7SR45 Self Powered Overcurrent Protection Relay
Description
• The 7SR45 Argus Self Powered/Dual Powered NonDirectional Overcurrent and
Earth Fault Relay is developed using the latest generation of hardware technology
and is available in multiple variants depending on the Current Transformer (CT),
binary input/binary output, power supply, and communication configuration. 7SR45
is a member of Siemens Reyrolle® protection devices Argus product family.
• The 7SR45 Argus Self Powered/Dual Powered NonDirectional Overcurrent and
Earth Fault Relay is housed either in a 4U high, size 4 or height reduced non draw-
out case and provides protection, monitoring, instrumentation, and metering with
integrated input and output logic and fault reports.
• The relay functionality can be configured via a front USB port for local PC
connection or rear electrical RS485 (optional) port for remote connection. By
using the Reydisp Evolution software, the user can update the settings and view
the fault records (trip log) and the event records (event log).
• 7SR45 Argus Self Powered/Dual Powered Non-Directional Overcurrent and Earth
Fault Relay supports the IEC 60870-5-103 and Modbus communication protocols.
• 7SR45 Argus Self Powered/Dual Powered Non-Directional Overcurrent and Earth
Fault Relay can indicate the trip with local and remote flag indicator
Data Storage and Communication
• Front USB port + Rear RS485 port (optional)
• Protocols – IEC 60870-5-103, Modbus RTU
• Fault Records (Trip Log)
• Event Records (Event Log)
• Time Synchronism
• Viewing and Changing Settings
• Battery Profiling
MonitoringFunctions
• Primary/Secondary Current Phases and Earth
• Binary Input/Binary Output Status
• Time and Date
• Fault Records (Trip Log)
• Event Records (Event Log)
User Interface
• 16 Character x 2 Line Backlit LCD
• Menu Navigation Keys
• 9 non-programmable LEDs
• Local Flag Indicator
Application
o 7SR45 Argus Self Powered/Dual Powered Relay is a numerical overcurrent and
earth fault protection relay primarily intended for secondary distribution electrical
networks.
o The 7SR45 Argus Self Powered/Dual Powered NonDirectional Overcurrent and
Earth Fault Relay is designed to operate with/without an auxiliary supply.The 7SR45
Dual Powered Non-Directional Overcurrent and Earth Fault relay is powered
primarily from the auxiliary voltage even though all other power sources are
available.
o In the absence of auxiliary voltage, the relay is powered by CT input.
o The relay offers definite-time and inverse-time overcurrent and earth fault
protection functions in accordance to IEC and ANSI standards.
o 7SR45 Argus Self Powered/Dual Powered Non-Directional Overcurrent and Earth
Fault Relay are built in with a capacitor discharge pulse output for low-energy trip
coil of the circuit breaker. Changeover binary outputs are also available for trip via
an auxiliary powered shunt trip coil
o 7SR45 Argus Self Powered/Dual Powered Non-Directional Overcurrent and Earth
Fault Relay are targeted for the following applications:
• Protection Relay for Ring Main Units (RMU)
• Back up protection relay for the medium voltage applications
• Protection applications in remote locations where auxiliary supply is not available
Functional Diagram
50/51 Phase Overcurrent Fault 50 INST/DTL and 51 IDMTL/DTL elements provide
overcurrent protection, each with independent settings for pickup current, time-
multiplier (51), and time-delays. User can select IEC or ANSI time current
characteristics.
50G/51G/ 50N/51N Measured/Derived Earth Fault Two earth fault measurement
modes are available. One mode directly measures the earth current from an
