SlideShare a Scribd company logo
TROUBLESHOOTING IN IMPLANT CROWNS.pptx ppt
TROUBLESHOOTING IN IMPLANT
CROWNS
PRESENTED BY :
M NIKHIL
II YEAR POST GRADUATE
DEPARTMENT OF PROSTHODONTICS
& CROWN AND BRIDGE
INTRODUCTION
 Implant-supported fixed dental prostheses (FDP) represent a well-established
treatment option that has evolved to become a standard of care in dental
practice.
 A successful implant crown restoration is crucial for multiple reasons. It
ensures the functionality of the dentition (chewing and speaking), maintains
oral and systemic health, and provides aesthetic satisfaction to patients.
Unsuccessful restorations can lead to complications like occlusal problems,
peri-implant disease, and patient dissatisfaction.
 Implant supported restorations can be attached to implants with screws or
can be cemented to abutments which are secured to implants with screws.
 Both retention types have been applied for single, multiple and cross-arch
fixed dental prostheses. Long-span prostheses should preferably be screw
retained for easier maintenance.
 However, if the implant is not placed in a prosthetically ideal position– with
the future access hole of the planned crown below the planned incisal edge
position– cement retention is often the only treatment option.
TROUBLESHOOTING IN IMPLANT CROWNS.pptx ppt
 A cement-retained restoration should ideally have 8 mm or more of crown
height space (CHS).
 This dimension permits at least 1 mm for occlusal material on the crown, 5
mm of abut ment height for retention and resistance form (with a subgin gival
margin), a 1-mm subgingival margin, and 2 mm for a junctional epithelial
attachment above the bone
CEMENT RETAINED VS SCREW RETAINED
RETRIEVABILITY
 Implant prostheses have more complications
1. Abutment screw loosening,
2. Porcelain fracture,
3. Crestal bone loss, and
4. Implant failure during the first year of loading.
Axial Load
 A cement-retained implant prosthesis and the implant body may be loaded
axially, thus decreasing crestal bone loads.
 The decrease in crestal bone strain may reduce the incidence of bone loss.
 The ideal location for an occlusal contact is directly over the implant body.
The access hole is rarely loaded, even when filled with composite resin.
Hence, most screw-retained crowns are off-axis loaded.
Hygiene of the Implant Sulcus
 A screw-retained restoration does not fit the abutment or implant body with a
hermetic seal. Therefore, a screw-retained prosthesis does not seal the
abutment-to-crown interface or margin, which may harbor bacteria in the
crevice.
 A cemented crown seals the crown–abutment connection and impairs bacteria
penetration.
 A screw-retained restoration in the anterior region or in the esthetic zone
usually requires the abutment for screw retention to be positioned in the
cingulum or the central fossa region of the crown.
Occlusal Material Fracture
 Occlusal material fracture is more common with implants than natural teeth
because of the lack of periodontal stress relief with implants and a resultant
higher impact force to the occlusal material.
 A decreased incidence of porcelain or acrylic fracture of the prosthesis has
been observed with cement-retained restorations compared with screw-
retained prostheses.
 The screw hole may increase stress concentration to the restoring material
and more often leads to unsupported porcelain.
Access
 Access is more challenging in the posterior regions of the mouth for insertion
of screw-retained restorations, especially in patients with limited jaw
opening.
 The screwdrivers to place and torque the prosthetic screws are usually
greater than 15 mm in height.
Component Fracture
 A long-term complication of screw-retained prostheses is fatigue failure of the
screw components.
 The narrow diameter of the prosthesis screw reduces its long-term strength.
 The bending fracture resistance for a solid object is low. Because the
diameter of the occlusal screw is the smallest of any implant component, the
screw is most at risk for breakage
Cost and Time
 The laboratory costs for a screw-retained restoration are greater than those
for a cemented prosthesis.
 Screw-retained restorations require additional laboratory components such as
impression transfers, analogs, copings, and screws.
 Fewer and shorter prosthetic appointments are required to restore a patient
with a cemented prosthesis than with a screw-retained restoration.
 The need for implant prosthesis removal often is justified by the need to address problems that
have evolved from the screw retained procedure (e.g., prosthetic screw loosening and increased
risk of porcelain fracture).
TROUBLESHOOTING IN IMPLANT CROWNS.pptx ppt
Low-Profile Retention
 The primary advantage of a screw-retained superstructure is the lower profile retention of the
abutment system.
 Cemented prostheses require a vertical component of at least 5 mm to provide retention and
resistance form.
 A crown height reduction of 2 mm may decrease the retention as much as 40% when the implant
abutment is only 4 mm in diameter.
 The screw retained system is more resistant to removal forces than the cement abutment when the
abutment height is less than 5 mm.
 The low-profile abutment may also offer significant advantages for removable
prostheses (RP-4 or RP-5) The lower height of the superstructure permits
easier placement of denture teeth. The greater volume of acrylic also
increases the strength of the acrylic portion of the restoration.
