SlideShare a Scribd company logo
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 
_______________________________________________________________________________________ 
Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 6 
A FUZZY LOGIC CONTROLLED DC-DC CONVERTER FOR AN 
ELECTROLYZER APPLICATION WITH A VOLTAGE DOUBLER 
K.Shanthi1, U. Rajesh2, A. Mallikarjuna Prasad3 
1EEE Department, St John’s College of Engineering and Technology, Yemmiganur, India 
2EEE Department, St John’s College of Engineering and Technology, Yemmiganur, India 
3EEE Department, St John’s College of Engineering and Technology, Yemmiganur, India 
Abstract 
This paper develops a fuzzy logic controlled dc-dc converter for an electrolyzer application with a voltage doubler. In general day 
by day usage of power is increasing rapidly but the available resources are exhausting in the near future. Hence we are going for 
the renewable energy system (RES). It converts the energy into heat or electricity. Electrolyzer is a part of a renewable energy 
system which converters source power available into hydrogen for fuel cell. But electrolyzer lacks the ability to control the power 
over rapid changes in input and load , hence a power conditioning system is required to connect the electrolyzer to a system dc bus 
. Usually a dc-dc converter is used in the most of application .This project deals with the comparison of three soft switched dc-dc 
converter configurations for an electrolyzer and design of two stage (ZVT boost followed by LCL series resonant converter) with 
fuzzy logic control. The proposed model has a Zero Voltage switching(ZVS) technique which maintain the soft switching for 
complete load range. This proposed model is developed and analyzed using MATLAB/Simulink Software and the simulation results 
obtained justify the accuracy of proposed control technique. 
Keywords: DC-DC converter, electrolyzer, fuzzy logic controller PI controller, SRC, ZVS, ZVT. 
---------------------------------------------------------------------***----------------------------------------------------------------- 
1. INTRODUCTION 
The main drawback of the electrical system is storage .RES 
in the form of hydrogen storage overcome the weakness of 
battery based system. Hence an electrolyzer is needed to 
convert the electricity into hydrogen. The ability to store 
energy at times when the supply exceeds demands will be a 
key to the effective utilization of renewable energy. Because 
many renewable sources (e.g. wind, solar, tidal) are 
intermittent in nature, storage is useful. The figure 1 shows 
the schematic diagram of a RES. 
The basic idea is to keep harvesting the energy resource at a 
steady rate, regardless of the demand. Usually, this results in 
the most efficient operation. If the demand is less than full 
capacity, the excess is diverted into storage medium. in the 
proposed we go for a hydrogen storage which utilizes excess 
electric power to produce hydrogen and oxygen from water 
by means of electrolysis. Energy can be retrieved by running 
them back through a fuel cell. 
Fig. 1 schematic of a renewable energy system 
In this paper we develops a MATLAB/simulink model of 
three soft-switched high-frequency transformer isolated dc-to- 
dc converter configurations for electrolyzer. Firstly, we 
compared the three switching configurations of a dc-dc 
converter. Among them it is shown that LCL type series 
resonant converter with capacitive output filter is suitable 
for this application. Due to the wide variation in input 
voltage and load current, no converter can maintain zero-voltage 
switching (ZVS) for the complete operating range. 
Therefore, a two-stage converter (ZVT boost converter 
followed by LCL SRC with capacitive output filter) is 
adapted. later a PI and FUZZY logic control was 
implemented for a closed loop operation and simulation 
results are compared. 
2. NEED OF A DC-DC CONVERTER 
To achieve proper voltage matching the main components of 
the system should be connected to the DC-bus of RES via dc-dc 
converter. The electrolyzer is interfaced by help of a step-down 
DC/DC converter, while the fuel cell is connected by 
help of a step-up DC/DC converter. 
In principle, any basic power converter topology can be used 
to design a power interface for a fuel cell and an electrolyzer. 
Typically, these converters have a high-frequency voltage 
transformer, which could also perform the function of 
isolation. The main technology development trend here is to 
reduce the power losses in the interface converters in order to 
obtain the highest possible energy efficiency .The following 
figure2 shows the need of a DC-DC converter.
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 
_______________________________________________________________________________________ 
Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 7 
Fig 2 Energy exchange using dc-dc converter 
3. POSSIBLE SOFT SWITCHING 
CONFIGARATIONS FOR THE ELECTROLYZER 
APPLICATION 
Soft switching converters has many advantages over hard 
switching converters .these soft switching converters had a 
advantage of reduce voltage/current stress, reduce EMI, 
reduced switching losses, and allow a greater high frequency 
in high power applications. There are three major types of HF 
transformer isolated soft switching converter configurations 
possible: 1) voltage fed resonant converters 2) current fed 
resonant converters and 3) fixed-frequency resonant transition 
zero-voltage switching (ZVS) pulse width modulation (PWM) 
bridge converters .but current fed resonant converters require 
HF switches rated at 5–6 times the input voltage which 
reduces the efficiency. Hence Voltage fed resonant converter 
with fixed-frequency operation is adopted in this paper. the 
six soft-switching converter configurations for the electrolyzer 
application: 
1) Fixed-frequency series resonant converter (SRC). 
2) Fixed-frequency parallel resonant converter (PRC.) 
3) Fixed-frequency series-parallel or LCC-type resonant 
converter (SPRC). 
4) Fixed-frequency LCL SRC with a capacitive output filter. 
5) Fixed-frequency LCL SRC with an inductive output filter. 
6) Fixed-frequency phase-shifted ZVS PWM full-bridge 
converter. 
Among the aforementioned six converter configurations, the 
SRC and SPRC can operate with the ZVS, only for very 
narrow variations in supply and load variations in the present 
application. In the case of PRC, the inverter peak current does 
not decrease much with reduction in the load current and there 
is no coupling capacitor in series with the HF transformer. 
Therefore, the first three configurations are not considered. 
Table: 1 Comparison of Converters 
Problems LCL SRC 
with cap 
filter 
LCL SRC 
with 
inductive 
filter 
Phase 
shifted 
PWM 
converter 
ZVS range 100%load 
to 10%load 
minimum 
input 
voltage 
100%load 
to 10%load 
minimum 
input 
voltage 
100%load 
to 10%load 
minimum 
input 
voltage 
Duty cycle 
loss 
Not present Present Present 
Rectifier 
ringing 
Not present Present, 
requires 
snubber 
Present, 
requires 
snubber 
4. BLOCK DIAGRAM OF A EXISTED SYSTEMS 
The following figure3 shows the block diagram of a existed 
system. it consists renewable source input which was given 
to ZVT boost converter from there it is converted into a high 
frequency AC using LCL- SRC converter and its output was 
coupled to a rectifier using HF step down transformer. The 
DC output of the rectifier is used to feed the electrolyzer 
plant 
Fig 3 Block diagram of a existed system 
5. BLOCK DIAGRAM OF PROPOSED SYSTEM 
In this proposed system a voltage doubler is placed instead of 
rectifier, as it performs the rectification and as well as 
doubles the output voltage . 
