PRO SERIES
                      USER MANUAL

                           FOR THE

                         PS 19 M
           SINGLE CHANNEL BELTPACK




      CONTENTS

                1.0   GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . .                   3
                2.0   UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .       3
                3.0   INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .        3
                4.0   FRONT PANEL CONTROLS . . . . . . . . . . . . . . . . . . . .                      4
                5.0   REAR PANEL CONNECTORS . . . . . . . . . . . . . . . . . . .                       4
                6.0   BOTTOM CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . .                 5
                7.0   CABLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   6
                8.0   PARTY LINE, TECHNICAL CONCEPT . . . . . . . . . . . .                             7
                9.0   GUARANTEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .         7
               10.0   TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . .                      7




User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
2   User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
1.0     GENERAL DESCRIPTION


       The PS 19M is a portable single channel user station.          The unique ASL CALL system provides both a flashing
       It is housed in a strong aluminium case and is                 red LED and a very distinctive and characteristic
       provided with a steel beltclip.                                sound signal. Smooth operation is guaranteed with the
                                                                      CALL button. A momentary push makes the extra
       On the front panel are a Volume (listen level) control, a      bright red LED flash, whilst holding the button for two
       Talk and a Call button with LED indicators.                    seconds will activate the CALL sound signal. The
                                                                      volume of the sound signal (buzzer) can be adjusted at
       Special attention has been paid to the intelligibility of      the front panel.
       speech. By applying low noise/high speed opamps, a
       speech presence filter and a specially developed high          Fully electronic switching increases reliability and
       power bridged headphone amplifier, communication is            allows for :
       very comfortable even in environments with high                - 'soft' microphone ON switching, latched or
       background noise level.                                            momentary
                                                                      - remote Mic Mute facility.




   2.0     UNPACKING


       The shipping carton contains the parts listed below            After unpacking the unit please inspect for any
           * The PS 19M                                               physical damage to the unit, and retain the shipping
           * User manual                                              carton and relevant packing materials for use should
       If any are missing, contact your dealer.                       the unit need returning.

       ASL has taken great care to ensure this product                If any damage has occured, please notify your dealer
       reaches you in flawless condition.                             immediately so that a written claim can be initiated.
                                                                      Please also refer to the guarantee section of this
                                                                      manual.




   3.0     INSTALLATION


       This PS 19M will form part of an existing or new               To connect the PS 19M onto the intercom system, use
       intercom system, and connection to it is straightfor-          professional flexible microphone cable with 2 wires
       ward. There are no separate power connections, or              and 1 shield only. Connect the system intercom cable
       batteries to install, as the necessary DC voltages are         into the LINE connector socket on the rear panel.
       derived from the intercom master station or power              Finally connect the listening headset plug into the
       supply, via the intercom connection cable.                     HEADSET connector, also on the rear panel.

                                                                      The PS 19M is fully protected against mis-wiring
                                                                      (reverse power) or short-circuit in the interconnecting
                                                                      cables.




User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.                                                          3
4.0   FRONT PANEL CONTROLS


  1   VOLUME control knob
      This knob adjusts the listen level for the headset.

  2   TALK button
      This push button activates the headset
      microphone, the bright green LED(4) indicates if
      the microphone is switched on.
      Latched switching:
      When a TALK button is pressed quickly, the
      microphone will be switched on, and is
      electronically latched. When pressed again, the
      microphone will be switched off.
      Momentary switching:
      When a TALK button is pressed and held, the
      microphone will be active until the button is
      released.

      When the microphone is latched on, it can be
      muted by a Mic Mute from a PRO Series master
      station or power supply.

  3   CALL button
      This push button activates the call system.
      A momentary push will send a call signal to all
      stations connected to the intercom channel and the
      call LEDS will start flashing.
      Press and hold the button for 2 seconds will
      activate the call buzzer, if not muted.
      After the CALL button is released the LEDS will
      continue to flash for further 2 seconds.


5.0   REAR PANEL CONNECTORS


  4   LINE connectors
      These XLR-3 connectors are for connecting the PS
      19M to the intercom system.

      Pin assignments :
         1. 0 V / ground shield
         2. +30 V power wire
         3. audio wire

      The female connector is for input.
      The male connector is for extending the intercom
      line to other user stations.

