joints resulting from inappropriate use or maintenance procedures cannot be considered
  for the statutory warranty.

Action
Visible gaps not meeting the acceptable condition shall be repaired in accordance with the
manufacturer’s specifications.

Remarks
The visibility of gaps is dependent on a number of factors including texture, pattern, colour, type
of resilient material, and lighting. Reflected light, particularly from large windows, exaggerates
any irregularity in the floors and should not be considered normal lighting.
Joint filler recommended by the flooring manufacturer may be used to fill gaps between seams
of sheet flooring.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   210
Flooring



 12.13

 CONDITION
 BUBBLES APPEAR ON VINYL FLOORING SURFACE

 Acceptable Performance/Condition
 Vinyl flooring shall be free from bubbles that cause surface deformities visible from a normal
 viewing position, under normal lighting conditions without magnification by reflected light.

 Warranty
 One-Year – Work and Materials
 • Bubbles caused by normal wear and tear or improper maintenance are excluded from the
   statutory warranty.

 Action
 Vinyl flooring not meeting the acceptable condition shall be repaired.

 Remarks
 As part of repair procedures, vinyl material may be punctured to remove the trapped air.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
211   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.14

CONDITION
PATTERNS ON SHEET VINYL FLOORING ARE NOT ALIGNED ACROSS SEAMS

Acceptable Performance/Condition
Flooring shall be installed to achieve pattern alignment within the manufacturer’s tolerance.

Warranty
One-Year – Work and Materials

Action
Flooring not meeting the acceptable condition shall be repaired.

Remarks
Manufacturer’s tolerances for alignment may vary with patterns, textures and colour of material.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   212
Flooring



 12.15

 CONDITION
 RESILIENT (FLEXIBLE) FLOOR TILE IS LOOSE

 Acceptable Performance/Condition
 Resilient floor tiles shall be securely bonded to the substrate.

 Warranty
 One-Year – Work and Materials
 • Tiles that become detached as a result of improper maintenance, physical damage or
   moisture, normal wear and tear and chemical contamination cannot be considered for the
   statutory warranty.

 Action
 Only warranted floor tiles that become loose shall be repaired.

 Remarks
 The homeowner must maintain tiles in accordance with manufacturer’s written instructions.
 Shade variations within specified colours in replacement tiles are acceptable.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
213   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.16

CONDITION
PATTERNS OR CORNERS OF RESILIENT FLOOR TILE ARE MISALIGNED

Acceptable Performance/Condition
Resilient floor tiles shall be installed with tight joints to provide a generally uniform appearance
throughout the room or defined area when viewed under normal lighting conditions from a normal
viewing position.

Warranty
One-Year – Work and Materials

Action
Flooring not meeting the acceptable condition shall be repaired.

Remarks
Alignment of patterns or corners may vary with tile dimensions, shape, texture and colour
of material.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   214
Flooring



 12.17

 CONDITION
 YELLOWING APPEARS ON SURFACE OF VINYL FLOORING

 Acceptable Performance/Condition
 Sheet vinyl flooring shall be installed in accordance with the manufacturer’s specifications.

 Warranty
 One-Year – Work and Materials
 • Yellowing due to improper maintenance or to additions, deletions, or alterations by the
   homeowner is excluded from the statutory warranty.

 Action
 Vinyl flooring not meeting the acceptable condition shall be repaired.

 Remarks
 The use of inappropriate cleaning materials or coverings, such as latex-backed carpets,
 may cause discolouration of the flooring. Direct sunlight naturally causes general yellowing
 over time and is normal.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
215   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.18

CONDITION
DYE LOT VARIATIONS IN VINYL FLOORING

Acceptable Performance/Condition
Within a room or defined area, resilient flooring shall be uniform in colour, texture and pattern
when viewed under normal lighting conditions. Minor variation between dye lots is acceptable.

Warranty
One-Year – Work and Materials

Action
Resilient flooring not meeting the acceptable condition shall be repaired.

Remarks
Slight variation in colour may occur due to different lighting effects and pattern.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   216
Flooring



 12.19

 CONDITION
 VARIATION IN COLOUR OCCURRING DURING REPAIR OF VINYL FLOORING

 Acceptable Performance/Condition
 Shade variations between existing material and repaired areas are acceptable within specified
 colours when viewed from a normal viewing position.

 Warranty
 One-Year – Work and Materials

 Action
 Shade variations greater than the acceptable condition shall be repaired.

 Remarks
 Variation between dye lots within a specified colour or pattern is normal. Spare original material
 may be left in the residence for future repairs at the builder’s discretion. Where a dye lot match is
 unavailable, material may be removed and used for repair from another inconspicuous location.
 Builder’s policies may vary.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
217   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.20

CONDITION
CRACKS DEVELOPING BETWEEN STRIPS OF HARDWOOD OR PARQUET FLOORING

Acceptable Performance/Condition
Cracks resulting from joints that remain open in excess of 2 mm over the length of the strip are
not acceptable.

Warranty
One-Year – Work and Materials
• Cracks resulting from normal shrinkage of materials due to drying after construction, damage
  caused by normal wear and tear or improper maintenance is excluded from the statutory warranty.

Action
Cracks greater than the acceptable condition shall be repaired.

Remarks
Hardwood and parquet flooring are natural wood products and therefore are highly susceptible to
changes in indoor relative humidity, which may cause dimensional changes in the flooring material.
To determine warrantability, the width of the crack should be measured during both the heating
and cooling seasons.
The homeowner has a responsibility to maintain indoor humidity levels through humidification,
ventilation, air conditioning or dehumidification to prevent permanent, irreversible damage.
A hygrometer can be used to monitor indoor humidity levels.
Areas around heat registers and those exposed to concentrated sunlight may be more susceptible.
Wood filler may be used for repairs.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   218
Flooring



 12.21

 CONDITION
 STRIP HARDWOOD FLOORING IS CUPPED (HIGH EDGES)

 Acceptable Performance/Condition
 Strip hardwood flooring shall be installed without cupping.

 Warranty
 One-Year – Work and Materials
 • Damage caused by improper maintenance is excluded from the statutory warranty.
 • Cupping caused by excessive humidity due to failure by the homeowner to maintain adequate
   ventilation is excluded from the statutory warranty.

 Action
 One complete heating and cooling season should be allowed as the problem may remedy itself.
 Cupping identified at the time of the PDI shall be repaired. Cupping that occurs after the PDI and
 is proven to result from defective work or materials shall be repaired.

 Remarks
 Identify any damaged hardwood flooring on the PDI Form to avoid any dispute about whether the
 damage was caused by the builder. Cupping of hardwood strip flooring results from excessive
 moisture when the humidity below the finished flooring material is substantially higher than above.
 The homeowner has a responsibility to maintain indoor humidity levels through humidification,
 ventilation, air conditioning or dehumidification to prevent permanent, irreversible damage.
 A hygrometer can be used to monitor indoor humidity levels.
 The immediate sanding of a cupped floor without first allowing it to correct itself may cause even
 more damage.
 This condition commonly occurs when houses do not have adequate ventilation and can, under
 certain circumstances, result from defects in work or materials.
 See Appendix A2 “Moisture and Wood Floors” for more information.

 Words in italics are defined in the “Terminology” section on pages 15-17.


 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
219   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.22

CONDITION
THE SURFACE OF ONE STRIP OF HARDWOOD OR PARQUET FLOORING
IS HIGHER THAN ANOTHER

Acceptable Performance/Condition
Strip hardwood flooring or parquet flooring shall be installed to provide a surface where adjacent
strips have no more than a 2 mm difference in elevation.

Warranty
One-Year – Work and Materials

Action
Flooring not meeting the acceptable performance shall be repaired.

Remarks
Wood is a natural product and variation in colour and grain pattern from one piece of flooring to
another is normal and may exaggerate the appearance of the condition.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   220
Flooring



 12.23

 CONDITION
 FLOOR FINISH ON WOOD FLOORING IS NOT UNIFORM

 Acceptable Performance/Condition
 Floor finish shall provide a visible uniform surface when viewed without magnification from a
 normal viewing position.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from normal wear and tear is excluded from the statutory warranty.

 Action
 Hardwood flooring surfaces not uniform in appearance shall be repaired.

 Remarks
 Wood is a natural product and variation in colour and grain pattern from one piece of flooring to
 another is normal. The open grain in some wood surfaces tends to show a rough appearance,
 however this is a natural property of wood and is acceptable. Reflected light, particularly from large
 windows, magnifies any irregularity in the floors and should not determine acceptance. This applies
 to both pre-finished and site-applied wood flooring.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
221   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.24

CONDITION
FINISH ON WOOD FLOORING HAS BLISTERED, BUBBLED, OR PEELED RESULTING
IN DETACHMENT OF FINISH

Acceptable Performance/Condition
Site-applied or factory-applied finish on hardwood flooring shall not blister, bubble or peel when
properly maintained and used under normal conditions.

Warranty
One-Year – Work and Materials
• Damage noted on the PDI Form will be repaired. If not noted, the homeowner must establish that
  the damage was caused by the builder. Damage caused by normal wear and tear or improper
  maintenance is excluded from the statutory warranty.

Action
Defective finished surfaces shall be repaired.

Remarks
Identify any damaged hardwood flooring on the PDI Form to avoid any dispute about whether
the damage was caused by the builder. Isolated air bubbles not resulting in detachment of the
finish are acceptable.
Colour variation in the wood may cause the area of repair to be visible under normal lighting
conditions, even when the repair is undertaken in accordance with a manufacturer’s
recommendations. Wood is a natural product and variation in colour and grain pattern from
one piece of flooring to another is normal.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   222
Flooring



 12.25

 CONDITION
 CROWNING OF STRIP HARDWOOD FLOORING HAS OCCURRED (CENTRE OF STRIP
 IS HIGHER THAN EDGES)

 Acceptable Performance/Condition
 Strip hardwood flooring shall be installed without crowning.

 Warranty
 One-Year – Work and Materials
 • Damage caused by improper maintenance and excessive humidity due to failure by the
   homeowner to maintain adequate ventilation is excluded from the statutory warranty.

 Action
 Crowning of hardwood flooring identified on the PDI shall be repaired. If not identified, the
 homeowner must establish that the damage was caused by the builder.

 Remarks
 Identify any damaged hardwood flooring on the PDI Form to avoid any dispute about whether the
 damage was caused by the builder. Crowning of hardwood strip flooring results from the surface
 of the flooring being exposed to excessive moisture. This condition commonly develops when
 houses do not have adequate ventilation or the surface is exposed to water. The homeowner has a
 responsibility to maintain indoor humidity levels through humidification, ventilation, air conditioning
 or dehumidification to prevent permanent, irreversible damage. A hygrometer can be used to
 monitor indoor humidity levels. Never damp mop hardwood flooring.
 See Appendix A2 “Moisture and Wood Floors” for more information.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
223   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.26

CONDITION
WOOD FLOORING BUCKLES AND DETACHES FROM SUBSTRATE

Acceptable Performance/Condition
Hardwood flooring shall be firmly fastened to the substrate in accordance with manufacturer’s
specifications.

Warranty
One-Year – Work and Materials
• Buckling caused by excessive humidity due to failure by the homeowner to maintain adequate
  ventilation or improper maintenance is excluded from the statutory warranty.

Action
Only warranted loose hardwood flooring shall be repaired.

Remarks
The homeowner has a responsibility to maintain indoor humidity levels through humidification,
ventilation, air conditioning or dehumidification to prevent permanent, irreversible damage.
A hygrometer can be used to monitor indoor humidity levels. Wood flooring shall be installed
to accommodate normal expansion and contraction.
See Appendix A2 “Moisture and Wood Floors” for more information.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   224
Flooring



 12.27

 CONDITION
 KNOTS AND COLOUR VARIATION IN STRIP WOOD FLOORING

 Acceptable Performance/Condition
 Knots or colour variation are acceptable within different grades of flooring.

 Warranty
 One-Year – Work and Materials

 Action
 Flooring not meeting the acceptable condition shall be replaced.

 Remarks
 Knots and colour variation are natural characteristics of wood and are acceptable within the
 specified grade.
 The homeowner’s area rugs, latex-backed material or any coverings over floors may result
 in colour variation of the floor. Natural lighting will also cause discolouration.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
225   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.28

CONDITION
SPLINTERS OCCUR IN STRIP WOOD FLOORING

Acceptable Performance/Condition
Finished flooring shall have a surface that is smooth, even and free from splinters.

Warranty
One-Year – Work and Materials
• Splinters resulting from improper maintenance are excluded from the statutory warranty.

Action
Splintered flooring shall be repaired.

Remarks
Splinters should not occur under normal usage conditions.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   226
Flooring



 12.29

 CONDITION
 “STICKER BURN” APPEARS ON SURFACE OF STRIP FLOORING

 Acceptable Performance/Condition
 The surface of strip wood flooring shall be free from discolouration caused by manufacturing
 or storage procedures within the different grade of flooring specified.

 Warranty
 One-Year – Work and Materials

 Action
 Discoloured pieces of flooring shall be repaired or replaced where disallowed by the grade.

 Remarks
 “Sticker burn” is discolouration across the width of the board caused by the sticks used between the
 lumber during the drying process. Sticker burn is acceptable within some different specified grades.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
227   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.30

CONDITION
CERAMIC/PORCELAIN TILE, MARBLE OR STONE FLOORING IS BROKEN OR LOOSE
(INCLUDING MARBLE TRANSITIONS)

Acceptable Performance/Condition
Ceramic/porcelain tile, marble or stone flooring shall be installed to prevent it from cracking or
coming loose from the substrate.
In rooms or areas where the flooring must provide a degree of water resistance required by the
Ontario Building Code, cracked or loose flooring allowing water to penetrate is not acceptable.

Warranty
One-Year – Work and Materials
• Where floors are not required to provide water resistance, cracked or loose tiles resulting
  from normal shrinkage of materials due to drying after construction are excluded from the
  statutory warranty.
• Damage caused by normal wear and tear or improper maintenance is excluded from the
  statutory warranty.

Action
Flooring not meeting the acceptable condition shall be repaired.

Remarks
Identify any damaged ceramic/porcelain tile on the PDI Form to avoid any dispute about whether
the damage was caused by the builder. Variations between dye lots of similar materials within a
specified colour or pattern are normal and acceptable provided they are not readily visible.
Slight variations in grout colour are to be expected when making repairs.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   228
Flooring



 12.31

 CONDITION
 CRACKS APPEARING IN GROUTING OF CERAMIC TILE JOINTS OR AT JUNCTIONS WITH
 OTHER MATERIALS SUCH AS BATHTUBS

 Acceptable Performance/Condition
 Hairline cracks in grout are common, however, loose or missing grout is unacceptable.

 Warranty
 One-Year – Work and Materials
 • Cracks resulting from normal shrinkage of materials due to drying after construction are
   excluded from the statutory warranty.

 Action
 Cracks not meeting the acceptable condition shall be repaired.

 Remarks
 Slight variations in grout colour are to be expected when making repairs.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
229   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Flooring



12.32

CONDITION
ADJACENT MARBLE UNITS OR CERAMIC TILE SURFACES INSTALLED
AT DIFFERENT ELEVATIONS

Acceptable Performance/Condition
Adjacent marble units and/or adjacent ceramic tiles shall be installed generally flush, taking into
account the texture and intended aesthetic application of the finished surface.

Warranty
One-Year – Work and Materials

Action
Tile installations not meeting the acceptable performance shall be repaired.

Remarks
Some floor tiles are designed with irregular finished surfaces, which may exaggerate the aesthetic
appearance of the condition.
Variations in grout and tile colour are to be expected when making repairs.
Variation between dye lots of similar materials within a specified colour or pattern is normal.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   230
Flooring



 12.33

 CONDITION
 GROUT IS NOT A UNIFORM COLOUR

 Acceptable Performance/Condition
 In a room or defined area the colour of grouted joints between ceramic tiles shall appear
 generally uniform under normal lighting conditions and from a normal viewing position.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance and normal wear and tear is excluded from
   the statutory warranty.

 Action
 Grout joints not meeting the acceptable condition shall be repaired.

 Remarks
 Minor variation in grout joint colour is normal.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
231   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Chimneys and Fireplaces



13.1

CONDITION
JOINT OR CRACK IN CHIMNEY CAP ALLOWS WATER LEAK

Acceptable Performance/Condition
Chimney caps shall be waterproof.

Warranty
Two-Year – Building Envelope Water Penetration

Action
Chimney caps not meeting the acceptable performance shall be repaired.

Remarks
Masonry chimney cap cracks may develop due to the severe conditions caps must endure.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   232
Chimneys and Fireplaces



 13.2

 CONDITION
 ROOF FLASHING LEAKS AT CHIMNEY

 Acceptable Performance/Condition
 Roof flashings at chimneys shall not leak under normal weather conditions.

 Warranty
 Two-Year – Building Envelope Water Penetration
 • Damage resulting from improper maintenance is not covered by the statutory warranty.

 Action
 Roof flashings not meeting the acceptable performance shall be repaired.

 Remarks
 Ice buildup around chimneys can contribute to water penetration. Keeping roofs clear of heavy
 snow and ice is important to help prevent ice buildup. Normal home maintenance should
 include professional removal of heavy buildups of ice and snow.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
233   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Chimneys and Fireplaces



13.3

CONDITION
BRICKS BREAKING UP ON SURFACE OF CHIMNEY

Acceptable Performance/Condition
Bricks used for chimneys shall not deteriorate or become displaced.

Warranty
One-Year – Work and Materials
Two-Year – Cladding Detachment, Displacement or Deterioration

Action
Bricks not meeting the acceptable performance shall be repaired.

Remarks
Moisture migration into the chimney brick can contribute to premature deterioration.
Chimney cap overhangs are critical to protect the chimney from weather.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   234
Chimneys and Fireplaces



 13.4

 CONDITION
 CHIMNEY SERVING SOLID-FUEL-BURNING (WOOD, PELLET, ETC.) APPLIANCE
 DOES NOT DRAW PROPERLY

 Acceptable Performance/Condition
 Chimneys serving solid-fuel-burning appliances shall be installed in accordance with the
 Ontario Building Code.

 Warranty
 One-Year – Work and Materials
 Two-Year – Ontario Building Code Health & Safety Violations
 • Damage resulting from improper maintenance or additions, deletions or alterations made
   by a homeowner is excluded from the statutory warranty.

 Action
 Chimneys not meeting the acceptable performance shall be repaired.

 Remarks
 Chimneys may not draw properly if:
 • adjacent buildings, trees or high winds create downdrafts
 • the chimney is plugged
 • the chimney is cold
 • the combustion air supply for the appliance is restricted.
 Opening a window may help the chimney draw properly. Inspecting and cleaning the chimney
 is part of regular home maintenance.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
235   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Chimneys and Fireplaces



13.5

CONDITION
FIREPLACE FIREBOX PAINT COLOUR CHANGED

Acceptable Performance/Condition
Fireplace firebox paint colour may change with time and use.

Warranty
None.

Action
None.

Remarks
Even though the firebox paint is designed for high temperatures, the paint may change colour.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   236
Chimneys and Fireplaces



 13.6

 CONDITION
 FIREBRICK IS BROKEN

 Acceptable Performance/Condition
 Firebrick shall not break during the statutory warranty period. This condition is warranted
 only where a defect in work or material is demonstrated.

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance or normal wear and tear is not covered
   by the statutory warranty.

 Action
 Firebricks not meeting the acceptable performance shall be repaired.

 Remarks
 Firebrick provides the primary heat protection in the firebox. Overheating can cause
 premature cracking. Firebricks can be damaged by impact.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
237   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.1

CONDITION
GARAGE FLOOR HAS HEAVED OR SETTLED

Acceptable Performance/Condition
Non-structural poured concrete garage floors supported by grade shall not heave or settle
to produce a negative slope into the garage.

Warranty
One-Year – Work and Materials

Action
Repair slab to provide drainage in accordance with the Ontario Building Code.

Remarks
Repair may involve modifications to either the garage floor or supporting sub-grade.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   238
Garages and Exterior



 14.2

 CONDITION
 CONCRETE GARAGE FLOOR IS CRACKED

 Acceptable Performance/Condition
 Cracks resulting from normal shrinkage are acceptable; crack width in excess of 6 mm
 is not acceptable.

 Warranty
 One-Year – Work and Materials
 • Cracks resulting from normal shrinkage of materials caused by drying after construction
   are excluded from the statutory warranty.

 Action
 Cracks in excess of the acceptable condition shall be repaired.

 Remarks
 Concrete floors naturally crack during curing due to shrinkage. Actual crack width shall be
 determined using a wire feeler gauge* inserted inside the crack. Where repairs are necessary,
 colour and/or texture of repair materials may not match the surrounding concrete.

 * Because it is of a manufactured, set size, an Allen Wrench/Key may be used as a wire feeler gauge.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
239   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.3

CONDITION
NO REINFORCING IN GARAGE SLAB

Acceptable Performance/Condition
Unless the slab is specifically intended and designed to be a structural slab, reinforcing
or mesh is not required.

Warranty
One-Year – Work and Materials
Seven-Year – Major Structural Defect

Action
Where a structural slab is not reinforced as required by the design, repairs shall be made;
otherwise no action is required.

Remarks
Concrete slabs in garages shall conform to Section 9.16 of the Ontario Building Code.
Reinforcing of concrete slabs is not usually necessary unless abnormal design or construction
conditions are encountered.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   240
Garages and Exterior



 14.4

 CONDITION
 GARAGE DOORS DO NOT OPERATE PROPERLY

 Acceptable Performance/Condition
 Overhead garage doors shall manually operate with relative ease without binding. An automatic
 garage door opener supplied and installed by the builder shall not interfere with the emergency
 manual operation of the door.

 Warranty
 One-Year – Work and Materials
 • Damage caused by improper maintenance or additions, deletions or alterations by the
   homeowner is not covered by the statutory warranty.

 Action
 Garage doors not meeting the acceptable performance shall be repaired.

 Remarks
 Proper operation of overhead garage doors should be confirmed at the PDI and any malfunction
 should be noted on the PDI Form to avoid any dispute about whether the damage was caused by
 the builder. The builder is not responsible for the door operation if the homeowner has installed a
 garage door opener.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
241   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.5

CONDITION
GARAGE DOORS (VEHICULAR AND MAN-DOORS) ALLOW ENTRANCE OF SNOW OR WATER

Acceptable Performance/Condition
Garage doors are not required to be weatherstripped and may allow snow and water to
enter the garage.

Warranty
None.

Action
None.

Remarks
Unless a garage is constructed by the builder to be used for habitable space, garage doors
are not required to be weathertight.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   242
Garages and Exterior



 14.6

 CONDITION
 WATER ACCUMULATES ON GARAGE FLOOR

 Acceptable Performance/Condition
 Provided garage floors are sloped to drain to the exterior, minor variations in the surface
 of the floor may impede immediate drainage and are acceptable.

 Warranty
 One-Year – Work and Materials

 Action
 Garage floors not meeting the acceptable condition shall be repaired.

 Remarks
 Closed overhead garage doors, stored materials and debris on the floor may impede drainage
 to the exterior.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
243   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.7

CONDITION
ASPHALT OR CONCRETE DRIVEWAY HAS CRACKED

Acceptable Performance/Condition
Cracks are acceptable if caused by factors other than a defect in work or materials provided
by the builder.

Warranty
One-Year – Work and Materials
• Damage resulting from normal shrinkage of materials caused by drying after construction,
  improper maintenance, normal wear and tear, subsidence of the land around the building,
  or alterations, deletions, or additions made by the homeowner is not covered by the
  statutory warranty.

Action
Cracks not meeting the acceptable condition shall be repaired.

Remarks
The condition is warranted where there is a demonstrated defect in work or material supplied by the
builder. Cracks may develop in driveways due to environmental conditions, soil settlement, de-icing
chemicals, or shrinkage of the asphalt or concrete, and are not warranted in those situations. Heavy
loads from large vehicles can damage driveways.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   244
Garages and Exterior



 14.8

 CONDITION
 DRIVEWAY HAS SETTLED

 Acceptable Performance/Condition
 Driveways shall be graded so that water does not accumulate at or near the building. Subsidence
 in other parts of a driveway is not covered by the statutory warranty.

 Warranty
 One-Year – Work and Materials
 • Subsidence of the land around the building or along utility lines, alterations by the homeowner
   such as landscaping or improper maintenance is excluded from the statutory warranty.

 Action
 Driveways not meeting the acceptable condition shall be repaired.

 Remarks
 Disturbed soil will naturally consolidate and cannot practically be prevented from moving.
 Frost heaves may also produce seasonal movement where the driveway meets the garage.
 Heavy loads imposed on a driveway can cause local depressions.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
245   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.9

CONDITION
SOD/SEEDING NOT COMPLETED

Acceptable Performance/Condition
Sod/seeding shall be installed in conditions conducive to growth, generally within one year
of the occupancy of the home or within the time period required by governing municipal
agreements or the phasing of the subdivision.

Warranty
One-Year – Incomplete Work
One-Year – Work and Materials
• Sod/seeding that fails due to improper maintenance is excluded from the statutory warranty.

Action
Builder shall complete sod/seeding installation when conditions conducive to growth exist.
The installation of sod/seeding can coincide with subdivision phasing.

Remarks
Identify any incomplete landscaping (that is the responsibility of the builder) at the PDI.
Sod/seeding should only be installed when conditions are conducive to growth, typically
mid-spring through mid-fall.
The homeowner is responsible to maintain sod/seeding after installation is complete;
maintenance requirements may vary.
The installation of sod/seeding may be delayed as a result of:
• Homes occupied when conditions are not conducive to growth
• Phasing of sub-division work
• Final grading related to municipal agreements
Growing conditions vary according to geographic location.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   246
Garages and Exterior



 14.10

 CONDITION
 THE SHRUBS, TREE(S), PLANTS, OR SOD HAVE DIED

 Acceptable Performance/Condition
 Landscaping plants supplied and installed by the builder shall be alive at the time of the PDI
 or when installed, whichever is later.

 Warranty
 One-Year – Work and Materials

 Action
 Landscape planting not meeting the acceptable condition shall be replaced.

 Remarks
 Homeowners must water and nurture landscaping plants after installation to ensure growth.
 Plants that are alive when installed and subsequently die are not the responsibility of the builder.
 Plants on municipal property such as boulevards and walkways are not covered by the
 statutory warranty.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
247   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.11

CONDITION
TREE STUMPS HAVE BEEN LEFT ON THE PROPERTY

Acceptable Performance/Condition
Where the builder is responsible for final grading under the contract and trees have been
cut down as part of the construction process, stumps shall be removed.

Warranty
One-Year – Work and Materials

Action
Tree stumps not meeting the acceptable condition shall be removed.

Remarks
Identify any incomplete landscaping (that is the responsibility of the builder) at the PDI.
Reference must be made to the Agreement of Purchase and Sale or construction contract in order
to determine the scope of the builder’s responsibilities.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.new.on.ca   248
Garages and Exterior



 14.12

 CONDITION
 WATER PONDING IN SURFACE GRADING OF THE SITE

 Acceptable Performance/Condition
 The site shall be graded so that water does not accumulate at or near the building. Backfill against
 a foundation shall be graded to prevent drainage towards the building after settling. Where no grade
 is specified for a slope, a minimum gradient of 2% is considered acceptable; sodded or gravelled
 areas may have a minimum gradient of 1%.

 Warranty
 One-Year – Work and Materials
 One-Year – Ontario Building Code Violations
 • Subsidence of the land around the building or along utility lines, alterations by the homeowner
   such as landscaping or improper maintenance is excluded from the statutory warranty.

 Action
 Site grading shall meet the acceptable condition by conforming to a municipally approved
 grading plan, or equivalent, where applicable. After the first year, the homeowner is responsible
 for maintaining the finished site grading to ensure ponding water does not adversely affect
 their premises.

 Remarks
 Ponding may occur because grading may not always be finished at occupancy. Generally,
 municipalities control the grading patterns of building sites and builders must comply with approved
 grading plans for the installation of swales and slopes. Disturbed soil will naturally consolidate and
 cannot practically be prevented from settling; i.e., settlement of walkways and driveways is not
 covered by warranty. However, sufficient soil must be placed around the building to ensure
 acceptable drainage is maintained during the first year after occupancy.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
249   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.13

CONDITION
SETTLING, HEAVING OR SEPARATING OF LANDINGS OR STEPS

Acceptable Performance/Condition
Stairs and landings supported by a foundation shall not heave, settle or separate from the main
building more than 25 mm.
Stairs and landings not requiring a foundation are not restricted from movement.

Warranty
One-Year – Work and Materials
Two-Year – Ontario Building Code Health & Safety Violations
• Settlement and subsidence of the land around the building or along utility lines, other than
  subsidence beneath the footings of the building, is excluded from the statutory warranty.
• Damage resulting from normal shrinkage of materials due to drying after construction is not
  covered by the statutory warranty.

Action
Stairs, landings and decks not meeting the acceptable performance shall be repaired.

Remarks
Concrete stairs having not more than two risers, and small wood stairs not attached to the building
do not require foundations and are often affected by the settlement of supporting backfill – this is
not covered by the statutory warranty.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   250
Garages and Exterior



 14.14

 CONDITION
 EXTERIOR DECK IS SPRINGY OR SHAKY

 Acceptable Performance/Condition
 Exterior decks shall be designed and installed in accordance with the Ontario Building Code.

 Warranty
 One-Year – Work and Materials
 Two-Year – Ontario Building Code Health & Safety Violations

 Action
 Decks not meeting the acceptable performance shall be repaired.

 Remarks
 None.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
251   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.15

CONDITION
EXTERIOR DECK RAILING IS SHAKY

Acceptable Performance/Condition
Exterior deck guards shall be designed and installed in accordance with the Ontario Building Code.

Warranty
Two-Year – Ontario Building Code Health & Safety Violations
• Damage resulting from improper maintenance or additions, deletions or alterations made by the
  homeowner is excluded from the statutory warranty.

Action
Exterior deck railings and guards not meeting the acceptable performance shall be repaired.

Remarks
None.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   252
Garages and Exterior



 14.16

 CONDITION
 DECK BOARD SPACING IS NOT UNIFORM

 Acceptable Performance/Condition
 Deck boards forming the walking surface shall be spaced to provide a generally
 uniform appearance.

 Warranty
 One-Year – Work and Materials
 • Normal shrinkage of materials due to drying after construction is not covered by warranty.

 Action
 Deck boards not meeting the acceptable condition shall be repaired.

 Remarks
 Spacing between boards may be adjusted during installation to allow for construction variances.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
253   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.17

CONDITION
EXTERIOR WOOD HANDRAILS HAVE SLIVERS

Acceptable Performance/Condition
Handrail surfaces meant to be touched shall not have slivers that prevent the handrails
from being grasped.

Warranty
One-Year – Work and Materials
• Damage resulting from normal wear and tear is excluded from warranty.

Action
Handrails not meeting the acceptable condition shall be repaired.

Remarks
This condition is warranted only where there is a demonstrated defect in work or material supplied
by the builder. Small slivers can develop from weathering and can be easily removed by sanding
as part of normal home maintenance.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   254
Garages and Exterior



 14.18

 CONDITION
 EXTERIOR DECK IS OUT OF LEVEL

 Acceptable Performance/Condition
 Exterior decks may slope away from the building a maximum ratio of 50 mm in 3,600 mm
 to shed water.

