ASTM-E709
ADOPTION NOTICE
ASTM-E709, "EXAMINATION, MAGNETIC PARTICLE", was adopted on
09-JAN-80 for use by the Department of Defense (DoD). Proposed
changes by DoD activities must be submitted to the DoD Adopting
Activity: Army Research Laboratory Weapons and Materials Research
Directorate, Attn: AMSRL-WM-M, Aberdeen Proving Ground, MD
21005-5069. Copies of this document may be purchased from the
American Society for Testing and Materials 100 Barr Harbor Drive
West Conshohocken, Pennsylvania, United States, 19428-2959.
http://www.astm.org/
____________________
Custodians: Adopting Activity:
Army - MR
Army - MR
Navy - AS
Air Force - 11
Reviewer Activities:
Army - AR, AT, AV
Navy - SH
DLA - IS
AREA NDTI
DISTRIBUTION STATEMENT A: Approved for public release; distribution
is unlimited.
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
Designation: E 709 – 01 An American National Standard
Standard Guide for
Magnetic Particle Examination1
This standard is issued under the fixed designation E 709; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope
1.1 This guide2
describes techniques for both dry and wet
magnetic particle examination, a nondestructive method for
detecting cracks and other discontinuities at or near the surface
in ferromagnetic materials. Magnetic particle examination may
be applied to raw material, semifinished material (billets,
blooms, castings, and forgings), finished material and welds,
regardless of heat treatment or lack thereof. It is useful for
preventive maintenance examination.
1.1.1 This guide is intended as a reference to aid in the
preparation of specifications/standards, procedures and tech-
niques.
1.2 This guide is also a reference that may be used as
follows:
1.2.1 To establish a means by which magnetic particle
examination, procedures recommended or required by indi-
vidual organizations, can be reviewed to evaluate their appli-
cability and completeness.
1.2.2 To aid in the organization of the facilities and person-
nel concerned in magnetic particle examination.
1.2.3 To aid in the preparation of procedures dealing with
the examination of materials and parts. This guide describes
magnetic particle examination techniques that are recom-
mended for a great variety of sizes and shapes of ferromagnetic
materials and widely varying examination requirements. Since
there are many acceptable differences in both procedure and
technique, the explicit requirements should be covered by a
written procedure (see Section 21).
1.3 This guide does not indicate, suggest, or specify accep-
tance standards for parts/pieces examined by these techniques.
It should be pointed out, however, that after indications have
been produced, they must be interpreted or classified and then
evaluated. For this purpose there should be a separate code,
specification, or a specific agreement to define the type, size,
location, degree of alignment and spacing, area concentration,
and orientation of indications that are unacceptable in a specific
part versus those which need not be removed before part
acceptance. Conditions where rework or repair are not permit-
ted should be specified.
1.4 This guide describes the use of the following magnetic
particle method techniques.
1.4.1 Dry magnetic powder (see 8.4),
1.4.2 Wet magnetic particle (see 8.5),
1.4.3 Magnetic slurry/paint magnetic particle (see 8.5.8),
and
1.4.4 Polymer magnetic particle (see 8.5.8).
1.5 Personnel Qualification—Personnel performing exami-
nations in accordance with this guide shall be qualified and
certified in accordance with ASNT Recommended Practice No.
SNT-TC-1A, ANSI/ASNT Standard CP-189, NAS 410, or as
specified in the contract or purchase order.
1.6 Nondestructive Testing Agency—If a nondestructive
testing agency as described in Practice E 543 is used to
perform the examination, the testing agency shall meet the
requirements of Practice E 543.
1.7 Table of Contents:
SECTION
Scope 1
Scope Description 1.1
A Reference Document 1.2
Acceptance Standards for Parts not Covered 1.3
Magnetic Particle Method Techniques 1.4
Personnel Qualifications 1.5
Nondestructive Testing Agency 1.6
Table of Contents 1.7
SI Units 1.8
Safety Caveat 1.9
Referenced Documents 2
ASTM Standards 2.1
SAE Documents 2.2
ASNT Documents 2.3
U.S. Government Documents 2.4
Definitions 3
Summary of Guide 4
Principle 4.1
Method 4.2
Magnetization 4.3
Types of Magnetic Particle and Their Use 4.4
Evaluation of Indications 4.5
Typical Magnetic Particle Indications 4.6
Significance and Use 5
Equipment 6
Types 6.1
1
This guide is under the jurisdiction of ASTM Committee E07 on Nondestruc-
tive Testing and is the direct responsibility of Subcommittee E07.03 on Magnetic
Particle and Penetrant Testing.
Current edition approved July 10, 2001. Published September 2001. Originally
published as E 709 – 80. Last previous edition E 709 – 95.
2
For ASME Boiler and Pressure Vessel Code Applications see related Guide
SE-709 in Section II of that Code.
1
Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
SECTION
Portability 6.2
Yokes 6.3
Prods 6.4
Black Light 6.5
Equipment Verification 6.6
Examination Area 7
Light Intensity for Examination 7.1
Housekeeping 7.2
Magnetic Particle Materials 8
Particle Types 8.2
Particle Characteristics 8.3
Dry Particles 8.4
Wet Particle Systems 8.5
Part Preparation 9
General 9.1
Cleaning Examination Surface 9.2
Sequence of Operations 10
Sequencing Particle Application and Establishing Mag-
netic Flux Field
10.1
Types of Magnetizing Currents 11
Basic Current Types 11.1
Part Magnetization Techniques 12
Examination Coverage 12.1
Direct and Indirect Magnetization 12.2
Choosing a Magnetization Technique 12.3
Direction of Magnetic Fields 13
Discontinuity Orientation vs Magnetic Field Direction 13.1
Circular Magnetization 13.2
Torodial Magnetization 13.3
Longitudinal Magnetization 13.4
Multidirectional Magnetization 13.5
Magnetic Field Strength 14
Magnetizing Field Strengths 14.1
Establishing Field Strengths 14.2
Guidelines for Establishing Magnetic Fields 14.3
Application of Dry and Wet Magnetic Particles 15
Dry Magnetic Particles 15.1
Wet Particles Applications 15.2
Magnetic Slurry/Paint 15.3
Magnetic Polymers 15.4
Interpretation of Indications 16
Valid Indications 16.1
Recording of Indications 17
Means of Recording 17.1
Accompanying Information 17.2
Demagnetization 18
Applicability 18.1
Demagnetization Methods 18.2
Extent of Demagnetization 18.3
Post Examination Cleaning 19
Particle Removal 19.1
Means of Particle Removal 19.2
Evaluation of System Performance/Sensitivity 20
Contributor Factors 20.1
Maintenance and Calibration of Equipment 20.2
Equipment Checks 20.3
Examination Area Light Level Control 20.4
Dry Particle Quality Control Tests 20.5
Wet Particle Quality Control Tests 20.6
Bath Characteristics Control 20.7
Verifying System Performance 20.8
Procedure and Report 21
Written Procedure 21.1
Written Reports 21.2
Acceptance Standards 22
Safety 23
SECTION
Precision and Bias 24
Keywords 25
Annex AnnexA1
Appendix X1. Appendix
X1
Appendix X2. Appendix
X2
1.8 The numerical values shown in inch-pound units are to
be regarded as the standard. SI units are provided for informa-
tion only.
1.9 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
A 275/A 275M Test Method for Magnetic Particle Exami-
nation of Steel Forgings3
A 456/A 456M Specification for Magnetic Particle Exami-
nation of Large Crankshaft3
D 93 Test Methods for Flash Point by Pensky-Martens
Closed Tester4
D 129 Test Method for Sulfur in Petroleum Products (Gen-
eral Bomb Method)4
D 445 Test Method for Kinematic Viscosity of Transparent
and Opaque Liquids (and the Calculation of Dynamic
Viscosity)4
D 808 Test Method for Chlorine in New and Used Petro-
leum Products (Bomb Method)4
D 1966 Test Method for Foots in Raw Linseed Oil Gravi-
metric Method5
E 165 Test Method for Liquid Penetrant Examination6
E 543 Practice for Agencies Performing Nondestructive
Testing6
E 1316 Terminology for Nondestructive Examinations6
E 1444 Practice for Magnetic Particle Examination6
2.2 Society of Automotive Engineers (SAE): Aerospace
Materials Specifications:7
AMS 2300 Premium Aircraft Quality Steel Cleanliness
Magnetic Particle Inspection Procedure
AMS 2301 Aircraft Quality Steel Cleanliness Magnetic Par-
ticle Inspection Procedure
AMS 2303 Aircraft Quality Steel Cleanliness Martensitic
Corrosion Resistant Steels Magnetic Particle Inspection
Procedure
AMS 2641 Vehicle Magnetic Particle Inspection
AMS 3040 Magnetic Particles, Non-fluorescent, Dry
Method
AMS 3041 Magnetic Particles, Non-fluorescent, Wet
Method, Oil Vehicle, Ready to Use
3
Annual Book of ASTM Standards, Vol 01.05.
4
Annual Book of ASTM Standards, Vol 05.01.
5
Annual Book of ASTM Standards, Vol 06.03.
6
Annual Book of ASTM Standards, Vol 03.03.
7
Available from Society of Automotive Engineers, 400 Commonwealth Drive,
Warrendale, PA 15096.
E 709
2
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
AMS 3042 Magnetic Particles, Non-fluorescent, Wet
Method, Dry Powder
AMS 3043 Magnetic Particles, Non-fluorescent, Oil Ve-
hicle, Aerosol Packaged
AMS 3044 Magnetic Particles, Fluorescent, Wet Method,
Dry Powder
AMS 3045 Magnetic Particles, Non-fluorescent, Wet
Method, Oil Vehicle, Ready to Use
AMS 3046 Magnetic Particles, Non-fluorescent, Wet
Method, Oil Vehicle, Aerosol Packaged
AMS 5062 Steel, Low Carbon Bars, Forgings, Tubing,
Sheet, Strip, and Plate 0.25 Carbon, Maximum
AMS 5355 Investment Castings
AMS-I-83387 Inspection Process, Magnetic Rubber
AS 4792 Water Conditioning Agents for Aqueous Magnetic
Particle Inspection
AS 5282 Tool Steel Ring Standard for Magnetic Particle
Inspection
AS 5371 Reference Standards Notched Shims for Magnetic
Particle Inspection
2.3 American Society for Nondestructive Testing:8
SNT-TC-1A Recommended Practice Magnetic Particle
Method
CP-189 ASNT Qualification and Certification of Nonde-
structive Testing Personnel
2.4 Federal Standards:9
A-A-59230 Fluid, Magnetic Particle Inspection, Suspension
FED-STD 313 Material Safety Data Sheets Preparation and
the Submission of
2.5 OSHA Document:10
29CFR 1910.1200 Hazard Communication
2.6 AIA Documents:
NAS 410 Nondestructive Testing Personnel Qualification
and Certification
3. Terminology
3.1 For definitions of terms used in the practice, refer to
Terminology E 1316
4. Summary of Guide
4.1 Principle—The magnetic particle method is based on
the principle that magnetic field lines when present in a
ferromagnetic material, will be distorted by a change in
material continuity, such as a sharp dimensional change or a
discontinuity. If the discontinuity is open to or close to the
surface of a magnetized material, flux lines will be distorted at
the surface, a condition termed as “flux leakage.” When fine
magnetic particles are distributed over the area of the discon-
tinuity while the flux leakage exists, they will be held in place
and the accumulation of particles will be visible under the
proper lighting conditions. While there are variations in the
magnetic particle method, they all are dependent on this
principle, that magnetic particles will be retained at the
locations of magnetic flux leakage.
4.2 Method—While this practice permits and describes
many variables in equipment, materials, and procedures, there
are three steps essential to the method:
4.2.1 The part must be magnetized.
4.2.2 Magnetic particles of the type designated in the
contract/purchase order/specification must be applied while the
part is magnetized.
4.2.3 Any accumulation of magnetic particles must be
observed, interpreted, and evaluated.
4.3 Magnetization:
4.3.1 Ways to Magnetize—A ferromagnetic material can be
magnetized either by passing an electric current through the
material or by placing the material within a magnetic field
originated by an external source. The entire mass or a portion
of the mass can be magnetized as dictated by size and
equipment capacity or need. As previously noted, the discon-
tinuity must interrupt the normal path of the magnetic field
lines. If a discontinuity is open to the surface, the flux leakage
will be at the maximum for that particular discontinuity. When
that same discontinuity is below the surface, flux leakage
evident on the surface will be less. Practically, discontinuities
must be open to the surface, to create sufficient flux leakage to
accumulate magnetic particles.
4.3.2 Field Direction—If a discontinuity is oriented parallel
to the magnetic field lines, it may be essentially undetectable.
Therefore, since discontinuities may occur in any orientation, it
may be necessary to magnetize the part or area of interest twice
or more sequentially in different directions by the same method
or a combination of methods (see Section 13) to induce
magnetic field lines in a suitable direction in order to perform
an adequate examination.
4.3.3 Field Strength—The magnetic field must be of suffi-
cient strength to indicate those discontinuities which are
unacceptable, yet must not be so strong that an excess of
particles is accumulated locally thereby masking relevant
indications (see Section 14).
4.4 Types of Magnetic Particles and Their Use—There are
various types of magnetic particles available for use in mag-
netic particle examination. They are available as dry powders
(fluorescent and nonfluorescent) ready for use as supplied (see
8.4), powder concentrates (fluorescent and nonfluorescent) for
dispersion in water or suspending light petroleum distillates
(see 8.5), magnetic slurries/paints (see 8.5.7), and magnetic
polymer dispersions (see 8.5.8).
4.5 Evaluation of Indications—When the material to be
examined has been properly magnetized, the magnetic particles
have been properly applied, and the excess particles properly
removed, there will be accumulations of magnetic particles at
the points of flux leakage. These accumulations show the
distortion of the magnetic field and are called indications.
Without disturbing the particles, the indications must be
examined, classified, interpreted as to cause, compared with
the acceptance standards, and a decision made concerning the
disposition of the material that contains the indication.
4.6 Typical Magnetic Particle Indications:
4.6.1 Surface Discontinuities—Surface discontinuities, with
8
Available from American Society for Nondestructive Testing, 1711 Arlingate
Plaza, P.O. Box 28518, Columbus, OH 43228-0518.
9
Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700
Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
10
Available from Occupational Safety and Health Review Commission, 1825 K
Street, N.W., Washington, DC 20006.
E 709
3
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
few exceptions, produce sharp, distinct patterns (see Annex
A1).
4.6.2 Near-surface discontinuities—Near-surface disconti-
nuities produce less distinct indications than those open to the
surface. The patterns are broad, rather than sharp, and the
particles are less tightly held (see Annex A1).
5. Significance and Use
5.1 The magnetic particle method of nondestructive exami-
nation indicates the presence of surface and near-surface
discontinuities in materials that can be magnetized (ferromag-
netic). This method can be used for production examination of
parts/components or structures and for field applications where
portability of equipment and accessibility to the area to be
examined are factors. The ability of the method to find small
discontinuities can be enhanced by using fluorescent particles
suspended in a suitable vehicle and by introducing a magnetic
field of the proper strength whose orientation is as close as
possible to 90° to the direction of the suspected discontinuity
(see 4.3.2). Making the surface smoother improves mobility of
the magnetic particles under the influence of the magnetic field
to collect on the surface where magnetic flux leakage occurs.
6. Equipment
6.1 Types—There are a number of types of equipment
available for magnetizing ferromagnetic parts and components.
With the exception of a permanent magnet, all equipment
requires a power source capable of delivering the required
current levels to produce the magnetic field. The current used
dictates the sizes of cables and the capability of relays,
switching contacts, meters and rectifier if the power source is
alternating current.
6.2 Portability—Portability, which includes the ability to
hand carry the equipment, can be obtained from yokes. Their
size limits their ability to provide the magnetic fields that can
be obtained from equipment with larger current flows. General
purpose mobile equipment which may be truck mounted, is
usually designed either for use with prods on the ends of two
cables or with only the cables which are attached to the piece
being examined, threaded through an opening in it or wrapped
around it. Mobility is limited by the cable and size and the
environment. Underwater examination on oil drilling platforms
and oil production platforms offshore are examples of a hostile
environment.
6.3 Yokes—Yokes are usually C-shaped electromagnets
which induce a magnetic field between the poles (legs) and are
used for local magnetization (Fig. 1). Many portable yokes
have articulated legs (poles) that allow the legs to be adjusted
to contact irregular surfaces or two surfaces that join at an
angle.
6.3.1 Permanent Magnets—Permanent magnets are avail-
able but their use may be restricted for many applications.
Permanent magnets can lose their magnetic field generating
capacity by being partially demagnetized by a stronger flux
field, being damaged, or dropped. In addition, the particle
mobility, created by AC and half-wave rectified current pulsa-
tions in electromagnetic yokes, is not present. Particles, steel
filings, chips, and scale clinging to the poles can create a
housekeeping problem.
6.4 Prods—Prods are used for local magnetizations, see Fig.
2. The prod tips that contact the piece should be aluminum,
copper braid, or copper pads rather than solid copper. With
solid copper tips, accidental arcing during prod placement or
removal can cause copper penetration into the surface which
may result in metallurgical damage (softening, hardening,
cracking, etc.). See 12.3.1.1(a). Open-circuit voltages should
not exceed 25 V.
6.4.1 Remote Control Switch—A remote-control switch,
which may be built into the prod handles, should be provided
to permit the current to be turned on after the prods have been
properly placed and to turn it off before the prods are removed
in order to minimize arcing (arc burns). (See 12.3.1.1(a).)
6.5 Black Light—The black light must be capable of devel-
oping the required wavelengths of 330 to 390 nm with an
intensity at the examination surface that satisfies 7.1.2. Wave-
lengths at or near 365 nm shall predominate. Suitable filters
should remove the extraneous visible light emitted by black
lights (violet or blue 405 and 435-nm Hg lines and greenish-
yellow 577-nm Hg line). Some high-intensity black light bulbs
may emit unacceptable amounts of greenish-yellow light which
may cause fluorescent indications to become invisible. A drop,
greater than 10 %, in line voltage greater than 610 % can
cause a change in black light output with consequent incon-
sistent performance. A constant voltage transformer should be
(a) (b)
FIG. 1 Yoke Method of Part Magnetization
E 709
4
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
used where there is evidence of voltage changes greater than
10 %.
6.6 Equipment Verification—See Section 20.
7. Examination Area
7.1 Light Intensity for Examination—Magnetic indications
found using nonfluorescent particles are examined under vis-
ible light. Indications found using fluorescent particles must be
examined under black (ultraviolet) light. This requires a
darkened area with accompanying control of the visible light
intensity.
7.1.1 Visible Light Intensity—The intensity of the visible
light at the surface of the part/work piece undergoing exami-
nation should be a minimum of 100 foot candles (1000 lux).
The intensity of ambient visible light in the darkened area
where fluorescent magnetic particles examination is performed
should not exceed 2 foot candles (20 lux).
7.1.1.1 Field Inspections—For some field inspections using
nonfluorescent particles, visible light intensities as low as 50
foot candles (500 lux) may be used when agreed on by the
contracting agency.
7.1.2 Black (Ultraviolet) Light:
7.1.2.1 Black Light Intensity—The black light intensity at
the examination surface shall be not less than 1000 µW/cm2
when measured with a suitable black light meter.
7.1.2.2 Black Light Warm-up—Allow the black light to
warm up for a minimum of 5 min prior to its use or
measurement of the intensity of the ultraviolet light emitted.
7.1.3 Dark Area Eye Adaptation—The generally accepted
practice is that an inspector be in the darkened area at least one
(1) minute so that his/her eyes will adapt to dark viewing prior
to examining parts under UV illumination.11
Caution—
Photochromic or permanently tinted lenses should not be worn
during examination.
7.2 Housekeeping—The examination area should be kept
free of interfering debris. If fluorescent materials are involved,
the area should also be kept free of fluorescent objects not
related to the part/piece being examined.
8. Magnetic Particle Materials
8.1 Magnetic Particle Properties:
8.1.1 Dry Particle Properties—AMS 3040 describes the
generally accepted properties of dry method particles.
8.1.2 Wet Particle Properties—The following documents
describe the generally accepted properties of wet method
particles in their various forms:
AMS 3041
AMS 3042
AMS 3043
AMS 3044
AMS 3045
AMS 3046
8.1.3 Suspension Vehicle— The suspension vehicle for wet-
method examination may be either a light oil distillate fluid
(refer to AMS 2641 or A-A-52930) or a conditioned water
vehicle (refer to AS 4792).
11
Drury, Colin G., and Watson, Jean, “Human Factors Good Practices in
Fluorescent Penetrant Inspection”, http://hfskyway.faa.gov, then “documents”, then
“Research Reports 98–99”, then “search” for “fpi”, then “go”.
(a) Prod Magnetization (b) Copper-Braided Tip Prods
(c) Single-Prod Contacts Magnetization (d) Double-Prod Contacts
FIG. 2 Localized Area Magnetization Using Prod Technique
E 709
5
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
8.2 Particle Types—The particles used in either dry or wet
magnetic particle examination techniques are basically finely
divided ferromagnetic materials which have been treated to
impart color (fluorescent and nonfluorescent) in order to make
them highly visible (contrasting) against the background of the
surface being examined. The particles are designed for use
either as a free flowing dry powder or for suspension at a given
concentration in a suitable liquid medium.
8.3 Particle Characteristics—The magnetic particles must
have high permeability to allow ease of magnetizing and
attraction to the discontinuity and low retentivity so they will
not be attracted (magnetic agglomeration) to each other.
Control of particle size and shape is required to obtain
consistent results. The particles should be nontoxic, free from
rust, grease, paint, dirt, and other deleterious materials that
might interfere with their use; see 20.5 and 20.6. Both dry and
wet particles are considered safe when used in accordance with
the manufacturer’s instructions. They generally afford a very
low hazard potential with regard to flammability and toxicity.
8.4 Dry Particles—Dry magnetic powders are designed to
be used as supplied and are applied by spraying or dusting
directly onto the surface of the part being examined. They are
generally used on an expendable basis although the particles
may be collected and reused. However, to maintain particle
size and control possible contamination, this is not a normal
practice. Dry powders may also be used under extreme
environmental conditions. They are not affected by cold;
therefore examination can be carried out at temperatures that
would thicken or freeze wet baths. They are also heat resistant;
some powders may be usable at temperatures up to 600°F
(315°C). Some colored, organic coatings applied to dry par-
ticles to improve contrast lose their color at temperatures this
high, making the contrast less effective. Fluorescent dry
particles cannot be used at this high a temperature; the
manufacturer should be contacted for the temperature limita-
tion or tests should be run.
8.4.1 Advantages—The dry magnetic particle technique is
generally superior to the wet technique for detection of
near-surface discontinuities: (a) for large objects when using
portable equipment for local magnetization; (b) superior par-
ticle mobility is obtained for relatively deep-seated flaws
half-wave rectified current as the magnetizing source; (c) ease
of removal.
8.4.2 Disadvantages—The dry magnetic particle technique;
(a) cannot be used in confined areas without proper safety
breathing apparatus; (b) can be difficult to use in overhead
magnetizing positions; (c) does not always leave evidence of
complete coverage of part surface as with the wet technique;
(d) is likely to have lower production rates than the wet
technique; and (e) is difficult to adapt to any type of automatic
system.
8.4.3 Nonfluorescent Colors—Although dry magnetic par-
ticle powder can be almost any color, the most frequently
employed colors are light gray, black, red, or yellow. The
choice is generally based on maximum contrast with the
surface to be examined. The examination is done under visible
light.
8.4.4 Fluorescent—Fluorescent dry magnetic particles are
also available, but are not in general use primarily because of
their higher cost and use limitations. They require a black light
source and a darkened work area. These requirements are not
often available in the field-type locations where dry magnetic
particle examinations are especially suitable.
8.4.5 Dual Colors—Dual-colored particles are available
that are readily detectable in visible light and also display
fluorescence when viewed under ultra-violet light or a combi-
nation visible and ultra-violet light. Use in accordance with the
manufacturer’s recommendations.
8.5 Wet Particle Systems—Wet magnetic particles are de-
signed to be suspended in a vehicle such as water or light
petroleum distillate at a given concentration for application to
the test surface by flowing, spraying, or pouring. They are
available in both fluorescent and nonfluorescent concentrates.
In some cases the particles are premixed with the suspending
vehicle by the supplier, but usually the particles are supplied as
a dry concentrate or paste concentrate which is mixed with the
distillate or water by the user. The suspensions are normally
used in wet horizontal magnetic particle equipment in which
the suspension is retained in a reservoir and recirculated for
continuous use. The suspension may also be used on an
expendable basis dispensed from an aerosol.
8.5.1 Primary Use—Because the particles used are smaller,
wet method techniques are generally used to locate smaller
discontinuities than the dry method is used for. The liquid
vehicles used will not perform satisfactorily when their viscos-
ity exceeds 5cSt (5 mm2
/s) at the operating temperature. If the
suspension vehicle is a hydrocarbon, its flash point limits the
top temperature. Mixing equipment is usually required to keep
wet method particles uniformly in suspension.
8.5.2 Where Used—The wet fluorescent method usually is
performed indoors or in areas where shelter and ambient light
level can be controlled and where proper application equip-
ment is available.
8.5.3 Color—The color chosen for any given examination
should be one that best contrasts with the examination surface.
Because contrast is invariably higher with fluorescent materi-
als, these are utilized in most wet process examinations.
Fluorescent wet method particles normally glow a bright
yellow-green when viewed under black light, although other
colors are available. Non-fluorescent particles are usually black
or reddish brown, although other colors are available. Dual-
colored particles are available that are readily detectable in
visible light and also display fluorescence when viewed under
ultra-violet light or a combination visible and ultra-violet light.
Refer to 8.5.5.
8.5.4 Suspension Vehicles—Generally the particles are sus-
pended in a light petroleum (low-viscosity) distillate or condi-
tioned water. (If sulfur or chlorine limits are specified, use Test
Methods D 129 and D 808 to determine their values.
8.5.4.1 Petroleum Distillates—Low-viscosity light petro-
leum distillates vehicles (AMS 2641 Type 1 or equal) are ideal
for suspending both fluorescent and nonfluorescent magnetic
particles and are commonly employed.
(1) Advantages—Two significant advantages for the use of
petroleum distillate vehicles are: (a) the magnetic particles are
E 709
6
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
suspended and dispersed in petroleum distillate vehicles with-
out the use of conditioning agents; and (b) the petroleum
distillate vehicles provide a measure of corrosion protection to
parts and the equipment used.