  5   HEADSET connector
      An XLR-4 type connector for the connection of the
      local headset. This must have a can impedance of
      200 ohms (or greater), or each 400 ohms minimum
      when in parallel. The mic may be of the dynamic or
      electret type.

      Pin assignments :
         1. Shield mic. (GND)
         2. mic. +
         3. phones +
         4. phones -



  4                                                         User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
6.0     BOTTOM CONTROLS


       4 MIC GAIN
         The mic gain can be adjusted internally by a
         trimmer.                                                     6   BUZZER VOLUME trimmer
                                                                          This trimmer adjusts the volume of the internal
           -   Open the PS 19M by removing the four screws                buzzer, which is located behind the front panel.
               on the under side.                                         The buzzer is activated if you press the CALL
           -   The trimmer is located on the lower PCB board.             button of the PS 19 (3) or a CALL button of any
                                                                          other station (on the channel to which the PS 19M
               To increase mic gain turn clockwise.                       is connected), longer than 2 seconds and the
               To decrease mic gain turn counterclockwise.                buzzers are not muted (on the master station or
                                                                          power supply).
       5   SIDETONE trimmer
           This trimmer adjusts the level of your own voice as
           you hear it in your headset.

           Adjustment procedure :
           - set trimmer in start position : fully clockwise.
           - switch off the microphone of all connected
              (speaker!) stations.
           - switch on the microphone of the PS 19.
           - turn up volume.
           - speak into the headset microphone.
           - adjust the listen level by turning the sidetone
              trimmer.

           The operating area is between fully clockwise and
           minimum level. Adjusting the sidetone does not
           affect the level of your voice as it is heard by other
           stations.




User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.                                                       5
7.0   CABLING


      For the PRO Series Intercom system the
      interconnecting cables are of the shielded two-
      conductor microphone cable type and the intercom
      line connectors are of the XLR-3 type. Audio and Call
      signals are on XLR pin 3, DC power is on XLR pin 2.
      XLR pin 1 is connected to the shield of the cable which
      functions as the common return for audio and power.

      Since the audio signal is transferred in an unbalanced
      þ way, certain rules have to be obeyed when installing
      the cables of an intercom network. This is to avoid
      earth loops and to minimize power loss and the
      possible effect of electromagnetic fields.

      These rules are:

      þ Use high quality (multipair) cable.                            þ Keep cables parallel as much as possible.
        For interconnecting user stations, power supplies                When two (multi channel) units in a network are
        and accessories in an ASL Intercom network, use                  connected by more than one cable, make sure that
        high quality shielded two-conductor (minimum 2x                  these cables are parallel to each other over the
        0.30 mm2) microphone cable only.                                 whole distance between those units. When using
        In case of a multi channel intercom network, use                 multipair cable, parallelism is ensured in the best
        high quality microphone 'multipair' cable only, each             possible way.
        pair consisting of two conductors (minimum 2x
        0.15 mm2) with separate shield. Multipair cable                þ Avoid closed loops.
        should also have an overall shield.                              Always avoid that cables are making a loop. So-
                                                                         called 'ring intercom' should not physically be
      þ Use flexible cables.                                             cabled as a ring. All cable routes should have a
        Use flexible single and multipair microphone cable               'star' configuration, with the central earthing point
        instead of cable with solid cores, especially when               (usually close to the power supply position) as the
        the cable is subjected to bending during operation               center of the star.
        or installation.
                                                                       þ Keep cables away from electromagnetic sources.
      þ Separate cable screen to XLR pin 1.                              Keep intercom cables away from high energy
        The screen of each separate microphone cable                     cables, e.g. 110/220/380V mains power or dimmer
        and/or the screen of each single pair in a multipair             controlled feeds for spotlights.
        cable, should be connected to pin 1 of each XLR-3                Intercom cables should cross high energy cables
        connector. Do not connect this cable screen to the               at an angle of 90þ only.
        metal housing of the connector or to metal wall                  Intercom cables should never be in the same
        boxes (outlets).                                                 trunking as energy cables.
        See page 10: Earthing Concept.
                                                                       þ Place power supply in a central position.
      þ Cable trunks, connection boxes and overall                       In order to avoid unacceptable power losses, place
        multipair cable screen to clean earth.                           the power supply as close as possible to where
        Metal cable trunks, metal connection boxes and                   most power consumption occurs or, in other
        overall multipair cable screen should be inter-                  words, most user stations are placed.
        connected and, at one point (the 'central earthing
        point') in the intercom network only, be connected             þ Connect ASL power supply to a 'clean' mains
        to a clean earth or a safety earth.                              outlet.
        See page 10: Earthing Concept.                                   The ASL power supply may be connected to the
                                                                         mains power outlet to which other audio equipment
      þ Keep metal connection boxes and cable housings                   is connected. Avoid using mains outlets which also
        isolated from other metal parts.                                 power dimmer controlled lighting systems.
        Metal housings for intercom cables and connectors
        should be mounted in such a way that they are                     In case of more complex installations, don't
        isolated from other metal cable and connector                     hesitate to contact us. Please send us a block
        housings and from any other metal construction                    diagram of the planned network with a list of all
        parts.                                                            user stations and their positions, and we are happy
                                                                          to advise you on cabling lay out.
      þ See Party Line, Technical Concept