 Warranty
 One-Year – Work and Materials

 Action
 Exterior decks not meeting the acceptable condition shall be repaired.

 Remarks
 None.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
255   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.19

CONDITION
FLOOR DECKING BOARDS ARE SPLIT, WARPED OR CUPPED

Acceptable Performance/Condition
Floor decking boards may split with exposure to the natural environment.
Floor decking boards shall be fastened securely to minimize warping and cupping.

Warranty
One-Year – Work and Materials
• Damage resulting from improper maintenance, normal shrinkage of materials due to drying
  after construction, or additions, deletions or alterations made by the homeowner is excluded
  from the statutory warranty.

Action
Floor decking boards not meeting the acceptable condition shall be repaired.

Remarks
Floor decking boards may naturally split with exposure to the elements – the condition cannot
reasonably be prevented. The characteristics of some manufactured materials may vary.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   256
Garages and Exterior



 14.20

 CONDITION
 STAIN COLOUR VARIATIONS ON WOOD DECK

 Acceptable Performance/Condition
 Stain on a wood deck shall appear generally uniform in colour. Colour variations are acceptable
 when changing from the horizontal plane to the vertical plane (i.e., from a vertical guard or fence
 to a horizontal deck).

 Warranty
 One-Year – Work and Materials
 • Damage resulting from improper maintenance or additions, deletions or alterations made
   by the homeowner is excluded from the statutory warranty.

 Action
 Stain colour not meeting the acceptable performance shall be repaired.

 Remarks
 Stain colour will fade with exposure to the elements. Stain colour in areas with intense sun
 exposure will vary more than areas that have some protection. Wood is a natural material and
 stain penetration may vary with wood type and grain patterns.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
257   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.21

CONDITION
NAILHEADS STICK UP ON DECK SURFACE

Acceptable Performance/Condition
Nailheads shall be set generally flush with the adjacent deck surface.

Warranty
One-Year – Work and Materials
• Damage resulting from shrinkage of materials is excluded from the statutory warranty.

Action
Nailheads not meeting the acceptable performance shall be repaired.

Remarks
Nailheads on decks will protrude from the surface over time and can be easily reset as part
of regular home maintenance.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   258
Garages and Exterior



 14.22

 CONDITION
 STAINS ON EXTERIOR DECKING FROM NAILHEADS

 Acceptable Performance/Condition
 Nails will discolour or rust with exposure to the natural environment.

 Warranty
 None.

 Action
 None.

 Remarks
 Even galvanized nails can discolour over time and may stain adjacent deck surfaces.

 Words in italics are defined in the “Terminology” section on pages 15-17.




 Notes




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
259   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Garages and Exterior



14.23

CONDITION
TWISTING OF OPEN-END BEAMS

Acceptable Performance/Condition
Twisting of visible open-end beams in excess of 13 mm from plumb is not acceptable.

Warranty
One-Year – Work and Materials
• Twisting resulting from normal shrinkage caused by drying after construction is excluded
  from warranty.

Action
Open-ended beams twisted more than the acceptable condition shall be repaired.

Remarks
An open-end beam is a wood beam whose end does not abut another framing member or
that terminates in open air. Minor twisting is primarily an aesthetic concern rather than a
structural problem.

Words in italics are defined in the “Terminology” section on pages 15-17.




Notes




                                              Construction Performance Guidelines
                                              Second Edition, effective December 1, 2003
                                              For more information, call 1-800-668-0124 or visit www.newhome.on.ca   260
Appendices



 A1 Sources

 The following sources were consulted in the development of the Guidelines.
 1. Ontario Building Code, Ontario Government Bookstore.
 2. Canadian Building Digest, National Research Council Canada.
 3. Building Technology Best Practice Guide, Canada Mortgage and Housing Corporation.
 4. Characteristics of Concrete, Poured Concrete Association/Cement Association of Canada.
 5. Ontario New Home Warranties Plan Act and Regulations.
 6. Focus: Concrete Masonry Units, Ontario Concrete Block Association.
 7. Code and Construction Guide for Housing, Ontario New Home Warranty Program Policies,
     Ontario New Home Warranty Program.
 8. Residential Air System Design Manual, Heating, Refrigerating and Air Conditioning Institute.
 9. Architectural Specification Manual, Ontario Painting Contractors Association.
 10. Problems, Causes, Cures, National Wood Flooring Association.
 11. CAN/CSA-A82.1-M87 “Burned Clay Bricks”, CAN/CSA-A371-94 “Masonry Construction
     for Buildings”, Canadian Standards Association.
 12. 2002 Specification Guide 09300 Tile Installation Manual, Terrazzo, Tile and Marble
     Association of Canada.

 A2 Moisture and Wood Floors

 This information is intended as a guide only.

                                  WOOD FLOORING HAS A COMFORT LEVEL, TOO
  Wood flooring will perform best when the interior environment is controlled to stay within a relative humidity range of
  30 to 50 per cent and a temperature range between 15°C and 27°C. Fortunately, that’s about the same comfort range most
  humans enjoy. The chart below indicates the moisture content wood will likely have at any given combination of temperature
  and humidity. Note that equilibrium moisture contents in the recommended temperature/humidity range (shaded area)
  coincide with the 6 to 9 per cent range within which most hardwood flooring is manufactured. Although some movement
  can be expected even between 6 and 9 per cent, wood can expand and shrink dramatically outside that range.

 Table 1

                                  MOISTURE CONTENT OF WOOD
                    AT VARIOUS TEMPERATURES AND RELATIVE HUMIDITY READINGS
  Temperature (Celsius)
  -2    1.4   2.6   3.7    4.6   5.5   6.3    7.1   7.9   8.7    9.5 10.4 11.3 12.4         13.5   14.9   16.5   18.5   21.0   24.3   26.9
   4    1.4   2.6   3.7    4.6   5.5   6.3    7.1   7.9   8.7    9.5 10.4 11.3 12.4         13.5   14.9   16.5   18.5   21.0   24.3   26.9
  10    1.4   2.6   3.7    4.6   5.5   6.3    7.1   7.9   8.7    9.5 10.4 11.3 12.4         13.5   14.9   16.5   18.5   21.0   24.3   26.9
  15    1.3   2.5   3.6    4.6   5.4   6.2    7.0   7.8   8.6    9.4 10.2 11.1 12.1         13.3   14.6   16.2   18.2   20.7   24.1   26.8
  21    1.3   2.5   3.5    4.5   5.4   6.2    6.9   7.7   8.5    9.2 10.1 11.0 12.0         13.1   14.4   16.0   17.9   20.5   23.9   26.6
  27    1.3   2.4   3.5    4.4   5.3   6.1    6.8   7.6   8.3    9.1   9.9    10.6 11.7     12.9   14.2   15.7   17.7   20.2   23.6   26.3
  32    1.2   2.3   3.4    4.3   5.1   5.9    6.7   7.4   8.1    8.9   9.7    10.5 11.5     12.6   13.9   15.4   17.3   19.8   23.3   26.0
  38    1.2   2.3   3.3    4.2   5.0   5.8    6.5   7.2   7.9    8.7   9.5    10.3 11.2     12.3   13.6   15.1   17.0   19.5   22.9   25.6
         5    10    15     20    25    30     35    40     45     50   55      60      65    70     75     80     85     90     95     98
                                                          Relative Humidity (per cent)

  Chart taken from National Wood Flooring Association Technical Publication No. A100.




       Construction Performance Guidelines
       Second Edition, effective December 1, 2003
261    For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Appendices



A3 Moisture and Windows

This chart identifies the maximum relative humidity for a given inside temperature above which
condensation will form on windows. For additional information, see the Canada Mortgage and
Housing Corporation’s (CMHC) pamphlet Moisture and Air, Problems and Remedies, available by
request from CMHC or at their website www.cmhc-schl.gc.ca

Table 2
                                                                           Inside Temperature
                                                   20oC                            22oC                            24oC
      Outside                                               MAXIMUM RELATIVE HUMIDITY (%)
    Temperature                       SINGLE              DOUBLE         SINGLE            DOUBLE        SINGLE           DOUBLE
       (oC)                           GLASS                GLASS         GLASS              GLASS        GLASS             GLASS
              - 35                       3                   18             3                 18            3                18
              - 29                       5                  23                 5             22              5               21
              - 23                       8                  27                 7             26              6               25
              - 18                      12                  33                11             31             10               29
              - 12                      17                  39                16             37             15               35
              -7                        24                  46                23             44             22               42
              -1                        34                  55                32             52             30               49




A4 Measuring Variation from the Specified Plane Using a Plane of Reference

To measure the variation:
   1) Place two blocks of equal thickness on either side of the surface you are considering.
   2) Stretch a string across the top of the blocks so the string doesn’t sag; the blocks may
      have to be secured from moving.
   3) Measure the difference between the string and the actual surface and subtract the
      thickness of the blocks.
   4) Compare the result with the allowable variation in the Guidelines.
                            Reference Plane (string)
      Block                                                                                                                 Block



                                                                         Specified Plane
                     Actual Surface




Figure 1. Measuring actual surface variation from a specified plane using a plane of reference.




                                                           Construction Performance Guidelines
                                                           Second Edition, effective December 1, 2003
                                                           For more information, call 1-800-668-0124 or visit www.newhome.on.ca     262
Appendices



 A5 How to Conduct a Water Test

 A water test shall be performed to confirm water leaks, both above and below grade. Above grade
 the intent is to simulate an average, wind-driven rainfall but should never be done using full
 pressure in a single-stream or pressure-altering device such as a pressure washer. This can force
 water through building assemblies and flashings not intended for high-volume or high-pressure
 water saturation. Below grade the intent is to simulate natural water flow around a foundation
 caused by rain or snow melting where the water may inadvertently be directed towards the
 foundation wall. Water penetration is considered to be bulk water coming into the basement or
 accumulating near the point of entry, or dampness on the wall appearing as a result of the test,
 but excludes dampness caused by condensation or other causes.

 Above Grade
 Use a standard garden hose and sprayer attachment. The sprayer attachment should be set on
 “shower” or other similar dispersal pattern. Spray the area to be tested for not more than 10 minutes
 from a minimum distance of 2 m. Have another person checking inside for the point of origin and
 the length of time it takes for water to appear. Areas to be investigated should be kept dry prior to
 the test.

 Below Grade
 Use a standard garden hose with no attachments. The hose bib should be set at about half flow to
 simulate melting snow or rainfall. The water from the hose is to be directed along the face of the
 foundation to allow the water to run parallel to the wall, at grade, finding its own way down the
 exterior of the wall to the perimeter foundation drains. Run the water for not more than 20 minutes
 checking periodically for water penetration. Identify the location and the point of entry of any water
 (crack, tie rod, snap tie, honeycombing) and the length of time it takes for water to appear.




      Construction Performance Guidelines
      Second Edition, effective December 1, 2003
263   For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Appendices



A6 Chipped Clay Bricks

The following table is from Canadian Standards Association, CSA A82.1-M87, “Burned Clay Bricks”.

Table 3

                                   CLAY BRICK
                MAXIMUM PERMISSIBLE EXTENT1 OF CHIPPAGE FROM THE
        EDGES AND CORNERS OF THE FINISHED FACE OR FACES ONTO THE SURFACE
                                        Chippage in millimetres                                      Chippage in millimetres
                                        (inches) in from                                             (inches) in from
                      Maximum                                                     Remaining
                     percentage                                                   percentage
       Type           allowed* §              Edge               Corner            allowed* §              Edge               Corner
        (1)               (2)                  (3)                (4)                  (5)                  (6)                (7)
       FBS2                                6.35 – 7.94          9.53 – 12.7                               0 – 6.35            0 – 9.53
                       10% or less                                                  90 – 100%
     (Smooth)†                             (1/4 – 5/16)         (3/8 – 1/2)                               (0 – 1/4)           (0 – 3/8)
       FBS2                                 7.94 – 11.1         12.7 – 19.1                               0 – 7.94            0 – 12.7
                       15% or less                                                  85 – 100%
     (Rough)‡                              (5/16 – 7/16)        (1/2 – 3/4)                              (0 – 5/16)           (0 – 1/2)

* Percentage of exposed brick allowed in the wall with chips measured the listed dimensions in from an edge or corner.
†   Smooth texture is the unbroken natural die finish.
‡   Rough texture is the finish produced when the face is sanded, combed, scratched, or scarified, or the die skin on
    the face is entirely broken by mechanical means such as wire cutting or wire brushing.
§   Of all the units that will be exposed in place, a small percentage of the units may have chips that range in size
    greater than that allowed for the majority of the units. This special allowed percentage, as shown in the second
    column from the left, ranges up to 10% for FBS (smooth), and up to 15% for FBS (rough). The rest of the units
    that will be exposed in place, as shown in the 5th column from the left, just conform to the maximum allowed
    chippage shown in the 6th and 7th columns from the left.
    Example: The units to be placed into the wall should be inspected prior to being placed. The FBS (smooth) units
    will then conform to the requirements of this Table if not more that 10% of the units have edge chips greater than
    6.35 mm (1/4") but less than 7.94 mm (5/16") and the remainder of the units, in this example 90% (100% - 10%),
    do not have edge chips greater than 6.35 mm (1/4") in from the edge or 9.53 mm (3/8") in from the corner.

Notes
1. The aggregate length of chips shall not exceed 10% of the perimeter of the face of the brick
    (CAN/CSA-A82.1-M87, s.7.3).
2. Type FBS brick is the most common type of brick used in residential construction. They are used in exposed
    exterior and interior masonry walls where wider colour ranges and greater variation in sizes are allowed
    (CAN/CSA-A82.1-M87, s.4.1.2). For other types of bricks, refer to CAN/CSA-A82.1-M87.

With the permission of Canadian Standards Association, material is reproduced from CSA Standard CAN/CSA-A82.1-M87, which is copyrighted by
Canadian Standards Association, 178 Rexdale Blvd., Toronto, Ontario, M9W 1R3, www.csa.ca. While use of this material has been authorized, CSA
shall not be responsible for the manner in which the information is presented, nor for any interpretations thereof.




                                                        Construction Performance Guidelines
                                                        Second Edition, effective December 1, 2003
                                                        For more information, call 1-800-668-0124 or visit www.newhome.on.ca               264
Appendices



  Using a representative sample to determine the percentages of affected bricks in Table 3.

  A representative sample may be used to determine the percentage of bricks (Columns (2) and (5)
  in Table 3) that have chips of specified sizes.

  The representative sample (versus an isolated section of the wall with the chipped brick problem)
  shall be 1 m x 1 m in size with the centre of the sample located 1.5 m (5') above the foundation in
  the middle of the wall. If the sample lands on an opening (window, door, etc), it shall be moved
  horizontally in the direction of the most brick in the sample so a full square metre of brick is sampled.

  Individual bricks must still meet the maximum chip dimensions in Table 3.



  Illustrating Brick Chippage

  These illustrations are colour-coded to help describe the information in Table 3.



                                                      90%-100%                                                              85%-100%
                                                      of the bricks                                                         of the bricks
                                                        can have                                                              can have
                                                        chips up                                                              chips up
                                                        to 3/8" in                                                              to 1/2"
                                                        from the                                                               in from
                                                          corner                                                             the corner




                       Smooth                           Not more                            Rough                             Not more
                       Bricks †                         than 10%                            Bricks ‡                          than 15%
                                                      of the bricks                                                         of the bricks
                                                        can have                                                              can have
                                                     chips between                                                         chips between
                                                         3/8"-1/2”                                                             1/2"-3/4"
                                                          in from                                                               in from
                                                       the corner                                                            the corner




 Not more than 10%               90%-100% of the                      Not more than 15%                85%-100% of the
  of the bricks can               bricks can have                      of the bricks can                bricks can have
 have chips that are              chips up to 1/4"                    have chips that are              chips up to 5/16"
 between 1/4"-5/16"              in from the edge                     between 5/16"-7/16"              in from the edge
  in from the edge                                                      in from the edge




        Construction Performance Guidelines
        Second Edition, effective December 1, 2003
265     For more information, call 1-800-668-0124 or visit www.newhome.on.ca
Appendices



A7 Industry Agencies

The following residential building industry agencies contributed to the development of the Guidelines.

Technical Standard Sub-committee of the Ontario Home Builders’ Association/Ontario New Home
Warranty Program Liaison Committee

Canadian Carpet Institute                                Ready Mixed Concrete Association of Ontario
Canadian Plywood Association                             Residential Carpentry Contractors Association
Canadian Window and Door Manufacturers                   of Greater Toronto
Association                                              Residential Construction Control Council
Cement Association of Canada                             of Central Ontario
Concrete Forming Association of Ontario                  Residential Framing Contractors Association
                                                         of Metropolitan Toronto & Vicinity
Heating, Refrigeration & Air Conditioning Institute
                                                         Residential Roofing Contractors Association
Independent Plumbing & Heating Contractors’
                                                         of Greater Metropolitan Toronto
Association
                                                         Residential Siding Contractors Association
Low Rise Forming Association
                                                         of Greater Metropolitan Toronto
Mechanical Contractors Association of Ontario
                                                         Siding and Window Dealers Association
National Wood Flooring Association                       of Canada
Ontario Concrete Block Association                       Structural Board Association
Ontario Masonry Contractor’s Association                 Terrazzo, Marble and Tile Association of Canada
Ontario Painting Contractors Association                 The Concrete Floor Contractors Association
                                                         of Ontario




                                           Construction Performance Guidelines
                                           Second Edition, effective December 1, 2003
                                           For more information, call 1-800-668-0124 or visit www.newhome.on.ca   266
SECOND EDITION
EFFECTIVE DECEMBER 1, 2003

More Related Content

DOCX
Khóa luận một số giải pháp nhằm nâng cao hoạt động marketing mix tại công ty ...
PDF
Giải pháp hoàn thiện hiệu quả hoạt động Marketing mix tại công ty cổ phần chè...
DOCX
Phân tích hoạt động xúc tiến hỗn hợp tài công ty TNHH lữ hành Golden Life
DOC
Nghiên cứu phát triển du lịch sinh thái gắn với bảo tồn đa dạng sinh học tại ...
PDF
Đồ án Quản trị Marketing Phân tích việc thực hiện chương trình marketing cho ...
PPTX
Hoạch định chiến lược PR
DOC
Lập kế hoạch marketing cho khách sạn Vinpearl Resort Phú Quốc trong năm 2015
DOCX
Hoàn thiện chiến lược marketing tại công ty Bất động sản Gia, HAY!
Khóa luận một số giải pháp nhằm nâng cao hoạt động marketing mix tại công ty ...
Giải pháp hoàn thiện hiệu quả hoạt động Marketing mix tại công ty cổ phần chè...
Phân tích hoạt động xúc tiến hỗn hợp tài công ty TNHH lữ hành Golden Life
Nghiên cứu phát triển du lịch sinh thái gắn với bảo tồn đa dạng sinh học tại ...
Đồ án Quản trị Marketing Phân tích việc thực hiện chương trình marketing cho ...
Hoạch định chiến lược PR
Lập kế hoạch marketing cho khách sạn Vinpearl Resort Phú Quốc trong năm 2015
Hoàn thiện chiến lược marketing tại công ty Bất động sản Gia, HAY!

Similar to Tarion Performance Guidelines (20)

PDF
Masonry homes construction manual
PDF
PDF
Tarion Construction Performance Guidelines 3rd edition 2012 final
PDF
Falhas de rolamentos.pdf
PDF
Wcd1 300
PDF
AERODYNAMIC DEVELOPMENT OF THE SEGURACING F1-R01 PROTOTYPE USING CFD
PDF
Preliminary Design of a FOWT
PDF
Fiberglass-Manual-2015.pdf
PDF
Albion sections cold formed steel
PDF
szza009 (1).pdfdsrgggsdggggggggggggggggggggggg
PDF
ASC Skyline Roofing Installation Manual
PDF
Engineering BIOCHAR.pdf
PDF
PCI parking structures recommended practices
PDF
Precast carparks
PDF
Panduan sketcup
PDF
Guide for the design of crane supporting steel structures
PDF
Structural Concetps and system
PDF
Hollow core slabs
PDF
Woods towoodshop
PDF
House framing guidelines
Masonry homes construction manual
Tarion Construction Performance Guidelines 3rd edition 2012 final
Falhas de rolamentos.pdf
Wcd1 300
AERODYNAMIC DEVELOPMENT OF THE SEGURACING F1-R01 PROTOTYPE USING CFD
Preliminary Design of a FOWT
Fiberglass-Manual-2015.pdf
Albion sections cold formed steel
szza009 (1).pdfdsrgggsdggggggggggggggggggggggg
ASC Skyline Roofing Installation Manual
Engineering BIOCHAR.pdf
PCI parking structures recommended practices
Precast carparks
Panduan sketcup
Guide for the design of crane supporting steel structures
Structural Concetps and system
Hollow core slabs
Woods towoodshop
House framing guidelines
Ad

Recently uploaded (20)

PPTX
Celebrate Independence Day in Premium Apartments in Kerala
PPTX
Classifying Objects and Events or Situations.pptx
PPTX
Startup Business Plan Neon Green and White Modern Minimal Presentation.pptx
PDF
Evolving Illinois Rental Market: Trends and Opportunities for Landlords
PDF
Real Estate Investment in Trichy – Why 2025 is the Best Time to Invest.pdf
PDF
Collaborating-for-a-Better-Future-Cross-Sector-Partnerships-in-Miami.pdf
PDF
Surprising Truth About the Average House Price by State in 2025.pdf
PDF
2, 3, and 4 BHK Superior Apartment in Coimbatore
PDF
Mansory Residences at Meydan City – AMAAL
PPTX
Introduction_to_Property_Management.pptx
PDF
Interstellar Tower at JVT, Dubai – Mr Eight Development
PPTX
Tangled Up in Green Luxury Developments
PDF
Bhartiya City Nikoo Homes 6 & 7 - Iconic Luxury Apartments in the Heart of No...
PDF
Binghatti Aquarise at Business Bay, Dubai – Binghatti Developers.pdf
PDF
Embracing the Circular Economy: A Homeowners Guide to Sustainable Living
PDF
MSN Realty 4 BHK Luxury Apartments in Neopolis Hyderabad | Premium Homes with...
PPTX
Estate_Agent_Power_Presentation_Branding.pptx
PDF
Luxera Bahceport Project - Listing Turkey
PDF
Skyvue Stellar at Sobha Hartland 2, Dubai – Sobha Group
PDF
The Serene at Jabal Ali – Sobha Realty
Celebrate Independence Day in Premium Apartments in Kerala
Classifying Objects and Events or Situations.pptx
Startup Business Plan Neon Green and White Modern Minimal Presentation.pptx
Evolving Illinois Rental Market: Trends and Opportunities for Landlords
Real Estate Investment in Trichy – Why 2025 is the Best Time to Invest.pdf
Collaborating-for-a-Better-Future-Cross-Sector-Partnerships-in-Miami.pdf
Surprising Truth About the Average House Price by State in 2025.pdf
2, 3, and 4 BHK Superior Apartment in Coimbatore
Mansory Residences at Meydan City – AMAAL
Introduction_to_Property_Management.pptx
Interstellar Tower at JVT, Dubai – Mr Eight Development
Tangled Up in Green Luxury Developments
Bhartiya City Nikoo Homes 6 & 7 - Iconic Luxury Apartments in the Heart of No...
Binghatti Aquarise at Business Bay, Dubai – Binghatti Developers.pdf
Embracing the Circular Economy: A Homeowners Guide to Sustainable Living
MSN Realty 4 BHK Luxury Apartments in Neopolis Hyderabad | Premium Homes with...
Estate_Agent_Power_Presentation_Branding.pptx
Luxera Bahceport Project - Listing Turkey
Skyvue Stellar at Sobha Hartland 2, Dubai – Sobha Group
The Serene at Jabal Ali – Sobha Realty
Ad

