2
Most read
AGAR CORPORATION
AGAR ID-200 SERIES
INTERFACE CONCENTRATION DETECTOR SYSTEM
Specifications:
SYSTEMS
ID-201 (½ Inch Shaft)
ID-202 (1 ¼ Inch Shaft)
ID-205 (Cable mounted)
FUNCTION
The ID-200 Series Interface Detectors are used for interface
measurement and control in all types of liquid/liquid and
vapor/liquid separation processes. A wide range of models,
process connections, and output options are available for
the control of a wide variety of process installations such
as Tanks, Decanters, Dehydrators, Desalters, Coalescers,
etc. The ID-200 Series advanced control capabilities can
be used to automate upset responses, antifoam and
demulsifier chemical feed systems, and eliminate cross-
contamination of separating phases.
OPERATING RANGE
Emulsion Concentration: 0-100% Hydrocarbon/Water by Volume
Process Temperature: Standard: 32°F to 300°F (0°C to 149°C)
High-Temp: 301°F to 800°F (149°C to 427°C)
Ambient Temperature: -40°F to 180°F
Pressure Rating: Standard: 300 psig (high pressures subject to review)
MATERIALS OF CONSTRUCTION
Probe: Standard: 316 Stainless Steel and Teflon
Optional: Zirconium, Hastalloy, Monel
(Others available on request)
Seals: Standard: Viton (Others i.e., Kalrez and Aflas available on request)
OPTIONAL PROCESS CONNECTION
SH-1"/SS: 1" NPT Seal Housing, 316 Stainless Steel
SH-1"/CS: 1" NPT Seal Housing, Carbon Steel
CF-3/4"/SS: 3/4" NPT Compression Fitting, 316 Stainless Steel
CF-3/4"/CS: 3/4" NPT Compression Fitting, Carbon Steel
Flanged Connections: Available on request
AGAR CORPORATION
5150 Tacoma Drive, Houston TX, 77041, USA
P.O. Box 802127, Houston, TX 77280-2127, USA
Tel: +1-832-476-5100 Fax: +1-832-476-5299
Web Site: www.agarcorp.com Email: sales@agarcorp.com
Agarcorp de Venezuela C.A.
Edif. First, Piso 1, Local 1-B
Calle 75 con Av. 13-A
Maracaibo, Edo. Zulia, Venezuela
Tel/Fax: +58 261 7978646
Email: sales@agar.com.ve
© Agar Corporation Inc. All rights reserved. Specifications may be changed without notice. TB-ID-200
PT Agar Corporation Indonesia
Jalan Teratai B-17
Ciputat Baru, Ciputat
Tangerang 15413, Indonesia
Tel: +62 21 7409206
Email: agarindo@indosat.net.id
Agar Corporation Ltd.
P.O. Box 1782GT
Grand Cayman, BWI
Tel: (345) 945-5242
Fax: (345) 945-5218
MODEL VARIATIONS
ID-201: 1/2” shaft
Standard: 48” (4 Ft.) Minimum: 12” (1 Ft.) Maximum: 120” (10 Ft.)
ID-202: For probe lengths greater than 10 feet, sturdier 1-1/4” shaft assemblies
from 5 foot sections via threaded joints.
ID-205: Shaft replaced by 1/4" cable for suspension of antenna down through
tanks, wells, platform legs, caverns, etc.
ELECTRICAL RATING
ID-201, ID-202, ID-205 Probe: Intrinsically Safe CSA: Class 1, Div.1, Groups C & D, T3C
CENELEC: EEx ia IIB T4 and EEx ia IIC T4
PS-201/Power Supply: 115/240 VAC 50-60 Hz or 12/24 VDC (±20%);
Maximum Power Consumption of 250 Watts
PS-201 Enclosures: Weatherproof (N4X) NEMA 4X
Explosion Proof (N7) NEMA 7 CSA Div.1, Class 1, Groups C&D
Flame-Proof (EEx d) CENELEC EEx d[ia] IIB T4
Wiring Connections: Barrier Terminal Block #18 AWG Maximum Diameter
OUTPUT OPTIONS
ID-201/4-20: Powered 4-20 mA into 400 Ohms Maximum;
4 mA = Oil, or Lowest Water Content
ID-201/RL: Relay Contact 1A; 115V; NO and NC; (SPDT);
Fail Safe On Water or Oil; Adjustable Trip Point
ID-201/RL/4-20: Relay and 4-20mA Options
ID-201/RL/LI: Relay with Local Indicating Lights; Amber = Oil, Blue = Water
ID-201/RL/PN: Relay with Pneumatic Output 75 PSI Maximum; 3-Way Explosion Proof
Valve, 12W, CSA and UL Listed; 1/4" NPT Connections, 3/32" Orifices,
Manual Override, Exhaust Speed Control.
ID-201/RL/420/LI/PN: With All Available Options.
CERTIFICATIONS
CSA Canadian Standards Association - #53314
BASEEFA British Approvals Service for Electrical Equipment in Flammable
Atmospheres - Ex 89C2219 and Ex 94C2223
CENELEC European Committee for Electrical Standardization
GOST-R Russian Approval for Hazardous Areas and Accuracy - A 0217A
JRIIS Japanese Research Institute of Industrial Safety - #C11735

