SlideShare a Scribd company logo
DC201R Series 
Sold & Serviced By: 
DIGIFLEX® DIGITAL SERVO DRIVES 
WITH CANopen INTERFACE 
MODEL: DC201R30A40NAC 
FEATURES: 
·  Fully digital, state-of-the-art DSP design 
·  Brushed DC, brushless AC drive technology 
·  10 kHz digital current loop, 5 kHz digital velocity loop, 5 kHz 
digital position loop with programmable gain settings 
·  Resolver feedback for sinusoidal commutation 
·  Surface-mount technology 
·  Small size, low cost, ease of use 
·  Isolated CAN bus interface for setup and networking 
·  Supports CANopen communication protocol (DS301) and 
Device Profile for Drives and Motion Control commands 
(DSP-402) 
·  CAN bus address and bit rate selection via DIP-switches 
·  Windows© based DigiFlex® DriveWare setup software via 
CAN interface (operates with third party PC-to-CAN interface) 
·  Operates in torque, velocity or position mode 
·  Single resolver input 
·  3 programmable isolated digital inputs (sinking), sourcing 
inputs optional (-SRC). 
·  3 programmable isolated digital outputs (sinking) 
·  Dedicated isolated limit and home switch inputs 
·  2 programmable analog inputs (14-bit) 
·  1 programmable analog output (10-bit) 
·  Four quadrant regenerative operation 
·  Built-in shunt regulator (external shunt resistor) 
·  Bi-color LED status indicator 
·  Extensive built-in protection against: 
§ over-voltage 
§ under-voltage 
·  short-circuit: phase-phase, phase-ground 
§ over-current 
§ over-temperature 
* Photo for reference only. 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
www.electromate.com 
sales@electromate.com
Sold & Serviced By: 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
ADVANCED MOTION CONTROLS DC201R Series 
SHNT1 
SHNT2 
AC2 
Page 2 of 13 
BLOCK DIAGRAM: 
10K 
10K 
10K 
CAN_V+ 
GNDCAN 
CAN_H 
CAN_L 
RTERM_CAN 
SHIELD_CAN 
DRIVE ENABLE 
GNDIO 
FAULT RESET, HOME, 
POS LIMIT, NEG LIMIT 
GNDIO 
PROGR. INPUT 1..3 
GNDIO 
DRIVE READY 
GNDIO 
PROGR. OUTPUT 1..3 
GNDIO 
+PROGR. ANALOG INPUT 1,2 
-PROGR. ANALOG INPUT 1,2 
PROGR. ANALOG OUTPUT 
CAN INTERFACE 
I/O ISOLATION 
MOTOR FEEDBACK 
www.electromate.com 
sales@electromate.com 
MAIN CONTROLLER 
CURRENT CONTROL 
TORQUE CONTROL 
VELOCITY CONTROL 
POSITION CONTROL 
+ 
- 
+5V 
5.6VZ 
CONTROL 
LOGIC AND 
PROTECTION 
CIRCUIT 
SYSTEM RESET 
GNDSGN 
DC201R30A40NAC 
ISOLATION 
MOTOR A 
MOTOR B 
MOTOR C 
ISOLATION 
LOGIC POWER 
SUPPLY 
POWER 
OUTPUT STAGE 
AC1 
AC3 
FUSE 
SHUNT REG. 
SIN+ 
SIN-COS+ 
COS-REF+ 
REF-/AGND 
DESCRIPTION: 
The DC201R Series digital PWM servo drives are designed to drive brushed and brushless servomotors. These fully 
digital drives can operate in torque, velocity, or position mode. Various feedback signals can be used to close the 
velocity and position loop. The command source can be generated internally or can be supplied externally. In addition 
to motor control, these drives feature dedicated and programmable digital and analog inputs and outputs to enhance 
interfacing with external controllers and devices. 
DC201R Series drives feature a single CAN interface which supports the CANopen protocol (DS301 and DSP402). 
This interface is used for drive configuration and setup as well as online operation in networked applications. Drive 
commissioning can be accomplished through DigiFlex® DriveWare, a fully graphical Windows© based application. 
Torque, velocity, or position commands can be generated from an analog input, a preset index table, or the CAN 
interface. The DC201R Series also feature an interpolated position mode with cubic interpolation for smooth, 
coordinated, multi-axis position control via the CAN interface. A homing routine based on the home switch input and/or 
the encoder index pulse is also implemented. 
All drive and motor parameters are stored in non-volatile memory.
Sold & Serviced By: 
ADVANCED MOTION CONTROLS DC201R Series 
Page 3 of 13 
SPECIFICATIONS: 
POWER STAGE SPECIFICATIONS DC201R30A40NAC 
AC SUPPLY VOLTAGE 40 – 270 VAC, 3-phase, 50 – 60 Hz 
PEAK CURRENT 30A (21.2 Arms) 
MAXIMUM CONTINUOUS CURRENT 15A (10.6 Arms) 
MINIMUM LOAD INDUCTANCE 600 μH 
SWITCHING FREQUENCY 20 kHz 
HEATSINK (BASEPLATE) TEMPERATURE RANGE 0 to 65 ºC, disables at 65 ºC 
POWER DISSIPATION AT CONTINUOUS CURRENT 200W 
MIN. UNDER-VOLTAGE SHUTDOWN 55 VDC 
MAX. OVER-VOLTAGE SHUTDOWN 439 VDC 
BUS CAPACITANCE 1410 μF 
SHUNT RESISTOR External 
SHUNT SWITCH-ON VOLTAGE Programmable 
SHUNT FUSE 3A Motor Delay @ 250VAC 
CAN INTERFACE SUPPLY SPECIFICATIONS 
DC SUPPLY VOLTAGE 7.5 to 13 VDC 
INPUT CURRENT 150 mA max. 
MECHANICAL SPECIFICATIONS 
POWER CONNECTOR: P1 Screw terminal 
MOTOR FEEDBACK CONNECTOR: CN3* 15-pin high density female D-sub 
I/O CONNECTOR: CN2* 26-pin high density female D-sub 
COMMUNICATIONS INTERFACE (CAN): CN1* 9-pin male D-sub 
SIZE 7.95 x 6.18 x 2.76 inches 
202x 157 x 70 mm 
WEIGHT 3 lbs. 
1.5 Kg 
* Mating connectors are not included. 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
www.electromate.com 
sales@electromate.com
Sold & Serviced By: 
ADVANCED MOTION CONTROLS DC201R Series 
Page 4 of 13 
PIN FUNCTIONS: 
P1 - Motor and Power Connector: 
CONNECTOR PIN NAME DESCRIPTION I/O 
1 MA Motor phase A O 
2 MB Motor phase B O 
3 MC Motor phase C O 
4 SHNT1 O 
External shunt resistor connection 
5 SHNT2 
O 
6 AC1 I 
7 AC2 I 
P1 
8 AC3 
AC supply input. 40 – 270 VAC, single 
or 3-phase. 