independent CT (50G/51G) and the second mode derives the residual current
internally from the 3 line CTs (50N/51N).
The IDMT curve
has a user
programmable
reset
characteristic
either DTL or IEC
or ANSI decaying
to improve
grading with
electromechanical
protection.
Communications
• The relay offers a USB port as a standard on the front of all units.All of the relay
functions can be set on a PC using Reydisp Evolution software via the USB port.The
connection is made with a USB cable and operates with a ‘plug and play’ connection,
so no pre-setting of the relay is required.
• In the dual powered relays, the front port can be switched off or set to use either
the Modbus RTU or IEC 60870-5-103 protocols for testing purposes. IEC60870-5-
103 protocol is a default in the Self Powered Relays.
NOTE: Reydisp Evolution software will work with the relay only when the USB port is
configured to the IEC 60870-5-103 protocol in the dual powered relays.
An internal terminating resistor is provided, which can be connected into the circuit
by adding a wire loop between the relevant terminals.
Data Acquisition -Via Communication Interface
Sequence of Event Records (Event Log)
Up to 100 events can be stored and time tagged to 1 ms resolution.The events are
stored on first-in-first-out basis.The events are available through the communication
interface.
Fault Records (Trip Log)
The last 10 fault records are displayed on the relay fascia and are also available
through the communication interface with time and date of trip, measured quantities,
and type of fault.
RealTime Clock
The time and date can be set and is maintained while the relay is de-energised by a
coin cell battery
Construction
• The relay is housed in a non draw-out 4U high, size 4 case
• The rear connection comprises of user friendly pluggable type terminals for pulse
and flag output, binary inputs , binary outputs, RS485 communication and
auxiliary input.
• The CT terminals are suitable for ring type lug connection to provide a secure
and reliable termination.
User Interface
The operator interface is designed to
provide a user friendly method of viewing
menus, entering settings, and retrieving data
from the relay. Five buttons are provided
for navigation around the menu structure.
Additionally, two buttons are provided for
battery ON/OFF and backlight ON/OFF
functionality.
LCD
A 2 line by 16 character liquid crystal display with power save operation indicates the
relay identifier, settings, instrumentation, and fault data.
LEDs
9 non-programmable LEDs are available eliminating the need for expensive panel
mounted pilot lights and associated wiring.
Flag Indicator
1 local flag indicator is provided and configured for the trip indication.
Relay Information
The user can also give the device its own identity by editing the ‘Relay Identifier’
displayed on the LCD
Case Dimensions
Terminal/Wiring Diagram
Function Overview
Protection
• 50 Instantaneous Overcurrent Protection
• 50N/G Instantaneous Derived/Measured Earth Fault Protection
• 51 Time Delayed Overcurrent Protection
• 51N/G Time Delayed Derived/Measured Earth Fault Protection
• 50LC/SOTF Switch-On-To-Fault
Features
• Password Protection
• Self Monitoring
• Trip Timers
• Healthy shut-down below operating ranges
• Remote reset (binary input based) of flag with/without
• CT power and Auxiliary power
• Two Settings Groups
Mob No:
Mr. Piyush Rathi- +91-9819614841
Website:
www.reliservsolution.com
Email-ID:
piyush@reliserv.in
sales1@reliserv.in
Address:
Office No: 9, Space Heights,
Plot No. 53/54 , Sector 34,
Kamothe,Navi Mumbai- 410209
Contact us