Vo = 2* Vout 
Even though existing two stage boost converter system is 
operating accurately ,for a wide changing load and input 
sources time to time there is fluctuations in the output .The 
following figure 4 shows the block diagram of a proposed 
system.
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 
_______________________________________________________________________________________ 
Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 8 
Fig 4 Block Diagram of A Proposed System 
6. RESULTS AND DISCUSSIONS 
MATLAB is a software package for computation in 
engineering, science, and applied mathematics. It offers a 
powerful programming language, excellent graphics, and a 
wide range of expert knowledge. MATLAB is published by 
and a trademark of The MathWorks, Inc. 
6.1 MATLAB Model for a LCL-SRC with Inductive 
Filter 
The following figure5 shows the MATLAB model of a LCL-SRC 
with an inductive output filter. And the figures 6, 7, 8 
shows the input voltage ,voltage across Vab , output voltage 
Vo .Their values are given as follows 
Input voltage = 40V 
Voltage across Vab = 40 V 
Output voltage Vo = 54 
Fig. 5. MATLAB model of a lcl-src with an inductive filter 
0 2 4 6 8 10 12 14 
x 10 
4 
-10 
0 
10 
20 
30 
40 
50 
60 
time 
output voltage 
Fig. 6. simulation result showing the output voltage Vo 
9500 9600 9700 9800 9900 10000 10100 10200 10300 10400 10500 
-50 
-40 
-30 
-20 
-10 
0 
10 
20 
30 
40 
50 
time 
voltage at vab 
Fig. 7. Simulation result showing voltage vab 
2.06 2.07 2.08 2.09 2.1 2.11 2.12 2.13 
x 10 
4 
-400 
-300 
-200 
-100 
0 
100 
200 
300 
400 
Fig. 8. Simulation result showing inductor current il 
6.2 MATLAB Model for a Fixed-Frequency Phase- 
Shifted ZVS PWM Full-Bridge Converter 
The following figure 9 shows the MATLAB model of a 
LCL-SRC with an inductive output filter. . And the figures 
10, 11, 12 shows the input voltage ,voltage across Vab , output 
voltage Vo .Their values are given as follows 
Input voltage = 40V 
Voltage across Vab = 40 V 
Output voltage Vo = 54 V 
Fig 9 MATLAB model of a fixed-frequency phase-shifted 
ZVS PWM full-bridge converter 
0 2 4 6 8 10 12 
x 10 
4 
0 
5 
10 
15 
20 
25 
30 
35 
40 
time 
output voltage 
Fig. 10. simulation result showing the output voltage Vo
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 
_______________________________________________________________________________________ 
Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 9 
6 6.05 6.1 6.15 6.2 6.25 6.3 
x 10 
4 
-50 
-40 
-30 
-20 
-10 
0 
10 
20 
30 
40 
50 
Fig. 11. Simulation result showing voltage vab 
3450 3500 3550 3600 3650 3700 3750 3800 3850 3900 
-40 
-20 
0 
20 
40 
60 
80 
time 
inductor current 
Fig. 12. Simulation result showing inductor current il 
6.3 MATLAB Model for a LCL-SRC with 
Capacitive Output Filter 
The following figure 13 shows the MATLAB model of a 
LCL-SRC with a capacitive output filter. And the figures 14, 
15, 16 shows the input voltage ,voltage across Vab , output 
voltage Vo .Their values are given as follows 
Input voltage = 40V 
Voltage across Vab = 40 V 
Output voltage Vo = 54 V 
Fig. 13. MATLAB model of a LCL-SRC with a capacitive 
output filter 
0 2 4 6 8 10 12 
x 10 
4 
-20 
0 
20 
40 
60 
time 
output voltage 
Fig. 14. simulation result showing the output voltage Vo 
1.18 1.2 1.22 1.24 1.26 1.28 1.3 1.32 1.34 
x 10 
4 
-6 
-4 
-2 
0 
2 
4 
6 
time 
voltage at vab 
Fig. 15. Simulation result showing voltage vab 
2250 2300 2350 2400 2450 2500 2550 2600 2650 2700 2750 
-250 
-200 
-150 
-100 
-50 
0 
50 
100 
150 
200 
time 
voltage at vab 
Fig. 16. Simulation result showing inductor current 
From the figures 6,10 and 14 it can be say that LCL-SRC 
with capacitive output filter has a better performance as the 
peak in the output voltage had reduced to a great extent. and 
also it maintains the ZVS for changes . 
6.4 MATLAB Model for a Two Stage (ZVT Boost 
LCL-SRC) Approach 
LCL SRC with capacitive output filter has better 
performance compared to other configuration, it maintains 
ZVS for wide change in input voltage. But for wide change 
in input an extra resonant inductor is required. So a ZVT 
boost converter is required to boost input. By using this 
converter the complexity in simplifying the resonant 
component can be reduced when compared to other 
approach. 
This approach not only achieves ZVS for all the switches but 
also simplifies the design of Lr and Cs resonant components. 
The following figure 17 shows the MATLAB model of ZVT 
boost LCL-SRC with capacitive output filter. And the figures 
18, 19, 20 shows the input voltage ,voltage across Vab , output 
voltage Vo .Their values are given as follows 
Input voltage = 40V
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 
_______________________________________________________________________________________ 
Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 10 
Voltage across Vab = 40 V 
Output voltage Vo = 60 V 
Fig. 17. MATLAB model of a LCL-SRC with a capacitive 
output filter 
3.25 3.3 3.35 3.4 3.45 3.5 3.55 
x 10 
4 
-150 
-100 
-50 
0 
50 
100 
150 
time 
vab 
Fig. 18. Simulation result showing voltage vab 
2.46 2.48 2.5 2.52 2.54 2.56 2.58 2.6 2.62 2.64 
x 10 
4 
-400 
-300 
-200 
-100 
0 
100 
200 
300 
400 
time 
inductor current 
Fig. 19. Simulation result showing inductor current 
0 0.5 1 1.5 2 2.5 3 
x 10 
5 
0 
20 
40 
60 
80 
100 
120 
140 
160 
180 
200 
time 
output voltage 
Fig. 20. Simulation result showing output voltage Vo 
From the above figure 20 it can observe that smoot output 
voltage is observed .hence by adopting the ZVT boost at the 
input side the input is maintained to a constant value hence 
there by reducing the swithing losses at the inverter 
6.5 MATLAB Model for a PI Controller with 
Voltage Doubler 
The following figure 21 shows the two stage(ZVT boost 
LCL-SRC ) with an voltage doubler and a PI controller. At 
the input side a FUEL cell stack taken as the input source. 