Tarion Performance Guidelines

  • 1. SECOND EDITION EFFECTIVE DECEMBER 1, 2003 Construction Performance Guidelines for the Ontario Home Building Industry www.newhome.on.ca
  • 2. Table of Contents INTRODUCTION Purpose of this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Scope of the Construction Performance Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Scope of Warranty Responsibilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Statutory Warranty Coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Conditions Not Covered Under Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Incomplete, Missing or Damaged Items – Pre-Delivery Inspection (PDI) . . . . . . . . . . . . . . . . . . . . 13 How to Use this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 PERFORMANCE GUIDELINES 1. FOUNDATION/BASEMENT 1.1 Efflorescence is present on concrete or masonry surfaces . . . . . . . . . . . . . . . . . . . 18 1.2 Interior concrete surfaces are powdery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1.3 Concrete surface is flaking off or “scaling” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 1.4 Concrete floor without builder-applied finished flooring in basement is uneven . . . . 21 1.5 Concrete basement floor is cracked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 1.6 Concrete floor slab-on-ground has settled in a finished area . . . . . . . . . . . . . . . . . . 23 1.7 No reinforcing in basement concrete slab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 1.8 Concrete block foundation wall is cracked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 1.9 Parging (not brush coating) is falling off above grade . . . . . . . . . . . . . . . . . . . . . . . . 26 1.10 Exposed cast-in-place concrete foundation wall has holes in the surface . . . . . . . . 27 1.11 Cast-in-place concrete foundation wall is cracked . . . . . . . . . . . . . . . . . . . . . . . . . . 28 1.12 Condensation in crawl space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 1.13 Basement wall or floor is damp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 1.14 Foundation wall leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 1.15 Water leakage through basement floor slab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 2. FLOOR FRAMING 2.1 Wood beam or post is split . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 2.2 Wood beam or post is cupped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 2.3 Structural column in unfinished basement is out of plumb . . . . . . . . . . . . . . . . . . . . 35 2.4 Floor framing damaged by weather during construction. . . . . . . . . . . . . . . . . . . . . . 36 2.5 Loose subfloor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 2.6 Floor squeaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 2.7 Finished floor above grade is out of level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 2.8 Springiness, bounce, visible sag when loaded, or shaking is observed in the floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 1
  • 3. Table of Contents 3. WALL FRAMING 3.1 Wall is out of plumb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 3.2 Wall is bowed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 3.3 Malfunction of windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 3.4 Window glass and/or screen is damaged . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 3.5 Glass is scratched . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 3.6 Glass is cracked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 3.7 Window unit leaks during rain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 3.8 Condensation forming between insulating (factory sealed) unit . . . . . . . . . . . . . . . . 48 3.9 Exterior door is warped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 3.10 Exterior metal door is dented . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 3.11 Shrinkage of inserted panels shows raw wood edges on exterior wood doors . . . . 51 3.12 Cracks and splits in exterior wood doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 3.13 Exterior door sticks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 3.14 Exterior door will not close completely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 3.15 Plastic moulding on exterior door is deformed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 3.16 Exterior door swings open or closed by itself . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 3.17 Exterior door is crooked in the frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 3.18 Exterior door hardware or decorative metal trim has discoloured . . . . . . . . . . . . . . . 58 3.19 Sliding door screen will not stay on track or sliding door does not roll smoothly . . . 59 4. EXTERIOR FINISHING 4.1 Wood or hardboard, or panel-type siding is bowed or wavy . . . . . . . . . . . . . . . . . . . 60 4.2 Wood or hardboard or panel-type siding – joints not tight . . . . . . . . . . . . . . . . . . . . 61 4.3 Wood or hardboard or panel-type siding – fasteners are excessively countersunk into finished surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 4.4 Lap siding (wood, hardboard, vinyl, etc.) is not installed on a straight line . . . . . . . . 63 4.5 Tongue and groove wood siding has buckled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 4.6 Wood siding – fastener has stained siding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 4.7 Cedar shakes or shingles have “bled” through paint or stain applied by builder . . . . 66 4.8 Plywood or veneer siding has delaminated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 4.9 Aluminum/vinyl siding is bowed or wavy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 4.10 Aluminum or vinyl siding – colour is faded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 4.11 Aluminum or vinyl siding, trim or accessory is loose . . . . . . . . . . . . . . . . . . . . . . . . 70 4.12 Aluminum or vinyl siding trim and accessories – fasteners don’t match siding colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 4.13 Above-grade masonry wall or veneer cladding (including mortar) is cracked . . . . . . 72 4.14 Cut bricks are of different thickness in relation to one another . . . . . . . . . . . . . . . . . 73 4.15 Horizontal masonry joint alignment is not uniform . . . . . . . . . . . . . . . . . . . . . . . . . . 74 4.16 Mortar splatters and stains on exterior masonry . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Construction Performance Guidelines Second Edition, effective December 1, 2003 2 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 4. Table of Contents 4. EXTERIOR FINISHING (continued) 4.17 Efflorescence (white powder) is present on masonry surface . . . . . . . . . . . . . . . . . 76 4.18 Deteriorating masonry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 4.19 Water leakage at doors or windows or at the top of the foundation . . . . . . . . . . . . . 78 4.20 Clay bricks are chipped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 4.21 Bricks are different colours . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 4.22 Cracks in exterior stucco wall surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 4.23 Exterior stucco is peeling or bubbling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 4.24 Unsealed gaps between dissimilar cladding materials and penetrations through cladding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 4.25 Exterior wood trim is split . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 4.26 Exterior wood trim is bowed, twisted or cupped . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 4.27 Paint on repaired areas doesn’t match . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 4.28 Exterior paint, stain or clear finish blisters and peels . . . . . . . . . . . . . . . . . . . . . . . . 87 4.29 Exterior paint or stain has faded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 4.30 Mould or mildew is visible on exterior painted surfaces . . . . . . . . . . . . . . . . . . . . . . 89 4.31 Leak in exterior wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 5. ROOFS 5.1 Roof ridge has sagged . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 5.2 Roof trusses or rafters are bowed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 5.3 Roof appears wavy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 5.4 Leaks due to snow or rain driven into attic through louvers or vents . . . . . . . . . . . . 94 5.5 Roof or flashing leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 5.6 Inadequate attic ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 5.7 Ice buildup on the roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 5.8 Roof shingles have blown off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 5.9 Tabs on asphalt shingles are not lined up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 5.10 Asphalt shingles not sealed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 5.11 Asphalt shingle edges are curled or cupped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 5.12 Asphalt shingles either do not overhang the edge of the roof or hang over too far . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 5.13 Shading pattern is visible on an asphalt shingle roof . . . . . . . . . . . . . . . . . . . . . . . 103 5.14 Variation in colour after repairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 5.15 Uneven roof sheathing causing visible irregularities in the roof surface . . . . . . . . . 105 5.16 Roofing nails are exposed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 5.17 Temporary safety straps left on roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 5.18 Water is trapped under roofing membrane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 5.19 Asphalt roll roofing is blistered but does not admit water . . . . . . . . . . . . . . . . . . . . 109 5.20 Standing water on a flat roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 3
  • 5. Table of Contents 5. ROOFS (continued) 5.21 Eavestroughs or downspouts leak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 5.22 Eavestroughs overflow during normal rain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 5.23 Eavestroughs or downspouts not performing properly . . . . . . . . . . . . . . . . . . . . . . 113 5.24 Eavestroughs don’t drain completely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 5.25 Skylight leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 6. PLUMBING 6.1 Inadequate water supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 6.2 The domestic water supply system does not deliver water . . . . . . . . . . . . . . . . . . . 117 6.3 Pipes are leaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 6.4 Faucet or fixture is leaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 6.5 Plumbing pipes are frozen and/or burst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 6.6 Bathtub or shower leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 6.7 Condensation appears on water supply pipes and toilets . . . . . . . . . . . . . . . . . . . . 122 6.8 Noisy water pipes or “water hammer” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 6.9 Defective plumbing fixtures, appliances or trim fittings . . . . . . . . . . . . . . . . . . . . . . 124 6.10 Cracking or chipping of porcelain, enamel or fibreglass surfaces . . . . . . . . . . . . . . 125 6.11 Lightweight (fibreglass and acrylic) bathtub or shower base flexes and creaks . . . 126 6.12 Manufactured solid-surface countertop (integrated basin) cracks at the drain . . . . 127 6.13 Toilet takes more than one flush to empty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 6.14 Sewers, drains or fixtures blocked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 7. ELECTRICAL 7.1 Fuses blow or circuit breakers trip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 7.2 Ground-fault circuit interrupter (GFCI) trips frequently . . . . . . . . . . . . . . . . . . . . . . 131 7.3 Electrical outlets or switches don’t work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 7.4 Electrical fixture doesn’t work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 7.5 Receptacle/switch cover plate is not flush with the wall . . . . . . . . . . . . . . . . . . . . . 134 7.6 Exhaust fan duct terminates in attic or crawl space . . . . . . . . . . . . . . . . . . . . . . . . 135 7.7 Interior light fixture tarnished . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 7.8 Ceiling fan vibrates and is noisy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 Construction Performance Guidelines Second Edition, effective December 1, 2003 4 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 6. Table of Contents 8. INTERIOR CLIMATE CONTROL 8.1 Draft felt at electrical outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 8.2 Air infiltration through doors and windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 8.3 Kitchen or bath fans allow cold air infiltration or drafts . . . . . . . . . . . . . . . . . . . . . . 140 8.4 Condensation in attic space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 8.5 Condensation and/or frost on windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 8.6 Condensation on interior ductwork and air handling equipment . . . . . . . . . . . . . . . 143 8.7 Insufficient insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 8.8 Heating, ventilating and air conditioning (HVAC) systems not installed properly . . . 145 8.9 Inadequate heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 8.10 Inadequate cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 8.11 Noisy ductwork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 8.12 Ductwork makes noise when someone walks on the floor – commonly known as “oil canning” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 8.13 Noise can be heard at register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 8.14 Ductwork comes apart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 8.15 Condensate line is blocked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 8.16 Air conditioning coolant line leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 8.17 There are gaps between heat diffusers, cold air return grilles and ventilation grilles and the adjacent surface. . . . . . . . . . . . . . . . . . . . . . . . . . . 154 9. WALL AND CEILING FINISH 9.1 Ceiling is uneven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 9.2 Ceiling texture is unevenly applied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 9.3 Gypsum wallboard corners are uneven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 9.4 Cracks in interior wall and ceiling surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158 9.5 Ceiling/wall joint separation commonly referred to as “truss uplift” . . . . . . . . . . . . . 159 9.6 Drywall surface blemishes including nail/screw pops, blisters in taped joints, trowel marks, excess joint compound and dents or gouges . . . . . . . . . . . . . . . . . 160 9.7 Texture of painted gypsum wallboard varies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 9.8 Finished surface is rough . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 9.9 Paint finish is unacceptable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 9.10 Clear interior finishes have deteriorated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 9.11 Paint is splattered on surfaces not intended to be painted . . . . . . . . . . . . . . . . . . . 165 9.12 Wallcovering is peeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 9.13 Patterns in wallcovering are mismatched at the edges . . . . . . . . . . . . . . . . . . . . . . 167 9.14 Water penetration behind ceramic tile and bathtub or shower enclosures . . . . . . . 168 9.15 Mildew or fungus is visible on interior surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 5
  • 7. Table of Contents 10. INTERIOR FINISHING 10.1 Interior door is warped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 10.2 Bi-fold and sliding doors come off tracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 10.3 Pocket door rubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 10.4 Door rubs on the doorjamb or does not latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 10.5 Wood door panel has split . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 10.6 Door drags on the floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 10.7 Gap between the door and the doorjamb is not uniform . . . . . . . . . . . . . . . . . . . . . 176 10.8 Interior door swings open or closed by itself . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 10.9 Doors bind from improperly installed hinges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 10.10 Hinges are painted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 10.11 Gaps exist between stair parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 10.12 Squeaking stair riser or tread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 10.13 Gaps exist between railing parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 10.14 Stair railings lack rigidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 10.15 Joint quality of interior trim work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184 10.16 Nailheads and fasteners are not properly set or filled . . . . . . . . . . . . . . . . . . . . . . . 185 10.17 Interior trim is split . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186 10.18 Hammer marks are visible on trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 10.19 Resin bleeding through painted finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 10.20 Wall area around cold room door is unfinished. . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 11. CABINETS AND COUNTERTOPS 11.1 Gap between cabinets and ceilings or walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 11.2 Cabinets do not line up with each other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 11.3 Cabinet doors and drawer faces are warped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 11.4 Cabinet door or drawer binds or rubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 11.5 Cabinet doors will not stay closed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 11.6 Laminated countertop is swelled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 11.7 Laminated countertop is delaminated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 11.8 Cracks in countertop surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 11.9 Scratches/chips on countertops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 12. FLOORING 12.1 Transition between different types of flooring is not flush . . . . . . . . . . . . . . . . . . . . 199 12.2 Floor is uneven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 12.3 Pattern of finished flooring is out of alignment with adjacent wall surfaces . . . . . . 201 12.4 Carpet seam is visible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 12.5 Carpet is loose or stretching has occurred . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 12.6 Spots or fading on carpet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 Construction Performance Guidelines Second Edition, effective December 1, 2003 6 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 8. Table of Contents 12. FLOORING (continued) 12.7 Carpet not uniform in colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 12.8 Carpet has dark stains around perimeter of rooms and at heating registers . . . . . 206 12.9 Hollow areas in underpad below carpet surface . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 12.10 Protrusions appear on the surface of resilient flooring without breaking through . . 208 12.11 Resilient sheet flooring is loose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 12.12 Resilient flooring joints not tight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 12.13 Bubbles appear on vinyl flooring surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 12.14 Patterns on sheet vinyl flooring are not aligned across seams . . . . . . . . . . . . . . . . 212 12.15 Resilient (flexible) floor tile is loose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 12.16 Patterns or corners of resilient floor tile are misaligned . . . . . . . . . . . . . . . . . . . . . 214 12.17 Yellowing appears on surface of vinyl flooring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 12.18 Dye lot variations in vinyl flooring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 12.19 Variation in colour occurring during repair of vinyl flooring . . . . . . . . . . . . . . . . . . . 217 12.20 Cracks developing between strips of hardwood or parquet flooring . . . . . . . . . . . . 218 12.21 Strip hardwood flooring is cupped (high edges) . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 12.22 The surface of one strip of hardwood or parquet flooring is higher than another . . . 220 12.23 Floor finish on wood flooring is not uniform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 12.24 Finish on wood flooring has blistered, bubbled, or peeled resulting in detachment of finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 12.25 Crowning of strip hardwood flooring has occurred (centre of strip is higher than edges) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 12.26 Wood flooring buckles and detaches from substrate . . . . . . . . . . . . . . . . . . . . . . . 224 12.27 Knots and colour variation in strip wood flooring . . . . . . . . . . . . . . . . . . . . . . . . . . 225 12.28 Splinters occur in strip wood flooring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 12.29 “Sticker burn” appears on surface of strip flooring . . . . . . . . . . . . . . . . . . . . . . . . . 227 12.30 Ceramic/porcelain tile, marble or stone flooring is broken or loose (including marble transitions) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228 12.31 Cracks appearing in grouting of ceramic tile joints or at junctions with other materials such as bathtubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 12.32 Adjacent marble units or ceramic tile surfaces installed at different elevations . . . 230 12.33 Grout is not a uniform colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 13. CHIMNEYS AND FIREPLACES 13.1 Joint or crack in chimney cap allows water leak . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 13.2 Roof flashing leaks at chimney . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 13.3 Bricks breaking up on surface of chimney . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 13.4 Chimney serving solid-fuel-burning (wood, pellet, etc.) appliance does not draw properly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 13.5 Fireplace firebox paint colour changed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 13.6 Firebrick is broken . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 7
  • 9. Table of Contents 14. GARAGES AND EXTERIOR 14.1 Garage floor has heaved or settled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 14.2 Concrete garage floor is cracked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239 14.3 No reinforcing in garage slab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 14.4 Garage doors do not operate properly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 14.5 Garage doors (vehicular and man-doors) allow entrance of snow or water . . . . . . 242 14.6 Water accumulates on garage floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 14.7 Asphalt or concrete driveway has cracked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 14.8 Driveway has settled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245 14.9 Sod/seeding not completed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 14.10 The shrubs, tree(s), plants, or sod have died . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 14.11 Tree stumps have been left on the property . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248 14.12 Water ponding in surface grading of the site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249 14.13 Settling, heaving or separating of landings or steps . . . . . . . . . . . . . . . . . . . . . . . . 250 14.14 Exterior deck is springy or shaky . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251 14.15 Exterior deck railing is shaky . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252 14.16 Deck board spacing is not uniform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253 14.17 Exterior wood handrails have slivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 14.18 Exterior deck is out of level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 14.19 Floor decking boards are split, warped or cupped . . . . . . . . . . . . . . . . . . . . . . . . . 256 14.20 Stain colour variations on wood deck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 14.21 Nailheads stick up on deck surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258 14.22 Stains on exterior decking from nailheads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 14.23 Twisting of open-end beams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260 APPENDICES A1 Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 A2 Moisture and Wood Floors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 A3 Moisture and Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 A4 Measuring Variation from the Specified Plane Using a Plane of Reference . . . . . . . . . . . 262 A5 How to conduct a water test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263 A6 Chipped Clay Bricks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264 A7 Industry Agencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266 Construction Performance Guidelines Second Edition, effective December 1, 2003 8 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 10. Introduction PURPOSE OF THIS DOCUMENT The Construction Performance Guidelines for the Ontario Home Building Industry (“Construction Performance Guidelines” or “Guidelines”) will be used by the Ontario New Home Warranty Program (the “Warranty Program”) when determining whether or not a condition is covered by the statutory warranty. The purpose of the Guidelines is not to set new standards but to provide advance information as to how the Warranty Program will decide disputes between builders and homeowners about defects in work or materials. These Guidelines have been prepared in consultation with various trade and industry groups and the Warranty Program is grateful for their input. A list of the organizations that were consulted is included in Appendix A. The Guidelines provide objective and uniform criteria that set out the minimum performance required in the construction of new homes in Ontario. They relate to work and materials deficiencies and complement the Ontario Building Code, which addresses structural integrity and health and safety matters. In any case where a guideline is not consistent with a provision of the Ontario Building Code, the Ontario Building Code will prevail. The Guidelines are designed to be supplemented by any applicable guidelines or standards produced by industry associations. They do not replace manufacturer warranties. The Guidelines are designed primarily for conventional low-rise, wood frame construction – the predominant method of residential construction in Ontario. Therefore, they may not be applicable in all respects for other types of construction or assemblies. The Warranty Program will make its decisions based on the edition of the Guidelines that is in effect at the time a conciliation, warranty review or claim inspection is conducted. The effective date is indicated on both the cover of the Guidelines and on the bottom of each page. (The Guidelines will be reviewed periodically and expanded or updated to reflect legislative changes and/or changes in construction materials and technologies. To date there have been two editions of the Guidelines published. The first edition was effective on April 2, 2003 and the second edition was effective December 1, 2003.) Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 9
  • 11. Introduction SCOPE OF THE CONSTRUCTION PERFORMANCE GUIDELINES The Construction Performance Guidelines should be interpreted with common sense. They deal only with the most frequent and typical items of concern to homeowners. The Guidelines describe the minimum acceptable performance or condition that homeowners should expect and builders must meet to satisfy the requirements of the warranties described in the Ontario New Home Warranties Plan Act (“the Act”). Construction is not an exact science and generally, the materials used have natural properties and faults that must be considered when applying the Construction Performance Guidelines. For example: • Colours of all materials will be as close to samples as possible, but may not be identical to samples due to variances among manufacturers or differences in the manufacturing process; • Wood grains and colours may not necessarily match in all cases; • Shrinkage of natural materials may result in squeaks and creaks. Some items refer to specific dimensions to determine what is acceptable. These dimensions are used to evaluate the identified conditions. If the variation is minor, the Warranty Program may consider whether the variation significantly affects the performance of the item in determining whether the particular guideline has been met. SCOPE OF WARRANTY RESPONSIBILITIES Typically there may be a number of parties involved in a residential construction warranty issue in Ontario. The general responsibilities of the main parties are outlined below: The Homeowner 1: Before signing an Agreement of Purchase and Sale or construction contract, the prospective homeowner should carefully review the document to ensure that it expressly includes all the features agreed upon or to be selected during construction. Before signing a contract, the homeowner should seek legal advice, particularly if any aspect of the contract is unclear. Homeowners also have certain pre- and post-possession responsibilities to fulfill in order to preserve and exercise their statutory warranty rights. These responsibilities are briefly outlined in the section titled “Incomplete, Missing or Damaged Items” in this Introduction, and are explained in more detail in the Homeowner Information Package2. 1 The term owner is defined in the Ontario New Home Warranties Plan Act – see the definition in the “Terminology” section on pages 15-17. Throughout this document the term homeowner will be used to refer to owners. 2 The information contained in the Homeowner Information Package applies only to new freehold homes and condominium units with a date of possession on or after October 1, 2003. Construction Performance Guidelines Second Edition, effective December 1, 2003 10 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 12. Introduction Builder/Vendor3: The builder is responsible for honouring the first- and second-year warranties set out in the Act and Regulations. The builder may at times have to go back to the manufacturer to obtain a solution for a possible defect, which may delay the repair. For homes with a date of possession on or after October 1, 2003, builders must also follow the Warranty Service Rules, which are explained in detail in Builder Bulletin #42. The Ontario New Home Warranty Program: The Warranty Program is responsible for administering the Ontario New Home Warranties Plan Act. As part of this responsibility, the Warranty Program makes decisions when builders and homeowners disagree about an item covered under the statutory warranties. The Warranty Program also guarantees builders’ statutory warranties, and provides extended major structural defect coverage for years three through seven after a home’s date of possession. STATUTORY WARRANTY COVERAGE Warranty coverage is set out in the Act and takes effect from the date a homeowner takes possession of a new home from the builder (the “date of possession”). It remains in effect even if the home is sold or otherwise transferred before the end of the warranty period. There are three types of statutory warranty protection or coverages, including: The One-Year Warranty – A builder warrants that, for one year from the date of possession, the home: • is free from defects in work and materials; • is fit to live in, and; • meets Ontario Building Code requirements. Builders should provide homeowners with all warranties provided by manufacturers, suppliers and subcontractors that may extend beyond the first year. Homeowners must make claims on these extended warranties directly to the manufacturer or distributor. A builder is also required to provide a warranty against delayed closings (or delayed occupancy for condominium units) that occur without prescribed notice, and the homeowner may make a claim under this warranty within one year after the date of possession. For more information on delayed closings, homeowners should refer to the Homeowner Information Package or visit the Warranty Program Web site at www.newhome.on.ca 3 The terms builder and vendor are defined in the Ontario New Home Warranties Plan Act – see the definitions included in the “Terminology” section on pages 15-17. Throughout this document the term builder will be used to refer to builders and vendors. Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 11
  • 13. Introduction The Two-Year Warranty – A builder warrants that, for two years from the date of possession, the home is free from: • Water penetration through the basement or foundation walls; • Defects in materials or work (including windows, doors and caulking) that result in water penetration into the building envelope; • Defects in materials and work in the electrical, plumbing and heating delivery and distribution systems; • Defects in materials and work which result in detachment, displacement or deterioration of exterior cladding (such as brickwork, aluminum or vinyl siding); • Violations of Ontario Building Code regulations under which the Building Permit was issued, affecting health and safety, including, but not limited to, fire safety, insulation, air and vapour barriers, ventilation, heating and structural adequacy; • Major structural defects. For a definition of “major structural defect”, see the section entitled “Terminology”. Seven-Year Major Structural Defect4 Coverage – In addition to the builder’s two-year warranty against major structural defects, the Warranty Program provides extended coverage for major structural defects in years three through seven. CONDITIONS NOT COVERED UNDER WARRANTY It is important for homeowners to note what is not covered by the statutory warranty. The Act sets out the following exclusions from warranty coverage: • Defects in materials, design and work supplied by the homeowner; • Secondary damage caused by defects under warranty, such as property damage and personal injury; • Normal wear and tear; • Normal shrinkage of materials caused by drying after construction; • Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation or proper operation of moisture-producing devices such as humidifiers; • Damage caused by the homeowner or visitors; • Alterations, deletions or additions made by the homeowner; • Settling of land around the building or along utility lines, other than beneath the footings of the building; • Damage resulting from acts of God; • Contractual warranties which lie outside the Ontario New Home Warranties Plan Act; 4 The term “major structural defect” is defined in Regulation 892, Section 1, made under the Ontario New Home Warranties Plan Act, – see the definitions included in the “Terminology” section on pages 15-17. Construction Performance Guidelines Second Edition, effective December 1, 2003 12 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 14. Introduction • Damage caused by insects or rodents, except where construction does not meet specifications of the Ontario Building Code; • Damage caused by municipal services or other utilities; • Surface defects in work and materials specified and accepted in writing by the homeowner at the date of possession. Warranty is also not applicable to: • Temporary or seasonal homes not built on permanent foundations and not insulated sufficiently to enable year-round living (i.e., cottages); • Homes built on pre-existing footings or foundations; • Homes that have been lived in or rented prior to sale; • Homes built in converted buildings; • Homes purchased from a receiver or trustee may not have warranty coverage in certain circumstances. If there is any conflict between this publication and the Act or Regulations, the latter prevail. The Warranty Program assumes no liability for any error or omission in this publication. INCOMPLETE, MISSING OR DAMAGED ITEMS – Pre-Delivery Inspection (PDI) A pre-delivery inspection (PDI) is conducted by the builder and the prospective homeowner (or the homeowner’s designate), on or before the date of possession. The PDI provides an important opportunity for the prospective homeowner to observe and record any items in the home that are incomplete, missing, damaged or non-operational. If the item is covered by a statutory warranty, the builder must repair the damaged or non-operational item, or install the missing or incomplete item. For homes with a date of possession before October 1, 2003, these items should be recorded on the Certificate of Completion and Possession (CCP) or in an attachment to the CCP. For homes with a date of possession on or after October 1, 2003, these items must be recorded on a Pre-Delivery Inspection Form (PDI Form) that has been approved by the Warranty Program. Listing an incomplete, missing, damaged or non-operational item on the CCP or the PDI Form will provide a formal record of the existence of the condition before the homeowner took possession. Without this record it may be impossible for the Warranty Program to determine whether the item is covered under warranty if a dispute arises as it may not be clear who caused the damage or malfunction in question or whether an item was missing before the date of possession. Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 13
  • 15. Introduction After the PDI, any PDI items not rectified by the builder and any new defects that have emerged should be reported in writing to both the builder and the Warranty Program within the applicable warranty period. For homes with a date of possession on or after October 1, 2003, the homeowner must report these items on standard Warranty Service Request Forms and submit them within the time periods set out in the Warranty Services Rules. For more information on the PDI and the Warranty Service Rules, homeowners should refer to the Homeowner Information Package. HOW TO USE THIS DOCUMENT The Construction Performance Guidelines are divided into articles based on construction sequence. The information is organized according to types of conditions, and in each case, the following is described: • Condition: A brief description of the identified situation. • What is acceptable: The acceptable performance standard of the condition. • Which warranty applies: The statutory warranty that applies and any exclusions. • Required action: A description of the action that the builder or homeowner must take to rectify the identified condition. • Remarks: Information to help users understand and solve the problem. Construction Performance Guidelines Second Edition, effective December 1, 2003 14 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 16. Introduction TERMINOLOGY Builder The person or entity that undertakes the performance of all work and supply of all the materials necessary to construct a completed home whether for the purpose of sale by the person or entity or under a contract with a vendor or homeowner. In these Guidelines, the term “builder” is used to refer to both vendors and builders. Building Envelope The wall and roof assemblies that contain the building space, and include all those elements of the assembly that contribute to the separation of the outdoor and indoor environments so that the indoor environment can be controlled within acceptable limits. Contract The Agreement of Purchase and Sale between the builder and homeowner, or the construction contract between the builder and homeowner who owns the land. Date of Possession The date on which the home is completed by the builder for possession by the first homeowner. Delivery and Distribution Systems Include all wires, conduits, pipes, junctions, switches, receptacles and seals, but does not include appliances (except furnaces), fittings and fixtures. Exterior Cladding All exterior wall coverings, including siding and above-grade masonry (for example, concrete, bricks, or stone) as required and detailed in the relevant sections of the Ontario Building Code under which the Building Permit was issued. Home Includes self-contained one-family dwellings, whether attached or detached; buildings consisting of two or less self-contained one-family dwellings under common ownership; or a condominium dwelling unit, including the common elements. Also includes any structure used in conjunction with the home, but does not include a building built and sold for temporary occupancy or for seasonal purposes. Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 15