6                                                              User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
8.0     PARTY LINE, TECHNICAL CONCEPT                              10.0 TECHNICAL SPECIFICATIONS PS 19M


       ASL's PRO Series offers a complete two way ('full              POWER CONSUMPTION
       duplex') communications system.                                current (at 30 V DC)                 25 mA quiescent
                                                                                                           40 mA signalling
       Users of the system are connected via a 'party line'.                              135 mA at max. output + signalling
       Master stations (with built-in power supply), beltpacks,
       speaker stations and power supplies are                        MIC. PREAMP
       interconnected via standard microphone cable. One              mic. impedance                              200 ohms
       wire is used as an audio line, one as a power line and         gain              40 dB - 70 dB (adjustable internally)
       the screen of the cable functions as earth/return.             presence filter                        +6 dB at 5 kHz
                                                                      frequency response             200 Hz - 13 kHz (-3 dB)
       Current drive is used for signal transfer. Each station        V electret mic                                +9 V DC
       utilises a current amplifier to amplify the microphone
       signal and place it on the common audio line where,            HEADPHONES DRIVER AMP
       due to the constant line impedance (situated in the            max. load                            200 ohms
       power supply between XLR pin 3 and 1), a signal                max. output level          14 V rms (200 ohms)
       voltage is developed which can be further amplified            max. output power  0.5 W rms (each headset can)
       and sent to headphones or loudspeakers.
                                                                      INTERCOM LINE DRIVER
       This principle has three advantages:                           max. output current                           3 mA rms
       - the use of a single audio line allows several                output impedance                           > 150 Kohms
          stations to talk and listen simultaneously.
       - due to the high bridging impedance offered by                SIDETONE
          each station, the number of stations 'on line' has          rejection                           0 - 30dB adjustable
          no influence on the level of the communications
          signal.                                                     BUZZER
       - power and audio to the intercom stations use the             max. SPL                                       114 dBA
          same cable.
                                                                      DIMENSIONS AND WEIGHT
       The Call signal is also sent as a current on the audio         width                                            90 mm
       line. It develops a DC potential over the line impedance       height                                           38 mm
       which will be sensed by each station and interpreted           depth                                           124 mm
       as a Call signal.                                              weight                                            295 g

                                                                      GENERAL SYSTEM SPECIFICATIONS
                                                                      intercom line impedance             350 ohms (1kHz)
                                                                                                           2.2 Kohms (DC)
                                                                      intercom line audio level              nom. -18 dBu
       9.0    GUARANTEE                                                                                       max. +4 dBu
                                                                      dynamic range                                  80 dB
       This unit is warranted by ASL Intercom to the original         call send signal                            +2.8 mA
       end-user purchaser against defects in workmanship              call receive signal threshold              +2.4 V DC
       and materials in it's manufacture for a period of one          supply voltage                +30 V DC (12 V to 32 V)
       year from date of shipment to the end-user.                    mic mute power interrupt time                 0.1 sec

       Faults arising from misuse, unauthorised
       modifications or accidents are not covered by this             Note: 0 dBu = 775 mV into open circuit
       warranty. If the unit is faulty it should be sent in it's
       original packing, to the supplier or your local ASL            ASL reserves the right to alter specifications without
       dealer, with shipping prepaid. A note must be included         further notice.
       stating the faults found and a copy of the original
       suppliers invoice.




