DF-52386:C • E-810

AD355(A)
ADAPT® Multi-Sensor
Low Profile Intelligent Detector

                                                                                                          Addressable Devices

General
The AD355(A) ADAPT® detector is an intelligent, address-
able, multi-sensing, low-profile detector designed for use with
Fire•Lite Fire Alarm Control Panels.
The ADAPT detector uses a combination of photoelectric and
thermal sensing technologies to increase immunity to false
alarms. Unlike traditional intelligent detectors, the ADAPT
detector has a microprocessor in the detector head that pro-
cesses alarm data. As a result, the ADAPT detector adjusts its
sensitivity automatically, without operator intervention or con-




                                                                                                                                     FAPT-851 with B210.png
trol panel programming.
Areas where the ADAPT detector is especially useful include
office complexes, schools, college campuses, manufacturing
and industrial facilities, and anywhere else the use of a partic-
ular area may change. The ADAPT detector automatically
adjusts its sensitivity to the environment.                                         AD355 in B210LP(A) Base
LiteSpeed™ is a communication protocol developed to greatly
enhance the speed of communication between analog intelli-
gent devices and compatible systems. Intelligent devices com-       with classic CLIP systems; 0.5, 1, 2, 3, and 4%/ft. with FlashS-
municate in a grouped fashion. If one of the devices within the     can systems.
group has new information, the panel’s CPU stops the group          Size: 2.0" (5.3 cm) high; base determines diameter.
poll and concentrates on single points. The net effect is
                                                                      – B210LP(A): 6.1" (15.5 cm) diameter.
response speed greater than five times that of earlier designs.
                                                                      – B501(A): 4.1" (10.4 cm) diameter.
Features                                                              – B200SR(A): 6.875" (17.46 cm) diameter.
                                                                      – B224RB(A): 6.2" (15.748 cm) diameter.
• Automatically adjusts sensitivity levels without operator
  intervention or programming. Sensitivity increases with           Shipping weight: 5.2 oz. (147 g).
  heat.                                                             Operating temperature: 0°C to 38°C (32°F to 100°F).
• Microprocessor-based, combination photo and thermal               UL-Listed velocity range: 0 – 4000 ft./min. (1219.2 m/min.),
  technology.                                                       suitable for installation in ducts.
• Compatible with LiteSpeed™ and CLIP systems.
                                                                    Relative humidity: 10% – 93% noncondensing.
• Addressable-analog communication.
                                                                    Thermal sensing rating: fixed-temperature setpoint 135°F
• Sleek, low-profile design.                                        (57°C).
• Two-wire SLC connection.
• Rotary, decimal addressing: 01-159 with MS-9600UDLS               ELECTRICAL SPECIFICATIONS
  and MS-9600LS series systems, and 01-99 with MS-                  Voltage range: 15 – 32 volts DC peak.
  9200UDLS(C) Firmware 4.                                           Standby current (max. avg.): 300 μA.
• Addresses can be viewed and changed without electronic
                                                                    Loop resistance: 50 ohms maximum; varies according to
  programmers.
                                                                    control panel used. Refer to panel installation manuals.
• Dual bi-color LED design provides 360° viewing angle.
                                                                    LED current (max.): 6.5 mA @ 24 VDC (“ON”).
• LEDs lock red when in alarm. In LiteSpeed™, LEDs flash
  green in standby for normal condition.
                                                                    Installation
• Built-in tamper-resistant feature.
• Constructed of off-white fire-resistant plastic, designed to      The AD355(A) plug-in detector uses a separate base to sim-
  commercial standards, and offers an attractive appearance.        plify installation, service, and maintenance. A special tool
                                                                    allows maintenance personnel to plug-in and remove detec-
• SEMS screws for wiring of the separate base.                      tors without using a ladder. Suitable mounting base boxes
• Several base options, including relay, isolator, and sounder.     include:
• Built-in functional test switch activated by external magnet.     • 4.0" (10.16 cm) square box.
• Listed to UL 268.                                                 • 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box.
                                                                    • Single-gang box (except relay or isolator base).
Specifications                                                      NOTE: The AD355(A) detector has the unique ability to adjust
Sensitivity: auto-adjusting levels: 1 to 2%/ft. and 2 to 4%/ft.     sensitivity according to the environment, based on heat and
with classic CLIP systems; 1 to 2, 2 to 3, and 3 to 4%/ft. with     smoke levels. Avoid installing these detectors in locations that are
LiteSpeed™ systems; fixed-sensitivity levels: 1, 2, and 4%/ft.      susceptible to rapid and high temperature changes. An example of
                                                                    an incorrect application would be near or in line with the output of a
                                                                    self-contained heater.