And the figures 23, 24, 25 shows the input voltage ,voltage 
across Vab , output voltage Vo .Their values are given as 
follows 
Input voltage = 40V 
Voltage across Vab = 100 V 
Output voltage Vo = 120V 
Fig. 21. MATLAB model of a pi controller with voltage 
doubler 
Fig. 22. MATLAB model of a subsystem of a PI controller 
2000 4000 6000 8000 10000 12000 14000 16000 18000 
-150 
-100 
-50 
0 
50 
100 
time 
vab 
Fig. 23. Simulation result showing voltage Vab
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 
_______________________________________________________________________________________ 
Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 11 
0 2 4 6 8 10 12 
x 10 
4 
-20 
0 
20 
40 
60 
80 
100 
120 
140 
time 
vo 
Fig. 24. Simulation result showing output voltage Vo 
0 2 4 6 8 10 12 
x 10 
4 
-600 
-400 
-200 
0 
200 
400 
600 
time 
inductor current 
Fig. 26. Simulation result showing inductor current 
6.6 MATLAB Model of a Fuzzy Logic System 
The use of fuzzy logic is attractive for control systems since 
it enables the use of multiple inputs. Fuzzy logic also enables 
the description of the behavior of the controller using several 
rules defined by a set of linguistic variables. Hence, FLC is a 
promising tool for controlling complex, linguistic based 
systems. The steps to implement the fuzzy logic controller is 
1. Create the membership values (fuzzify). 
2. Specify the rule table. 
3. Determine your procedure for defuzzifying the result. 
First we have to fuzzify the data or create membership values 
for the data and put them into fuzzy sets. simply, we have to 
divide each set of data into ranges. 
The following figure 27 shows the two stage(ZVT boost 
LCL-SRC ) with an voltage doubler and a Ffuzzy logic 
controller. At the input side a FUEL cell stack taken as the 
input source. And the figures 29, 30, 31 shows the input 
voltage ,voltage across Vab , output voltage Vo . 
Fig. 27. MATLAB model of a FUZZY controller with 
voltage doubler 
Fig. 28. MATLAB model of a subsystem of a FUZZY 
controller 
Fig. 29. fuzzy surface system 
1000 2000 3000 4000 5000 6000 7000 8000 
-100 
-50 
0 
50 
100 
time 
voltage across ab 
Fig. 30. Simulation result showing voltage Vab 
0 2 4 6 8 10 12 
x 10 
4 
-20 
0 
20 
40 
60 
80 
100 
120 
time 
output voltage vo 
Fig. 31. Simulation result showing voltage Vab
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 
_______________________________________________________________________________________ 
Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 12 
0 2 4 6 8 10 12 
x 10 
4 
-500 
-400 
-300 
-200 
-100 
0 
100 
200 
300 
400 
Fig. 32. Simulation result showing voltage Vab 
In the above figure 27 a fuzzy logic controller was 
implemented with mamdani fuzzy inference type.when 
compared the results of PI and fuzzy controller from the 
figures 24and 30 it can be shown that even low voltage 
application also the fuzzy controller can reduce the output 
distortions.And also it maintains the ZVS for all switches 
reducing the switching losses. 
fuell stack rating = 6KW-45V DC 
no of cells = 65 
voltage at Vab = 100 v 
output voltage = 120 V 
7. CONCLUSIONS 
In this paper a fuzzy logic controlled DC-DC converter for an 
electrolyzer application has been implemented using 
MATLAB/simulink. Among available converter 
configurations it is shown that the a ZVT BOOST along with 
LCL –SRC converter is best one for the electrolyzer. To 
reduce the output distortions a PI controller was kept in order 
to reduce the steady state error. A voltage doubler introduced 
in the circuit acts as both rectifier and as voltage doubler .the 
simulation results are checked for both fuzzy and PI 
controller. It is shown that by using fuzzy logic controlled 
converter the conversion can be operated smoothly and 
efficiently for electrolyzer application compared to the other 
converters. And the output voltage range also doubled . 
REFERENCES 
[1] D. Shapiro, J. Duffy, M. Kimble, and M. Pien, “Solar-powered 
regenerative PEM electrolyzer/fuel cell 
system,” J. Solar Energy, vol. 79, pp. 544–550, 2005. 
[2] X. Zhang, H. S.-H. Chung, X. Ruan, and A. Ioinovici, 
“A ZCS full-bridge converter without voltage 
overstress on the switches,” IEEE Trans. 
PowerElectron., vol. 25, no. 3, pp. 686–698, Mar. 201 
[3] D. S. Gautam and A. K. S. Bhat, “A two-stage soft-switched 
converter for electrolyser application,” in 
Proc. Nat. Power Syst. Conf., Mumbai, India, 2008, 
pp. 524–528. 
[4] A.K.S. Bhat, "Analysis and design of LCL-type 
resonant converter", IEEE Trans. on Industrial 
Electronics, vol. 41, no. 1, pp. 118-124, Feb. 1994. 
[5] A.K.S. Bhat, "Analysis and design of a fixed 
frequency LCL-type series resonant converter," IEEE 
Trans. on Aerospace and Electronic Systems,vol. 31, 
no. 1, Jan. 1995, 125-137. 
[6] Ahmadi, P., Dincer, I., Rosen, M.A., 2013. Energy 
and exergy analyses of hydrogen production via solar-boosted 
ocean thermal energy conversion and PEM 
electrolysis. International Journal of Hydrogen 
Energy, 38 (4) : 1795- 1805. 
[doi:10.1016/j.ijhydene.2012.11.025] 
[7] Arriaga, L.G., Martinez, W., Cano, U., Blud, H., 
2007. Direct coupling of a solar-hydrogen system in 
Mexico. International Journal of Hydrogen Energy, 
32 (13): 2247- 2252. 
[doi:10.1016/j.ijhydene.2006.10.067] 
[8] Y. Jang and M. M. Jovanovic, “A new family of full-bridge 
ZVS converters,” IEEE Trans. Power 
Electron., vol. 19, no. 3, pp. 701–708, May 2004. 
[9] H. Bodur and A. F. Bakan, “A new ZVT-PWM DC-DC 
converter,” IEEE Trans. on Power Electr., vol. 
17, no. 1, Jan. 2002, pp. 40-47. 
[10] R. Streit and D. Tollik, “High efficiency telecom 
rectifier using a novel soft-switched boost based input 
current shaper”, IEEE INTELC Conf. Record, 1991, 
pp.720-726. 