       THIS PRODUCT WAS DESIGNED, DEVELOPED AND
       MANUFACTURED BY:
       AMPCO SOUND LAB BV
       MAARSSEN (UTRECHT) HOLLAND.



User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.                                                        7
8   User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.   9
10   User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.   11

More Related Content

PDF
ASL Intercom PS19A
PDF
ASL Intercom PS29M
PDF
ASL Intercom PS29
PDF
ASL Intercom PS630
PDF
ASL Intercom BS15
PDF
ASL Intercom PS230
PDF
ASL Intercom PS430
PDF
ASL Intercom PS130
ASL Intercom PS19A
ASL Intercom PS29M
ASL Intercom PS29
ASL Intercom PS630
ASL Intercom BS15
ASL Intercom PS230
ASL Intercom PS430
ASL Intercom PS130

Viewers also liked (17)

PDF
Sound Devices 552
PDF
ASL Intercom PS130
PDF
ASL Intercom BS216
PDF
Sony HVR-Z5E
PDF
Sound Devices 702T
PDF
Sony HVR-S270E
PDF
AJA HDP2
PDF
ASL Intercom PS680
PDF
Sony LMD 940W
PDF
Sony LMD-1530W
PDF
Datavideo DAC-50
PDF
Secced Techno12
PDF
Edirol V-440HD
PDF
AJA Kipro Mini
PDF
Kona 3G
PDF
PSC Pro Mix 6
PDF
ASL Intercom PS285
Sound Devices 552
ASL Intercom PS130
ASL Intercom BS216
Sony HVR-Z5E
Sound Devices 702T
Sony HVR-S270E
AJA HDP2
ASL Intercom PS680
Sony LMD 940W
Sony LMD-1530W
Datavideo DAC-50
Secced Techno12
Edirol V-440HD
AJA Kipro Mini
Kona 3G
PSC Pro Mix 6
ASL Intercom PS285
Ad

Similar to ASL Intercom PS19M (20)

PDF
ASL Intercom PS19A
PDF
ASL Intercom PS 19A
PDF
ASL Intercom PS29
PDF
ASL Intercom PS 29
PDF
ASL Intercom PS29M
PDF
ASL Intercom PS 29 M
PDF
ASL Intercom PS630
PDF
ASL Intercom PS 630
PDF
ASL Intercom PS 130
PDF
ASL Intercom PS430
PDF
ASL Intercom PS 430
PDF
ASL Intercom PS230
PDF
ASL Intercom PS 230
PDF
ASL Intercom PS-19AM 1-channel beltpacks wth program (AUX) input
PDF
ASL Intercom BS15
PDF
ASL Intercom BS 15
PDF
ASL Intercom PS155
PDF
ASL Intercom PS155
PDF
ASL Intercom PS 155
PDF
ASL Intercom BS216
ASL Intercom PS19A
ASL Intercom PS 19A
ASL Intercom PS29
ASL Intercom PS 29
ASL Intercom PS29M
ASL Intercom PS 29 M
ASL Intercom PS630
ASL Intercom PS 630
ASL Intercom PS 130
ASL Intercom PS430
ASL Intercom PS 430
ASL Intercom PS230
ASL Intercom PS 230
ASL Intercom PS-19AM 1-channel beltpacks wth program (AUX) input
ASL Intercom BS15
ASL Intercom BS 15
ASL Intercom PS155
ASL Intercom PS155
ASL Intercom PS 155
ASL Intercom BS216
Ad

More from AV ProfShop (20)