(2) Disadvantages—Principal disadvantages are flamma-
bility and availability. It is essential, therefore, to select and
maintain readily available sources of supply of petroleum
distillate vehicles that have as high a flash point as practicable
to avoid possible flammability problems.
(3) Characteristics—Petroleum distillate vehicles to be
used in wet magnetic particle examination should possess the
following: (a) viscosity should not exceed 3.0 cSt (3 mm2
/s) at
100°F (38°C) and not more than 5.0 cSt (5 mm2
/s) at the lowest
temperature at which the vehicle will be used; when tested in
accordance with Test Method D 445, in order not to impede
particle mobility (see 20.7.3), (b) minimum flash point, when
tested in accordance with Test Methods D 93, should be 200°F
(93°C) in order to minimize fire hazards (see 20.7.4), (c)
odorless; not objectionable to user, (d) low inherent fluores-
cence if used with fluorescent particles; that is, it should not
interfere significantly with the fluorescent particle indications
(see 20.6.4.1), and (e) nonreactive; should not degrade sus-
pended particles.
8.5.4.2 Water Vehicles with Conditioning Agents—Water
may be used as a suspension vehicle for wet magnetic particles
provided suitable conditioning agents are added which provide
proper wet dispersing, in addition to corrosion protection for
the parts being tested and the equipment in use. Plain water
does not disperse some types of magnetic particles, does not
wet all surfaces, and is corrosive to parts and equipment. On
the other hand, water suspensions of magnetic particles are
safer to use since they are nonflammable. The selection and
concentration of the conditioning agent should be as recom-
mended by the particle manufacturer. The following are
recommended properties for water vehicles containing condi-
tioning agents for use with wet magnetic particle examination:
(1) Wetting Characteristics—The vehicle should have
good wetting characteristics; that is, wet the surface to be
tested, give even, complete coverage without evidence of
dewetting the test surface. Smooth test surfaces require that a
greater percentage of wetting agent be added than is required
for rough surface. Nonionic wetting agents are recommended
(see 20.7.5).
(2) Suspension Characteristics—Impart good dispersabil-
ity; that is, thoroughly disperse the magnetic particles without
evidence of particle agglomeration.
(3) Foaming—Minimize foaming; that is, it should not
produce excessive foam which would interfere with indication
formation or cause particles to form scum with the foam.
(4) Corrosiveness—It should not corrode parts to be tested
or the equipment in which it is used.
(5) Viscosity Limit—The viscosity of the conditioned water
should not exceed a maximum viscosity of 3 cSt (3 mm2
/s) at
100°F (38°C) (see 20.7.3).
(6) Fluorescence—The conditioned water should not fluo-
resce if intended for use with fluorescent particles.
(7) Nonreactiveness—The conditioned water should not
cause deterioration of the suspended magnetic particles.
(8) Water pH—The pH of the conditioned water should not
be less than 7.0 or exceed 10.5.
(9) Odor—The conditioned water should be essentially
odorless.
8.5.5 Concentration of Wet Magnetic Particle Suspension—
The initial bath concentration of suspended magnetic particles
should be as specified or as recommended by the manufacturer
and should be checked by settling volume measurements and
maintained at the specified concentration on a daily basis. If the
concentration is not maintained properly, examination results
can vary greatly. The concentration of dual-colored particles in
the wet-method bath suspension may be adjusted to best
perform in the desired lighting environment. Higher particle
concentration is recommended for visible light areas and lower
particle concentration is recommended for ultraviolet light
areas. Use in accordance with the particle manufacturer’s
recommendations.
8.5.6 Application of Wet Magnetic Particles (see 15.2).
8.5.7 Magnetic Slurry/Paint Systems—Another type of ex-
amination vehicle is the magnetic slurry/paint type consisting
of a heavy oil in which flake-like particles are suspended. The
material is normally applied by brush before the part is
magnetized. Because of the high viscosity, the material does
not rapidly run off surfaces, facilitating the inspection of
vertical or overhead surfaces. The vehicles may be combus-
tible, but the fire hazard is very low. Other hazards are very
similar to those of the oil and water vehicles previously
described.
8.5.8 Polymer-Based Systems—The vehicle used in the
magnetic polymer is basically a liquid polymer which disperses
the magnetic particles and which cures to an elastic solid in a
given period of time, forming fixed indications. Viscosity
limits of standard wet technique vehicles do not apply. Care
should be exercised in handling these polymer materials. Use
in accordance with manufacturer’s instructions and precau-
tions. This technique is particularly applicable to examine
areas of limited visual accessibility, such as bolt holes.
9. Part Preparation
9.1 General—The surface of the part to be examined should
be essentially clean, dry, and free of contaminants such as dirt,
oil, grease, loose rust, loose mill sand, loose mill scale, lint,
thick paint, welding flux/slag, and weld splatter that might
restrict particle movement. See 15.1.2 about applying dry
particles to a damp/wet surface. When testing a local area, such
as a weld, the areas adjacent to the surface to be examined, as
agreed by the contracting parties, must also be cleaned to the
extent necessary to permit detection of indications.
9.1.1 Nonconductive Coatings—Thin nonconductive coat-
ings, such as paint in the order of 0.02 to 0.05 mm (1 or 2 mil)
will not normally interfere with the formation of indications,
but they must be removed at all points where electrical contact
is to be made for direct magnetization. Indirect magnetization
does not require electrical contact with the part/piece. See
Section 12.2. If a nonconducting coating/plating is left on the
area to be examined that has a thickness greater than 0.05 mm
(2 mil), it must be demonstrated that discontinuities can be
detected through the maximum thickness applied.
9.1.2 Conductive Coatings—A conductive coating (such as
E 709
7
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
chrome plating and heavy mill scale on wrought products
resulting from hot forming operations) can mask discontinui-
ties. As with nonconductive coatings, it must be demonstrated
that the discontinuities can be detected through the coating.
9.1.3 Residual Magnetic Fields—If the part/piece holds a
residual magnetic field from a previous magnetization that will
interfere with the examination, the part must be demagnetized.
See Section 18.
9.2 Cleaning Examination Surface—Cleaning of the test
surface may be accomplished by detergents, organic solvents,
or mechanical means. As-welded, as-rolled, as-cast, or as-
forged surfaces are generally satisfactory, but if the surface is
unusually nonuniform, as with burned-in sand or a very rough
weld deposit, interpretation may be difficult because of me-
chanical entrapment of the magnetic particles. In case of doubt,
any questionable area should be recleaned and reexamined (see
9.1). An extensive presentation of applicable cleaning methods
is described in Annex A1 of Test Method E 165.
9.2.1 Plugging and Masking Small Holes and Openings—
Unless prohibited by the purchaser, small openings and oil
holes leading to obscure passages or cavities can be plugged or
masked with a suitable nonabrasive material which is readily
removed. In the case of engine parts, the material must be
soluble in oil. Effective masking must be used to protect
components that may be damaged by contact with the particles
or particle suspension.
10. Sequence of Operations
10.1 Sequencing Particle Application and Establishing
Magnetic Flux Field—The sequence of operation in magnetic
particle examination applies to the relationship between the
timing and application of particles and establishing the mag-
netizing flux field. Two basic techniques apply, that is, con-
tinuous (see 10.1.1 and 10.1.2) and residual (see 10.1.3), both
of which are commonly employed in industry.
10.1.1 Continuous Magnetization—Continuous magnetiza-
tion is employed for most applications utilizing either dry or
wet particles and should be used unless specifically prohibited
in the contract, purchase order, or specification. The sequence
of operation for the dry and the wet continuous magnetization
techniques are significantly different and are discussed sepa-
rately in 10.1.1.1 and 10.1.1.2.
10.1.1.1 Dry Continuous Magnetization Technique—Unlike
a wet suspension, dry particles lose most of their mobility
when they contact the surface of a part. Therefore, it is
imperative that the part/area of interest be under the influence
of the applied magnetic field while the particles are still
airborne and free to be attracted to leakage fields. This dictates
that the flow of magnetizing current be initiated prior to the
application of dry magnetic particles and terminated after the
application of powder has been completed and any excess has
been blown off. Magnetizing currents of the half-wave rectified
alternating and unrectified AC provide additional particle
mobility on the surface of the part. Examination with dry
particles is usually carried out in conjunction with prod-type
localized magnetizations, and buildup of indications is ob-
served as the particles are being applied.
10.1.1.2 Wet Continuous Magnetization Technique—The
wet continuous magnetization technique generally applies to
those parts processed on a horizontal wet type unit. In practice,
it involves bathing the part with the examination medium to
provide an abundant source of suspended particles on the
surface of the part and terminating the bath application
immediately prior to cutting off of the magnetizing current. The
duration of the magnetizing current is typically on the order of
1⁄2 s with two or more shots given to the part.
10.1.1.3 Polymer or Slurry Continuous Magnetization
Technique—Prolonged or repeated periods of magnetization
are often necessary for polymer- or slurry-base suspensions
because of slower inherent magnetic particle mobility in the
high-viscosity suspension vehicles.
10.1.2 True Continuous Magnetization Technique—In this
technique, the magnetizing current is sustained throughout
both the processing and examination of the part.
10.1.3 Residual Magnetization Techniques:
10.1.3.1 Residual Magnetization—In this technique, the
examination medium is applied after the magnetizing force has
been discontinued. It can be used only if the material being
tested has relatively high retentivity so the residual leakage
field will be of sufficient strength to attract and hold the
particles and produce indications. This technique may be
advantageous for integration with production or handling
requirements or for intentionally limiting the sensitivity of the
examination. It has found wide use examining pipe and tubular
goods. Unless demonstrations with typical parts indicate that
the residual field has sufficient strength to produce relevant
indications of discontinuities (see 20.8) when the field is in
proper orientation, the continuous method should be used.
10.1.3.2 Current Quick Break—Equipment, full-wave rec-
tified AC, for residual magnetization must be designed to
provide a consistent quick break of the magnetizing current.
11. Types of Magnetizing Currents
11.1 Basic Current Types—The four basic types of current
used in magnetic particle examination to establish part mag-
netization are alternating current, single phase half-wave rec-
tified alternating current, full-wave rectified alternating current,
and for a special application, DC.
11.1.1 Alternating Current (AC)—Part magnetization with
alternating current is preferred for those applications where
examination requirements call for the detection of discontinui-
ties, such as fatigue cracks, that are open to the surface.
Associated with AC is a “skin effect” that confines the
magnetic field at or near to the surface of a part. In contrast,
both half-wave rectified alternating current and full-wave
rectified alternating current produce a magnetic field having
maximum penetrating capabilities which should be used when
near-surface discontinuities are of concern. Alternating current
is also extensively used for the demagnetization of parts after
examination. The through-coil technique is normally used for
this purpose due to its simple, fast nature. See Fig. 3.
11.1.2 Half-Wave Rectified Alternating Current—Half-wave
rectified alternating current is frequently used in conjunction
with dry particles and localized magnetization (for example,
prods or yokes) to achieve some depth of penetration for
detection of typical discontinuities found in weldments and
ferrous castings. As with AC for magnetization, single-phase
E 709
8
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
current is utilized and average value measured as “magnetizing
current.”
11.1.3 Full-Wave Rectified Alternating Current—Full-wave
rectified alternating current may utilize single- or three-phase
current. Three-phase current has the advantage of lower line
amperage whereas single-phase equipment is less expensive.
Full-wave rectified AC is commonly used when the residual
method is to be employed. With the continuous method,
full-wave rectified AC is used for magnetization of coated and
plated parts. Because particle movement, either dry or wet is
noticeably slower, precautions must be taken to ensure that
sufficient time is allowed for formation of indications.
11.1.4 Direct Current (DC)—A bank of batteries or a D C
generator produce a direct magnetizing current. They have
largely given way to half-wave rectified or full-wave rectified
AC except for a few specialized applications, primarily be-
cause of battery cost and maintenance. One such example is the
charging of a bank of capacitors, which on discharge is used to
establish a residual magnetic field in tubing, casing, line pipe,
and drill pipe.
12. Part Magnetization Techniques
12.1 Examination Coverage—All examinations should be
conducted with sufficient area overlap to assure the required
coverage at the specified sensitivity has been obtained.
12.2 Direct and Indirect Magnetization—A part can be
magnetized either directly or indirectly. For direct magnetiza-
tion the magnetizing current is passed directly through the part
creating a circular magnetic field in the part. With indirect
magnetization techniques a magnetic field is induced in the part
which can create a circular/toroidal, longitudinal, or multidi-
rectional magnetic field in the part. The techniques described in
20.8 for verifying that the magnetic fields have the anticipated
direction and strength should be employed. This is especially
important when using the multidirection technique to examine
complex shapes.
12.3 Choosing Magnetization Technique—The choice of
direct or indirect magnetization will depend on such factors as
size, configuration, or ease of processing. Table 1 compares the
advantages and limitations of the various methods of part
magnetization.
TABLE 1 Advantages and Limitations of the Various Ways of Magnetizing a Part
Magnetizing Technique and Material Form Advantages Limitations
I. Direct Contact Part Magnetization (see 12.3.1)
Head/Tailstock Contact
Solid, relatively small parts (castings,
forgings, machined pieces) that can be
processed on a horizontal wet unit
1. Fast, easy technique. 1. Possibility of arc burns if poor contact conditions
exist.
2. Circular magnetic field surrounds current path. 2. Long parts should be magnetized in sections to
facilitate bath application without resorting to an
overly long current shot.
3. Good sensitivity to surface and near-surface discontinuities.
4. Simple as well as relatively complex parts can usually be
easily processed with one or more shots.
5. Complete magnetic path is conducive to maximizing residual
characteristics of material.
Large castings and forgings 1. Large surface areas can be processed and examined in
relatively short time.
1. High amperage requirements (16 000 to 20 000 A)
dictate special DC power supply.
Cylindrical parts such as tubing, pipe, hollow
shafts, etc.
1. Entire length can be circularly magnetized by contacting,
end to end.
1. Effective field limited to outside surface and cannot
be used for inside diameter examination.
2. Ends must be conductive to electrical contacts and
capable of carrying required current without excessive
heat. Cannot be used on oil country tubular goods
because of possibility of arc burns.
Long solid parts such as billets, bars, shafts,
etc.
1. Entire length can be circularly magnetized by contacting,
end to end.
1. Voltage requirements increase as length increases
due to greater impedance of cable and part.
2. Current requirements are independent of length. 2. Ends must be conductive to electrical contact and
capable of carrying required current without excessive
heat.
3. No end loss.
Prods: Welds 1. Circular field can be selectively directed to weld area by
prod placement.
1. Only small area can be examined at one time.
FIG. 3 Coil Magnetization
E 709
9
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
TABLE 1 Continued
Magnetizing Technique and Material Form Advantages Limitations
2. In conjunction with half-wave rectified alternating current and
dry powder, provides excellent sensitivity to subsurface
discontinuities as well as surface type.
2. Arc burns due to poor contact.
3. Flexible, in that prods, cables, and power packs can be
brought to examination site.
3. Surface must be dry when dry powder is being used.
4. Prod spacing must be in accordance with the
magnetizing current level.
Large castings or forgings 1. Entire surface area can be examined in small increments
using nominal current values.
1. Coverage of large surface area require a multiplicity
of shots that can be very time-consuming.
2. Circular field can be concentrated in specific areas that
historically are prone to discontinuities.
2. Possibility of arc burns due to poor contact. Surface
should be dry when dry powder is being used.
3. Equipment can be brought to the location of parts that are
difficult to move.
4. In conjunction with half-wave rectified alternating current and
dry powder, provides excellent sensitivity to near surface
subsurface type discontinuities that are difficult to locate by
other methods.
II. Indirect Part Magnetization (see 12.3.2)
Central Conductor
Miscellaneous parts having holes through
which a conductor can be placed such as:
Bearing race
Hollow cylinder
Gear
Large nut
1. No electrical contact to part and possibility of arc burns
eliminated.
1. Size of conductor must be ample to carry required
current.
2. Circumferentially directed magnetic field is generated in all
surfaces, surrounding the conductor (inside diameter, faces,
etc.).
2. Ideally, conductor should be centrally located within
hole.
3. Ideal for those cases where the residual method is
applicable.
3. Larger diameters require repeated magnetization
with conductor against inside diameter and rotation of
part between processes. Where continuous
magnetization technique is being employed,
examination is required after each magnetization.
4. Light weight parts can be supported by the central
conductor.
5. Multiple turns may be used to reduce current required.
Large clevis
Pipe coupling, casing/tubing
Tubular type parts such as:
Pipe/Casting
Tubing
Hollow shaft
1. No electrical contact of part required. 1. Outside surface sensitivity may be somewhat less
than that obtained on the inside surface for large
diameter and extremely heavy wall.
2. Inside diameter as well as outside diameter examination.
3. Entire length of part circularly magnetized.
Large valve bodies and similar parts 1. Provides good sensitivity for detection of discontinuities
located on internal surfaces.
1. Outside surface sensitivity may be somewhat less
than that obtained on the inside diameter for heavy
wall.
Coil/Cable Wrap
Miscellaneous medium-sized parts where the
length predominates such as a crankshaft
1. All generally longitudinal surfaces are longitudinally
magnetized to effectively locate transverse discontinuities.
1. Length may dictate multiple shot as coil is
repositioned.
Large castings, forgings, or shafting 1. Longitudinal field easily attained by means of cable
wrapping.
1. Multiple magnetization may be required due to
configuration of part.
Miscellaneous small parts 1. Easy and fast, especially where residual magnetization is
applicable.
1. L/D (length/diameter) ratio important consideration in
determining adequacy of ampere-turns.
2. No electrical contact. 2. Effective L/D ratio can be altered by utilizing pieces
of similar cross-sectional area.
3. Relatively complex parts can usually be processed with
same ease as those with simple cross section.
3. Use smaller coil for more intense field.
4. Sensitivity diminishes at ends of part due to general
leakage field pattern.
5. Quick break desirable to minimize end effect on
short parts with low L/D ratio.
Induced Current Fixtures
Examination of ring-shaped part for circumfer-
ential-type discontinuities.
1. No electrical contact. 1. Laminated core required through ring.
2. All surface of part subjected to toroidal-type mag- netic field. 2. Type of magnetizing current must be compatible with
method.
3. Single process for 100 % coverage. 3. Other conductors encircling field must be avoided.
4. Can be automated. 4. Large diameters require special consideration.
Ball examination 1. No electrical contact. 1. For small-diameter balls, limited to residual
magnetization.
2. 100 % coverage for discontinuities in any direction with
three-step process and proper orientation between steps.
3. Can be automated.
E 709
10
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
TABLE 1 Continued
Magnetizing Technique and Material Form Advantages Limitations
Disks and gears 1. No electrical contact. 1. 100 % coverage may require two-step process with
core or pole-piece variation, or both.
2. Good sensitivity at or near periphery or rim. 2. Type of magnetizing current must be compatible with
part geometry.
3. Sensitivity in various areas can be varied by core or pole-
piece selection.
Yokes:
Examination of large surface areas for
surface-type discontinuities.
1. No electrical contact. 1. Time consuming.
2. Highly portable. 2. Must be systematically repositioned in view of
random discontinuity orientation.
3. Can locate discontinuities in any direction with proper
orientation.
Miscellaneous parts requiring examination of
localized areas.
1. No electrical contact. 1. Must be properly positioned relative to orientation of
discontinuities.
2. Good sensitivity to direct surface discontinuities. 2. Relatively good contact must be established be-
tween part and poles.
3. Highly portable. 3. Complex part geometry may cause difficulty.
4. Wet or dry technique. 4. Poor sensitivity to subsurface-type discontinuities
except in isolated areas.
5. Alternating-current type can also serve as demagnetizer in
some instances.
12.3.1 Direct Contact Magnetization—For direct magneti-
zation, physical contact must be made between the ferromag-
netic part and the current carrying electrodes connected to the
power source. Both localized area magnetization and overall
part magnetization are direct contact means of part magneti-
zation achieved through the use of prods, head and tailstock,
clamps, and magnetic leeches.
12.3.2 Localized Area Magnetization:
12.3.2.1 Prod Technique—The prod electrodes are first
pressed firmly against the test part (Fig. 2(a)). The magnetizing
current is then passed through the prods and into the area of the
part in contact with the prods. This establishes a circular
magnetic field in the part around and between each prod
electrode, sufficient to carry out a local magnetic particle
examination (Fig. 2(c) and Fig. 2(d)). Caution: Extreme care
should be taken to maintain clean prod tips, to minimize
heating at the point of contact and to prevent arc burns and
local overheating on the surface being examined since these
may cause adverse effects on material properties. Arc burns
cause metallurgical damage; if the tips are solid copper, copper
penetration into the part may occur. Prods should not be used
on machined surfaces or on aerospace component parts.
(1) Unrectified AC limits the prod technique to the detec-
tion of surface discontinuities. Half-wave rectified AC is most
desirable since it will detect both surface and near-surface
discontinuities. The prod technique generally utilizes dry
magnetic particle materials due to better particle mobility. Wet
magnetic particles are not generally used with the prod
technique because of potential electrical and flammability
hazards.
(2) Proper prod examination requires a second placement
with the prods rotated approximately 90° from the first
placement to assure that all existing discontinuities are re-
vealed. Depending on the surface coverage requirements,
overlap between successive prod placements may be necessary.
On large surfaces, it is good practice to layout a grid for
prod/yoke placement.
12.3.2.2 Manual Clamp/Magnetic Leech Technique—Local
areas of complex components may be magnetized by electrical
contacts manually clamped or attached with magnetic leeches
to the part (Fig. 4). As with prods, sufficient overlap may be
necessary if testing of the contact location is required.
12.3.2.3 Overall Magnetization:
(1) Head and Tailstock Contact—Parts may be clamped
between two electrodes (such as a head and tailstock of
horizontal wet magnetic particle equipment) and the magne-
tizing current applied directly through the part (Fig. 5). The
size and shape of the part will determine whether both field
directions can be obtained with such equipment.
(2) Clamps—The magnetizing current may be applied to the
FIG. 4 Direct-Contact Magnetization Through Magnetic Leech
Clamp of Part
E 709
11
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
test part by clamping the current carrying electrodes to the part,
producing a circular magnetic field (Fig. 6).
(3) Multidirectional Magnetization Technique—With suit-
able circuitry, it is possible to produce a multidirectional
(oscillating) field in a part by selectively switching the mag-
netic field within the part between electrode contacts/clamps
positioned approximately 90° apart. This permits building up
indications in all possible directions and may be considered the
equivalent of magnetizing in two or more directions (Fig. 7).
On some complex shapes as many as 16 to 20 steps may be
required with conventional equipment. With multidirectional
magnetization, it is usually possible to reduce the magnetizing
steps required by more than half. It is essential that the wet
continuous method, be used and that the magnetic field
direction and relative intensity be determined by one or more
of the techniques described in 20.8.
12.3.3 Indirect Magnetization—Indirect part magnetization
involves the use of a preformed coil, cable wrap, yoke, or a
central conductor to induce a magnetic field. Coil, cable wrap,
and yoke magnetization are referred to as longitudinal magne-
tization in the part (see 13.3).
12.3.3.1 Coil and Cable Magnetization—When coil (Fig. 3)
or cable wrap (Fig. 8) techniques are used, the magnetic field
strength is proportional to ampere turns and depends on simple
geometry (see 14.3.2).
12.3.3.2 Central Conductor, Induced Current
Magnetization—Indirect circular magnetization of hollow
pieces/parts can be performed by passing the magnetizing
current through a central conductor (Fig. 9(a) and Fig. 9(b)) or
cable used as a central conductor or through an induced current
fixture (Fig. 9(c)).
12.3.3.3 Yoke Magnetization—A magnetic field can be in-
duced into a part by means of an electromagnet (see Fig. 1),
where the part or a portion thereof becomes the magnetic path
between the poles (acts as a keeper) and discontinuities
preferentially transverse to the alignment of the pole pieces are
indicated. Most yokes are energized by AC, half-wave rectified
FIG. 5 Direct Contact Magnetization Through Head/Tailstock
FIG. 6 Direct Contact Overall Magnetization
FIG. 7 Multidirectional–Overall Magnetization
FIG. 8 Cable Magnetization
E 709
12
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
AC, or full-wave rectified AC. A permanent magnet can also
introduce a magnetic field in the part but its use is restricted
(see 6.3.1).
13. Direction of Magnetic Fields
13.1 Discontinuity Orientation vs. Magnetic Field
Direction—Since indications are not normally obtained when
discontinuities are parallel to the magnetic field, and since
indications may occur in various or unknown directions in a
part, each part must be magnetized in at least two directions
approximately at right angles to each other as noted in 5.3.2.
On some parts circular magnetization may be used in two or
more directions, while on others both circular and longitudinal
magnetization are used. A multidirectional field can also be
employed to achieve part magnetization in more than one
direction.
13.2 Circular Magnetization—Circular magnetization (Fig.
10) is the term used when electric current is passed through a
part, or by use of a central conductor (see 12.3.3.2) through a
central opening in the part, inducing a magnetic field at right
angles to the current flow.
13.3 Toroidal Magnetization—When magnetizing a part
with a toroidal shape, such as a solid wheel or the disk with a
center opening, an induced field that is radial to the disk is most
useful for the detection of discontinuities in a circumferential
direction. In such applications this field may be more effective
than multiple shots across the periphery.
13.4 Longitudinal Magnetization—Longitudinal magnetiza-
tion (Fig. 11) is the term used when a magnetic field is
generated by an electric current passing through a multiturn,
Fig. 12, or laminated coil, Fig. 13, which encloses the part or
section of the part to be examined.
13.5 Multidirectional Magnetization—Multidirectional
magnetization may be used to fulfill the requirement for
(a) Use of Central Conductor on Multipart Magnetization (b) Use of Central Conductor for Localized Magnetization
(c) Use of a Special Induced Current Fixture
FIG. 9 Central Conductor Induced Magnetization
FIG. 10 Circular Magnetization
E 709
13
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
magnetization in two directions if it is demonstrated that it is
effective in all areas. Test parts in accordance with 20.8.2 or
shims manufactured to the requirements of AS 5371, or as
otherwise approved by the Level III and the Cognizant
Engineering Organization, may be used to verify field direc-
tion, strength, and balance in multidirectional magnetization.
Balance of the field intensity is critical. The field intensity shall
be balanced in all directions. The particle application must be
timed so that the magnetization levels reach full value in all
directions, while the particles are mobile on the surface under
examination. (Refer to Fig. 14.)