[11] Ferraro, “An overview of low-loss snubber 
technology for transistor converters,” in Proc. IEEE 
Power Electron. Spec. Conf., 1982, pp.466–477. 
[12] G. Hua, C. S. Leu, Y. Jiang, and F. C. Y. Lee, “Novel 
zero-voltagetransition PWM converters,” IEEE Trans. 
Power Electron., vol. 9, pp. 213–219, Mar. 1994. 
601–606, Nov. 1994. 
[13] D. S. Gautam and A. K. S. Bhat, “A two-stage soft-switched 
converter for electrolyser application,” in 
Proc. Nat. Power Syst. Conf., Mumbai, India, 2008, 
pp. 524–528.

More Related Content

PDF
Simulation and Implementation of Quasi-Z-Source Based Single-stage Buck/boost...
PDF
Closed Loop Controlled Solar Cell Powered Embedded EZ-Source Inverter fed Ind...
PDF
Power factor improvement in switched reluctance motor drive using pwm
PDF
A unity power factor bridgeless isolated cuk converter fed brushless dc motor...
PDF
Maximum Boost Control for 7-level Z-source Cascaded H-Bridge Inverter
PDF
A ZVS Interleaved Boost AC/DC Converter Using Super Capacitor Power for Hybri...
PDF
Simulation of Z-Source Inverter for Induction Motor Drive
PDF
Comparison of Multicarrier PWM Techniques for Cascaded H-Bridge Multilevel In...
Simulation and Implementation of Quasi-Z-Source Based Single-stage Buck/boost...
Closed Loop Controlled Solar Cell Powered Embedded EZ-Source Inverter fed Ind...
Power factor improvement in switched reluctance motor drive using pwm
A unity power factor bridgeless isolated cuk converter fed brushless dc motor...
Maximum Boost Control for 7-level Z-source Cascaded H-Bridge Inverter
A ZVS Interleaved Boost AC/DC Converter Using Super Capacitor Power for Hybri...
Simulation of Z-Source Inverter for Induction Motor Drive
Comparison of Multicarrier PWM Techniques for Cascaded H-Bridge Multilevel In...

What's hot (18)

DOCX
PF correction using SEPIC
PDF
IRJET- Design and Analysis of Single Phase Modified Quasi-Z-Source Cascaded H...
PDF
A Novel Three Phase Multilevel Inverter with Single DC Link for Induction Mot...
PDF
Single Phase Matrix Converter for Input Power Factor Improvement
PDF
Bi directional dc to dc converters for fuel cell systems
PDF
Performance Investigation of a Monopolar HVDC Transmission System Feeding a ...
PDF
Power Factor Correction with Current Controlled Buck Converter for BLDC Motor...
PDF
A New Multilevel Inverter Structure For High-Power Applications using Multi-c...
PDF
IRJET - Comparative Study of Different AC-DC Converter for High Step Down
PDF
Application of single phase matrix converter topology to an uninterruptible p...
PDF
Buck-Boost Control of Four Quadrant Chopper using Symmetrical Impedance Netwo...
PPTX
Presentation on Z- Source Converter
PDF
I41045662
PDF
Design and Control of Switched-Inductor Quasi-Z-Source Inverter for Photovolt...
PDF
DESIGN OF A MULTIFUNCTIONAL FLYBACK DC-DC CONVERTER WITH CURRENT CONTROL
PDF
Bridgeless pfc modified sepic rectifier with extended gain for universal inpu...
PDF
6.[36 45]seven level modified cascaded inverter for induction motor drive app...
PDF
Mitigation of harmonics using thyristor based 12 pulse voltage source pwm rec...
PF correction using SEPIC
IRJET- Design and Analysis of Single Phase Modified Quasi-Z-Source Cascaded H...
A Novel Three Phase Multilevel Inverter with Single DC Link for Induction Mot...
Single Phase Matrix Converter for Input Power Factor Improvement
Bi directional dc to dc converters for fuel cell systems
Performance Investigation of a Monopolar HVDC Transmission System Feeding a ...
Power Factor Correction with Current Controlled Buck Converter for BLDC Motor...
A New Multilevel Inverter Structure For High-Power Applications using Multi-c...
IRJET - Comparative Study of Different AC-DC Converter for High Step Down
Application of single phase matrix converter topology to an uninterruptible p...
Buck-Boost Control of Four Quadrant Chopper using Symmetrical Impedance Netwo...
Presentation on Z- Source Converter
I41045662
Design and Control of Switched-Inductor Quasi-Z-Source Inverter for Photovolt...
DESIGN OF A MULTIFUNCTIONAL FLYBACK DC-DC CONVERTER WITH CURRENT CONTROL
Bridgeless pfc modified sepic rectifier with extended gain for universal inpu...
6.[36 45]seven level modified cascaded inverter for induction motor drive app...
Mitigation of harmonics using thyristor based 12 pulse voltage source pwm rec...
Ad

Viewers also liked (20)

PDF
Real time implementation of object tracking through
PDF
Detection andprevention of fake access point using sensor nodes
PDF
A new approach to minimize stability factor of an amplifier
PDF
Status of noise in yeshwanthpur circle (bangalore north) based on on site dat...
PDF
Comparative study of various supervisedclassification methodsforanalysing def...
PDF
Sequences classification based on group technology
PDF
Comparison of symmetrical and asymmetrical cascaded
PDF
Mac protocols for cooperative diversity in wlan
PDF
Automatic anti glare system for night time driving using liquid crystal screens
PDF
Cnt reinforced basalt fiber based ship hulls
PDF
Locational marginal pricing framework in secured dispatch scheduling under co...
PDF
Case study on slender multi storey rc building with brick infill
PDF
Verification of uart ip core using uvm
PDF
Finite element optimization of stator by casted and welded structures
PDF
Fusion of demands in review of bag of-visual words
PDF
A survey on optimal route queries for road networks
PDF
Game theory problems by an alternative simplex method
PDF
Implementation of linux based uart device driver
PDF
The influence of tree induce suction on soil suction
PDF
Process design features of a 5 tonnesday multi – stage, intermittent drainage...
Real time implementation of object tracking through
Detection andprevention of fake access point using sensor nodes
A new approach to minimize stability factor of an amplifier
Status of noise in yeshwanthpur circle (bangalore north) based on on site dat...
Comparative study of various supervisedclassification methodsforanalysing def...
Sequences classification based on group technology
Comparison of symmetrical and asymmetrical cascaded
Mac protocols for cooperative diversity in wlan
Automatic anti glare system for night time driving using liquid crystal screens
Cnt reinforced basalt fiber based ship hulls
Locational marginal pricing framework in secured dispatch scheduling under co...
