1 | P a g e
Wireless Nurse Calling System – Technical Document
Bangalore, India
Wireless Nurse Calling System
Technical Document
[July 2012]
Please feel free to give feedback through: sales@forbixindia.com
2 | P a g e
Wireless Nurse Calling System – Technical Document
NOTICE
FORBIX SEMICON reserves the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service
without notice. Customers should obtain the latest relevant information before placing orders and
should verify that such information is current and complete. All products are sold subject to FORBIX
SEMICON’s terms and conditions of sale supplied at the time of order acknowledgment. Information
contained in this publication regarding device applications is provided only for customer’s convenience
and may be superseded by updates. It is solely customer’s responsibility to ensure that the application
meets the desired specifications. To minimize the risks associated with customer products and
applications, customers should provide adequate design and operating safeguards.
FORBIX SEMICON MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR
IMPLIED, WRITTEN OR ORAL, STATUTORY OR OTHERWISE, RELATED TO THE INFORMATION, INCLUDING
BUT NOT LIMITED TO ITS CONDITION, QUALITY, PERFORMANCE, MERCHANTABILITY OR FITNESS FOR
PURPOSE.
FORBIX SEMICON does not warrant or represent that any license, either express or implied, is granted
under any FORBIX SEMICON copyright, mask work right, or other FORBIX SEMICON’s intellectual
property right relating to any combination, machine, or process in which FORBIX SEMICON products or
services are used. Information published by FORBIX SEMICON regarding third-party products or services
does not constitute a license from FORBIX SEMICON to use such products or services or a warranty or
endorsement thereof.
Reproduction of FORBIX SEMICON information in FORBIX SEMICON data books or data sheets is
permissible only if reproduction is without alteration and is accompanied by all associated warranties,
conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and
deceptive business practice. FORBIX SEMICON is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of FORBIX SEMICON products or services with statements different from or beyond the
parameters stated by FORBIX SEMICON for that product or service voids all express and any implied
warranties for the associated FORBIX SEMICON product or service and is an unfair and deceptive
business practice. FORBIX SEMICON is not responsible or liable for any such statements.
FORBIX SEMICON products are not authorized for use in safety-critical applications (such as life support)
where a failure of the FORBIX SEMICON product would reasonably be expected to cause severe personal
injury or death. Buyers represent that they have all necessary expertise in the safety and regulatory
ramifications of their applications, and acknowledge and agree that they are solely responsible for all
legal, regulatory and safety-related requirements concerning their products and any use of FORBIX
SEMICON products in such safety-critical applications. Further, Buyers must fully indemnify FORBIX
SEMICON and its representatives against any damages arising out of the use of FORBIX SEMICON
products in such safety-critical applications.
FORBIX SEMICON products are neither designed nor intended for use in military/aerospace applications.
Buyers acknowledge and agree that any such use of FORBIX SEMICON products is solely at the Buyer's
risk, and that they are solely responsible for compliance with all legal and regulatory requirements in
connection with such use.
3 | P a g e
Wireless Nurse Calling System – Technical Document
Website Links:
http://www.forbixindia.com
4 | P a g e
Wireless Nurse Calling System – Technical Document
Introduction
o NO Installation, the nurse calling system is ready to use the very next moment it is powered up
o NO Maintenance
o No Wiring
o Simple to use (press button on remote to alert nurse / attendant)
o Cost effective solution (much less cost than wired system, no wiring cost, no installation cost, no
maintenance cost)
o Reliable, Useful and cost effective solution
o Floors with even 2 beds or even up to 100 beds can use the facility
o Running successfully in more than 500 hospitals, dispensaries and offices across the world
(more than 50% only in India)
Other salient features of hospital nurse call system:
o Computerized data logging capability
o Big digital display and Voice Annunciation (visible and audible from 10-30 meters)
o Aesthetic looks. System is in pure white color with a shiny finish
o Remotes can be one room and receiver in another room, with RCC walls in-between
o Long range of communication
o Range can be enhanced to any distance, by intermediate repeaters
o Scalable system. Extra remotes can be added to the existing system
5 | P a g e
Wireless Nurse Calling System – Technical Document
Nurse Station Console Receiver:
• The display window of the receiver console unit 2-
digits, 3-digits, 4-digits
• The calling remote controller number is displayed
on the receiver console unit along with a pre-
recorded voice message annunciation to alert the
nurse / attendant / doctor
• The voice annunciation can be muted by the
nurse (if needed)
• Once the patient has been attended, pressing the
CANCEL button disengages the call from the
console unit
• Multiple calling remote controllers can call the
nurse station. It would systematically rotate the
display for the called numbers
• Operating Voltage: 12VDC @ 1.5A (adapter is
provided along with the set)
• Bright big sized display, digits are visible from
distance for even 50-60 meters
Model: FBXCSL02A
Remote Control Patient Calling Unit:
The handy remote controller has 3 buttons:
Top button: To make a CALL / Call a nurse or attendant
Center: Kept empty (optional customized sound like buzzer
etc.)