                                                                                                    DF-52386:C • 12/07/2011 — Page 1 of 2
Agency Listings and Approvals
These listings and approvals apply to the modules specified in
this. In some cases, certain modules or applications may not
be listed by certain approval agencies, or listing may be in pro-
cess. Consult factory for latest listing status.
•   UL Listed: S1059.
•   ULC Listed: S1059.
•   MEA Listed: 243-02-E.
•   FM Approved.
•   CSFM: 7272-0075:0194.

Ordering Information
NOTE: “A” suffix indicates ULC Listed model.
AD355: Low-profile intelligent multi-sensor detector.
AD355A: Same as AD355 but with ULC Listing.
INTELLIGENT BASES
NOTE: “A” suffix indicates ULC Listed model.
NOTE: The detector’s plug-in base can be changed off for special
applications. For details about intelligent bases and their mount-
ing, see DF-60059.
B210LP(A): Plug-in detector base (included); standard U.S.
flanged low-profile mounting base.
B210LPBP: Bulk pack of B210LP; package contains 10.
B501(A): Flangeless mounting base.
B501BP: Bulk pack of B501; package contains 10.
B200SR(A): Intelligent sounder base capable of producing
sound output with ANSI Temporal 3 or continuous tone.
Replaces B501BH series bases in retrofit applications.
B224RB(A): Relay base Screw terminals: up to 14 AWG (2.0
mm²). Relay type Form-C. Rating: 2.0 A @ 30 VDC resistive;
0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive.
B224BI(A): Isolator base. Maximum: 25 devices between iso-
lator bases.
ACCESSORIES
F110: Retrofit flange to convert B210LP to match the
B350LPB350LP profile, or to convert older high-profile bases
to low-profile.
F110BP: Bulk pack of F110; package contains 15.
F210: Replacement flange for B210LP(A) base.
RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Fits U.S.
single-gang electrical box. Supported by B210LP(A) and
B501(A) bases only.
SMB600: Surface mounting kit for use with B210LP(A).
M02-04-00: Test magnet.
M02-09-00: Test magnet with telescoping handle.
XR2B: Detector removal tool. Allows installation and/or
removal of LiteSpeed™ Series detector heads from base in
high ceiling installations.
                                                                           ADAPT® and Fire•Lite are registered trademarks and LiteSpeed™ is a
T55-127-010: Detector removal tool without pole.                           trademark of Honeywell International Inc.
                                                                           ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use
XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524                of this document is strictly prohibited.
m) sections.


                                         This document is not intended to be used for installation purposes.
                                           We try to keep our product information up-to-date and accurate.
                                        We cannot cover all specific applications or anticipate all requirements.
                                               All specifications are subject to change without notice.
                                                                                                                                 Made in the U.S. A.
                             For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.
                                                                    www.firelite.com
Page 2 of 2 — DF-52386:C • 12/07/2011

More Related Content

PDF
Edwards Signaling E-HD Data Sheet
PDF
PDF
NIRDAPD_5x5_Array_1550_v03
PDF
Manual osciloscopio GDS-800
PDF
PDS-002-A-1-DSP4000 (2)
PDF
Honeywell 5808w3-data-sheet
Edwards Signaling E-HD Data Sheet
NIRDAPD_5x5_Array_1550_v03
Manual osciloscopio GDS-800
PDS-002-A-1-DSP4000 (2)
Honeywell 5808w3-data-sheet

What's hot (19)