  • 17. Introduction Homeowner The person who first acquires the home from a builder for occupancy, and the person’s successor in title. Major Structural Defect Any defect in work or materials: a) that results in failure of the load-bearing portion of any building, or materially and adversely affects its load-bearing function, or b) that materially and adversely affects the use of such building for the purpose for which it was intended, Including: • significant damage due to certain types of soil movement, • major cracks in basement walls, • collapse or serious distortion of joints or roof structure and chemical failure of materials. Excluding any defect attributable in whole or in part to: • flood damage, • dampness not arising from failure of a load-bearing portion of the building, • damage to drains or services, • damage to finishes, and • damage arising from acts of God, acts of the homeowners and their tenants, licensees and invitees, acts of civil and military authorities, acts of war, riot, insurrection or civil commotion and malicious damage. Normal Typical, usual, ordinary or reasonably expected. PDI Pre-Delivery Inspection of the home, which is conducted by the builder together with the purchaser or their designate. Properly painted surface Uniform in appearance, colour and sheen, free of foreign material, lumps, skins, runs, sags, insufficient coverage, drips, spatter, spills and over spray. Construction Performance Guidelines Second Edition, effective December 1, 2003 16 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 18. Introduction Repair Activity to be undertaken by the builder as referred to under Action for conditions included in the Construction Performance Guidelines. The method of repair may involve restoration, alteration, or partial or full replacement of materials or equipment. The builder must choose a repair method that will satisfy the acceptable performance/condition specified in the applicable guideline. Generally, where repairs are necessary, colour and/or texture may not match exactly the surrounding original material. Smooth An even surface that is free from bumps, projections, foreign material, etc. Specified plane A flat, invisible line between two points on the surface of a wall, ceiling or floor which defines the intended flat surface. The points shall be located as far apart as possible, e.g. opposite sides of a room or opposite ends of a wall. Such a plane of reference is used to measure the variation between the specified plane and the actual surface. See Appendix A4 “Measuring Variation from the Specified Plane Using a Plane of Reference”. Vendor The person or entity who sells on its own behalf a home not previously occupied to a homeowner. Visible Easily seen when viewed from a position that is normal to the use of the room or area – e.g., hallway – standing position; living room – standing or sitting. Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 17
  • 19. Foundation/Basement 1.1 CONDITION EFFLORESCENCE IS PRESENT ON CONCRETE OR MASONRY SURFACES Acceptable Performance/Condition Efflorescence may occur on concrete and masonry surfaces. Warranty None. Action The builder is not required to take any action. Remarks Efflorescence is the formation of a white crystalline deposit on the surface of concrete and masonry when moisture evaporates from the surface. It is an indication that moisture is moving through the material to the surface, which is a normal condition. Efflorescence can be removed with a stiff brush and water. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 18
  • 20. Foundation/Basement 1.2 CONDITION INTERIOR CONCRETE SURFACES ARE POWDERY Acceptable Performance/Condition Concrete surfaces shall be sufficiently hard to prevent powdering which results in exposure of the aggregate. Warranty One-Year – Work and Materials • Surface deterioration due to owner-applied substances is excluded from the statutory warranty. Action Where powdering occurs exposing the aggregate the concrete surface shall be repaired to provide a hardened surface. Remarks Some dusting of the concrete surface may normally occur; however, where the aggregate becomes exposed the condition is considered excessive. The colour and texture of a repaired area may not match the surrounding concrete. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 19 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 21. Foundation/Basement 1.3 CONDITION CONCRETE SURFACE IS FLAKING OFF OR “SCALING” Acceptable Performance/Condition Concrete surfaces shall not disintegrate to the extent that the aggregate is exposed under normal conditions of weathering and use. Warranty One-Year – Work and Materials • Surface deterioration due to owner-applied substances, improper maintenance, or normal wear and tear is excluded from the statutory warranty. Action Where defective installation or product is determined the concrete surface shall be repaired. Remarks Scaling most often results from salts and de-icers being applied to the concrete surface, e.g. either intentionally for ice melting or unintentionally from road slush deposits. Cleaning salt deposits off concrete surfaces is normal home maintenance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 20
  • 22. Foundation/Basement 1.4 CONDITION CONCRETE FLOOR WITHOUT BUILDER-APPLIED FINISHED FLOORING IN BASEMENT IS UNEVEN Acceptable Performance/Condition Within a 3 m specified plane, concrete floors shall not have bumps or depressions exceeding ±12 mm. Sloped areas providing drainage to floor drains are not considered to be uneven. Warranty One-Year – Work and Materials Action Uneven floors exceeding the acceptable condition shall be repaired. Remarks Repairs may include grinding or applying a topping. The colour and texture of a repaired area may not match the surrounding concrete. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 21 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 23. Foundation/Basement 1.5 CONDITION CONCRETE BASEMENT FLOOR IS CRACKED Acceptable Performance/Condition Cracks resulting from normal shrinkage are acceptable; cracks in excess of 6 mm in width are not acceptable. Warranty One-Year – Work and Materials • Cracks resulting from normal shrinkage of materials caused by drying after construction are excluded from the statutory warranty. Action Cracks in excess of the acceptable condition shall be repaired. Remarks Concrete floors naturally crack during curing due to shrinkage. Actual crack widths shall be determined using a wire feeler gauge* inserted inside the crack. Where repairs are necessary, colour and/or texture may not match the surrounding concrete. * Because it is of a manufactured, set size, an Allen Wrench/Key may be used as a wire feeler gauge. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 22
  • 24. Foundation/Basement 1.6 CONDITION CONCRETE FLOOR SLAB-ON-GROUND HAS SETTLED IN A FINISHED AREA Acceptable Performance/Condition At the perimeter of rooms, concrete floor slabs shall not settle more than 12 mm from their original position. Warranty One-Year – Work and Materials Action Slabs that settle more than the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 23 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 25. Foundation/Basement 1.7 CONDITION NO REINFORCING IN BASEMENT CONCRETE SLAB Acceptable Performance/Condition Unless the slab is specifically intended and designed to be a structural slab, reinforcing or mesh is not required. Warranty One-Year – Work and Materials Seven-Year – Major Structural Defect Action Where a structural slab is not reinforced as required by the design, repairs shall be made; otherwise no action is required. Remarks Concrete slabs in basements shall conform to Section 9.16 of the Ontario Building Code. Reinforcing of concrete slabs is not usually necessary unless unusual design or construction conditions are encountered. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 24
  • 26. Foundation/Basement 1.8 CONDITION CONCRETE BLOCK FOUNDATION WALL IS CRACKED Acceptable Performance/Condition Cracks resulting from normal shrinkage are acceptable; cracks in excess of 6 mm in width are not acceptable. Warranty One-Year – Work and Materials • Cracks resulting from normal shrinkage of materials caused by drying after construction are excluded from the statutory warranty. Action Cracks in excess of the acceptable condition shall be repaired. Remarks Where crack width exceeds the acceptable condition, or where lateral or vertical movement is evident, further investigation may be required. The colour and texture of a repaired area may not match the surrounding concrete. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 25 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 27. Foundation/Basement 1.9 CONDITION PARGING (NOT BRUSH COATING) IS FALLING OFF ABOVE GRADE Acceptable Performance/Condition Hairline cracks are normal in parged surfaces; parging that is separating from the concrete block base is not acceptable. Warranty One-Year – Work and Materials • Cracks resulting from normal shrinkage of materials due to normal drying after construction are not covered by the statutory warranty. Action Parging not meeting the acceptable condition shall be repaired. Remarks The Ontario Building Code only requires parging (a cement-based layer) on concrete block foundation walls below grade. Brush coating, however, is only a cosmetic application over poured concrete foundation walls and is not covered by the statutory warranty. Slight variation in the colour or texture of repaired areas is acceptable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 26
  • 28. Foundation/Basement 1.10 CONDITION EXPOSED CAST-IN-PLACE CONCRETE FOUNDATION WALL HAS HOLES IN THE SURFACE Acceptable Performance/Condition The exterior portion of foundation walls exposed to view above grade shall have no holes (including “honeycombing”) larger than 50 mm in diameter or 25 mm deep. Warranty One-Year – Work and Materials Action Walls with holes exceeding the acceptable condition shall be repaired. Remarks It is impossible to completely eliminate all surface voids. At the builder’s discretion a brush coat may be applied. The colour and texture of a repaired area may not match the surrounding concrete. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 27 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 29. Foundation/Basement 1.11 CONDITION CAST-IN-PLACE CONCRETE FOUNDATION WALL IS CRACKED Acceptable Performance/Condition Cracks resulting from normal shrinkage are acceptable; cracks in excess of 6 mm in width are not acceptable. Warranty One-Year – Work and Materials • Cracks resulting from normal shrinkage of materials caused by drying after construction are excluded from the statutory warranty. Action Walls with cracks exceeding the acceptable condition shall be repaired. Remarks Concrete walls naturally crack during curing due to shrinkage. Where lateral or vertical movement is evident, further investigation may be required. The colour and texture of a repaired area may not match the surrounding concrete. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 28
  • 30. Foundation/Basement 1.12 CONDITION CONDENSATION IN CRAWL SPACE Acceptable Performance/Condition Condensation shall not accumulate on crawl space interior surfaces. Warranty Two-Year – Ontario Building Code Health & Safety Violations • Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty. Action Adequate ventilation equipment shall be installed in accordance with the Ontario Building Code. Remarks Crawl spaces shall be ventilated in accordance with the Ontario Building Code. Crawl space ventilation requires careful management by the homeowner to maintain acceptable moisture levels. Typical temporary conditions that may contribute to condensation are: a) at night in unheated crawl spaces, air entering the crawl space gradually cools the interior surfaces of the space. When outdoor temperatures rise the next day moisture picked up by the warm air is carried into the crawl space and condenses on the cool surfaces. b) at night in heated crawl spaces, outside air may rapidly cool foundation walls and provide a cool surface on which moisture in the crawl space can condense. c) if the house is left unheated in the winter, the floors and walls may provide cold surfaces on which moisture in the warmer crawl space may condense. d) stored materials obstruct ventilation airflow. These conditions may not be covered under the statutory warranty. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 29 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 31. Foundation/Basement 1.13 CONDITION BASEMENT WALL OR FLOOR IS DAMP Acceptable Performance/Condition Dampness on wall or floor surfaces caused by capillary transport or condensation of water vapour may occur. Only actual water penetration through an opening in the wall or floor may be covered by the statutory warranty. See sections 1.14 “Foundation Wall Leaks” and 1.15 “Water Leakage Through Basement Floor Slab”. Warranty None. • Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty. Action No action by the builder is required. Remarks Condensation can occur during peak seasonal weather patterns. The homeowner should immediately reduce the moisture levels to prevent harm to property. Dampness can be reduced by using a dehumidifier or by increasing the amount of ventilation to the area. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 30
  • 32. Foundation/Basement 1.14 CONDITION FOUNDATION WALL LEAKS Acceptable Performance/Condition Foundation walls shall allow no water penetration. Warranty Two-Year – Basement Water Penetration • Water leakage resulting from improper maintenance, exterior grade alterations made by the homeowner, an act of God or failure of municipal services or other utilities is excluded from the statutory warranty. Secondary damage to property or any personal injury resulting from the water penetration is also excluded from the statutory warranty. Action Water penetration through the basement or foundation shall be repaired. Remarks Only actual water penetration through the foundation is warranted; dampness caused by condensation or other causes is not considered to be water penetration and is not covered by the statutory warranty. The homeowner must take immediate steps to prevent damage to their property and report any losses to their home insurance provider. See Appendix A5 “How to Conduct a Water Test” for more information. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 31 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 33. Foundation/Basement 1.15 CONDITION WATER LEAKAGE THROUGH BASEMENT FLOOR SLAB Acceptable Performance/Condition Basement floor slabs shall allow no water penetration. Warranty Two-Year – Basement Water Penetration • Water leakage resulting from improper maintenance, exterior grade alterations made by the homeowner, an act of God or failure of municipal services or other utilities is excluded from the statutory warranty. Secondary damage to property or any personal injury resulting from the water penetration is also excluded from the statutory warranty. Action Defects resulting in water penetration through the basement floor slab shall be repaired. Subsurface investigation may be required. Remarks Only actual water leakage through the floor slab is warranted; dampness or condensation is not considered a warranted condition. The homeowner must take immediate steps to prevent damage to their property and report any losses to their home insurance provider. A thorough site investigation prior to construction and during excavation will assist in determining whether groundwater levels may adversely affect the use of the building. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 32
  • 34. Floor Framing 2.1 CONDITION WOOD BEAM OR POST IS SPLIT Acceptable Performance/Condition Load-bearing wood beams and posts that have splits and checks due to normal drying are acceptable if the beams and posts have been sized according to the Ontario Building Code and no structural deficiency exists. Where the wood beam or post is also intended to be decorative, splits and checks resulting from normal shrinkage are acceptable. Warranty One-Year – Work and Materials Seven-Year – Major Structural Defect • Splits and checks resulting from normal shrinkage caused by drying after construction are excluded from the statutory warranty. Action Splits and checks not meeting the acceptable performance shall be repaired. Remarks Wood beams and posts are timbers that are solid-sawn and at least 114 mm (41/2") in their smallest dimension. Some characteristics of drying wood, such as splitting and checking, are beyond the control of the builder and cannot be prevented. Splitting and checking are primarily aesthetic concerns rather than structural problems. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 33 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 35. Floor Framing 2.2 CONDITION WOOD BEAM OR POST IS CUPPED Acceptable Performance/Condition Load-bearing wood beams and posts that are cupped due to normal drying are acceptable if the beams and posts have been sized according to the Ontario Building Code and no structural deficiency exists. Warranty One-Year – Work and Materials Seven-Year – Major Structural Defect • Cups resulting from normal shrinkage caused by drying after construction are excluded from the statutory warranty. Action Cupped beams and posts not meeting the acceptable condition shall be repaired. Remarks Wood beams and posts are timbers that are at least 114 mm (41/2") in their smallest dimension. A characteristic of drying wood such as cupping is beyond the control of the builder and cannot be prevented. Cupping is primarily an aesthetic concern rather than a structural problem. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 34
  • 36. Floor Framing 2.3 CONDITION STRUCTURAL COLUMN IN UNFINISHED BASEMENT IS OUT OF PLUMB Acceptable Performance/Condition Structural columns (wood, masonry, concrete or steel) in an unfinished basement shall not be out of plumb more than 25 mm in 2,400 mm. Warranty One-Year – Work and Materials Seven-Year – Major Structural Defect Action Structural columns out of plumb more than the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 35 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 37. Floor Framing 2.4 CONDITION FLOOR FRAMING DAMAGED BY WEATHER DURING CONSTRUCTION Acceptable Performance/Condition The joists and subfloor shall be sound and free from damage caused by weathering and must provide a suitable base for finished flooring. Warranty One-Year – Work and Materials Seven-Year – Major Structural Defect Action Joists and subfloors damaged by weathering to the extent that they cannot carry the anticipated loads or are made unsuitable for finished flooring shall be repaired. Remarks Materials that can be significantly damaged by weather should be protected during storage and construction. Composite panels such as oriented strandboard and plywood used for subfloors and webs of manufactured joists require more protection than solid-sawn lumber and can swell or delaminate if saturated over lengthy periods. Discolouration alone does not necessarily indicate a warrantable condition. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 36
  • 38. Floor Framing 2.5 CONDITION LOOSE SUBFLOOR Acceptable Performance/Condition Subfloors shall not become loose and no movement shall be felt underfoot under normal loading conditions. Subfloors shall be fastened in accordance with the Ontario Building Code. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violations • Normal shrinkage of materials caused by drying after construction is excluded from the statutory warranty. Action Where movement of the subfloor is confirmed, repairs shall be made. Remarks Delamination of plywood subfloors is considered a warranted defect in material. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 37 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 39. Floor Framing 2.6 CONDITION FLOOR SQUEAKS Acceptable Performance/Condition Floors shall be free from squeaks caused by movement in the floor system connections under normal loading conditions. Warranty One-Year – Work and Materials • Squeaks resulting from normal shrinkage of materials caused by drying after construction are excluded from the statutory warranty. Action Loose connections causing floor squeaks shall be repaired. Remarks Extended low-humidity indoor environments can cause excessive shrinkage in the wood resulting in loose floor connections. The homeowner must maintain indoor humidity levels to prevent excessive drying of materials. A squeak-free floor may not be attainable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 38
  • 40. Floor Framing 2.7 CONDITION FINISHED FLOOR ABOVE GRADE IS OUT OF LEVEL Acceptable Performance/Condition Within a room, floors shall appear level when viewed from a normal viewing position. Where a floor framed with dimensional lumber appears sloped, a maximum tolerance ratio of 25 mm in 3600 mm applies, when measured between the opposite walls or defined limits of the room or area. Warranty One-Year – Work and Materials • Minor slope variance caused by normal shrinkage of materials due to drying after construction is excluded from the statutory warranty. Action Floors in rooms sloped greater than the acceptable performance shall be repaired. Remarks This item refers to the entire floor surface in rooms. Where a floor is framed with an engineered floor system, minor slope variations caused by the required camber in the long-spanned joists supporting the floor are excluded from the statutory warranty. For uneven areas in floors see section 12.2 “Floor is Uneven”. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 39 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 41. Floor Framing 2.8 CONDITION SPRINGINESS, BOUNCE, VISIBLE SAG WHEN LOADED, OR SHAKING IS OBSERVED IN THE FLOOR Acceptable Performance/Condition These conditions are acceptable when all structural members including beams and joists are sized, installed and fastened in accordance with the Ontario Building Code. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violations Action Floors not meeting the performance condition shall be repaired. Remarks Long-spanned floor joists will normally move more than short-spanned joists under design loads. The conditions can be assessed by determining the performance under loading conditions; measuring the length of the structural member and dividing by 360 will give the maximum deflection allowed. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 40
  • 42. Wall Framing 3.1 CONDITION WALL IS OUT OF PLUMB Acceptable Performance/Condition Where the condition is visible from a normal viewing position, walls shall not be out of plumb more than 25 mm in 2,400 mm vertical measurement. Warranty One-Year – Work and Materials Action Walls not meeting the acceptable condition shall be repaired. Remarks It is reasonable to expect minor variation from plumb. Fitment of furnishings is not considered to be the test for plumb. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 41 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 43. Wall Framing 3.2 CONDITION WALL IS BOWED Acceptable Performance/Condition On the interior of a home, where bowed framing causes local distortion, the variation shall not be more than ±20 mm from the specified plane. Warranty One-Year – Work and Materials • Distortion due to shrinkage caused by normal drying after construction is not covered by the statutory warranty. Action Bows exceeding the acceptable condition shall be repaired. Remarks It is reasonable to expect walls to have variances in their finished surface. Varying light conditions can exaggerate minor variations in appearance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 42
  • 44. Wall Framing 3.3 CONDITION MALFUNCTION OF WINDOWS Acceptable Performance/Condition Windows shall be installed to operate with reasonable ease. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance, or alterations, deletions or additions made by the homeowner is not covered by the statutory warranty. Action Windows not meeting the acceptable performance shall be repaired. Remarks Confirm proper operation of windows during the PDI and record any malfunction on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Window operation varies with different window designs. Windows require regular maintenance for optimum performance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 43 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 45. Wall Framing 3.4 CONDITION WINDOW GLASS AND/OR SCREEN IS DAMAGED Acceptable Performance/Condition Window glass and screens shall be free from damage at the time of the PDI. Warranty One-Year – Work and Materials Action Damaged window glass and screens reported on the PDI Form shall be repaired. If not noted, the homeowner must establish that the damage was caused by the builder. Remarks Note any damaged windows or damaged/missing screens on the PDI Form. If not noted, it will be difficult to establish that the damage was caused by the builder. If you cannot assess damage because the surface of the windows has been obscured from view, this should also be noted on the PDI Form. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 44
  • 46. Wall Framing 3.5 CONDITION GLASS IS SCRATCHED Acceptable Performance/Condition Glass surfaces shall not have scratches visible from a distance of 1,500 mm at the time of the PDI. Warranty One-Year – Work and Materials • Damage due to improper maintenance and normal wear and tear is not covered by the statutory warranty. Action Scratched glass not meeting the acceptable condition and reported on the PDI Form shall be repaired. If not noted, the homeowner must establish that the damage was caused by the builder. Remarks Note any damage on windows on the PDI Form. If not noted, it will be difficult to establish that the damage was caused by the builder. If you cannot assess damage because the surface of the windows has been obscured from view, this should also be noted on the PDI Form. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 45 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 47. Wall Framing 3.6 CONDITION GLASS IS CRACKED Acceptable Performance/Condition Windows shall be installed so that the glass does not crack due to unusual stress caused by movement or settlement of the building frame. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear is not covered by the statutory warranty. Action Windows with glass showing stress cracks shall be repaired. Remarks Stress cracks occur across corners of glass as a result of pressure being applied to the edge of the glass. If there is evidence of an impact, and the condition was not recorded on the PDI Form, it will be difficult to establish that the damage was caused by the builder. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 46
  • 48. Wall Framing 3.7 CONDITION WINDOW UNIT LEAKS DURING RAIN Acceptable Performance/Condition Windows shall not allow water penetration under normal weather conditions when properly closed. Warranty One-Year – Work and Materials Two-Year – Building Envelope Water Penetration • Damage caused by improper maintenance or an act of God is excluded from the statutory warranty. Action Defective windows that leak shall be repaired or replaced. Remarks The homeowner must ensure operable windows are properly closed, weatherstripping and caulking is maintained and drain ports are not obstructed. The window manufacturer may provide extended warranty coverage. See Appendix A5 “How to Conduct a Water Test” for more information. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 47 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 49. Wall Framing 3.8 CONDITION CONDENSATION FORMING BETWEEN INSULATING (FACTORY SEALED) GLASS UNIT Acceptable Performance/Condition Insulating glass units shall be free from condensation between the panes. Warranty One-Year – Work and Materials Action Insulating glass units with condensation between the panes shall be replaced. Remarks Condensation between panes indicates the airtight seal around the edge of the glass is broken. An extended warranty may be available through the window manufacturer. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 48
  • 50. Wall Framing 3.9 CONDITION EXTERIOR DOOR IS WARPED Acceptable Performance/Condition Doors shall not warp to the extent that they become inoperable or cease to be weather resistant. Doors between a home and an attached garage must be maintained to be gas-proof. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violation for doors requiring gas-proofing. • Damage resulting from improper maintenance or alterations, deletions or additions made by the homeowner is not covered by the statutory warranty. Action Doors not meeting the acceptable performance shall be replaced. Remarks Confirm proper operation of exterior doors during the PDI and record any malfunction on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Exterior doors can warp to some degree due to temperature differential between inside and outside surfaces. Garage doors between the garage space and the outdoors are not required to be weatherstripped. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 49 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 51. Wall Framing 3.10 CONDITION EXTERIOR METAL DOOR IS DENTED Acceptable Performance/Condition Exterior doors shall not be dented at the time of the PDI. Warranty One-Year – Work and Materials Action Dented exterior metal doors noted on the PDI Form shall be repaired. If not noted, the homeowner must establish that the damage was caused by the builder. Remarks Identify damaged doors on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Filling the dent is an acceptable repair (e.g. spot putty). Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 50
  • 52. Wall Framing 3.11 CONDITION SHRINKAGE OF INSERTED PANELS SHOWS RAW WOOD EDGES ON EXTERIOR WOOD DOORS Acceptable Performance/Condition Wooden panels will shrink and expand because of temperature and/or humidity changes, and may expose unpainted surfaces; this is acceptable. However, gaps between the edge of an inserted panel and the rest of the door caused by shrinkage are not normal and not acceptable. Warranty One-Year – Work and Materials • Normal shrinkage of materials caused by drying after construction is not covered by the statutory warranty. Action Doors not meeting the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 51 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 53. Wall Framing 3.12 CONDITION CRACKS AND SPLITS IN EXTERIOR WOOD DOORS Acceptable Performance/Condition Cracks penetrating through the door are not acceptable. Warranty One-Year – Work and Materials Action Doors not meeting the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 52
  • 54. Wall Framing 3.13 CONDITION EXTERIOR DOOR STICKS Acceptable Performance/Condition Exterior doors and their hardware shall be installed to operate with minimal binding taking into account the weatherstripping seal and seasonal periods of high humidity. Warranty One-Year – Work and Materials • Alterations, deletions and additions made by the homeowner are not covered by the statutory warranty. Action Doors and hardware not meeting the acceptable performance shall be repaired. Remarks Confirm proper operation of exterior doors during the PDI and record any malfunction on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Exterior doors can warp to some degree because of the difference in the temperature between inside and outside surfaces. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 53 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 55. Wall Framing 3.14 CONDITION EXTERIOR DOOR WILL NOT CLOSE COMPLETELY Acceptable Performance/Condition Exterior doors shall close completely and latch securely. Warranty One-Year – Work and Materials Action Doors not meeting the acceptable performance shall be repaired. Remarks Confirm proper operation of exterior doors during the PDI and record any malfunction on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Slight pressure may be required during latching to compress the weatherstripping. Exterior doors can warp to some degree because of the difference in the temperature between inside and outside surfaces. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 54
  • 56. Wall Framing 3.15 CONDITION PLASTIC MOULDING ON EXTERIOR DOOR IS DEFORMED Acceptable Performance/Condition The plastic mouldings on exterior doors shall not deform when the door is installed in accordance with the manufacturer’s installation instructions. Warranty One-Year – Work and Materials • Damage caused by improper maintenance or material, design or work supplied by the homeowner is not covered by the statutory warranty. Action Exterior doors not meeting the acceptable condition shall be repaired. Remarks Generally, exterior door manufacturers indicate storm doors are not to be installed over metal exterior doors. Heat buildup between a storm door and the exterior door can increase significantly, damaging any heat-susceptible parts such as plastic mouldings around a window insert or decorative surface-applied mouldings. The homeowner is also cautioned to follow manufacturer's recommendations on maintenance and painting the mouldings a dark colour, with or without the use of a storm door; dark-coloured moulding is likely to deform and should be avoided. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 55 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 57. Wall Framing 3.16 CONDITION EXTERIOR DOOR SWINGS OPEN OR CLOSED BY ITSELF Acceptable Performance/Condition Exterior doors shall be installed sufficiently plumb and square so they do not swing by themselves due to the force of gravity alone. Warranty One-Year – Work and Materials • Alterations, deletions or additions by the homeowner are not covered by the statutory warranty. Action Exterior doors not meeting the acceptable performance shall be repaired. Remarks Confirm proper operation of exterior doors during the PDI and record any malfunction on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Doors will swing open or closed by the force of gravity if the hinges are not aligned plumb. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 56
  • 58. Wall Framing 3.17 CONDITION EXTERIOR DOOR IS CROOKED IN THE FRAME Acceptable Performance/Condition Exterior doors must have a proper weather seal when closed. The weatherstripping must contact the perimeter of the door. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear or improper maintenance is not covered by the statutory warranty. Action Exterior doors not meeting the acceptable condition shall be repaired. Remarks Confirm proper operation of exterior doors during the PDI and record any malfunction on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Variance in the width of the gap between the door and the frame is acceptable unless the proper operation of the door is affected. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 57 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 59. Wall Framing 3.18 CONDITION EXTERIOR DOOR HARDWARE OR DECORATIVE METAL TRIM HAS DISCOLOURED Acceptable Performance/Condition Finishes on door hardware and fixtures may discolour. Warranty None. Action No action by the builder is required. Remarks Some hardware may have a coating to inhibit discolouration. Maintaining protective coatings or removing discolouration is part of effective home maintenance. Oxidation and environmental pollutants can accelerate discolouration. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 58
  • 60. Wall Framing 3.19 CONDITION SLIDING DOOR SCREEN WILL NOT STAY ON TRACK OR SLIDING DOOR DOES NOT ROLL SMOOTHLY Acceptable Performance/Condition Sliding doors and their screens shall move freely on their tracks and latch securely. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear or improper maintenance is not covered by the statutory warranty. Action Sliding doors and their screens not meeting the acceptable condition shall be repaired. Remarks Normal home maintenance for sliding doors and screens may involve adjustment from time to time and the tracks and hardware may need to be cleaned and lubricated. Confirm proper operation of the door and screen during the PDI and record any malfunction on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 59 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 61. Exterior Finishing 4.1 CONDITION WOOD OR HARDBOARD OR PANEL-TYPE SIDING IS BOWED OR WAVY Acceptable Performance/Condition Siding shall be installed to accommodate thermal movement and anticipated shrinkage of the structure to which it is attached. Siding shall be free from bows and waviness when installed in accordance with the manufacturer’s specifications. Where local distortion is caused by bowed framing, the deviation of the bow measured from the specified plane shall not exceed ±20 mm. Warranty Two-Year – Cladding Detachment, Displacement or Deterioration • Defects in materials, work or design supplied by the homeowner or damage resulting from improper maintenance are excluded from the statutory warranty. Action Bowed or wavy siding exceeding the acceptable condition shall be repaired. Remarks Siding that is intended to have paint and/or sealer requires regular inspection and maintenance to ensure continuity of the protective layer. Elevated moisture levels can cause wood or hardboard siding to bow. Varying lighting conditions can exaggerate minor variations in siding profile and texture. Minor waviness due to normal fluctuations in humidity is acceptable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 60
  • 62. Exterior Finishing 4.2 CONDITION WOOD OR HARDBOARD OR PANEL-TYPE SIDING – JOINTS NOT TIGHT Acceptable Performance/Condition Wood or hardboard or panel-type siding shall be installed in accordance with the manufacturer’s specifications and the Ontario Building Code with gaps at joints to allow for expansion. Joints shall be suitably protected to prevent water penetration. Warranty One-Year – Work and Materials Two-Year – Building Envelope Water Penetration • Normal shrinkage of materials caused by drying after construction is excluded from the statutory warranty. • Defects in materials, work or design supplied by the homeowner and damage resulting from improper maintenance are excluded from the statutory warranty. Action Wood or hardboard or panel-type siding joints that do not meet the acceptable condition shall be repaired. Remarks Siding that is intended to have paint and/or sealer requires regular inspection and maintenance to ensure continuity of the protective layer. Wood, hardboard or panel-type siding can be expected to expand and contract with fluctuations in outdoor temperature and humidity; gaps in joints may be required to prevent buckling. Caulking or attaching battens over the joints are ways to protect the joints from water penetration. Where rain screen principles are used in the cladding design, the sealing may be behind the surface of the cladding. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 61 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 63. Exterior Finishing 4.3 CONDITION WOOD OR HARDBOARD OR PANEL-TYPE SIDING – FASTENERS ARE EXCESSIVELY COUNTERSUNK INTO FINISHED SURFACE Acceptable Performance/Condition Siding fasteners shall be installed in accordance with the manufacturer’s specifications, where applicable, and shall not expose hardboard siding fibre. Warranty One-Year – Work and Materials Action Siding with nails not meeting the acceptable condition shall be repaired. Remarks Nails that have been excessively countersunk detract from the overall appearance of the finished surface. This condition can lead to premature deterioration of the product by allowing water to accumulate in the holes left by the nailheads. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 62
  • 64. Exterior Finishing 4.4 CONDITION LAP SIDING (WOOD, HARDBOARD, VINYL, ETC.) IS NOT INSTALLED ON A STRAIGHT LINE Acceptable Performance/Condition Lap siding shall be installed with individual pieces in general, visible parallel alignment. Warranty One-Year – Work and Materials • Defects in materials, work or design supplied by the homeowner are excluded from the statutory warranty. Action Lap siding that does not meet the acceptable condition shall be repaired. Remarks With any type of siding or cladding such as lap siding that requires repetitive parallel alignment from one course to the next, the installer must make minor adjustments to keep the entire elevation in general alignment. Adjustments of this nature are normal. Wavy-edged siding is more tolerant of adjustments while maintaining an acceptable appearance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 63 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 65. Exterior Finishing 4.5 CONDITION TONGUE-AND-GROOVE WOOD SIDING HAS BUCKLED Acceptable Performance/Condition Tongue-and-groove wood siding shall be installed to prevent buckling and in accordance with manufacturer’s installation instructions, where applicable. Warranty Two-Year – Cladding Detachment, Displacement or Deterioration Action Siding that does not meet the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 64
  • 66. Exterior Finishing 4.6 CONDITION WOOD SIDING – FASTENER HAS STAINED SIDING Acceptable Performance/Condition Fasteners shall be corrosion resistant and compatible with the siding in accordance with the Ontario Building Code. Warranty One-Year – Work and Materials One-Year – Ontario Building Code Violations • Damage resulting from normal wear and tear or damage resulting from improper maintenance is excluded from the statutory warranty. Action Siding and fasteners not meeting the acceptable condition shall be repaired. Remarks Fasteners can be expected to weather, oxidize and discolour with exposure to the elements. Some localized staining of adjacent materials may occur. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 65 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 67. Exterior Finishing 4.7 CONDITION CEDAR SHAKES OR SHINGLES HAVE “BLED” THROUGH PAINT OR STAIN APPLIED BY BUILDER Acceptable Performance/Condition Where full-covering or opaque stains are used over cedar shakes or shingles, bleed-through of resins or extractives shall not be visible when viewed, without magnification, from a minimum perpendicular distance of 6 m under normal lighting conditions and from a normal viewing position. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear is excluded from the statutory warranty. Action Cedar shakes and shingles that do not meet the acceptable condition shall be repaired. Remarks Some bleed-through of knots or other naturally occurring features can be expected in cedar shakes over time. The reoccurrence of these features through full-covering or opaque stains may be dependent on the direction the roof faces and/or exposure to sunlight. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 66
