Abstract
In reinforced concrete frame building, masonry wall are generally used in as infills and specified by architects as partitions in
such a way that they do not contribute to the vertical gravity load-bearing capacity of the structure. Infill walls protect the inside
of the buildings from the environment hazards and create separation insides. In addition to this infills have a considerable
strength and stiffness and they have significant effect on the seismic response of the structural systems. Mostly two common
structural damages observed caused by masonry infill walls in earthquakes i.e soft stories and short columns. In office or
residential building outer side central opening are used. In this case central opening are provided in periphery wall with different
percentage i.e. 15% and 25% and brick compressive strength are used as per IS : 1905-1987 i.e. 5.0 and 12.5 N/mm2
and Brick
Masonry strength is 0.50 and 1.06N/mm2
. In ETABS software G+9 R.C.C framed building models has been prepared, Seismic
coefficient method(SCM) and time-history(TH) has been performed for analysis as per IS 1893:2002. Story displacement, base
shear, story drift, axial force with and without soft story considering effect of infill walls with different percentage of opening are
the parameters considered in this study. For Macro model, Equivalent diagonal strut (EDS) method is used to find out width of
strut using FEMA approach method. The results of bare frame, soft story and infill wall panel are discussed and conclusions are
made in this studies.
Key Words: Base shear, Displacement, Equivalent Diagonal Strut, Storey Drift, Soft storey.
--------------------------------------------------------------------***----------------------------------------------------------------------
1. INTRODUCTION
In RC frame brick walls is just architectural point of view
and to make partition and other aspect. In multistory
buildings, the ordinarily occurring vertical loads i.e. dead or
alive, do not cause much of a effects, but the lateral loads
due to wind or earthquake tremors are a matter of great
concern and need special consideration in the design of
buildings. These lateral forces can produce the critical stress
in a structure, set up undesirable vibrations, and in addition,
cause lateral sway of the structure which can reach a stage
of discomfort to the occupants. In many countries situated in
seismic regions, reinforced concrete frames are infilled fully
or partially by brick masonry panels with or without
openings. Although the infill panels significantly enhance
both the stiffness and strength of the frame, their
contribution is often not taken into account because of the
lack of knowledge of the composite behavior of the frame
and the infill. During the elastic response phase, the
presence of brick infill walls increases in plane lateral
stiffness of the structure and reduced its fundamental
period, and as a result leads to larger shear forces.
In residential building RC frame structure are infill by brick
panels on all four sides and resisting the lateral earthquake
loads on building. By experimentally it has been shown that
brick walls have high initial lateral stiffness (Moghaddam
and Dowling 1987, Drysdale et al. 1999, Paulay and
Priestley 1992,). Hence masonry infills in RC frames
different lateral load transfer mechanism of the structure
from predominant frame action to predominant truss action
(Murty and Jain 2000). Shown in Figure 1 below. Thus it is
responsible for increase in axial forces in the RC frame.
Fig -1: Change in lateral-load transfer mechanism due to masonry infill
(Murty and Jain 2000)
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 77
2. LITERATURE REVIEW
From several research paper studies it shows that Equivalent
diagonal strut method is used for modeling the brick infill
wall to easy represent the effect of inplane during lateral
load and its equations for Equivalent diagonal strut width for
full infill given by various researchers are,
In 1961 Holmes,
w = dz/3 where, dz = Diagonal length of
infill panel
In 1962 Equivalent diagonal strut according to Smith,
here
and
In 1969 Smith and Carter,
where
In 1971 Mainstone,
w = 0.175dz (λhH’)-0.4
In 1984 Liaw and Kwan,
w = (0.95Hcosθ)/ √λhH’
In 1992 Paulay & Priestley,
w = dz/4
3. RESEARCH OBJECTIVES
The main objective of this paper is to simplify the analysis
concept of the building industry. And also carry out the
effect of brick masonry infilled walls for the static linear
analysis and Time history analysis of the R.C.C high rise
building with single diagonal strut approach as per IS
1893:2002 and IS 456:2000. The result would be carried out
and compare for G+9 story R.C.C. building.
4. METHOD OF ANALYSIS OF THE BRICK
INFILL WALL
4.1 Data Taken
Table -1: Data for Building
4.2 Types of Model
Table -2: Types of Model
ID
(The First value
indicates masonry
comp. stress,
N/mm2
)
Description
0.5BFGSS15%
Bare frame ground soft story with
15% outer central opening
0.5SFGSS15%
Strut frame ground soft story with
15% outer central opening
1.06BFGSS15%
Bare frame ground soft story with
15% outer central opening
1.06SFGSS15%
Strut frame ground soft story with
15% outer central opening
0.5BFGSS25%
Bare frame ground soft story with
25% outer central opening
0.5SFGSS25%
Strut frame ground soft story with
25% outer central opening
1.06BFGSS25%
Bare frame ground soft story with
25% outer central opening
Story = G+8 4x3 bay
Ground floor height = 3.0m
Typ. story height= 2.9m
Basement height= 3.0m
Beam= 230 x 450 mm
Column= 500 x 500mm
Spacing of frame X direction= 3m
Spacing of frame Y direction= 3m
Live load= 1.5 kn/m2
for terrace
3.0 kn/m2
for typ floor
Dead load= 2.0 kn/m2
for terrace
1.0 kn/m2
for typ floor
Response Reduction Factor, R= 3 for SMRF
Importance factor, I= 1.0
Type of soil= Medium
Damping of structure= 5%
Grade of concrete= M30
Steel= Fe 415
Density of concrete= 25 kn/m3
Density of brick wall= 20 kn/m3
Modulus of elasticity of
concrete, Ec=
27.386 x 106
kn/m2
Modulus of elasticity masonry,
Em=
1)0.275 x 106
kn/m2
2)0.583 x 106
kn/m2
Thick. of outer Brick wall= 115 mm
Thick. of inner Brick wall= 115 mm
Thick. of slab= 125mm
Poisson ratio of concrete= 0.2
Poisson ratio of brick wall= 0.17
Seismic zone= V
Z = 0.36
Time history Bhuj_Ahmedabad
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 78
1.06SFGSS25%
Strut frame ground soft story with
25% outer central opening
0.5BFWSS15%
Bare frame without soft story with
15% outer central opening
0.5SFWSS15%
Strut frame without soft story
with 15% outer central opening
1.06BFWSS15%
Bare frame without soft story with
15% outer central opening
1.06SFWSS15%
Strut frame without soft story
with 15% outer central opening
0.5BFWSS25%
Bare frame without soft story with
25% outer central opening
0.5SFWSS25%
Strut frame without soft story
with 25% outer central opening
1.06BFWSS25%
Bare frame without soft story
with 25% outer central opening
1.06SFWSS25%
Strut frame without soft story
with 25% outer central opening
4.3 Modelling of Brick Infill Wall
Fig -2: Plan
4.4 FEMA Approach
Equivalent diagonal strut method is used for modeling the
brick infill wall according to FEMA273.The infill frame in
this model was assumed as an equivalent diagonal strut
with frame the pin joint(hinge joint) at the corners of the RC
frame(See Fig.5).