PDF
Rfs7000 series switch installation guide
PDF
Cable Detection EZiSYSTEM i-Series - EZiCAT Cable Detectors i500, i550, i600,...
PDF
Sarix Cámara Térmica PELCO
PDF
Drager PointGard 2000 Series Gas Detection System
PDF
Motorola rfs6000 series rf switch installation guide
PDF
SenseTek Fireray 3000 datasheet
PDF
Thinlineii ds en
PDF
Tomar Strobecom II Optical Preemption & Priority Control System - Preemption ...
PDF
Tomar Emergency Vehicle Products - Lightbars, LED Lightheads, Self-contained ...
PDF
Tomar Industrial Signalling Products - Visual Signals, LED, Strobe Lighting, ...
PDF
Honeywell 5898-data-sheet
PDF
Process Control (Design Conference 2013)
PPTX
General specifications for energy efficient led based
PDF
Kurth Electronic Short Catalog
PDF
Dräger PIR 7000 Fixed Gas Detector - Spec Sheet
PDF
ACD-V_11-2016 RCK
PDF
Drager Polytron 8720 Fixed Gas Detector - Spec Sheet
PDF
Ds powerscanpm8300
Rfs7000 series switch installation guide
Cable Detection EZiSYSTEM i-Series - EZiCAT Cable Detectors i500, i550, i600,...
Sarix Cámara Térmica PELCO
Drager PointGard 2000 Series Gas Detection System
Motorola rfs6000 series rf switch installation guide
SenseTek Fireray 3000 datasheet
Thinlineii ds en
Tomar Strobecom II Optical Preemption & Priority Control System - Preemption ...
Tomar Emergency Vehicle Products - Lightbars, LED Lightheads, Self-contained ...
Tomar Industrial Signalling Products - Visual Signals, LED, Strobe Lighting, ...
Honeywell 5898-data-sheet
Process Control (Design Conference 2013)
General specifications for energy efficient led based
Kurth Electronic Short Catalog
Dräger PIR 7000 Fixed Gas Detector - Spec Sheet
ACD-V_11-2016 RCK
Drager Polytron 8720 Fixed Gas Detector - Spec Sheet
Ds powerscanpm8300
Ad

Similar to Ad355 (20)

PDF
5808spec
PDF
PDF
Proxpoint plus ds_en
PDF
4351 e hightempthermaldetector
PDF
PDF
Honeywell 5853-data-sheet
PDF
Cfs0077 ul-c-web part8
PDF
Thinlineii ds en
PDF
PDF
PDF
PDF
PDF
5808spec
5808spec
Proxpoint plus ds_en
4351 e hightempthermaldetector
Honeywell 5853-data-sheet
Cfs0077 ul-c-web part8
Thinlineii ds en
5808spec
Ad

More from sanzen enterprises (20)

PDF
PDF
Vm3240va ce cb1e
PDF
PDF
Sv200ma mi1e
PDF
Sc610 cs1e
PDF
Sc610 cs1e
PDF
Cs154 cs1e
PDF
Bs678 cs1e tei rev1
PDF
Bs633a data sheet
PDF
Data sheet en_us_1902186891
PDF
Data sheet en_us_1902186891
PDF
Data sheet en_us_1911721995
PDF
La1 uw24 x column loudspeakers
PDF
Bgt 4139 ts
PDF
Bgt 5504 a
PDF
Bgt 5140 a
PDF
Bgt 9120 ts
PDF
Bgt 9119 as
PDF
Bgt 720 tos
PDF
Bgt 5221 as
Vm3240va ce cb1e
Sv200ma mi1e
Sc610 cs1e
Sc610 cs1e
Cs154 cs1e
Bs678 cs1e tei rev1
Bs633a data sheet
Data sheet en_us_1902186891
Data sheet en_us_1902186891
Data sheet en_us_1911721995
La1 uw24 x column loudspeakers
Bgt 4139 ts
Bgt 5504 a
Bgt 5140 a
Bgt 9120 ts
Bgt 9119 as
Bgt 720 tos
Bgt 5221 as