  • 68. Exterior Finishing 4.8 CONDITION PLYWOOD OR VENEER SIDING HAS DELAMINATED Acceptable Performance/Condition Plywood or veneer siding shall not delaminate when installed in accordance with the manufacturer’s installation instructions. Warranty Two-Year – Cladding Detachment, Displacement or Deterioration • Damage resulting from normal wear and tear is excluded from the statutory warranty. Action Plywood/veneer siding that does not meet the acceptable condition shall be repaired. Remarks Siding that is intended to have paint and/or sealer requires regular inspection and maintenance to ensure continuity of the protective layer. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 67 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 69. Exterior Finishing 4.9 CONDITION ALUMINUM/VINYL SIDING IS BOWED OR WAVY Acceptable Performance/Condition Siding shall be installed to accommodate thermal movement and anticipated shrinkage of the structure to which it is attached. Siding shall be free from bows and waviness when installed in accordance with the manufacturer’s specifications. Where local distortion is caused by bowed framing the variation from the specified plane shall not exceed ±20 mm. Warranty One-Year – Work and Materials Two-Year – Cladding Detachment, Displacement or Deterioration Action Bowed or wavy siding exceeding the acceptable condition shall be repaired. Remarks Varying lighting conditions can exaggerate minor variations in siding profile, texture and colour. Minor waviness due to normal sheathing movements is acceptable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 68
  • 70. Exterior Finishing 4.10 CONDITION ALUMINUM OR VINYL SIDING – COLOUR IS FADED Acceptable Performance/Condition Aluminum or vinyl siding shall not fade or discolour in an uneven or random manner. Warranty Two-Year – Cladding Detachment, Displacement or Deterioration • Damage resulting from normal wear and tear is excluded from the statutory warranty. Action Aluminum or vinyl siding that does not meet the acceptable performance shall be repaired. Remarks Aluminum or vinyl siding may fade with time and exposure to sunlight. Areas of intense, direct sunlight exposure will tend to fade faster than other more shaded areas. Repaired areas shall match the existing material for colour and textures as closely as possible; variation between dye lots is acceptable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 69 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 71. Exterior Finishing 4.11 CONDITION ALUMINUM OR VINYL SIDING, TRIM OR ACCESSORY IS LOOSE Acceptable Performance/Condition Aluminum or vinyl siding and associated trim and accessories shall not become displaced or detached from the substrate and shall be installed in accordance with the manufacturer’s specifications. Warranty Two-Year – Cladding Detachment, Displacement or Deterioration • Damage resulting from an act of God is excluded from the statutory warranty. Action Aluminum or vinyl siding that does not meet the acceptable condition shall be repaired. Remarks Aluminum or vinyl siding is intentionally not installed tight to the substrate to allow for thermal movement; however, it should not displace or detach under normal weather conditions. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 70
  • 72. Exterior Finishing 4.12 CONDITION ALUMINUM OR VINYL SIDING TRIM AND ACCESSORIES – FASTENERS DON’T MATCH SIDING COLOUR Acceptable Performance/Condition Fasteners that are used to secure aluminum or vinyl siding or trim may not match the siding or trim colour due to manufacturing limitations. Warranty None. Action The builder is not required to take any action. Remarks Fasteners are generally made in fewer standard colours than siding products. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 71 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 73. Exterior Finishing 4.13 CONDITION ABOVE-GRADE MASONRY WALL OR VENEER CLADDING (INCLUDING MORTAR) IS CRACKED Acceptable Performance/Condition Cracks resulting from normal shrinkage are acceptable; crack width in excess of the ratio of 3 mm in 10 m is not acceptable. Warranty One-Year – Work and Materials • Cracks resulting from normal shrinkage of materials caused by drying after construction or normal wear and tear is excluded from the statutory warranty. Action Cracks in excess of the acceptable condition shall be repaired. Remarks Shrinkage during curing of the masonry is natural. Also, regular outdoor temperature fluctuations cause masonry cladding to expand and contract. The resulting thermal stress can also cause cracking; this is considered normal wear and tear. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 72
  • 74. Exterior Finishing 4.14 CONDITION CUT BRICKS ARE OF DIFFERENT THICKNESS IN RELATION TO ONE ANOTHER Acceptable Performance/Condition Cut bricks used in the same course shall appear uniform from a normal viewing position; the variance in thickness between two immediately adjacent bricks shall not exceed 8 mm. Warranty One-Year – Work and Materials Action Bricks not meeting the acceptable condition shall be repaired. Remarks Even with proper coursing bricks will need to be cut to fit site conditions. It is common that cut bricks may vary in thickness. Uncut bricks may also vary in thickness depending on the style selected (e.g. tumbled bricks). Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 73 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 75. Exterior Finishing 4.15 CONDITION HORIZONTAL MASONRY JOINT ALIGNMENT IS NOT UNIFORM Acceptable Performance/Condition Horizontal masonry joint work shall appear uniform when viewed from a distance of 6 m. Where the horizontal (bed) joint appears out of alignment, the variance shall not be more than ±12 mm from the specified plane. This does not apply to randomly sized masonry products. Warranty One-Year – Work and Materials Action Masonry with joints not meeting the acceptable condition shall be repaired. Remarks Dimensional variations of the courses are affected by the variations in the brick selected and the bond pattern. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 74
  • 76. Exterior Finishing 4.16 CONDITION MORTAR SPLATTERS AND STAINS ON EXTERIOR MASONRY Acceptable Performance/Condition Exterior masonry shall not have mortar splatters and stains detracting from the appearance of the finished wall when viewed from a distance of 6 m under natural lighting conditions when dry. Warranty One-Year – Work and Materials Action Masonry not meeting the acceptable condition shall be repaired. Remarks Care must be used in cleaning masonry. Although pressure washing and chemical cleaners are the normal way of cleaning masonry, they must be used properly and in accordance with brick manufacturer’s specifications. Professional brick tinting methods are acceptable to adjust colour. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 75 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 77. Exterior Finishing 4.17 CONDITION EFFLORESCENCE (WHITE POWDER) IS PRESENT ON MASONRY SURFACE Acceptable Performance/Condition Efflorescence commonly occurs on masonry surfaces and is normal. Localized concentrations of efflorescence visible from 6 m are not acceptable. Warranty One-Year – Work and Materials • Efflorescence resulting from additions, deletions or alterations made by the homeowner or improper maintenance is not covered by the statutory warranty. Action Localized concentrations of efflorescence visible from 6 m shall be investigated. If it is determined that a defect in work or material is the cause of the efflorescence, repairs shall be made. Remarks Efflorescence is the harmless deposit of mineral salts on the surface of masonry and occurs naturally due to the movement of moisture; it may diminish over time. Visibility varies with seasonal conditions. Dark-coloured bricks tend to exaggerate the appearance of efflorescence. Localized areas of efflorescence may be linked to abnormal sources of moisture. Salt and de-icers may also contribute to efflorescence. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 76
  • 78. Exterior Finishing 4.18 CONDITION DETERIORATING MASONRY Acceptable Performance/Condition Masonry shall be manufactured and installed to prevent premature deterioration. Warranty Two-Year – Cladding Detachment, Displacement or Deterioration • Damage resulting from normal wear and tear, improper maintenance or additions, alterations and deletions made by the homeowner is not covered by the statutory warranty. Action Masonry that is deteriorated, detached, or displaced shall be repaired. Remarks Durability is dependent on the type of masonry and the conditions that the masonry is exposed to (e.g. salt, soil). The colour/texture of repaired areas shall match the existing as closely as possible when dry. Variation in colour may be noticeable when wet. Where colour variation of the repaired area is visible under normal lighting and dry conditions from 6 m, the colour shall be adjusted. Professional brick tinting methods are acceptable to adjust colour. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 77 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 79. Exterior Finishing 4.19 CONDITION WATER LEAKAGE AT DOORS AND WINDOWS OR AT THE TOP OF THE FOUNDATION Acceptable Performance/Condition Openings in exterior walls such as windows and doors, and junctions between cladding materials, shall not allow water penetration. Warranty One-Year – Ontario Building Code Violations Two-Year – Building Envelope Water Penetration • Water penetration due to improper maintenance is excluded from the statutory warranty. Action Defects resulting in water penetration around windows, doors, and over the top of the foundation shall be repaired. Remarks Flashings must be installed above exterior wall openings and at the top of the foundation (masonry veneer) to direct water to the exterior. Perforations in flashing due to physical damage or chemical incompatibility, deterioration, improper termination and lack of weep holes in masonry veneer can allow water to drain to the interior. See Appendix A5 “How to Conduct a Water Test” for more information. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 78
  • 80. Exterior Finishing 4.20 CONDITION CLAY BRICKS ARE CHIPPED Acceptable Performance/Condition Clay brick veneer shall be installed in accordance with the Ontario Building Code. Installed clay bricks that are visible as part of the cladding shall not be chipped in excess of the limits described in Appendix A7 “Chipped Clay Bricks”. Warranty One-Year – Work and Materials One-Year – Ontario Building Code Violations • Damage resulting from normal wear and tear, improper maintenance or additions, alterations and deletions made by the homeowner is not covered by the statutory warranty. Action Brick veneer not meeting the acceptable condition shall be repaired. Remarks There are certain brick types that are designed to be tumbled or chipped in appearance. Professional brick tinting methods are acceptable to repair the appearance of chipped bricks. The colour/texture of repaired areas shall match the existing as closely as possible when dry. Variation in colour may be noticeable when wet. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 79 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 81. Exterior Finishing 4.21 CONDITION BRICKS ARE DIFFERENT COLOURS Acceptable Performance/Condition Brickwork may contain bricks from different dye lots, provided they are dispersed throughout the wall to produce a generally uniform appearance when viewed from 6 m under normal lighting conditions. Warranty One-Year – Work and Materials Action Where a generally uniform appearance is not achieved the wall shall be repaired. Remarks Uniform appearance includes colour and texture. Professional brick tinting methods are acceptable to adjust colour. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 80
  • 82. Exterior Finishing 4.22 CONDITION CRACKS IN EXTERIOR STUCCO WALL SURFACES Acceptable Performance/Condition Stucco that relies on face-sealing to shed water shall have no cracks or gaps that will allow water penetration. Stucco on a drained cladding system shall not have unintentional gaps or cracks visible from a distance of not less than 6 m. Warranty Two-Year – Cladding Detachment, Displacement or Deterioration • Damage resulting from improper maintenance is not covered by the statutory warranty. Action Stucco finish not meeting the acceptable condition shall be repaired. Remarks Stucco includes traditional Portland cement-based stucco as well as synthetic stucco whether forming part of an exterior insulation and finish system (EIFS) or not. Caulking and sealants require regular maintenance to ensure effectiveness. The colour or texture of repaired areas shall match the existing so as not to be visible from a distance of 6 m under normal lighting conditions. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 81 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 83. Exterior Finishing 4.23 CONDITION EXTERIOR STUCCO IS PEELING OR BUBBLING Acceptable Performance/Condition Stucco on exterior walls shall not separate from its base. Warranty Two-Year – Cladding Detachment, Displacement or Deterioration • Damage resulting from improper maintenance is not covered by the statutory warranty. Action Stucco not meeting the acceptable condition shall be repaired. Remarks Stucco separating from its base may indicate a problem with trapped moisture. Caulking and sealants require regular maintenance to ensure effectiveness. The colour or texture of repaired areas shall match the existing so as not to be visible from a distance of 6 m under normal lighting conditions. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 82
  • 84. Exterior Finishing 4.24 CONDITION UNSEALED GAPS BETWEEN DISSIMILAR CLADDING MATERIALS AND PENETRATIONS THROUGH CLADDING Acceptable Performance/Condition Gaps allowing water penetration into the building envelope shall be sealed in accordance with the Ontario Building Code. Warranty One-Year – Work and Materials One-Year – Ontario Building Code Violations Two-Year – Building Envelope Water Penetration Two-Year – Cladding Detachment, Displacement or Deterioration • Damage resulting from improper maintenance is not covered by the statutory warranty. Action Cladding not meeting the acceptable condition shall be repaired. Remarks Space between different cladding materials, and between penetrations is required to allow for movement but must be weathertight. Where rain screen principles are used in the cladding design, the sealing may be behind the surface of the cladding. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 83 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 85. Exterior Finishing 4.25 CONDITION EXTERIOR WOOD TRIM IS SPLIT Acceptable Performance/Condition Exterior wood trim may split; cracks visible from 6 m under normal lighting conditions, or cracks resulting in displacement or detachment, are not acceptable. Warranty One-Year – Work and Materials Two-Year – Cladding Detachment, Displacement or Deterioration • Cracks resulting from normal shrinkage of materials caused by drying after construction, or normal wear and tear are not covered by the statutory warranty. Action Trim not meeting the acceptable condition shall be repaired. Remarks Some manufactured products may have intentional splits for aesthetic purposes. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 84
  • 86. Exterior Finishing 4.26 CONDITION EXTERIOR WOOD TRIM IS BOWED, TWISTED OR CUPPED Acceptable Performance/Condition Exterior wood trim may warp, twist or cup. Loose trim or trim that falls off is not acceptable. Warranty One-Year – Work and Materials Two-Year – Cladding Detachment, Displacement or Deterioration • Warping, twisting or cupping resulting from normal shrinkage of materials caused by drying after construction, or normal wear and tear are not covered by the statutory warranty. Action Trim not meeting the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 85 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 87. Exterior Finishing 4.27 CONDITION PAINT ON REPAIRED AREAS DOESN’T MATCH Acceptable Performance/Condition Repainted areas shall match the original finished surface for colour, sheen and texture as closely as possible and be a properly painted surface. The repainted area shall be assessed by viewing, without magnification, from a minimum perpendicular distance of 1,500 mm under normal lighting conditions and from a normal viewing position. Warranty One-Year – Work and Materials Action Repainted areas not meeting the acceptable condition shall be repaired. Remarks Exact matches cannot be reasonably expected due to aging and environmental soiling. The extent of the repainting may have to be considered to ensure the match is as close as possible. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 86
  • 88. Exterior Finishing 4.28 CONDITION EXTERIOR PAINT, STAIN OR CLEAR FINISH BLISTERS AND PEELS Acceptable Performance/Condition Exterior paint, stain or clear finishes shall not deteriorate to the extent of exposing the substrate beneath; surfaces subject to foot traffic are exempt from this requirement. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear is not covered by the statutory warranty. Action Paint or stain not meeting the acceptable performance shall be repaired. Remarks Weathering of painted, stained or clear-coated exterior surfaces is normal. Discolouration of the wood beneath is evidence of failed clear finish. Excessive moisture in the substrate can contribute to premature finish deterioration. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 87 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 89. Exterior Finishing 4.29 CONDITION EXTERIOR PAINT OR STAIN HAS FADED Acceptable Performance/Condition Exterior paints and stains shall not fade or discolour in an uneven or random manner. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear, improper maintenance, or alterations, deletions or additions by the homeowner is not covered by the statutory warranty. Action Exterior paints and stains not meeting the acceptable condition shall be repaired. Remarks Fading of exterior paints and stains is normal and the degree of fading depends on environmental conditions, e.g. southern exposures. Exact matches of repainted areas cannot be expected due to aging and environmental soiling of the original finish. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 88
  • 90. Exterior Finishing 4.30 CONDITION MOULD OR MILDEW IS VISIBLE ON EXTERIOR PAINTED SURFACES Acceptable Performance/Condition Painted or finished surfaces shall be free of visible mould and mildew. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance or normal wear and tear is not covered by the statutory warranty. Action Exterior painted surfaces not meeting the acceptable performance shall be repaired. Remarks Mould or mildew is common in the natural environment. It can often form on painted surfaces and can usually be removed during normal home maintenance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 89 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 91. Exterior Finishing 4.31 CONDITION LEAK IN EXTERIOR WALL Acceptable Performance/Condition The building envelope shall be constructed to prevent water entry. Warranty Two-Year – Building Envelope Water Penetration Two-Year – Cladding Detachment, Displacement or Deterioration • Water penetration resulting from improper maintenance or normal wear and tear is not covered by the statutory warranty. Action Building envelopes not meeting the acceptable condition shall be repaired. Remarks Joints and cracks in exterior wall surfaces and around openings shall be properly sealed to prevent the entry of water. Caulking and sealants deteriorate under normal weather conditions and should be checked regularly. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 90
  • 92. Roofs 5.1 CONDITION ROOF RIDGE HAS SAGGED Acceptable Performance/Condition Roofs shall be constructed to ensure the ridge does not sag under normal design conditions in accordance with the Ontario Building Code. Warranty One-Year – Work and Materials Seven-Year – Major Structural Defect • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Roofs not meeting the acceptable performance shall be repaired. Remarks Heavy loads of ice and snow can damage a roof. Normal home maintenance should include professional removal of heavy buildups of ice and snow. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 91 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 93. Roofs 5.2 CONDITION ROOF TRUSSES OR RAFTERS ARE BOWED Acceptable Performance/Condition Roof framing members shall be sized and installed in accordance with the Ontario Building Code. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violations • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Roof framing members not meeting the acceptable performance shall be repaired. Remarks Deflection due to normal loading and bowing due to normal drying of wood framing materials is acceptable. Heavy loads of ice and snow can damage a roof. Normal home maintenance should include professional removal of heavy buildups of ice and snow. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 92
  • 94. Roofs 5.3 CONDITION ROOF APPEARS WAVY Acceptable Performance/Condition Roof sheathing shall be sized and installed in accordance with the Ontario Building Code. Warranty One-Year – Work and Materials Action Roof sheathing not meeting the acceptable performance shall be repaired. Remarks Roof sheathing shall be installed with proper joint spacing and support. Waviness between framing members may occur even when sheathing is properly installed. Frost patterns on a roof can give the appearance of waviness without the condition existing (e.g. frost outline on sheathing joints and over roof framing members). Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 93 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 95. Roofs 5.4 CONDITION LEAKS DUE TO SNOW OR RAIN DRIVEN INTO THE ATTIC THROUGH LOUVRES OR VENTS Acceptable Performance/Condition Attic vents must be designed to prevent the entry of rain, snow and insects and they shall be installed in accordance with the Ontario Building Code. Warranty One-Year – Ontario Building Code Violations Two-Year – Building Envelope Water Penetration • Water penetration resulting from improper maintenance or an act of God is excluded from the statutory warranty. Action Defective material or improper vent installation resulting in water penetration shall be repaired. Remarks During high wind pressures, slight amounts of precipitation may be driven into roof vents. This condition is warranted only where there is a demonstrated defect in work or material supplied by the builder. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 94
  • 96. Roofs 5.5 CONDITION ROOF OR FLASHING LEAKS Acceptable Performance/Condition Roofs and their associated flashings shall allow no water penetration under normal weather conditions. Warranty One-Year – Ontario Building Code Violations Two-Year – Building Envelope Water Penetration • Water leakage resulting from improper maintenance or an act of God is excluded from the statutory warranty. Secondary damage to property or any personal injury resulting from the water penetration is also excluded from the statutory warranty. Action Defects allowing water penetration through the roof or any associated flashings shall be repaired. Remarks Ice dams can cause water leakage during the winter. This condition is warranted if the ice dam results from a demonstrated defect in work or material supplied by the builder. The homeowner must take immediate steps to prevent damage to their property and report any losses to their home insurance provider. See Appendix A5 “How to Conduct a Water Test” for more information. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 95 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 97. Roofs 5.6 CONDITION INADEQUATE ATTIC VENTILATION Acceptable Performance/Condition Attics shall be ventilated in accordance with the Ontario Building Code. Warranty Two-Year – Ontario Building Code Health & Safety Violations • Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty. Action Attics not meeting the acceptable condition shall be repaired. Remarks Roof vents should be kept free of obstructions. Inadequate attic ventilation can lead to heat and moisture problems. Snow covering roof vents can obstruct ventilation. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 96
  • 98. Roofs 5.7 CONDITION ICE BUILDUP ON THE ROOF Acceptable Performance/Condition Ice and icicles are a natural occurrence on roofs. Warranty None. • Damage caused by improper maintenance is not covered by the statutory warranty. Action The builder is not required to take any action. Remarks Ice dams and icicles occur when the roof surface is warm enough to melt the snow but the air temperature is cold enough to re-freeze the melt water. Natural weather patterns, building exposure, roof design and elevated attic temperatures, due to both the insulating effects of snow accumulation on the roof and air leakage from the interior of the building, can contribute to ice forming on roofs. Professional removal of buildups of ice and snow can help reduce the likelihood of water leaks. See section 5.5 “Roof or Flashing Leaks” for water leakage resulting from ice dams. This condition is warranted only where there is a demonstrated Ontario Building Code violation or a defect in work or material supplied by the builder. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 97 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 99. Roofs 5.8 CONDITION ROOF SHINGLES HAVE BLOWN OFF Acceptable Performance/Condition Roof shingles shall be installed according to the Ontario Building Code and the manufacturer’s specifications. Warranty One-Year – Work and Materials • Damage resulting from acts of God is not covered by the statutory warranty. Action Roof shingles not meeting the acceptable performance shall be repaired. Remarks Severe weather and wind gusts can sometimes exceed the design limitations of the shingles. Different shingle types and materials have varying abilities to resist these forces. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 98
  • 100. Roofs 5.9 CONDITION TABS ON ASPHALT SHINGLES ARE NOT LINED UP Acceptable Performance/Condition Shingles shall be installed to provide a generally uniform pattern when viewed from a normal viewing position on the ground from any given location. Warranty One-Year – Work and Materials Action Shingles not meeting the acceptable condition shall be repaired. Remarks The primary role of roofing is to protect the building from the weather. Slight variation in the appearance of the roof is acceptable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 99 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 101. Roofs 5.10 CONDITION ASPHALT SHINGLES NOT SEALED Acceptable Performance/Condition Asphalt shingles and self-sealing asphalt shingles shall be secured according to the Ontario Building Code and manufacturer’s specifications. Warranty One-Year – Work and Materials Action Shingles not meeting the acceptable condition shall be repaired. Remarks Asphalt shingles installed in temperatures below 5°C will seal when warmer temperatures return. In the short term, unsealed shingles should not affect the weather protection provided by the roof. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 100
  • 102. Roofs 5.11 CONDITION ASPHALT SHINGLE EDGES ARE CURLED OR CUPPED Acceptable Performance/Condition Asphalt shingle edges and corners need not be completely flat. Edges and corners that curl or cup to expose the uncoloured portion of the shingle below are not acceptable. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear is not covered by the statutory warranty. Action Shingles not meeting the acceptable condition shall be repaired. Remarks Adequate attic ventilation is necessary to prevent excessive solar heat buildup in the attic that can contribute to curling and cupping. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 101 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 103. Roofs 5.12 CONDITION ASPHALT SHINGLES EITHER DO NOT OVERHANG THE EDGE OF THE ROOF OR HANG OVER TOO FAR Acceptable Performance/Condition Asphalt shingles shall overhang roof edges by not less than 12 mm according to the Ontario Building Code; they shall not overhang the roof edge to the extent that they curl. Warranty One-Year – Work and Materials Action Shingle overhangs not meeting the acceptable condition shall be repaired. Remarks The edge of the roof includes the entire perimeter of the roof including gables. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 102
  • 104. Roofs 5.13 CONDITION SHADING PATTERN IS VISIBLE ON AN ASPHALT SHINGLE ROOF Acceptable Performance/Condition At installation, asphalt shingle roofs shall be installed so that any dye lot difference is minimized to provide a uniform roof appearance, when viewed from a normal viewing position on the ground without magnification by reflected light. Warranty One-Year – Work and Materials Action Shingles not meeting the acceptable condition shall be repaired. Remarks Shading variations resulting from dye lot difference are acceptable. See section 5.14 “Variation in Colour After Repairs” for colour and shading of local repairs. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 103 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 105. Roofs 5.14 CONDITION VARIATION IN COLOUR AFTER REPAIRS Acceptable Performance/Condition Shingles used in local repairs shall be of similar type, texture and colour. Variation resulting from fading or different dye lot is acceptable. Warranty One-Year – Work and Materials Action Shingles not meeting the acceptable condition shall be repaired. Remarks The primary role of roofing is to protect the building from the weather. Slight variation in the colour of the roof after a local repair may be unavoidable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 104
  • 106. Roofs 5.15 CONDITION UNEVEN ROOF SHEATHING CAUSING VISIBLE IRREGULARITIES IN THE ROOF SURFACE Acceptable Performance/Condition Asphalt shingle surfaces need not be completely flat. The roof sheathing shall provide an even surface free from thickness variations, holes, and debris that produce visible irregularities in the finished roof. The roof shall be viewed from a normal viewing position on the ground without magnification by reflected light. Warranty One-Year – Work and Materials Action Roofs not meeting the acceptable condition shall be repaired. Remarks Visible irregularities shall be significant enough to suggest a defective condition. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 105 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 107. Roofs 5.16 CONDITION ROOFING NAILS ARE EXPOSED Acceptable Performance/Condition Roofing nails shall be covered by overlapping shingles or by sealing. Warranty One-Year – Work and Materials Action Roofs with nails not meeting the acceptable condition shall be repaired. Remarks The overlying shingle must cover the nails to ensure adequate weather protection. Sealant applied to nails shall not detract from the overall uniform roof appearance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 106
  • 108. Roofs 5.17 CONDITION TEMPORARY SAFETY STRAPS LEFT ON ROOF Acceptable Performance/Condition Safety straps intended to be used only during construction shall not be left on the roof. Warranty One-Year – Work and Materials Action Temporary safety straps shall be removed. Remarks Temporary safety straps are used during construction and there is no need for them to remain on the roof after construction, unless required by other authorities. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 107 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 109. Roofs 5.18 CONDITION WATER IS TRAPPED UNDER ROOFING MEMBRANE Acceptable Performance/Condition Water shall not become trapped under built-up or single-ply roofing membranes. Warranty One-Year – Work and Materials Two-Year – Building Envelope Water Penetration Action Roofing not meeting the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 108
  • 110. Roofs 5.19 CONDITION ASPHALT ROLL ROOFING IS BLISTERED BUT DOES NOT ADMIT WATER Acceptable Performance/Condition Roll roofing may blister under normal weather conditions. Blisters that result in water penetration are not acceptable. Warranty One-Year – Work and Materials Action Roofing not meeting the acceptable condition shall be repaired. Remarks Surface blistering of roll roofing may be caused by solar heating and humidity. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 109 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 111. Roofs 5.20 CONDITION STANDING WATER ON A FLAT ROOF Acceptable Performance/Condition Flat roofs shall be installed to drain water. Standing water on roofs designed for water retention is acceptable. Warranty One-Year – Work and Materials Action Roofs not meeting the acceptable condition shall be repaired. Remarks Flat roofs typically are slow to drain and should be constructed to handle exposure to standing water over short terms. Municipalities can require flow control devices to be installed on roof drains. Some standing water is normal and should generally dissipate after a few days. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 110
  • 112. Roofs 5.21 CONDITION EAVESTROUGHS OR DOWNSPOUTS LEAK Acceptable Performance/Condition Eavestroughs and downspouts shall not leak at joints. Warranty One-Year – Work and Materials Action Eavestroughs and downspouts not meeting the acceptable performance shall be repaired. Remarks Water hitting and dripping off the outside of eavestroughs and downspouts should not be mistaken for leakage. Seasonal conditions may affect the timing of repairs. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 111 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 113. Roofs 5.22 CONDITION EAVESTROUGHS OVERFLOW DURING NORMAL RAIN Acceptable Performance/Condition Eavestroughs shall be installed in accordance with municipal requirements (where applicable) with a slope to downspouts or drains. Eavestroughs may overflow during a rain as a result of converging water flows. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear or an act of God is excluded from the statutory warranty. Action Eavestroughs not meeting the acceptable condition shall be repaired. Overflow resulting from inadequate slope or non-conformance with municipal requirements is subject to the statutory warranty. Remarks The homeowner shall keep eavestroughs and downspouts free from environmental debris or physical damage that could cause blockage or restrict water flow. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 112
  • 114. Roofs 5.23 CONDITION EAVESTROUGHS OR DOWNSPOUTS NOT PERFORMING PROPERLY Acceptable Performance/Condition Where provided, eavestroughs and downspouts shall collect water from the roof and drain it to grade. Where downspouts are not connected to a sewer, extensions shall be provided to carry rainwater away from the building in a manner that will prevent soil erosion. Warranty One-Year – Work and Materials Action Eavestroughs and downspouts not meeting the acceptable performance shall be repaired. Remarks Normal home maintenance includes keeping the eavestroughs and downspouts free of debris that can clog the system. Extensions may include splash pads set on the ground. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 113 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 115. Roofs 5.24 CONDITION EAVESTROUGHS DON’T DRAIN COMPLETELY Acceptable Performance/Condition Eavestroughs shall generally slope to drains. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance is not covered by the statutory warranty. Action Eavestroughs not meeting the acceptable condition shall be repaired. Remarks Some minimal amount of standing water is normal. Normal home maintenance includes keeping the eavestroughs and downspouts free of debris that can clog the system. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 114
  • 116. Roofs 5.25 CONDITION SKYLIGHT LEAKS Acceptable Performance/Condition Skylights shall be installed in accordance with the manufacturer’s specifications and shall not allow water penetration. Warranty Two-Year – Building Envelope Water Penetration • Damage resulting from dampness or condensation due to failure by the homeowner to maintain adequate ventilation is not covered by the statutory warranty. Action Skylights not meeting the acceptable performance shall be repaired. Remarks Condensation on the interior surfaces of a skylight may occur if indoor relative humidity is high. Condensation is not considered indicative of a defective condition. To test for water penetration, see Appendix A5 “How to Conduct a Water Test”. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 115 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 117. Plumbing 6.1 CONDITION INADEQUATE WATER SUPPLY Acceptable Performance/Condition Water supply from private water sources (e.g. wells) may fluctuate from time to time. Water supply from municipal water sources may vary with the supplied pressure. Warranty None. Action None. Remarks Confirm proper operation of faucets and fixtures during the PDI and record any malfunction on the PDI Form, to avoid any dispute about whether the damage was caused by the builder. The Ontario Building Code requires flow control devices on faucets, showerheads, and fixtures for water conservation purposes, which can affect the water flow. After occupancy, the builder is not responsible for contamination or reduced water capacity from private water sources provided it can be shown there was an adequate supply of potable water at the time of occupancy. Variations in pressure from municipal services can occur during peak usage times, from burst water mains or fire protection services using the system. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 116
  • 118. Plumbing 6.2 CONDITION THE DOMESTIC WATER SUPPLY SYSTEM DOES NOT DELIVER WATER Acceptable Performance/Condition The domestic water supply system supplied and installed by the builder shall be capable of delivering water from a municipal or private (well) source throughout the home. Warranty One-Year – Work and Materials on pumps supplying water from a private well Two-Year – Delivery and Distribution Systems • Damage resulting from improper maintenance or additions, deletions or alterations made by a homeowner is excluded from the statutory warranty. • Damage caused by municipal services or other utilities is excluded from the statutory warranty. Action Domestic water supply systems not meeting the acceptable performance shall be repaired. Remarks Conditions beyond the control of the builder, such as burst water mains and periods of drought affecting groundwater levels that disrupt or eliminate the water supply, are not covered by the statutory warranty. See 6.1 for Inadequate Water Supply. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 117 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 119. Plumbing 6.3 CONDITION PIPES ARE LEAKING Acceptable Performance/Condition Domestic water supply and drainpipes shall not leak. Warranty Two-Year – Delivery and Distribution Systems • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. • Secondary damage caused by defects, such as property damage or personal injury, is excluded from the statutory warranty. Action Pipes not meeting the acceptable performance shall be repaired. Remarks Condensation on piping should not be mistaken for a leaking pipe. Condensation on cold-water supply pipes is not covered by the statutory warranty. High indoor humidity is the main cause of condensation on pipes. If a leak is detected in a water supply pipe, the main water supply valve should be turned off immediately until the builder’s representative can assess the condition. For more information on emergency situations, please refer to the Homeowner Information Package. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 118