More Related Content

PDF
310118 borrador proy_retie_instalaciones
PDF
EACD Lisbon Debate 2015 Luxury Communications Nuno Duarte Lopes The Luxury Ne...
PDF
UOP-MBA
PDF
Argie bond quant track record
PPTX
Charlie pitch deck new v3
PDF
Impero Anti Trend Report 2016
PDF
¿CONTRIBUYES AL MEDIO AMBIENTE?
310118 borrador proy_retie_instalaciones
EACD Lisbon Debate 2015 Luxury Communications Nuno Duarte Lopes The Luxury Ne...
UOP-MBA
Argie bond quant track record
Charlie pitch deck new v3
Impero Anti Trend Report 2016
¿CONTRIBUYES AL MEDIO AMBIENTE?

Viewers also liked (11)

PPTX
Argh Lessons
PDF
Misleading information note sheet
PDF
Evans smart goal essential standard template
PDF
Publizitate agentziak eta teknologia berriak
PPTX
Statistics on Snapchat
PPT
2016 latest slide la genius meeting
PDF
Surface computing,towards business technology
PPTX
El Curriculo Agazziano Por Myriam Gualoto
PPTX
Fundamentos del international marketing
PPTX
AUTOMOBILE UNDER CHASSIS
PDF
Basic elements of communication
Argh Lessons
Misleading information note sheet
Evans smart goal essential standard template
Publizitate agentziak eta teknologia berriak
Statistics on Snapchat
2016 latest slide la genius meeting
Surface computing,towards business technology
El Curriculo Agazziano Por Myriam Gualoto
Fundamentos del international marketing
AUTOMOBILE UNDER CHASSIS
Basic elements of communication
Ad

Similar to Agar interface probe200_ds (16)

PDF
ACI New Corporate Brochure
PDF
Producto 0164-84713
PDF
180625_W600 PH WCT DIS Wall Mount
PDF
DGA to monitor your Transformer
PDF
Contacting Conductivity Sensors Brochure.pdf
PDF
T switch - att11-endress+hauser datasheet-thermal flow switch
PDF
Indumax cls50 d endress+hauser datasheet-inductive conductivity sensor
PDF
Coriolis rct1000 datasheet badger meter rct1000 with rcsguatda.com/cmx.p018...300 sensors
PDF
Conductivity sensor High-Temperature Applications CLS50
PPTX
Tag numbering system
PDF
Vibrating Tuning Fork Level Switch
PDF
ProScan2 Tank Radar Level Sensor.pdf
PDF
Intuition-9™ Series Water Treatment Controllers Brochure
PDF
United Electric TX200 Pressure Transmitter
PDF
Combination Guided Wave Radar Transmitter and Magnetic Level Gauge
PDF
Magnetostrictive Liquid Level Transmitters
ACI New Corporate Brochure
Producto 0164-84713
180625_W600 PH WCT DIS Wall Mount
DGA to monitor your Transformer
Contacting Conductivity Sensors Brochure.pdf
T switch - att11-endress+hauser datasheet-thermal flow switch
Indumax cls50 d endress+hauser datasheet-inductive conductivity sensor
Coriolis rct1000 datasheet badger meter rct1000 with rcsguatda.com/cmx.p018...300 sensors
Conductivity sensor High-Temperature Applications CLS50
Tag numbering system
Vibrating Tuning Fork Level Switch
ProScan2 Tank Radar Level Sensor.pdf
Intuition-9™ Series Water Treatment Controllers Brochure
United Electric TX200 Pressure Transmitter
Combination Guided Wave Radar Transmitter and Magnetic Level Gauge
Magnetostrictive Liquid Level Transmitters
Ad