More Related Content

PDF
7SR157 Synchronising Protective Relay
PDF
7SR158 Argus Relay
PDF
7SR110 Argus Relay
PDF
American Fibertek MTX-91685C-SL User Manual
PDF
7SR242 Transformer Protection Relay
PDF
7SJ81 Overcurrent Relay
PDF
American Fibertek RR944C User Manual
PPTX
AUTOMATIC WIRELESS POWER GRID CONTROL
7SR157 Synchronising Protective Relay
7SR158 Argus Relay
7SR110 Argus Relay
American Fibertek MTX-91685C-SL User Manual
7SR242 Transformer Protection Relay
7SJ81 Overcurrent Relay
American Fibertek RR944C User Manual
AUTOMATIC WIRELESS POWER GRID CONTROL

What's hot (20)

PDF
7SC80 Feeder Automation Controller
PDF
7SR210 Overcurrent Relay
PDF
American Fibertek MT926C User Manual
DOCX
Study of Data sheet of 56824 DSP processors
PDF
American Fibertek MRX8685CSL User Manual
PPTX
Tunnel robot ppt
PDF
American Fibertek MRX8685C User Manual
PPTX
Remote Operated Spy Robot Circuit
PDF
American Fibertek MRM14852F8 User Manual
PDF
American Fibertek MRX8885C User Manual
PDF
QuickSilver Controls QCI-DS018 QCI-D2-IG8
PPTX
Remote Control Circuit.
PDF
Edwards Signaling SA-CLA Data Sheet
PPTX
TV Remote Operated Domestic Appliances Control
PPT
Interfacing methods of microcontroller
PPT
Intelligent detectors
PPTX
Medicine reminder
PDF
LayerZero Series 70 ePODs: Dual Type-P
PPTX
RF Based Home Automation System
PDF
Wireless Radio Frequency Module Using PIC Microcontroller.
7SC80 Feeder Automation Controller
7SR210 Overcurrent Relay
American Fibertek MT926C User Manual
Study of Data sheet of 56824 DSP processors
American Fibertek MRX8685CSL User Manual
Tunnel robot ppt
American Fibertek MRX8685C User Manual
Remote Operated Spy Robot Circuit
American Fibertek MRM14852F8 User Manual
American Fibertek MRX8885C User Manual
QuickSilver Controls QCI-DS018 QCI-D2-IG8
Remote Control Circuit.
Edwards Signaling SA-CLA Data Sheet
TV Remote Operated Domestic Appliances Control
Interfacing methods of microcontroller
Intelligent detectors
Medicine reminder
LayerZero Series 70 ePODs: Dual Type-P
RF Based Home Automation System
Wireless Radio Frequency Module Using PIC Microcontroller.
Ad

Similar to 7SR45 Self Powered Overcurrent Protection Relay (20)

PDF
7SR12 Directional Over Current Relay
PDF
7SR105 Motor Protection Relay
PPTX
7SR10 Overcurrent Relay
PDF
7SR18 Solkor Protection Relay
PDF
7SR11 Overcurrent Relay
PDF
7SR220 Overcurrent Relay
PDF
7SR120 Argus Relay
PDF
Rej603 pg 1_mdb07217-yn_e_ne
PDF
7SR191 Capa Protection Relays
PDF
7SR224 Overcurrent Protection Relay
PDF
7UT613 Differential Protection Relay For Three Winding
PDF
7SA61 Distance Protection Relay For All Voltage Levels
PDF
7SR23 High Impedance Bus Bar Protection Relay
PDF
7SR17 Motor Protection Relay
PDF
7SJ61 Over Current Relay
PDF
7SJ80 Overcurrent Relay
PPTX
Numerical-Relay-PPT-1-convvffverted.pptx
PDF
Novatek Electro India presentation
PPTX
Static_relay_sgp_............................
PPTX
Protection presentation
7SR12 Directional Over Current Relay
7SR105 Motor Protection Relay
7SR10 Overcurrent Relay
7SR18 Solkor Protection Relay
7SR11 Overcurrent Relay
7SR220 Overcurrent Relay
7SR120 Argus Relay
Rej603 pg 1_mdb07217-yn_e_ne
7SR191 Capa Protection Relays
7SR224 Overcurrent Protection Relay
7UT613 Differential Protection Relay For Three Winding
7SA61 Distance Protection Relay For All Voltage Levels
7SR23 High Impedance Bus Bar Protection Relay
7SR17 Motor Protection Relay
7SJ61 Over Current Relay
7SJ80 Overcurrent Relay
Numerical-Relay-PPT-1-convvffverted.pptx
Novatek Electro India presentation
Static_relay_sgp_............................
Protection presentation
Ad

More from ashwini reliserv (20)