PDF
Decimator MD-HX hardware-manual_fv1.3
PDF
Panasonic AV-HS410 Multiformat Vision Mixer HD/SD
PDF
Panasonic AW-HE40SW/SK/HW/HK PTZ Camera with HD-SDI / HDMI Output
PDF
Sony MCX-500 Live Production Switcher
PDF
JVC GY-HM200 GY-HM170 Brochure AVProfShop
PDF
JVC GY-HM620 Brochure AVProfShop
PDF
JVC GY-HM660 Brochure AVProfShop
PDF
Datavideo TP Kit (Teleprompter) Brochure
PDF
Datavideo MS-2800 Brochure
PDF
Datavideo HS-2800 Brochure
PDF
Datavideo CG-350 Brochure
PDF
Datavideo DVK-200 Brochure
PDF
Datavideo ITC-100 Brochure
PDF
Datavideo RMC-180 Brochure
PDF
Datavideo HS-600 Hand Carry System Brochure
PDF
Datavideo SE-600 Brochure
PDF
Datavideo SE-500 Brochure
PDF
Atomos Range Brochure
PDF
Sony PXW-Z450
PDF
Datavideo SE-2200 6 input HD broadcast quality switcher
Decimator MD-HX hardware-manual_fv1.3
Panasonic AV-HS410 Multiformat Vision Mixer HD/SD
Panasonic AW-HE40SW/SK/HW/HK PTZ Camera with HD-SDI / HDMI Output
Sony MCX-500 Live Production Switcher
JVC GY-HM200 GY-HM170 Brochure AVProfShop
JVC GY-HM620 Brochure AVProfShop
JVC GY-HM660 Brochure AVProfShop
Datavideo TP Kit (Teleprompter) Brochure
Datavideo MS-2800 Brochure
Datavideo HS-2800 Brochure
Datavideo CG-350 Brochure
Datavideo DVK-200 Brochure
Datavideo ITC-100 Brochure
Datavideo RMC-180 Brochure
Datavideo HS-600 Hand Carry System Brochure
Datavideo SE-600 Brochure
Datavideo SE-500 Brochure
Atomos Range Brochure
Sony PXW-Z450
Datavideo SE-2200 6 input HD broadcast quality switcher

Recently uploaded (20)

PDF
Stacey L Stevens - Canada's Most Influential Women Lawyers Revolutionizing Th...
PDF
Immigration Law and Communication: Challenges and Solutions {www.kiu.ac.ug)
DOCX
Handbook of Entrepreneurship- Chapter 5: Identifying business opportunity.docx
PPTX
Understanding Procurement Strategies.pptx Your score increases as you pick a ...
PDF
Robin Fischer: A Visionary Leader Making a Difference in Healthcare, One Day ...
DOCX
ola and uber project work (Recovered).docx
PPTX
IMM.pptx marketing communication givguhfh thfyu
PDF
Pink Cute Simple Group Project Presentation.pdf
PPTX
IMM marketing mix of four ps give fjcb jjb
DOCX
80 DE ÔN VÀO 10 NĂM 2023vhkkkjjhhhhjjjj
PDF
HQ #118 / 'Building Resilience While Climbing the Event Mountain
PDF
Engaging Stakeholders in Policy Discussions: A Legal Framework (www.kiu.ac.ug)
PDF
Vinod Bhatt - Most Inspiring Supply Chain Leader in India 2025.pdf
PDF
Cross-Cultural Leadership Practices in Education (www.kiu.ac.ug)
PDF
Second Hand Fashion Call to Action March 2025
PPTX
CTG - Business Update 2Q2025 & 6M2025.pptx
PPT
Retail Management and Retail Markets and Concepts
DOCX
Hand book of Entrepreneurship 4 Chapters.docx
PDF
Handouts for Housekeeping.pdfhsjsnvvbdjsnwb
PPT
BCG内部幻灯片撰写. slide template BCG.slide template
Stacey L Stevens - Canada's Most Influential Women Lawyers Revolutionizing Th...
Immigration Law and Communication: Challenges and Solutions {www.kiu.ac.ug)
Handbook of Entrepreneurship- Chapter 5: Identifying business opportunity.docx
Understanding Procurement Strategies.pptx Your score increases as you pick a ...
Robin Fischer: A Visionary Leader Making a Difference in Healthcare, One Day ...
ola and uber project work (Recovered).docx
IMM.pptx marketing communication givguhfh thfyu
Pink Cute Simple Group Project Presentation.pdf
IMM marketing mix of four ps give fjcb jjb
80 DE ÔN VÀO 10 NĂM 2023vhkkkjjhhhhjjjj
HQ #118 / 'Building Resilience While Climbing the Event Mountain
Engaging Stakeholders in Policy Discussions: A Legal Framework (www.kiu.ac.ug)
Vinod Bhatt - Most Inspiring Supply Chain Leader in India 2025.pdf
Cross-Cultural Leadership Practices in Education (www.kiu.ac.ug)
Second Hand Fashion Call to Action March 2025
CTG - Business Update 2Q2025 & 6M2025.pptx
Retail Management and Retail Markets and Concepts
Hand book of Entrepreneurship 4 Chapters.docx
Handouts for Housekeeping.pdfhsjsnvvbdjsnwb
BCG内部幻灯片撰写. slide template BCG.slide template