Case study on slender multi storey rc building with brick infill
Verification of uart ip core using uvm
Finite element optimization of stator by casted and welded structures
Fusion of demands in review of bag of-visual words
A survey on optimal route queries for road networks
Game theory problems by an alternative simplex method
Implementation of linux based uart device driver
The influence of tree induce suction on soil suction
Process design features of a 5 tonnesday multi – stage, intermittent drainage...
Ad

Similar to A fuzzy logic controlled dc dc converter for an (20)

PDF
A comparison of soft switched dc to dc converters for electrolyzer application
PDF
Cs4201628632
PDF
Kf2417451751
PDF
Q25085089
PDF
Experimental Validation of High-V oltage-Ratio LowInput- Current-Ripple DC-DC...
PDF
Reduction of switching losses in vsc using dc link fuzzy logic controller
PDF
11.reduction of switching losses in vsc using dc link fuzzy logic controller
PDF
Novel Zero-Current Switching Current-Fed Half-Bridge Isolated Dc/Dc Converter...
DOCX
A high efficiency step up current-fed
PDF
Single Phase Power Generation System from Fuel Cell
PDF
IRJET- Phase Shifted Full Bridge Converter with Hybrid Energy Storage for Ele...
PDF
New interleaved current fed resonant converter with significantly reduced hig...
PPTX
MAJOR PROJECT on fuzzy logic controlled charger-1.pptx
PPTX
Half_Full_oadfmefonaeofnapw_ednfeio.pptx
PDF
Fuzzy logic controller for closed loop cascaded flyback converter fed PMDC-mo...
PDF
A Single-Stage High-Frequency Isolated Secondary- Side Controlled AC-DC Conve...
PDF
FC/PV Fed SAF with Fuzzy Logic Control for Power Quality Enhancement
PDF
Fpga implementation of race control algorithm for full bridge prcp converter
PDF
Fpga implementation of race control algorithm for full bridge prcp converter
PDF
IRJET- High Efficiency Bridge-Less Battery Charger for Light Electric Veh...
A comparison of soft switched dc to dc converters for electrolyzer application
Cs4201628632
Kf2417451751
Q25085089
Experimental Validation of High-V oltage-Ratio LowInput- Current-Ripple DC-DC...
Reduction of switching losses in vsc using dc link fuzzy logic controller
11.reduction of switching losses in vsc using dc link fuzzy logic controller
Novel Zero-Current Switching Current-Fed Half-Bridge Isolated Dc/Dc Converter...
A high efficiency step up current-fed
Single Phase Power Generation System from Fuel Cell
IRJET- Phase Shifted Full Bridge Converter with Hybrid Energy Storage for Ele...
New interleaved current fed resonant converter with significantly reduced hig...
MAJOR PROJECT on fuzzy logic controlled charger-1.pptx
Half_Full_oadfmefonaeofnapw_ednfeio.pptx
Fuzzy logic controller for closed loop cascaded flyback converter fed PMDC-mo...
A Single-Stage High-Frequency Isolated Secondary- Side Controlled AC-DC Conve...
FC/PV Fed SAF with Fuzzy Logic Control for Power Quality Enhancement
Fpga implementation of race control algorithm for full bridge prcp converter
Fpga implementation of race control algorithm for full bridge prcp converter
IRJET- High Efficiency Bridge-Less Battery Charger for Light Electric Veh...

More from eSAT Publishing House (20)

PDF
Likely impacts of hudhud on the environment of visakhapatnam
PDF
Impact of flood disaster in a drought prone area – case study of alampur vill...
PDF
Hudhud cyclone – a severe disaster in visakhapatnam
PDF
Groundwater investigation using geophysical methods a case study of pydibhim...
PDF
Flood related disasters concerned to urban flooding in bangalore, india
PDF
Enhancing post disaster recovery by optimal infrastructure capacity building
PDF
Effect of lintel and lintel band on the global performance of reinforced conc...
PDF
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
PDF
Wind damage to buildings, infrastrucuture and landscape elements along the be...
PDF
Shear strength of rc deep beam panels – a review
PDF
Role of voluntary teams of professional engineers in dissater management – ex...
PDF
Risk analysis and environmental hazard management
PDF
Review study on performance of seismically tested repaired shear walls
PDF
Monitoring and assessment of air quality with reference to dust particles (pm...
PDF
Low cost wireless sensor networks and smartphone applications for disaster ma...
PDF
Coastal zones – seismic vulnerability an analysis from east coast of india
PDF
Can fracture mechanics predict damage due disaster of structures
PDF
Assessment of seismic susceptibility of rc buildings
PDF
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
PDF
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
Likely impacts of hudhud on the environment of visakhapatnam
Impact of flood disaster in a drought prone area – case study of alampur vill...
Hudhud cyclone – a severe disaster in visakhapatnam
Groundwater investigation using geophysical methods a case study of pydibhim...
Flood related disasters concerned to urban flooding in bangalore, india
Enhancing post disaster recovery by optimal infrastructure capacity building
Effect of lintel and lintel band on the global performance of reinforced conc...
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
Wind damage to buildings, infrastrucuture and landscape elements along the be...
Shear strength of rc deep beam panels – a review
Role of voluntary teams of professional engineers in dissater management – ex...
Risk analysis and environmental hazard management
Review study on performance of seismically tested repaired shear walls
Monitoring and assessment of air quality with reference to dust particles (pm...
Low cost wireless sensor networks and smartphone applications for disaster ma...
Coastal zones – seismic vulnerability an analysis from east coast of india
Can fracture mechanics predict damage due disaster of structures
Assessment of seismic susceptibility of rc buildings
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...

Recently uploaded (20)

PPTX
MET 305 2019 SCHEME MODULE 2 COMPLETE.pptx
PDF
TFEC-4-2020-Design-Guide-for-Timber-Roof-Trusses.pdf
PDF
PREDICTION OF DIABETES FROM ELECTRONIC HEALTH RECORDS
PPTX
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
PDF
Enhancing Cyber Defense Against Zero-Day Attacks using Ensemble Neural Networks
PDF
Automation-in-Manufacturing-Chapter-Introduction.pdf
PDF
Model Code of Practice - Construction Work - 21102022 .pdf
PDF
Operating System & Kernel Study Guide-1 - converted.pdf
PDF
Mohammad Mahdi Farshadian CV - Prospective PhD Student 2026
PPTX
Infosys Presentation by1.Riyan Bagwan 2.Samadhan Naiknavare 3.Gaurav Shinde 4...