I 
CN3 - Motor Feedback Connector: 
CONNECTOR PIN NAME DESCRIPTION I/O 
1 SIN+ I 
sine input, 2Vrms 
2 SIN-Resolver 
I 
3 COS+ I 
cosine input, 2Vrms 
4 COS-Resolver 
I 
5 GNDSGN Signal ground GNDSGN 
6 - Not connected 
7 - Not connected 
8 - Not connected 
9 - Not connected 
10 GNDA Analog ground GNDA 
11 REF+ Resolver reference output, 4Vrms, 
O 
12 REF- (same as GNDA) 
50mA, 5kHz O 
13 +5V OUT +5V @ 300mA max. Short-circuit 
protected. 
O 
14 MOTOR OVER TEMP TTL input I 
CN3 
15 SHIELD Motor feedback cable shield. Internally 
connected to GNDSGN 
SHLD 
CN2 – I/O Connector: 
CONNECTOR PIN NAME DESCRIPTION I/O 
1 +24V IN +24V input pull-up (for sourcing 
inputs option only) 
I 
2 PROG INPUT 1 I 
CN2 
3 PROG INPUT 3 
Programmable digital input. Opto-isolated. 
See schematic below. I 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
www.electromate.com 
sales@electromate.com
Sold & Serviced By: 
ADVANCED MOTION CONTROLS DC201R Series 
Page 5 of 13 
OUTPUT 
GNDIO 
4 FAULT RESET 
Fault reset input. Opto-isolated. 
See schematic below. I 
5 PROG OUTPUT 2 Programmable digital output. Opto-isolated. 
See schematic below. 
O 
6 - Reserved 
7 -PROG ANALOG INPUT 1 I 
See pin 16, 17 
8 -PROG ANALOG INPUT 2 
I 
9 GNDSGN Signal ground. GNDSGN 
10 +24V IN +24V input pull-up (for sourcing 
inputs option only) 
I 
11 HOME SWITCH Home switch input. Opto-isolated. 
See schematic below. 
I 
12 PROG INPUT 2 Programmable digital input. Opto-isolated. 
See schematic below. 
I 
13 DRIVE ENABLE Drive enable input. Opto-isolated. 
See schematic below. 
I 
14 PROG OUTPUT 1 Programmable digital output. Opto-isolated. 
O 
15 PROG OUTPUT 3 
See schematic below. O 
16 +PROG ANALOG INPUT 1 Programmable analog input. Opto-isolated. 
I 
17 +PROG ANALOG INPUT 2 
See schematic below. I 
18 SYSTEM RESET 
TTL input. Pull to ground to reset 
drive (same as power cycle). 
Referenced to GNDSGN. 
I 
19 NEGATIVE LIMIT SWITCH Negative limit switch input. Opto-isolated. 
See schematic below. 
I 
20 POSITIVE LIMIT SWITCH Positive limit switch input. Opto-isolated. 
See schematic below. 
I 
21 DRIVE READY Drive ready output. Opto-isolated. 
See schematic below. 
O 
22 GNDIO Isolated ground GNDIO 
23 GNDIO Isolated ground GNDIO 
24 GNDA Analog signal ground. Internally 
connected to GNDSGN 
GNDA 
25 PROG ANALOG OUTPUT 1 Programmable analog output. See 
schematic below. 
O 
26 SHIELD Cable shield. Internally connected 
to GNDSGN 
SHLD 
I/O SCHEMATICS: 
·  Isolated Outputs 
DRIVE READY, PROGRAMMABLE OUTPUT 1…3 
Active maximum voltage +0.7 VDC 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
www.electromate.com 
sales@electromate.com
Sold & Serviced By: 
ADVANCED MOTION CONTROLS DC201R Series 
Page 6 of 13 
Active maximum current 200 mA 
Inactive maximum voltage +30 VDC 
Inactive maximum current 0.01 mA 
INPUT 
GNDIO 
10K 
+24V IN 
INPUT 
10K 
·  Isolated Inputs 
DRIVE ENABLE, FAULT RESET, HOME SWITCH, POSITIVE LIMIT SWITCH, NEGATIVE LIMIT SWITCH, 
PROGRAMMABLE INPUT 1…3 
·  Sinking Inputs (standard version) 
Active maximum voltage +30 VDC 
Active minimum voltage +18 VDC 
Inactive maximum voltage +2.5 VDC 
Inactive minimum voltage –5VDC 
·  Sourcing Inputs (optional –SRC version) 
Active maximum voltage +10VDC 
Active minimum voltage –5VDC 
Inactive maximum voltage +24VIN + 5VDC 
Inactive minimum voltage +24VIN –2.5VDC 
·  Programmable Analog Output 
Voltage Range -10V…+10V 
Resolution 10-bit 
Minimum Load Resistance 2K Ohm 
·  Programmable Analog Inputs 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
www.electromate.com 
sales@electromate.com
Sold & Serviced By: 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
ADVANCED MOTION CONTROLS DC201R Series 
Page 7 of 13 
+ 
- 
0.01uF 
10K 10K 
10K 
10K 10K 
0.01uF 
www.electromate.com 
sales@electromate.com 
Voltage Range 10V…+10V 
Resolution 12-bit 
·  System Reset Input 
+5V 
5.6VZ 
14K 
1K 
0.1uF 
CN1 - Communications Interface (CAN): 
CONNECTOR PIN NAME DESCRIPTION I/O 
2 CAN_L CAN _L bus line (dominant low) I 
3 CAN_GND CAN ground GND 
5 CAN_SHLD CAN shield SHLD 
7 CAN_H CAN_H bus line (dominant high) I 
8 CAN_TERM 
Termination. Connect to CAN_H 
for CAN bus termination (120 
Ohm) 
GND 
CN1 
9 CAN_V+ CAN external supply 
7.5…13 VDC 
I 
DIP SWITCH FUNCTIONS: 
·  CAN Address Setting 
Node-ID SW1 SW2 SW3 SW4 SW5 SW6 
Via CAN OFF OFF OFF OFF OFF OFF 
1 ON OFF OFF OFF OFF OFF 
2 OFF ON OFF OFF OFF OFF 
3 ON ON OFF OFF OFF OFF 
…
Sold & Serviced By: 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
ADVANCED MOTION CONTROLS DC201R Series 
Page 8 of 13 
www.electromate.com 
sales@electromate.com 
63 ON ON ON ON ON ON 
·  CAN Bus Bit Rate Setting 
Bit Rate (bits/sec) SW7 SW8 
Via CAN OFF OFF 
500K OFF ON 
250K ON OFF 
125K ON ON 
·  CAN Bus Termination 
SW10 can be us ed for CAN bus termination. Setting SW10 ON will internally connect the CAN_H signal to CAN_L via 
a 120W resistor. This can be used if the drive is the last node in a CAN network. Setting SW10 OFF will open this 
termination. Note: the CAN_TERM pin can also be used for termination, see below. 
