SlideShare a Scribd company logo
approval
Products	Solutions	 Services
Application / FunctionOverview Technical data Dimensions
Electrical connection Price table Contact
Go to
shop
Technical Datasheet
TD 00035E/24/EN/01.13
•	 Suitable for hygienic applications
•	 38 mm (1.5") fork, surface
roughness Ra≤ 1.5 µm
•	 Rugged stainless steel housing
(316L) with M12×1 plug
•	 IP 69K protection
•	 External test possible using test
magnet
•	 Suitable for CIP and SIP applications
Complete product information:
www.e-direct.us/ftl20h
Specs at a glance:
•	Product: Liquids
•	Mounting:
Vessels or pipes (from DN25)
•	Product density:
≥ 0.7 g/cm³ (0.7 SGU)
•	Product temperature:
-40 to +300 °F (-40 to +150 °C)
•	Product viscosity:
≤ 10000 mm²/s (10000 cSt)
•	Process pressure:
-14.5 to 580 psi (-1 to +40 bar)
Hygienic vibronic point level switch for liquids
Liquiphant T FTL20H
$ 249.00
Liquiphant T FTL20H:
programmable logic controller
(PLC), relay, solenoid valve or
AS-i bus
~ 230 V
PLC
AS-Interface
U
Liquiphant T FTL20H 2
Overview Technical data Dimensions
Electrical connection Price table Contact
Go to
shop
Application / Function
Application Liquiphant T FTL20H is
a reliable point level switch for liquids.
Its 38 mm (1.5") fork and its small
process connections enable mounting
it also in tanks as in very narrow pipes
for example as pump protection which
have to meet particularly high
hygienic standards internally and
externally. The FTL20H is unaffected
by build up, bubbles or turbulence and
does not rely upon the electrical
properties of the liquid.
Application exampleFunction The integrated electronics
detect the change in the fork’s
vibrating frequency when they are
covered and uncovered by the liquid.
FTL20H can be directly connected to
AS-i bus, alternating voltage or to a
PLC.
Liquiphant T FTL20H 3
Application / FunctionOverview
Electrical connection Price table Contact
Go to
shop
Technical data Dimensions
Output AC version
Power supply 19 to 253 V AC, 50/60 Hz
Connectable load Max.250 mA (load is checked automatically
when connected)
Current consumption Max. 3.8 mA
Electrical connection Valve connector
Output DC version
Power supply 10 to 35 V DC
Connectable load Max. 250 mA
Current consumption Max. 15 mA
Electrical connection Valve connector or M12×1
AS-i bus
Power supply 24.5 to 31 V DC
Connectable load To EN 50295
Current consumption Max. 25 mA
Electrical connection M12×1
Output general
Switching time Approx. 0.5 s when covered; approx. 1.0 s
when free
Hysteresis 3 ± 0.5 mm (0.12” ± 0.02”) vertical from top
Process connection G ¾” flush mounted (for welding
52018765);
G 1” flush mounted (for welding 52001051);
TRI-CLAMP® ISO 2852 DN40-51 (2”);
DIN 11851 DN25 PN40;
DIN 11851 DN32 PN40
Technical data
Operating conditions
Orientation As required
Switch point Vertical orientation: 13 mm (0.51”);
horizontal orientation: 3.5 mm (0.14”)
Ambient temperature -40 to +158 °F (-40 to +70 °C)
Temperature of
product
-40 to +300 °F (-40 to +150 °C)
Operating pressure -14.5 to +580 psi (-1 to +40 bar)
Storage temperature -40 to +185 °F (-40 to +85 °C)