Reduced Moments of Force
 A screw-retained superstructure bar for a RP-5 overdenture (implant and soft
tissue support) may be subjected to less moment forces during prosthesis
movement.
 The moment force to the implant is reduced with a low-profile abutment
when stress breakers on the superstructure separate the removable prosthesis
from the implant support.
Risk of residual cement in the sulcus
 Another advantage of screw-retained crowns is the absence of residual
cement in the gingival crevice, which may cause irritation to the surrounding
tissues and lead to increased plaque retention and inflammation, similar to an
excess cement condition with crowns on natural teeth.
 Subgingival margins increase the incidence of incomplete cement removal on
teeth or implant abutments.
Nonparallel Implants
 When implant bodies are unparallel by more than 30 degrees, an abutment
for cement retention cannot be adequately pre pared for a path of insertion.
 A low-profile screw abutment may engage the implant bodies at significant
angles.
Complications in cement retained prosthesis
 Residual Cement
 The most common complication of a cement-retained implant restoration is
residual cement left in the gingival sulcus of the implant.
 Residual cement in the sulcus after cementation of the prosthesis is a source
of periimplantitis.
 In a report by Wilson, excess dental cement was found in 81% of patients with
clinical or radiologic signs of periimplant disease.
Wilson TG: Positive relationship between excess cement and peri-implant disease: a prospective clinical endoscopic study, J
Periodont 80:1388–1391, 2009.
 An implant–soft tissue interface does not have a connective tissue attachment
zone. A dental probe introduced into the crevice may proceed to the level of
the bone. Hence, there is no barrier to prevent excess cement from extending
deeper into the soft tissue region
Screw retention
 The primary use of screws in implant restorations is to fasten prosthetic
components together.
TROUBLESHOOTING IN IMPLANT CROWNS.pptx ppt
TROUBLESHOOTING IN IMPLANT CROWNS.pptx ppt
Screw Loosening of Abutment and
Prosthetic Screws
 Screw retention of the abutment also presents some potential problems.
 The abutment-to-implant body connection approximates the level of bone
and is several millimeters below the margin of the tissue.
 Reports indicate that as many as 6% to 20% of maxillary prosthetic screws
loosen at least once during the first year of function.
Kallus T, Bessing C: Loose gold screws frequently occur in full arch fixed prostheses supported by
osseointegrated implants after 5 years, Int J Oral Maxillofac Implants 9:169–179, 1994.
Causes of screw loosening and fracture
 Inadequate torque application
 Inaccurate framework abutment interface
 Arch form
 Cantilever extension
 Any discrepancy in occlusion, casting fit, or force may result in vibration
during function and screw loosen ing or breakage where the force is greatest
or the metal dimen sion is weakest.
 This complication protects the implant body from more severe complications.
 However, after they occur in a splinted restoration, the other implant
abutments are at greater risk of overload and complications than the
offending implant because a cantilever and magnification of the load have
been created.
 The access hole through the occlusal material results in an increased risk of
porcelain fracture compared with cement retained restorations.
 In a split-mouth study by Nissan et al. of bilateral edentulous sites, ceramic
fracture occurred in 38% of screw-retained restorations compared to 4% for
cement-retained prostheses.
Nissan J, Narobi D, Gross D, et al: Long term outcome of cemented verses screw retained implant
supported fixed partial restorations, Int J Oral Maxillofac Implants 26:1102–1107, 2011.
Preload
 Preload of an abutment or prosthetic screw is the initial load created by the
application of a torque.
 Preload places the screw in tension and leads to an overclamping force
between the parts of the implant system.
 The aim of tightening a screw using preload stress is to maximize the fatigue
life of the screw yet provide satisfactory resis tance to loosening.
Torque magnitude
 The amount of force applied to tighten a screw joint is related to the success
of the components staying connected.
 Too small a torque leads to low clamping forces, which increase the risk of
loosening.
 The clamping forces on a metal-to-metal screw component are one of the
more important considerations for long-term screw fixation.
 The clamp force is directly proportional to the force used to tighten the
screw.
 The magnitude of the preload is related directly to the clamping force.
Screw head design
 The head of the screw is wider than the outer thread diameter and for an
implant abutment or prosthetic screw may be tapered or flat.
 The tapered head prosthetic screw design reduces the clamping effect and
reduces the tensile force in the threads of the screw. Most of the force within
the tapered screw head is distributed to the head rather than to the fixation
screw component.

TROUBLESHOOTING IN IMPLANT CROWNS.pptx ppt
Screw fracture
 The most common causes of screw fracture are a partially unretained
restoration or fatigue related to the amount of force or the number of cycles.
 Prosthetic screw fracture occurs approximately 4% of the time and abutment
screw fracture 2% of the time. The difference is related to the diameter of
the component.
 There are five options to remove a fractured screw, and the method proceeds
in a particular order.
TROUBLESHOOTING IN IMPLANT CROWNS.pptx ppt
 The second method to remove a fractured screw works only for gold
prosthetic screws.
 An inverted cone drill and slow-speed handpiece is used to drill in the center
of the screw.