Bottom: To CANCEL a call (patient has been attended)
Operating voltage: 12VDC
Battery type: 23A model /12V Battery life: around 1 year Model: FBX521
6 | P a g e
Wireless Nurse Calling System – Technical Document
Repeaters:
The repeater / booster unit is used to increase the
range of communication of the remotes
Any number of repeaters can be installed (preferably
in corridors) to cover multi-storey hospitals
There are 2 varieties of repeaters, viz. normal range
and long range
Operating voltage 12VDC @ 1A (adapter is provided
along with the set)
Model: FBXCSRPT01
Long Range Repeaters:
The long range repeater/booster unit is used to
increase the range of communication of the remotes
Any number of repeaters can be installed (preferably
in corridors) to cover multi-storey hospitals
There are 2 varieties of repeaters, viz. normal range
and long range
Operating voltage 12VDC @ 1A (adapter is provided
along with the set)
Long range repeaters covers double the distance than
normal repeaters. This is around 80-90 meters in open
air line of sight.
7 | P a g e
Wireless Nurse Calling System – Technical Document
Wall mount patient calling point:
This unit consists of 2 buttons
One wired button in the hand of the patient to call
nurse (CALL button)
Second is the CANCEL button on the unit
When CALL button is pressed beep sound is heard,
confirming the press
Operating voltage 12VDC @ 1.5A (adapter is provided
along with the set)
Blue light for power on indication
Red light glows when CALL button is pressed
Door module:
The door module unit is a receiver to a specific set of
remotes (primarily in a room)
It has light indications on 3 sides of the box (the box
needs to be mounted on the wall, on the top of a
door)
Remotes in that particular room when press the CALL
button will glow & blink the door indicator
This is to indicate that one of the patients from the
room is requesting nurse
Operating voltage 12VDC @ 1.5A (adapter is provided
along with the set)
8 | P a g e
Wireless Nurse Calling System – Technical Document
Receiver Console Code Blue:
The nurse call system code blue consists of a (GSM based),
mobile SMS sender. Whenever a CALL button is pressed
from any of the wireless remote calling units a CODE BLUE
sequence is initiated. Under this sequence, the registered
phone number of doctors, nurse and attendant gets an
SMS and missed calls from the console unit. Apart from
this a nurse console station is also located nearby the code
blue console unit that continuously displays the called
location ID.
SMS the doctors receive is: “Ward A: Code BLUE medical
emergency // Please attend as soon as possible“
(The message content can be programmed as per hospital
requirement).
Commands to program the code blue console:
*FBXADD*9876543210# Add the number 09876543210
to receive code blue alert message
*FBXCLR*9876543210# Remove a particular number
09876543210 from the code blue alter messaging system
*FBXCHK# Display the existing registered
mobile numbers
*FBXRST# Clear all registered phone numbers
from the console memory
[In the above example, 9876543210 is the 10-digit mobile
number of the doctor / head nurse / supervisor / manager]
9 | P a g e
Wireless Nurse Calling System – Technical Document
9. Document History
Revision / Date Approved Description / Changes
July-2012 Yes Initial Release
Jan-2014 Yes Added door module and FBX525
May-2015 Yes Added Code Blue Receiver
Use for the intend purpose
The equipment (device, module) may only be used for the application cases specified in the Catalogue
and the user manual and only in connection with devices and components recommended and
approved by FORBIX SEMICON.
FORBIX SEMICON machines should NOT be opened without prior permission from the manufacturer.
Warranty void otherwise.
Exclusion of liability
We have checked the contents of this publication and every effort has been made to ensure that the
descriptions are as accurate as possible. However, deviations from the description cannot be
completely ruled out, so that no liability can be accepted for any errors or omissions in the information
given. The data in this manual is checked regularly and the necessary corrections will be included in
subsequent editions. If you have any suggestions, please let us know via email at:
sales@forbixindia.com
10 | P a g e
Wireless Nurse Calling System – Technical Document

More Related Content

PDF
Luggage Tracker - Travel Tension Free!