PDF
Auxiliary relay 7PJ12, 7PJ113, 7PJ11, 7PJ15
PDF
SICAM FSI – Fault Sensor Indicator
PDF
SICAM FCG-Fault Collector Gateway
PDF
SICAM FPI - Fault Passage Indicator
PDF
SICAM FCM – Feeder Condition Monitor
PDF
Small Control Center System SICAM 230
PDF
SICAM Diamond (6MD552)
PDF
SICAM Disto substation automation
PDF
SICAM PQ Analyzer
PDF
SICAM SCC (6MD55) automation
PDF
SICAM AK 3 automation
PDF
SICAM PAS Software (6MD90)
PDF
RUGGEDCOM RSL910 vdsl modems
PDF
RUGGEDCOM SFPs accessories
PDF
RUGGEDCOM RPS1300 accessories
PDF
RUGGEDCOM REFLEX software
PDF
RUGGEDCOM ELAN software
PDF
RUGGEDCOM RP110 Ethernet injectors
PDF
RUGGEDCOM RP100 Ethernet injectors
PDF
RUGGEDCOM RS910W wireless lan
Auxiliary relay 7PJ12, 7PJ113, 7PJ11, 7PJ15
SICAM FSI – Fault Sensor Indicator
SICAM FCG-Fault Collector Gateway
SICAM FPI - Fault Passage Indicator
SICAM FCM – Feeder Condition Monitor
Small Control Center System SICAM 230
SICAM Diamond (6MD552)
SICAM Disto substation automation
SICAM PQ Analyzer
SICAM SCC (6MD55) automation
SICAM AK 3 automation
SICAM PAS Software (6MD90)
RUGGEDCOM RSL910 vdsl modems
RUGGEDCOM SFPs accessories
RUGGEDCOM RPS1300 accessories
RUGGEDCOM REFLEX software
RUGGEDCOM ELAN software
RUGGEDCOM RP110 Ethernet injectors
RUGGEDCOM RP100 Ethernet injectors
RUGGEDCOM RS910W wireless lan

Recently uploaded (20)

PDF
Digital Marketing Course in North Delhi – Complete Guide.pdf
PDF
Dean, Jodi: Concept Paper, Park at Stable Acres.pdf
PDF
The Essential Role of Gutter Guard Mesh in Safeguarding Your Property
PPTX
Moving House Why Removals in Melbourne Make It Easy.pptx
PDF
Engine Volvo EC200B Excavator Repair Manual.pdf
PPTX
CCC-Ancillary-Slidesk powerpoint present.pptx
PPTX
How to Choose the Right Moving Boxes for Your Next Move .pptx
PDF
Income Tax Return Filing (ITR Filing) by Sharkbite Legal
PDF
Best IPTV Reseller Program & Best IPTV Reseller Panel 2025
PPTX
Your Trusted SEO Company in San Antonio – Studio0413
PDF
Maryland Window Replacement | Green Energy LLC Excellence
PPTX
Understanding Time of Supply of Services Under GST A Key Concept for Tax Comp...
PPTX
Miscellaneous Steel Detailing Services Siliconec.pptx
PDF
data_center_optimization_playbook_v4_239872_0 (1).pdf
PDF
From Concept to Completion Premium Kitchen Design and Installation Solutions ...
PDF
The Future of Transport and Logistics in Southeast Asia.pdf
PDF
catalogo de peças da Dominar-400 PEÇAS.pdf
PPTX
Courier-Delivery-App-Development-Unlocking-the-Future-of-Logistics.pptx
PDF
Wearable Devices App Development Company.pdf
PDF
SAMPA Presenttaion 19 September 2018.pdf
Digital Marketing Course in North Delhi – Complete Guide.pdf
Dean, Jodi: Concept Paper, Park at Stable Acres.pdf
The Essential Role of Gutter Guard Mesh in Safeguarding Your Property
Moving House Why Removals in Melbourne Make It Easy.pptx
Engine Volvo EC200B Excavator Repair Manual.pdf
CCC-Ancillary-Slidesk powerpoint present.pptx
How to Choose the Right Moving Boxes for Your Next Move .pptx
Income Tax Return Filing (ITR Filing) by Sharkbite Legal
Best IPTV Reseller Program & Best IPTV Reseller Panel 2025
Your Trusted SEO Company in San Antonio – Studio0413
Maryland Window Replacement | Green Energy LLC Excellence
Understanding Time of Supply of Services Under GST A Key Concept for Tax Comp...
Miscellaneous Steel Detailing Services Siliconec.pptx
data_center_optimization_playbook_v4_239872_0 (1).pdf
From Concept to Completion Premium Kitchen Design and Installation Solutions ...
The Future of Transport and Logistics in Southeast Asia.pdf
catalogo de peças da Dominar-400 PEÇAS.pdf
Courier-Delivery-App-Development-Unlocking-the-Future-of-Logistics.pptx
Wearable Devices App Development Company.pdf
SAMPA Presenttaion 19 September 2018.pdf