CAN 
TRANSCEIVER 
CAN_H 
CAN_TERM 
CAN_L 
CAN_GND 
SW10 
120 
DIGIFLEX® DRIVEWARE: 
DigiFlex® DriveWare is a Windows© based application that can be used to setup and configure the DigiFlex® series of 
digital servo drives via the CAN interface. This application operates with the following PC-to-CAN interfaces: 
Manufacturer Part Number Style Manufacturer Contact Information 
Advantech PCL-841 ISA-bus www.advantech.com 
IXXAT any any www.ixxat.com 
Kvaser any any www.kvaser.com 
ESD Electronics any any www.esd-electronics.com 
CANopen OBJECT DICTIONARY: 
For more detailed information on CANopen, please visit http://www.can-cia.org/, the official web site of CAN in 
Automation (CiA), the governing body of the CANopen standard. 
I. Communication Profile Objects (DS301): 
1000h: Device_Type 
1001h: Error_register 
1002h: Manufacturer_Status_Register 
1008h: Manufacturer_Device_Name
Sold & Serviced By: 
ADVANCED MOTION CONTROLS DC201R Series 
Page 9 of 13 
1009h: Manufacturer_Hardware_Version 
100Ah: Manufacturer_Software_Version 
100Ch: guard-time 
100Dh: life-time factor 
1010h: store_parameters 
1400h: 1st receive pdo communication parameter 
1401h: 2nd receive pdo communication parameter 
1402h: 3rd receive pdo communication parameter 
1403h: 4th receive pdo communication parameter 
1404h: 5th receive pdo communication parameter 
1414h: 21st receive pdo communication parameter 
1415h: 22nd receive pdo communication parameter 
1416h: 23rd receive pdo communication parameter 
1417h: 24th receive pdo communication parameter 
1600h: 1st receive pdo mapping parameter 
1601h: 2nd receive pdo mapping parameter 
1602h: 3rd receive pdo mapping parameter 
1603h: 4th receive pdo mapping parameter 
1604h: 5th receive pdo mapping parameter 
1614h: 21st receive pdo mapping parameter 
1615h: 22nd receive pdo mapping parameter 
1616h: 23rd receive pdo mapping parameter 
1617h: 24th receive pdo mapping parameter 
1800h: 1st transmit pdo communication parameter 
1802h: 3rd transmit pdo communication parameter 
1803h: 4th transmit pdo communication parameter 
1804h: 5th transmit pdo communication parameter 
1814h: 21st transmit pdo communication parameter 
1815h: 22nd transmit pdo communication parameter 
1816h: 23rd transmit pdo communication parameter 
1817h: 24th transmit pdo communication parameter 
1818h: 25th transmit pdo communication parameter 
1819h: 26th transmit pdo communication parameter 
1A00h: 1st transmit pdo mapping parameter 
1A02h: 3rd transmit pdo mapping parameter 
1A03h: 4th transmit pdo mapping parameter 
1A04h: 5th transmit pdo mapping parameter 
1A14h: 21st transmit pdo mapping parameter 
1A15h: 22nd transmit pdo mapping parameter 
1A16h: 23rd transmit pdo mapping parameter 
1A17h: 24th transmit pdo mapping parameter 
1A18h: 25th transmit pdo mapping parameter 
1A19h: 26th transmit pdo mapping parameter 
II. Drive Profile Objects (DSP402) 
·  Common Objects 
6402h: motor_type 
6403h: motor_catalogue_number 
6404h: motor_manufacturer 
6410h: motor_data 
6510h: drive_data 
6502h: supported_ drive_modes 
6503h: drive_catalogue_number 
6504h: drive_manufacturer 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
www.electromate.com 
sales@electromate.com
Sold & Serviced By: 
ADVANCED MOTION CONTROLS DC201R Series 
Page 10 of 13 
2001h: user_defined_drive_name 
2002h: user_units 
200Eh: active_non_fatal_errors 
200Fh: error_self_reset 
2011h: commutation_sensor_selection_code 
2012h: hall_sensor_parameters 
201Fh: hall_sensor_error_option_code 
2031h: hall_sensor_error_counter 
2032h: hall_sensor_error_counter_limit 
2013h: encoder_parameters 
2020h: encoder_counter 
2021h: encoder_position 
2022h: encoder_index_counter 
2027h: encoder_error_option_c ode 
2023h: encoder_error_counter 
2024h: encoder_error_counter_limit 
2014h: auxiliary_encoder_parameters 
2028h: auxiliary_encoder_counter 
2029h: auxiliary_encoder_position 
202Ah: auxiliary_encoder_index_counter 
2030h: auxiliary_encoder_error_option_code 
202Bh: auxiliary_encoder_error_counter 
202Ch: auxiliary_encoder_error_counter_limit 
2040h: DIP-switch_settings 
20A0h: programmable_digital_inputs 
20A1h: programmable_digital_outputs 
20A2h : programmable_analog_inputs 
20A3h: programmable_analog_outputs 
20A4h: programmable_digital_inputs_polarity 
20A5h: programmable_digital_inputs_function 
20A8h: programmable_digital_outputs_polarity 
20A9h: programmable_digital_outputs_function 
20ACh : programmable_analog_input_parameters 
20AEh: programmable_analog_output_parameters 
20C2h: power_stage_temperature 
20C8h: communication_control 
208Fh: load_inertia 
·  Device Control Objects 
6040h: controlword 
20C4h: controlword_initial_value 
20C5h: auxiliary_controlword 
6041h: statusword 
605Ah: quick_stop_option_code 
605Bh: shutdown_option_code 
605Ch: disable_operation_option_code 
6060h: modes_of_operation 
6061h: modes_of_operation display 
2000h: statusword_1 
2004h: dedicated_digital_inputs 
2005h: dedicated_digital_outputs 
2006h: dedicated_digital_inputs_polarity 
2007h: dedicated_digital_outputs_polarity 
2049h: invert_command 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
www.electromate.com 
sales@electromate.com
Sold & Serviced By: 
ADVANCED MOTION CONTROLS DC201R Series 
Page 11 of 13 
20B0h: trigger_at_value 
20B1h: capture_value 
20B3h: trigger_signal 
20B5h: capture_signal 
20B6h: capture_event 
20C1h: delay_times 
20C3h: motor_overtemperature_option_code 
·  Factor Group Objects 
6090h: velocity_encoder_resolution 
608Fh: position_encoder_resolution 
6093h: position_factor 
6094h: velocity_encoder_factor 
6097h: acceleration_factor 
2079h: analog_torque_command_factor 
207Ah: digital_torque_command_factor 
2081h: analog_velocity_command_factor 
2082h: digital_velocity_command_factor 
2091h: analog_position_command_factor 
2092h: digital_position_command_factor 
·  Profile Position Mode Objects 
607Ah: target_position 
607Dh: software_position_limit 
6086h: motion_profile_type 
607Fh: maximum_profile_velocity 
6081h: profile_velocity 
6083h: profile_acceleration 
6084h: profile_deceleration 
6085h: Quick_stop_deceleration 
·  Homing Mode Objects 
607Ch: home_offset 
6098h: homing_method 
6099h: homing_speeds 
609Ah: homing_acceleration 
·  Position Control Function Objects 
6062h: position_demand_value 