In this method the brick infill wall replaced by diagonal
strut. The frame is analyzed as truss element.
The equivalent diagonal strut width is given as:
w = 0.175(λ1hcol
)-0.4
rinf………………eqn
1
Where, λ1 =
Fig- 5 Diagonal strut with pinned joint
And
hcol =Column height between centerlines of beams,m
hinf = Height of infill panel, m
Efe =Expected modulus of elasticity of frame
material,kn/m2
Eme =Expected modulus of elasticity of infill material,
kn/m2
Icol = Moment of inertia of column, m4
Linf = Length of infill panel, m
rinf = Diagonal length of infill panel, m
tinf =Thickness of infill panel and equivalent strut, m
θ =Angle whose tangent is the infill height-to-length
aspect ratio, radians
λ1 = Coefficient used to determine equivalent width of
infill strut
BEA
M
COLUMN
EDS
Hinge
Fig- 3 3D View
of Bare Frame
Fig- 4 3D View
of Strut Frame
BEAM
COLUMN
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 79
4.5 Strut Reduction Factor
Reduction factor
λ=1-2αw
0.54
+αw
1.14
The above coefficient (ʎ) could be used to find the
equivalent width of a strut for the case of an infill with
opening by multiplying the results of Eqns. 1 above for
central opening.
4.6 Modulus of elasticity of brick masonry
In lieu of prism tests, values for the modulus of elasticity of
masonry in compression shall be taken as, 550 times the
expected masonry compressive strength, fme.
i) Compressive strength, fme = 0.5MPa
(IS 1905:1998, Table-8)
Em= 550 x fme = 550 x 0.5 x 103
= 0.275 x 106
kn/m2
ii) Compressive strength, fme = 1.06MPa
(IS 1905:1998, Table-8)
Em= 550 x fme = 550 x 1.06 x 103
= 0.583 x 106
kn/m2
4.7 Fundamental Natural Period of Vibration, (Ts)
Ts= 0.09h/sqrt(d)
Tx = 0.8314 s, Ty = 0.96 s
Where, h = Height of building, in m
d = Base dimension of the building at the plinth level, in m
4.8 Average Response Acceleration Coefficient
(Sa/g)x = 1.36/T = 1.635826
(Sa/g)y = 1.36/T = 1.416667
5. RESULT AND DISCUSSION
5.1 Base Shear
The design base shear Vb as per IS: 1893 shall be calculated
by following formula,
Vb = Ah x W
Where, Ahx,y = ZIS/2RG
Ahx = 0.069949
Ahy = 0.049461
Table -3: Base shear
BASE SHEAR IN X-DIRECTION(KN)
ID SCM TH
0.5BFGSS15% 1549.31 1222.84
0.5SFGSS15% 1549.31 1178.59
1.06BFGSS15% 1549.31 1222.84
1.06SFGSS15% 1549.31 1379.87
0.5BFGSS25% 1519.63 1196.86
0.5SFGSS25% 1519.63 1155.00
1.06BFGSS25% 1519.63 1196.86
1.06SFGSS25% 1519.63 1348.81
0.5BFWSS15% 1595.76 1233.61
0.5SFWSS15% 1595.77 1202.23
1.06BFWSS15% 1595.76 1233.61
1.06SFWSS15% 1595.77 1693.92
0.5BFWSS25% 1566.01 1208.23
0.5SFWSS25% 1566.01 1186.65
1.06BFWSS25% 1566.01 1208.23
1.06SFWSS25% 1566.01 1652.86
Chart -1: Base shear at base in X Direction (Kn)
We can conclude from this analysis that with increase in
stiffness of infill wall base shear of building also increase
thus stiffness of wall is should be minimum.
5.2 Displacement
0
0.2
0.4
0.6
0.8
1
1.2
0 50 100 150
Reductionfactorλ
Opening %
0
500
1000
1500
2000
0.5BFGSS15%
0.5SFGSS15%
1.06BFGSS15%
1.06SFGSS15%
0.5BFGSS25%
0.5SFGSS25%
1.06BFGSS25%
1.06SFGSS25%
0.5BFWSS15%
0.5SFWSS15%
1.06BFWSS15%
1.06SFWSS15%
0.5BFWSS25%
0.5SFWSS25%
1.06BFWSS25%
1.06SFWSS25%
BASE SHEAR IN X-DIR.
SCM TH
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 80
Table -4: Displacement at the top level
DISPLACEMENT AT ROOF LEVEL IN MM
SR
NO.
ID SCM TH
1 0.5BFGSS15% 51.2 31.55
2 0.5SFGSS15% 44.59 27.37
3 1.06BFGSS15% 51.2 31.55
4 1.06SFGSS15% 39.42 31.21
5 0.5BFGSS25% 50.28 31.45
6 0.5SFGSS25% 44.34 27.64
7 1.06BFGSS25% 50.28 31.45
8 1.06SFGSS25% 39.56 31.19
9 0.5BFWSS15% 52.7 31.69
10 0.5SFWSS15% 44.74 28.95
11 1.06BFWSS15% 52.7 31.69
12 1.06SFWSS15% 38.63 32.58
13 0.5BFWSS25% 51.78 31.6
14 0.5SFWSS25% 44.52 29.19
15 1.06BFWSS25% 51.78 31.6
16 1.06SFWSS25% 38.81 32.61
Chart -2: Displacement at the top in X Direction
The displacement in X direction for diff. models are shown
in Graph 2. From graph it can be concluded that with
increase in stiffness of infill wall displacement of building
decreased by 12% to 25 %( see Table 4) in Static and
Dynamic analysis.
5.3 Story Drift
The drift value for SCM and TH analysis results are shown
in followings different chart in mm (see Chart 3 to 6).
Chart-3: Story Drift for SCM in X direction (0.5)
Chart-4: Story Drift for SCM in X direction (1.06)
0
10
20
30
40
50
60
0.5BFGSS15%
0.5SFGSS15%
1.06BFGSS15%
1.06SFGSS15%
0.5BFGSS25%
0.5SFGSS25%
1.06BFGSS25%
1.06SFGSS25%
0.5BFWSS15%
0.5SFWSS15%
1.06BFWSS15%
1.06SFWSS15%
0.5BFWSS25%
0.5SFWSS25%
1.06BFWSS25%
1.06SFWSS25%
DISPLACEMENT IN MM X-DIR.