 The hand piece is stopped immediately after it penetrates the screw 1 to 2
mm.
 The third method is to make a slot 1 mm deep through the center of the
screw with a high-speed handpiece and a very narrow fissure bur.
 A small screwdriver is then used to unthread the screw
 The fourth method to remove a fractured screw is used when the prosthetic screw
fractures in an abutment for screw reten tion.
 The abutment is removed and replaced with a new abut ment and prosthetic screw of the
same design and size.
 The last option to retrieve an abutment screw is to grind out the fractured abutment with
a high-speed handpiece and fissure bur.
 The heat generated during this process is high enough to cause bone necrosis and implant
failure. The patient is instructed to notify the dentist when the generated heat is
noticeable, which is often less than 5 to 10 seconds after the initial drilling.
Framework fracture
 A cross sectional dimension of atleast 4x6mm is needed.
 Common areas of fracture are
 Solder joints and distal to distal most implant.
 Zarb et al reported an increased incidence of framework breakage if
extensions in mandible exceed 20mm
Prosthetic complications and failures of implant-supported fixed partial dentures: A scoping review
da Silva Bezerra, Aliane et al. Journal of Prosthetic Dentistry, Volume 0, Issue 0,.2023
 Aliane et al conducted a study on prosthetic complications and failures of
implant supported FPDs.
 The search yielded 5695 studies. Fourteen articles were included in this
review for data extraction. Veneering porcelain fracture, screw fracture, and
implant loss were the most common failures reported. Technical
complications mainly involved screw loosening, loss of retention, and wear of
the screw-access restoration.
Review of literature
Goodacre, Brian J et al. “Prosthetic complications with implant prostheses (2001-
2017).” European journal of oral implantology vol. 11 Suppl 1 (2018): S27-S36.
 In a study conducted by brian j et al on prosthetic complications with implant
prosthetics he concluded that Implant overdentures are associated with more
complications than implant fixed complete dentures, implant fixed partial
dentures, and implant single crowns.
 The lowest incidence of complications was reported with implant single
crowns. The most common complication reported with implant fixed
complete dentures was denture tooth fracture.
 Sailer et al. Conducted a systematic review on 59 studies with minimum of 1
year follow up. He concluded that :
 Cemented single crowns: 5-year reconstruction survival was 96.5% .Screw
retained single crowns :89.3%(P=0.091)
 Cemented partial fixed dental prostheses (FDPs):5-year survival rate:96.9%.
Screw retained partial : 98%(P=0.47)
 Cemented full-arch FDPs:5-year survival: 100%; Screw retained :95.8%(P=0.54)
 Estimated 5-year cumulative incidence of technical complications:
 cemented single crowns11.9%; screw retained crowns:24.4%.
 Partial and full-arch FDPs cemented 24.5%, screw retained 22.1%; full-arch
FDPs,cemen ted 62.9%, screw retained 54.1%
 Biological complications such as marginal boneloss >2 mm occurred more
frequently at cemented crowns(5-year incidence:2.8%) than at screw retained
crowns (5-year incidence:0%)
Conclusion
 Successful implant crown restorations require careful planning, accurate
execution, and diligent maintenance.
 Awareness of potential complications and proactive troubleshooting ensures
long-term success and patient satisfaction.
 Implant crown restorations benefit significantly from collaboration among
prosthodontists, periodontists, and dental technicians.
 Each plays a critical role in ensuring success through accurate diagnosis,
precision in fabrication, and management of complications.
References
 Dental Implants Prosthetics, Carl E Misch, 2nd
Edition
 Pietrabissa R, Gionso L, Quaglini V, et al: An in vivo study on compensation
mismatch of screwed vs cement-retained implant supported fixed prostheses,
Clin Oral Implants Res 11:448–457, 2000.
 Nissan J, Narobi D, Gross D, et al: Long term outcome of cemented verses
screw retained implant supported fixed partial restorations, Int J Oral
Maxillofac Implants 26:1102–1107, 2011.
 Kallus T, Bessing C: Loose gold screws frequently occur in full arch fixed
prostheses supported by osseointegrated implants after 5 years, Int J Oral
Maxillofac Implants 9:169–179, 1994.
 Millen C, Bragger U, Wittneben JG. Influence of prosthesis type and retention
mechanism on complications with fixed implant-supported prostheses: a
systematic review apply ing multivariate analyses. Int J Oral Maxillofac
Implants 2015: 30: 110–124.
 Goodacre, Brian J et al. “Prosthetic complications with implant prostheses
(2001-2017).” European journal of oral implantology vol. 11 Suppl 1 (2018):
S27-S36.
 Prosthetic complications and failures of implant-supported fixed partial
dentures: A scoping review da Silva Bezerra, Aliane et al.
Journal of Prosthetic Dentistry, Volume 0, Issue 0,.2023
TROUBLESHOOTING IN IMPLANT CROWNS.pptx ppt

More Related Content

PPTX
Screw retained vs cement retained prosthesis.pptx
PPTX
Screw vs cement retained implant prosthesis
PDF
cement-retained versus screw-retained implant restorations
PPTX
Management of abutment screw loosening: a review and a case report -jc-8-subh...