Density of product Min. 0.7 g/cm³(0.7 SGU)
Viscosity of product Up to 10000 mm²/s (cSt)
Protection
(EN 60529)
IP 65 with valve connector;
IP 66/67 with M12×1 connector;
IP 69K with M12×1 metal
Climatic protection IEC 68, part 2-38
EMC Interference emission to EN 61326 Class B;
interference immunity to EN 61326 Annex A
(industrial) NAMUR NE 21; AS-i to
EN 50295
Approvals
WHG approval Overspill protection to §19 WHG (Germany)
EHEDG
Dimensions (in inches)
6.81
7.30
M12×1
General
Valve plug
*1 Switch point with vertical installation
*2 Switch point with horizontal installation
Installation according to instruction manual
32 AF
32 AF
Ø1.57
1.57
1.18
Ø0.67Ø0.67
0.51 *¹
0.51 *¹
Ø1.24
Ø1.24
0.14*²0.14*²
1.50
1.50
1.42
2.03
G ¾ (DIN ISO 228/I)
Process connections
4.28
1.50 0.63
3.662.52
0.89
0.89
32AF
1.89
Tri-Clamp (ISO 2852)
Liquiphant T FTL20H 4
Application / FunctionOverview Technical data Dimensions
Contact
Go to
shopElectrical connection Price table
Price table
More products to complete your measuring point …
Liquiphant FTL20H Order no. Price/pcs. in USD
Switch Output Application; Cable Entry Process Connection 1 to 5 6 to 10 11 to 35
2-wire
19-253 V AC
150 °C;
plug ISO4400 NPT½, IP65
Tri-Clamp ISO2852 DN25-38
(1...1½"), 316L
FTL20H-3TCJ1C 307.00 286.00 270.00
Tri-Clamp ISO2852 DN40-51
(2"), 316L
FTL20H-3TDJ1C 307.00 286.00 270.00
3-wire PNP
10-35 V DC
150 °C;
plug ISO4400 NPT½, IP65
Tri-Clamp ISO2852 DN25-38
(1...1½"), 316L
FTL20H-3TCJ2C 307.00 286.00 270.00
Tri-Clamp ISO2852 DN40-51
(2"), 316L
FTL20H-3TDJ2C 307.00 286.00 270.00
150 °C;
plug M12, IP69K
Thread ISO228 G¾, 316L * FTL20H-3GDJ2F 284.00 264.00 249.00
Tri-Clamp ISO2852 DN25-38
(1...1½"), 316L
FTL20H-3TCJ2F 331.00 307.00 291.00
Tri-Clamp ISO2852 DN40-51
(2"), 316L
FTL20H-3TDJ2F 331.00 307.00 291.00
* Please order accessory weld-in adapter separately.
Accessories Order no. Price/pcs. in USD
Socket wrench 32AF 52010156 13.00
Cable 4 × 0.34, box M12, Cu Sn/Ni, 90°, L = 5 m
M12 socket for plug. 5 m cable PVC, Cu Sn/Ni lock.
52010285 13.00
Weld-in adapter G¾ d=50, 316L, 3.1 52018765 60.00
Prices valid until 09.30.2013 in U.S. dollars per unit (not including shipping and applicable sales tax).
See Endress+Hauser, Inc. Terms and Conditions of Sale for shipping, tax, and payment terms.
Complete product information:
www.e-direct.us/ftl20h
Electrical connection
DC-PNP
with M12 × 1
connector
DC-PNP
with valve
connector
AC two-wire
with valve
connector
AS-i
with M12 × 1
connector
12
4
AS-i + 1: BN
3: BU
AS-i –
3
12
43
R
L– L+
0,5 A
1: BN
3: BU
4: BK
12
43
R
L– L+
0,5 A
1: BN
2: WT
3: BU
1 2
+
–
3 R
L–PE L+
0,5 A
1 2
+
–
3
R
L–PE L+
0,5 A
1
>19 V
3
R
L1PE N
0,5 A
1
>19 V
2
R
L1PE N
0,5 A
Max.	Min.
Temperature switch
Thermophant T TTR35
Compact thermometer
Easytemp TMR35
Pressure transmitter
Cerabar T PMP135
Application / FunctionOverview Technical data Dimensions
Electrical connection Price table Contact
Go to
shop
Contact
E-direct
Endress+Hauser, Inc.
2350 Endress Place
Greenwood, IN 46143
Direct order
Internet	www.e-direct.us
by phone	 888-EH-DIRECT
(343-4732)
per Fax	 317-535-8498
E-Mail	e-direct@us.endress.com