13.5.1 When actual parts with known defects are used, the
number and orientation(s) of the defects (for example, axial,
longitudinal, circumferential, etc.) should be noted. The mag-
netic field intensity can be considered as being properly
balanced when all noted defects can be readily identified with
particle indications.
13.5.2 The wet continuous method must be used when
performing multidirectional magnetization.
14. Magnetic Field Strength
14.1 Magnetizing Field Strengths—To produce interpret-
able indications, the magnetic field in the part must have
sufficient strength and proper orientation. For the indications to
be consistent, this field strength must be controlled within
reasonable limits, usually 625 %. Factors that affect the
strength of the field are the size, shape, section thickness,
material of the part/piece, and the technique of magnetization.
Since these factors vary widely, it is difficult to establish rigid
rules for magnetic field strengths for every conceivable con-
figuration.
14.2 Establishing Field Strengths—Sufficient magnetic field
strength can be established by:
14.2.1 Known Discontinuities—Experiments with similar/
identical parts having known discontinuities.
14.2.2 Artificial Discontinuities—The “pie” field indicator
(Fig. 15) and notched shims (Appendix X1) are artificial
discontinuities. Other types of artificial flaws are available and
may be selected as appropriate. See 20.8.
14.2.3 Hall-effect Probe-Tangential Field Strengths—
Tangentially applied field strengths, as measured with a Hall-
effect probe/sensor, in the range from 30 to 60 G (2.4 to 4.8
kAM−1
) should be adequate. See 20.8. Under some circum-
stances some fields in the range from 10 to 150 G may be
required.
14.2.4 Using Empirical Formulas—Section 14.3 has four
empirical formulas for establishing magnetic field strengths;
they are rules of thumb. As such, they must be used with
judgment. Their use may lead to:
14.2.4.1 Over magnetization, which causes excessive par-
ticle background that makes interpretation more difficult if not
impossible.
FIG. 11 Longitudinal Magnetization
FIG. 12 Magnetic Field Produced by an Air Core Coil
FIG. 13 Magnetic Field Produced by a Laminated Core Coil
FIG. 14 Multidirectional Magnetization
FIG. 15 Magnetic Field Indicator
E 709
14
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
14.2.4.2 Poor coverage.
14.2.4.3 Poor choice of test geometries.
14.2.4.4 A combination of the above.
14.3 Guidelines for Establishing Magnetic Fields—The fol-
lowing guidelines can be effectively applied for establishing
proper levels of circular and longitudinal magnetization.
14.3.1 Circular Magnetization—Magnetic Field Strength:
14.3.1.1 Direct Circular Magnetization—When magnetiz-
ing by passing current directly through the part the nominal
current should be 300–800 A/in. of part diameter (12 to 32
A/mm). The diameter of the part shall be taken as the greatest
distance between any two points on the outside circumference
of the part. Currents will normally be 500 A/in. (20 A/mm) or
lower, with the higher currents up to 800 A/in. (32 A/mm)
being used to examine for inclusions or to examine low-
permeability alloys. Amperages of less than 300 A/in. may be
used when part configuration dictates and approval is obtained
from the Level III and the Cognizant Engineering Organiza-
tion.
14.3.1.2 Central Conductor Induced Magnetization—
Central conductors are widely used in magnetic particle
examination to provide:
(1) A circular field on both the inside surface and outside
surface of tubular pieces that cannot be duplicated by the direct
current technique.
(2) A non-contact means of part magnetization virtually
eliminating the possibility of arc burning the material, as can
be the case with current flow through contacts, such as prods or
clamps.
(3) Substantial processing advantages over direct contact
techniques on ring-shaped parts.
(4) In general it is desirable to centrally locate a central
conductor to permit the entire circumference of the part to be
processed at one time. The resulting field is concentric relative
to the axis of the piece and is maximum at the inside surface.
The strength of the magnetic field should be verified by the
means discussed in 20.8. With a centrally located central
conductor, the magnetizing current requirements would be the
same as a solid piece having the same outside diameter.
(5) When using offset central conductors the conductor
passing through the inside of the part is placed against an inside
wall of the part. The current shall be from 12 A per mm of part
diameter to 32 A per mm of part diameter (300 to 800 A/in.).
The diameter of the part shall be taken as the largest distance
between any two points on the outside circumference of the
part. Generally currents will be 500 A/in. (20 A per mm) or
lower with the higher currents (up to 800 A/in.) being used to
examine for inclusions or to examine low permeability alloys
such as precipitation-hardening steels. For examinations used
to locate inclusions in precipitation-hardening steels even
higher currents, up to 1000 A/in. (40 A per mm) may be used.
The distance along the part circumference which may be
effectively examined shall be taken as approximately four
times the diameter of the central conductor, as illustrated in
Fig. 16. The entire circumference shall be examined by rotating
the part on the conductor, allowing for approximately a 10 %
magnetic field overlap. Less overlap, different current levels,
and larger effective regions (up to 360°) may be used if the
presence of suitable field levels is verified.
14.3.1.3 Localized Magnetization:
(1) Using Prods—When using prods on material 3⁄4 in. (19
mm) in thickness or less, 90 to 115 A/in. of prod spacing (3.5
to 4.5 A/mm) shall be used. For material greater than 3⁄4 in. (19
mm) in thickness, 100 to 125 A/in. of prod spacing should be
used. Prod spacing shall not be less than 2 in. (50 mm) or
greater than 8 in. (200 mm). The effective width of the
magnetizing field when using prods is one fourth of the prod
spacing on each side of a line through the prod centers.
(2) Using Yokes—The field strength of a yoke (or a
permanent magnet) can be empirically determined by measur-
ing its lifting power (see 20.3.6). If a Hall-effect probe is used,
it shall be placed on the surface midway between the poles.
14.3.2 Air-Core Coil Longitudinal Magnetization—
Longitudinal part magnetization is produced by passing a
current through a multiturn coil encircling the part or section of
the part to be examined. A magnetic field is produced parallel
to the axis of the coil. The unit of measurement is ampere turns
(NI) (the actual amperage multiplied by the number of turns in
the encircling coil or cable). The effective field extends on
either side of the coil a distance approximately equal to the
radius of the coil being employed. Long parts should be
examined in sections not to exceed this length. There are four
empirical longitudinal magnetization formulas employed for
using encircling coils, the formula to be used depending on the
fill factor. The formulas are included for historical continuity
only. If used its use should be limited to simple shaped parts.
It would be quicker and more accurate to use a Gauss (Tesla)
meter, lay its probe on the part and measure the field rather than
to calculate using the formulas.
14.3.2.1 Low Fill-Factor Coils—In this case, the cross-
sectional area of the fixed encircling coil greatly exceeds the
cross-sectional area of the part (less than 10 % coil inside
diameter). For proper part magnetization, such parts should be
placed well within the coils and close to the inside wall of the
coil. With this low fill-factor, adequate field strength for
eccentrically positioned parts with a length-over-diameter ratio
FIG. 16 Approximate Effective Region of Examination When
Using an Offset Central Conductor (Threader Bar)
E 709
15
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
(L/D) between 3 and 15 is calculated from the following
equations:12
(1) Parts With Low Fill-Factor Positioned Close to Inside
Wall of Coil:
NI 5 K/~L/D! ~610 %! (1)
where:
N = number of turns in the coil,
I = coil current to be used, amperes (A),
K = 45 000 (empirically derived constant),
L = part, length, in., (see Note),
D = part diameter, in.; for hollow parts, see 14.3.2.4, and
NI = ampere turns.
For example, a part 15 in. (38.1 cm) long with 5-in. (12.7-cm)
outside diameter has an L/D ratio of 15/5 or 3. Accordingly, the
ampere turn requirement (NI = 45 000/3) to provide adequate
field strength in the part would be 15 000 ampere turns. If a
five-turn coil or cable is used, the coil amperage requirements
would be (I = 15 000/5) = 3000 A (610 %). A500 turn coil
would require 30 A (610 %).
(2) Parts with a Low Fill-Factor Positioned in the Center
of the Coil:
NI 5 KR/$~6L/D! 2 5%~610 %! (2)
where:
N = number of turns in the coil,
I = coil current to be used, A,
K = 43 000 (empirically derived constant),
R = coil radius, in.,
L = part length, in. (see Note),
D = part diameter, in., for hollow parts (see 14.3.2.4), and
NI = ampere turns.
For example, a part 15 in. (38.1 cm) long with 5-in.
(12.7-cm) outside diameter has a L/D ratio of 15/5 or 3. If a
five-turn 12-in. diameter (6-in. radius) (30.8-cm diameter
(15.4-cm radius)) coil or cable is used, (1) the ampere turns
requirement would be as follows:
NI 5
~43 000 3 6!
~~6 3 3! 2 5!
or 19 846
and (2) the coil amperage requirement would be as follows:
19 846
5 or 3 969 A ~610 %!
14.3.2.2 Intermediate Fill-Factor Coils—When the cross
section of the coil is greater than twice and less than ten times
the cross section of the part being examined:
NI 5 ~NI!hf ~10 2 Y! 1 ~NI!lf ~Y 2 2!/8 (3)
where:
NIhf = value of NI calculated for high fill-factor coils using
Eq 3,
NIlf = value of NI calculated for low fill-factor coils using
Eq 1 or Eq 2, and
Y = ratio of the cross-sectional area of the coil to the
cross section of the part. For example, if the coil has
an inside diameter of 10 in. (25.4 cm) and part (a
bar) has an outside diameter of 5 in. (12.2 cm)
Y 5 ~p~5!2
!/~p~2.5!2
! 5 4
14.3.2.3 High Fill-Factor Coils—In this case, when fixed
coils or cable wraps are used and the cross-sectional area of the
coil is less than twice the cross-sectional area (including
hollow portions) of the part, the coil has a high fill-factor.
(1) For Parts Within a High Fill-Factor Positioned Coil and
for Parts with an L/D ratio equal to or greater than 3:
NI 5
K
$~L/D! 1 2%
~610 %!
where:
N = number of turns in the coil or cable wrap,
I = coil current, A,
K = 35 000 (empirically derived constant),
L = part length, in.,
D = part diameter, in., and
NI = ampere turns.
For example, the application of Eq 3 can be illustrated as
follows: a part 10 in. (25.4 cm) long-with 2-in. (5.08-cm)
outside diameter would have an L/D ratio of 5 and an ampere
turn requirements of NI = 35 000/(5 + 2) or 5000 (610 %)
ampere turns. If a five-turn coil or cable wrap is employed, the
amperage requirement is 5000/5 or 1000 A (610 %).
NOTE 1—For L/D ratios less than 3, a pole piece (ferromagnetic
material approximately the same diameter as part) should be used to
effectively increase the L/D ratio or utilize an alternative magnetization
method such as induced current. For L/D ratios greater than 15, a
maximum L/D value of 15 should be used for all formulas cited above.
14.3.2.4 L/D Ratio for a Hollow Piece—When calculating
the L/D ratio for a hollow piece, D shall be replaced with an
effective diameter Deff calculated using:
Deff 5 2@~At 2 Ah!/p#1/2
where:
At = total cross-sectional area of the part, and
Ah = cross-sectional area of the hollow portion(s) of the
part.
Deff 5 @~OD!2
2 ~ID!2
#1/2
where:
OD = outside diameter of the cylinder, and
ID = inside diameter of the cylinder.
15. Application of Dry and Wet Magnetic Particles
15.1 Dry Magnetic Particles:
15.1.1 Magnetic Fields for Dry Particles—Dry magnetic
powders are generally applied with the continuous magnetizing
12
These equations are included for historical continuity only. It is faster to buy
a Tesla meter, lay the probe on the part and measure the field strength than
calculating using the equations.
E 709
16
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
techniques utilizing AC or half-wave rectified AC or yoke
magnetization. A current duration of at least 1⁄2s should be
used. The current duration should be short enough to prevent
any damage from overheating or from other causes. It should
be noted that AC and half-wave rectified AC impart better
particle mobility to the powder than DC or full-wave rectified
AC. Dry magnetic powders are widely used for magnetic
particle examination of large parts as well as on localized areas
such as welds. Dry magnetic particles are widely used for oil
field applications and are frequently used in conjunction with
capacitor discharge style equipment and the residual method.
15.1.2 Dry Powder Application—Dry powders should be
applied in such a manner that a light uniform, dust-like coating
settles upon the surface of the part/piece while it is being
magnetized. Dry particles must not be applied to a wet surface;
they will have limited mobility. Neither should they be applied
where there is excessive wind. The preferred application
technique suspends the particles in air in such a manner that
they reach the part surface being magnetized in a uniform
cloud with a minimum of force. Usually, specially designed
powder blowers and hand powder applicators are employed
(Fig. 1(b) and Fig. 4). Dry particles should not be applied by
pouring, throwing, or spreading with the fingers.
15.1.3 Excess Powder Removal—Care is needed in both the
application and removal of excess dry powder. While the
magnetizing current is present, care must be exercised to
prevent the removal of particles attracted by a leakage field that
may prove to be a relevant indication of a discontinuity.
15.1.4 Near-surface Discontinuities Powder Patterns—In
order to recognize the broad, fuzzy, weakly held powder
patterns produced by near-surface discontinuities, it is essential
to observe carefully the formation of indications while the
powder is being applied and also while the excess is being
removed. Sufficient time for indication formation and exami-
nation should be allowed between successive magnetization
cycles.
15.2 Wet Particle Application—Wet magnetic particles,
fluorescent or nonfluorescent, suspended in a vehicle at a
recommended concentration may be applied either by spraying
or flowing over the areas to be inspected during the application
of the magnetizing field current (continuous technique) or after
turning off the current (residual technique). Proper sequencing
of operation (part magnetization and timing of bath applica-
tion) is essential to indication formation and retention. For the
continuous technique multiple current shots should be applied.
The last shot should be applied after the particle flow has been
diverted and while the particle bath is still on the part. A single
shot may be sufficient. Care should be taken to prevent damage
to a part due to overheating or other causes. Since fine or
weakly held indications on highly finished or polished surfaces
may be washed away or obliterated, care must be taken to
prevent high-velocity flow over critical surfaces and to cut off
the bath application before removing the magnetic field. Since
a residual field has a lower intensity than a continuous field,
less pronounced indications tend to form.
15.3 Magnetic Slurry/Paints—Magnetic slurry/paints are
applied to the part with a brush before or during part magne-
tization. Indications appear as a dark line against a light silvery
background. Magnetic slurry is ideal for overhead or under-
water magnetic particle examination.
15.4 Magnetic Polymers—Magnetic polymers are applied
to the test part as a liquid polymer suspension. The part is then
magnetized, the polymer is allowed to cure, and the elastic
coating is removed from the test surface for examination. Care
must be exercised to ensure that magnetization is completed
within the active migration period of the polymer which is
usually about 10 min. This method is particularly applicable to
areas of limited visual access such as bolt holes. Detailed
application and use instructions of the manufacturer should be
followed for optimum results.
16. Interpretation of Indications
16.1 Valid Indications—All valid indications formed by
magnetic particle examination are the result of magnetic
leakage fields. Indications may be relevant (16.1.1), nonrel-
evant (16.1.2), or false (16.1.3).
16.1.1 Relevant Indications—Relevant indications are pro-
duced by leakage fields which are the result of discontinuities.
Relevant indications require evaluation with regard to the
acceptance standards agreed upon between the manufacturer/
test agency and the purchaser (see Annex A1).
16.1.2 Nonrelevant Indications—Nonrelevant indications
can occur singly or in patterns as a result of leakage fields
created by conditions that require no evaluation such as
changes in section (like keyways and drilled holes), inherent
material properties (like the edge of a bimetallic weld),
magnetic writing, etc.
16.1.3 False Indications—False indications are not the
result of magnetic forces. Examples are particles held mechani-
cally or by gravity in shallow depressions or particles held by
rust or scale on the surface.
17. Recording of Indications
17.1 Means of Recording—When required by a written
procedure, permanent records of the location, type, direction,
length(s), and spacing(s) of indications may be made by one or
more of the following means.
17.1.1 Sketches—Sketching the indication(s) and their loca-
tions.
17.1.2 Transfer (Dry Powder Only)—Covering the indica-
tion(s) with transparent adhesive-backed tape, removing the
tape with the magnetic particle indication(s) adhering to it, and
placing it on paper or other appropriate background material
indicating locations.
17.1.3 Strippable Film (Dry Powder Only)—Covering the
indication(s) with a spray-on strippable film that fixes the
indication(s) in place. When the film is stripped from the part,
the magnetic particle indication(s) adhere to it.
17.1.4 Photographing—Photographing the indications
themselves, the tape, or the strippable film reproductions of the
indications.
17.1.5 Written Records—Recording the location, length,
orientation, and number of indications.
17.2 Accompanying Information—A record of the proce-
dure parameters listed below as applicable should accompany
the inspection results:
E 709
17
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
17.2.1 Method Used—Magnetic particle method (dry, wet,
fluorescent, etc.).
17.2.2 Magnetizing Technique—Magnetizing technique
(continuous, true-continuous, residual).
17.2.3 Current Type—Magnetizing current (AC, half-wave
rectified or full-wave rectified AC, etc.).
17.2.4 Field Direction—Direction of magnetic field (prod
placement, cable wrap sequence, etc.).
17.2.5 Field Strength—Magnetic current strength (ampere
turns, amperes per millimetre (inch) of prod spacing, lifting
force, etc.).
18. Demagnetization
18.1 Applicability—All ferromagnetic material will retain
some residual magnetism, the strength of which is dependent
on the retentivity of the part. Residual magnetism does not
affect the mechanical properties of the part. However, a
residual field may cause chips, filing, scale, etc. to adhere to the
surface affecting subsequent machining operations, painting, or
plating. Additionally, if the part will be used in locations near
sensitive instruments, high residual fields could affect the
operation of these instruments. Furthermore, a strong residual
magnetic field in a part to be arc welded could interfere with
welding. Residual fields may also interfere with later magnetic
particle examination. Demagnetization is required only if
specified in the drawings, specification, or purchase order.
When required, an acceptable level of residual magnetization
and the measuring method shall also be specified. See 18.3.
18.2 Demagnetization Methods—The ease of demagnetiza-
tion is dependent on the coercive force of the metal. High
retentivity is not necessarily related to high coercive force in
that the strength of the residual field is not always an indicator
of ease of demagnetizing. In general, demagnetization is
accomplished by subjecting the part to a field equal to or
greater than that used to magnetize the part and in nearly the
same direction, then continuously reversing the field direction
while gradually decreasing it to zero.
18.2.1 Withdrawal from Alternating Current Coil—The
fastest and most simple technique is to pass the part through a
high intensity alternating current coil and then slowly withdraw
the part from the field of the coil. A coil of 5000 to 10 000
ampere turns is recommended. Line frequency is usually from
50 to 60 Hz alternating current. The piece should enter the coil
from a 12-in. (300-mm) distance and move through it steadily
and slowly until the piece is at least 36 in. (900 mm) beyond
the coil. Care should be exercised to ensure that the part is
entirely removed from the influence of the coil before the
demagnetizing force is discontinued, otherwise the demagne-
tizer may have the reverse effect of magnetizing the part. This
should be repeated as necessary to reduce the residual field to
an acceptable level. See 18.3. Small parts of complex figura-
tion can be rotated and tumbled while passing through the field
of the coil.
18.2.2 Decreasing Alternating Current—An alternative
technique for part demagnetization is subjecting the part to the
field while gradually reducing its strength to a desired level.
18.2.3 Demagnetizing With Yokes—Alternating current
yokes may be used for local demagnetization by placing the
poles on the surface, moving them around the area, and slowly
withdrawing the yoke while it is still energized.
18.2.4 Reversing Direct Current—The part to be demagne-
tized is subjected to consecutive steps of reversed and reduced
direct current magnetization to a desired level. (This is the
most effective process of demagnetizing large parts in which
the alternating current field has insufficient penetration to
remove the internal residual magnetization.) This technique
requires special equipment for reversing the current while
simultaneously reducing it in small increments.
18.3 Extent of Demagnetization—The effectiveness of the
demagnetizing operation can be indicated by the use of
appropriate magnetic field indicators or field strength meters.
Caution: A part may retain a strong residual field after having
been circularly magnetized and exhibit little or no external
evidence of this field. Therefore, the circular magnetization
should be conducted before longitudinal magnetization if
complete demagnetization is required.
18.3.1 After demagnetization residual fields should not
exceed 3 G (240 Am−1
) anywhere in the piece, absolute value,
unless otherwise agreed upon or as specified on the engineering
drawing or in the contract, purchase order, or specification.
19. Post Examination Cleaning
19.1 Particle Removal—Post-test cleaning is necessary
where magnetic particle material(s) could interfere with sub-
sequent processing or with service requirements. The pur-
chaser should specify when post-test cleaning is needed and the
extent required.
19.2 Means of Particle Removal—Typical post-test clean-
ing techniques employed are: (a) the use of compressed air to
blow off unwanted dry magnetic particles; (b) drying of wet
particles and subsequent removal by brushing or with com-
pressed air; (c) removal of wet particles by flushing with
solvent; and (d) other suitable post-examination cleaning
techniques may be used if they will not interfere with subse-
quent requirements.
20. Evaluation of System Performance/Sensitivity
20.1 Contributing Factors—The overall performance/
sensitivity of a magnetic particle examination system is depen-
dent upon the following:
20.1.1 Operator capability, if a manual operation is in-
volved.
20.1.2 Control of process steps.
20.1.3 The particles or suspension, or both.
20.1.4 The equipment.
20.1.5 Visible light level.
20.1.6 Black light monitoring where applicable.
20.1.7 Magnetic field strength.
20.1.8 Field direction or orientation.
20.1.9 Residual field strength.
20.1.10 These factors should all be controlled individually.
20.2 Maintenance and Calibration of Equipment—The
magnetic particle equipment employed should be maintained in
proper working order at all times. The frequency of verification
calibration, usually every six months, see Table 2, or whenever
a malfunction is suspected, should be specified in the written
procedures of the testing facility. Records of the checks and
results provide useful information for quality control purposes
E 709
18
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
and should be maintained. In addition, any or all of the tests
described should be performed whenever a malfunction of the
system is suspected. Calibration tests should be conducted in
accordance with the specifications or documents that are
applicable.
20.3 Equipment Checks—The following tests are recom-
mended for ensuring the accuracy of magnetic particle mag-
netizing equipment.
20.3.1 Ammeter Accuracy—The equipment meter readings
should be compared to those of a control test meter incorpo-
rating a shunt or current transformer connected to monitor the
output current. The accuracy of the entire control test meter
arrangement should be verified at six-month intervals or as
agreed upon between the purchaser and supplier by a means
traceable to the National Institute of Standards and Technology
(NIST). Comparative readings shall be taken at a minimum of
three output levels encompassing the usable range. The equip-
ment meter reading shall not deviate by more than6 10 % of
full scale relative to the actual current values as shown by the
test meter. Caution: When measuring half-wave rectified AC,
the direct current reading of a conventional DC test meter
reading must be doubled.
20.3.2 Timer Control Check—On equipment utilizing a
timer to control the duration of the current flow, the timer
should be checked for accuracy as specified in Table 2 or
whenever a malfunction is suspected.
20.3.3 Magnetic Field Quick Break Check—On equipment
that has a quick break feature, the functioning of this circuit
should be checked and verified. This test may be performed
using a suitable oscilloscope or a simple test device usually
available from the manufacturer. On electronic power packs or
machines, failure to achieve indication of a“ quick break”
would indicate that a malfunction exists in the energizing
circuit.
20.3.4 Equipment Current Output Check—To ensure the
continued accuracy of the equipment, ammeter readings at
each transformer tap should be made with a calibrated
ammeter-shunt combination. This accessory is placed in series
with the contacts. The equipment shunt should not be used to
check the machine of which it is a part. For infinite current
control units (non-tap switch), settings at 500-A intervals
should be used. Variations exceeding 610 % from the equip-
ment ammeter readings indicate the equipment needs service or
repair.
20.3.5 Internal Short Circuit Check—Magnetic particle
equipment should be checked periodically for internal short
circuiting. With the equipment set for maximum amperage
output, any deflection of the ammeter when the current is
activated with no conductor between the contacts is an indica-
tion of an internal short circuit.
20.3.6 Electromagnetic Yoke Lifting Force Test—The mag-
netizing force of a yoke (or a permanent magnet) should be
tested by determining its lifting power on a steel plate. See
Table 3. The lifting force relates to the electromagnetic strength
of the yoke.
20.3.7 Powder Blower—The performance of powder blow-
ers used to apply the dry magnetic particles should be checked
at routine intervals or whenever a malfunction is suspected.
The check should be made on a representative test part. The
blower should coat the area under test with a light, uniform
dust-like coating of dry magnetic particles and have sufficient
force to remove the excess particles without disturbing those
particles that are evidence of indications. Necessary adjust-
ments to the blower’s flow rate or air velocity should be made
in accordance with the manufacturer’s recommendations.
20.4 Examination Area Light Level Control:
20.4.1 Visible Light Intensity—Light intensity in the exami-
nation area should be checked at specified intervals with the
designated light meter at the surface of the parts being
examined. See Table 2.
20.4.2 Black (ultraviolet) Light Intensity—Black light in-
tensity and wavelength should be checked at the specified
intervals but not to exceed one-week intervals and whenever a
bulb is changed. Reflectors and filters should be cleaned daily
and checked for integrity. See Table 2. Cracked or broken UV
filters shall be replaced immediately. Defective bulbs which
radiate UV energy must also be replaced before further use.
20.5 Dry Particle Quality Control Tests—In order to assure
uniform and consistent performance from the dry magnetic
powder selected for use, it is advisable that all incoming
powders be certified or tested for conformance with quality
control standards established between the user and supplier.
20.5.1 Contamination:
20.5.1.1 Degradation Factors—Dry magnetic particles are
generally very rugged and perform with a high degree of
consistency over a wide process envelope. Their performance,
however, is susceptible to degradation from such contaminants
as moisture, grease, oil, rust and mill scale particles, nonmag-
netic particles such as foundry sand, and excessive heat. These
contaminants will usually manifest themselves in the form of
particle color change and particle agglomeration, the degree of
TABLE 2 Recommended Verification Intervals
Item
Maximum Time
Between
VerificationsA
Reference
Paragraphs
Lighting:
Visible light intensity 1 week 7.1.1
Black light intensity 1 week 7.1.2
Background visible light intensity 1 weekA
7.1.1
System performance using test piece or
ring specimen of Fig. 17
1 day 20.8.3
Wet particle concentration 8 h, or every shift
change
20.6
Wet particle contamination 1 week 20.6.4
Water break test 1 day 20.7.5
Equipment calibration/check:
Ammeter accuracy 6 months 20.3.1
Timer control 6 months 20.3.2
Quick break 6 months 20.3.3
Dead weight check 6 months 20.3.6
Light meter checks 6 months 20.4
A
Note—The maximum time between verifications may be extended when
substantiated by actual technical stablity/reliability data.