SCM TH
0
1
2
3
4
5
6
7
8
9
10
0 2 4 6 8
STORYNO.
DRIFT IN MM
SCM-STORY DRIFT FOR 0.5N/MM 2
0.5BFGSS15% 0.5BFGSS25%
0.5BFWSS15% 0.5BFWSS25%
0.5SFGSS15% 0.5SFGSS25%
0.5SFWSS15% 0.5SFWSS25%
0
1
2
3
4
5
6
7
8
9
10
0 2 4 6 8
STORYNO.
DRIFT
SCM-STORY DRIFT FOR 1.06 N/MM 2
1.06BFGSS15% 1.06BFGSS25%
1.06BFWSS15% 1.06BFWSS25%
1.06SFGSS15% 1.06SFGSS25%
1.06SFWSS15% 1.06SFWSS25%
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 81
Chart-5: Story Drift for TH in X direction (0.5)
Chart-6: Story Drift for TH in X direction (1.06)
The drift value has a particular importance of serviceability
requirement. According to Indian seismic code IS 1893 Part-
1 :2002, The story drift in any story due to the minimum
specified design lateral force, with partial load factor of 1.0,
shall not exceed 0.004 * h, where h = story height.
In building with strut, Story drift is less as compared to
without considering strut type building in both direction, i.e.
and Y.(See Chart 3 to 6). All story drift are found to be
within permissible limit i.e. 1.2 cm.
5.4 Axial Force
The maximum axial force in the column are as shown in
following,
Table 5: Maximum Axial Force (kn) on column at Base in
EQ-X
0.5BFGSS15% & 1.06BFGSS15% 0.5BFGSS25% & 1.06BFGSS25%
0.5SFGSS15%
1.06SFGSS15%
0
1
2
3
4
5
6
7
8
9
10
0 1 2 3 4 5
STORYNO.
DRIFT IN MM
TH-STORY DRIFT FOR 0.5N/MM 2
0.5BFGSS15% 0.5BFGSS25%
0.5BFWSS15% 0.5BFWSS25%
0.5SFGSS15% 0.5SFGSS25%
0.5SFWSS15% 0.5SFWSS25%
0
1
2
3
4
5
6
7
8
9
10
0 1 2 3 4 5
STORYNO.
DRIFT
TH-STORY DRIFT FOR 1.06 N/MM 2
1.06BFGSS15% 1.06BFGSS25%
1.06BFWSS15% 1.06BFWSS25%
1.06SFGSS15% 1.06SFGSS25%
1.06SFWSS15% 1.06SFWSS25%
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 82
0.5BFWSS15% & 1.06BFWSS15% 0.5BFWSS25% & 1.06BFWSS25
0.5SFGSS25% 1.06SFGSS25%
0.5SFWSS15% 1.06SFWSS15%
0.5SFWSS25% 1.06SFWSS25%
From the analysis we can conclude that for the models with
Strut Frame has quite higher axial force on the ground
column as compared to Bare Frame. And it’s depending on
infill stiffness. The values are given in Table.5 for X
direction only in EQ-X.
6. CONCLUSION
In this paper sixteen models are prepared for Static Linear
analysis and Dynamic analysis (TH) results of models i.e.
without strut and with strut of infill wall with central outer
opening with 15% and 25% are compared. From this
analysis it can be concluded that diagonal strut will change
the seismic performance of RC building. Axial force in
column increased, story displacement and story drift are
decreased and base shear is increase with higher stiffness of
infill. If in the ground level at least periphery wall is provide
then soft story effect can be minimized. It can also be
concluded, the increase in the percentage of opening leads to
a decrease in the lateral stiffness.
7. ACKNOWLEDGEMNET
The author gratefully acknowledge the encouragement and
support given by the MS University of Baroda.
8. REFERENCES
[1] P. G. Asteris, 2003, M.ASCE, Lateral Stiffness of
Brick Masonry In filled Plane Frames, Journal of
Structural Engineering, Vol.129, No.8, August1,
2003.ASCE, ISSN0733-9445/2003/8-1071±1079.
[2] Panagiotis G. Asteris, Christis Z. Chrysostomou,
Ioannis P. Giannopoulos, and Eleni Smyrou,
Masonry Infilled Reinforced Concrete Frames With
Openings, III ECCOMAS Thematic Conference on
Computational Methods in Structural Dynamics and
Earthquake Engineering, M. Papadrakakis, M.
Fragiadakis, V. Plevris (eds.) ,Corfu, Greece, 26–28
May 2011
[3] Nehrp Guidelines for the Seismic Rehabilitation of
Buildings, FEDERAL EMERGENCY
MANAGEMENT AGENCY, FEMA 273 / October
1997, Chap. 7.
[4] Hemant B. Kaushik, Durgesh C. Rai, M.EERI, and
Sudhir K. Jain, M.EERI, Code Approaches to
Seismic Design of Masonry-Infilled Reinforced
Concrete Frames: AState-of-the-ArtReview,
Earthquake Spectra, Volume22, No.4, pages 961-
983, November2006; 2006, Earthquake Engineering
Research Institute.
[5] Diptesh Das and C.V.R. Murty, Brick masonry infills
in seismic design of RC framed building, The Indian
Concrete Journal,July 2004.
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 83
[6] Mohd Danish, Shoeb Masood, Zaid Mohammad, 2nd
International Conference on Emerging Trends in
Engineering & Technology, April 12-13, 2013.
[7] BIS, IS1905:1998 Code of practice structural use of
unreinforced masonry.
[8] I.S. 1905-1987, Code Of Practice For Structural Use
Of Unreinforced Masonry, Bureau of Indian
Standards, New Delhi
[9] Indian standard, Code of Practice for Plain and
Reinforced Concrete, IS 456: 2000, Bureau of Indian
Standards, New Delhi, India.
[10] Indian Standard, Criteria for earthquake resistant
design of structures, IS 1893(Part 1): 2002, Bureau of
Indian Standards, New Delhi, India.
[11] Murty, C.V.R., and Jain, S.K., 2000. Beneficial
influence of masonry infills on seismic performance
of RC frame buildings, Proceedings, 12th
World
Conference on Earthquake Engineering, New
Zealand, Paper No.1790.
BIOGRAPHIES
Jinyawala Mohammad Husenibhai
is a ME Dissertation student doing
his thesis under the guidance of
Dr.V. R. Patel from The M. S.