PDF
F0463842
PDF
Enterprise Nurse Call Solution
PDF
Nurse Call - How Much Does a Nurse Call System Cost by Room? | MD
PDF
Smart devices in healthcare
PDF
แนวทางการรักษาไข้มาลาเรีย ประเทศไทย 2558
PDF
Toshiba satellite a300_series_a300
PDF
Toshiba User Manual for Satellite A305-s6905 Download
Luggage Tracker - Travel Tension Free!
F0463842
Enterprise Nurse Call Solution
Nurse Call - How Much Does a Nurse Call System Cost by Room? | MD
Smart devices in healthcare
แนวทางการรักษาไข้มาลาเรีย ประเทศไทย 2558
Toshiba satellite a300_series_a300
Toshiba User Manual for Satellite A305-s6905 Download

Similar to Technical doc-wireless-nurse-calling-system (20)

PDF
Touchscreen Clinic Features Added to Provider 790 Clinic System
PDF
Toshiba User Manual Guide Pdf for Satellite C640 - C650
PDF
Satellite c640c650
PDF
Wireless Nurse Call, Panic Alarm, Brochure
PDF
Userguide
PDF
DTMF based Home Automation System
PPS
Systech ppt click version
PPS
Systech ppt click version
PDF
3310 Basic Usuari
PDF
Instructions aeon labs garage door controller gen5
PDF
Edwards Signaling EFSC1004R Installation Manual
PDF
Edwards Signaling EFSC502R Installation Manual
PDF
Edwards Signaling EFSC302RD Installation Manual
PDF
Edwards Signaling E-FSC1004RD Installation Manual
PDF
Edwards Signaling E-FSC502G Installation Manual
PDF
Jeron Showcasing Clinic System at HIMSS17 in Orlando, Booth #4452
PDF
ARA smart hospital Catalog
PDF
Aid Call Touchsafe Pro Brochure - Hospital
PDF
Pcgf420 copy
PDF
Ad830 user manual
Touchscreen Clinic Features Added to Provider 790 Clinic System
Toshiba User Manual Guide Pdf for Satellite C640 - C650
Satellite c640c650
Wireless Nurse Call, Panic Alarm, Brochure
Userguide
DTMF based Home Automation System
Systech ppt click version
Systech ppt click version
3310 Basic Usuari
Instructions aeon labs garage door controller gen5
Edwards Signaling EFSC1004R Installation Manual
Edwards Signaling EFSC502R Installation Manual
Edwards Signaling EFSC302RD Installation Manual
Edwards Signaling E-FSC1004RD Installation Manual
Edwards Signaling E-FSC502G Installation Manual
Jeron Showcasing Clinic System at HIMSS17 in Orlando, Booth #4452
ARA smart hospital Catalog
Aid Call Touchsafe Pro Brochure - Hospital
Pcgf420 copy
Ad830 user manual
Ad

Recently uploaded (20)

PPTX
POSTURE.pptx......,............. .........
PPTX
Public Health. Disasater mgt group 1.pptx
PPT
Pyramid Points Lab Values Power Point(11).ppt
PPTX
Understanding The Self : 1Sexual health
PPTX
Nepal health service act.pptx by Sunil Sharma
PDF
Medical_Biology_and_Genetics_Current_Studies_I.pdf
PPTX
Nancy Caroline Emergency Paramedic Chapter 13
PDF
health promotion and maintenance of elderly
PPTX
Nancy Caroline Emergency Paramedic Chapter 1
PPTX
Nancy Caroline Emergency Paramedic Chapter 14
PPTX
Nancy Caroline Emergency Paramedic Chapter 4
PDF
ENT MedMap you can study for the exam with this.pdf
PPTX
OSTEOMYELITIS and OSTEORADIONECROSIS.pptx
PPTX
Benign prostatic hyperplasia, uro anaesthesia
PDF
Fundamentals Final Review Questions.docx.pdf
PDF
chapter 14.pdf Ch+12+SGOB.docx hilighted important stuff on exa,
PPTX
Nancy Caroline Emergency Paramedic Chapter 7
PDF
Back node with known primary managementt
DOCX
PT10 continues to explose your mind right after reading
DOCX
ch 9 botes for OB aka Pregnant women eww
POSTURE.pptx......,............. .........