More Related Content

What's hot (20)

PDF
Anti vandal switch
PDF
Piezo switch
PDF
MHC-3000 Wall mount ultrasonic flow meter data sheet
PDF
Electromagnetic Flow Monitor Magphant
PDF
Codatron ht high voltage regulators
PDF
Hsm20g datasheet
PDF
Turbimax cus31 endress+hauser datasheet-turbidity sensor
PDF
vertical autoclave suplier in GZB
PDF
Magnetostrictive Liquid Level Transmitters
PDF
Zirconia oxygen sensors (zirconia o2 sensor) o2 s-t2 o2s-fr-t2
PDF
Mod mag m1000 datasheet badger meter electromagnetic flow meter_m-series
PDF
Innovations 2016 English
PDF
Environmental sensors
PDF
Mod mag m7600 datasheet badger meter electromagnetic flow meter_m-series
Anti vandal switch
Piezo switch
MHC-3000 Wall mount ultrasonic flow meter data sheet
Electromagnetic Flow Monitor Magphant
Codatron ht high voltage regulators
Hsm20g datasheet
Turbimax cus31 endress+hauser datasheet-turbidity sensor
vertical autoclave suplier in GZB
Magnetostrictive Liquid Level Transmitters
Zirconia oxygen sensors (zirconia o2 sensor) o2 s-t2 o2s-fr-t2
Mod mag m1000 datasheet badger meter electromagnetic flow meter_m-series
Innovations 2016 English
Environmental sensors
Mod mag m7600 datasheet badger meter electromagnetic flow meter_m-series
Ad