7SR45 Self Powered Overcurrent Protection Relay

  • 2. Description • The 7SR45 Argus Self Powered/Dual Powered NonDirectional Overcurrent and Earth Fault Relay is developed using the latest generation of hardware technology and is available in multiple variants depending on the Current Transformer (CT), binary input/binary output, power supply, and communication configuration. 7SR45 is a member of Siemens Reyrolle® protection devices Argus product family. • The 7SR45 Argus Self Powered/Dual Powered NonDirectional Overcurrent and Earth Fault Relay is housed either in a 4U high, size 4 or height reduced non draw- out case and provides protection, monitoring, instrumentation, and metering with integrated input and output logic and fault reports. • The relay functionality can be configured via a front USB port for local PC connection or rear electrical RS485 (optional) port for remote connection. By using the Reydisp Evolution software, the user can update the settings and view the fault records (trip log) and the event records (event log). • 7SR45 Argus Self Powered/Dual Powered Non-Directional Overcurrent and Earth Fault Relay supports the IEC 60870-5-103 and Modbus communication protocols. • 7SR45 Argus Self Powered/Dual Powered Non-Directional Overcurrent and Earth Fault Relay can indicate the trip with local and remote flag indicator
  • 3. Data Storage and Communication • Front USB port + Rear RS485 port (optional) • Protocols – IEC 60870-5-103, Modbus RTU • Fault Records (Trip Log) • Event Records (Event Log) • Time Synchronism • Viewing and Changing Settings • Battery Profiling MonitoringFunctions • Primary/Secondary Current Phases and Earth • Binary Input/Binary Output Status • Time and Date • Fault Records (Trip Log) • Event Records (Event Log) User Interface • 16 Character x 2 Line Backlit LCD • Menu Navigation Keys • 9 non-programmable LEDs • Local Flag Indicator
  • 4. Application o 7SR45 Argus Self Powered/Dual Powered Relay is a numerical overcurrent and earth fault protection relay primarily intended for secondary distribution electrical networks. o The 7SR45 Argus Self Powered/Dual Powered NonDirectional Overcurrent and Earth Fault Relay is designed to operate with/without an auxiliary supply.The 7SR45 Dual Powered Non-Directional Overcurrent and Earth Fault relay is powered primarily from the auxiliary voltage even though all other power sources are available. o In the absence of auxiliary voltage, the relay is powered by CT input. o The relay offers definite-time and inverse-time overcurrent and earth fault protection functions in accordance to IEC and ANSI standards. o 7SR45 Argus Self Powered/Dual Powered Non-Directional Overcurrent and Earth Fault Relay are built in with a capacitor discharge pulse output for low-energy trip coil of the circuit breaker. Changeover binary outputs are also available for trip via an auxiliary powered shunt trip coil o 7SR45 Argus Self Powered/Dual Powered Non-Directional Overcurrent and Earth Fault Relay are targeted for the following applications: • Protection Relay for Ring Main Units (RMU) • Back up protection relay for the medium voltage applications • Protection applications in remote locations where auxiliary supply is not available
  • 5. Functional Diagram 50/51 Phase Overcurrent Fault 50 INST/DTL and 51 IDMTL/DTL elements provide overcurrent protection, each with independent settings for pickup current, time- multiplier (51), and time-delays. User can select IEC or ANSI time current characteristics. 50G/51G/ 50N/51N Measured/Derived Earth Fault Two earth fault measurement modes are available. One mode directly measures the earth current from an independent CT (50G/51G) and the second mode derives the residual current internally from the 3 line CTs (50N/51N). The IDMT curve has a user programmable reset characteristic either DTL or IEC or ANSI decaying to improve grading with electromechanical protection.