Recently uploaded (20)

PDF
Race Reva University – Shaping Future Leaders in Artificial Intelligence
PDF
medical_surgical_nursing_10th_edition_ignatavicius_TEST_BANK_pdf.pdf
PDF
BP 505 T. PHARMACEUTICAL JURISPRUDENCE (UNIT 2).pdf
PDF
BP 704 T. NOVEL DRUG DELIVERY SYSTEMS (UNIT 2).pdf
PDF
What if we spent less time fighting change, and more time building what’s rig...
PPTX
Virtual and Augmented Reality in Current Scenario
PPTX
B.Sc. DS Unit 2 Software Engineering.pptx
PPTX
Introduction to pro and eukaryotes and differences.pptx
PDF
English Textual Question & Ans (12th Class).pdf
PDF
LIFE & LIVING TRILOGY - PART (3) REALITY & MYSTERY.pdf
PDF
LEARNERS WITH ADDITIONAL NEEDS ProfEd Topic
PDF
FOISHS ANNUAL IMPLEMENTATION PLAN 2025.pdf
PDF
semiconductor packaging in vlsi design fab
PDF
Complications of Minimal Access-Surgery.pdf
PDF
AI-driven educational solutions for real-life interventions in the Philippine...
PPTX
Module on health assessment of CHN. pptx
PDF
CISA (Certified Information Systems Auditor) Domain-Wise Summary.pdf
PDF
MBA _Common_ 2nd year Syllabus _2021-22_.pdf
PPTX
Unit 4 Computer Architecture Multicore Processor.pptx
PDF
My India Quiz Book_20210205121199924.pdf
Race Reva University – Shaping Future Leaders in Artificial Intelligence
medical_surgical_nursing_10th_edition_ignatavicius_TEST_BANK_pdf.pdf
BP 505 T. PHARMACEUTICAL JURISPRUDENCE (UNIT 2).pdf
BP 704 T. NOVEL DRUG DELIVERY SYSTEMS (UNIT 2).pdf
What if we spent less time fighting change, and more time building what’s rig...
Virtual and Augmented Reality in Current Scenario
B.Sc. DS Unit 2 Software Engineering.pptx
Introduction to pro and eukaryotes and differences.pptx
English Textual Question & Ans (12th Class).pdf
LIFE & LIVING TRILOGY - PART (3) REALITY & MYSTERY.pdf
LEARNERS WITH ADDITIONAL NEEDS ProfEd Topic
FOISHS ANNUAL IMPLEMENTATION PLAN 2025.pdf
semiconductor packaging in vlsi design fab
Complications of Minimal Access-Surgery.pdf
AI-driven educational solutions for real-life interventions in the Philippine...
Module on health assessment of CHN. pptx
CISA (Certified Information Systems Auditor) Domain-Wise Summary.pdf
MBA _Common_ 2nd year Syllabus _2021-22_.pdf
Unit 4 Computer Architecture Multicore Processor.pptx
My India Quiz Book_20210205121199924.pdf