6063h: position_actual_value* 
6064h: position_actual_value 
6067h: position_window 
6068h: position_window_time 
6065h: following_error_window 
6066h: following_error_time_out 
60F4h: following_error_actual_value 
60FBh: position_control_parameter_set 
60FCh: position_demand_value* 
2090h: demand_position_offset 
2093h: position_command_low_pass_filter 
·  Profile Velocity Mode Objects 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
www.electromate.com 
sales@electromate.com
Sold & Serviced By: 
ADVANCED MOTION CONTROLS DC201R Series 
Page 12 of 13 
6069h: velocity_sensor_actual_value 
606Ah: sensor_selection_code 
606Bh: velocity_demand_value 
606Ch: velocity_actual_value 
606Dh: velocity_window 
606Eh: velocity_window_time 
606Fh: velocity_threshold 
6070h: velocity_threshold_time 
60F9h: velocity_control_parameter_set 
60FFh: target_velocity 
2080h: demand_velocity_offset 
2083h: velocity_command_low_pass_filter 
2084h: velocity_error 
·  Profile Torque Mode Objects 
6071h: target_torque 
6072h: max_torque 
6074h: torque_demand_value 
6075h: motor_rated_current 
6076h: motor_rated_torque 
6077h: torque_actual_value 
6078h: current_actual_value 
6079h: dc_link_circuit_voltage 
6087h: torque_slope 
6088h: torque_profile_type 
60F8h: torque_control_parameters 
2010h: rated_voltage 
2070h: current_control_parameter_set 
2074h: target_current_q 
2075h: reference_current_q 
2077h: reference_torque 
2078h: rated_torque_constant 
207Bh: Torque command low pass filter 
ORDERING INFORMATION: 
Standard model: DC201R30A40NACX 
With sourcing inputs: DC201R30A40NACX-SRC 
X indicates the current revision letter. 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
www.electromate.com 
sales@electromate.com
Sold & Serviced By: 
ADVANCED MOTION CONTROLS DC201R Series 
Page 13 of 13 
MOUNTING DIMENSIONS: 
ELECTROMATE 
Toll Free Phone (877) SERVO98 
Toll Free Fax (877) SERV099 
www.electromate.com 
sales@electromate.com

More Related Content

PDF
Advanced motion controls dc201r30a40ldc
PDF
Advanced motion controls dc201r25a20nac
PDF
Advanced motion controls dq111se25a20nac
PDF
Advanced motion controls mc1xzdr
PDF
Advanced motion controls dq111se15a40nac
PDF
Advanced motion controls dq111se20a8bdc qd1
PDF
Advanced motion controls dq111se30a40nac
PDF
Advanced motion controls dq111se40a8bdc
Advanced motion controls dc201r30a40ldc
Advanced motion controls dc201r25a20nac
Advanced motion controls dq111se25a20nac
Advanced motion controls mc1xzdr
Advanced motion controls dq111se15a40nac
Advanced motion controls dq111se20a8bdc qd1
Advanced motion controls dq111se30a40nac
Advanced motion controls dq111se40a8bdc

What's hot (20)

PDF
Advanced motion controls dq111se20a8bdc
PDF
Advanced motion controls dq111se20a8bdc h
PDF
Advanced motion controls dq111se15a40nac h
PDF
Advanced motion controls dq111se25a20nac h
PDF
Advanced motion controls dq111se15a40ldc
PDF
Advanced motion controls dq111se15a40ldc h
PDF
Advanced motion controls zdr150ee12a8ldc
PDF
Advanced motion controls zdr300ee12a8ldc
PDF
Advanced motion controls zdcr300ee12a8ldc
PDF
Advanced motion controls dq111se30a40nac h
PDF
Advanced motion controls dq111se40a8bdc h
PDF
Advanced motion controls dx60co8
PDF
Advanced motion controls dq111ee25a20nac
PDF
Advanced motion controls dr100ee60a40lac
PDF
Advanced motion controls dr100ee15a40lac
PDF
Advanced motion controls dr101ee30a40nac
PDF
Advanced motion controls dr101ee25a20nac
PDF
Advanced motion controls dq111ee20a8bdc
PDF
Advanced motion controls dpqnnie 015b200
PDF
Advanced motion controls dq111ee15a40nac
Advanced motion controls dq111se20a8bdc
Advanced motion controls dq111se20a8bdc h
Advanced motion controls dq111se15a40nac h
Advanced motion controls dq111se25a20nac h
Advanced motion controls dq111se15a40ldc
Advanced motion controls dq111se15a40ldc h
Advanced motion controls zdr150ee12a8ldc
Advanced motion controls zdr300ee12a8ldc
Advanced motion controls zdcr300ee12a8ldc
Advanced motion controls dq111se30a40nac h
Advanced motion controls dq111se40a8bdc h
Advanced motion controls dx60co8
Advanced motion controls dq111ee25a20nac
Advanced motion controls dr100ee60a40lac
Advanced motion controls dr100ee15a40lac
Advanced motion controls dr101ee30a40nac
Advanced motion controls dr101ee25a20nac
Advanced motion controls dq111ee20a8bdc
Advanced motion controls dpqnnie 015b200
Advanced motion controls dq111ee15a40nac
Ad

Similar to Advanced motion controls dc201r30a40nac (20)

PDF
Advanced motion controls dpcanie 015n400
PDF
Advanced motion controls dpcanie c100a400
PDF
Advanced motion controls dpcante 015b200
PDF
Advanced motion controls dpcanie c060a400
PDF
Advanced motion controls dpcanie 015a400
PDF
Advanced motion controls dpcanie 015s400
PDF
Advanced motion controls dpcanie 060a400
PDF
Advanced motion controls dpcants 015b200
PDF
Advanced motion controls dpcania 030a400
PDF
Advanced motion controls dpcanie 100a400
PDF
Advanced motion controls dpeaniu c100a400
PDF
Advanced motion controls dpeaniu c100a400
PDF
Advanced motion controls dpcania 015s400
PDF
Advanced motion controls dpcanie 030a400
PDF
Advanced motion controls dpcants 025b200
PDF
Advanced motion controls dpcania c100a400
PDF
Advanced motion controls dpcants 020b080
PDF
Advanced motion controls dpcante 020b080
PDF
Advanced motion controls dpqnnie 060a800
PDF
Advanced motion controls dzcantu 020b080
Advanced motion controls dpcanie 015n400
Advanced motion controls dpcanie c100a400
Advanced motion controls dpcante 015b200
Advanced motion controls dpcanie c060a400
Advanced motion controls dpcanie 015a400
Advanced motion controls dpcanie 015s400
Advanced motion controls dpcanie 060a400
Advanced motion controls dpcants 015b200
Advanced motion controls dpcania 030a400
Advanced motion controls dpcanie 100a400
Advanced motion controls dpeaniu c100a400
Advanced motion controls dpeaniu c100a400
Advanced motion controls dpcania 015s400
Advanced motion controls dpcanie 030a400
Advanced motion controls dpcants 025b200
Advanced motion controls dpcania c100a400
Advanced motion controls dpcants 020b080
Advanced motion controls dpcante 020b080
Advanced motion controls dpqnnie 060a800
Advanced motion controls dzcantu 020b080
Ad

More from Electromate (20)

DOC
Automated screw thread quality checking using SMAC LAR55 actuator new produc...
