SlideShare a Scribd company logo
BIOSENSOR
ARYA H
• Father of Biosensor – Professor Leland C
Clark
• The term ‘biosensor’ is short for “biological
sensor”
• Analytical device used for the detection of
an analyte, that combines a biological
component with a physicochemical detector.
• It is a device incoporating a biological
sensing element either intimately connected
to or integrated within a transducer
• Recognition based on affinity between complementary
structures like:
 Enzyme-substrate, antibody-antigen and receptor-hormone
complex
• Selectivity and specificity depend on biological recognition
systems connected to a suitable transducer.
• It converts a response into an electrical signal
• It detects, records, and transmits information regarding a
physiological change or process
• It determines the presence and concentration of a specific
substance in an test solution
• Main features of biosensors are
stability
cost
sensitivity
reproducibility
Basic principle of biosensor
• Basic principle involved in three element :-
o First biological recognition element which highly specific towards
the biological material analytes produces
o Second transducers detect and transduces signal from biological
target – receptor molecule to electrical signal which is due to
reaction occur
o Third after transduction signal from biological to electrical signal
where its amplification is necessary and takes place and read out in
detector after processing the values are displayed for monitor and
controlling the system
Biosensor , its components, working and  types of biosensors
Components of biosensors
Ist component – Biological element
• The component used to bind the target molecule
• Must be highly specific, stable under storage conditions and
immobilized
• A variety of substance may be used as bioelement in
biosensor
 Microorganism
 Tissue, Cell, Organelle
 Nucleic acid
 Enzyme, Enzyme component
 Receptor
 Antibody
 Plant proteins or lectins
• Functions;
 To interact specifically with a target compound i.e the
compound to be detected
 It must be capable of detecting the presence of a target
compound in the test solution
 The ability of a bio-element to interact with target compound
(specificity) in the basis of biosensor
2nd component – Physiochemical
Transducer
• Acts as an interface, measuring the physical change that
occurs with the reaction at the bioreceptor then transforming
that energy into measureable electrical output
3rd component - Detector
• Signals from the transducer are passed to a microprocessor
where they are amplified and analyzed.
• The data is then converted to concentration units and
transferred to a display or / and data storage device
Biosensor , its components, working and  types of biosensors
• The block diagram of biosensor include
three segments namely sensor, transducer
and associated electrons.
• In the first segment the sensor is a
responsive biological part
• Second segment is the detector part that
changes the resulting signal from the contact
of the analyte and for the results it displays
in an accesible way
• The final section comprises of an amplifier
which is known as signal conditioning circuit,
the display unit as well as the processor.
Basic principle of Biosensor
• The biological material is immobilized and a contact is made
between the immobilized biological material and the
transducer
• The analyte binds to the biological material to form a bound
analyte which inturn produces the electronic response that
can be measured
• Sometimes the analyte is converted to a product which could
be associated with the release of heat, gas(oxygen), electrons,
hydrogen ions.
• The transducer then converts the product linked changes into
electrical signals which can be amplified and measured
Working principle of Biosensor
 Analyte diffuses from the solution to the surface of the
biosensor
 Analyte reacts specifically and efficiently with the biological
component of the biosensor
 This reaction changes the physicochemical properties of the
transducer surface
 This leads to a change in the optical/ electronic properties of
the transducer surface
 The changes in the optical/ electronic properties is measured/
converted into electrical signal, which is detected
• Usually a specific enzyme or preferred biological material is
deactivated by some of the usual methods and the
deactivated biological material is in near contact to the
transducer
• The analyte connects to the biological object to shape a clear
analyte which in turn gives the electronic reaction that can be
calculated
• In some examples, the analyte is changed to a device which
may be connected to the discharge of gas, heat, electron ions
or hydrogen ions
• In this the transducer can alter the device linked converts into
electrical signals which can be changed and calculated
Biosensor , its components, working and  types of biosensors
How does they work…??
• Basically it involve the quantitative analysis of various
substances by converting their biological actions into
measurable signals
• Generally the performance of the biosensors is mostly
dependent on the specificity and sensitivity of the biological
reaction, besides the stability of the enzyme
Ideal Biosensor
1. The output signal must be relevant to measurement
enviornment
2. The functional surface must be compatible with the
transducer
3. High specificity and sensitivity (low interference)
4. Sufficient sensitivity and resolution
5. Surface accuracy and repeatability
6. Sufficient speed of response
7. Sufficient dynamic range
8. Intensivity to enviornmental interference or their effects
must be compensated
Basic characteristics of Biosensor
1. LINEARITY – linearity of the sensor should be high for the
detection of high substrate concentration
2. SENSITIVITY – Value of the electrode response per substrate
concentration
3. SELECTIVITY – Chemicals interference must be minimised for
obtaining the correct result
4. RESPONSE TIME – Time necessary for having 95% of the
response
Typical Sensing Techniques
 Fluorescence
 DNA Microarray
 SPR (Surface Plasma Resistance)
 Impedance Spectroscopy
 SPM (Scanning Probe Microscopy)
 QCM (Quartz Crystal Microbalance)
 SERS (Surface Enhanced Raman Spectroscopy)
Types
 Calorimetric / Thermal Detection Biosensors
 Optical Biosensors
 Resonant Biosensors
 Piezoelectric Biosensors
 Ion Sensitive Biosensors
 Electrochemical Biosensors
* Conductimetric Sensors
* Amperometric Sensors
* Potentiometric Sensors
 Calorimetric / Thermal Detection Biosensors
 Uses Absorption / Production of heat
 Total heat produced / absorbed is α Molar Enthalpy / Total
No. of molecules in the run
 Tem. Measured by Enzyme Thermistors
Advantages
• No need of frequent recalibration
• Intensitive to the optical and electrochemical properties of
the sample
Uses
• Detection of : (1) Pesticides
(2) Pathogenic bacteria
 Ion Sensitive Biosensors
 Surface electrical potential changes when the ion and
semiconductor interact
 Measures the change in potential
 Uses
 Detection of pH
 Electrochemical Biosensors
 Many chemical runs produce or consume ions or electrons causing
some change in the electrical properties of the solution that can be
sensed out and used as a measuring parameter
 Uses
 Detection of :- (1) hybridized DNA
(2) DNA binding drugs
(3) glucose concentration
 Optical Biosensors
 Colorimetric for colour – Measure change in light adsorption
 Photometric for light intensity – Detects the photon input
 Resonant Biosensors
• An Acoustic Wave Transducer is coupled with bioelement
• Measures the change in Resonant Frequency
 Piezoelectric Biosensors
• Uses gold – To detect specific angle at which electron waves
are emitted when the substance is exposed to laser light/
crystals like quartz, which vibrates under the influence of an
electric field
• Change in frequency α Mass of absorbed material
 Conductimetric Sensors
 Measures electrical conductance / resistance of the solution
 Measurement has low sensitivity
 Electrical voltage is generated using sinusoidal (ac) voltage,
which helps in minimizing undesirable effects like :
i) Faradiac processes
ii) Double layer charging
iii) Concentration polarization
 Amperometric Biosensors
 High sensitivity
 Detects the electroactive species present in the biological test
samples
 Measured parameter – current
 Potentiometric Sensors
 Working principle – when voltage is applied to an electrode in
solution a current flow occurs because of electrochemical
reactions
 Measured parameter – oxidation / reduction potential of an
electrochemical run
Applications
• Food analysis
• Study of biomolecules and their interaction
• Drug development
• Crime detection
• Medical diagnosis (both clinical and laboratory use)
• Enviornmental field monitoring
• Quality control
• Industrial process control
• Detection systems for biological warefare agents
• Manufacturing of pharmaceuticals and replacement organs