University of Baroda. He has done
his B.E. in civil engineering from
the Indore, RGPV Bhopal
university.
Dr. V. R. Patel is an assistant
professor in the Faculty of
Technology and Engineering, The
M. S. University of Baroda. He has
a broad experience in the field of
structure engineering. He has also
designed more than 2500 projects
which includes industrial, High rise
building.

More Related Content

PDF
A comparative study of the effect of infill walls on seismic performance of rei
DOCX
Solid Mechanics: Thin walled pressure vessel
PPT
Cable systems - form active structure system
PDF
COMPOSITE BEAMS.pdf
PDF
Two way slab
PPTX
SEISMIC EVALUATION
PDF
Civil structural engineering - Flat slab design
A comparative study of the effect of infill walls on seismic performance of rei
Solid Mechanics: Thin walled pressure vessel
Cable systems - form active structure system
COMPOSITE BEAMS.pdf
Two way slab
SEISMIC EVALUATION
Civil structural engineering - Flat slab design

What's hot (20)

PPTX
John Hancock Centre
PPT
PDF
ETABS manual - Seismic design of steel buildings according to Eurocode 3 & 8
PPTX
AITC Coupling Beam Design Procedure (20151106)
PDF
Cold-Formed-Steel Design And Construction ( Steel Structure )
PDF
10. design of mat foundation
PPT
footing
PDF
flat Slab
PPTX
Connection and Bracing
PPTX
CE 72.32 (January 2016 Semester) Lecture 5 - Preliminary Design and Sizing
PDF
Methods to Determine the Immediate or Elastic Settlement (الهبوط الفورى)
PPSX
Seismic Design Of Structures Project
PPT
Design of mat and combined footing
PPTX
CE 72.52 - Lecture 5 - Column Design
PPTX
Floor systems
DOCX
Design of isolated footing by ACI code
PDF
Prestressed concrete structures and its applications By Mukesh Singh Ghuraiya
PPTX
Seismic Analysis of regular & Irregular RCC frame structures
PDF
Design and analysis of reinforced concrete multistory commercial building usi...
PPTX
Hollow block and ribbed slabs
John Hancock Centre
ETABS manual - Seismic design of steel buildings according to Eurocode 3 & 8
AITC Coupling Beam Design Procedure (20151106)
Cold-Formed-Steel Design And Construction ( Steel Structure )
10. design of mat foundation
footing
flat Slab
Connection and Bracing
CE 72.32 (January 2016 Semester) Lecture 5 - Preliminary Design and Sizing
Methods to Determine the Immediate or Elastic Settlement (الهبوط الفورى)
Seismic Design Of Structures Project
Design of mat and combined footing
CE 72.52 - Lecture 5 - Column Design
Floor systems
Design of isolated footing by ACI code
Prestressed concrete structures and its applications By Mukesh Singh Ghuraiya
Seismic Analysis of regular & Irregular RCC frame structures
Design and analysis of reinforced concrete multistory commercial building usi...
Hollow block and ribbed slabs
Ad

Viewers also liked (20)

PPTX
Analysis of Confined Masonry part 2
PDF
Seismic evaluation of rc frame with brick masonry infill walls
PDF
Steel4 - A Versatile Uniaxial Material Model for Cyclic Nonlinear Analysis of...
PPTX
Analysis of Confined Masonry part 1
PPT
Intro to Confined Masonry
PDF
Code approaches to seismic design of masonry infiled rc frames
PDF
Gesture control algorithm for personal computers
PDF
Condition assessment of concrete with ndt – case
PDF
An algorithm for solving integer linear programming
PDF
Effective face feature for human identification
PDF
An enhanced approach for securing mobile agents from
PDF
A novel p q control algorithm for combined active
PDF
Detect and overcome the selfish problem in wifi network using energy sharing
PDF
Causes of delay in indian transportation
PDF
Redesign and thermal analysis of transfer mold tool
PDF
A survey on secured logging in the cloud
PDF
Effect of mobile phone and bts radiation on heart rate
PDF
Power balancing optimal selective forwarding
PDF
Performance comparison of row per slave and rows set
PDF
3 d mrf based video tracking in the compressed domain
Analysis of Confined Masonry part 2
Seismic evaluation of rc frame with brick masonry infill walls
Steel4 - A Versatile Uniaxial Material Model for Cyclic Nonlinear Analysis of...
Analysis of Confined Masonry part 1
Intro to Confined Masonry
Code approaches to seismic design of masonry infiled rc frames
Gesture control algorithm for personal computers
Condition assessment of concrete with ndt – case
An algorithm for solving integer linear programming
Effective face feature for human identification
An enhanced approach for securing mobile agents from
A novel p q control algorithm for combined active
Detect and overcome the selfish problem in wifi network using energy sharing
Causes of delay in indian transportation
Redesign and thermal analysis of transfer mold tool
A survey on secured logging in the cloud
Effect of mobile phone and bts radiation on heart rate
Power balancing optimal selective forwarding
Performance comparison of row per slave and rows set
3 d mrf based video tracking in the compressed domain
Ad

Similar to Analysis of rc frame with and without masonry infill wall with different stiffness with outer central opening (20)

PDF
Study on Behaviour of Rc Structure with Infill Walls Due to Seismic Loads
PDF
IRJET- Time History Analysis of Masonry Infilled RC Frames with Soft Stor...
PDF
Analysis of rc framed structures with central and partial openings in masonry...
PDF
Effect of infill walls on the seismic performance of the multistoried buildings
PDF
A Study on Seismic Response of Reinforced Concrete Framed Buildings with and ...
PDF
IRJET- Earthquake Analysis of RC Building with and without Infill Wall
PDF
Case study on slender multi storey rc building with brick infill
PDF
Seismic Response of RC Framed Buildings with Open Ground Storey
PDF
Anartificial Neural Network for Prediction of Seismic Behavior in RC Building...
PDF
LATERAL LOAD ANALYSIS OF SOFT STORY BUILDING AND IMPORTANCE OF MODELING MASON...
PDF
IRJET- A Review on R.C.C. Structure with Fully, Partially and without Infille...
PDF
Seismic Analysis on Bare Frame, Infilled Frame and Soft Story RC Framed Build...
PDF
Seismic evaluation of mutistorey building with soft storey
PDF
Seismic evaluation of mutistorey building with soft storey
PDF
COMPARISON BETWEEN THE EFFECT OF LINTEL AND LINTEL BAND ON THE GLOBAL PERFORM...
PDF
IRJET- Comparative Analysis of Square Shape RC Frame by Replacing Masonry fro...