Ad355

  • 1. DF-52386:C • E-810 AD355(A) ADAPT® Multi-Sensor Low Profile Intelligent Detector Addressable Devices General The AD355(A) ADAPT® detector is an intelligent, address- able, multi-sensing, low-profile detector designed for use with Fire•Lite Fire Alarm Control Panels. The ADAPT detector uses a combination of photoelectric and thermal sensing technologies to increase immunity to false alarms. Unlike traditional intelligent detectors, the ADAPT detector has a microprocessor in the detector head that pro- cesses alarm data. As a result, the ADAPT detector adjusts its sensitivity automatically, without operator intervention or con- FAPT-851 with B210.png trol panel programming. Areas where the ADAPT detector is especially useful include office complexes, schools, college campuses, manufacturing and industrial facilities, and anywhere else the use of a partic- ular area may change. The ADAPT detector automatically adjusts its sensitivity to the environment. AD355 in B210LP(A) Base LiteSpeed™ is a communication protocol developed to greatly enhance the speed of communication between analog intelli- gent devices and compatible systems. Intelligent devices com- with classic CLIP systems; 0.5, 1, 2, 3, and 4%/ft. with FlashS- municate in a grouped fashion. If one of the devices within the can systems. group has new information, the panel’s CPU stops the group Size: 2.0" (5.3 cm) high; base determines diameter. poll and concentrates on single points. The net effect is – B210LP(A): 6.1" (15.5 cm) diameter. response speed greater than five times that of earlier designs. – B501(A): 4.1" (10.4 cm) diameter. Features – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter. • Automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with Shipping weight: 5.2 oz. (147 g). heat. Operating temperature: 0°C to 38°C (32°F to 100°F). • Microprocessor-based, combination photo and thermal UL-Listed velocity range: 0 – 4000 ft./min. (1219.2 m/min.), technology. suitable for installation in ducts. • Compatible with LiteSpeed™ and CLIP systems. Relative humidity: 10% – 93% noncondensing. • Addressable-analog communication. Thermal sensing rating: fixed-temperature setpoint 135°F • Sleek, low-profile design. (57°C). • Two-wire SLC connection. • Rotary, decimal addressing: 01-159 with MS-9600UDLS ELECTRICAL SPECIFICATIONS and MS-9600LS series systems, and 01-99 with MS- Voltage range: 15 – 32 volts DC peak. 9200UDLS(C) Firmware 4. Standby current (max. avg.): 300 μA. • Addresses can be viewed and changed without electronic Loop resistance: 50 ohms maximum; varies according to programmers. control panel used. Refer to panel installation manuals. • Dual bi-color LED design provides 360° viewing angle. LED current (max.): 6.5 mA @ 24 VDC (“ON”). • LEDs lock red when in alarm. In LiteSpeed™, LEDs flash green in standby for normal condition. Installation • Built-in tamper-resistant feature. • Constructed of off-white fire-resistant plastic, designed to The AD355(A) plug-in detector uses a separate base to sim- commercial standards, and offers an attractive appearance. plify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove detec- • SEMS screws for wiring of the separate base. tors without using a ladder. Suitable mounting base boxes • Several base options, including relay, isolator, and sounder. include: • Built-in functional test switch activated by external magnet. • 4.0" (10.16 cm) square box. • Listed to UL 268. • 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. • Single-gang box (except relay or isolator base). Specifications NOTE: The AD355(A) detector has the unique ability to adjust Sensitivity: auto-adjusting levels: 1 to 2%/ft. and 2 to 4%/ft. sensitivity according to the environment, based on heat and with classic CLIP systems; 1 to 2, 2 to 3, and 3 to 4%/ft. with smoke levels. Avoid installing these detectors in locations that are LiteSpeed™ systems; fixed-sensitivity levels: 1, 2, and 4%/ft. susceptible to rapid and high temperature changes. An example of an incorrect application would be near or in line with the output of a self-contained heater. DF-52386:C • 12/07/2011 — Page 1 of 2
  • 2. Agency Listings and Approvals These listings and approvals apply to the modules specified in this. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed: S1059. • ULC Listed: S1059. • MEA Listed: 243-02-E. • FM Approved. • CSFM: 7272-0075:0194. Ordering Information NOTE: “A” suffix indicates ULC Listed model. AD355: Low-profile intelligent multi-sensor detector. AD355A: Same as AD355 but with ULC Listing. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: The detector’s plug-in base can be changed off for special applications. For details about intelligent bases and their mount- ing, see DF-60059. B210LP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Relay base Screw terminals: up to 14 AWG (2.0 mm²). Relay type Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Isolator base. Maximum: 25 devices between iso- lator bases. ACCESSORIES F110: Retrofit flange to convert B210LP to match the B350LPB350LP profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Fits U.S. single-gang electrical box. Supported by B210LP(A) and B501(A) bases only. SMB600: Surface mounting kit for use with B210LP(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of LiteSpeed™ Series detector heads from base in high ceiling installations. ADAPT® and Fire•Lite are registered trademarks and LiteSpeed™ is a T55-127-010: Detector removal tool without pole. trademark of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 of this document is strictly prohibited. m) sections. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 — DF-52386:C • 12/07/2011