ASL Intercom PS19M

  • 1. PRO SERIES USER MANUAL FOR THE PS 19 M SINGLE CHANNEL BELTPACK CONTENTS 1.0 GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . 3 2.0 UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3.0 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4.0 FRONT PANEL CONTROLS . . . . . . . . . . . . . . . . . . . . 4 5.0 REAR PANEL CONNECTORS . . . . . . . . . . . . . . . . . . . 4 6.0 BOTTOM CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . 5 7.0 CABLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 8.0 PARTY LINE, TECHNICAL CONCEPT . . . . . . . . . . . . 7 9.0 GUARANTEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 10.0 TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . 7 User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
  • 2. 2 User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
  • 3. 1.0 GENERAL DESCRIPTION The PS 19M is a portable single channel user station. The unique ASL CALL system provides both a flashing It is housed in a strong aluminium case and is red LED and a very distinctive and characteristic provided with a steel beltclip. sound signal. Smooth operation is guaranteed with the CALL button. A momentary push makes the extra On the front panel are a Volume (listen level) control, a bright red LED flash, whilst holding the button for two Talk and a Call button with LED indicators. seconds will activate the CALL sound signal. The volume of the sound signal (buzzer) can be adjusted at Special attention has been paid to the intelligibility of the front panel. speech. By applying low noise/high speed opamps, a speech presence filter and a specially developed high Fully electronic switching increases reliability and power bridged headphone amplifier, communication is allows for : very comfortable even in environments with high - 'soft' microphone ON switching, latched or background noise level. momentary - remote Mic Mute facility. 2.0 UNPACKING The shipping carton contains the parts listed below After unpacking the unit please inspect for any * The PS 19M physical damage to the unit, and retain the shipping * User manual carton and relevant packing materials for use should If any are missing, contact your dealer. the unit need returning. ASL has taken great care to ensure this product If any damage has occured, please notify your dealer reaches you in flawless condition. immediately so that a written claim can be initiated. Please also refer to the guarantee section of this manual. 3.0 INSTALLATION This PS 19M will form part of an existing or new To connect the PS 19M onto the intercom system, use intercom system, and connection to it is straightfor- professional flexible microphone cable with 2 wires ward. There are no separate power connections, or and 1 shield only. Connect the system intercom cable batteries to install, as the necessary DC voltages are into the LINE connector socket on the rear panel. derived from the intercom master station or power Finally connect the listening headset plug into the supply, via the intercom connection cable. HEADSET connector, also on the rear panel. The PS 19M is fully protected against mis-wiring (reverse power) or short-circuit in the interconnecting cables. User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland. 3
  • 4. 4.0 FRONT PANEL CONTROLS 1 VOLUME control knob This knob adjusts the listen level for the headset. 2 TALK button This push button activates the headset microphone, the bright green LED(4) indicates if the microphone is switched on. Latched switching: When a TALK button is pressed quickly, the microphone will be switched on, and is electronically latched. When pressed again, the microphone will be switched off. Momentary switching: When a TALK button is pressed and held, the microphone will be active until the button is released. When the microphone is latched on, it can be muted by a Mic Mute from a PRO Series master station or power supply. 3 CALL button This push button activates the call system. A momentary push will send a call signal to all stations connected to the intercom channel and the call LEDS will start flashing. Press and hold the button for 2 seconds will activate the call buzzer, if not muted. After the CALL button is released the LEDS will continue to flash for further 2 seconds. 5.0 REAR PANEL CONNECTORS 4 LINE connectors These XLR-3 connectors are for connecting the PS 19M to the intercom system. Pin assignments : 1. 0 V / ground shield 2. +30 V power wire 3. audio wire The female connector is for input. The male connector is for extending the intercom line to other user stations. 5 HEADSET connector An XLR-4 type connector for the connection of the local headset. This must have a can impedance of 200 ohms (or greater), or each 400 ohms minimum when in parallel. The mic may be of the dynamic or electret type. Pin assignments : 1. Shield mic. (GND) 2. mic. + 3. phones + 4. phones - 4 User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