PDF
An overview of the various kinematic models in both parallel and serial robot...
PDF
Galil motion control robotic symposium presentation-linear motion from non-li...
PDF
Advanced motion controls robotics symposium presentation-open standard tools ...
PDF
Maxon motor ag robotic symposium presentation-impedance control overview and ...
PDF
Kollmorgen robotic symposium presentation-motor design impacts on the optimiz...
PDF
Harmonic drive llc robotics symposium presentation-designing from the inside ...
PDF
Thomson Linear Dual Shaft Rail 2DA Modular Specs
PDF
Thomson Linear 2DA QuickSlide System with Brake
PDF
Thomson Linear RoundRail 2CA Web Universal Carriage Specs
PDF
Thomson Linear RoundRail 1VC Double End Supported Specs
PDF
Thomson Linear RoundRail 2CA Web Flanged Carriage Specs
PDF
Thomson Linear RoundRail Twin Shaft Web 2CA
PDF
Thomson Linear RoundRail 1VC Double Unsupported Specs
PDF
Thomson Linear WhisperTrak Actuators
PDF
Thomson T-Series Profile Rail
PDF
Thomson Linear RoundRail Accessories Collapsable Bellows Specs
PDF
Thomson Linear Roundrail Dual Shaft Rail 2DA Specs
PDF
Thomson Linear RoundRail Continuous Support 1PC Specs
PDF
Thomson Linear RoundRail Continuous Support 1PB Specs
Automated screw thread quality checking using SMAC LAR55 actuator new produc...
An overview of the various kinematic models in both parallel and serial robot...
Galil motion control robotic symposium presentation-linear motion from non-li...
Advanced motion controls robotics symposium presentation-open standard tools ...
Maxon motor ag robotic symposium presentation-impedance control overview and ...
Kollmorgen robotic symposium presentation-motor design impacts on the optimiz...
Harmonic drive llc robotics symposium presentation-designing from the inside ...
Thomson Linear Dual Shaft Rail 2DA Modular Specs
Thomson Linear 2DA QuickSlide System with Brake
Thomson Linear RoundRail 2CA Web Universal Carriage Specs
Thomson Linear RoundRail 1VC Double End Supported Specs
Thomson Linear RoundRail 2CA Web Flanged Carriage Specs
Thomson Linear RoundRail Twin Shaft Web 2CA
Thomson Linear RoundRail 1VC Double Unsupported Specs
Thomson Linear WhisperTrak Actuators
Thomson T-Series Profile Rail
Thomson Linear RoundRail Accessories Collapsable Bellows Specs
Thomson Linear Roundrail Dual Shaft Rail 2DA Specs
Thomson Linear RoundRail Continuous Support 1PC Specs
Thomson Linear RoundRail Continuous Support 1PB Specs

Recently uploaded (20)

PPTX
KOM of Painting work and Equipment Insulation REV00 update 25-dec.pptx
PPTX
Group 1 Presentation -Planning and Decision Making .pptx
PDF
Agricultural_Statistics_at_a_Glance_2022_0.pdf
PDF
Hindi spoken digit analysis for native and non-native speakers
PDF
Unlocking AI with Model Context Protocol (MCP)
PPTX
1. Introduction to Computer Programming.pptx
PDF
Enhancing emotion recognition model for a student engagement use case through...
PDF
From MVP to Full-Scale Product A Startup’s Software Journey.pdf
PDF
WOOl fibre morphology and structure.pdf for textiles
PDF
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
PDF
Transform Your ITIL® 4 & ITSM Strategy with AI in 2025.pdf
PPTX
cloud_computing_Infrastucture_as_cloud_p
PPTX
A Presentation on Touch Screen Technology
PDF
project resource management chapter-09.pdf
PDF
MIND Revenue Release Quarter 2 2025 Press Release
PDF
Microsoft Solutions Partner Drive Digital Transformation with D365.pdf
PDF
DP Operators-handbook-extract for the Mautical Institute
PDF
Univ-Connecticut-ChatGPT-Presentaion.pdf
PDF
Accuracy of neural networks in brain wave diagnosis of schizophrenia
PPTX
Chapter 5: Probability Theory and Statistics
KOM of Painting work and Equipment Insulation REV00 update 25-dec.pptx
Group 1 Presentation -Planning and Decision Making .pptx
Agricultural_Statistics_at_a_Glance_2022_0.pdf
Hindi spoken digit analysis for native and non-native speakers
Unlocking AI with Model Context Protocol (MCP)
1. Introduction to Computer Programming.pptx
Enhancing emotion recognition model for a student engagement use case through...