TABLE 3 Minimum Yoke Lifting Force
Type
Current
Yoke Pole Leg Spacing
50 to 100 mm
(2 to 4 in.)
100 to 150 mm
(4 to 6 in.)
AC
DC
45 N (10 lb)
135 N (30 lb)
225 N (50 lb)
E 709
19
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
which will determine further use of the powder. Over-heated
dry particles can lose their color, thereby reducing the color
contrast with the part and thus hinder part examination. Particle
agglomeration can reduce particle mobility during processing,
and large particle agglomerates may not be retained at an
indication.
20.5.1.2 Ensuring Particle Quality—To ensure against del-
eterious effects from possible contaminants, it is recommended
that a routine performance/sensitivity test be conducted (see
20.8.3).
20.6 Wet Particle Quality Control Tests—The following
tests for wet magnetic particle suspensions should be con-
ducted at startup and at regular intervals to assure consistent
performance. See Table 2. Since bath contamination will occur
as the bath is used, monitoring the working bath at regular
intervals is essential.
20.6.1 Determining Bath Concentration—Bath concentra-
tion and sometimes bath contamination are determined by
measuring its settling volume through the use of a Test Method
D 1966 pear-shaped centrifuge tube with a 1-mL stem
(0.05-mL divisions) for fluorescent particle suspensions or a
1.5-mL stem (0.1-mL divisions) for nonfluorescent suspen-
sions. Before sampling, the suspension should be run through
the recirculating system for at least 30 min to ensure thorough
mixing of all particles which could have settled on the sump
screen and along the sides or bottom of the tank. Take a
100-mL portion of the suspension from the hose or nozzle,
demagnetize and allow it to settle for approximately 60 min
with petroleum distillate suspensions or 30 min with water-
based suspensions before reading. The volume settling out at
the bottom of the tube is indicative of the particle concentration
in the bath.
20.6.2 Sample Interpretation—If the bath concentration is
low in particle content, add a sufficient amount of particle
materials to obtain the desired concentration; if the suspension
is high in particle content, add sufficient vehicle to obtain the
desired concentration. If the settled particles appear to be loose
agglomerates rather than a solid layer, take a second sample. If
still agglomerated, the particles may have become magnetized;
replace the suspension.
20.6.3 Settling Volumes—For fluorescent particles, the rec-
ommended settling volume (see 15.2) is from 0.1 to 0.4 mL in
a 100-mL bath sample and from 1.2 to 2.4 mL per 100 mL of
vehicle for non-fluorescent particles, unless otherwise ap-
proved by the Cognizant Engineering Organization (CEO).
Refer to appropriate AMS document (3041, 3042, 3043, 3044,
3045, and/or 3046). For dual-colored particles, the recom-
mended settling volume should be determined by the perfor-
mance requirements and lighting environment of a given
application as recommended by the manufacturer. See 8.5.5.
20.6.4 Bath Contamination—Both fluorescent and nonfluo-
rescent suspensions should be checked periodically for con-
taminants such as dirt, scale, oil, lint, loose fluorescent pig-
ment, water (in the case of oil suspensions), and particle
agglomerates which can adversely affect the performance of
the magnetic particle examination process. See Table 2.
20.6.4.1 Carrier Contamination—For fluorescent baths, the
liquid directly above the precipitate should be examined with
black light. The liquid will have a little fluorescence. Its color
can be compared with a freshly made-up sample using the
same materials or with an unused sample from the original bath
that was retained for this purpose. If the “used” sample is
noticeably more fluorescent than the comparison standard, the
bath should be replaced.
20.6.4.2 Particle Contamination—The graduated portion of
the tube should be examined under black light if the bath is
fluorescent and under visible light (for both fluorescent and
nonfluorescent particles) for striations or bands, differences in
color or appearance. Bands or striations may indicate contami-
nation. If the total volume of the contaminates, including bands
or striations exceeds 30 % of the volume of magnetic particles,
or if the liquid is noticeably fluorescent (see 20.6.4.1), the bath
should be replaced.
20.6.5 Particle Durability—The durability of both the fluo-
rescent and nonfluorescent magnetic particles in suspension
should be checked periodically to ensure that the particles have
not degraded due to chemical attack from the suspending oil or
conditioned water vehicles or mechanically degraded by the
rotational forces of the recirculating pump in a wet horizontal
magnetic particle unit. Fluorescent magnetic particle break-
down in particular can result in a decrease in sensitivity and an
increase in nonmagnetic fluorescent background. Lost fluores-
cent pigment can produce false indications that can interfere
with the examination process.
20.6.6 Fluorescent Brightness—It is important that the
brightness of fluorescent magnetic particle powder be main-
tained at the established level so that indication and back-
ground brightness can be kept at a relatively constant level.
Variations in contrast can noticeably affect test results. Lack of
adequate contrast is generally caused by:
20.6.6.1 An increase in contamination level of the vehicle
increasing background fluorescence, or
20.6.6.2 Loss of vehicle because of evaporation, increasing
concentration, or
20.6.6.3 Degradation of fluorescent particles. A change in
contrast ratio can be observed by using a test ring specimen
with an etched surface.
20.6.7 Performance/Sensitivity—Failure to find a known
discontinuity in a part or obtain the specified indications on the
test ring (see 20.8.3) indicates a need for changing of the entire
bath. If a part was used, it must have been ultrasonically
cleaned so that no fluorescent background can be detected
when viewed under black light with a surface intensity of at
least 1000 µW/cm2
. If any background is noted that interferes
with either detection or interpretation, the bath should be
drained and a new suspension made.
20.6.8 Magnetic Stripe Cards—The encoded pattern on the
magnetic stripes of magnetic stripe cards may serve as a test
piece for the evaluation of particle sensitivity. Particles are
attracted to magnetic gradients formed when the stripe has
been encoded. See Appendix X2 for further information.
20.7 Bath Characteristics Control:
20.7.1 Oil Bath Fluids—Properties of oil-bath fluids are
described in AMS 2641 or A-A–59230.
20.7.2 Water Bath Fluids—Properties of conditioned water-
bath fluids are described in AS 4792.
E 709
20
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
20.7.3 Viscosity—The viscosity of the suspension should
not exceed 5 mm2
/s (5.0 cSt), at any temperature at which the
bath may be used, when tested in accordance with Test Method
D 445.
20.7.4 Flash Point—The flash point of wet magnetic par-
ticle light petroleum distillate suspension should be a minimum
of 200°F (93°C); use Test Method D 93.
20.7.5 Water Break Test for Conditioned Water Vehicles—
Properly conditioned water will provide proper wetting, par-
ticle dispersion, and corrosion protection. The water break test
should be performed by flooding a part, similar in surface
finish to those under test, with suspension, and then noting the
appearance of the surface of the part after the flooding is
stopped. If the film of suspension is continuous and even all
over the part, sufficient wetting agent is present. If the film of
suspension breaks, exposing bare surfaces of the part, and the
suspension forms many separate droplets on the surface, more
wetting agent is needed or the part has not been sufficiently
cleaned.
20.7.6 pH of Conditioned Water Vehicles—The pH of the
conditioned water bath should be between 7.0 and 10.5 as
determined by a suitable pH meter or special pH paper.
20.8 Verifying System Performance:
System performance tests must be conducted in accordance
with a written procedure so that the test is performed in the
same manner each time.
20.8.1 Production Test Parts with Discontinuities—A prac-
tical way to evaluate the performance and sensitivity of the dry
or wet magnetic particles or overall system performance, or
both, is to use representative test parts with known disconti-
nuities of the type and severity normally encountered during
actual production inspection. However, the usefulness of such
parts is limited because the orientation and magnitude of the
discontinuities cannot be controlled. The use of flawed parts
with gross discontinuities is not recommended. Caution—If
such parts are used, they must be thoroughly cleaned and
demagnetized after each use.
20.8.2 Fabricated Test Parts with Discontinuities—Often,
production test parts with known discontinuities of the type and
severity needed for evaluation are not available. As an alter-
native, fabricated test specimens with discontinuities of vary-
ing degree and severity can be used to provide an indication of
the effectiveness of the dry or wet magnetic particle examina-
tion process.
20.8.3 Test Plate—A magnetic particle system performance
test plate, such as shown in Fig. 17 is useful for testing the
overall performance of wet or dry techniques using prods and
yokes. Recommended minimum dimensions are ten inches per
side and nominal thickness of one inch. Discontinuities can be
formed by controlled heating/cooling, EDM notches, artificial
discontinuities per 14.2.2 or other means.
NOTE 2—Notches are to be filled flush to the surface with a noncon-
ducting material, such as epoxy, to prevent the mechanical holding of the
indicating medium.
20.8.4 Test Ring Specimen—A test (Ketos) ring specimen
may also be used in evaluating and comparing the overall
performance and sensitivity of both dry and wet, fluorescent
and non-fluorescent magnetic particle techniques using a
central conductor magnetization technique. Refer to Practice
E 1444, Appendix X1.
20.8.4.1 Using the Test Ring—If using the test ring, place a
conductor with a diameter between 1 and 1.25 in. (25 and 31
mm) and a length longer than 16 in. (40 cm) through the center
of the ring. Center the ring on the length of the conductor.
Magnetize the ring circularly by passing the current through
the conductor as described in Appendix X1 of Practice E 1444.
Gently apply particles to the surface of the ring while the
current is flowing. Examine the ring within one minute after
current application. The number of hole indications visible
should meet or exceed those as specified in Appendix X1 of
Practice E 1444.
20.8.5 Magnetic Field Indicators:
20.8.5.1 “Pie” Field Indicator—The magnetic field indica-
tor shown in Fig. 15 relies on the slots between the pie shaped
segments to show the presence and the approximate direction
of the magnetic field. A suitable field strength is indicated when
a clearly defined line of magnetic particles forms across the
copper face of the indicator (the slots are against the piece)
when the magnetic particles are applied simultaneously with
the magnetizing force. Failure to obtain an indication can result
from: (1) insufficient magnetic field, or (2) the magnetic
properties of the material being examined, or both.
20.8.5.2 Slotted Shims—Several types of slotted shims ex-
ist. Refer to AS 5371 and to illustrations in Appendix X1.
20.8.6 Half-effect Probe—The Hall-effect probe or sensor
measures the tangential field strength (in air adjacent to the
part) of the magnetizing force (H) and is calibrated in gauss.
The sensor must be used with care. It must be kept close to the
part surface. The manufacturer’s instructions should be fol-
lowed. These instruments can be used to detect a residual field
or measure fields produced during head shots and shots using
a central conductor.
21. Procedures
21.1 When specified a procedure should be written for all
FIG. 17 Sample of a Magnetic Particle Performance Test Plate.
Defects are formed and located in accordance with plate
manufacturers’ specifications.
E 709
21
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
magnetic particle examinations and should include as a mini-
mum the following information. A sketch is usually used for
illustrating part geometry, techniques, and areas for examina-
tion. This sketch may also be used for recording location of
magnetic field indicators and for recording location of discon-
tinuities.
21.1.1 Area to be examined (entire part or specific area),
21.1.2 Type of magnetic particle material (dry or wet,
visible or fluorescent),
21.1.3 Magnetic particle equipment,
21.1.4 Part surface preparation requirements,
21.1.5 Magnetizing process (continuous, true-continuous,
residual),
21.1.6 Magnetizing current (alternating, half-wave rectified
AC, full-wave rectified AC, direct),
21.1.7 Means of establishing part magnetization (direct-
prods, head/tailstock contact or cable wrap, indirect-coil/cable
wrap, yoke, central conductor, and so forth),
21.1.8 Direction of magnetic field (circular or longitudinal),
21.1.9 System performance/sensitivity checks,
21.1.10 Magnetic field strength (ampere turns, field density,
magnetizing force, and number and duration of application of
magnetizing current),
21.1.11 Application of examination media,
21.1.12 Interpretation and evaluation of indications,
21.1.13 Type of records including accept/reject criteria,
21.1.14 Demagnetizing techniques, if required, and
21.1.15 Post-examination cleaning, if required,
21.2 Written Reports—Written reports shall be prepared as
agreed upon between the testing agency/department and the
purchaser/user.
22. Acceptance Standards
22.1 The acceptability of parts examined by this method is
not specified herein. Acceptance standards are a matter of
agreement between the manufacturer and the purchaser and
should be stated in a referenced contract, specification, or code.
23. Safety
23.1 Those involved with hands-on magnetic particle ex-
amination exposure to hazards include:
23.1.1 Electric Shock and Burns—Electric short circuits can
cause shock and particularly burns from the high amperages at
relatively low voltages that are used. Equipment handling
water suspensions should have good electrical grounds.
23.1.2 Flying Particles—Magnetic particles, particularly
the dry ones, dirt, foundry sand, rust, and mill scale can enter
the eyes and ears when they are blown off the part when
applying them to a vertical or overhead surface or when
cleaning an examined surface with compressed air. Dry par-
ticles are easy to inhale and the use of a dust respirator is
recommended.
23.1.3 Falls—A fall from a scaffold or ladder if working on
a large structure in the field or shop.
23.1.4 Fire—Ignition of a petroleum distillate bath.
23.1.5 Environment—Doing magnetic particle examination
where flammable vapors are present as in a petrochemical plant
or oil refinery. Underwater work has its own set of hazards.
23.1.6 Wet Floors—Slipping on a floor wetted with a
particle suspension.
23.1.7 Shifting or Dropping of Large Components—Large
components, especially those on temporary supports can shift
during examination or fall while being lifted. In addition,
operators should be alert to the possibility of injury to body
members being caught beneath a sling/chain or between
head/tail stock and the piece.
23.1.8 Ultraviolet Light Exposure—Ultraviolet light can
adversely affect the eyes and skin. Safety goggles designed to
absorb UV wavelength radiation are suggested where high
intensity blacklight is used.
23.1.9 Materials and Concentrates—The safe handling of
magnetic particles and concentrates are governed by the
supplier’s Material Safety Data Sheets (MSDS). The MSDS
conforming to 29 CFR 1910.1200 or equivalent must be
provided by the supplier to any user and must be prepared in
accordance with FED-STD-313.
24. Precision and Bias
24.1 The methodology described in the practice will pro-
duce repeatable results provided:
24.1.1 The strength of the magnetic flux field in the part/
piece is confirmed and,
24.1.2 The field has the proper orientation with respect to
the discontinuities being sought.
24.2 It must be recognized that the surface condition of the
material being examined, the material’s magnetic properties,
its shape, and control of the factors listed in 20.1 influence the
results obtained.
25. Keywords
25.1 dye; evaluation; examination; fluorescent; inspection;
magnetic particle; nondestructive; testing
E 709
22
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
ANNEX
(Mandatory Information)
A1. TYPICAL MAGNETIC PARTICLE INDICATIONS
A1.1 Surface discontinuities with few exceptions produce
sharp and distinct magnetic particle indications. Near-surface
discontinuities on the other hand produce less distinct or fuzzy
magnetic particle indications in comparison to surface discon-
tinuities; the magnetic particle indications are broad rather than
sharp and the particles are less tightly held.
A1.2 Wet Method:
A1.2.1 Fluorescent—Indications of surface cracks, surface
indications, and an indication of a near surface discontinuity
are shown in Figs. A1.1-A1.6.
FIG. A1.1 Indications of Surface Cracks (Produced by Central Conductor DC Magnetization)
E 709
23
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
A1.2.2 Nonfluorescent—Indications of surface cracks are
shown in Figs. A1.7-A1.16.
A1.3 Dry Method—Indications of surface cracks are shown
in Figs. A1.17-A1.23.
A1.4 Nonrelevant indications are shown in Figs. A1.24-
A1.26.
FIG. A1.2 Indications of Surface Cracks (Produced by Central Conductor DC Magnetization)
FIG. A1.3 Indications of Surface Cracks (Produced by Central
Conductor DC Magnetization)
E 709
24
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
FIG. A1.4 Surface Indications (Produced by Central Conductor DC Magnetization)
FIG. A1.5 Indications of Surface Cracks (Produced by Circular
Magnetization DC Continuous)
E 709
25
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
FIG. A1.6 Indication of a Near-Surface Discontinuity (Produced
by Prod Magnetization)
FIG. A1.7 Indications of Surface Cracking (Produced by Central Conductor Magnetization DC Continuous)
E 709
26
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
FIG. A1.8 Indications of Surface Cracking (Produced by Circular Direct Magnetization DC Continuous)
FIG. A1.9 Indications of Surface Cracks (Produced by Central
Conductor Magnetization DC Continuous)
E 709
27
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
FIG. A1.10 Indications of Surface Cracks (Produced by Circular Indirect Magnetization DC)
FIG. A1.11 Indications of a Near-Surface Discontinuity (Produced
by Circular Direct Magnetization AC Continuous)
E 709
28
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
FIG. A1.12 Indications of Near-Surface Indications (Produced by
Circular Direct Magnetization AC Continuous)
FIG. A1.13 Magnetic Rubber Indications of Surface Cracks in
Aircraft Fastener Holes (Produced by Yoke Magnetization DC
Continuous)
FIG. A1.14 Magnetic Rubber Indications of Surface Cracks in
Aircraft Fastener Holes (Produced by Yoke Magnetization DC
Continuous)
E 709
29
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
FIG. A1.15 Magnetic Slurry Indications of Surface Cracks in Weldment (Produced by Yoke Magnetization, AC Continuous)
FIG. A1.16 Magnetic Slurry Indications of Surface Cracks (Produced by Yoke Magnetization, AC Continuous)
E 709
30
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
FIG. A1.17 Indications of a Near-Surface Discontinuity (Produced by Prod Magnetization, HWDC Continuous)
FIG. A1.18 Indications of a Near-Surface Discontinuity (Produced by Prod Magnetization, HWDC Continuous)
FIG. A1.19 Indication of Surface Cracks (Produced by Circular
Indirect Magnetization, AC Continuous)
E 709
31
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
FIG. A1.20 Indication of Surface Cracks (Produced by Prod
Magnetization, AC Continuous)
FIG. A1.21 Indications of Surface Cracks (Produced by Prod Magnetization, DC Continuous)
E 709
32
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
FIG. A1.22 Indications of Surface Cracks (Produced by Circular
Direct Magnetization, AC Continuous)
FIG. A1.23 Indications of Surface Cracks (Produced by Central
Conductor Magnetization, AC Continuous)
E 709
33
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
FIG. A1.24 Nonrelevant Indications of Magnetic Writing
(Produced by Direct Magnetization, DC Continuous)
FIG. A1.25 Nonrelevant Indications Due to Change in Section on
a Small Part (Produced by Indirect, Circular Magnetization, DC
Continuous)
E 709
34
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
APPENDIXES
(Nonmandatory Information)
X1. REFERENCE STANDARD NOTCHED SHIMS FOR MAGNETIC PARTICLE EXAMINATION PER AS 5371
X1.1 The following standard flawed shims are typically
used to establish proper field direction and ensure adequate
field strength during technique development in magnetic par-
ticle examination. The shims of Fig. X1.1 may be used to
ensure the establishment and balance of fields in the multidi-
rectional magnetization method.
X1.1.1 The shims are available in two thicknesses, 0.002 in.
(0.05 mm) and 0.004 in. (0.10 mm). Thinner shims are used
when the thicker shims cannot conform to the part surface in
the area of interest.
X1.1.2 The shims are available in two sizes, 0.75 in. (19
mm) square for Figs. X1.1 and X1.2 and 0.79 in. (20 mm)
square of Fig. X1.3. The shims of Fig. X1.3 are cut, by the user,
into four 0.395 in. (10 mm) square shims for use in restricted
areas.
X1.1.3 Shims shall be low carbon steel, AMS 5062 or
equivalent.
X1.1.4 Shims shall be used as specified in AS 5371. Shims
are placed in the area(s) of interest with notches toward the
surface of the part being examined. Use enough shims or place
the shims in multiple areas to ensure proper field directions and
strengths are obtained.
FIG. A1.26 Nonrelevant Indications of Junction Between Dissimilar Materials (Produced by Coil DC Residual Magnetization)
FIG. X1.1 Shim Thicknesses for Shim Types 3C2–234 and 3C4–234
E 709
35
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
X2. DEVICES FOR EVALUATION OF MAGNETIC PARTICLE EXAMINATION MATERIALS
X2.1 Scope
X2.1.1 The purpose of this appendix is to describe the
capabilities and use of various devices that may be utilized to
monitor and evaluate the performance of materials and systems
for magnetic particle examination.
X2.2 Magnetic Stripe Cards. The magnetically encoded
pattern in magnetic stripes, as on cards used for personal
banking, identification and other purposes, can serve as a tool
to evaluate magnetic particle inspection materials. Particles are
attracted to the magnetic gradients formed in the stripe when
the stripe has been magnetically encoded with a pattern of flux
reversals. The encoding of the stripe can be controlled to
provide gradients of varying magnitude. Particles can be
evaluated for sensitivity when observed to see how small a
gradient can generate a particle indication.
X2.3 Characteristics
X2.3.1 Magnetic stripe cards shall be made in accordance
with ISO 7810– Identification Cards— Physical Characteris-
tics.
X2.3.2 The stripe may be made of either low-coercivity
(lo-co) or high-coercivity (hi-co) material, as designated by the
manufacturer.
X2.3.3 A constant encoding pattern, decaying encoding
pattern, reverse decaying pattern or other pattern may be
encoded into the stripe. See Fig. X2.1 photograph of fluores-
cent particle indications of decaying and reverse decaying
encoding patterns.
FIG. X1.2 Shim Types CX-230 and CX-430
FIG. X1.3 Shim Thicknesses for Shim Types CX4–230 and CX4–430
E 709
36
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
X2.4 Use of the Magnetic Stripe Card for Magnetic
Particle Material Evaluation
X2.4.1 Wet Method Materials—Wet method materials may
be poured, sprayed or otherwise applied to the stripe, as they
would be used for MPI. Excess bath shall be allowed to flow
away from the stripe. The stripe shall be observed under
suitable illumination (See Section 7) for the formation of
particle indications. Observations shall be noted as to the
quantity of particle indications and the clarity thereof.
NOTE X2.1—Dark colored non-fluorescent particles may be more
readily observed with the use of a white contrast paint applied over the
stripe prior to particle evaluation. Particle indications may also be
observed and/or permanently recorded per Section 17 (Paragraph 17.1.2
can apply to wet method powder after the fluid has been allowed to
evaporate.).
X2.4.2 Dry Method Materials—Dry method materials shall
be poured, dusted, blown or otherwise applied to the stripe, as
they would be used for MPI. Excess powder shall be removed
with a gentle blowing action. The stripe shall be observed
under suitable illumination (See Section 7) for the formation of
particle indications. Observations shall be noted as to the
quantity of particle indications and the clarity therof. Refer to
Note X2.1 for dark colored particles.
X2.4.3 Recording of Indications—Recorded particle indica-
tions (See 17.1.2) may serve as material documentation records
and standards for material performance. Other material, or the
same material at a later time, can be compared at any time to
the recorded standard.
X2.5 Loss of Indications on the Stripe—There are several
circumstances where particle indications may not be visible on
the magnetic stripe. When indications are not visible the
subject particles shall not be used for inspection unless
otherwise verified as being acceptable.
X2.5.1 Concentration—The subject wet method particles
may not have a sufficient level of concentration. In this case,
increase the concentration level of the bath and re-perform the
test until the particles demonstrate suitable performance.
X2.5.2 Sensitivity—The subject particles may not provide
necessary sensitivity. In this case, replace the material with a
suitably sensitive material and re-perform the test until the
particles demonstrate suitable performance.
X2.5.3 Erasure—The stripe has become magnetically
erased. In this case, no discernible particle indication will
appear. In this case, repeat the test with another card and/or
sensitivity test until the particles demonstrate suitable perfor-
mance. Either destroy the card with the de-encoded stripe or
report it to the manufacturer and follow the manufacturer’s
recommendations.
X2.6 Precautions
X2.6.1 Preparation—The surface of the stripe must be
clean of any fluid or foreign matter prior to the application of
the MPI material. The encoded stripe shall not be re-
magnetized in any manner prior to use or de-magnetized in any
manner following its use.
X2.6.2 Storage—The surface of the stripe should be
cleaned of remaining fluid and particles after the observations
of the MPI material have been made. When not in use, the card
should be stored away from excessive heat and strong magnetic
fields.
The American Society for Testing and Materials takes no position respecting the validity of any patent rights asserted in connection
with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such
patent rights, and the risk of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible
technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your
views known to the ASTM Committee on Standards, at the address shown below.
FIG. X2.1 Example of fluorescent particle indications of a
decaying encoding pattern (top track) and a reverse-decaying
pattern (bottom track) on the magnetic stripe of a magnetic
stripe card.
E 709
37
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
This standard is copyrighted by ASTM, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at
610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website (www.astm.org).
E 709
38
Copyright ASTM International
Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112
Not for Resale, 12/27/2005 22:27:47 MST
No reproduction or networking permitted without license from IHS
--`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---

More Related Content

PDF
Astm e 709 2015
PDF
ASTM E1444 Standard Practice for MT.pdf
PDF
Standard Operating Procedures Manual
PPTX
workplace Walk through survey-----hazard evalutaion
DOC
Job safety analysis
PDF
ASTM E709 01 STANDARD GUIDE mag part exam.pdf
PDF
ASTM-SE-709-Standard Practice for Magentic Particle testing.pdf
PPTX
Ndtm 2-mpt
Astm e 709 2015
ASTM E1444 Standard Practice for MT.pdf
Standard Operating Procedures Manual
workplace Walk through survey-----hazard evalutaion
Job safety analysis
ASTM E709 01 STANDARD GUIDE mag part exam.pdf
ASTM-SE-709-Standard Practice for Magentic Particle testing.pdf
Ndtm 2-mpt

Similar to ASTM E709 Standard Test Method For MT.pdf (20)

PDF
Magnetic Particle Inspection (MPI)- NDT
PDF
NDT 2.pdf 555555555555555555555555555555555555555555
PDF
Magnetic particle inspection
PPT
Magnetic Particle Testing
PPT
Magnetic Particle Testing presentation.ppt
PPTX
A Brief Presentation On Magnetic Particle Testing
PPT
Magnetic Particle Testing.ppt
PDF
Magnetic Particle Testing
PPT
Jason corminal 2
PPT
Magnetic Particle Inspection
PPTX
Mpt 2015
PPTX
Magnetic particle inspection test (NDT).