PDF
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
PDF
Seismic evaluation of rc framed buildings with
PDF
Seismic evaluation of rc framed buildings with influence of masonry infill panel
PDF
IRJET- Earthquake Resistance Design of Open Ground Story Building
Study on Behaviour of Rc Structure with Infill Walls Due to Seismic Loads
IRJET- Time History Analysis of Masonry Infilled RC Frames with Soft Stor...
Analysis of rc framed structures with central and partial openings in masonry...
Effect of infill walls on the seismic performance of the multistoried buildings
A Study on Seismic Response of Reinforced Concrete Framed Buildings with and ...
IRJET- Earthquake Analysis of RC Building with and without Infill Wall
Case study on slender multi storey rc building with brick infill
Seismic Response of RC Framed Buildings with Open Ground Storey
Anartificial Neural Network for Prediction of Seismic Behavior in RC Building...
LATERAL LOAD ANALYSIS OF SOFT STORY BUILDING AND IMPORTANCE OF MODELING MASON...
IRJET- A Review on R.C.C. Structure with Fully, Partially and without Infille...
Seismic Analysis on Bare Frame, Infilled Frame and Soft Story RC Framed Build...
Seismic evaluation of mutistorey building with soft storey
Seismic evaluation of mutistorey building with soft storey
COMPARISON BETWEEN THE EFFECT OF LINTEL AND LINTEL BAND ON THE GLOBAL PERFORM...
IRJET- Comparative Analysis of Square Shape RC Frame by Replacing Masonry fro...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
Seismic evaluation of rc framed buildings with
Seismic evaluation of rc framed buildings with influence of masonry infill panel
IRJET- Earthquake Resistance Design of Open Ground Story Building

More from eSAT Publishing House (20)

PDF
Likely impacts of hudhud on the environment of visakhapatnam
PDF
Impact of flood disaster in a drought prone area – case study of alampur vill...
PDF
Hudhud cyclone – a severe disaster in visakhapatnam
PDF
Groundwater investigation using geophysical methods a case study of pydibhim...
PDF
Flood related disasters concerned to urban flooding in bangalore, india
PDF
Enhancing post disaster recovery by optimal infrastructure capacity building
PDF
Effect of lintel and lintel band on the global performance of reinforced conc...
PDF
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
PDF
Wind damage to buildings, infrastrucuture and landscape elements along the be...
PDF
Shear strength of rc deep beam panels – a review
PDF
Role of voluntary teams of professional engineers in dissater management – ex...
PDF
Risk analysis and environmental hazard management
PDF
Review study on performance of seismically tested repaired shear walls
PDF
Monitoring and assessment of air quality with reference to dust particles (pm...
PDF
Low cost wireless sensor networks and smartphone applications for disaster ma...
PDF
Coastal zones – seismic vulnerability an analysis from east coast of india
PDF
Can fracture mechanics predict damage due disaster of structures
PDF
Assessment of seismic susceptibility of rc buildings
PDF
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
PDF
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
Likely impacts of hudhud on the environment of visakhapatnam
Impact of flood disaster in a drought prone area – case study of alampur vill...
Hudhud cyclone – a severe disaster in visakhapatnam
Groundwater investigation using geophysical methods a case study of pydibhim...
Flood related disasters concerned to urban flooding in bangalore, india
Enhancing post disaster recovery by optimal infrastructure capacity building
Effect of lintel and lintel band on the global performance of reinforced conc...
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
Wind damage to buildings, infrastrucuture and landscape elements along the be...
Shear strength of rc deep beam panels – a review
Role of voluntary teams of professional engineers in dissater management – ex...
Risk analysis and environmental hazard management
Review study on performance of seismically tested repaired shear walls
Monitoring and assessment of air quality with reference to dust particles (pm...
Low cost wireless sensor networks and smartphone applications for disaster ma...
Coastal zones – seismic vulnerability an analysis from east coast of india
Can fracture mechanics predict damage due disaster of structures
Assessment of seismic susceptibility of rc buildings
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...

Recently uploaded (20)

PPTX
Foundation to blockchain - A guide to Blockchain Tech
PDF
Structs to JSON How Go Powers REST APIs.pdf
PPTX
Engineering Ethics, Safety and Environment [Autosaved] (1).pptx
PDF
Operating System & Kernel Study Guide-1 - converted.pdf
PDF
keyrequirementskkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk
PDF
Well-logging-methods_new................
PPTX
web development for engineering and engineering
PDF
The CXO Playbook 2025 – Future-Ready Strategies for C-Suite Leaders Cerebrai...
PPTX
Infosys Presentation by1.Riyan Bagwan 2.Samadhan Naiknavare 3.Gaurav Shinde 4...
PPTX
Sustainable Sites - Green Building Construction
PPTX
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
PPTX
Lesson 3_Tessellation.pptx finite Mathematics
PPTX
Welding lecture in detail for understanding
PDF
Embodied AI: Ushering in the Next Era of Intelligent Systems
PPTX
UNIT-1 - COAL BASED THERMAL POWER PLANTS
PPTX
FINAL REVIEW FOR COPD DIANOSIS FOR PULMONARY DISEASE.pptx
PDF
Model Code of Practice - Construction Work - 21102022 .pdf
DOCX
ASol_English-Language-Literature-Set-1-27-02-2023-converted.docx
PDF
Mohammad Mahdi Farshadian CV - Prospective PhD Student 2026
PPTX
Strings in CPP - Strings in C++ are sequences of characters used to store and...
Foundation to blockchain - A guide to Blockchain Tech
Structs to JSON How Go Powers REST APIs.pdf
Engineering Ethics, Safety and Environment [Autosaved] (1).pptx
Operating System & Kernel Study Guide-1 - converted.pdf
keyrequirementskkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk
Well-logging-methods_new................
web development for engineering and engineering
The CXO Playbook 2025 – Future-Ready Strategies for C-Suite Leaders Cerebrai...
Infosys Presentation by1.Riyan Bagwan 2.Samadhan Naiknavare 3.Gaurav Shinde 4...
Sustainable Sites - Green Building Construction
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
Lesson 3_Tessellation.pptx finite Mathematics
Welding lecture in detail for understanding
Embodied AI: Ushering in the Next Era of Intelligent Systems
UNIT-1 - COAL BASED THERMAL POWER PLANTS
FINAL REVIEW FOR COPD DIANOSIS FOR PULMONARY DISEASE.pptx
Model Code of Practice - Construction Work - 21102022 .pdf
ASol_English-Language-Literature-Set-1-27-02-2023-converted.docx
Mohammad Mahdi Farshadian CV - Prospective PhD Student 2026
Strings in CPP - Strings in C++ are sequences of characters used to store and...