DOCX
ASol_English-Language-Literature-Set-1-27-02-2023-converted.docx
PDF
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf
PDF
Unit I ESSENTIAL OF DIGITAL MARKETING.pdf
PPTX
Foundation to blockchain - A guide to Blockchain Tech
PPTX
Sustainable Sites - Green Building Construction
PDF
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
PPTX
Fundamentals of safety and accident prevention -final (1).pptx
PPTX
OOP with Java - Java Introduction (Basics)
PPTX
Construction Project Organization Group 2.pptx
PDF
PPT on Performance Review to get promotions
MET 305 2019 SCHEME MODULE 2 COMPLETE.pptx
TFEC-4-2020-Design-Guide-for-Timber-Roof-Trusses.pdf
PREDICTION OF DIABETES FROM ELECTRONIC HEALTH RECORDS
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
Enhancing Cyber Defense Against Zero-Day Attacks using Ensemble Neural Networks
Automation-in-Manufacturing-Chapter-Introduction.pdf
Model Code of Practice - Construction Work - 21102022 .pdf
Operating System & Kernel Study Guide-1 - converted.pdf
Mohammad Mahdi Farshadian CV - Prospective PhD Student 2026
Infosys Presentation by1.Riyan Bagwan 2.Samadhan Naiknavare 3.Gaurav Shinde 4...
ASol_English-Language-Literature-Set-1-27-02-2023-converted.docx
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf
Unit I ESSENTIAL OF DIGITAL MARKETING.pdf
Foundation to blockchain - A guide to Blockchain Tech
Sustainable Sites - Green Building Construction
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
Fundamentals of safety and accident prevention -final (1).pptx
OOP with Java - Java Introduction (Basics)
Construction Project Organization Group 2.pptx
PPT on Performance Review to get promotions

A fuzzy logic controlled dc dc converter for an

  • 1. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 6 A FUZZY LOGIC CONTROLLED DC-DC CONVERTER FOR AN ELECTROLYZER APPLICATION WITH A VOLTAGE DOUBLER K.Shanthi1, U. Rajesh2, A. Mallikarjuna Prasad3 1EEE Department, St John’s College of Engineering and Technology, Yemmiganur, India 2EEE Department, St John’s College of Engineering and Technology, Yemmiganur, India 3EEE Department, St John’s College of Engineering and Technology, Yemmiganur, India Abstract This paper develops a fuzzy logic controlled dc-dc converter for an electrolyzer application with a voltage doubler. In general day by day usage of power is increasing rapidly but the available resources are exhausting in the near future. Hence we are going for the renewable energy system (RES). It converts the energy into heat or electricity. Electrolyzer is a part of a renewable energy system which converters source power available into hydrogen for fuel cell. But electrolyzer lacks the ability to control the power over rapid changes in input and load , hence a power conditioning system is required to connect the electrolyzer to a system dc bus . Usually a dc-dc converter is used in the most of application .This project deals with the comparison of three soft switched dc-dc converter configurations for an electrolyzer and design of two stage (ZVT boost followed by LCL series resonant converter) with fuzzy logic control. The proposed model has a Zero Voltage switching(ZVS) technique which maintain the soft switching for complete load range. This proposed model is developed and analyzed using MATLAB/Simulink Software and the simulation results obtained justify the accuracy of proposed control technique. Keywords: DC-DC converter, electrolyzer, fuzzy logic controller PI controller, SRC, ZVS, ZVT. ---------------------------------------------------------------------***----------------------------------------------------------------- 1. INTRODUCTION The main drawback of the electrical system is storage .RES in the form of hydrogen storage overcome the weakness of battery based system. Hence an electrolyzer is needed to convert the electricity into hydrogen. The ability to store energy at times when the supply exceeds demands will be a key to the effective utilization of renewable energy. Because many renewable sources (e.g. wind, solar, tidal) are intermittent in nature, storage is useful. The figure 1 shows the schematic diagram of a RES. The basic idea is to keep harvesting the energy resource at a steady rate, regardless of the demand. Usually, this results in the most efficient operation. If the demand is less than full capacity, the excess is diverted into storage medium. in the proposed we go for a hydrogen storage which utilizes excess electric power to produce hydrogen and oxygen from water by means of electrolysis. Energy can be retrieved by running them back through a fuel cell. Fig. 1 schematic of a renewable energy system In this paper we develops a MATLAB/simulink model of three soft-switched high-frequency transformer isolated dc-to- dc converter configurations for electrolyzer. Firstly, we compared the three switching configurations of a dc-dc converter. Among them it is shown that LCL type series resonant converter with capacitive output filter is suitable for this application. Due to the wide variation in input voltage and load current, no converter can maintain zero-voltage switching (ZVS) for the complete operating range. Therefore, a two-stage converter (ZVT boost converter followed by LCL SRC with capacitive output filter) is adapted. later a PI and FUZZY logic control was implemented for a closed loop operation and simulation results are compared. 2. NEED OF A DC-DC CONVERTER To achieve proper voltage matching the main components of the system should be connected to the DC-bus of RES via dc-dc converter. The electrolyzer is interfaced by help of a step-down DC/DC converter, while the fuel cell is connected by help of a step-up DC/DC converter. In principle, any basic power converter topology can be used to design a power interface for a fuel cell and an electrolyzer. Typically, these converters have a high-frequency voltage transformer, which could also perform the function of isolation. The main technology development trend here is to reduce the power losses in the interface converters in order to obtain the highest possible energy efficiency .The following figure2 shows the need of a DC-DC converter.