PPTX
A Primer on Magnetic Particle Inspection
PDF
MPI_ Magnetic Particle Inspection
PPT
Seminar.MAJor presentation for final project viva
PPTX
Unit-II MPI Non Destructive Testing of Materials
PPTX
MT NDT -Specific Questions booklet information
PPTX
L22 magnetic particle test
PDF
Catalogo de magnaflux de equipos y accesorios
Magnetic Particle Inspection (MPI)- NDT
NDT 2.pdf 555555555555555555555555555555555555555555
Magnetic particle inspection
Magnetic Particle Testing
Magnetic Particle Testing presentation.ppt
A Brief Presentation On Magnetic Particle Testing
Magnetic Particle Testing.ppt
Magnetic Particle Testing
Jason corminal 2
Magnetic Particle Inspection
Mpt 2015
Magnetic particle inspection test (NDT).
A Primer on Magnetic Particle Inspection
MPI_ Magnetic Particle Inspection
Seminar.MAJor presentation for final project viva
Unit-II MPI Non Destructive Testing of Materials
MT NDT -Specific Questions booklet information
L22 magnetic particle test
Catalogo de magnaflux de equipos y accesorios
Ad

More from Balkishan Dyavanapelly (11)

PDF
chapter_13_surface_areas volume_and_volumes.pdf
PDF
chapter_12_areas_related_to_book-circles.pdf
PDF
chapter_5_arithmetic_progressions book for
PDF
VA Mobius brochure vibration analysis book
PPTX
PDF
RT Guide.Barc L1.pdf
PPTX
ID Fan presentation 1.pptx
PPT
Welding_Proceses.ppt
PPT
Magnetic Particle new 2.ppt
PDF
Basic welding & NDT.pdf
PDF
Geit 10017 en-weldinspection rt interpretation-22-25
chapter_13_surface_areas volume_and_volumes.pdf
chapter_12_areas_related_to_book-circles.pdf
chapter_5_arithmetic_progressions book for
VA Mobius brochure vibration analysis book
RT Guide.Barc L1.pdf
ID Fan presentation 1.pptx
Welding_Proceses.ppt
Magnetic Particle new 2.ppt
Basic welding & NDT.pdf
Geit 10017 en-weldinspection rt interpretation-22-25
Ad

Recently uploaded (20)

PDF
First part_B-Image Processing - 1 of 2).pdf
PPTX
Software Engineering and software moduleing
PDF
Accra-Kumasi Expressway - Prefeasibility Report Volume 1 of 7.11.2018.pdf
PDF
Implantable Drug Delivery System_NDDS_BPHARMACY__SEM VII_PCI .pdf
PPTX
wireless networks, mobile computing.pptx
PPTX
ASME PCC-02 TRAINING -DESKTOP-NLE5HNP.pptx
PPTX
Graph Data Structures with Types, Traversals, Connectivity, and Real-Life App...
PDF
August -2025_Top10 Read_Articles_ijait.pdf
PPTX
Measurement Uncertainty and Measurement System analysis
PDF
Computer System Architecture 3rd Edition-M Morris Mano.pdf
PPTX
"Array and Linked List in Data Structures with Types, Operations, Implementat...
PPTX
AUTOMOTIVE ENGINE MANAGEMENT (MECHATRONICS).pptx
PPTX
Module 8- Technological and Communication Skills.pptx
PPTX
Chapter 2 -Technology and Enginerring Materials + Composites.pptx
PDF
UEFA_Embodied_Carbon_Emissions_Football_Infrastructure.pdf
PPTX
Chemical Technological Processes, Feasibility Study and Chemical Process Indu...
PDF
Artificial Superintelligence (ASI) Alliance Vision Paper.pdf
PPTX
Amdahl’s law is explained in the above power point presentations
PDF
Applications of Equal_Area_Criterion.pdf
PDF
LOW POWER CLASS AB SI POWER AMPLIFIER FOR WIRELESS MEDICAL SENSOR NETWORK
First part_B-Image Processing - 1 of 2).pdf
Software Engineering and software moduleing
Accra-Kumasi Expressway - Prefeasibility Report Volume 1 of 7.11.2018.pdf
Implantable Drug Delivery System_NDDS_BPHARMACY__SEM VII_PCI .pdf
wireless networks, mobile computing.pptx
ASME PCC-02 TRAINING -DESKTOP-NLE5HNP.pptx
Graph Data Structures with Types, Traversals, Connectivity, and Real-Life App...
August -2025_Top10 Read_Articles_ijait.pdf
Measurement Uncertainty and Measurement System analysis
Computer System Architecture 3rd Edition-M Morris Mano.pdf
"Array and Linked List in Data Structures with Types, Operations, Implementat...
AUTOMOTIVE ENGINE MANAGEMENT (MECHATRONICS).pptx
Module 8- Technological and Communication Skills.pptx
Chapter 2 -Technology and Enginerring Materials + Composites.pptx
UEFA_Embodied_Carbon_Emissions_Football_Infrastructure.pdf
Chemical Technological Processes, Feasibility Study and Chemical Process Indu...
Artificial Superintelligence (ASI) Alliance Vision Paper.pdf
Amdahl’s law is explained in the above power point presentations
Applications of Equal_Area_Criterion.pdf
LOW POWER CLASS AB SI POWER AMPLIFIER FOR WIRELESS MEDICAL SENSOR NETWORK

ASTM E709 Standard Test Method For MT.pdf

  • 1. ASTM-E709 ADOPTION NOTICE ASTM-E709, "EXAMINATION, MAGNETIC PARTICLE", was adopted on 09-JAN-80 for use by the Department of Defense (DoD). Proposed changes by DoD activities must be submitted to the DoD Adopting Activity: Army Research Laboratory Weapons and Materials Research Directorate, Attn: AMSRL-WM-M, Aberdeen Proving Ground, MD 21005-5069. Copies of this document may be purchased from the American Society for Testing and Materials 100 Barr Harbor Drive West Conshohocken, Pennsylvania, United States, 19428-2959. http://www.astm.org/ ____________________ Custodians: Adopting Activity: Army - MR Army - MR Navy - AS Air Force - 11 Reviewer Activities: Army - AR, AT, AV Navy - SH DLA - IS AREA NDTI DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 2. Designation: E 709 – 01 An American National Standard Standard Guide for Magnetic Particle Examination1 This standard is issued under the fixed designation E 709; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval. This standard has been approved for use by agencies of the Department of Defense. 1. Scope 1.1 This guide2 describes techniques for both dry and wet magnetic particle examination, a nondestructive method for detecting cracks and other discontinuities at or near the surface in ferromagnetic materials. Magnetic particle examination may be applied to raw material, semifinished material (billets, blooms, castings, and forgings), finished material and welds, regardless of heat treatment or lack thereof. It is useful for preventive maintenance examination. 1.1.1 This guide is intended as a reference to aid in the preparation of specifications/standards, procedures and tech- niques. 1.2 This guide is also a reference that may be used as follows: 1.2.1 To establish a means by which magnetic particle examination, procedures recommended or required by indi- vidual organizations, can be reviewed to evaluate their appli- cability and completeness. 1.2.2 To aid in the organization of the facilities and person- nel concerned in magnetic particle examination. 1.2.3 To aid in the preparation of procedures dealing with the examination of materials and parts. This guide describes magnetic particle examination techniques that are recom- mended for a great variety of sizes and shapes of ferromagnetic materials and widely varying examination requirements. Since there are many acceptable differences in both procedure and technique, the explicit requirements should be covered by a written procedure (see Section 21). 1.3 This guide does not indicate, suggest, or specify accep- tance standards for parts/pieces examined by these techniques. It should be pointed out, however, that after indications have been produced, they must be interpreted or classified and then evaluated. For this purpose there should be a separate code, specification, or a specific agreement to define the type, size, location, degree of alignment and spacing, area concentration, and orientation of indications that are unacceptable in a specific part versus those which need not be removed before part acceptance. Conditions where rework or repair are not permit- ted should be specified. 1.4 This guide describes the use of the following magnetic particle method techniques. 1.4.1 Dry magnetic powder (see 8.4), 1.4.2 Wet magnetic particle (see 8.5), 1.4.3 Magnetic slurry/paint magnetic particle (see 8.5.8), and 1.4.4 Polymer magnetic particle (see 8.5.8). 1.5 Personnel Qualification—Personnel performing exami- nations in accordance with this guide shall be qualified and certified in accordance with ASNT Recommended Practice No. SNT-TC-1A, ANSI/ASNT Standard CP-189, NAS 410, or as specified in the contract or purchase order. 1.6 Nondestructive Testing Agency—If a nondestructive testing agency as described in Practice E 543 is used to perform the examination, the testing agency shall meet the requirements of Practice E 543. 1.7 Table of Contents: SECTION Scope 1 Scope Description 1.1 A Reference Document 1.2 Acceptance Standards for Parts not Covered 1.3 Magnetic Particle Method Techniques 1.4 Personnel Qualifications 1.5 Nondestructive Testing Agency 1.6 Table of Contents 1.7 SI Units 1.8 Safety Caveat 1.9 Referenced Documents 2 ASTM Standards 2.1 SAE Documents 2.2 ASNT Documents 2.3 U.S. Government Documents 2.4 Definitions 3 Summary of Guide 4 Principle 4.1 Method 4.2 Magnetization 4.3 Types of Magnetic Particle and Their Use 4.4 Evaluation of Indications 4.5 Typical Magnetic Particle Indications 4.6 Significance and Use 5 Equipment 6 Types 6.1 1 This guide is under the jurisdiction of ASTM Committee E07 on Nondestruc- tive Testing and is the direct responsibility of Subcommittee E07.03 on Magnetic Particle and Penetrant Testing. Current edition approved July 10, 2001. Published September 2001. Originally published as E 709 – 80. Last previous edition E 709 – 95. 2 For ASME Boiler and Pressure Vessel Code Applications see related Guide SE-709 in Section II of that Code. 1 Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States. Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 3. SECTION Portability 6.2 Yokes 6.3 Prods 6.4 Black Light 6.5 Equipment Verification 6.6 Examination Area 7 Light Intensity for Examination 7.1 Housekeeping 7.2 Magnetic Particle Materials 8 Particle Types 8.2 Particle Characteristics 8.3 Dry Particles 8.4 Wet Particle Systems 8.5 Part Preparation 9 General 9.1 Cleaning Examination Surface 9.2 Sequence of Operations 10 Sequencing Particle Application and Establishing Mag- netic Flux Field 10.1 Types of Magnetizing Currents 11 Basic Current Types 11.1 Part Magnetization Techniques 12 Examination Coverage 12.1 Direct and Indirect Magnetization 12.2 Choosing a Magnetization Technique 12.3 Direction of Magnetic Fields 13 Discontinuity Orientation vs Magnetic Field Direction 13.1 Circular Magnetization 13.2 Torodial Magnetization 13.3 Longitudinal Magnetization 13.4 Multidirectional Magnetization 13.5 Magnetic Field Strength 14 Magnetizing Field Strengths 14.1 Establishing Field Strengths 14.2 Guidelines for Establishing Magnetic Fields 14.3 Application of Dry and Wet Magnetic Particles 15 Dry Magnetic Particles 15.1 Wet Particles Applications 15.2 Magnetic Slurry/Paint 15.3 Magnetic Polymers 15.4 Interpretation of Indications 16 Valid Indications 16.1 Recording of Indications 17 Means of Recording 17.1 Accompanying Information 17.2 Demagnetization 18 Applicability 18.1 Demagnetization Methods 18.2 Extent of Demagnetization 18.3 Post Examination Cleaning 19 Particle Removal 19.1 Means of Particle Removal 19.2 Evaluation of System Performance/Sensitivity 20 Contributor Factors 20.1 Maintenance and Calibration of Equipment 20.2 Equipment Checks 20.3 Examination Area Light Level Control 20.4 Dry Particle Quality Control Tests 20.5 Wet Particle Quality Control Tests 20.6 Bath Characteristics Control 20.7 Verifying System Performance 20.8 Procedure and Report 21 Written Procedure 21.1 Written Reports 21.2 Acceptance Standards 22 Safety 23 SECTION Precision and Bias 24 Keywords 25 Annex AnnexA1 Appendix X1. Appendix X1 Appendix X2. Appendix X2 1.8 The numerical values shown in inch-pound units are to be regarded as the standard. SI units are provided for informa- tion only. 1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro- priate safety and health practices and determine the applica- bility of regulatory limitations prior to use. 2. Referenced Documents 2.1 ASTM Standards: A 275/A 275M Test Method for Magnetic Particle Exami- nation of Steel Forgings3 A 456/A 456M Specification for Magnetic Particle Exami- nation of Large Crankshaft3 D 93 Test Methods for Flash Point by Pensky-Martens Closed Tester4 D 129 Test Method for Sulfur in Petroleum Products (Gen- eral Bomb Method)4 D 445 Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and the Calculation of Dynamic Viscosity)4 D 808 Test Method for Chlorine in New and Used Petro- leum Products (Bomb Method)4 D 1966 Test Method for Foots in Raw Linseed Oil Gravi- metric Method5 E 165 Test Method for Liquid Penetrant Examination6 E 543 Practice for Agencies Performing Nondestructive Testing6 E 1316 Terminology for Nondestructive Examinations6 E 1444 Practice for Magnetic Particle Examination6 2.2 Society of Automotive Engineers (SAE): Aerospace Materials Specifications:7 AMS 2300 Premium Aircraft Quality Steel Cleanliness Magnetic Particle Inspection Procedure AMS 2301 Aircraft Quality Steel Cleanliness Magnetic Par- ticle Inspection Procedure AMS 2303 Aircraft Quality Steel Cleanliness Martensitic Corrosion Resistant Steels Magnetic Particle Inspection Procedure AMS 2641 Vehicle Magnetic Particle Inspection AMS 3040 Magnetic Particles, Non-fluorescent, Dry Method AMS 3041 Magnetic Particles, Non-fluorescent, Wet Method, Oil Vehicle, Ready to Use 3 Annual Book of ASTM Standards, Vol 01.05. 4 Annual Book of ASTM Standards, Vol 05.01. 5 Annual Book of ASTM Standards, Vol 06.03. 6 Annual Book of ASTM Standards, Vol 03.03. 7 Available from Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096. E 709 2 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 4. AMS 3042 Magnetic Particles, Non-fluorescent, Wet Method, Dry Powder AMS 3043 Magnetic Particles, Non-fluorescent, Oil Ve- hicle, Aerosol Packaged AMS 3044 Magnetic Particles, Fluorescent, Wet Method, Dry Powder AMS 3045 Magnetic Particles, Non-fluorescent, Wet Method, Oil Vehicle, Ready to Use AMS 3046 Magnetic Particles, Non-fluorescent, Wet Method, Oil Vehicle, Aerosol Packaged AMS 5062 Steel, Low Carbon Bars, Forgings, Tubing, Sheet, Strip, and Plate 0.25 Carbon, Maximum AMS 5355 Investment Castings AMS-I-83387 Inspection Process, Magnetic Rubber AS 4792 Water Conditioning Agents for Aqueous Magnetic Particle Inspection AS 5282 Tool Steel Ring Standard for Magnetic Particle Inspection AS 5371 Reference Standards Notched Shims for Magnetic Particle Inspection 2.3 American Society for Nondestructive Testing:8 SNT-TC-1A Recommended Practice Magnetic Particle Method CP-189 ASNT Qualification and Certification of Nonde- structive Testing Personnel 2.4 Federal Standards:9 A-A-59230 Fluid, Magnetic Particle Inspection, Suspension FED-STD 313 Material Safety Data Sheets Preparation and the Submission of 2.5 OSHA Document:10 29CFR 1910.1200 Hazard Communication 2.6 AIA Documents: NAS 410 Nondestructive Testing Personnel Qualification and Certification 3. Terminology 3.1 For definitions of terms used in the practice, refer to Terminology E 1316 4. Summary of Guide 4.1 Principle—The magnetic particle method is based on the principle that magnetic field lines when present in a ferromagnetic material, will be distorted by a change in material continuity, such as a sharp dimensional change or a discontinuity. If the discontinuity is open to or close to the surface of a magnetized material, flux lines will be distorted at the surface, a condition termed as “flux leakage.” When fine magnetic particles are distributed over the area of the discon- tinuity while the flux leakage exists, they will be held in place and the accumulation of particles will be visible under the proper lighting conditions. While there are variations in the magnetic particle method, they all are dependent on this principle, that magnetic particles will be retained at the locations of magnetic flux leakage. 4.2 Method—While this practice permits and describes many variables in equipment, materials, and procedures, there are three steps essential to the method: 4.2.1 The part must be magnetized. 4.2.2 Magnetic particles of the type designated in the contract/purchase order/specification must be applied while the part is magnetized. 4.2.3 Any accumulation of magnetic particles must be observed, interpreted, and evaluated. 4.3 Magnetization: 4.3.1 Ways to Magnetize—A ferromagnetic material can be magnetized either by passing an electric current through the material or by placing the material within a magnetic field originated by an external source. The entire mass or a portion of the mass can be magnetized as dictated by size and equipment capacity or need. As previously noted, the discon- tinuity must interrupt the normal path of the magnetic field lines. If a discontinuity is open to the surface, the flux leakage will be at the maximum for that particular discontinuity. When that same discontinuity is below the surface, flux leakage evident on the surface will be less. Practically, discontinuities must be open to the surface, to create sufficient flux leakage to accumulate magnetic particles. 4.3.2 Field Direction—If a discontinuity is oriented parallel to the magnetic field lines, it may be essentially undetectable. Therefore, since discontinuities may occur in any orientation, it may be necessary to magnetize the part or area of interest twice or more sequentially in different directions by the same method or a combination of methods (see Section 13) to induce magnetic field lines in a suitable direction in order to perform an adequate examination. 4.3.3 Field Strength—The magnetic field must be of suffi- cient strength to indicate those discontinuities which are unacceptable, yet must not be so strong that an excess of particles is accumulated locally thereby masking relevant indications (see Section 14). 4.4 Types of Magnetic Particles and Their Use—There are various types of magnetic particles available for use in mag- netic particle examination. They are available as dry powders (fluorescent and nonfluorescent) ready for use as supplied (see 8.4), powder concentrates (fluorescent and nonfluorescent) for dispersion in water or suspending light petroleum distillates (see 8.5), magnetic slurries/paints (see 8.5.7), and magnetic polymer dispersions (see 8.5.8). 4.5 Evaluation of Indications—When the material to be examined has been properly magnetized, the magnetic particles have been properly applied, and the excess particles properly removed, there will be accumulations of magnetic particles at the points of flux leakage. These accumulations show the distortion of the magnetic field and are called indications. Without disturbing the particles, the indications must be examined, classified, interpreted as to cause, compared with the acceptance standards, and a decision made concerning the disposition of the material that contains the indication. 4.6 Typical Magnetic Particle Indications: 4.6.1 Surface Discontinuities—Surface discontinuities, with 8 Available from American Society for Nondestructive Testing, 1711 Arlingate Plaza, P.O. Box 28518, Columbus, OH 43228-0518. 9 Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700 Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS. 10 Available from Occupational Safety and Health Review Commission, 1825 K Street, N.W., Washington, DC 20006. E 709 3 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 5. few exceptions, produce sharp, distinct patterns (see Annex A1). 4.6.2 Near-surface discontinuities—Near-surface disconti- nuities produce less distinct indications than those open to the surface. The patterns are broad, rather than sharp, and the particles are less tightly held (see Annex A1). 5. Significance and Use 5.1 The magnetic particle method of nondestructive exami- nation indicates the presence of surface and near-surface discontinuities in materials that can be magnetized (ferromag- netic). This method can be used for production examination of parts/components or structures and for field applications where portability of equipment and accessibility to the area to be examined are factors. The ability of the method to find small discontinuities can be enhanced by using fluorescent particles suspended in a suitable vehicle and by introducing a magnetic field of the proper strength whose orientation is as close as possible to 90° to the direction of the suspected discontinuity (see 4.3.2). Making the surface smoother improves mobility of the magnetic particles under the influence of the magnetic field to collect on the surface where magnetic flux leakage occurs. 6. Equipment 6.1 Types—There are a number of types of equipment available for magnetizing ferromagnetic parts and components. With the exception of a permanent magnet, all equipment requires a power source capable of delivering the required current levels to produce the magnetic field. The current used dictates the sizes of cables and the capability of relays, switching contacts, meters and rectifier if the power source is alternating current. 6.2 Portability—Portability, which includes the ability to hand carry the equipment, can be obtained from yokes. Their size limits their ability to provide the magnetic fields that can be obtained from equipment with larger current flows. General purpose mobile equipment which may be truck mounted, is usually designed either for use with prods on the ends of two cables or with only the cables which are attached to the piece being examined, threaded through an opening in it or wrapped around it. Mobility is limited by the cable and size and the environment. Underwater examination on oil drilling platforms and oil production platforms offshore are examples of a hostile environment. 6.3 Yokes—Yokes are usually C-shaped electromagnets which induce a magnetic field between the poles (legs) and are used for local magnetization (Fig. 1). Many portable yokes have articulated legs (poles) that allow the legs to be adjusted to contact irregular surfaces or two surfaces that join at an angle. 6.3.1 Permanent Magnets—Permanent magnets are avail- able but their use may be restricted for many applications. Permanent magnets can lose their magnetic field generating capacity by being partially demagnetized by a stronger flux field, being damaged, or dropped. In addition, the particle mobility, created by AC and half-wave rectified current pulsa- tions in electromagnetic yokes, is not present. Particles, steel filings, chips, and scale clinging to the poles can create a housekeeping problem. 6.4 Prods—Prods are used for local magnetizations, see Fig. 2. The prod tips that contact the piece should be aluminum, copper braid, or copper pads rather than solid copper. With solid copper tips, accidental arcing during prod placement or removal can cause copper penetration into the surface which may result in metallurgical damage (softening, hardening, cracking, etc.). See 12.3.1.1(a). Open-circuit voltages should not exceed 25 V. 6.4.1 Remote Control Switch—A remote-control switch, which may be built into the prod handles, should be provided to permit the current to be turned on after the prods have been properly placed and to turn it off before the prods are removed in order to minimize arcing (arc burns). (See 12.3.1.1(a).) 6.5 Black Light—The black light must be capable of devel- oping the required wavelengths of 330 to 390 nm with an intensity at the examination surface that satisfies 7.1.2. Wave- lengths at or near 365 nm shall predominate. Suitable filters should remove the extraneous visible light emitted by black lights (violet or blue 405 and 435-nm Hg lines and greenish- yellow 577-nm Hg line). Some high-intensity black light bulbs may emit unacceptable amounts of greenish-yellow light which may cause fluorescent indications to become invisible. A drop, greater than 10 %, in line voltage greater than 610 % can cause a change in black light output with consequent incon- sistent performance. A constant voltage transformer should be (a) (b) FIG. 1 Yoke Method of Part Magnetization E 709 4 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 6. used where there is evidence of voltage changes greater than 10 %. 6.6 Equipment Verification—See Section 20. 7. Examination Area 7.1 Light Intensity for Examination—Magnetic indications found using nonfluorescent particles are examined under vis- ible light. Indications found using fluorescent particles must be examined under black (ultraviolet) light. This requires a darkened area with accompanying control of the visible light intensity. 7.1.1 Visible Light Intensity—The intensity of the visible light at the surface of the part/work piece undergoing exami- nation should be a minimum of 100 foot candles (1000 lux). The intensity of ambient visible light in the darkened area where fluorescent magnetic particles examination is performed should not exceed 2 foot candles (20 lux). 7.1.1.1 Field Inspections—For some field inspections using nonfluorescent particles, visible light intensities as low as 50 foot candles (500 lux) may be used when agreed on by the contracting agency. 7.1.2 Black (Ultraviolet) Light: 7.1.2.1 Black Light Intensity—The black light intensity at the examination surface shall be not less than 1000 µW/cm2 when measured with a suitable black light meter. 7.1.2.2 Black Light Warm-up—Allow the black light to warm up for a minimum of 5 min prior to its use or measurement of the intensity of the ultraviolet light emitted. 7.1.3 Dark Area Eye Adaptation—The generally accepted practice is that an inspector be in the darkened area at least one (1) minute so that his/her eyes will adapt to dark viewing prior to examining parts under UV illumination.11 Caution— Photochromic or permanently tinted lenses should not be worn during examination. 7.2 Housekeeping—The examination area should be kept free of interfering debris. If fluorescent materials are involved, the area should also be kept free of fluorescent objects not related to the part/piece being examined. 8. Magnetic Particle Materials 8.1 Magnetic Particle Properties: 8.1.1 Dry Particle Properties—AMS 3040 describes the generally accepted properties of dry method particles. 8.1.2 Wet Particle Properties—The following documents describe the generally accepted properties of wet method particles in their various forms: AMS 3041 AMS 3042 AMS 3043 AMS 3044 AMS 3045 AMS 3046 8.1.3 Suspension Vehicle— The suspension vehicle for wet- method examination may be either a light oil distillate fluid (refer to AMS 2641 or A-A-52930) or a conditioned water vehicle (refer to AS 4792). 11 Drury, Colin G., and Watson, Jean, “Human Factors Good Practices in Fluorescent Penetrant Inspection”, http://hfskyway.faa.gov, then “documents”, then “Research Reports 98–99”, then “search” for “fpi”, then “go”. (a) Prod Magnetization (b) Copper-Braided Tip Prods (c) Single-Prod Contacts Magnetization (d) Double-Prod Contacts FIG. 2 Localized Area Magnetization Using Prod Technique E 709 5 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 7. 8.2 Particle Types—The particles used in either dry or wet magnetic particle examination techniques are basically finely divided ferromagnetic materials which have been treated to impart color (fluorescent and nonfluorescent) in order to make them highly visible (contrasting) against the background of the surface being examined. The particles are designed for use either as a free flowing dry powder or for suspension at a given concentration in a suitable liquid medium. 8.3 Particle Characteristics—The magnetic particles must have high permeability to allow ease of magnetizing and attraction to the discontinuity and low retentivity so they will not be attracted (magnetic agglomeration) to each other. Control of particle size and shape is required to obtain consistent results. The particles should be nontoxic, free from rust, grease, paint, dirt, and other deleterious materials that might interfere with their use; see 20.5 and 20.6. Both dry and wet particles are considered safe when used in accordance with the manufacturer’s instructions. They generally afford a very low hazard potential with regard to flammability and toxicity. 8.4 Dry Particles—Dry magnetic powders are designed to be used as supplied and are applied by spraying or dusting directly onto the surface of the part being examined. They are generally used on an expendable basis although the particles may be collected and reused. However, to maintain particle size and control possible contamination, this is not a normal practice. Dry powders may also be used under extreme environmental conditions. They are not affected by cold; therefore examination can be carried out at temperatures that would thicken or freeze wet baths. They are also heat resistant; some powders may be usable at temperatures up to 600°F (315°C). Some colored, organic coatings applied to dry par- ticles to improve contrast lose their color at temperatures this high, making the contrast less effective. Fluorescent dry particles cannot be used at this high a temperature; the manufacturer should be contacted for the temperature limita- tion or tests should be run. 8.4.1 Advantages—The dry magnetic particle technique is generally superior to the wet technique for detection of near-surface discontinuities: (a) for large objects when using portable equipment for local magnetization; (b) superior par- ticle mobility is obtained for relatively deep-seated flaws half-wave rectified current as the magnetizing source; (c) ease of removal. 8.4.2 Disadvantages—The dry magnetic particle technique; (a) cannot be used in confined areas without proper safety breathing apparatus; (b) can be difficult to use in overhead magnetizing positions; (c) does not always leave evidence of complete coverage of part surface as with the wet technique; (d) is likely to have lower production rates than the wet technique; and (e) is difficult to adapt to any type of automatic system. 8.4.3 Nonfluorescent Colors—Although dry magnetic par- ticle powder can be almost any color, the most frequently employed colors are light gray, black, red, or yellow. The choice is generally based on maximum contrast with the surface to be examined. The examination is done under visible light. 8.4.4 Fluorescent—Fluorescent dry magnetic particles are also available, but are not in general use primarily because of their higher cost and use limitations. They require a black light source and a darkened work area. These requirements are not often available in the field-type locations where dry magnetic particle examinations are especially suitable. 8.4.5 Dual Colors—Dual-colored particles are available that are readily detectable in visible light and also display fluorescence when viewed under ultra-violet light or a combi- nation visible and ultra-violet light. Use in accordance with the manufacturer’s recommendations. 