Analysis of rc frame with and without masonry infill wall with different stiffness with outer central opening

  • 1. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 76 ANALYSIS OF RC FRAME WITH AND WITHOUT MASONRY INFILL WALL WITH DIFFERENT STIFFNESS WITH OUTER CENTRAL OPENING Mohammad H. Jinya1 , V. R. Patel2 1 P.G. Student, Applied Mechanics Department, M. S. University of Baroda, Vadodara, India. 2 Assistant Professor, Applied Mechanics Department, M. S. University of Baroda, Vadodara, India. Abstract In reinforced concrete frame building, masonry wall are generally used in as infills and specified by architects as partitions in such a way that they do not contribute to the vertical gravity load-bearing capacity of the structure. Infill walls protect the inside of the buildings from the environment hazards and create separation insides. In addition to this infills have a considerable strength and stiffness and they have significant effect on the seismic response of the structural systems. Mostly two common structural damages observed caused by masonry infill walls in earthquakes i.e soft stories and short columns. In office or residential building outer side central opening are used. In this case central opening are provided in periphery wall with different percentage i.e. 15% and 25% and brick compressive strength are used as per IS : 1905-1987 i.e. 5.0 and 12.5 N/mm2 and Brick Masonry strength is 0.50 and 1.06N/mm2 . In ETABS software G+9 R.C.C framed building models has been prepared, Seismic coefficient method(SCM) and time-history(TH) has been performed for analysis as per IS 1893:2002. Story displacement, base shear, story drift, axial force with and without soft story considering effect of infill walls with different percentage of opening are the parameters considered in this study. For Macro model, Equivalent diagonal strut (EDS) method is used to find out width of strut using FEMA approach method. The results of bare frame, soft story and infill wall panel are discussed and conclusions are made in this studies. Key Words: Base shear, Displacement, Equivalent Diagonal Strut, Storey Drift, Soft storey. --------------------------------------------------------------------***---------------------------------------------------------------------- 1. INTRODUCTION In RC frame brick walls is just architectural point of view and to make partition and other aspect. In multistory buildings, the ordinarily occurring vertical loads i.e. dead or alive, do not cause much of a effects, but the lateral loads due to wind or earthquake tremors are a matter of great concern and need special consideration in the design of buildings. These lateral forces can produce the critical stress in a structure, set up undesirable vibrations, and in addition, cause lateral sway of the structure which can reach a stage of discomfort to the occupants. In many countries situated in seismic regions, reinforced concrete frames are infilled fully or partially by brick masonry panels with or without openings. Although the infill panels significantly enhance both the stiffness and strength of the frame, their contribution is often not taken into account because of the lack of knowledge of the composite behavior of the frame and the infill. During the elastic response phase, the presence of brick infill walls increases in plane lateral stiffness of the structure and reduced its fundamental period, and as a result leads to larger shear forces. In residential building RC frame structure are infill by brick panels on all four sides and resisting the lateral earthquake loads on building. By experimentally it has been shown that brick walls have high initial lateral stiffness (Moghaddam and Dowling 1987, Drysdale et al. 1999, Paulay and Priestley 1992,). Hence masonry infills in RC frames different lateral load transfer mechanism of the structure from predominant frame action to predominant truss action (Murty and Jain 2000). Shown in Figure 1 below. Thus it is responsible for increase in axial forces in the RC frame. Fig -1: Change in lateral-load transfer mechanism due to masonry infill (Murty and Jain 2000)
  • 2. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 77 2. LITERATURE REVIEW From several research paper studies it shows that Equivalent diagonal strut method is used for modeling the brick infill wall to easy represent the effect of inplane during lateral load and its equations for Equivalent diagonal strut width for full infill given by various researchers are, In 1961 Holmes, w = dz/3 where, dz = Diagonal length of infill panel In 1962 Equivalent diagonal strut according to Smith, here and In 1969 Smith and Carter, where In 1971 Mainstone, w = 0.175dz (λhH’)-0.4 In 1984 Liaw and Kwan, w = (0.95Hcosθ)/ √λhH’ In 1992 Paulay & Priestley, w = dz/4 3. RESEARCH OBJECTIVES The main objective of this paper is to simplify the analysis concept of the building industry. And also carry out the effect of brick masonry infilled walls for the static linear analysis and Time history analysis of the R.C.C high rise building with single diagonal strut approach as per IS 1893:2002 and IS 456:2000. The result would be carried out and compare for G+9 story R.C.C. building. 4. METHOD OF ANALYSIS OF THE BRICK INFILL WALL 4.1 Data Taken Table -1: Data for Building 4.2 Types of Model Table -2: Types of Model ID (The First value indicates masonry comp. stress, N/mm2 ) Description 0.5BFGSS15% Bare frame ground soft story with 15% outer central opening 0.5SFGSS15% Strut frame ground soft story with 15% outer central opening 1.06BFGSS15% Bare frame ground soft story with 15% outer central opening 1.06SFGSS15% Strut frame ground soft story with 15% outer central opening 0.5BFGSS25% Bare frame ground soft story with 25% outer central opening 0.5SFGSS25% Strut frame ground soft story with 25% outer central opening 1.06BFGSS25% Bare frame ground soft story with 25% outer central opening Story = G+8 4x3 bay Ground floor height = 3.0m Typ. story height= 2.9m Basement height= 3.0m Beam= 230 x 450 mm Column= 500 x 500mm Spacing of frame X direction= 3m Spacing of frame Y direction= 3m Live load= 1.5 kn/m2 for terrace 3.0 kn/m2 for typ floor Dead load= 2.0 kn/m2 for terrace 1.0 kn/m2 for typ floor Response Reduction Factor, R= 3 for SMRF Importance factor, I= 1.0 Type of soil= Medium Damping of structure= 5% Grade of concrete= M30 Steel= Fe 415 Density of concrete= 25 kn/m3 Density of brick wall= 20 kn/m3 Modulus of elasticity of concrete, Ec= 27.386 x 106 kn/m2 Modulus of elasticity masonry, Em= 1)0.275 x 106 kn/m2 2)0.583 x 106 kn/m2 Thick. of outer Brick wall= 115 mm Thick. of inner Brick wall= 115 mm Thick. of slab= 125mm Poisson ratio of concrete= 0.2 Poisson ratio of brick wall= 0.17 Seismic zone= V Z = 0.36 Time history Bhuj_Ahmedabad