  • 5. 6.0 BOTTOM CONTROLS 4 MIC GAIN The mic gain can be adjusted internally by a trimmer. 6 BUZZER VOLUME trimmer This trimmer adjusts the volume of the internal - Open the PS 19M by removing the four screws buzzer, which is located behind the front panel. on the under side. The buzzer is activated if you press the CALL - The trimmer is located on the lower PCB board. button of the PS 19 (3) or a CALL button of any other station (on the channel to which the PS 19M To increase mic gain turn clockwise. is connected), longer than 2 seconds and the To decrease mic gain turn counterclockwise. buzzers are not muted (on the master station or power supply). 5 SIDETONE trimmer This trimmer adjusts the level of your own voice as you hear it in your headset. Adjustment procedure : - set trimmer in start position : fully clockwise. - switch off the microphone of all connected (speaker!) stations. - switch on the microphone of the PS 19. - turn up volume. - speak into the headset microphone. - adjust the listen level by turning the sidetone trimmer. The operating area is between fully clockwise and minimum level. Adjusting the sidetone does not affect the level of your voice as it is heard by other stations. User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland. 5
  • 6. 7.0 CABLING For the PRO Series Intercom system the interconnecting cables are of the shielded two- conductor microphone cable type and the intercom line connectors are of the XLR-3 type. Audio and Call signals are on XLR pin 3, DC power is on XLR pin 2. XLR pin 1 is connected to the shield of the cable which functions as the common return for audio and power. Since the audio signal is transferred in an unbalanced þ way, certain rules have to be obeyed when installing the cables of an intercom network. This is to avoid earth loops and to minimize power loss and the possible effect of electromagnetic fields. These rules are: þ Use high quality (multipair) cable. þ Keep cables parallel as much as possible. For interconnecting user stations, power supplies When two (multi channel) units in a network are and accessories in an ASL Intercom network, use connected by more than one cable, make sure that high quality shielded two-conductor (minimum 2x these cables are parallel to each other over the 0.30 mm2) microphone cable only. whole distance between those units. When using In case of a multi channel intercom network, use multipair cable, parallelism is ensured in the best high quality microphone 'multipair' cable only, each possible way. pair consisting of two conductors (minimum 2x 0.15 mm2) with separate shield. Multipair cable þ Avoid closed loops. should also have an overall shield. Always avoid that cables are making a loop. So- called 'ring intercom' should not physically be þ Use flexible cables. cabled as a ring. All cable routes should have a Use flexible single and multipair microphone cable 'star' configuration, with the central earthing point instead of cable with solid cores, especially when (usually close to the power supply position) as the the cable is subjected to bending during operation center of the star. or installation. þ Keep cables away from electromagnetic sources. þ Separate cable screen to XLR pin 1. Keep intercom cables away from high energy The screen of each separate microphone cable cables, e.g. 110/220/380V mains power or dimmer and/or the screen of each single pair in a multipair controlled feeds for spotlights. cable, should be connected to pin 1 of each XLR-3 Intercom cables should cross high energy cables connector. Do not connect this cable screen to the at an angle of 90þ only. metal housing of the connector or to metal wall Intercom cables should never be in the same boxes (outlets). trunking as energy cables. See page 10: Earthing Concept. þ Place power supply in a central position. þ Cable trunks, connection boxes and overall In order to avoid unacceptable power losses, place multipair cable screen to clean earth. the power supply as close as possible to where Metal cable trunks, metal connection boxes