8.5 Wet Particle Systems—Wet magnetic particles are de- signed to be suspended in a vehicle such as water or light petroleum distillate at a given concentration for application to the test surface by flowing, spraying, or pouring. They are available in both fluorescent and nonfluorescent concentrates. In some cases the particles are premixed with the suspending vehicle by the supplier, but usually the particles are supplied as a dry concentrate or paste concentrate which is mixed with the distillate or water by the user. The suspensions are normally used in wet horizontal magnetic particle equipment in which the suspension is retained in a reservoir and recirculated for continuous use. The suspension may also be used on an expendable basis dispensed from an aerosol. 8.5.1 Primary Use—Because the particles used are smaller, wet method techniques are generally used to locate smaller discontinuities than the dry method is used for. The liquid vehicles used will not perform satisfactorily when their viscos- ity exceeds 5cSt (5 mm2 /s) at the operating temperature. If the suspension vehicle is a hydrocarbon, its flash point limits the top temperature. Mixing equipment is usually required to keep wet method particles uniformly in suspension. 8.5.2 Where Used—The wet fluorescent method usually is performed indoors or in areas where shelter and ambient light level can be controlled and where proper application equip- ment is available. 8.5.3 Color—The color chosen for any given examination should be one that best contrasts with the examination surface. Because contrast is invariably higher with fluorescent materi- als, these are utilized in most wet process examinations. Fluorescent wet method particles normally glow a bright yellow-green when viewed under black light, although other colors are available. Non-fluorescent particles are usually black or reddish brown, although other colors are available. Dual- colored particles are available that are readily detectable in visible light and also display fluorescence when viewed under ultra-violet light or a combination visible and ultra-violet light. Refer to 8.5.5. 8.5.4 Suspension Vehicles—Generally the particles are sus- pended in a light petroleum (low-viscosity) distillate or condi- tioned water. (If sulfur or chlorine limits are specified, use Test Methods D 129 and D 808 to determine their values. 8.5.4.1 Petroleum Distillates—Low-viscosity light petro- leum distillates vehicles (AMS 2641 Type 1 or equal) are ideal for suspending both fluorescent and nonfluorescent magnetic particles and are commonly employed. (1) Advantages—Two significant advantages for the use of petroleum distillate vehicles are: (a) the magnetic particles are E 709 6 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 8. suspended and dispersed in petroleum distillate vehicles with- out the use of conditioning agents; and (b) the petroleum distillate vehicles provide a measure of corrosion protection to parts and the equipment used. (2) Disadvantages—Principal disadvantages are flamma- bility and availability. It is essential, therefore, to select and maintain readily available sources of supply of petroleum distillate vehicles that have as high a flash point as practicable to avoid possible flammability problems. (3) Characteristics—Petroleum distillate vehicles to be used in wet magnetic particle examination should possess the following: (a) viscosity should not exceed 3.0 cSt (3 mm2 /s) at 100°F (38°C) and not more than 5.0 cSt (5 mm2 /s) at the lowest temperature at which the vehicle will be used; when tested in accordance with Test Method D 445, in order not to impede particle mobility (see 20.7.3), (b) minimum flash point, when tested in accordance with Test Methods D 93, should be 200°F (93°C) in order to minimize fire hazards (see 20.7.4), (c) odorless; not objectionable to user, (d) low inherent fluores- cence if used with fluorescent particles; that is, it should not interfere significantly with the fluorescent particle indications (see 20.6.4.1), and (e) nonreactive; should not degrade sus- pended particles. 8.5.4.2 Water Vehicles with Conditioning Agents—Water may be used as a suspension vehicle for wet magnetic particles provided suitable conditioning agents are added which provide proper wet dispersing, in addition to corrosion protection for the parts being tested and the equipment in use. Plain water does not disperse some types of magnetic particles, does not wet all surfaces, and is corrosive to parts and equipment. On the other hand, water suspensions of magnetic particles are safer to use since they are nonflammable. The selection and concentration of the conditioning agent should be as recom- mended by the particle manufacturer. The following are recommended properties for water vehicles containing condi- tioning agents for use with wet magnetic particle examination: (1) Wetting Characteristics—The vehicle should have good wetting characteristics; that is, wet the surface to be tested, give even, complete coverage without evidence of dewetting the test surface. Smooth test surfaces require that a greater percentage of wetting agent be added than is required for rough surface. Nonionic wetting agents are recommended (see 20.7.5). (2) Suspension Characteristics—Impart good dispersabil- ity; that is, thoroughly disperse the magnetic particles without evidence of particle agglomeration. (3) Foaming—Minimize foaming; that is, it should not produce excessive foam which would interfere with indication formation or cause particles to form scum with the foam. (4) Corrosiveness—It should not corrode parts to be tested or the equipment in which it is used. (5) Viscosity Limit—The viscosity of the conditioned water should not exceed a maximum viscosity of 3 cSt (3 mm2 /s) at 100°F (38°C) (see 20.7.3). (6) Fluorescence—The conditioned water should not fluo- resce if intended for use with fluorescent particles. (7) Nonreactiveness—The conditioned water should not cause deterioration of the suspended magnetic particles. (8) Water pH—The pH of the conditioned water should not be less than 7.0 or exceed 10.5. (9) Odor—The conditioned water should be essentially odorless. 8.5.5 Concentration of Wet Magnetic Particle Suspension— The initial bath concentration of suspended magnetic particles should be as specified or as recommended by the manufacturer and should be checked by settling volume measurements and maintained at the specified concentration on a daily basis. If the concentration is not maintained properly, examination results can vary greatly. The concentration of dual-colored particles in the wet-method bath suspension may be adjusted to best perform in the desired lighting environment. Higher particle concentration is recommended for visible light areas and lower particle concentration is recommended for ultraviolet light areas. Use in accordance with the particle manufacturer’s recommendations. 8.5.6 Application of Wet Magnetic Particles (see 15.2). 8.5.7 Magnetic Slurry/Paint Systems—Another type of ex- amination vehicle is the magnetic slurry/paint type consisting of a heavy oil in which flake-like particles are suspended. The material is normally applied by brush before the part is magnetized. Because of the high viscosity, the material does not rapidly run off surfaces, facilitating the inspection of vertical or overhead surfaces. The vehicles may be combus- tible, but the fire hazard is very low. Other hazards are very similar to those of the oil and water vehicles previously described. 8.5.8 Polymer-Based Systems—The vehicle used in the magnetic polymer is basically a liquid polymer which disperses the magnetic particles and which cures to an elastic solid in a given period of time, forming fixed indications. Viscosity limits of standard wet technique vehicles do not apply. Care should be exercised in handling these polymer materials. Use in accordance with manufacturer’s instructions and precau- tions. This technique is particularly applicable to examine areas of limited visual accessibility, such as bolt holes. 9. Part Preparation 9.1 General—The surface of the part to be examined should be essentially clean, dry, and free of contaminants such as dirt, oil, grease, loose rust, loose mill sand, loose mill scale, lint, thick paint, welding flux/slag, and weld splatter that might restrict particle movement. See 15.1.2 about applying dry particles to a damp/wet surface. When testing a local area, such as a weld, the areas adjacent to the surface to be examined, as agreed by the contracting parties, must also be cleaned to the extent necessary to permit detection of indications. 9.1.1 Nonconductive Coatings—Thin nonconductive coat- ings, such as paint in the order of 0.02 to 0.05 mm (1 or 2 mil) will not normally interfere with the formation of indications, but they must be removed at all points where electrical contact is to be made for direct magnetization. Indirect magnetization does not require electrical contact with the part/piece. See Section 12.2. If a nonconducting coating/plating is left on the area to be examined that has a thickness greater than 0.05 mm (2 mil), it must be demonstrated that discontinuities can be detected through the maximum thickness applied. 9.1.2 Conductive Coatings—A conductive coating (such as E 709 7 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 9. chrome plating and heavy mill scale on wrought products resulting from hot forming operations) can mask discontinui- ties. As with nonconductive coatings, it must be demonstrated that the discontinuities can be detected through the coating. 9.1.3 Residual Magnetic Fields—If the part/piece holds a residual magnetic field from a previous magnetization that will interfere with the examination, the part must be demagnetized. See Section 18. 9.2 Cleaning Examination Surface—Cleaning of the test surface may be accomplished by detergents, organic solvents, or mechanical means. As-welded, as-rolled, as-cast, or as- forged surfaces are generally satisfactory, but if the surface is unusually nonuniform, as with burned-in sand or a very rough weld deposit, interpretation may be difficult because of me- chanical entrapment of the magnetic particles. In case of doubt, any questionable area should be recleaned and reexamined (see 9.1). An extensive presentation of applicable cleaning methods is described in Annex A1 of Test Method E 165. 9.2.1 Plugging and Masking Small Holes and Openings— Unless prohibited by the purchaser, small openings and oil holes leading to obscure passages or cavities can be plugged or masked with a suitable nonabrasive material which is readily removed. In the case of engine parts, the material must be soluble in oil. Effective masking must be used to protect components that may be damaged by contact with the particles or particle suspension. 10. Sequence of Operations 10.1 Sequencing Particle Application and Establishing Magnetic Flux Field—The sequence of operation in magnetic particle examination applies to the relationship between the timing and application of particles and establishing the mag- netizing flux field. Two basic techniques apply, that is, con- tinuous (see 10.1.1 and 10.1.2) and residual (see 10.1.3), both of which are commonly employed in industry. 10.1.1 Continuous Magnetization—Continuous magnetiza- tion is employed for most applications utilizing either dry or wet particles and should be used unless specifically prohibited in the contract, purchase order, or specification. The sequence of operation for the dry and the wet continuous magnetization techniques are significantly different and are discussed sepa- rately in 10.1.1.1 and 10.1.1.2. 10.1.1.1 Dry Continuous Magnetization Technique—Unlike a wet suspension, dry particles lose most of their mobility when they contact the surface of a part. Therefore, it is imperative that the part/area of interest be under the influence of the applied magnetic field while the particles are still airborne and free to be attracted to leakage fields. This dictates that the flow of magnetizing current be initiated prior to the application of dry magnetic particles and terminated after the application of powder has been completed and any excess has been blown off. Magnetizing currents of the half-wave rectified alternating and unrectified AC provide additional particle mobility on the surface of the part. Examination with dry particles is usually carried out in conjunction with prod-type localized magnetizations, and buildup of indications is ob- served as the particles are being applied. 10.1.1.2 Wet Continuous Magnetization Technique—The wet continuous magnetization technique generally applies to those parts processed on a horizontal wet type unit. In practice, it involves bathing the part with the examination medium to provide an abundant source of suspended particles on the surface of the part and terminating the bath application immediately prior to cutting off of the magnetizing current. The duration of the magnetizing current is typically on the order of 1⁄2 s with two or more shots given to the part. 10.1.1.3 Polymer or Slurry Continuous Magnetization Technique—Prolonged or repeated periods of magnetization are often necessary for polymer- or slurry-base suspensions because of slower inherent magnetic particle mobility in the high-viscosity suspension vehicles. 10.1.2 True Continuous Magnetization Technique—In this technique, the magnetizing current is sustained throughout both the processing and examination of the part. 10.1.3 Residual Magnetization Techniques: 10.1.3.1 Residual Magnetization—In this technique, the examination medium is applied after the magnetizing force has been discontinued. It can be used only if the material being tested has relatively high retentivity so the residual leakage field will be of sufficient strength to attract and hold the particles and produce indications. This technique may be advantageous for integration with production or handling requirements or for intentionally limiting the sensitivity of the examination. It has found wide use examining pipe and tubular goods. Unless demonstrations with typical parts indicate that the residual field has sufficient strength to produce relevant indications of discontinuities (see 20.8) when the field is in proper orientation, the continuous method should be used. 10.1.3.2 Current Quick Break—Equipment, full-wave rec- tified AC, for residual magnetization must be designed to provide a consistent quick break of the magnetizing current. 11. Types of Magnetizing Currents 11.1 Basic Current Types—The four basic types of current used in magnetic particle examination to establish part mag- netization are alternating current, single phase half-wave rec- tified alternating current, full-wave rectified alternating current, and for a special application, DC. 11.1.1 Alternating Current (AC)—Part magnetization with alternating current is preferred for those applications where examination requirements call for the detection of discontinui- ties, such as fatigue cracks, that are open to the surface. Associated with AC is a “skin effect” that confines the magnetic field at or near to the surface of a part. In contrast, both half-wave rectified alternating current and full-wave rectified alternating current produce a magnetic field having maximum penetrating capabilities which should be used when near-surface discontinuities are of concern. Alternating current is also extensively used for the demagnetization of parts after examination. The through-coil technique is normally used for this purpose due to its simple, fast nature. See Fig. 3. 11.1.2 Half-Wave Rectified Alternating Current—Half-wave rectified alternating current is frequently used in conjunction with dry particles and localized magnetization (for example, prods or yokes) to achieve some depth of penetration for detection of typical discontinuities found in weldments and ferrous castings. As with AC for magnetization, single-phase E 709 8 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 10. current is utilized and average value measured as “magnetizing current.” 11.1.3 Full-Wave Rectified Alternating Current—Full-wave rectified alternating current may utilize single- or three-phase current. Three-phase current has the advantage of lower line amperage whereas single-phase equipment is less expensive. Full-wave rectified AC is commonly used when the residual method is to be employed. With the continuous method, full-wave rectified AC is used for magnetization of coated and plated parts. Because particle movement, either dry or wet is noticeably slower, precautions must be taken to ensure that sufficient time is allowed for formation of indications. 11.1.4 Direct Current (DC)—A bank of batteries or a D C generator produce a direct magnetizing current. They have largely given way to half-wave rectified or full-wave rectified AC except for a few specialized applications, primarily be- cause of battery cost and maintenance. One such example is the charging of a bank of capacitors, which on discharge is used to establish a residual magnetic field in tubing, casing, line pipe, and drill pipe. 12. Part Magnetization Techniques 12.1 Examination Coverage—All examinations should be conducted with sufficient area overlap to assure the required coverage at the specified sensitivity has been obtained. 12.2 Direct and Indirect Magnetization—A part can be magnetized either directly or indirectly. For direct magnetiza- tion the magnetizing current is passed directly through the part creating a circular magnetic field in the part. With indirect magnetization techniques a magnetic field is induced in the part which can create a circular/toroidal, longitudinal, or multidi- rectional magnetic field in the part. The techniques described in 20.8 for verifying that the magnetic fields have the anticipated direction and strength should be employed. This is especially important when using the multidirection technique to examine complex shapes. 12.3 Choosing Magnetization Technique—The choice of direct or indirect magnetization will depend on such factors as size, configuration, or ease of processing. Table 1 compares the advantages and limitations of the various methods of part magnetization. TABLE 1 Advantages and Limitations of the Various Ways of Magnetizing a Part Magnetizing Technique and Material Form Advantages Limitations I. Direct Contact Part Magnetization (see 12.3.1) Head/Tailstock Contact Solid, relatively small parts (castings, forgings, machined pieces) that can be processed on a horizontal wet unit 1. Fast, easy technique. 1. Possibility of arc burns if poor contact conditions exist. 2. Circular magnetic field surrounds current path. 2. Long parts should be magnetized in sections to facilitate bath application without resorting to an overly long current shot. 3. Good sensitivity to surface and near-surface discontinuities. 4. Simple as well as relatively complex parts can usually be easily processed with one or more shots. 5. Complete magnetic path is conducive to maximizing residual characteristics of material. Large castings and forgings 1. Large surface areas can be processed and examined in relatively short time. 1. High amperage requirements (16 000 to 20 000 A) dictate special DC power supply. Cylindrical parts such as tubing, pipe, hollow shafts, etc. 1. Entire length can be circularly magnetized by contacting, end to end. 1. Effective field limited to outside surface and cannot be used for inside diameter examination. 2. Ends must be conductive to electrical contacts and capable of carrying required current without excessive heat. Cannot be used on oil country tubular goods because of possibility of arc burns. Long solid parts such as billets, bars, shafts, etc. 1. Entire length can be circularly magnetized by contacting, end to end. 1. Voltage requirements increase as length increases due to greater impedance of cable and part. 2. Current requirements are independent of length. 2. Ends must be conductive to electrical contact and capable of carrying required current without excessive heat. 3. No end loss. Prods: Welds 1. Circular field can be selectively directed to weld area by prod placement. 1. Only small area can be examined at one time. FIG. 3 Coil Magnetization E 709 9 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 11. TABLE 1 Continued Magnetizing Technique and Material Form Advantages Limitations 2. In conjunction with half-wave rectified alternating current and dry powder, provides excellent sensitivity to subsurface discontinuities as well as surface type. 2. Arc burns due to poor contact. 3. Flexible, in that prods, cables, and power packs can be brought to examination site. 3. Surface must be dry when dry powder is being used. 4. Prod spacing must be in accordance with the magnetizing current level. Large castings or forgings 1. Entire surface area can be examined in small increments using nominal current values. 1. Coverage of large surface area require a multiplicity of shots that can be very time-consuming. 2. Circular field can be concentrated in specific areas that historically are prone to discontinuities. 2. Possibility of arc burns due to poor contact. Surface should be dry when dry powder is being used. 3. Equipment can be brought to the location of parts that are difficult to move. 4. In conjunction with half-wave rectified alternating current and dry powder, provides excellent sensitivity to near surface subsurface type discontinuities that are difficult to locate by other methods. II. Indirect Part Magnetization (see 12.3.2) Central Conductor Miscellaneous parts having holes through which a conductor can be placed such as: Bearing race Hollow cylinder Gear Large nut 1. No electrical contact to part and possibility of arc burns eliminated. 1. Size of conductor must be ample to carry required current. 2. Circumferentially directed magnetic field is generated in all surfaces, surrounding the conductor (inside diameter, faces, etc.). 2. Ideally, conductor should be centrally located within hole. 3. Ideal for those cases where the residual method is applicable. 3. Larger diameters require repeated magnetization with conductor against inside diameter and rotation of part between processes. Where continuous magnetization technique is being employed, examination is required after each magnetization. 4. Light weight parts can be supported by the central conductor. 5. Multiple turns may be used to reduce current required. Large clevis Pipe coupling, casing/tubing Tubular type parts such as: Pipe/Casting Tubing Hollow shaft 1. No electrical contact of part required. 1. Outside surface sensitivity may be somewhat less than that obtained on the inside surface for large diameter and extremely heavy wall. 2. Inside diameter as well as outside diameter examination. 3. Entire length of part circularly magnetized. Large valve bodies and similar parts 1. Provides good sensitivity for detection of discontinuities located on internal surfaces. 1. Outside surface sensitivity may be somewhat less than that obtained on the inside diameter for heavy wall. Coil/Cable Wrap Miscellaneous medium-sized parts where the length predominates such as a crankshaft 1. All generally longitudinal surfaces are longitudinally magnetized to effectively locate transverse discontinuities. 1. Length may dictate multiple shot as coil is repositioned. Large castings, forgings, or shafting 1. Longitudinal field easily attained by means of cable wrapping. 1. Multiple magnetization may be required due to configuration of part. Miscellaneous small parts 1. Easy and fast, especially where residual magnetization is applicable. 1. L/D (length/diameter) ratio important consideration in determining adequacy of ampere-turns. 2. No electrical contact. 2. Effective L/D ratio can be altered by utilizing pieces of similar cross-sectional area. 3. Relatively complex parts can usually be processed with same ease as those with simple cross section. 3. Use smaller coil for more intense field. 4. Sensitivity diminishes at ends of part due to general leakage field pattern. 5. Quick break desirable to minimize end effect on short parts with low L/D ratio. Induced Current Fixtures Examination of ring-shaped part for circumfer- ential-type discontinuities. 1. No electrical contact. 1. Laminated core required through ring. 2. All surface of part subjected to toroidal-type mag- netic field. 2. Type of magnetizing current must be compatible with method. 3. Single process for 100 % coverage. 3. Other conductors encircling field must be avoided. 4. Can be automated. 4. Large diameters require special consideration. Ball examination 1. No electrical contact. 1. For small-diameter balls, limited to residual magnetization. 2. 100 % coverage for discontinuities in any direction with three-step process and proper orientation between steps. 3. Can be automated. E 709 10 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 12. TABLE 1 Continued Magnetizing Technique and Material Form Advantages Limitations Disks and gears 1. No electrical contact. 1. 100 % coverage may require two-step process with core or pole-piece variation, or both. 2. Good sensitivity at or near periphery or rim. 2. Type of magnetizing current must be compatible with part geometry. 3. Sensitivity in various areas can be varied by core or pole- piece selection. Yokes: Examination of large surface areas for surface-type discontinuities. 1. No electrical contact. 1. Time consuming. 2. Highly portable. 2. Must be systematically repositioned in view of random discontinuity orientation. 3. Can locate discontinuities in any direction with proper orientation. Miscellaneous parts requiring examination of localized areas. 1. No electrical contact. 1. Must be properly positioned relative to orientation of discontinuities. 2. Good sensitivity to direct surface discontinuities. 2. Relatively good contact must be established be- tween part and poles. 3. Highly portable. 3. Complex part geometry may cause difficulty. 4. Wet or dry technique. 4. Poor sensitivity to subsurface-type discontinuities except in isolated areas. 5. Alternating-current type can also serve as demagnetizer in some instances. 12.3.1 Direct Contact Magnetization—For direct magneti- zation, physical contact must be made between the ferromag- netic part and the current carrying electrodes connected to the power source. Both localized area magnetization and overall part magnetization are direct contact means of part magneti- zation achieved through the use of prods, head and tailstock, clamps, and magnetic leeches. 12.3.2 Localized Area Magnetization: 12.3.2.1 Prod Technique—The prod electrodes are first pressed firmly against the test part (Fig. 2(a)). The magnetizing current is then passed through the prods and into the area of the part in contact with the prods. This establishes a circular magnetic field in the part around and between each prod electrode, sufficient to carry out a local magnetic particle examination (Fig. 2(c) and Fig. 2(d)). Caution: Extreme care should be taken to maintain clean prod tips, to minimize heating at the point of contact and to prevent arc burns and local overheating on the surface being examined since these may cause adverse effects on material properties. Arc burns cause metallurgical damage; if the tips are solid copper, copper penetration into the part may occur. Prods should not be used on machined surfaces or on aerospace component parts. (1) Unrectified AC limits the prod technique to the detec- tion of surface discontinuities. Half-wave rectified AC is most desirable since it will detect both surface and near-surface discontinuities. The prod technique generally utilizes dry magnetic particle materials due to better particle mobility. Wet magnetic particles are not generally used with the prod technique because of potential electrical and flammability hazards. (2) Proper prod examination requires a second placement with the prods rotated approximately 90° from the first placement to assure that all existing discontinuities are re- vealed. Depending on the surface coverage requirements, overlap between successive prod placements may be necessary. On large surfaces, it is good practice to layout a grid for prod/yoke placement. 12.3.2.2 Manual Clamp/Magnetic Leech Technique—Local areas of complex components may be magnetized by electrical contacts manually clamped or attached with magnetic leeches to the part (Fig. 4). As with prods, sufficient overlap may be necessary if testing of the contact location is required. 12.3.2.3 Overall Magnetization: (1) Head and Tailstock Contact—Parts may be clamped between two electrodes (such as a head and tailstock of horizontal wet magnetic particle equipment) and the magne- tizing current applied directly through the part (Fig. 5). The size and shape of the part will determine whether both field directions can be obtained with such equipment. (2) Clamps—The magnetizing current may be applied to the FIG. 4 Direct-Contact Magnetization Through Magnetic Leech Clamp of Part E 709 11 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 13. test part by clamping the current carrying electrodes to the part, producing a circular magnetic field (Fig. 6). (3) Multidirectional Magnetization Technique—With suit- able circuitry, it is possible to produce a multidirectional (oscillating) field in a part by selectively switching the mag- netic field within the part between electrode contacts/clamps positioned approximately 90° apart. This permits building up indications in all possible directions and may be considered the equivalent of magnetizing in two or more directions (Fig. 7). On some complex shapes as many as 16 to 20 steps may be required with conventional equipment. With multidirectional magnetization, it is usually possible to reduce the magnetizing steps required by more than half. It is essential that the wet continuous method, be used and that the magnetic field direction and relative intensity be determined by one or more of the techniques described in 20.8. 12.3.3 Indirect Magnetization—Indirect part magnetization involves the use of a preformed coil, cable wrap, yoke, or a central conductor to induce a magnetic field. Coil, cable wrap, and yoke magnetization are referred to as longitudinal magne- tization in the part (see 13.3). 12.3.3.1 Coil and Cable Magnetization—When coil (Fig. 3) or cable wrap (Fig. 8) techniques are used, the magnetic field strength is proportional to ampere turns and depends on simple geometry (see 14.3.2). 12.3.3.2 Central Conductor, Induced Current Magnetization—Indirect circular magnetization of hollow pieces/parts can be performed by passing the magnetizing current through a central conductor (Fig. 9(a) and Fig. 9(b)) or cable used as a central conductor or through an induced current fixture (Fig. 9(c)). 