  • 3. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 78 1.06SFGSS25% Strut frame ground soft story with 25% outer central opening 0.5BFWSS15% Bare frame without soft story with 15% outer central opening 0.5SFWSS15% Strut frame without soft story with 15% outer central opening 1.06BFWSS15% Bare frame without soft story with 15% outer central opening 1.06SFWSS15% Strut frame without soft story with 15% outer central opening 0.5BFWSS25% Bare frame without soft story with 25% outer central opening 0.5SFWSS25% Strut frame without soft story with 25% outer central opening 1.06BFWSS25% Bare frame without soft story with 25% outer central opening 1.06SFWSS25% Strut frame without soft story with 25% outer central opening 4.3 Modelling of Brick Infill Wall Fig -2: Plan 4.4 FEMA Approach Equivalent diagonal strut method is used for modeling the brick infill wall according to FEMA273.The infill frame in this model was assumed as an equivalent diagonal strut with frame the pin joint(hinge joint) at the corners of the RC frame(See Fig.5). In this method the brick infill wall replaced by diagonal strut. The frame is analyzed as truss element. The equivalent diagonal strut width is given as: w = 0.175(λ1hcol )-0.4 rinf………………eqn 1 Where, λ1 = Fig- 5 Diagonal strut with pinned joint And hcol =Column height between centerlines of beams,m hinf = Height of infill panel, m Efe =Expected modulus of elasticity of frame material,kn/m2 Eme =Expected modulus of elasticity of infill material, kn/m2 Icol = Moment of inertia of column, m4 Linf = Length of infill panel, m rinf = Diagonal length of infill panel, m tinf =Thickness of infill panel and equivalent strut, m θ =Angle whose tangent is the infill height-to-length aspect ratio, radians λ1 = Coefficient used to determine equivalent width of infill strut BEA M COLUMN EDS Hinge Fig- 3 3D View of Bare Frame Fig- 4 3D View of Strut Frame BEAM COLUMN
  • 4. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 79 4.5 Strut Reduction Factor Reduction factor λ=1-2αw 0.54 +αw 1.14 The above coefficient (ʎ) could be used to find the equivalent width of a strut for the case of an infill with opening by multiplying the results of Eqns. 1 above for central opening. 4.6 Modulus of elasticity of brick masonry In lieu of prism tests, values for the modulus of elasticity of masonry in compression shall be taken as, 550 times the expected masonry compressive strength, fme. i) Compressive strength, fme = 0.5MPa (IS 1905:1998, Table-8) Em= 550 x fme = 550 x 0.5 x 103 = 0.275 x 106 kn/m2 ii) Compressive strength, fme = 1.06MPa (IS 1905:1998, Table-8) Em= 550 x fme = 550 x 1.06 x 103 = 0.583 x 106 kn/m2 4.7 Fundamental Natural Period of Vibration, (Ts) Ts= 0.09h/sqrt(d) Tx = 0.8314 s, Ty = 0.96 s Where, h = Height of building, in m d = Base dimension of the building at the plinth level, in m 4.8 Average Response Acceleration Coefficient (Sa/g)x = 1.36/T = 1.635826 (Sa/g)y = 1.36/T = 1.416667 5. RESULT AND DISCUSSION 5.1 Base Shear The design base shear Vb as per IS: 1893 shall be calculated by following formula, Vb = Ah x W Where, Ahx,y = ZIS/2RG Ahx = 0.069949 Ahy = 0.049461 Table -3: Base shear BASE SHEAR IN X-DIRECTION(KN) ID SCM TH 0.5BFGSS15% 1549.31 1222.84 0.5SFGSS15% 1549.31 1178.59 1.06BFGSS15% 1549.31 1222.84 1.06SFGSS15% 1549.31 1379.87 0.5BFGSS25% 1519.63 1196.86 0.5SFGSS25% 1519.63 1155.00 1.06BFGSS25% 1519.63 1196.86 1.06SFGSS25% 1519.63 1348.81 0.5BFWSS15% 1595.76 1233.61 0.5SFWSS15% 1595.77 1202.23 1.06BFWSS15% 1595.76 1233.61 1.06SFWSS15% 1595.77 1693.92 0.5BFWSS25% 1566.01 1208.23 0.5SFWSS25% 1566.01 1186.65 1.06BFWSS25% 1566.01 1208.23 1.06SFWSS25% 1566.01 1652.86 Chart -1: Base shear at base in X Direction (Kn) We can conclude from this analysis that with increase in stiffness of infill wall base shear of building also increase thus stiffness of wall is should be minimum. 5.2 Displacement 0 0.2 0.4 0.6 0.8 1 1.2 0 50 100 150 Reductionfactorλ Opening % 0 500 1000 1500 2000 0.5BFGSS15% 0.5SFGSS15% 1.06BFGSS15% 1.06SFGSS15% 0.5BFGSS25% 0.5SFGSS25% 1.06BFGSS25% 1.06SFGSS25% 0.5BFWSS15% 0.5SFWSS15% 1.06BFWSS15% 1.06SFWSS15% 0.5BFWSS25% 0.5SFWSS25% 1.06BFWSS25% 1.06SFWSS25% BASE SHEAR IN X-DIR. SCM TH
  • 5. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 80 Table -4: Displacement at the top level DISPLACEMENT AT ROOF LEVEL IN MM SR NO. ID SCM TH 1 0.5BFGSS15% 51.2 31.55 2 0.5SFGSS15% 44.59 27.37 3 1.06BFGSS15% 51.2 31.55 4 1.06SFGSS15% 39.42 31.21 5 0.5BFGSS25% 50.28 31.45 6 0.5SFGSS25% 44.34 27.64 7 1.06BFGSS25% 50.28 31.45 8 1.06SFGSS25% 39.56 31.19 9 0.5BFWSS15% 52.7 31.69 10 0.5SFWSS15% 44.74 28.95 11 1.06BFWSS15% 52.7 31.69 12 1.06SFWSS15% 38.63 32.58 13 0.5BFWSS25% 51.78 31.6 14 0.5SFWSS25% 44.52 29.19 15 1.06BFWSS25% 51.78 31.6 16 1.06SFWSS25% 38.81 32.61 Chart -2: Displacement at the top in X Direction The displacement in X direction for diff. models are shown in Graph 2. From graph it can be concluded that with increase in stiffness of infill wall displacement of building decreased by 12% to 25 %( see Table 4) in Static and Dynamic analysis. 5.3 Story Drift The drift value for SCM and TH analysis results are shown in followings different chart in mm (see Chart 3 to 6). Chart-3: Story Drift for SCM in X direction (0.5) Chart-4: Story Drift for SCM in X direction (1.06) 0 10 20 30 40 50 60 0.5BFGSS15% 0.5SFGSS15% 1.06BFGSS15% 1.06SFGSS15% 0.5BFGSS25% 0.5SFGSS25% 1.06BFGSS25% 1.06SFGSS25% 0.5BFWSS15% 0.5SFWSS15% 1.06BFWSS15% 1.06SFWSS15% 0.5BFWSS25% 0.5SFWSS25% 1.06BFWSS25% 1.06SFWSS25% DISPLACEMENT IN MM X-DIR. SCM TH 0 1 2 3 4 5 6 7 8 9 10 0 2 4 6 8 STORYNO. DRIFT IN MM SCM-STORY DRIFT FOR 0.5N/MM 2 0.5BFGSS15% 0.5BFGSS25% 0.5BFWSS15% 0.5BFWSS25% 0.5SFGSS15% 0.5SFGSS25% 0.5SFWSS15% 0.5SFWSS25% 0 1 2 3 4 5 6 7 8 9 10 0 2 4 6 8 STORYNO. DRIFT SCM-STORY DRIFT FOR 1.06 N/MM 2 1.06BFGSS15% 1.06BFGSS25% 1.06BFWSS15% 1.06BFWSS25% 1.06SFGSS15% 1.06SFGSS25% 1.06SFWSS15% 1.06SFWSS25%