DOC
Cement Retained Versus Screw Retained Implant Restorations Achieving Optimal
PDF
17 implant abutment 1
PPTX
Screw retained vs cement retained prosthesis.pptx
PPTX
Prosthetic components in dental implantology Dr.Catherine Maundu
Screw retained vs cement retained prosthesis.pptx
Screw vs cement retained implant prosthesis
cement-retained versus screw-retained implant restorations
Management of abutment screw loosening: a review and a case report -jc-8-subh...
Cement Retained Versus Screw Retained Implant Restorations Achieving Optimal
17 implant abutment 1
Screw retained vs cement retained prosthesis.pptx
Prosthetic components in dental implantology Dr.Catherine Maundu

Similar to TROUBLESHOOTING IN IMPLANT CROWNS.pptx ppt (20)

PDF
B8842
PPTX
ImplantMaintenance.pptx
PPT
Cement vs screw retained implant prosthesis.ppt
PPTX
Second Stage Dental Implants - Copy.pptx
PDF
Dental implants cement retention vs screw retention
PPTX
Journal Club Presentationn 3 Cement.pptx
PPTX
Actual journal club in dentistry be like
PDF
Prosthodontics Procedures and Complications - Posterior Quadrants
PPTX
Screw versus Cement for Implant Prosthesis Installation. Part 2: The Game Cha...
PPTX
Technical Complications in implant dentistry46.pptx
PPTX
Presentation1
PPTX
Tooth implant connection, fix partial dentur,
PPTX
dentalimplant-160204161826.pptx
PPTX
Dental implant
PPTX
Screw Vs Cement for Dental Implant Prosthesis Installation Part 1: The Logic ...
PPTX
Dental Implants Basic Overview Presentation
PPTX
Implant intruduction misch contemporary implant dentistry Dr fariborz vafaee
PDF
B8842
ImplantMaintenance.pptx
Cement vs screw retained implant prosthesis.ppt
Second Stage Dental Implants - Copy.pptx
Dental implants cement retention vs screw retention
Journal Club Presentationn 3 Cement.pptx
Actual journal club in dentistry be like
Prosthodontics Procedures and Complications - Posterior Quadrants
Screw versus Cement for Implant Prosthesis Installation. Part 2: The Game Cha...
Technical Complications in implant dentistry46.pptx
Presentation1
Tooth implant connection, fix partial dentur,
dentalimplant-160204161826.pptx
Dental implant
Screw Vs Cement for Dental Implant Prosthesis Installation Part 1: The Logic ...
Dental Implants Basic Overview Presentation
Implant intruduction misch contemporary implant dentistry Dr fariborz vafaee
Ad

More from NikhilMandadi (16)

PPTX
Shareen implant basic.pptx Shareen implant basic.pptx
PPTX
Certificate of Appreciation[1].pptx2222222222
PPTX
diagnosisandtreatmentplanningincompletedenturepatients-191008155942 (1).pptx
PPTX
slidesaver.app_ieejvu.pptx 11111111111111111111111111
PPTX
articulators used in prosthodontics AND and
PPTX
An Alternative Technique For Transferring Ala‑tragus[1].pptx
PPTX
TELESCOPIC PROSTHESIS CPD CH.nnnnnnnpptx
PPTX
14) A_PREFABRICATED_MODULAR_SUBSTRUCTURE_FOR_A_4-IMPLANTSUPPORTED_FIXED_COMPL...
PPTX
11) implant supported overdenture.pptx aa
PPTX
MULTI -CUP DENTURES ARE SO GOOD AND SO COOL
PPTX
JC BONE AUMENTATION IS SO GOOD AND SO COOL
PPTX
4) Socket shield technique prosthodontics
PPTX
An insight into intraoral scanner technology
PDF
cons endo spotters for final bds students
PDF
knr final yr ques papers for my school in a week
PPTX
Periodontics spotters for final bds practical examination
Shareen implant basic.pptx Shareen implant basic.pptx
Certificate of Appreciation[1].pptx2222222222
diagnosisandtreatmentplanningincompletedenturepatients-191008155942 (1).pptx
slidesaver.app_ieejvu.pptx 11111111111111111111111111
articulators used in prosthodontics AND and
An Alternative Technique For Transferring Ala‑tragus[1].pptx
TELESCOPIC PROSTHESIS CPD CH.nnnnnnnpptx
14) A_PREFABRICATED_MODULAR_SUBSTRUCTURE_FOR_A_4-IMPLANTSUPPORTED_FIXED_COMPL...
11) implant supported overdenture.pptx aa
MULTI -CUP DENTURES ARE SO GOOD AND SO COOL
JC BONE AUMENTATION IS SO GOOD AND SO COOL
4) Socket shield technique prosthodontics
An insight into intraoral scanner technology
cons endo spotters for final bds students
knr final yr ques papers for my school in a week
Periodontics spotters for final bds practical examination
Ad

Recently uploaded (20)

PDF
David L Page_DCI Research Study Journey_how Methodology can inform one's prac...