and most power consumption occurs or, in other overall multipair cable screen should be inter- words, most user stations are placed. connected and, at one point (the 'central earthing point') in the intercom network only, be connected þ Connect ASL power supply to a 'clean' mains to a clean earth or a safety earth. outlet. See page 10: Earthing Concept. The ASL power supply may be connected to the mains power outlet to which other audio equipment þ Keep metal connection boxes and cable housings is connected. Avoid using mains outlets which also isolated from other metal parts. power dimmer controlled lighting systems. Metal housings for intercom cables and connectors should be mounted in such a way that they are In case of more complex installations, don't isolated from other metal cable and connector hesitate to contact us. Please send us a block housings and from any other metal construction diagram of the planned network with a list of all parts. user stations and their positions, and we are happy to advise you on cabling lay out. þ See Party Line, Technical Concept 6 User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
  • 7. 8.0 PARTY LINE, TECHNICAL CONCEPT 10.0 TECHNICAL SPECIFICATIONS PS 19M ASL's PRO Series offers a complete two way ('full POWER CONSUMPTION duplex') communications system. current (at 30 V DC) 25 mA quiescent 40 mA signalling Users of the system are connected via a 'party line'. 135 mA at max. output + signalling Master stations (with built-in power supply), beltpacks, speaker stations and power supplies are MIC. PREAMP interconnected via standard microphone cable. One mic. impedance 200 ohms wire is used as an audio line, one as a power line and gain 40 dB - 70 dB (adjustable internally) the screen of the cable functions as earth/return. presence filter +6 dB at 5 kHz frequency response 200 Hz - 13 kHz (-3 dB) Current drive is used for signal transfer. Each station V electret mic +9 V DC utilises a current amplifier to amplify the microphone signal and place it on the common audio line where, HEADPHONES DRIVER AMP due to the constant line impedance (situated in the max. load 200 ohms power supply between XLR pin 3 and 1), a signal max. output level 14 V rms (200 ohms) voltage is developed which can be further amplified max. output power 0.5 W rms (each headset can) and sent to headphones or loudspeakers. INTERCOM LINE DRIVER This principle has three advantages: max. output current 3 mA rms - the use of a single audio line allows several output impedance > 150 Kohms stations to talk and listen simultaneously. - due to the high bridging impedance offered by SIDETONE each station, the number of stations 'on line' has rejection 0 - 30dB adjustable no influence on the level of the communications signal. BUZZER - power and audio to the intercom stations use the max. SPL 114 dBA same cable. DIMENSIONS AND WEIGHT The Call signal is also sent as a current on the audio width 90 mm line. It develops a DC potential over the line impedance height 38 mm which will be sensed by each station and interpreted depth 124 mm as a Call signal. weight 295 g GENERAL SYSTEM SPECIFICATIONS intercom line impedance 350 ohms (1kHz) 2.2 Kohms (DC) intercom line audio level nom. -18 dBu 9.0 GUARANTEE max. +4 dBu dynamic range 80 dB This unit is warranted by ASL Intercom to the original call send signal +2.8 mA end-user purchaser against defects in workmanship call receive signal threshold +2.4 V DC and materials in it's manufacture for a period of one supply voltage +30 V DC (12 V to 32 V) year from date of shipment to the end-user. mic mute power interrupt time 0.1 sec Faults arising from misuse, unauthorised modifications or accidents are not covered by this Note: 0 dBu = 775 mV into open circuit warranty. If the unit is faulty it should be sent in it's original packing, to the supplier or your local ASL ASL reserves the right to alter specifications without dealer, with shipping prepaid. A note must be included further notice. stating the faults found and a copy of the original suppliers invoice. THIS PRODUCT WAS DESIGNED, DEVELOPED AND MANUFACTURED BY: AMPCO SOUND LAB BV MAARSSEN (UTRECHT) HOLLAND. User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland. 7
  • 8. 8 User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
  • 9. User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland. 9
  • 10. 10 User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland.
  • 11. User Manual PS 19M / Issue 1 © 1999 ASL Intercom, Utrecht, Holland. 11