Public Health. Disasater mgt group 1.pptx
Pyramid Points Lab Values Power Point(11).ppt
Understanding The Self : 1Sexual health
Nepal health service act.pptx by Sunil Sharma
Medical_Biology_and_Genetics_Current_Studies_I.pdf
Nancy Caroline Emergency Paramedic Chapter 13
health promotion and maintenance of elderly
Nancy Caroline Emergency Paramedic Chapter 1
Nancy Caroline Emergency Paramedic Chapter 14
Nancy Caroline Emergency Paramedic Chapter 4
ENT MedMap you can study for the exam with this.pdf
OSTEOMYELITIS and OSTEORADIONECROSIS.pptx
Benign prostatic hyperplasia, uro anaesthesia
Fundamentals Final Review Questions.docx.pdf
chapter 14.pdf Ch+12+SGOB.docx hilighted important stuff on exa,
Nancy Caroline Emergency Paramedic Chapter 7
Back node with known primary managementt
PT10 continues to explose your mind right after reading
ch 9 botes for OB aka Pregnant women eww
Ad

Technical doc-wireless-nurse-calling-system

  • 1. 1 | P a g e Wireless Nurse Calling System – Technical Document Bangalore, India Wireless Nurse Calling System Technical Document [July 2012] Please feel free to give feedback through: sales@forbixindia.com
  • 2. 2 | P a g e Wireless Nurse Calling System – Technical Document NOTICE FORBIX SEMICON reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to FORBIX SEMICON’s terms and conditions of sale supplied at the time of order acknowledgment. Information contained in this publication regarding device applications is provided only for customer’s convenience and may be superseded by updates. It is solely customer’s responsibility to ensure that the application meets the desired specifications. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. FORBIX SEMICON MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED, WRITTEN OR ORAL, STATUTORY OR OTHERWISE, RELATED TO THE INFORMATION, INCLUDING BUT NOT LIMITED TO ITS CONDITION, QUALITY, PERFORMANCE, MERCHANTABILITY OR FITNESS FOR PURPOSE. FORBIX SEMICON does not warrant or represent that any license, either express or implied, is granted under any FORBIX SEMICON copyright, mask work right, or other FORBIX SEMICON’s intellectual property right relating to any combination, machine, or process in which FORBIX SEMICON products or services are used. Information published by FORBIX SEMICON regarding third-party products or services does not constitute a license from FORBIX SEMICON to use such products or services or a warranty or endorsement thereof. Reproduction of FORBIX SEMICON information in FORBIX SEMICON data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. FORBIX SEMICON is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of FORBIX SEMICON products or services with statements different from or beyond the parameters stated by FORBIX SEMICON for that product or service voids all express and any implied warranties for the associated FORBIX SEMICON product or service and is an unfair and deceptive business practice. FORBIX SEMICON is not responsible or liable for any such statements. FORBIX SEMICON products are not authorized for use in safety-critical applications (such as life support) where a failure of the FORBIX SEMICON product would reasonably be expected to cause severe personal injury or death. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of FORBIX SEMICON products in such safety-critical applications. Further, Buyers must fully indemnify FORBIX SEMICON and its representatives against any damages arising out of the use of FORBIX SEMICON products in such safety-critical applications. FORBIX SEMICON products are neither designed nor intended for use in military/aerospace applications. Buyers acknowledge and agree that any such use of FORBIX SEMICON products is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
  • 3. 3 | P a g e Wireless Nurse Calling System – Technical Document Website Links: http://www.forbixindia.com
  • 4. 4 | P a g e Wireless Nurse Calling System – Technical Document Introduction o NO Installation, the nurse calling system is ready to use the very next moment it is powered up o NO Maintenance o No Wiring o Simple to use (press button on remote to alert nurse / attendant) o Cost effective solution (much less cost than wired system, no wiring cost, no installation cost, no maintenance cost) o Reliable, Useful and cost effective solution o Floors with even 2 beds or even up to 100 beds can use the facility o Running successfully in more than 500 hospitals, dispensaries and offices across the world (more than 50% only in India) Other salient features of hospital nurse call system: o Computerized data logging capability o Big digital display and Voice Annunciation (visible and audible from 10-30 meters) o Aesthetic looks. System is in pure white color with a shiny finish o Remotes can be one room and receiver in another room, with RCC walls in-between o Long range of communication o Range can be enhanced to any distance, by intermediate repeaters o Scalable system. Extra remotes can be added to the existing system