PPTX
Virtual and Augmented Reality in Current Scenario
PDF
OBE - B.A.(HON'S) IN INTERIOR ARCHITECTURE -Ar.MOHIUDDIN.pdf
PDF
Trump Administration's workforce development strategy
PDF
MBA _Common_ 2nd year Syllabus _2021-22_.pdf
PDF
Empowerment Technology for Senior High School Guide
PPTX
A powerpoint presentation on the Revised K-10 Science Shaping Paper
PDF
FORM 1 BIOLOGY MIND MAPS and their schemes
PPTX
20th Century Theater, Methods, History.pptx
PPTX
Computer Architecture Input Output Memory.pptx
PPTX
Introduction to pro and eukaryotes and differences.pptx
PPTX
Chinmaya Tiranga Azadi Quiz (Class 7-8 )
PDF
BP 704 T. NOVEL DRUG DELIVERY SYSTEMS (UNIT 1)
PPTX
B.Sc. DS Unit 2 Software Engineering.pptx
PPTX
Onco Emergencies - Spinal cord compression Superior vena cava syndrome Febr...
PDF
Paper A Mock Exam 9_ Attempt review.pdf.
PDF
What if we spent less time fighting change, and more time building what’s rig...
PDF
advance database management system book.pdf
PDF
HVAC Specification 2024 according to central public works department
PDF
IGGE1 Understanding the Self1234567891011
David L Page_DCI Research Study Journey_how Methodology can inform one's prac...
Virtual and Augmented Reality in Current Scenario
OBE - B.A.(HON'S) IN INTERIOR ARCHITECTURE -Ar.MOHIUDDIN.pdf
Trump Administration's workforce development strategy
MBA _Common_ 2nd year Syllabus _2021-22_.pdf
Empowerment Technology for Senior High School Guide
A powerpoint presentation on the Revised K-10 Science Shaping Paper
FORM 1 BIOLOGY MIND MAPS and their schemes
20th Century Theater, Methods, History.pptx
Computer Architecture Input Output Memory.pptx
Introduction to pro and eukaryotes and differences.pptx
Chinmaya Tiranga Azadi Quiz (Class 7-8 )
BP 704 T. NOVEL DRUG DELIVERY SYSTEMS (UNIT 1)
B.Sc. DS Unit 2 Software Engineering.pptx
Onco Emergencies - Spinal cord compression Superior vena cava syndrome Febr...
Paper A Mock Exam 9_ Attempt review.pdf.
What if we spent less time fighting change, and more time building what’s rig...
advance database management system book.pdf
HVAC Specification 2024 according to central public works department
IGGE1 Understanding the Self1234567891011

TROUBLESHOOTING IN IMPLANT CROWNS.pptx ppt

  • 2. TROUBLESHOOTING IN IMPLANT CROWNS PRESENTED BY : M NIKHIL II YEAR POST GRADUATE DEPARTMENT OF PROSTHODONTICS & CROWN AND BRIDGE
  • 3. INTRODUCTION  Implant-supported fixed dental prostheses (FDP) represent a well-established treatment option that has evolved to become a standard of care in dental practice.  A successful implant crown restoration is crucial for multiple reasons. It ensures the functionality of the dentition (chewing and speaking), maintains oral and systemic health, and provides aesthetic satisfaction to patients. Unsuccessful restorations can lead to complications like occlusal problems, peri-implant disease, and patient dissatisfaction.
  • 4.  Implant supported restorations can be attached to implants with screws or can be cemented to abutments which are secured to implants with screws.  Both retention types have been applied for single, multiple and cross-arch fixed dental prostheses. Long-span prostheses should preferably be screw retained for easier maintenance.  However, if the implant is not placed in a prosthetically ideal position– with the future access hole of the planned crown below the planned incisal edge position– cement retention is often the only treatment option.
  • 6.  A cement-retained restoration should ideally have 8 mm or more of crown height space (CHS).  This dimension permits at least 1 mm for occlusal material on the crown, 5 mm of abut ment height for retention and resistance form (with a subgin gival margin), a 1-mm subgingival margin, and 2 mm for a junctional epithelial attachment above the bone
  • 7. CEMENT RETAINED VS SCREW RETAINED
  • 8. RETRIEVABILITY  Implant prostheses have more complications 1. Abutment screw loosening, 2. Porcelain fracture, 3. Crestal bone loss, and 4. Implant failure during the first year of loading.
  • 9. Axial Load  A cement-retained implant prosthesis and the implant body may be loaded axially, thus decreasing crestal bone loads.  The decrease in crestal bone strain may reduce the incidence of bone loss.  The ideal location for an occlusal contact is directly over the implant body. The access hole is rarely loaded, even when filled with composite resin. Hence, most screw-retained crowns are off-axis loaded.