12.3.3.3 Yoke Magnetization—A magnetic field can be in- duced into a part by means of an electromagnet (see Fig. 1), where the part or a portion thereof becomes the magnetic path between the poles (acts as a keeper) and discontinuities preferentially transverse to the alignment of the pole pieces are indicated. Most yokes are energized by AC, half-wave rectified FIG. 5 Direct Contact Magnetization Through Head/Tailstock FIG. 6 Direct Contact Overall Magnetization FIG. 7 Multidirectional–Overall Magnetization FIG. 8 Cable Magnetization E 709 12 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 14. AC, or full-wave rectified AC. A permanent magnet can also introduce a magnetic field in the part but its use is restricted (see 6.3.1). 13. Direction of Magnetic Fields 13.1 Discontinuity Orientation vs. Magnetic Field Direction—Since indications are not normally obtained when discontinuities are parallel to the magnetic field, and since indications may occur in various or unknown directions in a part, each part must be magnetized in at least two directions approximately at right angles to each other as noted in 5.3.2. On some parts circular magnetization may be used in two or more directions, while on others both circular and longitudinal magnetization are used. A multidirectional field can also be employed to achieve part magnetization in more than one direction. 13.2 Circular Magnetization—Circular magnetization (Fig. 10) is the term used when electric current is passed through a part, or by use of a central conductor (see 12.3.3.2) through a central opening in the part, inducing a magnetic field at right angles to the current flow. 13.3 Toroidal Magnetization—When magnetizing a part with a toroidal shape, such as a solid wheel or the disk with a center opening, an induced field that is radial to the disk is most useful for the detection of discontinuities in a circumferential direction. In such applications this field may be more effective than multiple shots across the periphery. 13.4 Longitudinal Magnetization—Longitudinal magnetiza- tion (Fig. 11) is the term used when a magnetic field is generated by an electric current passing through a multiturn, Fig. 12, or laminated coil, Fig. 13, which encloses the part or section of the part to be examined. 13.5 Multidirectional Magnetization—Multidirectional magnetization may be used to fulfill the requirement for (a) Use of Central Conductor on Multipart Magnetization (b) Use of Central Conductor for Localized Magnetization (c) Use of a Special Induced Current Fixture FIG. 9 Central Conductor Induced Magnetization FIG. 10 Circular Magnetization E 709 13 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 15. magnetization in two directions if it is demonstrated that it is effective in all areas. Test parts in accordance with 20.8.2 or shims manufactured to the requirements of AS 5371, or as otherwise approved by the Level III and the Cognizant Engineering Organization, may be used to verify field direc- tion, strength, and balance in multidirectional magnetization. Balance of the field intensity is critical. The field intensity shall be balanced in all directions. The particle application must be timed so that the magnetization levels reach full value in all directions, while the particles are mobile on the surface under examination. (Refer to Fig. 14.) 13.5.1 When actual parts with known defects are used, the number and orientation(s) of the defects (for example, axial, longitudinal, circumferential, etc.) should be noted. The mag- netic field intensity can be considered as being properly balanced when all noted defects can be readily identified with particle indications. 13.5.2 The wet continuous method must be used when performing multidirectional magnetization. 14. Magnetic Field Strength 14.1 Magnetizing Field Strengths—To produce interpret- able indications, the magnetic field in the part must have sufficient strength and proper orientation. For the indications to be consistent, this field strength must be controlled within reasonable limits, usually 625 %. Factors that affect the strength of the field are the size, shape, section thickness, material of the part/piece, and the technique of magnetization. Since these factors vary widely, it is difficult to establish rigid rules for magnetic field strengths for every conceivable con- figuration. 14.2 Establishing Field Strengths—Sufficient magnetic field strength can be established by: 14.2.1 Known Discontinuities—Experiments with similar/ identical parts having known discontinuities. 14.2.2 Artificial Discontinuities—The “pie” field indicator (Fig. 15) and notched shims (Appendix X1) are artificial discontinuities. Other types of artificial flaws are available and may be selected as appropriate. See 20.8. 14.2.3 Hall-effect Probe-Tangential Field Strengths— Tangentially applied field strengths, as measured with a Hall- effect probe/sensor, in the range from 30 to 60 G (2.4 to 4.8 kAM−1 ) should be adequate. See 20.8. Under some circum- stances some fields in the range from 10 to 150 G may be required. 14.2.4 Using Empirical Formulas—Section 14.3 has four empirical formulas for establishing magnetic field strengths; they are rules of thumb. As such, they must be used with judgment. Their use may lead to: 14.2.4.1 Over magnetization, which causes excessive par- ticle background that makes interpretation more difficult if not impossible. FIG. 11 Longitudinal Magnetization FIG. 12 Magnetic Field Produced by an Air Core Coil FIG. 13 Magnetic Field Produced by a Laminated Core Coil FIG. 14 Multidirectional Magnetization FIG. 15 Magnetic Field Indicator E 709 14 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 16. 14.2.4.2 Poor coverage. 14.2.4.3 Poor choice of test geometries. 14.2.4.4 A combination of the above. 14.3 Guidelines for Establishing Magnetic Fields—The fol- lowing guidelines can be effectively applied for establishing proper levels of circular and longitudinal magnetization. 14.3.1 Circular Magnetization—Magnetic Field Strength: 14.3.1.1 Direct Circular Magnetization—When magnetiz- ing by passing current directly through the part the nominal current should be 300–800 A/in. of part diameter (12 to 32 A/mm). The diameter of the part shall be taken as the greatest distance between any two points on the outside circumference of the part. Currents will normally be 500 A/in. (20 A/mm) or lower, with the higher currents up to 800 A/in. (32 A/mm) being used to examine for inclusions or to examine low- permeability alloys. Amperages of less than 300 A/in. may be used when part configuration dictates and approval is obtained from the Level III and the Cognizant Engineering Organiza- tion. 14.3.1.2 Central Conductor Induced Magnetization— Central conductors are widely used in magnetic particle examination to provide: (1) A circular field on both the inside surface and outside surface of tubular pieces that cannot be duplicated by the direct current technique. (2) A non-contact means of part magnetization virtually eliminating the possibility of arc burning the material, as can be the case with current flow through contacts, such as prods or clamps. (3) Substantial processing advantages over direct contact techniques on ring-shaped parts. (4) In general it is desirable to centrally locate a central conductor to permit the entire circumference of the part to be processed at one time. The resulting field is concentric relative to the axis of the piece and is maximum at the inside surface. The strength of the magnetic field should be verified by the means discussed in 20.8. With a centrally located central conductor, the magnetizing current requirements would be the same as a solid piece having the same outside diameter. (5) When using offset central conductors the conductor passing through the inside of the part is placed against an inside wall of the part. The current shall be from 12 A per mm of part diameter to 32 A per mm of part diameter (300 to 800 A/in.). The diameter of the part shall be taken as the largest distance between any two points on the outside circumference of the part. Generally currents will be 500 A/in. (20 A per mm) or lower with the higher currents (up to 800 A/in.) being used to examine for inclusions or to examine low permeability alloys such as precipitation-hardening steels. For examinations used to locate inclusions in precipitation-hardening steels even higher currents, up to 1000 A/in. (40 A per mm) may be used. The distance along the part circumference which may be effectively examined shall be taken as approximately four times the diameter of the central conductor, as illustrated in Fig. 16. The entire circumference shall be examined by rotating the part on the conductor, allowing for approximately a 10 % magnetic field overlap. Less overlap, different current levels, and larger effective regions (up to 360°) may be used if the presence of suitable field levels is verified. 14.3.1.3 Localized Magnetization: (1) Using Prods—When using prods on material 3⁄4 in. (19 mm) in thickness or less, 90 to 115 A/in. of prod spacing (3.5 to 4.5 A/mm) shall be used. For material greater than 3⁄4 in. (19 mm) in thickness, 100 to 125 A/in. of prod spacing should be used. Prod spacing shall not be less than 2 in. (50 mm) or greater than 8 in. (200 mm). The effective width of the magnetizing field when using prods is one fourth of the prod spacing on each side of a line through the prod centers. (2) Using Yokes—The field strength of a yoke (or a permanent magnet) can be empirically determined by measur- ing its lifting power (see 20.3.6). If a Hall-effect probe is used, it shall be placed on the surface midway between the poles. 14.3.2 Air-Core Coil Longitudinal Magnetization— Longitudinal part magnetization is produced by passing a current through a multiturn coil encircling the part or section of the part to be examined. A magnetic field is produced parallel to the axis of the coil. The unit of measurement is ampere turns (NI) (the actual amperage multiplied by the number of turns in the encircling coil or cable). The effective field extends on either side of the coil a distance approximately equal to the radius of the coil being employed. Long parts should be examined in sections not to exceed this length. There are four empirical longitudinal magnetization formulas employed for using encircling coils, the formula to be used depending on the fill factor. The formulas are included for historical continuity only. If used its use should be limited to simple shaped parts. It would be quicker and more accurate to use a Gauss (Tesla) meter, lay its probe on the part and measure the field rather than to calculate using the formulas. 14.3.2.1 Low Fill-Factor Coils—In this case, the cross- sectional area of the fixed encircling coil greatly exceeds the cross-sectional area of the part (less than 10 % coil inside diameter). For proper part magnetization, such parts should be placed well within the coils and close to the inside wall of the coil. With this low fill-factor, adequate field strength for eccentrically positioned parts with a length-over-diameter ratio FIG. 16 Approximate Effective Region of Examination When Using an Offset Central Conductor (Threader Bar) E 709 15 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 17. (L/D) between 3 and 15 is calculated from the following equations:12 (1) Parts With Low Fill-Factor Positioned Close to Inside Wall of Coil: NI 5 K/~L/D! ~610 %! (1) where: N = number of turns in the coil, I = coil current to be used, amperes (A), K = 45 000 (empirically derived constant), L = part, length, in., (see Note), D = part diameter, in.; for hollow parts, see 14.3.2.4, and NI = ampere turns. For example, a part 15 in. (38.1 cm) long with 5-in. (12.7-cm) outside diameter has an L/D ratio of 15/5 or 3. Accordingly, the ampere turn requirement (NI = 45 000/3) to provide adequate field strength in the part would be 15 000 ampere turns. If a five-turn coil or cable is used, the coil amperage requirements would be (I = 15 000/5) = 3000 A (610 %). A500 turn coil would require 30 A (610 %). (2) Parts with a Low Fill-Factor Positioned in the Center of the Coil: NI 5 KR/$~6L/D! 2 5%~610 %! (2) where: N = number of turns in the coil, I = coil current to be used, A, K = 43 000 (empirically derived constant), R = coil radius, in., L = part length, in. (see Note), D = part diameter, in., for hollow parts (see 14.3.2.4), and NI = ampere turns. For example, a part 15 in. (38.1 cm) long with 5-in. (12.7-cm) outside diameter has a L/D ratio of 15/5 or 3. If a five-turn 12-in. diameter (6-in. radius) (30.8-cm diameter (15.4-cm radius)) coil or cable is used, (1) the ampere turns requirement would be as follows: NI 5 ~43 000 3 6! ~~6 3 3! 2 5! or 19 846 and (2) the coil amperage requirement would be as follows: 19 846 5 or 3 969 A ~610 %! 14.3.2.2 Intermediate Fill-Factor Coils—When the cross section of the coil is greater than twice and less than ten times the cross section of the part being examined: NI 5 ~NI!hf ~10 2 Y! 1 ~NI!lf ~Y 2 2!/8 (3) where: NIhf = value of NI calculated for high fill-factor coils using Eq 3, NIlf = value of NI calculated for low fill-factor coils using Eq 1 or Eq 2, and Y = ratio of the cross-sectional area of the coil to the cross section of the part. For example, if the coil has an inside diameter of 10 in. (25.4 cm) and part (a bar) has an outside diameter of 5 in. (12.2 cm) Y 5 ~p~5!2 !/~p~2.5!2 ! 5 4 14.3.2.3 High Fill-Factor Coils—In this case, when fixed coils or cable wraps are used and the cross-sectional area of the coil is less than twice the cross-sectional area (including hollow portions) of the part, the coil has a high fill-factor. (1) For Parts Within a High Fill-Factor Positioned Coil and for Parts with an L/D ratio equal to or greater than 3: NI 5 K $~L/D! 1 2% ~610 %! where: N = number of turns in the coil or cable wrap, I = coil current, A, K = 35 000 (empirically derived constant), L = part length, in., D = part diameter, in., and NI = ampere turns. For example, the application of Eq 3 can be illustrated as follows: a part 10 in. (25.4 cm) long-with 2-in. (5.08-cm) outside diameter would have an L/D ratio of 5 and an ampere turn requirements of NI = 35 000/(5 + 2) or 5000 (610 %) ampere turns. If a five-turn coil or cable wrap is employed, the amperage requirement is 5000/5 or 1000 A (610 %). NOTE 1—For L/D ratios less than 3, a pole piece (ferromagnetic material approximately the same diameter as part) should be used to effectively increase the L/D ratio or utilize an alternative magnetization method such as induced current. For L/D ratios greater than 15, a maximum L/D value of 15 should be used for all formulas cited above. 14.3.2.4 L/D Ratio for a Hollow Piece—When calculating the L/D ratio for a hollow piece, D shall be replaced with an effective diameter Deff calculated using: Deff 5 2@~At 2 Ah!/p#1/2 where: At = total cross-sectional area of the part, and Ah = cross-sectional area of the hollow portion(s) of the part. Deff 5 @~OD!2 2 ~ID!2 #1/2 where: OD = outside diameter of the cylinder, and ID = inside diameter of the cylinder. 15. Application of Dry and Wet Magnetic Particles 15.1 Dry Magnetic Particles: 15.1.1 Magnetic Fields for Dry Particles—Dry magnetic powders are generally applied with the continuous magnetizing 12 These equations are included for historical continuity only. It is faster to buy a Tesla meter, lay the probe on the part and measure the field strength than calculating using the equations. E 709 16 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 18. techniques utilizing AC or half-wave rectified AC or yoke magnetization. A current duration of at least 1⁄2s should be used. The current duration should be short enough to prevent any damage from overheating or from other causes. It should be noted that AC and half-wave rectified AC impart better particle mobility to the powder than DC or full-wave rectified AC. Dry magnetic powders are widely used for magnetic particle examination of large parts as well as on localized areas such as welds. Dry magnetic particles are widely used for oil field applications and are frequently used in conjunction with capacitor discharge style equipment and the residual method. 15.1.2 Dry Powder Application—Dry powders should be applied in such a manner that a light uniform, dust-like coating settles upon the surface of the part/piece while it is being magnetized. Dry particles must not be applied to a wet surface; they will have limited mobility. Neither should they be applied where there is excessive wind. The preferred application technique suspends the particles in air in such a manner that they reach the part surface being magnetized in a uniform cloud with a minimum of force. Usually, specially designed powder blowers and hand powder applicators are employed (Fig. 1(b) and Fig. 4). Dry particles should not be applied by pouring, throwing, or spreading with the fingers. 15.1.3 Excess Powder Removal—Care is needed in both the application and removal of excess dry powder. While the magnetizing current is present, care must be exercised to prevent the removal of particles attracted by a leakage field that may prove to be a relevant indication of a discontinuity. 15.1.4 Near-surface Discontinuities Powder Patterns—In order to recognize the broad, fuzzy, weakly held powder patterns produced by near-surface discontinuities, it is essential to observe carefully the formation of indications while the powder is being applied and also while the excess is being removed. Sufficient time for indication formation and exami- nation should be allowed between successive magnetization cycles. 15.2 Wet Particle Application—Wet magnetic particles, fluorescent or nonfluorescent, suspended in a vehicle at a recommended concentration may be applied either by spraying or flowing over the areas to be inspected during the application of the magnetizing field current (continuous technique) or after turning off the current (residual technique). Proper sequencing of operation (part magnetization and timing of bath applica- tion) is essential to indication formation and retention. For the continuous technique multiple current shots should be applied. The last shot should be applied after the particle flow has been diverted and while the particle bath is still on the part. A single shot may be sufficient. Care should be taken to prevent damage to a part due to overheating or other causes. Since fine or weakly held indications on highly finished or polished surfaces may be washed away or obliterated, care must be taken to prevent high-velocity flow over critical surfaces and to cut off the bath application before removing the magnetic field. Since a residual field has a lower intensity than a continuous field, less pronounced indications tend to form. 15.3 Magnetic Slurry/Paints—Magnetic slurry/paints are applied to the part with a brush before or during part magne- tization. Indications appear as a dark line against a light silvery background. Magnetic slurry is ideal for overhead or under- water magnetic particle examination. 15.4 Magnetic Polymers—Magnetic polymers are applied to the test part as a liquid polymer suspension. The part is then magnetized, the polymer is allowed to cure, and the elastic coating is removed from the test surface for examination. Care must be exercised to ensure that magnetization is completed within the active migration period of the polymer which is usually about 10 min. This method is particularly applicable to areas of limited visual access such as bolt holes. Detailed application and use instructions of the manufacturer should be followed for optimum results. 16. Interpretation of Indications 16.1 Valid Indications—All valid indications formed by magnetic particle examination are the result of magnetic leakage fields. Indications may be relevant (16.1.1), nonrel- evant (16.1.2), or false (16.1.3). 16.1.1 Relevant Indications—Relevant indications are pro- duced by leakage fields which are the result of discontinuities. Relevant indications require evaluation with regard to the acceptance standards agreed upon between the manufacturer/ test agency and the purchaser (see Annex A1). 16.1.2 Nonrelevant Indications—Nonrelevant indications can occur singly or in patterns as a result of leakage fields created by conditions that require no evaluation such as changes in section (like keyways and drilled holes), inherent material properties (like the edge of a bimetallic weld), magnetic writing, etc. 16.1.3 False Indications—False indications are not the result of magnetic forces. Examples are particles held mechani- cally or by gravity in shallow depressions or particles held by rust or scale on the surface. 17. Recording of Indications 17.1 Means of Recording—When required by a written procedure, permanent records of the location, type, direction, length(s), and spacing(s) of indications may be made by one or more of the following means. 17.1.1 Sketches—Sketching the indication(s) and their loca- tions. 17.1.2 Transfer (Dry Powder Only)—Covering the indica- tion(s) with transparent adhesive-backed tape, removing the tape with the magnetic particle indication(s) adhering to it, and placing it on paper or other appropriate background material indicating locations. 17.1.3 Strippable Film (Dry Powder Only)—Covering the indication(s) with a spray-on strippable film that fixes the indication(s) in place. When the film is stripped from the part, the magnetic particle indication(s) adhere to it. 17.1.4 Photographing—Photographing the indications themselves, the tape, or the strippable film reproductions of the indications. 17.1.5 Written Records—Recording the location, length, orientation, and number of indications. 17.2 Accompanying Information—A record of the proce- dure parameters listed below as applicable should accompany the inspection results: E 709 17 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 19. 17.2.1 Method Used—Magnetic particle method (dry, wet, fluorescent, etc.). 17.2.2 Magnetizing Technique—Magnetizing technique (continuous, true-continuous, residual). 17.2.3 Current Type—Magnetizing current (AC, half-wave rectified or full-wave rectified AC, etc.). 17.2.4 Field Direction—Direction of magnetic field (prod placement, cable wrap sequence, etc.). 17.2.5 Field Strength—Magnetic current strength (ampere turns, amperes per millimetre (inch) of prod spacing, lifting force, etc.). 18. Demagnetization 18.1 Applicability—All ferromagnetic material will retain some residual magnetism, the strength of which is dependent on the retentivity of the part. Residual magnetism does not affect the mechanical properties of the part. However, a residual field may cause chips, filing, scale, etc. to adhere to the surface affecting subsequent machining operations, painting, or plating. Additionally, if the part will be used in locations near sensitive instruments, high residual fields could affect the operation of these instruments. Furthermore, a strong residual magnetic field in a part to be arc welded could interfere with welding. Residual fields may also interfere with later magnetic particle examination. Demagnetization is required only if specified in the drawings, specification, or purchase order. When required, an acceptable level of residual magnetization and the measuring method shall also be specified. See 18.3. 18.2 Demagnetization Methods—The ease of demagnetiza- tion is dependent on the coercive force of the metal. High retentivity is not necessarily related to high coercive force in that the strength of the residual field is not always an indicator of ease of demagnetizing. In general, demagnetization is accomplished by subjecting the part to a field equal to or greater than that used to magnetize the part and in nearly the same direction, then continuously reversing the field direction while gradually decreasing it to zero. 18.2.1 Withdrawal from Alternating Current Coil—The fastest and most simple technique is to pass the part through a high intensity alternating current coil and then slowly withdraw the part from the field of the coil. A coil of 5000 to 10 000 ampere turns is recommended. Line frequency is usually from 50 to 60 Hz alternating current. The piece should enter the coil from a 12-in. (300-mm) distance and move through it steadily and slowly until the piece is at least 36 in. (900 mm) beyond the coil. Care should be exercised to ensure that the part is entirely removed from the influence of the coil before the demagnetizing force is discontinued, otherwise the demagne- tizer may have the reverse effect of magnetizing the part. This should be repeated as necessary to reduce the residual field to an acceptable level. See 18.3. Small parts of complex figura- tion can be rotated and tumbled while passing through the field of the coil. 18.2.2 Decreasing Alternating Current—An alternative technique for part demagnetization is subjecting the part to the field while gradually reducing its strength to a desired level. 18.2.3 Demagnetizing With Yokes—Alternating current yokes may be used for local demagnetization by placing the poles on the surface, moving them around the area, and slowly withdrawing the yoke while it is still energized. 18.2.4 Reversing Direct Current—The part to be demagne- tized is subjected to consecutive steps of reversed and reduced direct current magnetization to a desired level. (This is the most effective process of demagnetizing large parts in which the alternating current field has insufficient penetration to remove the internal residual magnetization.) This technique requires special equipment for reversing the current while simultaneously reducing it in small increments. 18.3 Extent of Demagnetization—The effectiveness of the demagnetizing operation can be indicated by the use of appropriate magnetic field indicators or field strength meters. Caution: A part may retain a strong residual field after having been circularly magnetized and exhibit little or no external evidence of this field. Therefore, the circular magnetization should be conducted before longitudinal magnetization if complete demagnetization is required. 18.3.1 After demagnetization residual fields should not exceed 3 G (240 Am−1 ) anywhere in the piece, absolute value, unless otherwise agreed upon or as specified on the engineering drawing or in the contract, purchase order, or specification. 19. Post Examination Cleaning 19.1 Particle Removal—Post-test cleaning is necessary where magnetic particle material(s) could interfere with sub- sequent processing or with service requirements. The pur- chaser should specify when post-test cleaning is needed and the extent required. 19.2 Means of Particle Removal—Typical post-test clean- ing techniques employed are: (a) the use of compressed air to blow off unwanted dry magnetic particles; (b) drying of wet particles and subsequent removal by brushing or with com- pressed air; (c) removal of wet particles by flushing with solvent; and (d) other suitable post-examination cleaning techniques may be used if they will not interfere with subse- quent requirements. 20. Evaluation of System Performance/Sensitivity 20.1 Contributing Factors—The overall performance/ sensitivity of a magnetic particle examination system is depen- dent upon the following: 20.1.1 Operator capability, if a manual operation is in- volved. 20.1.2 Control of process steps. 20.1.3 The particles or suspension, or both. 20.1.4 The equipment. 20.1.5 Visible light level. 20.1.6 Black light monitoring where applicable. 20.1.7 Magnetic field strength. 20.1.8 Field direction or orientation. 20.1.9 Residual field strength. 20.1.10 These factors should all be controlled individually. 20.2 Maintenance and Calibration of Equipment—The magnetic particle equipment employed should be maintained in proper working order at all times. The frequency of verification calibration, usually every six months, see Table 2, or whenever a malfunction is suspected, should be specified in the written procedures of the testing facility. Records of the checks and results provide useful information for quality control purposes E 709 18 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 20. and should be maintained. In addition, any or all of the tests described should be performed whenever a malfunction of the system is suspected. Calibration tests should be conducted in accordance with the specifications or documents that are applicable. 20.3 Equipment Checks—The following tests are recom- mended for ensuring the accuracy of magnetic particle mag- netizing equipment. 20.3.1 Ammeter Accuracy—The equipment meter readings should be compared to those of a control test meter incorpo- rating a shunt or current transformer connected to monitor the output current. The accuracy of the entire control test meter arrangement should be verified at six-month intervals or as agreed upon between the purchaser and supplier by a means traceable to the National Institute of Standards and Technology (NIST). Comparative readings shall be taken at a minimum of three output levels encompassing the usable range. The equip- ment meter reading shall not deviate by more than6 10 % of full scale relative to the actual current values as shown by the test meter. Caution: When measuring half-wave rectified AC, the direct current reading of a conventional DC test meter reading must be doubled. 20.3.2 Timer Control Check—On equipment utilizing a timer to control the duration of the current flow, the timer should be checked for accuracy as specified in Table 2 or whenever a malfunction is suspected. 20.3.3 Magnetic Field Quick Break Check—On equipment that has a quick break feature, the functioning of this circuit should be checked and verified. This test may be performed using a suitable oscilloscope or a simple test device usually available from the manufacturer. On electronic power packs or machines, failure to achieve indication of a“ quick break” would indicate that a malfunction exists in the energizing circuit. 20.3.4 Equipment Current Output Check—To ensure the continued accuracy of the equipment, ammeter readings at each transformer tap should be made with a calibrated ammeter-shunt combination. This accessory is placed in series with the contacts. The equipment shunt should not be used to check the machine of which it is a part. For infinite current control units (non-tap switch), settings at 500-A intervals should be used. Variations exceeding 610 % from the equip- ment ammeter readings indicate the equipment needs service or repair. 20.3.5 Internal Short Circuit Check—Magnetic particle equipment should be checked periodically for internal short circuiting. With the equipment set for maximum amperage output, any deflection of the ammeter when the current is activated with no conductor between the contacts is an indica- tion of an internal short circuit. 