  • 6. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 81 Chart-5: Story Drift for TH in X direction (0.5) Chart-6: Story Drift for TH in X direction (1.06) The drift value has a particular importance of serviceability requirement. According to Indian seismic code IS 1893 Part- 1 :2002, The story drift in any story due to the minimum specified design lateral force, with partial load factor of 1.0, shall not exceed 0.004 * h, where h = story height. In building with strut, Story drift is less as compared to without considering strut type building in both direction, i.e. and Y.(See Chart 3 to 6). All story drift are found to be within permissible limit i.e. 1.2 cm. 5.4 Axial Force The maximum axial force in the column are as shown in following, Table 5: Maximum Axial Force (kn) on column at Base in EQ-X 0.5BFGSS15% & 1.06BFGSS15% 0.5BFGSS25% & 1.06BFGSS25% 0.5SFGSS15% 1.06SFGSS15% 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 STORYNO. DRIFT IN MM TH-STORY DRIFT FOR 0.5N/MM 2 0.5BFGSS15% 0.5BFGSS25% 0.5BFWSS15% 0.5BFWSS25% 0.5SFGSS15% 0.5SFGSS25% 0.5SFWSS15% 0.5SFWSS25% 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 STORYNO. DRIFT TH-STORY DRIFT FOR 1.06 N/MM 2 1.06BFGSS15% 1.06BFGSS25% 1.06BFWSS15% 1.06BFWSS25% 1.06SFGSS15% 1.06SFGSS25% 1.06SFWSS15% 1.06SFWSS25%
  • 7. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 82 0.5BFWSS15% & 1.06BFWSS15% 0.5BFWSS25% & 1.06BFWSS25 0.5SFGSS25% 1.06SFGSS25% 0.5SFWSS15% 1.06SFWSS15% 0.5SFWSS25% 1.06SFWSS25% From the analysis we can conclude that for the models with Strut Frame has quite higher axial force on the ground column as compared to Bare Frame. And it’s depending on infill stiffness. The values are given in Table.5 for X direction only in EQ-X. 6. CONCLUSION In this paper sixteen models are prepared for Static Linear analysis and Dynamic analysis (TH) results of models i.e. without strut and with strut of infill wall with central outer opening with 15% and 25% are compared. From this analysis it can be concluded that diagonal strut will change the seismic performance of RC building. Axial force in column increased, story displacement and story drift are decreased and base shear is increase with higher stiffness of infill. If in the ground level at least periphery wall is provide then soft story effect can be minimized. It can also be concluded, the increase in the percentage of opening leads to a decrease in the lateral stiffness. 7. ACKNOWLEDGEMNET The author gratefully acknowledge the encouragement and support given by the MS University of Baroda. 8. REFERENCES [1] P. G. Asteris, 2003, M.ASCE, Lateral Stiffness of Brick Masonry In filled Plane Frames, Journal of Structural Engineering, Vol.129, No.8, August1, 2003.ASCE, ISSN0733-9445/2003/8-1071±1079. [2] Panagiotis G. Asteris, Christis Z. Chrysostomou, Ioannis P. Giannopoulos, and Eleni Smyrou, Masonry Infilled Reinforced Concrete Frames With Openings, III ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering, M. Papadrakakis, M. Fragiadakis, V. Plevris (eds.) ,Corfu, Greece, 26–28 May 2011 [3] Nehrp Guidelines for the Seismic Rehabilitation of Buildings, FEDERAL EMERGENCY MANAGEMENT AGENCY, FEMA 273 / October 1997, Chap. 7. [4] Hemant B. Kaushik, Durgesh C. Rai, M.EERI, and Sudhir K. Jain, M.EERI, Code Approaches to Seismic Design of Masonry-Infilled Reinforced Concrete Frames: AState-of-the-ArtReview, Earthquake Spectra, Volume22, No.4, pages 961- 983, November2006; 2006, Earthquake Engineering Research Institute. [5] Diptesh Das and C.V.R. Murty, Brick masonry infills in seismic design of RC framed building, The Indian Concrete Journal,July 2004.
  • 8. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 03 Issue: 06| Jun-2014, Available @ http://www.ijret.org 83 [6] Mohd Danish, Shoeb Masood, Zaid Mohammad, 2nd International Conference on Emerging Trends in Engineering & Technology, April 12-13, 2013. [7] BIS, IS1905:1998 Code of practice structural use of unreinforced masonry. [8] I.S. 1905-1987, Code Of Practice For Structural Use Of Unreinforced Masonry, Bureau of Indian Standards, New Delhi [9] Indian standard, Code of Practice for Plain and Reinforced Concrete, IS 456: 2000, Bureau of Indian Standards, New Delhi, India. [10] Indian Standard, Criteria for earthquake resistant design of structures, IS 1893(Part 1): 2002, Bureau of Indian Standards, New Delhi, India. [11] Murty, C.V.R., and Jain, S.K., 2000. Beneficial influence of masonry infills on seismic performance of RC frame buildings, Proceedings, 12th World Conference on Earthquake Engineering, New Zealand, Paper No.1790. BIOGRAPHIES Jinyawala Mohammad Husenibhai is a ME Dissertation student doing his thesis under the guidance of Dr.V. R. Patel from The M. S. University of Baroda. He has done his B.E. in civil engineering from the Indore, RGPV Bhopal university. Dr. V. R. Patel is an assistant professor in the Faculty of Technology and Engineering, The M. S. University of Baroda. He has a broad experience in the field of structure engineering. He has also designed more than 2500 projects which includes industrial, High rise building.