From MVP to Full-Scale Product A Startup’s Software Journey.pdf
WOOl fibre morphology and structure.pdf for textiles
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
Transform Your ITIL® 4 & ITSM Strategy with AI in 2025.pdf
cloud_computing_Infrastucture_as_cloud_p
A Presentation on Touch Screen Technology
project resource management chapter-09.pdf
MIND Revenue Release Quarter 2 2025 Press Release
Microsoft Solutions Partner Drive Digital Transformation with D365.pdf
DP Operators-handbook-extract for the Mautical Institute
Univ-Connecticut-ChatGPT-Presentaion.pdf
Accuracy of neural networks in brain wave diagnosis of schizophrenia
Chapter 5: Probability Theory and Statistics

Advanced motion controls dc201r30a40nac

  • 1. DC201R Series Sold & Serviced By: DIGIFLEX® DIGITAL SERVO DRIVES WITH CANopen INTERFACE MODEL: DC201R30A40NAC FEATURES: · Fully digital, state-of-the-art DSP design · Brushed DC, brushless AC drive technology · 10 kHz digital current loop, 5 kHz digital velocity loop, 5 kHz digital position loop with programmable gain settings · Resolver feedback for sinusoidal commutation · Surface-mount technology · Small size, low cost, ease of use · Isolated CAN bus interface for setup and networking · Supports CANopen communication protocol (DS301) and Device Profile for Drives and Motion Control commands (DSP-402) · CAN bus address and bit rate selection via DIP-switches · Windows© based DigiFlex® DriveWare setup software via CAN interface (operates with third party PC-to-CAN interface) · Operates in torque, velocity or position mode · Single resolver input · 3 programmable isolated digital inputs (sinking), sourcing inputs optional (-SRC). · 3 programmable isolated digital outputs (sinking) · Dedicated isolated limit and home switch inputs · 2 programmable analog inputs (14-bit) · 1 programmable analog output (10-bit) · Four quadrant regenerative operation · Built-in shunt regulator (external shunt resistor) · Bi-color LED status indicator · Extensive built-in protection against: § over-voltage § under-voltage · short-circuit: phase-phase, phase-ground § over-current § over-temperature * Photo for reference only. ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com
  • 2. Sold & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 ADVANCED MOTION CONTROLS DC201R Series SHNT1 SHNT2 AC2 Page 2 of 13 BLOCK DIAGRAM: 10K 10K 10K CAN_V+ GNDCAN CAN_H CAN_L RTERM_CAN SHIELD_CAN DRIVE ENABLE GNDIO FAULT RESET, HOME, POS LIMIT, NEG LIMIT GNDIO PROGR. INPUT 1..3 GNDIO DRIVE READY GNDIO PROGR. OUTPUT 1..3 GNDIO +PROGR. ANALOG INPUT 1,2 -PROGR. ANALOG INPUT 1,2 PROGR. ANALOG OUTPUT CAN INTERFACE I/O ISOLATION MOTOR FEEDBACK www.electromate.com sales@electromate.com MAIN CONTROLLER CURRENT CONTROL TORQUE CONTROL VELOCITY CONTROL POSITION CONTROL + - +5V 5.6VZ CONTROL LOGIC AND PROTECTION CIRCUIT SYSTEM RESET GNDSGN DC201R30A40NAC ISOLATION MOTOR A MOTOR B MOTOR C ISOLATION LOGIC POWER SUPPLY POWER OUTPUT STAGE AC1 AC3 FUSE SHUNT REG. SIN+ SIN-COS+ COS-REF+ REF-/AGND DESCRIPTION: The DC201R Series digital PWM servo drives are designed to drive brushed and brushless servomotors. These fully digital drives can operate in torque, velocity, or position mode. Various feedback signals can be used to close the velocity and position loop. The command source can be generated internally or can be supplied externally. In addition to motor control, these drives feature dedicated and programmable digital and analog inputs and outputs to enhance interfacing with external controllers and devices. DC201R Series drives feature a single CAN interface which supports the CANopen protocol (DS301 and DSP402). This interface is used for drive configuration and setup as well as online operation in networked applications. Drive commissioning can be accomplished through DigiFlex® DriveWare, a fully graphical Windows© based application. Torque, velocity, or position commands can be generated from an analog input, a preset index table, or the CAN interface. The DC201R Series also feature an interpolated position mode with cubic interpolation for smooth, coordinated, multi-axis position control via the CAN interface. A homing routine based on the home switch input and/or the encoder index pulse is also implemented. All drive and motor parameters are stored in non-volatile memory.
  • 3. Sold & Serviced By: ADVANCED MOTION CONTROLS DC201R Series Page 3 of 13 SPECIFICATIONS: POWER STAGE SPECIFICATIONS DC201R30A40NAC AC SUPPLY VOLTAGE 40 – 270 VAC, 3-phase, 50 – 60 Hz PEAK CURRENT 30A (21.2 Arms) MAXIMUM CONTINUOUS CURRENT 15A (10.6 Arms) MINIMUM LOAD INDUCTANCE 600 μH SWITCHING FREQUENCY 20 kHz HEATSINK (BASEPLATE) TEMPERATURE RANGE 0 to 65 ºC, disables at 65 ºC POWER DISSIPATION AT CONTINUOUS CURRENT 200W MIN. UNDER-VOLTAGE SHUTDOWN 55 VDC MAX. OVER-VOLTAGE SHUTDOWN 439 VDC BUS CAPACITANCE 1410 μF SHUNT RESISTOR External SHUNT SWITCH-ON VOLTAGE Programmable SHUNT FUSE 3A Motor Delay @ 250VAC CAN INTERFACE SUPPLY SPECIFICATIONS DC SUPPLY VOLTAGE 7.5 to 13 VDC INPUT CURRENT 150 mA max. MECHANICAL SPECIFICATIONS POWER CONNECTOR: P1 Screw terminal MOTOR FEEDBACK CONNECTOR: CN3* 15-pin high density female D-sub I/O CONNECTOR: CN2* 26-pin high density female D-sub COMMUNICATIONS INTERFACE (CAN): CN1* 9-pin male D-sub SIZE 7.95 x 6.18 x 2.76 inches 202x 157 x 70 mm WEIGHT 3 lbs. 1.5 Kg * Mating connectors are not included. ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com
  • 4. Sold & Serviced By: ADVANCED MOTION CONTROLS DC201R Series Page 4 of 13 PIN FUNCTIONS: P1 - Motor and Power Connector: CONNECTOR PIN NAME DESCRIPTION I/O 1 MA Motor phase A O 2 MB Motor phase B O 3 MC Motor phase C O 4 SHNT1 O External shunt resistor connection 5 SHNT2 O 6 AC1 I 7 AC2 I P1 8 AC3 AC supply input. 40 – 270 VAC, single or 3-phase. I CN3 - Motor Feedback Connector: CONNECTOR PIN NAME DESCRIPTION I/O 1 SIN+ I sine input, 2Vrms 2 SIN-Resolver I 3 COS+ I cosine input, 2Vrms 4 COS-Resolver I 5 GNDSGN Signal ground GNDSGN 6 - Not connected 7 - Not connected 8 - Not connected 9 - Not connected 10 GNDA Analog ground GNDA 11 REF+ Resolver reference output, 4Vrms, O 12 REF- (same as GNDA) 50mA, 5kHz O 13 +5V OUT +5V @ 300mA max. Short-circuit protected. O 14 MOTOR OVER TEMP TTL input I CN3 15 SHIELD Motor feedback cable shield. Internally connected to GNDSGN SHLD CN2 – I/O Connector: CONNECTOR PIN NAME DESCRIPTION I/O 1 +24V IN +24V input pull-up (for sourcing inputs option only) I 2 PROG INPUT 1 I CN2 3 PROG INPUT 3 Programmable digital input. Opto-isolated. See schematic below. I ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com