  • 10. Hygiene of the Implant Sulcus  A screw-retained restoration does not fit the abutment or implant body with a hermetic seal. Therefore, a screw-retained prosthesis does not seal the abutment-to-crown interface or margin, which may harbor bacteria in the crevice.  A cemented crown seals the crown–abutment connection and impairs bacteria penetration.  A screw-retained restoration in the anterior region or in the esthetic zone usually requires the abutment for screw retention to be positioned in the cingulum or the central fossa region of the crown.
  • 11. Occlusal Material Fracture  Occlusal material fracture is more common with implants than natural teeth because of the lack of periodontal stress relief with implants and a resultant higher impact force to the occlusal material.  A decreased incidence of porcelain or acrylic fracture of the prosthesis has been observed with cement-retained restorations compared with screw- retained prostheses.  The screw hole may increase stress concentration to the restoring material and more often leads to unsupported porcelain.
  • 12. Access  Access is more challenging in the posterior regions of the mouth for insertion of screw-retained restorations, especially in patients with limited jaw opening.  The screwdrivers to place and torque the prosthetic screws are usually greater than 15 mm in height.
  • 13. Component Fracture  A long-term complication of screw-retained prostheses is fatigue failure of the screw components.  The narrow diameter of the prosthesis screw reduces its long-term strength.  The bending fracture resistance for a solid object is low. Because the diameter of the occlusal screw is the smallest of any implant component, the screw is most at risk for breakage
  • 14. Cost and Time  The laboratory costs for a screw-retained restoration are greater than those for a cemented prosthesis.  Screw-retained restorations require additional laboratory components such as impression transfers, analogs, copings, and screws.  Fewer and shorter prosthetic appointments are required to restore a patient with a cemented prosthesis than with a screw-retained restoration.
  • 15.  The need for implant prosthesis removal often is justified by the need to address problems that have evolved from the screw retained procedure (e.g., prosthetic screw loosening and increased risk of porcelain fracture).
  • 17. Low-Profile Retention  The primary advantage of a screw-retained superstructure is the lower profile retention of the abutment system.  Cemented prostheses require a vertical component of at least 5 mm to provide retention and resistance form.  A crown height reduction of 2 mm may decrease the retention as much as 40% when the implant abutment is only 4 mm in diameter.  The screw retained system is more resistant to removal forces than the cement abutment when the abutment height is less than 5 mm.
  • 18.  The low-profile abutment may also offer significant advantages for removable prostheses (RP-4 or RP-5) The lower height of the superstructure permits easier placement of denture teeth. The greater volume of acrylic also increases the strength of the acrylic portion of the restoration.
  • 19. Reduced Moments of Force  A screw-retained superstructure bar for a RP-5 overdenture (implant and soft tissue support) may be subjected to less moment forces during prosthesis movement.  The moment force to the implant is reduced with a low-profile abutment when stress breakers on the superstructure separate the removable prosthesis from the implant support.
  • 20. Risk of residual cement in the sulcus  Another advantage of screw-retained crowns is the absence of residual cement in the gingival crevice, which may cause irritation to the surrounding tissues and lead to increased plaque retention and inflammation, similar to an excess cement condition with crowns on natural teeth.  Subgingival margins increase the incidence of incomplete cement removal on teeth or implant abutments.
  • 21. Nonparallel Implants  When implant bodies are unparallel by more than 30 degrees, an abutment for cement retention cannot be adequately pre pared for a path of insertion.  A low-profile screw abutment may engage the implant bodies at significant angles.
  • 22. Complications in cement retained prosthesis  Residual Cement  The most common complication of a cement-retained implant restoration is residual cement left in the gingival sulcus of the implant.  Residual cement in the sulcus after cementation of the prosthesis is a source of periimplantitis.  In a report by Wilson, excess dental cement was found in 81% of patients with clinical or radiologic signs of periimplant disease. Wilson TG: Positive relationship between excess cement and peri-implant disease: a prospective clinical endoscopic study, J Periodont 80:1388–1391, 2009.
  • 23.  An implant–soft tissue interface does not have a connective tissue attachment zone. A dental probe introduced into the crevice may proceed to the level of the bone. Hence, there is no barrier to prevent excess cement from extending deeper into the soft tissue region
  • 24. Screw retention  The primary use of screws in implant restorations is to fasten prosthetic components together.
  • 27. Screw Loosening of Abutment and Prosthetic Screws  Screw retention of the abutment also presents some potential problems.  The abutment-to-implant body connection approximates the level of bone and is several millimeters below the margin of the tissue.  Reports indicate that as many as 6% to 20% of maxillary prosthetic screws loosen at least once during the first year of function. Kallus T, Bessing C: Loose gold screws frequently occur in full arch fixed prostheses supported by osseointegrated implants after 5 years, Int J Oral Maxillofac Implants 9:169–179, 1994.
  • 28. Causes of screw loosening and fracture  Inadequate torque application  Inaccurate framework abutment interface  Arch form  Cantilever extension
  • 29.  Any discrepancy in occlusion, casting fit, or force may result in vibration during function and screw loosen ing or breakage where the force is greatest or the metal dimen sion is weakest.  This complication protects the implant body from more severe complications.  However, after they occur in a splinted restoration, the other implant abutments are at greater risk of overload and complications than the offending implant because a cantilever and magnification of the load have been created.