Similar to FTL20H (20)

PDF
Level limit switch compact design-Liquiphant T FTL20H
PDF
Liquipoint t ftw31 32 endress+hauser datasheet-level limit switch for multipl...
PDF
T switch - att11-endress+hauser datasheet-thermal flow switch
PDF
Liquiphant M Density and Density Computer FML621
PDF
Flameproof Hydraulic Range Pressure Switches FC series
PDF
Liquiphant m density densitycontroller fml621 endress+hauser datasheet
PDF
Electromagnetic flowmeter - Proline Promag 10H
PDF
Waterpilot fmx167 endress+hauser datasheet-hydrostatic level measurement
PPTX
Manual Valve Applications Dealers In India
PDF
Guided Level Radar-Levelflex M FMP40
PDF
180625_W600 PH WCT DIS Wall Mount
PDF
Ga dat cam bien
PDF
Proline Promag 10L-Electromagnetic Flowmeter
PDF
Proline promag 10 l endress+hauser datasheet-electromagnetic flowmeter
PDF
Vortex Valves - Handling Dry Solids
PDF
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
PDF
Proline promag 10 p endress+hauser datasheet-electromagnetic flowmeter
PDF
Proline Promag 10P-Electromagnetic Flowmeter
Level limit switch compact design-Liquiphant T FTL20H
Liquipoint t ftw31 32 endress+hauser datasheet-level limit switch for multipl...
T switch - att11-endress+hauser datasheet-thermal flow switch
Liquiphant M Density and Density Computer FML621
Flameproof Hydraulic Range Pressure Switches FC series
Liquiphant m density densitycontroller fml621 endress+hauser datasheet
Electromagnetic flowmeter - Proline Promag 10H
Waterpilot fmx167 endress+hauser datasheet-hydrostatic level measurement
Manual Valve Applications Dealers In India
Guided Level Radar-Levelflex M FMP40
180625_W600 PH WCT DIS Wall Mount
Ga dat cam bien
Proline Promag 10L-Electromagnetic Flowmeter
Proline promag 10 l endress+hauser datasheet-electromagnetic flowmeter
Vortex Valves - Handling Dry Solids
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
Proline promag 10 p endress+hauser datasheet-electromagnetic flowmeter
Proline Promag 10P-Electromagnetic Flowmeter
Ad

More from E-direct, Division of Endress+Hauser (20)

Recently uploaded (20)

PPTX
Chapter no 8 output devices dpart 2.pptx
PPTX
Growth Capital Investment - Espresso Capital.pptx
PPTX
New professional education PROF-ED-7_103359.pptx
PPTX
Subordinate_Clauses_BlueGradient_Optimized.pptx
PDF
2- Physical Layer (06).pdfgshshshbsbshshshhs
PPTX
rorakshsjppaksvsjsndjdkndjdbdidndjdbdjom.pptx
PPTX
PLC ANALOGUE DONE BY KISMEC KULIM TD 5 .0
PPTX
Computers and mobile device: Evaluating options for home and work
PDF
GENERATOR AND IMPROVED COIL THEREFOR HAVINGELECTRODYNAMIC PROPERTIES
PPTX
Unit-1.pptxgeyeuueueu7r7r7r77r7r7r7uriruru
PPTX
AI_ML_Internship_WReport_Template_v2.pptx
PPT
System Unit Components and its Functions
PDF
Dozuki_Solution-hardware minimalization.
PPTX
Clauses_Part1.hshshpjzjxnznxnxnndndndndndndndnndptx
PDF
Presented by ATHUL KRISHNA.S_20250813_191657_0000.pdf
PPTX
vortex flow measurement in instrumentation
PDF
Topic-1-Main-Features-of-Data-Processing.pdf
PDF
ICT grade for 8. MATATAG curriculum .P2.pdf
PPTX
A Clear View_ Interpreting Scope Numbers and Features
PDF
Maxon CINEMA 4D 2025 Crack Free Download Latest Version
Chapter no 8 output devices dpart 2.pptx
Growth Capital Investment - Espresso Capital.pptx
New professional education PROF-ED-7_103359.pptx
Subordinate_Clauses_BlueGradient_Optimized.pptx
2- Physical Layer (06).pdfgshshshbsbshshshhs
rorakshsjppaksvsjsndjdkndjdbdidndjdbdjom.pptx
PLC ANALOGUE DONE BY KISMEC KULIM TD 5 .0
Computers and mobile device: Evaluating options for home and work
GENERATOR AND IMPROVED COIL THEREFOR HAVINGELECTRODYNAMIC PROPERTIES
Unit-1.pptxgeyeuueueu7r7r7r77r7r7r7uriruru
AI_ML_Internship_WReport_Template_v2.pptx
System Unit Components and its Functions
Dozuki_Solution-hardware minimalization.
Clauses_Part1.hshshpjzjxnznxnxnndndndndndndndnndptx
Presented by ATHUL KRISHNA.S_20250813_191657_0000.pdf
vortex flow measurement in instrumentation
Topic-1-Main-Features-of-Data-Processing.pdf
ICT grade for 8. MATATAG curriculum .P2.pdf
A Clear View_ Interpreting Scope Numbers and Features
Maxon CINEMA 4D 2025 Crack Free Download Latest Version