  • 120. Plumbing 6.4 CONDITION FAUCET OR FIXTURE IS LEAKING Acceptable Performance/Condition Faucets or plumbing fixtures shall not leak, drip or run on when fully closed or shut off. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance, normal wear and tear, or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. • Secondary damage caused by defects, such as property damage or personal injury, is excluded from the statutory warranty. Action Faucets or fixtures not meeting the acceptable performance shall be repaired. Remarks Confirm proper operation of faucets and fixtures during the PDI and record any malfunction on the PDI Form, to avoid any dispute about whether the damage was caused by the builder. Some manufacturers of plumbing products offer warranties on their products that extend beyond the one-year statutory warranty. If a leak occurs after the one-year statutory warranty, service may be available from the manufacturer. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 119 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 121. Plumbing 6.5 CONDITION PLUMBING PIPES ARE FROZEN AND/OR BURST Acceptable Performance/Condition Plumbing pipes shall be protected from freezing in accordance with the Ontario Building Code. Warranty Two-Year – Delivery and Distribution Systems • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. • Secondary damage caused by defects, such as property damage or personal injury, is excluded from the statutory warranty. Action Plumbing pipes not meeting the acceptable condition shall be repaired. Remarks Homes must be kept at temperatures to prevent freezing at all times. If this is not possible, proper precautions should be taken to prevent freezing such as shutting off and draining the water supply system. For exterior hose bibs, shut off any associated interior valves and leave the exterior valve open as part of a regular seasonal maintenance program. Garden hoses must also be disconnected from the exterior hose bib. If a burst pipe is detected in a water supply pipe, the main water supply valve should be turned off immediately until the builder’s representative can assess the condition. For more information on emergency situations, please refer to the Homeowner Information Package. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 120
  • 122. Plumbing 6.6 CONDITION BATHTUB OR SHOWER LEAKS Acceptable Performance/Condition Bathtubs and showers shall be installed in accordance with manufacturer’s specifications so they do not leak. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. • Secondary damage caused by defects, such as property damage or personal injury, is excluded from the statutory warranty. Action Bathtubs or showers not meeting the acceptable performance shall be repaired. Remarks Caulking and seals around bathtubs and shower enclosures and entry door seals require regular homeowner inspection and maintenance to prevent leaks. If a leak is detected in a water supply pipe, the main water supply valve should be turned off immediately until the builder’s representative can assess the condition. For more information on emergency situations, please refer to the Homeowner Information Package. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 121 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 123. Plumbing 6.7 CONDITION CONDENSATION APPEARS ON WATER SUPPLY PIPES AND TOILETS Acceptable Performance/Condition Condensation on water supply pipes and toilets may occur when indoor relative humidity is high. Warranty None. Action None. Remarks Condensation may appear on water supply lines and toilets from time to time and is normal. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 122
  • 124. Plumbing 6.8 CONDITION NOISY WATER PIPES OR “WATER HAMMER” Acceptable Performance/Condition Water supply pipes shall be installed to minimize the effects of water hammer and in accordance with the Ontario Building Code. Drainage pipes shall be installed in accordance with the Ontario Building Code. Warranty Two-Year – Delivery and Distribution Systems • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. • Secondary damage caused by defects, such as property damage or personal injury, is excluded from the statutory warranty. Action Plumbing pipes not meeting the acceptable performance shall be repaired. Remarks Hammering of water supply pipes during normal operation may indicate a problem and should be investigated. A sudden thump or bang of water supply pipes when a faucet or fixture is closed abruptly is normal and not covered by the statutory warranty. Slight “ticking” sounds coming from copper hot water supply pipes as they expand are normal and are not covered by the statutory warranty. The sound of water flowing through drainage pipes is normal and not covered by the statutory warranty. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 123 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 125. Plumbing 6.9 CONDITION DEFECTIVE PLUMBING FIXTURES, APPLIANCES OR TRIM FITTINGS Acceptable Performance/Condition Plumbing fixtures, appliances or trim fittings shall be free of both visual and performance defects. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance is excluded from the statutory warranty. Action Defective products shall be repaired or replaced. Remarks Confirm proper operation of plumbing fixtures during the PDI and record any malfunction on the PDI Form, to avoid any dispute about whether the damage was caused by the builder. Plumbing fixtures, appliances or trim fittings must be maintained in accordance with the manufacturer’s instructions. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 124
  • 126. Plumbing 6.10 CONDITION CRACKING OR CHIPPING OF PORCELAIN, ENAMEL OR FIBREGLASS SURFACES Acceptable Performance/Condition Surfaces exposed to view shall be free from visible damage at the time of the PDI. Warranty One-Year – Work and Materials • Damage not recorded on the PDI Form is excluded from the statutory warranty, unless the homeowner is able to establish that the damage was caused by the builder. • Damage resulting from normal wear and tear is excluded from the statutory warranty. Action Visible damage shall be repaired. Remarks Identify any damaged porcelain, enamel or fibreglass surfaces on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Maintain porcelain, enamel or fibreglass surfaces in accordance with the manufacturer’s instructions. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 125 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 127. Plumbing 6.11 CONDITION LIGHTWEIGHT (FIBREGLASS AND ACRYLIC) BATHTUB OR SHOWER BASE FLEXES AND CREAKS Acceptable Performance/Condition Lightweight bathtubs and showers may flex and creak when installed in accordance with manufacturer’s specifications. Warranty One-Year – Work and Materials Action Bathtubs or showers not meeting the acceptable condition shall be repaired. Remarks Fibreglass and acrylic bathtubs and shower enclosures are lightweight yet strong. Flexing or creaking sounds can often be heard especially in large soaker-type tubs as they are filled and emptied. These fixtures are designed to withstand this type of flexing; it does not generally represent a manufacturing or installation defect. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 126
  • 128. Plumbing 6.12 CONDITION MANUFACTURED SOLID-SURFACE COUNTERTOP (INTEGRATED BASIN) CRACKS AT THE DRAIN Acceptable Performance/Condition Manufactured solid-surface countertops shall be installed to prevent stress cracking and in accordance with the manufacturer’s specifications. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Manufactured solid-surface countertops not meeting the acceptable performance shall be repaired. Remarks Identify any damaged countertops during the PDI and record any damage on the PDI Form, to avoid any dispute about whether the damage was caused by the builder. Manufactured solid-surface countertops can be brittle and damaged by impact. Over-tightening of drains or fasteners may cause stress cracks. Care should be taken when cleaning or servicing to prevent cracking or chipping. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 127 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 129. Plumbing 6.13 CONDITION TOILET TAKES MORE THAN ONE FLUSH TO EMPTY Acceptable Performance/Condition Toilets (water closets) shall flush waste into the drainage system. Warranty One-Year – Work and Materials • Drain restrictions due to improper maintenance are excluded from the statutory warranty. Action Where defective installation or product is determined repairs shall be made. Remarks Newer low-volume toilets, which are required for new homes by the Ontario Building Code, use less water to flush waste than older models, making their operation more sensitive to the effects of the: • amount of waste • amount of paper • volume of water in the tank As a result, multiple flushes may be required. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 128
  • 130. Plumbing 6.14 CONDITION SEWER, DRAINS OR FIXTURES BLOCKED Acceptable Performance/Condition Sanitary drainage systems and fixtures shall drain waste products to a public sanitary sewer or private sewage disposal system without interruption. Warranty One-Year – Work and Materials Two-Year – Delivery and Distribution Systems Seven-Year – Major Structural Defect (private sewage disposal systems only) • Damage caused by blocked sanitary drainage systems resulting from vegetation (e.g., tree roots), alterations made by the homeowner, improper maintenance or use, or caused by municipal services or other utilities is excluded from the warranty. Action • Complete failure of sanitary drainage systems is considered to be an emergency. • The builder shall effect repairs within 24 hours of receiving notice from the homeowner. If the homeowner cannot contact the builder, the homeowner must follow the “Emergency Situations” rules in the Homeowner Information Package. • If the homeowner expects to be reimbursed for repairs, the repairs must be documented to clearly identify the nature of the problem and repair and be illustrated with photographs. • The builder is only responsible for reimbursement where the cause of failure results from work or material supplied by the builder. In all other cases, the homeowner is responsible for the cost of repairs. Remarks With respect to septic systems, improper maintenance by the homeowner includes: • Connection of sump pump, roof drains, or backwash from a water conditioner into the system. • Placement of non-biodegradable items into the system. • Use of a food waste disposal. • Placement of surfaces not permeable to water over the disposal area of the system. • Allowing vehicles to drive or park over the disposal area of the system. • Failure to pump out the septic tank periodically, as required. • Use that exceeds the system’s design standards. Words in italics are defined in the “Terminology” section on pages 15-17. Construction Performance Guidelines Second Edition, effective December 1, 2003 129 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 131. Electrical 7.1 CONDITION FUSES BLOW OR CIRCUIT BREAKERS TRIP Acceptable Performance/Condition Electrical circuits shall be installed in accordance with the Ontario Electrical Code. Warranty Two-Year – Delivery and Distribution Systems • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. • Secondary damage caused by defects, such as property damage or personal injury, is excluded from the statutory warranty. Action Electrical circuits not meeting the acceptable performance shall be repaired. Remarks Circuit breakers protect electrical wiring from overloading. Frequent tripping of circuit breakers or blown fuses could result from faulty appliances and should be investigated. Some appliances have special power requirements. Care should be taken not to overload or bypass electrical circuits. Personal injury or fire can result. Typical household wiring is installed to accommodate residential electrical loads. Specific requirements should be discussed with the builder prior to installation. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 130
  • 132. Electrical 7.2 CONDITION GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) TRIPS FREQUENTLY Acceptable Performance/Condition GFCIs shall be installed in accordance with the Ontario Electrical Code. Warranty Two-Year – Delivery and Distribution Systems • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Electrical circuits protected by a GFCI not meeting the acceptable condition shall be repaired. Remarks GFCIs are sensitive safety devices installed to provide protection against electrical shock, especially in wet areas. These devices can be tripped and reset easily. Frequent tripping may indicate an appliance fault and should be investigated. GFCIs are often interconnected with plain receptacles to protect an entire circuit. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 131 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 133. Electrical 7.3 CONDITION ELECTRICAL OUTLETS OR SWITCHES DON’T WORK Acceptable Performance/Condition Electrical outlets and switches shall be installed in accordance with manufacturer’s specifications and the Ontario Electrical Code. Warranty Two-Year – Delivery and Distribution Systems • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. • Secondary damage caused by defects, such as property damage or personal injury, is excluded from the statutory warranty. Action Electrical outlets and switches not meeting the acceptable performance shall be repaired. Remarks Test the operation of electrical outlets and switches during the PDI and record damage on the PDI Form, to avoid any dispute about whether the damage was caused by the builder. Check the electrical circuit panel when a receptacle or switch fails to work. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 132
  • 134. Electrical 7.4 CONDITION ELECTRICAL FIXTURE DOESN’T WORK Acceptable Performance/Condition Electrical fixtures supplied and installed by the builder shall be installed in accordance with the manufacturer’s specifications and the Ontario Electrical Code. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. • Secondary damage caused by defects, such as property damage or personal injury, is excluded from the statutory warranty. Action Electrical fixtures not meeting the acceptable performance shall be repaired. Remarks Identify damaged electrical fixtures on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Check the electrical circuit panel when a receptacle or switch fails to work. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 133 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 135. Electrical 7.5 CONDITION RECEPTACLE/SWITCH COVER PLATE IS NOT FLUSH WITH THE WALL Acceptable Performance/Condition Electrical receptacles/switches shall be installed so that the cover plate sits generally flush with the adjacent wall surface. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Receptacles/switch cover plates not meeting the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 134
  • 136. Electrical 7.6 CONDITION EXHAUST FAN DUCT TERMINATES IN ATTIC OR CRAWL SPACE Acceptable Performance/Condition Exhaust fans shall be ducted to the exterior in accordance with the Ontario Building Code. Warranty Two-Year – Ontario Building Code Health and Safety Violations • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Exhaust fans not meeting the acceptable performance shall be repaired. Remarks Exhaust fans and clothes dryers should never be ducted into heated or unheated enclosed spaces such as basements, attics and soffits, or attached garages. Moisture buildup in these areas can cause damage. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 135 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 137. Electrical 7.7 CONDITION INTERIOR LIGHT FIXTURE TARNISHED Acceptable Performance/Condition Interior light fixtures supplied and installed by the builder shall not tarnish. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Light fixtures not meeting the acceptable condition shall be repaired. Remarks Discolouration may occur due to the normal operation of the fixture. Exceeding the manufacturer’s specification for bulb wattage may also cause discolouration, which is not covered by the statutory warranty. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 136
  • 138. Electrical 7.8 CONDITION CEILING FAN VIBRATES AND IS NOISY Acceptable Performance/Condition Ceiling fans shall be installed and maintained in accordance with the manufacturer’s installation instructions. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance, normal wear and tear, or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Ceiling fans not meeting the acceptable performance shall be repaired. Remarks Some vibration is normal. Ceiling fans can operate at high speeds and can become unbalanced, resulting in excessive vibration. Ceiling fans require regular maintenance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 137 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 139. Interior Climate Control 8.1 CONDITION DRAFT FELT AT ELECTRICAL OUTLET Acceptable Performance/Condition Electrical boxes on exterior walls that penetrate the air barrier system shall be installed to prevent air infiltration. Warranty One-Year – Work and Materials Action Electrical boxes not meeting the acceptable condition shall be repaired. Remarks Some drafts may occur around electrical outlets or receptacles on exterior walls, particularly when it is cold or windy. Convection air movement may simulate draft conditions. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 138
  • 140. Interior Climate Control 8.2 CONDITION AIR INFILTRATION THROUGH WINDOWS AND DOORS Acceptable Performance/Condition Windows and doors shall meet the rating for weathertightness required by the Ontario Building Code. Warranty One-Year – Work and Materials Action Ensure the window or door has been tested to meet the required weathertightness rating. Adjust weatherstripping and/or hardware to reduce air leakage by ensuring positive contact along the weather seal. Remarks Doors and windows must be properly closed to ensure positive contact with weatherstripping. Doors and windows are manufactured to meet specifications for weathertightness and are designed to withstand reasonable wind loads. Minor air infiltration may occur during very windy conditions. Weatherstripping becomes worn with use and should be inspected and replaced by the homeowner on a regular basis. Interior air movement caused by convection should not be confused with actual air leakage through the window and doors. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 139 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 141. Interior Climate Control 8.3 CONDITION KITCHEN OR BATH FANS ALLOW COLD AIR INFILTRATION OR DRAFTS Acceptable Performance/Condition Kitchen and bath exhaust fans shall be installed with backdraft dampers as per manufacturer’s specifications. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Kitchen and/or bath exhaust fans not meeting the acceptable condition shall be repaired. Remarks Because they are connected to the exterior by a duct, ventilation fans are indirectly open to outside air. Even though these types of fans come equipped with dampers, they are not completely effective at eliminating cold air infiltration. Sometimes they can become obstructed and not close fully. As part of regular home maintenance, vent terminations on exterior walls should be inspected periodically to ensure the openings are not obstructed (e.g. by birds or other animals). Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 140
  • 142. Interior Climate Control 8.4 CONDITION CONDENSATION IN ATTIC SPACE Acceptable Performance/Condition Condensation may occur in attics but these occurrences should be infrequent and without any adverse effect on the building. Warranty Two-Year – Ontario Building Code Health & Safety Violations • Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty. Action Adequate ventilation equipment shall be installed in accordance with the Ontario Building Code. Remarks Attic spaces shall be ventilated in accordance with the Ontario Building Code. Condensation in attics may indicate either a lack of ventilation through the attic or a source of moisture within the attic space. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 141 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 143. Interior Climate Control 8.5 CONDITION CONDENSATION AND/OR FROST ON WINDOWS Acceptable Performance/Condition Condensation may occur on interior window surfaces. Warranty None. • Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty. Action None. Remarks Condensation occurs when water vapour in indoor air contacts cool surfaces such as window glass. Condensation on interior window surfaces is common during cold seasons. When outdoor temperatures are well below freezing, ice may form at the bottom of the window. Since it is important for homeowners to maintain proper humidity levels within the home to prevent damage to other components such as hardwood flooring and for physical health, some condensation on windows may be expected. Indoor humidity levels may be controlled by dehumidification, ventilation or air conditioning. Interior air moving over the windows can help control condensation. Heavy draperies or window coverings that cover windows and block heat diffusers can prevent air flow. Running the furnace fan continuously can also help to control condensation on windows. See Appendix A3 “Moisture and Windows”. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 142
  • 144. Interior Climate Control 8.6 CONDITION CONDENSATION ON INTERIOR DUCTWORK AND AIR HANDLING EQUIPMENT Acceptable Performance/Condition Condensation may occur on indoor ductwork and air handling equipment. Warranty None. • Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty. Action None. Remarks This condition may occur in the summer when air conditioning equipment is operating or in winter when ducts are chilled by incoming outdoor air. For example, condensation may occur on range hood exhaust ducts during cold outdoor temperatures. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 143 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 145. Interior Climate Control 8.7 CONDITION INSUFFICIENT INSULATION Acceptable Performance/Condition Insulation shall be installed in accordance with the Ontario Building Code. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violations Action Insulation levels not meeting the acceptable condition shall be repaired. Remarks Several factors affect living space temperatures: a) Proper installation of insulation shall include correct placement behind electrical boxes, backing studs, corner framing and wiring, and around window and door openings. b) Directional orientation – north-facing rooms are generally cooler than south-facing rooms. c) Windows – glass has little insulating value and allows more heat to escape from the room. d) Rooms over garages – have insulated floors that lose heat to the unheated garage below. e) Airflow – free airflow from the supply outlet in a room to a return inlet or undercut door is essential. Generally, a minimum 25 mm space under interior doors above the finished floor covering should be provided. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 144
  • 146. Interior Climate Control 8.8 CONDITION HEATING, VENTILATING OR AIR CONDITIONING (HVAC) SYSTEMS NOT INSTALLED PROPERLY Acceptable Performance/Condition HVAC appliances shall be installed to meet the manufacturer’s specifications and the Ontario Building Code. Ductwork and piping shall be joined and supported to maintain joint integrity. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violations Two-Year – Heating Delivery and Distribution Systems • Damage resulting from alterations, deletions or additions by the homeowner, or improper maintenance, is excluded from the statutory warranty. Action Where builder-supplied and -installed appliances, ductwork and piping do not meet the acceptable performance, repairs shall be made. Remarks Confirm proper operation of the HVAC system during the PDI. Defects discovered after the PDI will be covered by the statutory warranty if they result from the builder’s work. Appliances such as the furnace and water heater are located at the discretion of the builder within the requirements of the governing authority. Duct tape is not generally required. For equipment performance requirements see sections 8.9 “Inadequate Heating” and 8.10 “Inadequate Cooling”. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 145 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 147. Interior Climate Control 8.9 CONDITION INADEQUATE HEATING Acceptable Performance/Condition Heating systems shall be capable of maintaining an indoor air temperature of: a) 22°C in living spaces and unfinished basements b) 15°C in crawl spaces; at the design temperature for the geographical location. Warranty One-Year – Work and Materials Two-Year – Delivery and Distribution Systems • Damage resulting from alterations, deletions or additions made by the homeowner and from improper maintenance is excluded from the statutory warranty. Action Where the heating system is not capable of maintaining the prescribed temperature, repairs shall be made. Remarks Several factors affect living space temperatures: a) Directional orientation – north-facing rooms are generally cooler than south-facing rooms. b) Windows – glass has little insulating value and allows more heat to escape from the room. c) Rooms over garages – have insulated floors that lose heat to the unheated garage below. d) Airflow – free airflow from the supply outlet in a room to a return inlet or undercut door is essential. Generally, a minimum 25 mm space under interior doors above the finished floor covering should be provided. e) Personal preference – personal comfort differs between individuals. Balancing the air delivery system may not completely compensate for the effects of these factors. In determining the temperature of a room, measurements shall be taken in the center of the room at 1,500 mm above the floor after the heating system has been running continuously for at least 20 minutes. Heat loss calculations and duct designs assist in determining the furnace size and adequacy of the heating system. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 146
  • 148. Interior Climate Control 8.10 CONDITION INADEQUATE COOLING Acceptable Performance/Condition Cooling systems shall be capable of maintaining an indoor air temperature of 24°C at the design temperature for the geographical location. Warranty One-Year – Work and Materials Two-Year – Delivery and Distribution Systems • Defects in materials, design and work supplied by the homeowner, and damage resulting from improper maintenance, or from alterations, deletions or additions made by the homeowner are excluded from the statutory warranty. Action Where the cooling system is not capable of achieving the acceptable performance, repairs shall be made. Remarks Sustained high outdoor temperatures exert large loads on cooling equipment; indoor temperatures will rise until outdoor temperatures return to design levels. Skylights and large window areas can allow sunlight and heat to transfer easily into the home. Temperatures tend to vary in a multi-storey home due to normal air movement patterns. Heat gain calculations and duct designs assist in determining the equipment size and adequacy of the cooling system. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 147 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 149. Interior Climate Control 8.11 CONDITION NOISY DUCTWORK Acceptable Performance/Condition Ductwork may make noise as it expands and contracts during heating and cooling cycles. Warranty None. Action None. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 148
  • 150. Interior Climate Control 8.12 CONDITION DUCTWORK MAKES NOISE WHEN FLOOR IS WALKED ON – COMMONLY KNOWN AS “OIL CANNING” Acceptable Performance/Condition Ductwork shall be constructed and installed to prevent “oil canning”. Warranty One-Year – Work and Materials • Damage due to normal shrinkage of materials caused by drying after construction is not covered by the statutory warranty. Action Ductwork not meeting the acceptable performance shall be repaired. Remarks Weight transfer on floors over metal ductwork can sometimes result in a temporary deflection of the metal ductwork. Shrinkage of floor joists may cause “oil canning”. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 149 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 151. Interior Climate Control 8.13 CONDITION NOISE CAN BE HEARD AT REGISTER Acceptable Performance/Condition Floor registers and cold air return grilles shall be installed to prevent rattling. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance, or from additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Floor registers or cold air return grilles not meeting the acceptable condition shall be repaired. Remarks The sound of air movement at floor registers or cold air return grilles is normal, but they should not rattle under normal use. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 150
  • 152. Interior Climate Control 8.14 CONDITION DUCTWORK COMES APART Acceptable Performance/Condition Ductwork shall be joined and supported to prevent separation or detachment and maintain joint integrity. Warranty Two-Year – Delivery and Distribution Systems • Damage resulting from improper maintenance, or from additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Ductwork not meeting the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 151 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 153. Interior Climate Control 8.15 CONDITION CONDENSATE LINE IS BLOCKED Acceptable Performance/Condition Condensate lines from furnaces, air conditioning condenser coils and heat recovery ventilators shall be free from blockage. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear or improper maintenance is excluded from the statutory warranty. Action Condensate lines not meeting the acceptable condition shall be repaired. Remarks Where conditions permit, confirm the proper operation of the furnace, air conditioner and heat recovery ventilators during the PDI and record any malfunction on the PDI Form, to avoid any dispute about whether the damage was caused by the builder. Condensate lines should be inspected and cleaned as part of regular home maintenance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 152
  • 154. Interior Climate Control 8.16 CONDITION AIR CONDITIONING COOLANT LINE LEAKS Acceptable Performance/Condition Air conditioning systems supplied and installed by the builder shall not leak. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance, or from additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Air conditioning systems not meeting the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 153 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 155. Interior Climate Control 8.17 CONDITION THERE ARE GAPS BETWEEN HEAT DIFFUSERS, COLD AIR RETURN GRILLES AND VENTILATION GRILLES AND THE ADJACENT SURFACE Acceptable Performance/Condition Heat diffusers, cold air return grilles and ventilation intake grilles shall be installed securely and be generally flush with the adjacent surface. Minor gaps between the diffuser or grille and the adjacent surface are acceptable. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance, or from additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Heat diffusers, cold air return grilles and ventilation grilles not meeting the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 154
  • 156. Wall and Ceiling Finish 9.1 CONDITION CEILING IS UNEVEN Acceptable Performance/Condition Within a room or space, ceilings shall appear uniform when viewed from a normal viewing position under normal lighting conditions. Where an isolated sag, bulge or area of waviness appears and is not a structural problem, the variation from the specified plane shall not exceed ±12 mm. Warranty One-Year – Work and Materials • Undulations caused by normal shrinkage of materials due to drying after construction are excluded from the statutory warranty. Action Sags or waves in ceilings greater than the acceptable performance shall be repaired. Remarks Even when installed according to the Ontario Building Code, it is not unusual to see undulation in drywalled ceilings due to joint finishing. This occurrence can be exaggerated by particular or critical lighting conditions and glossy finishes. Spray-applied textures and matte finishes minimize this condition. Some undulations may also be caused by truss uplift and applying ceiling drywall over major structural components such as beams. See section 9.5 “Ceiling/Wall Joint Separation Commonly Referred to as Truss Uplift”. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 155 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 157. Wall and Ceiling Finish 9.2 CONDITION CEILING TEXTURE IS UNEVENLY APPLIED Acceptable Performance/Condition In a room or area, applied ceiling texture (i.e. stipple) shall appear generally uniform when viewed from a normal viewing position under normal lighting conditions. Warranty One-Year – Work and Materials Action Ceiling texture not meeting the acceptable condition shall be repaired. Remarks Minor variation in texture is normal with randomly applied finishing materials. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 156
  • 158. Wall and Ceiling Finish 9.3 CONDITION GYPSUM WALLBOARD CORNERS ARE UNEVEN Acceptable Performance/Condition Gypsum wallboard corners shall appear generally even and uniform when viewed under normal lighting conditions from a normal viewing position. Warranty One-Year – Work and Materials Action Joints not meeting the condition shall be repaired. Remarks Minor waviness may be more apparent in corners that are not right-angled and is acceptable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 157 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 159. Wall and Ceiling Finish 9.4 CONDITION CRACKS IN INTERIOR WALL AND CEILING SURFACES Acceptable Performance/Condition Interior drywall shall be installed to minimize cracking of joints, corners and corner beads. Warranty One-Year – Work and Materials • Cracks resulting from normal shrinkage of materials due to drying after construction are excluded from the statutory warranty. Action Only warranted cracks shall be repaired and refinished to match original builder-applied finish as closely as possible. Remarks Cracks are not unusual in drywall compound at joints, particularly at corners. Most cracks are a result of normal shrinkage and are generally not warranted. The repair of normal shrinkage cracks is at the builder’s discretion and sanding and repainting is not required. Builder’s specific policies with respect to drywall repair will vary. These repairs are best left until the framing has settled. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 158
  • 160. Wall and Ceiling Finish 9.5 CONDITION CEILING/WALL JOINT SEPARATION COMMONLY REFERRED TO AS “TRUSS UPLIFT” Acceptable Performance/Condition Cracks resulting from normal shrinkage are acceptable; crack width in excess of 4 mm is not acceptable. Warranty One-Year – Work and Materials • Cracks resulting from normal shrinkage of materials caused by drying after construction are excluded from the statutory warranty. Action Cracks in excess of the acceptable condition shall be repaired. Remarks Truss uplift may occur when outdoor temperatures are considerably colder than indoor temperatures. It can appear as a minor crack or a larger gap. Repairs should be deferred until such time as the truss returns to its original position. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 159 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 161. Wall and Ceiling Finish 9.6 CONDITION DRYWALL SURFACE BLEMISHES INCLUDING NAIL/SCREW POPS, BLISTERS IN TAPED JOINTS, TROWEL MARKS, EXCESS JOINT COMPOUND AND DENTS OR GOUGES Acceptable Performance/Condition Interior finished drywall (excluding garages and unfinished areas) shall be free from damage (dents and gouges) at the time of the PDI and be installed according to the Ontario Building Code. Blemishes readily noticeable when viewed under normal lighting conditions from a normal viewing position 1,800 mm perpendicular distance from the wall surface are unacceptable. Warranty One-Year – Work and Materials • Nail pops resulting from normal shrinkage of materials due to drying after construction are excluded from the statutory warranty. • Damaged areas of drywall not recorded on the PDI Form are excluded from the statutory warranty unless the homeowner is able to establish that the damage was caused by the builder. Action Only warranted drywall surface blemishes shall be repaired and refinished to match original builder-applied finish as closely as possible. Remarks Identify any damaged drywall surfaces (dents and gouges) on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Surface blemishes in drywall are not unusual at joints and at corners. The repair of surface blemishes resulting from normal shrinkage is at the builder’s discretion and sanding and repainting is not required. Builder’s specific policies with respect to drywall repairs will vary. Often these repairs are best left until the framing has settled. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 160
  • 162. Wall and Ceiling Finish 9.7 CONDITION TEXTURE OF PAINTED GYPSUM WALLBOARD VARIES Acceptable Performance/Condition Variations in the surface texture of finished gypsum wallboard are normal. Warranty None. Action None. Remarks Wall and ceiling surfaces of gypsum wallboard consist of paper and joint compound. These materials accept paint finishes differently. Variations in texture of the final finish may result and are normal. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 161 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 163. Wall and Ceiling Finish 9.8 CONDITION FINISHED SURFACE IS ROUGH Acceptable Performance/Condition Surfaces that are touched during normal use shall be uniformly smooth. Surfaces not touched during normal use shall appear smooth when viewed without magnification, from a minimum distance of 1,500 mm under normal lighting conditions and from a normal viewing position. Warranty One-Year – Work and Materials Action Surfaces not meeting the acceptable condition shall be made smooth and refinished. Remarks The open grain in some wood surfaces tends to show a rough appearance yet feel smooth; this is a natural property of wood and is acceptable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 162
  • 164. Wall and Ceiling Finish 9.9 CONDITION PAINT FINISH IS UNACCEPTABLE Acceptable Performance/Condition A properly painted surface shall be produced on every exposed surface where a painted finish is specified. A properly painted surface shall be assessed by viewing, without magnification, from a minimum perpendicular distance of 1,500 mm under normal lighting conditions and from a normal viewing position. Warranty One-Year – Work and Materials Action Where a properly painted surface is not achieved repairs shall be made. Remarks Natural lighting conditions throughout the day may change the appearance of the properly painted surface. Brush marks are acceptable in cut-in areas and on trim and may vary in appearance with paint type. Repainted areas shall match the original finished surface for colour, sheen and texture as closely as possible. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 163 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 165. Wall and Ceiling Finish 9.10 CONDITION CLEAR INTERIOR FINISHES HAVE DETERIORATED Acceptable Performance/Condition Clear interior finishes shall not deteriorate to the extent that they expose the substrate beneath. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear is excluded from the statutory warranty. Action Clear finishes not meeting the acceptable performance shall be repaired. Remarks Use of inappropriate household cleaners can sometimes contribute to discolouration and premature deterioration of finishes. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 164
  • 166. Wall and Ceiling Finish 9.11 CONDITION PAINT IS SPLATTERED ON SURFACES NOT INTENDED TO BE PAINTED Acceptable Performance/Condition Interior surfaces not intended to be painted shall not have paint splatters when viewed under normal lighting conditions from a normal viewing position. Warranty One-Year – Work and Materials Action Surfaces not meeting acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 165 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 167. Wall and Ceiling Finish 9.12 CONDITION WALLCOVERING IS PEELING Acceptable Performance/Condition Wallcoverings shall not be peeling at the time of the PDI. This condition is warranted only where a defect in work or material is demonstrated. Warranty One-Year – Work and Materials • Damage caused by dampness or condensation due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty. • Additions, deletions or alterations by the homeowner are not covered by the statutory warranty. Action Wallcoverings not meeting the acceptable condition shall be repaired. Remarks High humidity levels can create conditions that can cause wallcoverings to peel. Ventilation of rooms and spaces can help control indoor humidity. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 166
  • 168. Wall and Ceiling Finish 9.13 CONDITION PATTERNS IN WALLCOVERING ARE MISMATCHED AT THE EDGES Acceptable Performance/Condition Wallcoverings shall be installed to achieve a generally uniform appearance when viewed under normal lighting conditions and from a normal viewing position, within the manufacturer’s tolerances. Warranty One-Year – Work and Materials • Additions, deletions or alterations by the homeowner are not covered by the statutory warranty. Action Wallcoverings not meeting the acceptable condition shall be repaired. Remarks Some wallcoverings are more difficult to match than others due to pattern, colour and texture. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 167 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 169. Wall and Ceiling Finish 9.14 CONDITION WATER PENETRATION BEHIND CERAMIC TILE AND BATHTUB OR SHOWER ENCLOSURES Acceptable Performance/Condition Joints between ceramic tiles and adjacent surfaces shall prevent water penetration. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance and normal wear and tear is excluded from the statutory warranty. Action Ceramic tile installation not meeting the acceptable performance shall be repaired. Remarks The owner must regularly inspect and maintain the “soft caulked joints” between the ceramic tiles and adjacent surfaces. Grout joints between individual ceramic tiles may deteriorate over time under normal use; periodic maintenance is required. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 168