  • 5. Sold & Serviced By: ADVANCED MOTION CONTROLS DC201R Series Page 5 of 13 OUTPUT GNDIO 4 FAULT RESET Fault reset input. Opto-isolated. See schematic below. I 5 PROG OUTPUT 2 Programmable digital output. Opto-isolated. See schematic below. O 6 - Reserved 7 -PROG ANALOG INPUT 1 I See pin 16, 17 8 -PROG ANALOG INPUT 2 I 9 GNDSGN Signal ground. GNDSGN 10 +24V IN +24V input pull-up (for sourcing inputs option only) I 11 HOME SWITCH Home switch input. Opto-isolated. See schematic below. I 12 PROG INPUT 2 Programmable digital input. Opto-isolated. See schematic below. I 13 DRIVE ENABLE Drive enable input. Opto-isolated. See schematic below. I 14 PROG OUTPUT 1 Programmable digital output. Opto-isolated. O 15 PROG OUTPUT 3 See schematic below. O 16 +PROG ANALOG INPUT 1 Programmable analog input. Opto-isolated. I 17 +PROG ANALOG INPUT 2 See schematic below. I 18 SYSTEM RESET TTL input. Pull to ground to reset drive (same as power cycle). Referenced to GNDSGN. I 19 NEGATIVE LIMIT SWITCH Negative limit switch input. Opto-isolated. See schematic below. I 20 POSITIVE LIMIT SWITCH Positive limit switch input. Opto-isolated. See schematic below. I 21 DRIVE READY Drive ready output. Opto-isolated. See schematic below. O 22 GNDIO Isolated ground GNDIO 23 GNDIO Isolated ground GNDIO 24 GNDA Analog signal ground. Internally connected to GNDSGN GNDA 25 PROG ANALOG OUTPUT 1 Programmable analog output. See schematic below. O 26 SHIELD Cable shield. Internally connected to GNDSGN SHLD I/O SCHEMATICS: · Isolated Outputs DRIVE READY, PROGRAMMABLE OUTPUT 1…3 Active maximum voltage +0.7 VDC ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com
  • 6. Sold & Serviced By: ADVANCED MOTION CONTROLS DC201R Series Page 6 of 13 Active maximum current 200 mA Inactive maximum voltage +30 VDC Inactive maximum current 0.01 mA INPUT GNDIO 10K +24V IN INPUT 10K · Isolated Inputs DRIVE ENABLE, FAULT RESET, HOME SWITCH, POSITIVE LIMIT SWITCH, NEGATIVE LIMIT SWITCH, PROGRAMMABLE INPUT 1…3 · Sinking Inputs (standard version) Active maximum voltage +30 VDC Active minimum voltage +18 VDC Inactive maximum voltage +2.5 VDC Inactive minimum voltage –5VDC · Sourcing Inputs (optional –SRC version) Active maximum voltage +10VDC Active minimum voltage –5VDC Inactive maximum voltage +24VIN + 5VDC Inactive minimum voltage +24VIN –2.5VDC · Programmable Analog Output Voltage Range -10V…+10V Resolution 10-bit Minimum Load Resistance 2K Ohm · Programmable Analog Inputs ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com
  • 7. Sold & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 ADVANCED MOTION CONTROLS DC201R Series Page 7 of 13 + - 0.01uF 10K 10K 10K 10K 10K 0.01uF www.electromate.com sales@electromate.com Voltage Range 10V…+10V Resolution 12-bit · System Reset Input +5V 5.6VZ 14K 1K 0.1uF CN1 - Communications Interface (CAN): CONNECTOR PIN NAME DESCRIPTION I/O 2 CAN_L CAN _L bus line (dominant low) I 3 CAN_GND CAN ground GND 5 CAN_SHLD CAN shield SHLD 7 CAN_H CAN_H bus line (dominant high) I 8 CAN_TERM Termination. Connect to CAN_H for CAN bus termination (120 Ohm) GND CN1 9 CAN_V+ CAN external supply 7.5…13 VDC I DIP SWITCH FUNCTIONS: · CAN Address Setting Node-ID SW1 SW2 SW3 SW4 SW5 SW6 Via CAN OFF OFF OFF OFF OFF OFF 1 ON OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF …
  • 8. Sold & Serviced By: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 ADVANCED MOTION CONTROLS DC201R Series Page 8 of 13 www.electromate.com sales@electromate.com 63 ON ON ON ON ON ON · CAN Bus Bit Rate Setting Bit Rate (bits/sec) SW7 SW8 Via CAN OFF OFF 500K OFF ON 250K ON OFF 125K ON ON · CAN Bus Termination SW10 can be us ed for CAN bus termination. Setting SW10 ON will internally connect the CAN_H signal to CAN_L via a 120W resistor. This can be used if the drive is the last node in a CAN network. Setting SW10 OFF will open this termination. Note: the CAN_TERM pin can also be used for termination, see below. CAN TRANSCEIVER CAN_H CAN_TERM CAN_L CAN_GND SW10 120 DIGIFLEX® DRIVEWARE: DigiFlex® DriveWare is a Windows© based application that can be used to setup and configure the DigiFlex® series of digital servo drives via the CAN interface. This application operates with the following PC-to-CAN interfaces: Manufacturer Part Number Style Manufacturer Contact Information Advantech PCL-841 ISA-bus www.advantech.com IXXAT any any www.ixxat.com Kvaser any any www.kvaser.com ESD Electronics any any www.esd-electronics.com CANopen OBJECT DICTIONARY: For more detailed information on CANopen, please visit http://www.can-cia.org/, the official web site of CAN in Automation (CiA), the governing body of the CANopen standard. I. Communication Profile Objects (DS301): 1000h: Device_Type 1001h: Error_register 1002h: Manufacturer_Status_Register 1008h: Manufacturer_Device_Name