FTL20H

  • 1. approval Products Solutions Services Application / FunctionOverview Technical data Dimensions Electrical connection Price table Contact Go to shop Technical Datasheet TD 00035E/24/EN/01.13 • Suitable for hygienic applications • 38 mm (1.5") fork, surface roughness Ra≤ 1.5 µm • Rugged stainless steel housing (316L) with M12×1 plug • IP 69K protection • External test possible using test magnet • Suitable for CIP and SIP applications Complete product information: www.e-direct.us/ftl20h Specs at a glance: • Product: Liquids • Mounting: Vessels or pipes (from DN25) • Product density: ≥ 0.7 g/cm³ (0.7 SGU) • Product temperature: -40 to +300 °F (-40 to +150 °C) • Product viscosity: ≤ 10000 mm²/s (10000 cSt) • Process pressure: -14.5 to 580 psi (-1 to +40 bar) Hygienic vibronic point level switch for liquids Liquiphant T FTL20H $ 249.00
  • 2. Liquiphant T FTL20H: programmable logic controller (PLC), relay, solenoid valve or AS-i bus ~ 230 V PLC AS-Interface U Liquiphant T FTL20H 2 Overview Technical data Dimensions Electrical connection Price table Contact Go to shop Application / Function Application Liquiphant T FTL20H is a reliable point level switch for liquids. Its 38 mm (1.5") fork and its small process connections enable mounting it also in tanks as in very narrow pipes for example as pump protection which have to meet particularly high hygienic standards internally and externally. The FTL20H is unaffected by build up, bubbles or turbulence and does not rely upon the electrical properties of the liquid. Application exampleFunction The integrated electronics detect the change in the fork’s vibrating frequency when they are covered and uncovered by the liquid. FTL20H can be directly connected to AS-i bus, alternating voltage or to a PLC.
  • 3. Liquiphant T FTL20H 3 Application / FunctionOverview Electrical connection Price table Contact Go to shop Technical data Dimensions Output AC version Power supply 19 to 253 V AC, 50/60 Hz Connectable load Max.250 mA (load is checked automatically when connected) Current consumption Max. 3.8 mA Electrical connection Valve connector Output DC version Power supply 10 to 35 V DC Connectable load Max. 250 mA Current consumption Max. 15 mA Electrical connection Valve connector or M12×1 AS-i bus Power supply 24.5 to 31 V DC Connectable load To EN 50295 Current consumption Max. 25 mA Electrical connection M12×1 Output general Switching time Approx. 0.5 s when covered; approx. 1.0 s when free Hysteresis 3 ± 0.5 mm (0.12” ± 0.02”) vertical from top Process connection G ¾” flush mounted (for welding 52018765); G 1” flush mounted (for welding 52001051); TRI-CLAMP® ISO 2852 DN40-51 (2”); DIN 11851 DN25 PN40; DIN 11851 DN32 PN40 Technical data Operating conditions Orientation As required Switch point Vertical orientation: 13 mm (0.51”); horizontal orientation: 3.5 mm (0.14”) Ambient temperature -40 to +158 °F (-40 to +70 °C) Temperature of product -40 to +300 °F (-40 to +150 °C) Operating pressure -14.5 to +580 psi (-1 to +40 bar) Storage temperature -40 to +185 °F (-40 to +85 °C) Density of product Min. 0.7 g/cm³(0.7 SGU) Viscosity of product Up to 10000 mm²/s (cSt) Protection (EN 60529) IP 65 with valve connector; IP 66/67 with M12×1 connector; IP 69K with M12×1 metal Climatic protection IEC 68, part 2-38 EMC Interference emission to EN 61326 Class B; interference immunity to EN 61326 Annex A (industrial) NAMUR NE 21; AS-i to EN 50295 Approvals WHG approval Overspill protection to §19 WHG (Germany) EHEDG Dimensions (in inches) 6.81 7.30 M12×1 General Valve plug *1 Switch point with vertical installation *2 Switch point with horizontal installation Installation according to instruction manual 32 AF 32 AF Ø1.57 1.57 1.18 Ø0.67Ø0.67 0.51 *¹ 0.51 *¹ Ø1.24 Ø1.24 0.14*²0.14*² 1.50 1.50 1.42 2.03 G ¾ (DIN ISO 228/I) Process connections 4.28 1.50 0.63 3.662.52 0.89 0.89 32AF 1.89 Tri-Clamp (ISO 2852)
  • 4. Liquiphant T FTL20H 4 Application / FunctionOverview Technical data Dimensions Contact Go to shopElectrical connection Price table Price table More products to complete your measuring point … Liquiphant FTL20H Order no. Price/pcs. in USD Switch Output Application; Cable Entry Process Connection 1 to 5 6 to 10 11 to 35 2-wire 19-253 V AC 150 °C; plug ISO4400 NPT½, IP65 Tri-Clamp ISO2852 DN25-38 (1...1½"), 316L FTL20H-3TCJ1C 307.00 286.00 270.00 Tri-Clamp ISO2852 DN40-51 (2"), 316L FTL20H-3TDJ1C 307.00 286.00 270.00 3-wire PNP 10-35 V DC 150 °C; plug ISO4400 NPT½, IP65 Tri-Clamp ISO2852 DN25-38 (1...1½"), 316L FTL20H-3TCJ2C 307.00 286.00 270.00 Tri-Clamp ISO2852 DN40-51 (2"), 316L FTL20H-3TDJ2C 307.00 286.00 270.00 150 °C; plug M12, IP69K Thread ISO228 G¾, 316L * FTL20H-3GDJ2F 284.00 264.00 249.00 Tri-Clamp ISO2852 DN25-38 (1...1½"), 316L FTL20H-3TCJ2F 331.00 307.00 291.00 Tri-Clamp ISO2852 DN40-51 (2"), 316L FTL20H-3TDJ2F 331.00 307.00 291.00 * Please order accessory weld-in adapter separately. Accessories Order no. Price/pcs. in USD Socket wrench 32AF 52010156 13.00 Cable 4 × 0.34, box M12, Cu Sn/Ni, 90°, L = 5 m M12 socket for plug. 5 m cable PVC, Cu Sn/Ni lock. 52010285 13.00 Weld-in adapter G¾ d=50, 316L, 3.1 52018765 60.00 Prices valid until 09.30.2013 in U.S. dollars per unit (not including shipping and applicable sales tax). See Endress+Hauser, Inc. Terms and Conditions of Sale for shipping, tax, and payment terms. Complete product information: www.e-direct.us/ftl20h Electrical connection DC-PNP with M12 × 1 connector DC-PNP with valve connector AC two-wire with valve connector AS-i with M12 × 1 connector 12 4 AS-i + 1: BN 3: BU AS-i – 3 12 43 R L– L+ 0,5 A 1: BN 3: BU 4: BK 12 43 R L– L+ 0,5 A 1: BN 2: WT 3: BU 1 2 + – 3 R L–PE L+ 0,5 A 1 2 + – 3 R L–PE L+ 0,5 A 1 >19 V 3 R L1PE N 0,5 A 1 >19 V 2 R L1PE N 0,5 A Max. Min. Temperature switch Thermophant T TTR35 Compact thermometer Easytemp TMR35 Pressure transmitter Cerabar T PMP135
  • 5. Application / FunctionOverview Technical data Dimensions Electrical connection Price table Contact Go to shop Contact E-direct Endress+Hauser, Inc. 2350 Endress Place Greenwood, IN 46143 Direct order Internet www.e-direct.us by phone 888-EH-DIRECT (343-4732) per Fax 317-535-8498 E-Mail e-direct@us.endress.com