Agar interface probe200_ds

  • 1. AGAR CORPORATION AGAR ID-200 SERIES INTERFACE CONCENTRATION DETECTOR SYSTEM Specifications: SYSTEMS ID-201 (½ Inch Shaft) ID-202 (1 ¼ Inch Shaft) ID-205 (Cable mounted) FUNCTION The ID-200 Series Interface Detectors are used for interface measurement and control in all types of liquid/liquid and vapor/liquid separation processes. A wide range of models, process connections, and output options are available for the control of a wide variety of process installations such as Tanks, Decanters, Dehydrators, Desalters, Coalescers, etc. The ID-200 Series advanced control capabilities can be used to automate upset responses, antifoam and demulsifier chemical feed systems, and eliminate cross- contamination of separating phases. OPERATING RANGE Emulsion Concentration: 0-100% Hydrocarbon/Water by Volume Process Temperature: Standard: 32°F to 300°F (0°C to 149°C) High-Temp: 301°F to 800°F (149°C to 427°C) Ambient Temperature: -40°F to 180°F Pressure Rating: Standard: 300 psig (high pressures subject to review) MATERIALS OF CONSTRUCTION Probe: Standard: 316 Stainless Steel and Teflon Optional: Zirconium, Hastalloy, Monel (Others available on request) Seals: Standard: Viton (Others i.e., Kalrez and Aflas available on request) OPTIONAL PROCESS CONNECTION SH-1"/SS: 1" NPT Seal Housing, 316 Stainless Steel SH-1"/CS: 1" NPT Seal Housing, Carbon Steel CF-3/4"/SS: 3/4" NPT Compression Fitting, 316 Stainless Steel CF-3/4"/CS: 3/4" NPT Compression Fitting, Carbon Steel Flanged Connections: Available on request
  • 2. AGAR CORPORATION 5150 Tacoma Drive, Houston TX, 77041, USA P.O. Box 802127, Houston, TX 77280-2127, USA Tel: +1-832-476-5100 Fax: +1-832-476-5299 Web Site: www.agarcorp.com Email: sales@agarcorp.com Agarcorp de Venezuela C.A. Edif. First, Piso 1, Local 1-B Calle 75 con Av. 13-A Maracaibo, Edo. Zulia, Venezuela Tel/Fax: +58 261 7978646 Email: sales@agar.com.ve © Agar Corporation Inc. All rights reserved. Specifications may be changed without notice. TB-ID-200 PT Agar Corporation Indonesia Jalan Teratai B-17 Ciputat Baru, Ciputat Tangerang 15413, Indonesia Tel: +62 21 7409206 Email: agarindo@indosat.net.id Agar Corporation Ltd. P.O. Box 1782GT Grand Cayman, BWI Tel: (345) 945-5242 Fax: (345) 945-5218 MODEL VARIATIONS ID-201: 1/2” shaft Standard: 48” (4 Ft.) Minimum: 12” (1 Ft.) Maximum: 120” (10 Ft.) ID-202: For probe lengths greater than 10 feet, sturdier 1-1/4” shaft assemblies from 5 foot sections via threaded joints. ID-205: Shaft replaced by 1/4" cable for suspension of antenna down through tanks, wells, platform legs, caverns, etc. ELECTRICAL RATING ID-201, ID-202, ID-205 Probe: Intrinsically Safe CSA: Class 1, Div.1, Groups C & D, T3C CENELEC: EEx ia IIB T4 and EEx ia IIC T4 PS-201/Power Supply: 115/240 VAC 50-60 Hz or 12/24 VDC (±20%); Maximum Power Consumption of 250 Watts PS-201 Enclosures: Weatherproof (N4X) NEMA 4X Explosion Proof (N7) NEMA 7 CSA Div.1, Class 1, Groups C&D Flame-Proof (EEx d) CENELEC EEx d[ia] IIB T4 Wiring Connections: Barrier Terminal Block #18 AWG Maximum Diameter OUTPUT OPTIONS ID-201/4-20: Powered 4-20 mA into 400 Ohms Maximum; 4 mA = Oil, or Lowest Water Content ID-201/RL: Relay Contact 1A; 115V; NO and NC; (SPDT); Fail Safe On Water or Oil; Adjustable Trip Point ID-201/RL/4-20: Relay and 4-20mA Options ID-201/RL/LI: Relay with Local Indicating Lights; Amber = Oil, Blue = Water ID-201/RL/PN: Relay with Pneumatic Output 75 PSI Maximum; 3-Way Explosion Proof Valve, 12W, CSA and UL Listed; 1/4" NPT Connections, 3/32" Orifices, Manual Override, Exhaust Speed Control. ID-201/RL/420/LI/PN: With All Available Options. CERTIFICATIONS CSA Canadian Standards Association - #53314 BASEEFA British Approvals Service for Electrical Equipment in Flammable Atmospheres - Ex 89C2219 and Ex 94C2223 CENELEC European Committee for Electrical Standardization GOST-R Russian Approval for Hazardous Areas and Accuracy - A 0217A JRIIS Japanese Research Institute of Industrial Safety - #C11735