  • 30.  The access hole through the occlusal material results in an increased risk of porcelain fracture compared with cement retained restorations.  In a split-mouth study by Nissan et al. of bilateral edentulous sites, ceramic fracture occurred in 38% of screw-retained restorations compared to 4% for cement-retained prostheses. Nissan J, Narobi D, Gross D, et al: Long term outcome of cemented verses screw retained implant supported fixed partial restorations, Int J Oral Maxillofac Implants 26:1102–1107, 2011.
  • 31. Preload  Preload of an abutment or prosthetic screw is the initial load created by the application of a torque.  Preload places the screw in tension and leads to an overclamping force between the parts of the implant system.  The aim of tightening a screw using preload stress is to maximize the fatigue life of the screw yet provide satisfactory resis tance to loosening.
  • 32. Torque magnitude  The amount of force applied to tighten a screw joint is related to the success of the components staying connected.  Too small a torque leads to low clamping forces, which increase the risk of loosening.  The clamping forces on a metal-to-metal screw component are one of the more important considerations for long-term screw fixation.  The clamp force is directly proportional to the force used to tighten the screw.  The magnitude of the preload is related directly to the clamping force.
  • 33. Screw head design  The head of the screw is wider than the outer thread diameter and for an implant abutment or prosthetic screw may be tapered or flat.  The tapered head prosthetic screw design reduces the clamping effect and reduces the tensile force in the threads of the screw. Most of the force within the tapered screw head is distributed to the head rather than to the fixation screw component. 
  • 35. Screw fracture  The most common causes of screw fracture are a partially unretained restoration or fatigue related to the amount of force or the number of cycles.  Prosthetic screw fracture occurs approximately 4% of the time and abutment screw fracture 2% of the time. The difference is related to the diameter of the component.  There are five options to remove a fractured screw, and the method proceeds in a particular order.
  • 37.  The second method to remove a fractured screw works only for gold prosthetic screws.  An inverted cone drill and slow-speed handpiece is used to drill in the center of the screw.  The hand piece is stopped immediately after it penetrates the screw 1 to 2 mm.  The third method is to make a slot 1 mm deep through the center of the screw with a high-speed handpiece and a very narrow fissure bur.  A small screwdriver is then used to unthread the screw
  • 38.  The fourth method to remove a fractured screw is used when the prosthetic screw fractures in an abutment for screw reten tion.  The abutment is removed and replaced with a new abut ment and prosthetic screw of the same design and size.  The last option to retrieve an abutment screw is to grind out the fractured abutment with a high-speed handpiece and fissure bur.  The heat generated during this process is high enough to cause bone necrosis and implant failure. The patient is instructed to notify the dentist when the generated heat is noticeable, which is often less than 5 to 10 seconds after the initial drilling.
  • 39. Framework fracture  A cross sectional dimension of atleast 4x6mm is needed.  Common areas of fracture are  Solder joints and distal to distal most implant.  Zarb et al reported an increased incidence of framework breakage if extensions in mandible exceed 20mm
  • 40. Prosthetic complications and failures of implant-supported fixed partial dentures: A scoping review da Silva Bezerra, Aliane et al. Journal of Prosthetic Dentistry, Volume 0, Issue 0,.2023  Aliane et al conducted a study on prosthetic complications and failures of implant supported FPDs.  The search yielded 5695 studies. Fourteen articles were included in this review for data extraction. Veneering porcelain fracture, screw fracture, and implant loss were the most common failures reported. Technical complications mainly involved screw loosening, loss of retention, and wear of the screw-access restoration. Review of literature
  • 41. Goodacre, Brian J et al. “Prosthetic complications with implant prostheses (2001- 2017).” European journal of oral implantology vol. 11 Suppl 1 (2018): S27-S36.  In a study conducted by brian j et al on prosthetic complications with implant prosthetics he concluded that Implant overdentures are associated with more complications than implant fixed complete dentures, implant fixed partial dentures, and implant single crowns.  The lowest incidence of complications was reported with implant single crowns. The most common complication reported with implant fixed complete dentures was denture tooth fracture.
  • 42.  Sailer et al. Conducted a systematic review on 59 studies with minimum of 1 year follow up. He concluded that :  Cemented single crowns: 5-year reconstruction survival was 96.5% .Screw retained single crowns :89.3%(P=0.091)  Cemented partial fixed dental prostheses (FDPs):5-year survival rate:96.9%. Screw retained partial : 98%(P=0.47)  Cemented full-arch FDPs:5-year survival: 100%; Screw retained :95.8%(P=0.54)  Estimated 5-year cumulative incidence of technical complications:  cemented single crowns11.9%; screw retained crowns:24.4%.  Partial and full-arch FDPs cemented 24.5%, screw retained 22.1%; full-arch FDPs,cemen ted 62.9%, screw retained 54.1%  Biological complications such as marginal boneloss >2 mm occurred more frequently at cemented crowns(5-year incidence:2.8%) than at screw retained crowns (5-year incidence:0%)
  • 43. Conclusion  Successful implant crown restorations require careful planning, accurate execution, and diligent maintenance.  Awareness of potential complications and proactive troubleshooting ensures long-term success and patient satisfaction.  Implant crown restorations benefit significantly from collaboration among prosthodontists, periodontists, and dental technicians.  Each plays a critical role in ensuring success through accurate diagnosis, precision in fabrication, and management of complications.