  • 5. 5 | P a g e Wireless Nurse Calling System – Technical Document Nurse Station Console Receiver: • The display window of the receiver console unit 2- digits, 3-digits, 4-digits • The calling remote controller number is displayed on the receiver console unit along with a pre- recorded voice message annunciation to alert the nurse / attendant / doctor • The voice annunciation can be muted by the nurse (if needed) • Once the patient has been attended, pressing the CANCEL button disengages the call from the console unit • Multiple calling remote controllers can call the nurse station. It would systematically rotate the display for the called numbers • Operating Voltage: 12VDC @ 1.5A (adapter is provided along with the set) • Bright big sized display, digits are visible from distance for even 50-60 meters Model: FBXCSL02A Remote Control Patient Calling Unit: The handy remote controller has 3 buttons: Top button: To make a CALL / Call a nurse or attendant Center: Kept empty (optional customized sound like buzzer etc.) Bottom: To CANCEL a call (patient has been attended) Operating voltage: 12VDC Battery type: 23A model /12V Battery life: around 1 year Model: FBX521
  • 6. 6 | P a g e Wireless Nurse Calling System – Technical Document Repeaters: The repeater / booster unit is used to increase the range of communication of the remotes Any number of repeaters can be installed (preferably in corridors) to cover multi-storey hospitals There are 2 varieties of repeaters, viz. normal range and long range Operating voltage 12VDC @ 1A (adapter is provided along with the set) Model: FBXCSRPT01 Long Range Repeaters: The long range repeater/booster unit is used to increase the range of communication of the remotes Any number of repeaters can be installed (preferably in corridors) to cover multi-storey hospitals There are 2 varieties of repeaters, viz. normal range and long range Operating voltage 12VDC @ 1A (adapter is provided along with the set) Long range repeaters covers double the distance than normal repeaters. This is around 80-90 meters in open air line of sight.
  • 7. 7 | P a g e Wireless Nurse Calling System – Technical Document Wall mount patient calling point: This unit consists of 2 buttons One wired button in the hand of the patient to call nurse (CALL button) Second is the CANCEL button on the unit When CALL button is pressed beep sound is heard, confirming the press Operating voltage 12VDC @ 1.5A (adapter is provided along with the set) Blue light for power on indication Red light glows when CALL button is pressed Door module: The door module unit is a receiver to a specific set of remotes (primarily in a room) It has light indications on 3 sides of the box (the box needs to be mounted on the wall, on the top of a door) Remotes in that particular room when press the CALL button will glow & blink the door indicator This is to indicate that one of the patients from the room is requesting nurse Operating voltage 12VDC @ 1.5A (adapter is provided along with the set)
  • 8. 8 | P a g e Wireless Nurse Calling System – Technical Document Receiver Console Code Blue: The nurse call system code blue consists of a (GSM based), mobile SMS sender. Whenever a CALL button is pressed from any of the wireless remote calling units a CODE BLUE sequence is initiated. Under this sequence, the registered phone number of doctors, nurse and attendant gets an SMS and missed calls from the console unit. Apart from this a nurse console station is also located nearby the code blue console unit that continuously displays the called location ID. SMS the doctors receive is: “Ward A: Code BLUE medical emergency // Please attend as soon as possible“ (The message content can be programmed as per hospital requirement). Commands to program the code blue console: *FBXADD*9876543210# Add the number 09876543210 to receive code blue alert message *FBXCLR*9876543210# Remove a particular number 09876543210 from the code blue alter messaging system *FBXCHK# Display the existing registered mobile numbers *FBXRST# Clear all registered phone numbers from the console memory [In the above example, 9876543210 is the 10-digit mobile number of the doctor / head nurse / supervisor / manager]
  • 9. 9 | P a g e Wireless Nurse Calling System – Technical Document 9. Document History Revision / Date Approved Description / Changes July-2012 Yes Initial Release Jan-2014 Yes Added door module and FBX525 May-2015 Yes Added Code Blue Receiver Use for the intend purpose The equipment (device, module) may only be used for the application cases specified in the Catalogue and the user manual and only in connection with devices and components recommended and approved by FORBIX SEMICON. FORBIX SEMICON machines should NOT be opened without prior permission from the manufacturer. Warranty void otherwise. Exclusion of liability We have checked the contents of this publication and every effort has been made to ensure that the descriptions are as accurate as possible. However, deviations from the description cannot be completely ruled out, so that no liability can be accepted for any errors or omissions in the information given. The data in this manual is checked regularly and the necessary corrections will be included in subsequent editions. If you have any suggestions, please let us know via email at: sales@forbixindia.com
  • 10. 10 | P a g e Wireless Nurse Calling System – Technical Document