20.3.6 Electromagnetic Yoke Lifting Force Test—The mag- netizing force of a yoke (or a permanent magnet) should be tested by determining its lifting power on a steel plate. See Table 3. The lifting force relates to the electromagnetic strength of the yoke. 20.3.7 Powder Blower—The performance of powder blow- ers used to apply the dry magnetic particles should be checked at routine intervals or whenever a malfunction is suspected. The check should be made on a representative test part. The blower should coat the area under test with a light, uniform dust-like coating of dry magnetic particles and have sufficient force to remove the excess particles without disturbing those particles that are evidence of indications. Necessary adjust- ments to the blower’s flow rate or air velocity should be made in accordance with the manufacturer’s recommendations. 20.4 Examination Area Light Level Control: 20.4.1 Visible Light Intensity—Light intensity in the exami- nation area should be checked at specified intervals with the designated light meter at the surface of the parts being examined. See Table 2. 20.4.2 Black (ultraviolet) Light Intensity—Black light in- tensity and wavelength should be checked at the specified intervals but not to exceed one-week intervals and whenever a bulb is changed. Reflectors and filters should be cleaned daily and checked for integrity. See Table 2. Cracked or broken UV filters shall be replaced immediately. Defective bulbs which radiate UV energy must also be replaced before further use. 20.5 Dry Particle Quality Control Tests—In order to assure uniform and consistent performance from the dry magnetic powder selected for use, it is advisable that all incoming powders be certified or tested for conformance with quality control standards established between the user and supplier. 20.5.1 Contamination: 20.5.1.1 Degradation Factors—Dry magnetic particles are generally very rugged and perform with a high degree of consistency over a wide process envelope. Their performance, however, is susceptible to degradation from such contaminants as moisture, grease, oil, rust and mill scale particles, nonmag- netic particles such as foundry sand, and excessive heat. These contaminants will usually manifest themselves in the form of particle color change and particle agglomeration, the degree of TABLE 2 Recommended Verification Intervals Item Maximum Time Between VerificationsA Reference Paragraphs Lighting: Visible light intensity 1 week 7.1.1 Black light intensity 1 week 7.1.2 Background visible light intensity 1 weekA 7.1.1 System performance using test piece or ring specimen of Fig. 17 1 day 20.8.3 Wet particle concentration 8 h, or every shift change 20.6 Wet particle contamination 1 week 20.6.4 Water break test 1 day 20.7.5 Equipment calibration/check: Ammeter accuracy 6 months 20.3.1 Timer control 6 months 20.3.2 Quick break 6 months 20.3.3 Dead weight check 6 months 20.3.6 Light meter checks 6 months 20.4 A Note—The maximum time between verifications may be extended when substantiated by actual technical stablity/reliability data. TABLE 3 Minimum Yoke Lifting Force Type Current Yoke Pole Leg Spacing 50 to 100 mm (2 to 4 in.) 100 to 150 mm (4 to 6 in.) AC DC 45 N (10 lb) 135 N (30 lb) 225 N (50 lb) E 709 19 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 21. which will determine further use of the powder. Over-heated dry particles can lose their color, thereby reducing the color contrast with the part and thus hinder part examination. Particle agglomeration can reduce particle mobility during processing, and large particle agglomerates may not be retained at an indication. 20.5.1.2 Ensuring Particle Quality—To ensure against del- eterious effects from possible contaminants, it is recommended that a routine performance/sensitivity test be conducted (see 20.8.3). 20.6 Wet Particle Quality Control Tests—The following tests for wet magnetic particle suspensions should be con- ducted at startup and at regular intervals to assure consistent performance. See Table 2. Since bath contamination will occur as the bath is used, monitoring the working bath at regular intervals is essential. 20.6.1 Determining Bath Concentration—Bath concentra- tion and sometimes bath contamination are determined by measuring its settling volume through the use of a Test Method D 1966 pear-shaped centrifuge tube with a 1-mL stem (0.05-mL divisions) for fluorescent particle suspensions or a 1.5-mL stem (0.1-mL divisions) for nonfluorescent suspen- sions. Before sampling, the suspension should be run through the recirculating system for at least 30 min to ensure thorough mixing of all particles which could have settled on the sump screen and along the sides or bottom of the tank. Take a 100-mL portion of the suspension from the hose or nozzle, demagnetize and allow it to settle for approximately 60 min with petroleum distillate suspensions or 30 min with water- based suspensions before reading. The volume settling out at the bottom of the tube is indicative of the particle concentration in the bath. 20.6.2 Sample Interpretation—If the bath concentration is low in particle content, add a sufficient amount of particle materials to obtain the desired concentration; if the suspension is high in particle content, add sufficient vehicle to obtain the desired concentration. If the settled particles appear to be loose agglomerates rather than a solid layer, take a second sample. If still agglomerated, the particles may have become magnetized; replace the suspension. 20.6.3 Settling Volumes—For fluorescent particles, the rec- ommended settling volume (see 15.2) is from 0.1 to 0.4 mL in a 100-mL bath sample and from 1.2 to 2.4 mL per 100 mL of vehicle for non-fluorescent particles, unless otherwise ap- proved by the Cognizant Engineering Organization (CEO). Refer to appropriate AMS document (3041, 3042, 3043, 3044, 3045, and/or 3046). For dual-colored particles, the recom- mended settling volume should be determined by the perfor- mance requirements and lighting environment of a given application as recommended by the manufacturer. See 8.5.5. 20.6.4 Bath Contamination—Both fluorescent and nonfluo- rescent suspensions should be checked periodically for con- taminants such as dirt, scale, oil, lint, loose fluorescent pig- ment, water (in the case of oil suspensions), and particle agglomerates which can adversely affect the performance of the magnetic particle examination process. See Table 2. 20.6.4.1 Carrier Contamination—For fluorescent baths, the liquid directly above the precipitate should be examined with black light. The liquid will have a little fluorescence. Its color can be compared with a freshly made-up sample using the same materials or with an unused sample from the original bath that was retained for this purpose. If the “used” sample is noticeably more fluorescent than the comparison standard, the bath should be replaced. 20.6.4.2 Particle Contamination—The graduated portion of the tube should be examined under black light if the bath is fluorescent and under visible light (for both fluorescent and nonfluorescent particles) for striations or bands, differences in color or appearance. Bands or striations may indicate contami- nation. If the total volume of the contaminates, including bands or striations exceeds 30 % of the volume of magnetic particles, or if the liquid is noticeably fluorescent (see 20.6.4.1), the bath should be replaced. 20.6.5 Particle Durability—The durability of both the fluo- rescent and nonfluorescent magnetic particles in suspension should be checked periodically to ensure that the particles have not degraded due to chemical attack from the suspending oil or conditioned water vehicles or mechanically degraded by the rotational forces of the recirculating pump in a wet horizontal magnetic particle unit. Fluorescent magnetic particle break- down in particular can result in a decrease in sensitivity and an increase in nonmagnetic fluorescent background. Lost fluores- cent pigment can produce false indications that can interfere with the examination process. 20.6.6 Fluorescent Brightness—It is important that the brightness of fluorescent magnetic particle powder be main- tained at the established level so that indication and back- ground brightness can be kept at a relatively constant level. Variations in contrast can noticeably affect test results. Lack of adequate contrast is generally caused by: 20.6.6.1 An increase in contamination level of the vehicle increasing background fluorescence, or 20.6.6.2 Loss of vehicle because of evaporation, increasing concentration, or 20.6.6.3 Degradation of fluorescent particles. A change in contrast ratio can be observed by using a test ring specimen with an etched surface. 20.6.7 Performance/Sensitivity—Failure to find a known discontinuity in a part or obtain the specified indications on the test ring (see 20.8.3) indicates a need for changing of the entire bath. If a part was used, it must have been ultrasonically cleaned so that no fluorescent background can be detected when viewed under black light with a surface intensity of at least 1000 µW/cm2 . If any background is noted that interferes with either detection or interpretation, the bath should be drained and a new suspension made. 20.6.8 Magnetic Stripe Cards—The encoded pattern on the magnetic stripes of magnetic stripe cards may serve as a test piece for the evaluation of particle sensitivity. Particles are attracted to magnetic gradients formed when the stripe has been encoded. See Appendix X2 for further information. 20.7 Bath Characteristics Control: 20.7.1 Oil Bath Fluids—Properties of oil-bath fluids are described in AMS 2641 or A-A–59230. 20.7.2 Water Bath Fluids—Properties of conditioned water- bath fluids are described in AS 4792. E 709 20 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 22. 20.7.3 Viscosity—The viscosity of the suspension should not exceed 5 mm2 /s (5.0 cSt), at any temperature at which the bath may be used, when tested in accordance with Test Method D 445. 20.7.4 Flash Point—The flash point of wet magnetic par- ticle light petroleum distillate suspension should be a minimum of 200°F (93°C); use Test Method D 93. 20.7.5 Water Break Test for Conditioned Water Vehicles— Properly conditioned water will provide proper wetting, par- ticle dispersion, and corrosion protection. The water break test should be performed by flooding a part, similar in surface finish to those under test, with suspension, and then noting the appearance of the surface of the part after the flooding is stopped. If the film of suspension is continuous and even all over the part, sufficient wetting agent is present. If the film of suspension breaks, exposing bare surfaces of the part, and the suspension forms many separate droplets on the surface, more wetting agent is needed or the part has not been sufficiently cleaned. 20.7.6 pH of Conditioned Water Vehicles—The pH of the conditioned water bath should be between 7.0 and 10.5 as determined by a suitable pH meter or special pH paper. 20.8 Verifying System Performance: System performance tests must be conducted in accordance with a written procedure so that the test is performed in the same manner each time. 20.8.1 Production Test Parts with Discontinuities—A prac- tical way to evaluate the performance and sensitivity of the dry or wet magnetic particles or overall system performance, or both, is to use representative test parts with known disconti- nuities of the type and severity normally encountered during actual production inspection. However, the usefulness of such parts is limited because the orientation and magnitude of the discontinuities cannot be controlled. The use of flawed parts with gross discontinuities is not recommended. Caution—If such parts are used, they must be thoroughly cleaned and demagnetized after each use. 20.8.2 Fabricated Test Parts with Discontinuities—Often, production test parts with known discontinuities of the type and severity needed for evaluation are not available. As an alter- native, fabricated test specimens with discontinuities of vary- ing degree and severity can be used to provide an indication of the effectiveness of the dry or wet magnetic particle examina- tion process. 20.8.3 Test Plate—A magnetic particle system performance test plate, such as shown in Fig. 17 is useful for testing the overall performance of wet or dry techniques using prods and yokes. Recommended minimum dimensions are ten inches per side and nominal thickness of one inch. Discontinuities can be formed by controlled heating/cooling, EDM notches, artificial discontinuities per 14.2.2 or other means. NOTE 2—Notches are to be filled flush to the surface with a noncon- ducting material, such as epoxy, to prevent the mechanical holding of the indicating medium. 20.8.4 Test Ring Specimen—A test (Ketos) ring specimen may also be used in evaluating and comparing the overall performance and sensitivity of both dry and wet, fluorescent and non-fluorescent magnetic particle techniques using a central conductor magnetization technique. Refer to Practice E 1444, Appendix X1. 20.8.4.1 Using the Test Ring—If using the test ring, place a conductor with a diameter between 1 and 1.25 in. (25 and 31 mm) and a length longer than 16 in. (40 cm) through the center of the ring. Center the ring on the length of the conductor. Magnetize the ring circularly by passing the current through the conductor as described in Appendix X1 of Practice E 1444. Gently apply particles to the surface of the ring while the current is flowing. Examine the ring within one minute after current application. The number of hole indications visible should meet or exceed those as specified in Appendix X1 of Practice E 1444. 20.8.5 Magnetic Field Indicators: 20.8.5.1 “Pie” Field Indicator—The magnetic field indica- tor shown in Fig. 15 relies on the slots between the pie shaped segments to show the presence and the approximate direction of the magnetic field. A suitable field strength is indicated when a clearly defined line of magnetic particles forms across the copper face of the indicator (the slots are against the piece) when the magnetic particles are applied simultaneously with the magnetizing force. Failure to obtain an indication can result from: (1) insufficient magnetic field, or (2) the magnetic properties of the material being examined, or both. 20.8.5.2 Slotted Shims—Several types of slotted shims ex- ist. Refer to AS 5371 and to illustrations in Appendix X1. 20.8.6 Half-effect Probe—The Hall-effect probe or sensor measures the tangential field strength (in air adjacent to the part) of the magnetizing force (H) and is calibrated in gauss. The sensor must be used with care. It must be kept close to the part surface. The manufacturer’s instructions should be fol- lowed. These instruments can be used to detect a residual field or measure fields produced during head shots and shots using a central conductor. 21. Procedures 21.1 When specified a procedure should be written for all FIG. 17 Sample of a Magnetic Particle Performance Test Plate. Defects are formed and located in accordance with plate manufacturers’ specifications. E 709 21 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 23. magnetic particle examinations and should include as a mini- mum the following information. A sketch is usually used for illustrating part geometry, techniques, and areas for examina- tion. This sketch may also be used for recording location of magnetic field indicators and for recording location of discon- tinuities. 21.1.1 Area to be examined (entire part or specific area), 21.1.2 Type of magnetic particle material (dry or wet, visible or fluorescent), 21.1.3 Magnetic particle equipment, 21.1.4 Part surface preparation requirements, 21.1.5 Magnetizing process (continuous, true-continuous, residual), 21.1.6 Magnetizing current (alternating, half-wave rectified AC, full-wave rectified AC, direct), 21.1.7 Means of establishing part magnetization (direct- prods, head/tailstock contact or cable wrap, indirect-coil/cable wrap, yoke, central conductor, and so forth), 21.1.8 Direction of magnetic field (circular or longitudinal), 21.1.9 System performance/sensitivity checks, 21.1.10 Magnetic field strength (ampere turns, field density, magnetizing force, and number and duration of application of magnetizing current), 21.1.11 Application of examination media, 21.1.12 Interpretation and evaluation of indications, 21.1.13 Type of records including accept/reject criteria, 21.1.14 Demagnetizing techniques, if required, and 21.1.15 Post-examination cleaning, if required, 21.2 Written Reports—Written reports shall be prepared as agreed upon between the testing agency/department and the purchaser/user. 22. Acceptance Standards 22.1 The acceptability of parts examined by this method is not specified herein. Acceptance standards are a matter of agreement between the manufacturer and the purchaser and should be stated in a referenced contract, specification, or code. 23. Safety 23.1 Those involved with hands-on magnetic particle ex- amination exposure to hazards include: 23.1.1 Electric Shock and Burns—Electric short circuits can cause shock and particularly burns from the high amperages at relatively low voltages that are used. Equipment handling water suspensions should have good electrical grounds. 23.1.2 Flying Particles—Magnetic particles, particularly the dry ones, dirt, foundry sand, rust, and mill scale can enter the eyes and ears when they are blown off the part when applying them to a vertical or overhead surface or when cleaning an examined surface with compressed air. Dry par- ticles are easy to inhale and the use of a dust respirator is recommended. 23.1.3 Falls—A fall from a scaffold or ladder if working on a large structure in the field or shop. 23.1.4 Fire—Ignition of a petroleum distillate bath. 23.1.5 Environment—Doing magnetic particle examination where flammable vapors are present as in a petrochemical plant or oil refinery. Underwater work has its own set of hazards. 23.1.6 Wet Floors—Slipping on a floor wetted with a particle suspension. 23.1.7 Shifting or Dropping of Large Components—Large components, especially those on temporary supports can shift during examination or fall while being lifted. In addition, operators should be alert to the possibility of injury to body members being caught beneath a sling/chain or between head/tail stock and the piece. 23.1.8 Ultraviolet Light Exposure—Ultraviolet light can adversely affect the eyes and skin. Safety goggles designed to absorb UV wavelength radiation are suggested where high intensity blacklight is used. 23.1.9 Materials and Concentrates—The safe handling of magnetic particles and concentrates are governed by the supplier’s Material Safety Data Sheets (MSDS). The MSDS conforming to 29 CFR 1910.1200 or equivalent must be provided by the supplier to any user and must be prepared in accordance with FED-STD-313. 24. Precision and Bias 24.1 The methodology described in the practice will pro- duce repeatable results provided: 24.1.1 The strength of the magnetic flux field in the part/ piece is confirmed and, 24.1.2 The field has the proper orientation with respect to the discontinuities being sought. 24.2 It must be recognized that the surface condition of the material being examined, the material’s magnetic properties, its shape, and control of the factors listed in 20.1 influence the results obtained. 25. Keywords 25.1 dye; evaluation; examination; fluorescent; inspection; magnetic particle; nondestructive; testing E 709 22 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 24. ANNEX (Mandatory Information) A1. TYPICAL MAGNETIC PARTICLE INDICATIONS A1.1 Surface discontinuities with few exceptions produce sharp and distinct magnetic particle indications. Near-surface discontinuities on the other hand produce less distinct or fuzzy magnetic particle indications in comparison to surface discon- tinuities; the magnetic particle indications are broad rather than sharp and the particles are less tightly held. A1.2 Wet Method: A1.2.1 Fluorescent—Indications of surface cracks, surface indications, and an indication of a near surface discontinuity are shown in Figs. A1.1-A1.6. FIG. A1.1 Indications of Surface Cracks (Produced by Central Conductor DC Magnetization) E 709 23 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 25. A1.2.2 Nonfluorescent—Indications of surface cracks are shown in Figs. A1.7-A1.16. A1.3 Dry Method—Indications of surface cracks are shown in Figs. A1.17-A1.23. A1.4 Nonrelevant indications are shown in Figs. A1.24- A1.26. FIG. A1.2 Indications of Surface Cracks (Produced by Central Conductor DC Magnetization) FIG. A1.3 Indications of Surface Cracks (Produced by Central Conductor DC Magnetization) E 709 24 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 26. FIG. A1.4 Surface Indications (Produced by Central Conductor DC Magnetization) FIG. A1.5 Indications of Surface Cracks (Produced by Circular Magnetization DC Continuous) E 709 25 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 27. FIG. A1.6 Indication of a Near-Surface Discontinuity (Produced by Prod Magnetization) FIG. A1.7 Indications of Surface Cracking (Produced by Central Conductor Magnetization DC Continuous) E 709 26 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 28. FIG. A1.8 Indications of Surface Cracking (Produced by Circular Direct Magnetization DC Continuous) FIG. A1.9 Indications of Surface Cracks (Produced by Central Conductor Magnetization DC Continuous) E 709 27 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 29. FIG. A1.10 Indications of Surface Cracks (Produced by Circular Indirect Magnetization DC) FIG. A1.11 Indications of a Near-Surface Discontinuity (Produced by Circular Direct Magnetization AC Continuous) E 709 28 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 30. FIG. A1.12 Indications of Near-Surface Indications (Produced by Circular Direct Magnetization AC Continuous) FIG. A1.13 Magnetic Rubber Indications of Surface Cracks in Aircraft Fastener Holes (Produced by Yoke Magnetization DC Continuous) FIG. A1.14 Magnetic Rubber Indications of Surface Cracks in Aircraft Fastener Holes (Produced by Yoke Magnetization DC Continuous) E 709 29 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 31. FIG. A1.15 Magnetic Slurry Indications of Surface Cracks in Weldment (Produced by Yoke Magnetization, AC Continuous) FIG. A1.16 Magnetic Slurry Indications of Surface Cracks (Produced by Yoke Magnetization, AC Continuous) E 709 30 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 32. FIG. A1.17 Indications of a Near-Surface Discontinuity (Produced by Prod Magnetization, HWDC Continuous) FIG. A1.18 Indications of a Near-Surface Discontinuity (Produced by Prod Magnetization, HWDC Continuous) FIG. A1.19 Indication of Surface Cracks (Produced by Circular Indirect Magnetization, AC Continuous) E 709 31 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 33. FIG. A1.20 Indication of Surface Cracks (Produced by Prod Magnetization, AC Continuous) FIG. A1.21 Indications of Surface Cracks (Produced by Prod Magnetization, DC Continuous) E 709 32 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 34. FIG. A1.22 Indications of Surface Cracks (Produced by Circular Direct Magnetization, AC Continuous) FIG. A1.23 Indications of Surface Cracks (Produced by Central Conductor Magnetization, AC Continuous) E 709 33 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 35. FIG. A1.24 Nonrelevant Indications of Magnetic Writing (Produced by Direct Magnetization, DC Continuous) FIG. A1.25 Nonrelevant Indications Due to Change in Section on a Small Part (Produced by Indirect, Circular Magnetization, DC Continuous) E 709 34 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 36. APPENDIXES (Nonmandatory Information) X1. REFERENCE STANDARD NOTCHED SHIMS FOR MAGNETIC PARTICLE EXAMINATION PER AS 5371 X1.1 The following standard flawed shims are typically used to establish proper field direction and ensure adequate field strength during technique development in magnetic par- ticle examination. The shims of Fig. X1.1 may be used to ensure the establishment and balance of fields in the multidi- rectional magnetization method. X1.1.1 The shims are available in two thicknesses, 0.002 in. (0.05 mm) and 0.004 in. (0.10 mm). Thinner shims are used when the thicker shims cannot conform to the part surface in the area of interest. X1.1.2 The shims are available in two sizes, 0.75 in. (19 mm) square for Figs. X1.1 and X1.2 and 0.79 in. (20 mm) square of Fig. X1.3. The shims of Fig. X1.3 are cut, by the user, into four 0.395 in. (10 mm) square shims for use in restricted areas. X1.1.3 Shims shall be low carbon steel, AMS 5062 or equivalent. X1.1.4 Shims shall be used as specified in AS 5371. Shims are placed in the area(s) of interest with notches toward the surface of the part being examined. Use enough shims or place the shims in multiple areas to ensure proper field directions and strengths are obtained. FIG. A1.26 Nonrelevant Indications of Junction Between Dissimilar Materials (Produced by Coil DC Residual Magnetization) FIG. X1.1 Shim Thicknesses for Shim Types 3C2–234 and 3C4–234 E 709 35 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 37. X2. DEVICES FOR EVALUATION OF MAGNETIC PARTICLE EXAMINATION MATERIALS X2.1 Scope X2.1.1 The purpose of this appendix is to describe the capabilities and use of various devices that may be utilized to monitor and evaluate the performance of materials and systems for magnetic particle examination. X2.2 Magnetic Stripe Cards. The magnetically encoded pattern in magnetic stripes, as on cards used for personal banking, identification and other purposes, can serve as a tool to evaluate magnetic particle inspection materials. Particles are attracted to the magnetic gradients formed in the stripe when the stripe has been magnetically encoded with a pattern of flux reversals. The encoding of the stripe can be controlled to provide gradients of varying magnitude. Particles can be evaluated for sensitivity when observed to see how small a gradient can generate a particle indication. X2.3 Characteristics X2.3.1 Magnetic stripe cards shall be made in accordance with ISO 7810– Identification Cards— Physical Characteris- tics. X2.3.2 The stripe may be made of either low-coercivity (lo-co) or high-coercivity (hi-co) material, as designated by the manufacturer. X2.3.3 A constant encoding pattern, decaying encoding pattern, reverse decaying pattern or other pattern may be encoded into the stripe. See Fig. X2.1 photograph of fluores- cent particle indications of decaying and reverse decaying encoding patterns. FIG. X1.2 Shim Types CX-230 and CX-430 FIG. X1.3 Shim Thicknesses for Shim Types CX4–230 and CX4–430 E 709 36 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 38. X2.4 Use of the Magnetic Stripe Card for Magnetic Particle Material Evaluation X2.4.1 Wet Method Materials—Wet method materials may be poured, sprayed or otherwise applied to the stripe, as they would be used for MPI. Excess bath shall be allowed to flow away from the stripe. The stripe shall be observed under suitable illumination (See Section 7) for the formation of particle indications. Observations shall be noted as to the quantity of particle indications and the clarity thereof. NOTE X2.1—Dark colored non-fluorescent particles may be more readily observed with the use of a white contrast paint applied over the stripe prior to particle evaluation. Particle indications may also be observed and/or permanently recorded per Section 17 (Paragraph 17.1.2 can apply to wet method powder after the fluid has been allowed to evaporate.). X2.4.2 Dry Method Materials—Dry method materials shall be poured, dusted, blown or otherwise applied to the stripe, as they would be used for MPI. Excess powder shall be removed with a gentle blowing action. The stripe shall be observed under suitable illumination (See Section 7) for the formation of particle indications. Observations shall be noted as to the quantity of particle indications and the clarity therof. Refer to Note X2.1 for dark colored particles. X2.4.3 Recording of Indications—Recorded particle indica- tions (See 17.1.2) may serve as material documentation records and standards for material performance. Other material, or the same material at a later time, can be compared at any time to the recorded standard. X2.5 Loss of Indications on the Stripe—There are several circumstances where particle indications may not be visible on the magnetic stripe. When indications are not visible the subject particles shall not be used for inspection unless otherwise verified as being acceptable. X2.5.1 Concentration—The subject wet method particles may not have a sufficient level of concentration. In this case, increase the concentration level of the bath and re-perform the test until the particles demonstrate suitable performance. X2.5.2 Sensitivity—The subject particles may not provide necessary sensitivity. In this case, replace the material with a suitably sensitive material and re-perform the test until the particles demonstrate suitable performance. X2.5.3 Erasure—The stripe has become magnetically erased. In this case, no discernible particle indication will appear. In this case, repeat the test with another card and/or sensitivity test until the particles demonstrate suitable perfor- mance. Either destroy the card with the de-encoded stripe or report it to the manufacturer and follow the manufacturer’s recommendations. X2.6 Precautions X2.6.1 Preparation—The surface of the stripe must be clean of any fluid or foreign matter prior to the application of the MPI material. The encoded stripe shall not be re- magnetized in any manner prior to use or de-magnetized in any manner following its use. X2.6.2 Storage—The surface of the stripe should be cleaned of remaining fluid and particles after the observations of the MPI material have been made. When not in use, the card should be stored away from excessive heat and strong magnetic fields. The American Society for Testing and Materials takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. FIG. X2.1 Example of fluorescent particle indications of a decaying encoding pattern (top track) and a reverse-decaying pattern (bottom track) on the magnetic stripe of a magnetic stripe card. E 709 37 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---
  • 39. This standard is copyrighted by ASTM, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website (www.astm.org). E 709 38 Copyright ASTM International Reproduced by IHS under license with ASTM Licensee=Shell Global Solutions International B.V./5924979112 Not for Resale, 12/27/2005 22:27:47 MST No reproduction or networking permitted without license from IHS --`,`,`,`,,`,``,``,```,``,,,-`-`,,`,,`,`,,`---