  • 44. References  Dental Implants Prosthetics, Carl E Misch, 2nd Edition  Pietrabissa R, Gionso L, Quaglini V, et al: An in vivo study on compensation mismatch of screwed vs cement-retained implant supported fixed prostheses, Clin Oral Implants Res 11:448–457, 2000.  Nissan J, Narobi D, Gross D, et al: Long term outcome of cemented verses screw retained implant supported fixed partial restorations, Int J Oral Maxillofac Implants 26:1102–1107, 2011.  Kallus T, Bessing C: Loose gold screws frequently occur in full arch fixed prostheses supported by osseointegrated implants after 5 years, Int J Oral Maxillofac Implants 9:169–179, 1994.
  • 45.  Millen C, Bragger U, Wittneben JG. Influence of prosthesis type and retention mechanism on complications with fixed implant-supported prostheses: a systematic review apply ing multivariate analyses. Int J Oral Maxillofac Implants 2015: 30: 110–124.  Goodacre, Brian J et al. “Prosthetic complications with implant prostheses (2001-2017).” European journal of oral implantology vol. 11 Suppl 1 (2018): S27-S36.  Prosthetic complications and failures of implant-supported fixed partial dentures: A scoping review da Silva Bezerra, Aliane et al. Journal of Prosthetic Dentistry, Volume 0, Issue 0,.2023

Editor's Notes

  • #4: Therefore, proper treatment planning and prosthetically driven implant placement should be mandatory for implant therapy.
  • #5: Both retention types have their advantages and limitations. It is therefore the clinician’s responsibility to select the most appropriate method of retention for the individual case.
  • #8: As such, if the prostheses were able to be removed, it would be advantageous.
  • #9: To direct loads along the long axis of the implant body with a screw-retained crown, occlusal adjustments are made on the occlusal composite obturation placed over the top of the screw.
  • #10: As a consequence, the facial aspect of the implant crown is cantilevered from the implant with a ridge lap of porcelain, which complicates hygiene procedures at the facial cervical region
  • #12: The manipulation of small screws and screwdrivers is far more time consuming and challenging than the abutment preparation and cementation of a cemented restoration.
  • #15: Clinical experience, case series studies, and implant registries indicate higher complication rates with screw-retained fixed profession has evolved and understands the benefit of cement retained restorations, the trend toward the use of cement retained prostheses has grown.
  • #18: An abutment with reduced height may be required when the implant is positioned too lingual or palatal. A 5-mm or greater height of the abutment may interfere with a tongue position or occlusion.
  • #19: These elements decrease the effect of lateral loads on the implant body.
  • #20: When possible, the crown margin of a cement-retained prosthesis should be above the tissue so that cement excess can be readily removed.
  • #21: For example, a pterygoid or zygomatic implant may be placed at 45 degrees from anterior implants, yet these implants may be splinted together with a screw-retained restoration.
  • #22: The occurrence of this complication is more often found with implants than natural teeth.
  • #24: In almost all implant systems, a screw is used to fixate the abutment component (i.e., abutment for cement retention, abutment for screw retention and abutment for attachment) to the implant body
  • #27: It may not be completely hermetically sealed and may contribute to bacterial infection, especially when the abutment screw becomes loose.
  • #28: Recommmended torque for prosthetic gold screw is 10ncm and 20 for abutmnt screw Ideal framework abutment connection will have circumferential contact with out opening interface. When arch form is maintained , a tripod effect lessens bonding moments transmitted to the screw joints Cantilever extension- 15mm or less in mandible 10 or less in maxilla Over extension may lead to screw loosening or fracture,prosthesis loosening,implant loss due to over load
  • #29: Many conditions that cause prosthetic screw loosening also affect a cement-retained restoration, but the cement seal is often not the weakest link.
  • #31: and causes elongation of the screw
  • #33: But taper design should not be used in prosthetic screw as head may get distorted. So flat screws should be used.
  • #36: The first method most always is successful and takes only a few minutes. A very small, round bur is used in a slow-speed handpiece, preferably below 50 rpm. The round bur is placed at the seam of the fractured screw and abutment (implant). As the bur spins clockwise, the friction on the screw makes it turn counterclockwise, and the screw unthreads
  • #37: The bur sticks in the gold screw. The bur is unattached from the handpiece, and the bur and fractured screw are unthreaded.
  • #38: This process has the most risk. The process is performed with copious amounts of water and no anesthesia. . The process continues in these short intervals until the abutment is removed.