  • 170. Wall and Ceiling Finish 9.15 CONDITION MILDEW OR FUNGUS IS VISIBLE ON INTERIOR SURFACES Acceptable Performance/Condition Interior surfaces shall be free of visible mildew and fungus at the time of the PDI. This condition is warranted where there is a demonstrated Ontario Building Code violation or defect in work or material supplied by the builder. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violations • Mildew and fungus resulting from improper maintenance and normal wear and tear are excluded from the statutory warranty. Action Interior surfaces not meeting the acceptable condition shall be repaired. Remarks Note any concerns about visible mildew or fungus on the PDI Form to avoid any dispute about whether the condition was caused by improper maintenance or normal wear and tear. Mildew and fungus often occur when indoor humidity levels are high. Ventilation of rooms and spaces can help control indoor humidity. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 169 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 171. Interior Finishing 10.1 CONDITION INTERIOR DOOR IS WARPED Acceptable Performance/Condition Interior doors leading to rooms or spaces shall not permanently warp more than 6 mm beyond the edge of the doorjamb when the door is closed. In the case of double doors, one leaf shall not permanently warp more than 6 mm beyond the face of the adjacent door leaf. Warranty One-Year – Work and Materials • Damage caused by normal shrinkage of materials due to drying after construction is excluded from the statutory warranty. Action Doors not meeting the acceptable condition shall be repaired. Remarks Minor warping is normal. Interior wood doors are a natural product and are affected by changes in indoor relative humidity, which may contribute to the warping of the door. Normal home maintenance includes controlling indoor humidity levels to prevent permanent warping. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 170
  • 172. Interior Finishing 10.2 CONDITION BI-FOLD AND SLIDING DOORS COME OFF TRACKS Acceptable Performance/Condition Bi-fold and sliding doors shall operate freely and remain on their tracks during normal operation. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear or improper maintenance is excluded from the statutory warranty. Action Doors not meeting the acceptable performance shall be repaired. Remarks Confirm proper operation of the doors during the PDI. Defects discovered after the PDI will be covered under the warranty if they result from the builder’s work. However, bi-fold and sliding doors may require adjustment from time to time to maintain alignment and hardware may need to be cleaned and lubricated as part of normal home maintenance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 171 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 173. Interior Finishing 10.3 CONDITION POCKET DOOR RUBS Acceptable Performance/Condition The face of a pocket door shall not rub against the surrounding framing, doorjamb or casing during normal operation. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear and improper maintenance is excluded from the statutory warranty. Action Doors not meeting the acceptable performance shall be repaired. Remarks Confirm proper operation of interior doors during the PDI. Defects discovered after the PDI will be covered under the statutory warranty if they result from the builder’s work. Some pocket doors require the use of guides that are designed to rub across the face of the door during normal operation and may mark the door; this is acceptable. Pocket doors may require adjustment from time to time and hardware may need to be cleaned and lubricated. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 172
  • 174. Interior Finishing 10.4 CONDITION DOOR RUBS ON THE DOORJAMB OR DOES NOT LATCH Acceptable Performance/Condition Doors shall operate without rubbing on the doorjamb and latches shall engage with relative ease. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear and improper maintenance is excluded from the statutory warranty. Action Doors and latches not meeting the acceptable performance shall be repaired. Remarks Confirm proper operation of the doors during the PDI. Defects discovered after the PDI will be covered under the statutory warranty if they result from the builder’s work. Slight pressure may be required to engage the latch. Seasonal humidity levels may cause doors and jambs to swell, resulting in temporary rubbing; this is acceptable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 173 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 175. Interior Finishing 10.5 CONDITION WOOD DOOR PANEL HAS SPLIT Acceptable Performance/Condition Cracks, where normal light is visible through the door, are not acceptable. Minor cracks that do not allow light through the door are acceptable. Warranty One-Year – Work and Materials • Damage resulting from normal shrinkage due to drying after construction is excluded from the statutory warranty. Action Door panels not meeting the acceptable performance shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 174
  • 176. Interior Finishing 10.6 CONDITION DOOR DRAGS ON THE FLOOR Acceptable Performance/Condition Doors shall not contact the floor unless the door is specifically designed to do so. Warranty One-Year – Work and Materials • Defects in materials, design and work supplied by the homeowner are excluded from the statutory warranty. Action Doors not meeting the acceptable performance shall be repaired. Remarks Confirm proper operation of the doors during the PDI. Defects discovered after the PDI will be covered under the warranty if they result from the builder’s work. Interior doors are typically undercut to facilitate air movement through the house. See section 8.9 “Inadequate Heating” for space under interior doors. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 175 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 177. Interior Finishing 10.7 CONDITION GAP BETWEEN THE DOOR AND THE DOORJAMB IS NOT UNIFORM Acceptable Performance/Condition The width of the gap may vary on different sides or edges of the door. On any specific side or edge of the door, the door and jamb shall be in general visual alignment; variance in the gap shall not exceed double the narrowest dimension along that side or edge. Warranty One-Year – Work and Materials • Damage resulting from normal shrinkage of materials due to drying after construction is excluded from the statutory warranty. Action Doors not meeting the acceptable performance shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 176
  • 178. Interior Finishing 10.8 CONDITION INTERIOR DOOR SWINGS OPEN OR CLOSES BY ITSELF Acceptable Performance/Condition Interior doors shall be installed sufficiently plumb and square so they do not swing by themselves due to the force of gravity alone. Warranty One-Year – Work and Materials • Damage resulting from alterations, deletions or additions by the homeowner is excluded from the statutory warranty. Action Doors not meeting the acceptable performance shall be repaired. Remarks Confirm proper operation of interior doors during the PDI. Defects discovered after the PDI will be covered under the warranty if they result from the builder’s work. Doors will swing open or closed by the force of gravity if the hinges are not aligned plumb. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 177 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 179. Interior Finishing 10.9 CONDITION DOORS BIND FROM IMPROPERLY INSTALLED HINGES Acceptable Performance/Condition Doors shall not bind on their hinges. Warranty One-Year – Work and Materials Action Doors not meeting the acceptable performance shall be repaired. Remarks Confirm proper operation of the doors during the PDI. Defects discovered after the PDI will be covered under the warranty if they result from the builder’s work. Hinges that are not aligned or are excessively recessed into the jamb or door may cause the door to bind; this is not acceptable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 178
  • 180. Interior Finishing 10.10 CONDITION HINGES ARE PAINTED Acceptable Performance/Condition Unless specified in the Agreement of Purchase and Sale or contract, hinges may be painted. Paint shall not interfere with the proper operation of the hinges. Warranty One-Year – Work and Materials • Damage resulting from alterations, deletions or additions by the homeowner is excluded from the statutory warranty. Action Hinges not meeting the acceptable performance shall be repaired. Remarks It is common to paint hinges the same colour as the doorjamb. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 179 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 181. Interior Finishing 10.11 CONDITION GAPS EXIST BETWEEN STAIR PARTS Acceptable Performance/Condition Stair parts (risers, treads, and stringers), where exposed to view in finished areas, shall be fitted to minimize gaps, having aligned surfaces or be filled with a compatible material to achieve the same result. Warranty One-Year – Work and Materials • Damage caused by normal shrinkage of materials due to drying after construction is excluded from the statutory warranty. Action Stairs not meeting the acceptable condition shall be repaired. Remarks Stair parts do not include applied trim and moulding. See section 10.15 “Joint Quality of Interior Trim and Moulding Work”. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 180
  • 182. Interior Finishing 10.12 CONDITION SQUEAKING STAIR RISER OR TREAD Acceptable Performance/Condition Stair risers and treads shall be free of squeaks caused by loose/inadequately fastened joints. Warranty One-Year – Work and Materials • Squeaks caused by normal shrinkage of materials due to drying after construction, improper maintenance or normal wear and tear to the stair are excluded from the statutory warranty. Action Loose/inadequately fastened risers and treads shall be repaired. Remarks Extended low-humidity indoor environments can cause excessive shrinkage in the wood resulting in loose stair connections. The homeowner must maintain indoor humidity levels to prevent excessive drying of materials. A squeak-free stair may not be attainable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 181 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 183. Interior Finishing 10.13 CONDITION GAPS EXIST BETWEEN RAILING PARTS Acceptable Performance/Condition Railing parts shall be fitted to minimize gaps; structural integrity of the joint shall not be affected by minor gaps. Warranty One-Year – Work and Materials • Gaps resulting from normal shrinkage of materials due to drying after construction are excluded from the statutory warranty. Action Railings not meeting the acceptable condition shall be repaired. Remarks Minor gaps may exist due to different methods of fabrication of the railing. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 182
  • 184. Interior Finishing 10.14 CONDITION STAIR RAILINGS LACK RIGIDITY Acceptable Performance/Condition Stair railings shall be securely constructed in accordance with the Ontario Building Code. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violations Action Stair railings not meeting the acceptable condition shall be repaired. Remarks Even when installed in accordance with the Ontario Building Code, slight movement in stair railings may occur under normal use and is acceptable. The selection of materials and the design of the stair railing can affect rigidity. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 183 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 185. Interior Finishing 10.15 CONDITION JOINT QUALITY OF INTERIOR TRIM AND MOULDING WORK Acceptable Performance/Condition Joints in trim, where exposed to view, shall be tightly fitted and have aligned surfaces or be filled with a compatible material to achieve the same result; cracks in excess of 1.5 mm are not acceptable. Warranty One-Year – Work and Materials • Minor gaps caused by normal shrinkage of materials due to drying after construction are excluded from the statutory warranty. Action Joints not meeting the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 184
  • 186. Interior Finishing 10.16 CONDITION NAILHEADS AND FASTENERS ARE NOT PROPERLY SET OR FILLED Acceptable Performance/Condition Nailheads and fasteners shall not protrude above the surface. Where nailheads and fasteners have been set below the surface they shall be filled with compatible filler unless designed otherwise. Filler may be noticeable under normal lighting conditions. Warranty One-Year – Work and Materials Action Nailheads and fasteners not meeting the acceptable condition shall be repaired. Remarks This does not apply in unfinished rooms or spaces. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 185 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 187. Interior Finishing 10.17 CONDITION INTERIOR TRIM IS SPLIT Acceptable Performance/Condition Trim shall not have visible splits. Warranty One-Year – Work and Materials • Damage caused by normal shrinkage of materials due to drying after construction is excluded from the statutory warranty. Action Trim not meeting the acceptable condition shall be repaired. Remarks Filler may be used to repair splits. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 186
  • 188. Interior Finishing 10.18 CONDITION HAMMER MARKS ARE VISIBLE ON TRIM Acceptable Performance/Condition Interior finished trim shall be free from visible hammer marks at the time of the PDI. Warranty One-Year – Work and Materials Action Trim not meeting the acceptable condition shall be repaired. Remarks Damaged interior finished trim not identified on the PDI Form may be excluded from the statutory warranty, unless the homeowner is able to establish that the damage was caused by the builder. Repaired areas shall match the original finished surface for colour, sheen and texture as closely as possible. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 187 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 189. Interior Finishing 10.19 CONDITION RESIN BLEEDING THROUGH PAINTED FINISH Acceptable Performance/Condition Resin shall not bleed through painted finish on trim. Warranty One-Year – Work and Materials Action Painted finishes not meeting the acceptable condition shall be repaired. Remarks The extent of resin bleeding, while a natural characteristic of wood, can be controlled. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 188
  • 190. Interior Finishing 10.20 CONDITION WALL AREA AROUND COLD ROOM DOOR IS UNFINISHED Acceptable Performance/Condition Where the cold room is located in an unfinished basement, wall finish around the door is not required. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violations • Damage resulting from alterations, deletions or additions made by the homeowner is excluded from the statutory warranty. Action Where the wall finish is not installed, no action is required. Remarks The door frame must be secured to operate properly and be installed to meet the Ontario Building Code requirements for insulation, air and vapour barriers and weatherstripping. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 189 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 191. Cabinets and Countertops 11.1 CONDITION GAP BETWEEN CABINETS AND CEILINGS OR WALLS Acceptable Performance/Condition Cabinets shall be fitted to each other. Where cabinets abut walls and ceilings, visible gaps in excess of 3 mm are not acceptable. Warranty One-Year – Work and Materials • Damage resulting from normal shrinkage of materials due to drying after construction is excluded from the statutory warranty. Action Cabinets not meeting the acceptable condition shall be repaired. Remarks It is common to have gaps where cabinets meet different materials. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 190
  • 192. Cabinets and Countertops 11.2 CONDITION CABINETS DO NOT LINE UP WITH EACH OTHER Acceptable Performance/Condition Cabinets shall be aligned with adjacent cabinets and filler panels on the same level to provide a generally uniform appearance when viewed from a normal viewing position. Warranty One-Year – Work and Materials • Damage due to normal wear and tear is excluded from the statutory warranty. Action Cabinets not meeting the acceptable condition shall be repaired. Remarks Cabinet doors can become misaligned through normal use; normal home maintenance includes adjusting the cabinet doors from time to time. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 191 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 193. Cabinets and Countertops 11.3 CONDITION CABINET DOORS AND DRAWER FACES ARE WARPED Acceptable Performance/Condition Cabinet doors and drawer faces shall not permanently warp. Warranty One-Year – Work and Materials Action Cabinet doors and drawer faces not meeting the acceptable condition shall be repaired. Remarks Humidity levels in the home affect cabinet doors and drawer faces made from natural wood products. Some movement can be expected. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 192
  • 194. Cabinets and Countertops 11.4 CONDITION CABINET DOOR OR DRAWER BINDS OR RUBS Acceptable Performance/Condition Cabinet doors and drawers shall be installed so they don’t bind or rub under normal use. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear or improper maintenance is excluded from the statutory warranty. Action Doors and drawers not meeting the acceptable condition shall be repaired. Remarks Cabinet doors and drawers can become misaligned through normal use; normal home maintenance includes adjusting the cabinet doors and drawers from time to time. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 193 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 195. Cabinets and Countertops 11.5 CONDITION CABINET DOORS WILL NOT STAY CLOSED Acceptable Performance/Condition Doors shall stay in position when closed. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear or improper maintenance is excluded from the statutory warranty. Action Doors not meeting the acceptable condition shall be repaired. Remarks Cabinet doors can become misaligned through normal use; normal home maintenance includes adjusting the cabinet doors from time to time. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 194
  • 196. Cabinets and Countertops 11.6 CONDITION LAMINATED COUNTERTOP HAS SWELLED Acceptable Performance/Condition Laminated countertops shall not have localized bumps or swells at the time of the PDI. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance is excluded from the statutory warranty. Action Countertops not meeting the acceptable condition shall be repaired. Remarks Damaged countertops not identified on the PDI Form may be excluded from the statutory warranty, unless the homeowner is able to establish that the damage was caused by the builder. Countertops are susceptible to damage from standing water. Care must be taken to ensure that countertops are kept free of standing water at joints and openings at sinks and faucets. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 195 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 197. Cabinets and Countertops 11.7 CONDITION LAMINATED COUNTERTOP IS DELAMINATED Acceptable Performance/Condition The surface of laminated countertops shall not delaminate. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear and improper maintenance is excluded from the statutory warranty. Action Countertops not meeting the acceptable condition shall be repaired. Remarks Delamination can be caused by excessive heat from appliances and cooking equipment. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 196
  • 198. Cabinets and Countertops 11.8 CONDITION CRACKS IN COUNTERTOP SURFACES Acceptable Performance/Condition Countertop surfaces exposed to view shall be free from cracks at the time of the PDI. Joints are not considered to be cracks. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear is excluded from the statutory warranty. Action Countertops not meeting the acceptable condition shall be repaired. Remarks Damaged countertops not identified on the PDI Form may be excluded from the statutory warranty, unless the homeowner is able to establish that the damage was caused by the builder. Manufactured solid-surface countertops can be brittle and damaged by impact. Care should be taken when cleaning or servicing to prevent cracking or chipping. Sitting or dropping heavy objects on the countertop can create excessive loads that can cause cracking. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 197 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 199. Cabinets and Countertops 11.9 CONDITION SCRATCHES/CHIPS ON COUNTERTOPS Acceptable Performance/Condition Countertop surfaces exposed to view shall be free from visible damage at the time of the PDI. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear is excluded from the statutory warranty. Action Visible damage shall be repaired. Remarks Damaged countertops not identified on the PDI Form may be excluded from the statutory warranty, unless the homeowner is able to establish that the damage was caused by the builder. Maintain countertop surfaces in accordance with the manufacturer’s instructions. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 198
  • 200. Flooring 12.1 CONDITION TRANSITION BETWEEN DIFFERENT TYPES OF FLOORING IS NOT FLUSH Acceptable Performance/Condition An abrupt change in height where different floor finishes abut is acceptable provided the transition is suitably eased (see Remarks). Warranty One-Year – Work and Materials Action Where the acceptable performance has not been met, repairs shall be made. Remarks The subfloor provides the even base on which all finished flooring materials are installed. Changes in height between different flooring materials are caused by material thickness and/or installation methods. Standard practice (unless discussed prior to construction and specified in the Agreement of Purchase and Sale or contract) is to install a transition strip of a material such as wood, metal or marble to ease the change in height. These transition strips do not constitute a tripping hazard and may be used at the builder’s discretion. Transition strips may vary in material, colour, grain and/or dimension. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 199 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 201. Flooring 12.2 CONDITION FLOOR IS UNEVEN Acceptable Performance/Condition Applied finished flooring shall be installed without visible ridges or depressions. Where visible ridges or depressions occur, the variation from the specified plane shall not exceed ±6 mm. Warranty One-Year – Work and Materials • Ridges and depressions caused by normal shrinkage of materials are excluded from the statutory warranty. Action Visible ridges or depressions exceeding the acceptable condition shall be repaired. Remarks The homeowner must maintain finished flooring in accordance with manufacturer’s recommendations and prevent the accumulation of water on flooring. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 200
  • 202. Flooring 12.3 CONDITION PATTERN OF FINISHED FLOORING IS OUT OF ALIGNMENT WITH ADJACENT WALL SURFACES Acceptable Performance/Condition Finished flooring shall be installed in general visual alignment with adjacent wall surfaces. Variation greater than 12.5 mm in 1,800 mm is not acceptable when visible in a room used for its intended purpose. Warranty One-Year – Work and Materials Action Finished flooring not meeting the acceptable condition shall be repaired. Remarks This does not apply to angled or curved walls or flooring not designed to be aligned. The method of repair will vary with the type of finished flooring installed. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 201 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 203. Flooring 12.4 CONDITION CARPET SEAM IS VISIBLE Acceptable Performance/Condition Carpet seams shall be installed with the backing tightly fitted in accordance with the manufacturer’s specifications. Warranty One-Year – Work and Materials • Damaged carpet seams resulting from normal wear and tear or improper maintenance are excluded from the statutory warranty. Action Carpet seams not meeting the acceptable condition shall be repaired. Remarks Identify any concerns about visible carpet seams on the PDI Form to avoid any suggestion that the problem is one of normal wear and tear. Visibility of carpet seams will vary with type of carpet and varying lighting conditions. Although the backing may be tightly fitted, a seam may remain visible; this is acceptable. Where carpets must be cut to execute floor repairs, seams in the repair area may be more visible. Location of carpet seams may vary due to predetermined manufactured widths and installation restrictions and are discretionary. Seams around pickets and end caps on stairs are often visible. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 202
  • 204. Flooring 12.5 CONDITION CARPET IS LOOSE OR STRETCHING HAS OCCURRED Acceptable Performance/Condition Carpeting shall be installed in accordance with the manufacturer’s specifications to prevent loosening at edges, separation from its point of attachment and to minimize stretching under normal use. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance, normal wear and tear, or dampness or condensation due to failure of the homeowner to maintain adequate ventilation is excluded from the statutory warranty. Action Carpet not meeting the acceptable condition shall be repaired. Remarks Carpets should be maintained in accordance with manufacturer’s recommendations. The use of inappropriate cleaning equipment can damage carpet material. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 203 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 205. Flooring 12.6 CONDITION SPOTS OR FADING ON CARPET Acceptable Performance/Condition Carpet shall be free from spots and faded areas. Warranty One-Year – Work and Materials • Spots or faded areas in carpet resulting from normal wear and tear or improper maintenance are excluded from the statutory warranty. Action Spotted or faded carpet recorded on the PDI Form will be repaired. If not noted on the PDI Form, the homeowner must establish that the damage was caused by the builder. Remarks Identify any damaged carpeting at the PDI to avoid any dispute about whether the damage was caused by the builder. Repaired area may be visible as a result of variable lighting conditions or different material dye lot. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 204
  • 206. Flooring 12.7 CONDITION CARPET NOT UNIFORM IN COLOUR Acceptable Performance/Condition Within a room or defined area, carpet shall be uniform in colour, texture and pattern when viewed under normal lighting conditions. Carpet pieces in the same room or defined area shall be installed with the pile oriented in the same direction. Minor variation between dye lots is acceptable. Warranty One-Year – Work and Materials Action Carpet not meeting the acceptable condition shall be repaired. Remarks Slight variation in colour may occur due to different lighting effects and at transitions between rooms or areas. Doorways and thresholds are acceptable locations where pile direction may change. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 205 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 207. Flooring 12.8 CONDITION CARPET HAS DARK STAINS AROUND PERIMETER OF ROOMS AND AT HEATING REGISTERS Acceptable Performance/Condition Dark stains on carpet around room perimeters and at heating registers, commonly called “carbon black”, are an occupant use and house location issue. Sources of carbon rarely relate to work and material supplied by the builder. Warranty None. • Stains resulting from normal wear and tear or improper maintenance are excluded from the statutory warranty. Action The homeowner shall ensure that furnaces, fireplaces, and other combustion appliances within the home are not leaking products of combustion. Remarks Dark staining often results from airborne carbon material settling out on synthetic or magnetic surfaces such as televisions screens, carpets and magnetic seals on refrigerators. Burning scented candles contributes to carpet staining. Light-coloured synthetic carpets accentuate this condition. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 206
  • 208. Flooring 12.9 CONDITION HOLLOW AREAS IN UNDERPAD BELOW CARPET SURFACE Acceptable Performance/Condition Carpet underpad shall provide a continuous surface of support for the carpet. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear, such as furniture loads that may cause local depressions, is excluded from the statutory warranty. Action Hollow areas in underpad shall be repaired. Remarks Carpet underpad is often omitted at the base of stair pickets and nosings. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 207 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 209. Flooring 12.10 CONDITION PROTRUSIONS APPEAR ON THE SURFACE OF RESILIENT FLOORING WITHOUT BREAKING THROUGH Acceptable Performance/Condition Finished surface of flooring shall be free of visible protrusions (bumps, fasteners, telegraphing) that deform the surface of the flooring when viewed under normal lighting conditions (not reflected light) from a normal standing position. Warranty One-Year – Work and Materials Action Visible protrusions in the flooring shall be repaired. Remarks Reflected light, particularly from large windows, exaggerates any irregularity in the floors and should not be considered normal lighting. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 208
  • 210. Flooring 12.11 CONDITION RESILIENT SHEET FLOORING IS LOOSE Acceptable Performance/Condition Resilient sheet flooring shall not come unglued from the substrate. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance is excluded from the statutory warranty. Action Flooring not meeting the acceptable condition shall be repaired. Remarks The homeowner must maintain the flooring in accordance with the manufacturer’s instructions. Excessive water or heat can adversely affect the glue joint. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 209 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 211. Flooring 12.12 CONDITION RESILIENT FLOORING JOINTS NOT TIGHT Acceptable Performance/Condition Resilient flooring shall be installed with no visible gaps in the joints when viewed under normal lighting conditions in a standing position. Warranty One-Year – Work and Materials • Gaps in joints resulting from inappropriate use or maintenance procedures cannot be considered for the statutory warranty. Action Visible gaps not meeting the acceptable condition shall be repaired in accordance with the manufacturer’s specifications. Remarks The visibility of gaps is dependent on a number of factors including texture, pattern, colour, type of resilient material, and lighting. Reflected light, particularly from large windows, exaggerates any irregularity in the floors and should not be considered normal lighting. Joint filler recommended by the flooring manufacturer may be used to fill gaps between seams of sheet flooring. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 210
  • 212. Flooring 12.13 CONDITION BUBBLES APPEAR ON VINYL FLOORING SURFACE Acceptable Performance/Condition Vinyl flooring shall be free from bubbles that cause surface deformities visible from a normal viewing position, under normal lighting conditions without magnification by reflected light. Warranty One-Year – Work and Materials • Bubbles caused by normal wear and tear or improper maintenance are excluded from the statutory warranty. Action Vinyl flooring not meeting the acceptable condition shall be repaired. Remarks As part of repair procedures, vinyl material may be punctured to remove the trapped air. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 211 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 213. Flooring 12.14 CONDITION PATTERNS ON SHEET VINYL FLOORING ARE NOT ALIGNED ACROSS SEAMS Acceptable Performance/Condition Flooring shall be installed to achieve pattern alignment within the manufacturer’s tolerance. Warranty One-Year – Work and Materials Action Flooring not meeting the acceptable condition shall be repaired. Remarks Manufacturer’s tolerances for alignment may vary with patterns, textures and colour of material. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 212
  • 214. Flooring 12.15 CONDITION RESILIENT (FLEXIBLE) FLOOR TILE IS LOOSE Acceptable Performance/Condition Resilient floor tiles shall be securely bonded to the substrate. Warranty One-Year – Work and Materials • Tiles that become detached as a result of improper maintenance, physical damage or moisture, normal wear and tear and chemical contamination cannot be considered for the statutory warranty. Action Only warranted floor tiles that become loose shall be repaired. Remarks The homeowner must maintain tiles in accordance with manufacturer’s written instructions. Shade variations within specified colours in replacement tiles are acceptable. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 213 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 215. Flooring 12.16 CONDITION PATTERNS OR CORNERS OF RESILIENT FLOOR TILE ARE MISALIGNED Acceptable Performance/Condition Resilient floor tiles shall be installed with tight joints to provide a generally uniform appearance throughout the room or defined area when viewed under normal lighting conditions from a normal viewing position. Warranty One-Year – Work and Materials Action Flooring not meeting the acceptable condition shall be repaired. Remarks Alignment of patterns or corners may vary with tile dimensions, shape, texture and colour of material. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 214
  • 216. Flooring 12.17 CONDITION YELLOWING APPEARS ON SURFACE OF VINYL FLOORING Acceptable Performance/Condition Sheet vinyl flooring shall be installed in accordance with the manufacturer’s specifications. Warranty One-Year – Work and Materials • Yellowing due to improper maintenance or to additions, deletions, or alterations by the homeowner is excluded from the statutory warranty. Action Vinyl flooring not meeting the acceptable condition shall be repaired. Remarks The use of inappropriate cleaning materials or coverings, such as latex-backed carpets, may cause discolouration of the flooring. Direct sunlight naturally causes general yellowing over time and is normal. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 215 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 217. Flooring 12.18 CONDITION DYE LOT VARIATIONS IN VINYL FLOORING Acceptable Performance/Condition Within a room or defined area, resilient flooring shall be uniform in colour, texture and pattern when viewed under normal lighting conditions. Minor variation between dye lots is acceptable. Warranty One-Year – Work and Materials Action Resilient flooring not meeting the acceptable condition shall be repaired. Remarks Slight variation in colour may occur due to different lighting effects and pattern. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 216
  • 218. Flooring 12.19 CONDITION VARIATION IN COLOUR OCCURRING DURING REPAIR OF VINYL FLOORING Acceptable Performance/Condition Shade variations between existing material and repaired areas are acceptable within specified colours when viewed from a normal viewing position. Warranty One-Year – Work and Materials Action Shade variations greater than the acceptable condition shall be repaired. Remarks Variation between dye lots within a specified colour or pattern is normal. Spare original material may be left in the residence for future repairs at the builder’s discretion. Where a dye lot match is unavailable, material may be removed and used for repair from another inconspicuous location. Builder’s policies may vary. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 217 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 219. Flooring 12.20 CONDITION CRACKS DEVELOPING BETWEEN STRIPS OF HARDWOOD OR PARQUET FLOORING Acceptable Performance/Condition Cracks resulting from joints that remain open in excess of 2 mm over the length of the strip are not acceptable. Warranty One-Year – Work and Materials • Cracks resulting from normal shrinkage of materials due to drying after construction, damage caused by normal wear and tear or improper maintenance is excluded from the statutory warranty. Action Cracks greater than the acceptable condition shall be repaired. Remarks Hardwood and parquet flooring are natural wood products and therefore are highly susceptible to changes in indoor relative humidity, which may cause dimensional changes in the flooring material. To determine warrantability, the width of the crack should be measured during both the heating and cooling seasons. The homeowner has a responsibility to maintain indoor humidity levels through humidification, ventilation, air conditioning or dehumidification to prevent permanent, irreversible damage. A hygrometer can be used to monitor indoor humidity levels. Areas around heat registers and those exposed to concentrated sunlight may be more susceptible. Wood filler may be used for repairs. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 218
  • 220. Flooring 12.21 CONDITION STRIP HARDWOOD FLOORING IS CUPPED (HIGH EDGES) Acceptable Performance/Condition Strip hardwood flooring shall be installed without cupping. Warranty One-Year – Work and Materials • Damage caused by improper maintenance is excluded from the statutory warranty. • Cupping caused by excessive humidity due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty. Action One complete heating and cooling season should be allowed as the problem may remedy itself. Cupping identified at the time of the PDI shall be repaired. Cupping that occurs after the PDI and is proven to result from defective work or materials shall be repaired. Remarks Identify any damaged hardwood flooring on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Cupping of hardwood strip flooring results from excessive moisture when the humidity below the finished flooring material is substantially higher than above. The homeowner has a responsibility to maintain indoor humidity levels through humidification, ventilation, air conditioning or dehumidification to prevent permanent, irreversible damage. A hygrometer can be used to monitor indoor humidity levels. The immediate sanding of a cupped floor without first allowing it to correct itself may cause even more damage. This condition commonly occurs when houses do not have adequate ventilation and can, under certain circumstances, result from defects in work or materials. See Appendix A2 “Moisture and Wood Floors” for more information. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 219 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 221. Flooring 12.22 CONDITION THE SURFACE OF ONE STRIP OF HARDWOOD OR PARQUET FLOORING IS HIGHER THAN ANOTHER Acceptable Performance/Condition Strip hardwood flooring or parquet flooring shall be installed to provide a surface where adjacent strips have no more than a 2 mm difference in elevation. Warranty One-Year – Work and Materials Action Flooring not meeting the acceptable performance shall be repaired. Remarks Wood is a natural product and variation in colour and grain pattern from one piece of flooring to another is normal and may exaggerate the appearance of the condition. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 220
  • 222. Flooring 12.23 CONDITION FLOOR FINISH ON WOOD FLOORING IS NOT UNIFORM Acceptable Performance/Condition Floor finish shall provide a visible uniform surface when viewed without magnification from a normal viewing position. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear is excluded from the statutory warranty. Action Hardwood flooring surfaces not uniform in appearance shall be repaired. Remarks Wood is a natural product and variation in colour and grain pattern from one piece of flooring to another is normal. The open grain in some wood surfaces tends to show a rough appearance, however this is a natural property of wood and is acceptable. Reflected light, particularly from large windows, magnifies any irregularity in the floors and should not determine acceptance. This applies to both pre-finished and site-applied wood flooring. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 221 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 223. Flooring 12.24 CONDITION FINISH ON WOOD FLOORING HAS BLISTERED, BUBBLED, OR PEELED RESULTING IN DETACHMENT OF FINISH Acceptable Performance/Condition Site-applied or factory-applied finish on hardwood flooring shall not blister, bubble or peel when properly maintained and used under normal conditions. Warranty One-Year – Work and Materials • Damage noted on the PDI Form will be repaired. If not noted, the homeowner must establish that the damage was caused by the builder. Damage caused by normal wear and tear or improper maintenance is excluded from the statutory warranty. Action Defective finished surfaces shall be repaired. Remarks Identify any damaged hardwood flooring on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Isolated air bubbles not resulting in detachment of the finish are acceptable. Colour variation in the wood may cause the area of repair to be visible under normal lighting conditions, even when the repair is undertaken in accordance with a manufacturer’s recommendations. Wood is a natural product and variation in colour and grain pattern from one piece of flooring to another is normal. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 222