  • 9. Sold & Serviced By: ADVANCED MOTION CONTROLS DC201R Series Page 9 of 13 1009h: Manufacturer_Hardware_Version 100Ah: Manufacturer_Software_Version 100Ch: guard-time 100Dh: life-time factor 1010h: store_parameters 1400h: 1st receive pdo communication parameter 1401h: 2nd receive pdo communication parameter 1402h: 3rd receive pdo communication parameter 1403h: 4th receive pdo communication parameter 1404h: 5th receive pdo communication parameter 1414h: 21st receive pdo communication parameter 1415h: 22nd receive pdo communication parameter 1416h: 23rd receive pdo communication parameter 1417h: 24th receive pdo communication parameter 1600h: 1st receive pdo mapping parameter 1601h: 2nd receive pdo mapping parameter 1602h: 3rd receive pdo mapping parameter 1603h: 4th receive pdo mapping parameter 1604h: 5th receive pdo mapping parameter 1614h: 21st receive pdo mapping parameter 1615h: 22nd receive pdo mapping parameter 1616h: 23rd receive pdo mapping parameter 1617h: 24th receive pdo mapping parameter 1800h: 1st transmit pdo communication parameter 1802h: 3rd transmit pdo communication parameter 1803h: 4th transmit pdo communication parameter 1804h: 5th transmit pdo communication parameter 1814h: 21st transmit pdo communication parameter 1815h: 22nd transmit pdo communication parameter 1816h: 23rd transmit pdo communication parameter 1817h: 24th transmit pdo communication parameter 1818h: 25th transmit pdo communication parameter 1819h: 26th transmit pdo communication parameter 1A00h: 1st transmit pdo mapping parameter 1A02h: 3rd transmit pdo mapping parameter 1A03h: 4th transmit pdo mapping parameter 1A04h: 5th transmit pdo mapping parameter 1A14h: 21st transmit pdo mapping parameter 1A15h: 22nd transmit pdo mapping parameter 1A16h: 23rd transmit pdo mapping parameter 1A17h: 24th transmit pdo mapping parameter 1A18h: 25th transmit pdo mapping parameter 1A19h: 26th transmit pdo mapping parameter II. Drive Profile Objects (DSP402) · Common Objects 6402h: motor_type 6403h: motor_catalogue_number 6404h: motor_manufacturer 6410h: motor_data 6510h: drive_data 6502h: supported_ drive_modes 6503h: drive_catalogue_number 6504h: drive_manufacturer ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com
  • 10. Sold & Serviced By: ADVANCED MOTION CONTROLS DC201R Series Page 10 of 13 2001h: user_defined_drive_name 2002h: user_units 200Eh: active_non_fatal_errors 200Fh: error_self_reset 2011h: commutation_sensor_selection_code 2012h: hall_sensor_parameters 201Fh: hall_sensor_error_option_code 2031h: hall_sensor_error_counter 2032h: hall_sensor_error_counter_limit 2013h: encoder_parameters 2020h: encoder_counter 2021h: encoder_position 2022h: encoder_index_counter 2027h: encoder_error_option_c ode 2023h: encoder_error_counter 2024h: encoder_error_counter_limit 2014h: auxiliary_encoder_parameters 2028h: auxiliary_encoder_counter 2029h: auxiliary_encoder_position 202Ah: auxiliary_encoder_index_counter 2030h: auxiliary_encoder_error_option_code 202Bh: auxiliary_encoder_error_counter 202Ch: auxiliary_encoder_error_counter_limit 2040h: DIP-switch_settings 20A0h: programmable_digital_inputs 20A1h: programmable_digital_outputs 20A2h : programmable_analog_inputs 20A3h: programmable_analog_outputs 20A4h: programmable_digital_inputs_polarity 20A5h: programmable_digital_inputs_function 20A8h: programmable_digital_outputs_polarity 20A9h: programmable_digital_outputs_function 20ACh : programmable_analog_input_parameters 20AEh: programmable_analog_output_parameters 20C2h: power_stage_temperature 20C8h: communication_control 208Fh: load_inertia · Device Control Objects 6040h: controlword 20C4h: controlword_initial_value 20C5h: auxiliary_controlword 6041h: statusword 605Ah: quick_stop_option_code 605Bh: shutdown_option_code 605Ch: disable_operation_option_code 6060h: modes_of_operation 6061h: modes_of_operation display 2000h: statusword_1 2004h: dedicated_digital_inputs 2005h: dedicated_digital_outputs 2006h: dedicated_digital_inputs_polarity 2007h: dedicated_digital_outputs_polarity 2049h: invert_command ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com
  • 11. Sold & Serviced By: ADVANCED MOTION CONTROLS DC201R Series Page 11 of 13 20B0h: trigger_at_value 20B1h: capture_value 20B3h: trigger_signal 20B5h: capture_signal 20B6h: capture_event 20C1h: delay_times 20C3h: motor_overtemperature_option_code · Factor Group Objects 6090h: velocity_encoder_resolution 608Fh: position_encoder_resolution 6093h: position_factor 6094h: velocity_encoder_factor 6097h: acceleration_factor 2079h: analog_torque_command_factor 207Ah: digital_torque_command_factor 2081h: analog_velocity_command_factor 2082h: digital_velocity_command_factor 2091h: analog_position_command_factor 2092h: digital_position_command_factor · Profile Position Mode Objects 607Ah: target_position 607Dh: software_position_limit 6086h: motion_profile_type 607Fh: maximum_profile_velocity 6081h: profile_velocity 6083h: profile_acceleration 6084h: profile_deceleration 6085h: Quick_stop_deceleration · Homing Mode Objects 607Ch: home_offset 6098h: homing_method 6099h: homing_speeds 609Ah: homing_acceleration · Position Control Function Objects 6062h: position_demand_value 6063h: position_actual_value* 6064h: position_actual_value 6067h: position_window 6068h: position_window_time 6065h: following_error_window 6066h: following_error_time_out 60F4h: following_error_actual_value 60FBh: position_control_parameter_set 60FCh: position_demand_value* 2090h: demand_position_offset 2093h: position_command_low_pass_filter · Profile Velocity Mode Objects ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com
  • 12. Sold & Serviced By: ADVANCED MOTION CONTROLS DC201R Series Page 12 of 13 6069h: velocity_sensor_actual_value 606Ah: sensor_selection_code 606Bh: velocity_demand_value 606Ch: velocity_actual_value 606Dh: velocity_window 606Eh: velocity_window_time 606Fh: velocity_threshold 6070h: velocity_threshold_time 60F9h: velocity_control_parameter_set 60FFh: target_velocity 2080h: demand_velocity_offset 2083h: velocity_command_low_pass_filter 2084h: velocity_error · Profile Torque Mode Objects 6071h: target_torque 6072h: max_torque 6074h: torque_demand_value 6075h: motor_rated_current 6076h: motor_rated_torque 6077h: torque_actual_value 6078h: current_actual_value 6079h: dc_link_circuit_voltage 6087h: torque_slope 6088h: torque_profile_type 60F8h: torque_control_parameters 2010h: rated_voltage 2070h: current_control_parameter_set 2074h: target_current_q 2075h: reference_current_q 2077h: reference_torque 2078h: rated_torque_constant 207Bh: Torque command low pass filter ORDERING INFORMATION: Standard model: DC201R30A40NACX With sourcing inputs: DC201R30A40NACX-SRC X indicates the current revision letter. ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com
  • 13. Sold & Serviced By: ADVANCED MOTION CONTROLS DC201R Series Page 13 of 13 MOUNTING DIMENSIONS: ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com sales@electromate.com