  • 6. Communications • The relay offers a USB port as a standard on the front of all units.All of the relay functions can be set on a PC using Reydisp Evolution software via the USB port.The connection is made with a USB cable and operates with a ‘plug and play’ connection, so no pre-setting of the relay is required. • In the dual powered relays, the front port can be switched off or set to use either the Modbus RTU or IEC 60870-5-103 protocols for testing purposes. IEC60870-5- 103 protocol is a default in the Self Powered Relays. NOTE: Reydisp Evolution software will work with the relay only when the USB port is configured to the IEC 60870-5-103 protocol in the dual powered relays. An internal terminating resistor is provided, which can be connected into the circuit by adding a wire loop between the relevant terminals.
  • 7. Data Acquisition -Via Communication Interface Sequence of Event Records (Event Log) Up to 100 events can be stored and time tagged to 1 ms resolution.The events are stored on first-in-first-out basis.The events are available through the communication interface. Fault Records (Trip Log) The last 10 fault records are displayed on the relay fascia and are also available through the communication interface with time and date of trip, measured quantities, and type of fault. RealTime Clock The time and date can be set and is maintained while the relay is de-energised by a coin cell battery
  • 8. Construction • The relay is housed in a non draw-out 4U high, size 4 case • The rear connection comprises of user friendly pluggable type terminals for pulse and flag output, binary inputs , binary outputs, RS485 communication and auxiliary input. • The CT terminals are suitable for ring type lug connection to provide a secure and reliable termination.
  • 9. User Interface The operator interface is designed to provide a user friendly method of viewing menus, entering settings, and retrieving data from the relay. Five buttons are provided for navigation around the menu structure. Additionally, two buttons are provided for battery ON/OFF and backlight ON/OFF functionality. LCD A 2 line by 16 character liquid crystal display with power save operation indicates the relay identifier, settings, instrumentation, and fault data. LEDs 9 non-programmable LEDs are available eliminating the need for expensive panel mounted pilot lights and associated wiring. Flag Indicator 1 local flag indicator is provided and configured for the trip indication. Relay Information The user can also give the device its own identity by editing the ‘Relay Identifier’ displayed on the LCD
  • 12. Function Overview Protection • 50 Instantaneous Overcurrent Protection • 50N/G Instantaneous Derived/Measured Earth Fault Protection • 51 Time Delayed Overcurrent Protection • 51N/G Time Delayed Derived/Measured Earth Fault Protection • 50LC/SOTF Switch-On-To-Fault Features • Password Protection • Self Monitoring • Trip Timers • Healthy shut-down below operating ranges • Remote reset (binary input based) of flag with/without • CT power and Auxiliary power • Two Settings Groups
  • 13. Mob No: Mr. Piyush Rathi- +91-9819614841 Website: www.reliservsolution.com Email-ID: piyush@reliserv.in sales1@reliserv.in Address: Office No: 9, Space Heights, Plot No. 53/54 , Sector 34, Kamothe,Navi Mumbai- 410209 Contact us