  • 2. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 7 Fig 2 Energy exchange using dc-dc converter 3. POSSIBLE SOFT SWITCHING CONFIGARATIONS FOR THE ELECTROLYZER APPLICATION Soft switching converters has many advantages over hard switching converters .these soft switching converters had a advantage of reduce voltage/current stress, reduce EMI, reduced switching losses, and allow a greater high frequency in high power applications. There are three major types of HF transformer isolated soft switching converter configurations possible: 1) voltage fed resonant converters 2) current fed resonant converters and 3) fixed-frequency resonant transition zero-voltage switching (ZVS) pulse width modulation (PWM) bridge converters .but current fed resonant converters require HF switches rated at 5–6 times the input voltage which reduces the efficiency. Hence Voltage fed resonant converter with fixed-frequency operation is adopted in this paper. the six soft-switching converter configurations for the electrolyzer application: 1) Fixed-frequency series resonant converter (SRC). 2) Fixed-frequency parallel resonant converter (PRC.) 3) Fixed-frequency series-parallel or LCC-type resonant converter (SPRC). 4) Fixed-frequency LCL SRC with a capacitive output filter. 5) Fixed-frequency LCL SRC with an inductive output filter. 6) Fixed-frequency phase-shifted ZVS PWM full-bridge converter. Among the aforementioned six converter configurations, the SRC and SPRC can operate with the ZVS, only for very narrow variations in supply and load variations in the present application. In the case of PRC, the inverter peak current does not decrease much with reduction in the load current and there is no coupling capacitor in series with the HF transformer. Therefore, the first three configurations are not considered. Table: 1 Comparison of Converters Problems LCL SRC with cap filter LCL SRC with inductive filter Phase shifted PWM converter ZVS range 100%load to 10%load minimum input voltage 100%load to 10%load minimum input voltage 100%load to 10%load minimum input voltage Duty cycle loss Not present Present Present Rectifier ringing Not present Present, requires snubber Present, requires snubber 4. BLOCK DIAGRAM OF A EXISTED SYSTEMS The following figure3 shows the block diagram of a existed system. it consists renewable source input which was given to ZVT boost converter from there it is converted into a high frequency AC using LCL- SRC converter and its output was coupled to a rectifier using HF step down transformer. The DC output of the rectifier is used to feed the electrolyzer plant Fig 3 Block diagram of a existed system 5. BLOCK DIAGRAM OF PROPOSED SYSTEM In this proposed system a voltage doubler is placed instead of rectifier, as it performs the rectification and as well as doubles the output voltage . Vo = 2* Vout Even though existing two stage boost converter system is operating accurately ,for a wide changing load and input sources time to time there is fluctuations in the output .The following figure 4 shows the block diagram of a proposed system.
  • 3. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 8 Fig 4 Block Diagram of A Proposed System 6. RESULTS AND DISCUSSIONS MATLAB is a software package for computation in engineering, science, and applied mathematics. It offers a powerful programming language, excellent graphics, and a wide range of expert knowledge. MATLAB is published by and a trademark of The MathWorks, Inc. 6.1 MATLAB Model for a LCL-SRC with Inductive Filter The following figure5 shows the MATLAB model of a LCL-SRC with an inductive output filter. And the figures 6, 7, 8 shows the input voltage ,voltage across Vab , output voltage Vo .Their values are given as follows Input voltage = 40V Voltage across Vab = 40 V Output voltage Vo = 54 Fig. 5. MATLAB model of a lcl-src with an inductive filter 0 2 4 6 8 10 12 14 x 10 4 -10 0 10 20 30 40 50 60 time output voltage Fig. 6. simulation result showing the output voltage Vo 9500 9600 9700 9800 9900 10000 10100 10200 10300 10400 10500 -50 -40 -30 -20 -10 0 10 20 30 40 50 time voltage at vab Fig. 7. Simulation result showing voltage vab 2.06 2.07 2.08 2.09 2.1 2.11 2.12 2.13 x 10 4 -400 -300 -200 -100 0 100 200 300 400 Fig. 8. Simulation result showing inductor current il 6.2 MATLAB Model for a Fixed-Frequency Phase- Shifted ZVS PWM Full-Bridge Converter The following figure 9 shows the MATLAB model of a LCL-SRC with an inductive output filter. . And the figures 10, 11, 12 shows the input voltage ,voltage across Vab , output voltage Vo .Their values are given as follows Input voltage = 40V Voltage across Vab = 40 V Output voltage Vo = 54 V Fig 9 MATLAB model of a fixed-frequency phase-shifted ZVS PWM full-bridge converter 0 2 4 6 8 10 12 x 10 4 0 5 10 15 20 25 30 35 40 time output voltage Fig. 10. simulation result showing the output voltage Vo
  • 4. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 9 6 6.05 6.1 6.15 6.2 6.25 6.3 x 10 4 -50 -40 -30 -20 -10 0 10 20 30 40 50 Fig. 11. Simulation result showing voltage vab 3450 3500 3550 3600 3650 3700 3750 3800 3850 3900 -40 -20 0 20 40 60 80 time inductor current Fig. 12. Simulation result showing inductor current il 6.3 MATLAB Model for a LCL-SRC with Capacitive Output Filter The following figure 13 shows the MATLAB model of a LCL-SRC with a capacitive output filter. And the figures 14, 15, 16 shows the input voltage ,voltage across Vab , output voltage Vo .Their values are given as follows Input voltage = 40V Voltage across Vab = 40 V Output voltage Vo = 54 V Fig. 13. MATLAB model of a LCL-SRC with a capacitive output filter 0 2 4 6 8 10 12 x 10 4 -20 0 20 40 60 time output voltage Fig. 14. simulation result showing the output voltage Vo 1.18 1.2 1.22 1.24 1.26 1.28 1.3 1.32 1.34 x 10 4 -6 -4 -2 0 2 4 6 time voltage at vab Fig. 15. Simulation result showing voltage vab 2250 2300 2350 2400 2450 2500 2550 2600 2650 2700 2750 -250 -200 -150 -100 -50 0 50 100 150 200 time voltage at vab Fig. 16. Simulation result showing inductor current From the figures 6,10 and 14 it can be say that LCL-SRC with capacitive output filter has a better performance as the peak in the output voltage had reduced to a great extent. and also it maintains the ZVS for changes . 6.4 MATLAB Model for a Two Stage (ZVT Boost LCL-SRC) Approach LCL SRC with capacitive output filter has better performance compared to other configuration, it maintains ZVS for wide change in input voltage. But for wide change in input an extra resonant inductor is required. So a ZVT boost converter is required to boost input. By using this converter the complexity in simplifying the resonant component can be reduced when compared to other approach. This approach not only achieves ZVS for all the switches but also simplifies the design of Lr and Cs resonant components. The following figure 17 shows the MATLAB model of ZVT boost LCL-SRC with capacitive output filter. And the figures 18, 19, 20 shows the input voltage ,voltage across Vab , output voltage Vo .Their values are given as follows Input voltage = 40V