  • 224. Flooring 12.25 CONDITION CROWNING OF STRIP HARDWOOD FLOORING HAS OCCURRED (CENTRE OF STRIP IS HIGHER THAN EDGES) Acceptable Performance/Condition Strip hardwood flooring shall be installed without crowning. Warranty One-Year – Work and Materials • Damage caused by improper maintenance and excessive humidity due to failure by the homeowner to maintain adequate ventilation is excluded from the statutory warranty. Action Crowning of hardwood flooring identified on the PDI shall be repaired. If not identified, the homeowner must establish that the damage was caused by the builder. Remarks Identify any damaged hardwood flooring on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Crowning of hardwood strip flooring results from the surface of the flooring being exposed to excessive moisture. This condition commonly develops when houses do not have adequate ventilation or the surface is exposed to water. The homeowner has a responsibility to maintain indoor humidity levels through humidification, ventilation, air conditioning or dehumidification to prevent permanent, irreversible damage. A hygrometer can be used to monitor indoor humidity levels. Never damp mop hardwood flooring. See Appendix A2 “Moisture and Wood Floors” for more information. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 223 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 225. Flooring 12.26 CONDITION WOOD FLOORING BUCKLES AND DETACHES FROM SUBSTRATE Acceptable Performance/Condition Hardwood flooring shall be firmly fastened to the substrate in accordance with manufacturer’s specifications. Warranty One-Year – Work and Materials • Buckling caused by excessive humidity due to failure by the homeowner to maintain adequate ventilation or improper maintenance is excluded from the statutory warranty. Action Only warranted loose hardwood flooring shall be repaired. Remarks The homeowner has a responsibility to maintain indoor humidity levels through humidification, ventilation, air conditioning or dehumidification to prevent permanent, irreversible damage. A hygrometer can be used to monitor indoor humidity levels. Wood flooring shall be installed to accommodate normal expansion and contraction. See Appendix A2 “Moisture and Wood Floors” for more information. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 224
  • 226. Flooring 12.27 CONDITION KNOTS AND COLOUR VARIATION IN STRIP WOOD FLOORING Acceptable Performance/Condition Knots or colour variation are acceptable within different grades of flooring. Warranty One-Year – Work and Materials Action Flooring not meeting the acceptable condition shall be replaced. Remarks Knots and colour variation are natural characteristics of wood and are acceptable within the specified grade. The homeowner’s area rugs, latex-backed material or any coverings over floors may result in colour variation of the floor. Natural lighting will also cause discolouration. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 225 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 227. Flooring 12.28 CONDITION SPLINTERS OCCUR IN STRIP WOOD FLOORING Acceptable Performance/Condition Finished flooring shall have a surface that is smooth, even and free from splinters. Warranty One-Year – Work and Materials • Splinters resulting from improper maintenance are excluded from the statutory warranty. Action Splintered flooring shall be repaired. Remarks Splinters should not occur under normal usage conditions. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 226
  • 228. Flooring 12.29 CONDITION “STICKER BURN” APPEARS ON SURFACE OF STRIP FLOORING Acceptable Performance/Condition The surface of strip wood flooring shall be free from discolouration caused by manufacturing or storage procedures within the different grade of flooring specified. Warranty One-Year – Work and Materials Action Discoloured pieces of flooring shall be repaired or replaced where disallowed by the grade. Remarks “Sticker burn” is discolouration across the width of the board caused by the sticks used between the lumber during the drying process. Sticker burn is acceptable within some different specified grades. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 227 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 229. Flooring 12.30 CONDITION CERAMIC/PORCELAIN TILE, MARBLE OR STONE FLOORING IS BROKEN OR LOOSE (INCLUDING MARBLE TRANSITIONS) Acceptable Performance/Condition Ceramic/porcelain tile, marble or stone flooring shall be installed to prevent it from cracking or coming loose from the substrate. In rooms or areas where the flooring must provide a degree of water resistance required by the Ontario Building Code, cracked or loose flooring allowing water to penetrate is not acceptable. Warranty One-Year – Work and Materials • Where floors are not required to provide water resistance, cracked or loose tiles resulting from normal shrinkage of materials due to drying after construction are excluded from the statutory warranty. • Damage caused by normal wear and tear or improper maintenance is excluded from the statutory warranty. Action Flooring not meeting the acceptable condition shall be repaired. Remarks Identify any damaged ceramic/porcelain tile on the PDI Form to avoid any dispute about whether the damage was caused by the builder. Variations between dye lots of similar materials within a specified colour or pattern are normal and acceptable provided they are not readily visible. Slight variations in grout colour are to be expected when making repairs. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 228
  • 230. Flooring 12.31 CONDITION CRACKS APPEARING IN GROUTING OF CERAMIC TILE JOINTS OR AT JUNCTIONS WITH OTHER MATERIALS SUCH AS BATHTUBS Acceptable Performance/Condition Hairline cracks in grout are common, however, loose or missing grout is unacceptable. Warranty One-Year – Work and Materials • Cracks resulting from normal shrinkage of materials due to drying after construction are excluded from the statutory warranty. Action Cracks not meeting the acceptable condition shall be repaired. Remarks Slight variations in grout colour are to be expected when making repairs. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 229 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 231. Flooring 12.32 CONDITION ADJACENT MARBLE UNITS OR CERAMIC TILE SURFACES INSTALLED AT DIFFERENT ELEVATIONS Acceptable Performance/Condition Adjacent marble units and/or adjacent ceramic tiles shall be installed generally flush, taking into account the texture and intended aesthetic application of the finished surface. Warranty One-Year – Work and Materials Action Tile installations not meeting the acceptable performance shall be repaired. Remarks Some floor tiles are designed with irregular finished surfaces, which may exaggerate the aesthetic appearance of the condition. Variations in grout and tile colour are to be expected when making repairs. Variation between dye lots of similar materials within a specified colour or pattern is normal. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 230
  • 232. Flooring 12.33 CONDITION GROUT IS NOT A UNIFORM COLOUR Acceptable Performance/Condition In a room or defined area the colour of grouted joints between ceramic tiles shall appear generally uniform under normal lighting conditions and from a normal viewing position. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance and normal wear and tear is excluded from the statutory warranty. Action Grout joints not meeting the acceptable condition shall be repaired. Remarks Minor variation in grout joint colour is normal. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 231 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 233. Chimneys and Fireplaces 13.1 CONDITION JOINT OR CRACK IN CHIMNEY CAP ALLOWS WATER LEAK Acceptable Performance/Condition Chimney caps shall be waterproof. Warranty Two-Year – Building Envelope Water Penetration Action Chimney caps not meeting the acceptable performance shall be repaired. Remarks Masonry chimney cap cracks may develop due to the severe conditions caps must endure. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 232
  • 234. Chimneys and Fireplaces 13.2 CONDITION ROOF FLASHING LEAKS AT CHIMNEY Acceptable Performance/Condition Roof flashings at chimneys shall not leak under normal weather conditions. Warranty Two-Year – Building Envelope Water Penetration • Damage resulting from improper maintenance is not covered by the statutory warranty. Action Roof flashings not meeting the acceptable performance shall be repaired. Remarks Ice buildup around chimneys can contribute to water penetration. Keeping roofs clear of heavy snow and ice is important to help prevent ice buildup. Normal home maintenance should include professional removal of heavy buildups of ice and snow. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 233 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 235. Chimneys and Fireplaces 13.3 CONDITION BRICKS BREAKING UP ON SURFACE OF CHIMNEY Acceptable Performance/Condition Bricks used for chimneys shall not deteriorate or become displaced. Warranty One-Year – Work and Materials Two-Year – Cladding Detachment, Displacement or Deterioration Action Bricks not meeting the acceptable performance shall be repaired. Remarks Moisture migration into the chimney brick can contribute to premature deterioration. Chimney cap overhangs are critical to protect the chimney from weather. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 234
  • 236. Chimneys and Fireplaces 13.4 CONDITION CHIMNEY SERVING SOLID-FUEL-BURNING (WOOD, PELLET, ETC.) APPLIANCE DOES NOT DRAW PROPERLY Acceptable Performance/Condition Chimneys serving solid-fuel-burning appliances shall be installed in accordance with the Ontario Building Code. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violations • Damage resulting from improper maintenance or additions, deletions or alterations made by a homeowner is excluded from the statutory warranty. Action Chimneys not meeting the acceptable performance shall be repaired. Remarks Chimneys may not draw properly if: • adjacent buildings, trees or high winds create downdrafts • the chimney is plugged • the chimney is cold • the combustion air supply for the appliance is restricted. Opening a window may help the chimney draw properly. Inspecting and cleaning the chimney is part of regular home maintenance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 235 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 237. Chimneys and Fireplaces 13.5 CONDITION FIREPLACE FIREBOX PAINT COLOUR CHANGED Acceptable Performance/Condition Fireplace firebox paint colour may change with time and use. Warranty None. Action None. Remarks Even though the firebox paint is designed for high temperatures, the paint may change colour. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 236
  • 238. Chimneys and Fireplaces 13.6 CONDITION FIREBRICK IS BROKEN Acceptable Performance/Condition Firebrick shall not break during the statutory warranty period. This condition is warranted only where a defect in work or material is demonstrated. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance or normal wear and tear is not covered by the statutory warranty. Action Firebricks not meeting the acceptable performance shall be repaired. Remarks Firebrick provides the primary heat protection in the firebox. Overheating can cause premature cracking. Firebricks can be damaged by impact. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 237 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 239. Garages and Exterior 14.1 CONDITION GARAGE FLOOR HAS HEAVED OR SETTLED Acceptable Performance/Condition Non-structural poured concrete garage floors supported by grade shall not heave or settle to produce a negative slope into the garage. Warranty One-Year – Work and Materials Action Repair slab to provide drainage in accordance with the Ontario Building Code. Remarks Repair may involve modifications to either the garage floor or supporting sub-grade. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 238
  • 240. Garages and Exterior 14.2 CONDITION CONCRETE GARAGE FLOOR IS CRACKED Acceptable Performance/Condition Cracks resulting from normal shrinkage are acceptable; crack width in excess of 6 mm is not acceptable. Warranty One-Year – Work and Materials • Cracks resulting from normal shrinkage of materials caused by drying after construction are excluded from the statutory warranty. Action Cracks in excess of the acceptable condition shall be repaired. Remarks Concrete floors naturally crack during curing due to shrinkage. Actual crack width shall be determined using a wire feeler gauge* inserted inside the crack. Where repairs are necessary, colour and/or texture of repair materials may not match the surrounding concrete. * Because it is of a manufactured, set size, an Allen Wrench/Key may be used as a wire feeler gauge. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 239 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 241. Garages and Exterior 14.3 CONDITION NO REINFORCING IN GARAGE SLAB Acceptable Performance/Condition Unless the slab is specifically intended and designed to be a structural slab, reinforcing or mesh is not required. Warranty One-Year – Work and Materials Seven-Year – Major Structural Defect Action Where a structural slab is not reinforced as required by the design, repairs shall be made; otherwise no action is required. Remarks Concrete slabs in garages shall conform to Section 9.16 of the Ontario Building Code. Reinforcing of concrete slabs is not usually necessary unless abnormal design or construction conditions are encountered. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 240
  • 242. Garages and Exterior 14.4 CONDITION GARAGE DOORS DO NOT OPERATE PROPERLY Acceptable Performance/Condition Overhead garage doors shall manually operate with relative ease without binding. An automatic garage door opener supplied and installed by the builder shall not interfere with the emergency manual operation of the door. Warranty One-Year – Work and Materials • Damage caused by improper maintenance or additions, deletions or alterations by the homeowner is not covered by the statutory warranty. Action Garage doors not meeting the acceptable performance shall be repaired. Remarks Proper operation of overhead garage doors should be confirmed at the PDI and any malfunction should be noted on the PDI Form to avoid any dispute about whether the damage was caused by the builder. The builder is not responsible for the door operation if the homeowner has installed a garage door opener. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 241 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 243. Garages and Exterior 14.5 CONDITION GARAGE DOORS (VEHICULAR AND MAN-DOORS) ALLOW ENTRANCE OF SNOW OR WATER Acceptable Performance/Condition Garage doors are not required to be weatherstripped and may allow snow and water to enter the garage. Warranty None. Action None. Remarks Unless a garage is constructed by the builder to be used for habitable space, garage doors are not required to be weathertight. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 242
  • 244. Garages and Exterior 14.6 CONDITION WATER ACCUMULATES ON GARAGE FLOOR Acceptable Performance/Condition Provided garage floors are sloped to drain to the exterior, minor variations in the surface of the floor may impede immediate drainage and are acceptable. Warranty One-Year – Work and Materials Action Garage floors not meeting the acceptable condition shall be repaired. Remarks Closed overhead garage doors, stored materials and debris on the floor may impede drainage to the exterior. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 243 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 245. Garages and Exterior 14.7 CONDITION ASPHALT OR CONCRETE DRIVEWAY HAS CRACKED Acceptable Performance/Condition Cracks are acceptable if caused by factors other than a defect in work or materials provided by the builder. Warranty One-Year – Work and Materials • Damage resulting from normal shrinkage of materials caused by drying after construction, improper maintenance, normal wear and tear, subsidence of the land around the building, or alterations, deletions, or additions made by the homeowner is not covered by the statutory warranty. Action Cracks not meeting the acceptable condition shall be repaired. Remarks The condition is warranted where there is a demonstrated defect in work or material supplied by the builder. Cracks may develop in driveways due to environmental conditions, soil settlement, de-icing chemicals, or shrinkage of the asphalt or concrete, and are not warranted in those situations. Heavy loads from large vehicles can damage driveways. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 244
  • 246. Garages and Exterior 14.8 CONDITION DRIVEWAY HAS SETTLED Acceptable Performance/Condition Driveways shall be graded so that water does not accumulate at or near the building. Subsidence in other parts of a driveway is not covered by the statutory warranty. Warranty One-Year – Work and Materials • Subsidence of the land around the building or along utility lines, alterations by the homeowner such as landscaping or improper maintenance is excluded from the statutory warranty. Action Driveways not meeting the acceptable condition shall be repaired. Remarks Disturbed soil will naturally consolidate and cannot practically be prevented from moving. Frost heaves may also produce seasonal movement where the driveway meets the garage. Heavy loads imposed on a driveway can cause local depressions. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 245 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 247. Garages and Exterior 14.9 CONDITION SOD/SEEDING NOT COMPLETED Acceptable Performance/Condition Sod/seeding shall be installed in conditions conducive to growth, generally within one year of the occupancy of the home or within the time period required by governing municipal agreements or the phasing of the subdivision. Warranty One-Year – Incomplete Work One-Year – Work and Materials • Sod/seeding that fails due to improper maintenance is excluded from the statutory warranty. Action Builder shall complete sod/seeding installation when conditions conducive to growth exist. The installation of sod/seeding can coincide with subdivision phasing. Remarks Identify any incomplete landscaping (that is the responsibility of the builder) at the PDI. Sod/seeding should only be installed when conditions are conducive to growth, typically mid-spring through mid-fall. The homeowner is responsible to maintain sod/seeding after installation is complete; maintenance requirements may vary. The installation of sod/seeding may be delayed as a result of: • Homes occupied when conditions are not conducive to growth • Phasing of sub-division work • Final grading related to municipal agreements Growing conditions vary according to geographic location. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 246
  • 248. Garages and Exterior 14.10 CONDITION THE SHRUBS, TREE(S), PLANTS, OR SOD HAVE DIED Acceptable Performance/Condition Landscaping plants supplied and installed by the builder shall be alive at the time of the PDI or when installed, whichever is later. Warranty One-Year – Work and Materials Action Landscape planting not meeting the acceptable condition shall be replaced. Remarks Homeowners must water and nurture landscaping plants after installation to ensure growth. Plants that are alive when installed and subsequently die are not the responsibility of the builder. Plants on municipal property such as boulevards and walkways are not covered by the statutory warranty. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 247 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 249. Garages and Exterior 14.11 CONDITION TREE STUMPS HAVE BEEN LEFT ON THE PROPERTY Acceptable Performance/Condition Where the builder is responsible for final grading under the contract and trees have been cut down as part of the construction process, stumps shall be removed. Warranty One-Year – Work and Materials Action Tree stumps not meeting the acceptable condition shall be removed. Remarks Identify any incomplete landscaping (that is the responsibility of the builder) at the PDI. Reference must be made to the Agreement of Purchase and Sale or construction contract in order to determine the scope of the builder’s responsibilities. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.new.on.ca 248
  • 250. Garages and Exterior 14.12 CONDITION WATER PONDING IN SURFACE GRADING OF THE SITE Acceptable Performance/Condition The site shall be graded so that water does not accumulate at or near the building. Backfill against a foundation shall be graded to prevent drainage towards the building after settling. Where no grade is specified for a slope, a minimum gradient of 2% is considered acceptable; sodded or gravelled areas may have a minimum gradient of 1%. Warranty One-Year – Work and Materials One-Year – Ontario Building Code Violations • Subsidence of the land around the building or along utility lines, alterations by the homeowner such as landscaping or improper maintenance is excluded from the statutory warranty. Action Site grading shall meet the acceptable condition by conforming to a municipally approved grading plan, or equivalent, where applicable. After the first year, the homeowner is responsible for maintaining the finished site grading to ensure ponding water does not adversely affect their premises. Remarks Ponding may occur because grading may not always be finished at occupancy. Generally, municipalities control the grading patterns of building sites and builders must comply with approved grading plans for the installation of swales and slopes. Disturbed soil will naturally consolidate and cannot practically be prevented from settling; i.e., settlement of walkways and driveways is not covered by warranty. However, sufficient soil must be placed around the building to ensure acceptable drainage is maintained during the first year after occupancy. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 249 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 251. Garages and Exterior 14.13 CONDITION SETTLING, HEAVING OR SEPARATING OF LANDINGS OR STEPS Acceptable Performance/Condition Stairs and landings supported by a foundation shall not heave, settle or separate from the main building more than 25 mm. Stairs and landings not requiring a foundation are not restricted from movement. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violations • Settlement and subsidence of the land around the building or along utility lines, other than subsidence beneath the footings of the building, is excluded from the statutory warranty. • Damage resulting from normal shrinkage of materials due to drying after construction is not covered by the statutory warranty. Action Stairs, landings and decks not meeting the acceptable performance shall be repaired. Remarks Concrete stairs having not more than two risers, and small wood stairs not attached to the building do not require foundations and are often affected by the settlement of supporting backfill – this is not covered by the statutory warranty. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 250
  • 252. Garages and Exterior 14.14 CONDITION EXTERIOR DECK IS SPRINGY OR SHAKY Acceptable Performance/Condition Exterior decks shall be designed and installed in accordance with the Ontario Building Code. Warranty One-Year – Work and Materials Two-Year – Ontario Building Code Health & Safety Violations Action Decks not meeting the acceptable performance shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 251 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 253. Garages and Exterior 14.15 CONDITION EXTERIOR DECK RAILING IS SHAKY Acceptable Performance/Condition Exterior deck guards shall be designed and installed in accordance with the Ontario Building Code. Warranty Two-Year – Ontario Building Code Health & Safety Violations • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Exterior deck railings and guards not meeting the acceptable performance shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 252
  • 254. Garages and Exterior 14.16 CONDITION DECK BOARD SPACING IS NOT UNIFORM Acceptable Performance/Condition Deck boards forming the walking surface shall be spaced to provide a generally uniform appearance. Warranty One-Year – Work and Materials • Normal shrinkage of materials due to drying after construction is not covered by warranty. Action Deck boards not meeting the acceptable condition shall be repaired. Remarks Spacing between boards may be adjusted during installation to allow for construction variances. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 253 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 255. Garages and Exterior 14.17 CONDITION EXTERIOR WOOD HANDRAILS HAVE SLIVERS Acceptable Performance/Condition Handrail surfaces meant to be touched shall not have slivers that prevent the handrails from being grasped. Warranty One-Year – Work and Materials • Damage resulting from normal wear and tear is excluded from warranty. Action Handrails not meeting the acceptable condition shall be repaired. Remarks This condition is warranted only where there is a demonstrated defect in work or material supplied by the builder. Small slivers can develop from weathering and can be easily removed by sanding as part of normal home maintenance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 254
  • 256. Garages and Exterior 14.18 CONDITION EXTERIOR DECK IS OUT OF LEVEL Acceptable Performance/Condition Exterior decks may slope away from the building a maximum ratio of 50 mm in 3,600 mm to shed water. Warranty One-Year – Work and Materials Action Exterior decks not meeting the acceptable condition shall be repaired. Remarks None. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 255 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 257. Garages and Exterior 14.19 CONDITION FLOOR DECKING BOARDS ARE SPLIT, WARPED OR CUPPED Acceptable Performance/Condition Floor decking boards may split with exposure to the natural environment. Floor decking boards shall be fastened securely to minimize warping and cupping. Warranty One-Year – Work and Materials • Damage resulting from improper maintenance, normal shrinkage of materials due to drying after construction, or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Floor decking boards not meeting the acceptable condition shall be repaired. Remarks Floor decking boards may naturally split with exposure to the elements – the condition cannot reasonably be prevented. The characteristics of some manufactured materials may vary. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 256
  • 258. Garages and Exterior 14.20 CONDITION STAIN COLOUR VARIATIONS ON WOOD DECK Acceptable Performance/Condition Stain on a wood deck shall appear generally uniform in colour. Colour variations are acceptable when changing from the horizontal plane to the vertical plane (i.e., from a vertical guard or fence to a horizontal deck). Warranty One-Year – Work and Materials • Damage resulting from improper maintenance or additions, deletions or alterations made by the homeowner is excluded from the statutory warranty. Action Stain colour not meeting the acceptable performance shall be repaired. Remarks Stain colour will fade with exposure to the elements. Stain colour in areas with intense sun exposure will vary more than areas that have some protection. Wood is a natural material and stain penetration may vary with wood type and grain patterns. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 257 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 259. Garages and Exterior 14.21 CONDITION NAILHEADS STICK UP ON DECK SURFACE Acceptable Performance/Condition Nailheads shall be set generally flush with the adjacent deck surface. Warranty One-Year – Work and Materials • Damage resulting from shrinkage of materials is excluded from the statutory warranty. Action Nailheads not meeting the acceptable performance shall be repaired. Remarks Nailheads on decks will protrude from the surface over time and can be easily reset as part of regular home maintenance. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 258
  • 260. Garages and Exterior 14.22 CONDITION STAINS ON EXTERIOR DECKING FROM NAILHEADS Acceptable Performance/Condition Nails will discolour or rust with exposure to the natural environment. Warranty None. Action None. Remarks Even galvanized nails can discolour over time and may stain adjacent deck surfaces. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 259 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 261. Garages and Exterior 14.23 CONDITION TWISTING OF OPEN-END BEAMS Acceptable Performance/Condition Twisting of visible open-end beams in excess of 13 mm from plumb is not acceptable. Warranty One-Year – Work and Materials • Twisting resulting from normal shrinkage caused by drying after construction is excluded from warranty. Action Open-ended beams twisted more than the acceptable condition shall be repaired. Remarks An open-end beam is a wood beam whose end does not abut another framing member or that terminates in open air. Minor twisting is primarily an aesthetic concern rather than a structural problem. Words in italics are defined in the “Terminology” section on pages 15-17. Notes Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 260
  • 262. Appendices A1 Sources The following sources were consulted in the development of the Guidelines. 1. Ontario Building Code, Ontario Government Bookstore. 2. Canadian Building Digest, National Research Council Canada. 3. Building Technology Best Practice Guide, Canada Mortgage and Housing Corporation. 4. Characteristics of Concrete, Poured Concrete Association/Cement Association of Canada. 5. Ontario New Home Warranties Plan Act and Regulations. 6. Focus: Concrete Masonry Units, Ontario Concrete Block Association. 7. Code and Construction Guide for Housing, Ontario New Home Warranty Program Policies, Ontario New Home Warranty Program. 8. Residential Air System Design Manual, Heating, Refrigerating and Air Conditioning Institute. 9. Architectural Specification Manual, Ontario Painting Contractors Association. 10. Problems, Causes, Cures, National Wood Flooring Association. 11. CAN/CSA-A82.1-M87 “Burned Clay Bricks”, CAN/CSA-A371-94 “Masonry Construction for Buildings”, Canadian Standards Association. 12. 2002 Specification Guide 09300 Tile Installation Manual, Terrazzo, Tile and Marble Association of Canada. A2 Moisture and Wood Floors This information is intended as a guide only. WOOD FLOORING HAS A COMFORT LEVEL, TOO Wood flooring will perform best when the interior environment is controlled to stay within a relative humidity range of 30 to 50 per cent and a temperature range between 15°C and 27°C. Fortunately, that’s about the same comfort range most humans enjoy. The chart below indicates the moisture content wood will likely have at any given combination of temperature and humidity. Note that equilibrium moisture contents in the recommended temperature/humidity range (shaded area) coincide with the 6 to 9 per cent range within which most hardwood flooring is manufactured. Although some movement can be expected even between 6 and 9 per cent, wood can expand and shrink dramatically outside that range. Table 1 MOISTURE CONTENT OF WOOD AT VARIOUS TEMPERATURES AND RELATIVE HUMIDITY READINGS Temperature (Celsius) -2 1.4 2.6 3.7 4.6 5.5 6.3 7.1 7.9 8.7 9.5 10.4 11.3 12.4 13.5 14.9 16.5 18.5 21.0 24.3 26.9 4 1.4 2.6 3.7 4.6 5.5 6.3 7.1 7.9 8.7 9.5 10.4 11.3 12.4 13.5 14.9 16.5 18.5 21.0 24.3 26.9 10 1.4 2.6 3.7 4.6 5.5 6.3 7.1 7.9 8.7 9.5 10.4 11.3 12.4 13.5 14.9 16.5 18.5 21.0 24.3 26.9 15 1.3 2.5 3.6 4.6 5.4 6.2 7.0 7.8 8.6 9.4 10.2 11.1 12.1 13.3 14.6 16.2 18.2 20.7 24.1 26.8 21 1.3 2.5 3.5 4.5 5.4 6.2 6.9 7.7 8.5 9.2 10.1 11.0 12.0 13.1 14.4 16.0 17.9 20.5 23.9 26.6 27 1.3 2.4 3.5 4.4 5.3 6.1 6.8 7.6 8.3 9.1 9.9 10.6 11.7 12.9 14.2 15.7 17.7 20.2 23.6 26.3 32 1.2 2.3 3.4 4.3 5.1 5.9 6.7 7.4 8.1 8.9 9.7 10.5 11.5 12.6 13.9 15.4 17.3 19.8 23.3 26.0 38 1.2 2.3 3.3 4.2 5.0 5.8 6.5 7.2 7.9 8.7 9.5 10.3 11.2 12.3 13.6 15.1 17.0 19.5 22.9 25.6 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 98 Relative Humidity (per cent) Chart taken from National Wood Flooring Association Technical Publication No. A100. Construction Performance Guidelines Second Edition, effective December 1, 2003 261 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 263. Appendices A3 Moisture and Windows This chart identifies the maximum relative humidity for a given inside temperature above which condensation will form on windows. For additional information, see the Canada Mortgage and Housing Corporation’s (CMHC) pamphlet Moisture and Air, Problems and Remedies, available by request from CMHC or at their website www.cmhc-schl.gc.ca Table 2 Inside Temperature 20oC 22oC 24oC Outside MAXIMUM RELATIVE HUMIDITY (%) Temperature SINGLE DOUBLE SINGLE DOUBLE SINGLE DOUBLE (oC) GLASS GLASS GLASS GLASS GLASS GLASS - 35 3 18 3 18 3 18 - 29 5 23 5 22 5 21 - 23 8 27 7 26 6 25 - 18 12 33 11 31 10 29 - 12 17 39 16 37 15 35 -7 24 46 23 44 22 42 -1 34 55 32 52 30 49 A4 Measuring Variation from the Specified Plane Using a Plane of Reference To measure the variation: 1) Place two blocks of equal thickness on either side of the surface you are considering. 2) Stretch a string across the top of the blocks so the string doesn’t sag; the blocks may have to be secured from moving. 3) Measure the difference between the string and the actual surface and subtract the thickness of the blocks. 4) Compare the result with the allowable variation in the Guidelines. Reference Plane (string) Block Block Specified Plane Actual Surface Figure 1. Measuring actual surface variation from a specified plane using a plane of reference. Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 262
  • 264. Appendices A5 How to Conduct a Water Test A water test shall be performed to confirm water leaks, both above and below grade. Above grade the intent is to simulate an average, wind-driven rainfall but should never be done using full pressure in a single-stream or pressure-altering device such as a pressure washer. This can force water through building assemblies and flashings not intended for high-volume or high-pressure water saturation. Below grade the intent is to simulate natural water flow around a foundation caused by rain or snow melting where the water may inadvertently be directed towards the foundation wall. Water penetration is considered to be bulk water coming into the basement or accumulating near the point of entry, or dampness on the wall appearing as a result of the test, but excludes dampness caused by condensation or other causes. Above Grade Use a standard garden hose and sprayer attachment. The sprayer attachment should be set on “shower” or other similar dispersal pattern. Spray the area to be tested for not more than 10 minutes from a minimum distance of 2 m. Have another person checking inside for the point of origin and the length of time it takes for water to appear. Areas to be investigated should be kept dry prior to the test. Below Grade Use a standard garden hose with no attachments. The hose bib should be set at about half flow to simulate melting snow or rainfall. The water from the hose is to be directed along the face of the foundation to allow the water to run parallel to the wall, at grade, finding its own way down the exterior of the wall to the perimeter foundation drains. Run the water for not more than 20 minutes checking periodically for water penetration. Identify the location and the point of entry of any water (crack, tie rod, snap tie, honeycombing) and the length of time it takes for water to appear. Construction Performance Guidelines Second Edition, effective December 1, 2003 263 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 265. Appendices A6 Chipped Clay Bricks The following table is from Canadian Standards Association, CSA A82.1-M87, “Burned Clay Bricks”. Table 3 CLAY BRICK MAXIMUM PERMISSIBLE EXTENT1 OF CHIPPAGE FROM THE EDGES AND CORNERS OF THE FINISHED FACE OR FACES ONTO THE SURFACE Chippage in millimetres Chippage in millimetres (inches) in from (inches) in from Maximum Remaining percentage percentage Type allowed* § Edge Corner allowed* § Edge Corner (1) (2) (3) (4) (5) (6) (7) FBS2 6.35 – 7.94 9.53 – 12.7 0 – 6.35 0 – 9.53 10% or less 90 – 100% (Smooth)† (1/4 – 5/16) (3/8 – 1/2) (0 – 1/4) (0 – 3/8) FBS2 7.94 – 11.1 12.7 – 19.1 0 – 7.94 0 – 12.7 15% or less 85 – 100% (Rough)‡ (5/16 – 7/16) (1/2 – 3/4) (0 – 5/16) (0 – 1/2) * Percentage of exposed brick allowed in the wall with chips measured the listed dimensions in from an edge or corner. † Smooth texture is the unbroken natural die finish. ‡ Rough texture is the finish produced when the face is sanded, combed, scratched, or scarified, or the die skin on the face is entirely broken by mechanical means such as wire cutting or wire brushing. § Of all the units that will be exposed in place, a small percentage of the units may have chips that range in size greater than that allowed for the majority of the units. This special allowed percentage, as shown in the second column from the left, ranges up to 10% for FBS (smooth), and up to 15% for FBS (rough). The rest of the units that will be exposed in place, as shown in the 5th column from the left, just conform to the maximum allowed chippage shown in the 6th and 7th columns from the left. Example: The units to be placed into the wall should be inspected prior to being placed. The FBS (smooth) units will then conform to the requirements of this Table if not more that 10% of the units have edge chips greater than 6.35 mm (1/4") but less than 7.94 mm (5/16") and the remainder of the units, in this example 90% (100% - 10%), do not have edge chips greater than 6.35 mm (1/4") in from the edge or 9.53 mm (3/8") in from the corner. Notes 1. The aggregate length of chips shall not exceed 10% of the perimeter of the face of the brick (CAN/CSA-A82.1-M87, s.7.3). 2. Type FBS brick is the most common type of brick used in residential construction. They are used in exposed exterior and interior masonry walls where wider colour ranges and greater variation in sizes are allowed (CAN/CSA-A82.1-M87, s.4.1.2). For other types of bricks, refer to CAN/CSA-A82.1-M87. With the permission of Canadian Standards Association, material is reproduced from CSA Standard CAN/CSA-A82.1-M87, which is copyrighted by Canadian Standards Association, 178 Rexdale Blvd., Toronto, Ontario, M9W 1R3, www.csa.ca. While use of this material has been authorized, CSA shall not be responsible for the manner in which the information is presented, nor for any interpretations thereof. Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 264
  • 266. Appendices Using a representative sample to determine the percentages of affected bricks in Table 3. A representative sample may be used to determine the percentage of bricks (Columns (2) and (5) in Table 3) that have chips of specified sizes. The representative sample (versus an isolated section of the wall with the chipped brick problem) shall be 1 m x 1 m in size with the centre of the sample located 1.5 m (5') above the foundation in the middle of the wall. If the sample lands on an opening (window, door, etc), it shall be moved horizontally in the direction of the most brick in the sample so a full square metre of brick is sampled. Individual bricks must still meet the maximum chip dimensions in Table 3. Illustrating Brick Chippage These illustrations are colour-coded to help describe the information in Table 3. 90%-100% 85%-100% of the bricks of the bricks can have can have chips up chips up to 3/8" in to 1/2" from the in from corner the corner Smooth Not more Rough Not more Bricks † than 10% Bricks ‡ than 15% of the bricks of the bricks can have can have chips between chips between 3/8"-1/2” 1/2"-3/4" in from in from the corner the corner Not more than 10% 90%-100% of the Not more than 15% 85%-100% of the of the bricks can bricks can have of the bricks can bricks can have have chips that are chips up to 1/4" have chips that are chips up to 5/16" between 1/4"-5/16" in from the edge between 5/16"-7/16" in from the edge in from the edge in from the edge Construction Performance Guidelines Second Edition, effective December 1, 2003 265 For more information, call 1-800-668-0124 or visit www.newhome.on.ca
  • 267. Appendices A7 Industry Agencies The following residential building industry agencies contributed to the development of the Guidelines. Technical Standard Sub-committee of the Ontario Home Builders’ Association/Ontario New Home Warranty Program Liaison Committee Canadian Carpet Institute Ready Mixed Concrete Association of Ontario Canadian Plywood Association Residential Carpentry Contractors Association Canadian Window and Door Manufacturers of Greater Toronto Association Residential Construction Control Council Cement Association of Canada of Central Ontario Concrete Forming Association of Ontario Residential Framing Contractors Association of Metropolitan Toronto & Vicinity Heating, Refrigeration & Air Conditioning Institute Residential Roofing Contractors Association Independent Plumbing & Heating Contractors’ of Greater Metropolitan Toronto Association Residential Siding Contractors Association Low Rise Forming Association of Greater Metropolitan Toronto Mechanical Contractors Association of Ontario Siding and Window Dealers Association National Wood Flooring Association of Canada Ontario Concrete Block Association Structural Board Association Ontario Masonry Contractor’s Association Terrazzo, Marble and Tile Association of Canada Ontario Painting Contractors Association The Concrete Floor Contractors Association of Ontario Construction Performance Guidelines Second Edition, effective December 1, 2003 For more information, call 1-800-668-0124 or visit www.newhome.on.ca 266