  • 5. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 10 Voltage across Vab = 40 V Output voltage Vo = 60 V Fig. 17. MATLAB model of a LCL-SRC with a capacitive output filter 3.25 3.3 3.35 3.4 3.45 3.5 3.55 x 10 4 -150 -100 -50 0 50 100 150 time vab Fig. 18. Simulation result showing voltage vab 2.46 2.48 2.5 2.52 2.54 2.56 2.58 2.6 2.62 2.64 x 10 4 -400 -300 -200 -100 0 100 200 300 400 time inductor current Fig. 19. Simulation result showing inductor current 0 0.5 1 1.5 2 2.5 3 x 10 5 0 20 40 60 80 100 120 140 160 180 200 time output voltage Fig. 20. Simulation result showing output voltage Vo From the above figure 20 it can observe that smoot output voltage is observed .hence by adopting the ZVT boost at the input side the input is maintained to a constant value hence there by reducing the swithing losses at the inverter 6.5 MATLAB Model for a PI Controller with Voltage Doubler The following figure 21 shows the two stage(ZVT boost LCL-SRC ) with an voltage doubler and a PI controller. At the input side a FUEL cell stack taken as the input source. And the figures 23, 24, 25 shows the input voltage ,voltage across Vab , output voltage Vo .Their values are given as follows Input voltage = 40V Voltage across Vab = 100 V Output voltage Vo = 120V Fig. 21. MATLAB model of a pi controller with voltage doubler Fig. 22. MATLAB model of a subsystem of a PI controller 2000 4000 6000 8000 10000 12000 14000 16000 18000 -150 -100 -50 0 50 100 time vab Fig. 23. Simulation result showing voltage Vab
  • 6. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 11 0 2 4 6 8 10 12 x 10 4 -20 0 20 40 60 80 100 120 140 time vo Fig. 24. Simulation result showing output voltage Vo 0 2 4 6 8 10 12 x 10 4 -600 -400 -200 0 200 400 600 time inductor current Fig. 26. Simulation result showing inductor current 6.6 MATLAB Model of a Fuzzy Logic System The use of fuzzy logic is attractive for control systems since it enables the use of multiple inputs. Fuzzy logic also enables the description of the behavior of the controller using several rules defined by a set of linguistic variables. Hence, FLC is a promising tool for controlling complex, linguistic based systems. The steps to implement the fuzzy logic controller is 1. Create the membership values (fuzzify). 2. Specify the rule table. 3. Determine your procedure for defuzzifying the result. First we have to fuzzify the data or create membership values for the data and put them into fuzzy sets. simply, we have to divide each set of data into ranges. The following figure 27 shows the two stage(ZVT boost LCL-SRC ) with an voltage doubler and a Ffuzzy logic controller. At the input side a FUEL cell stack taken as the input source. And the figures 29, 30, 31 shows the input voltage ,voltage across Vab , output voltage Vo . Fig. 27. MATLAB model of a FUZZY controller with voltage doubler Fig. 28. MATLAB model of a subsystem of a FUZZY controller Fig. 29. fuzzy surface system 1000 2000 3000 4000 5000 6000 7000 8000 -100 -50 0 50 100 time voltage across ab Fig. 30. Simulation result showing voltage Vab 0 2 4 6 8 10 12 x 10 4 -20 0 20 40 60 80 100 120 time output voltage vo Fig. 31. Simulation result showing voltage Vab
  • 7. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Special Issue: 12 | ICAESA - 2014 | Jun-2014, Available @ http://www.ijret.org 12 0 2 4 6 8 10 12 x 10 4 -500 -400 -300 -200 -100 0 100 200 300 400 Fig. 32. Simulation result showing voltage Vab In the above figure 27 a fuzzy logic controller was implemented with mamdani fuzzy inference type.when compared the results of PI and fuzzy controller from the figures 24and 30 it can be shown that even low voltage application also the fuzzy controller can reduce the output distortions.And also it maintains the ZVS for all switches reducing the switching losses. fuell stack rating = 6KW-45V DC no of cells = 65 voltage at Vab = 100 v output voltage = 120 V 7. CONCLUSIONS In this paper a fuzzy logic controlled DC-DC converter for an electrolyzer application has been implemented using MATLAB/simulink. Among available converter configurations it is shown that the a ZVT BOOST along with LCL –SRC converter is best one for the electrolyzer. To reduce the output distortions a PI controller was kept in order to reduce the steady state error. A voltage doubler introduced in the circuit acts as both rectifier and as voltage doubler .the simulation results are checked for both fuzzy and PI controller. It is shown that by using fuzzy logic controlled converter the conversion can be operated smoothly and efficiently for electrolyzer application compared to the other converters. And the output voltage range also doubled . REFERENCES [1] D. Shapiro, J. Duffy, M. Kimble, and M. Pien, “Solar-powered regenerative PEM electrolyzer/fuel cell system,” J. Solar Energy, vol. 79, pp. 544–550, 2005. [2] X. Zhang, H. S.-H. Chung, X. Ruan, and A. Ioinovici, “A ZCS full-bridge converter without voltage overstress on the switches,” IEEE Trans. PowerElectron., vol. 25, no. 3, pp. 686–698, Mar. 201 [3] D. S. Gautam and A. K. S. Bhat, “A two-stage soft-switched converter for electrolyser application,” in Proc. Nat. Power Syst. Conf., Mumbai, India, 2008, pp. 524–528. [4] A.K.S. Bhat, "Analysis and design of LCL-type resonant converter", IEEE Trans. on Industrial Electronics, vol. 41, no. 1, pp. 118-124, Feb. 1994. [5] A.K.S. Bhat, "Analysis and design of a fixed frequency LCL-type series resonant converter," IEEE Trans. on Aerospace and Electronic Systems,vol. 31, no. 1, Jan. 1995, 125-137. [6] Ahmadi, P., Dincer, I., Rosen, M.A., 2013. Energy and exergy analyses of hydrogen production via solar-boosted ocean thermal energy conversion and PEM electrolysis. International Journal of Hydrogen Energy, 38 (4) : 1795- 1805. [doi:10.1016/j.ijhydene.2012.11.025] [7] Arriaga, L.G., Martinez, W., Cano, U., Blud, H., 2007. Direct coupling of a solar-hydrogen system in Mexico. International Journal of Hydrogen Energy, 32 (13): 2247- 2252. [doi:10.1016/j.ijhydene.2006.10.067] [8] Y. Jang and M. M. Jovanovic, “A new family of full-bridge ZVS converters,” IEEE Trans. Power Electron., vol. 19, no. 3, pp. 701–708, May 2004. [9] H. Bodur and A. F. Bakan, “A new ZVT-PWM DC-DC converter,” IEEE Trans. on Power Electr., vol. 17, no. 1, Jan. 2002, pp. 40-47. [10] R. Streit and D. Tollik, “High efficiency telecom rectifier using a novel soft-switched boost based input current shaper”, IEEE INTELC Conf. Record, 1991, pp.720-726. [11] Ferraro, “An overview of low-loss snubber technology for transistor converters,” in Proc. IEEE Power Electron. Spec. Conf., 1982, pp.466–477. [12] G. Hua, C. S. Leu, Y. Jiang, and F. C. Y. Lee, “Novel zero-voltagetransition PWM converters,” IEEE Trans. Power Electron., vol. 9, pp. 213–219, Mar. 1994. 601–606, Nov. 1994. [13] D. S. Gautam and A. K. S. Bhat, “A two-stage soft-switched converter for electrolyser application,” in Proc. Nat. Power Syst. Conf., Mumbai, India, 2008, pp. 524–528.