More Related Content

PPTX
Biosensors
PPTX
Article 370
PDF
Article 370 Explained
PPT
Biosensors and Their Applications
DOCX
Fisheries co operative
PPTX
Biosensors: Their types
PPTX
TRANSMISI TENAGA LISTRIK
PPTX
Enzymes used in Genetic Engineering
Biosensors
Article 370
Article 370 Explained
Biosensors and Their Applications
Fisheries co operative
Biosensors: Their types
TRANSMISI TENAGA LISTRIK
Enzymes used in Genetic Engineering

What's hot (20)

PPTX
Immobilization of enzymes
PPTX
Microbial Biotransformation
PPT
Biosensors
PPTX
Fermentor
PPTX
Production of vitamin B12 using fermentation
PPTX
Production of Penicillin by Fermentation
PPTX
Biosensors and it’s application
PPTX
Biosensors working and application in pharmaceutical industry
PPTX
Column chromatography
PPTX
Affinity chromatography ppt
PPTX
AFFINITY CHROMATOGRAPHY
PPT
Column Chromatography ppt
PDF
Penicillin production fermentation
PPTX
Biosensors
PDF
Microbial transformation
PPTX
Use of microbes in industry. Production of enzymes-General consideration-Amyl...
PPTX
Production of enzymes
PPTX
Ion Exchange Chromatography ppt
PDF
Biosensor Working & Application
PPT
Enzyme immobilization and applications
Immobilization of enzymes
Microbial Biotransformation
Biosensors
Fermentor
Production of vitamin B12 using fermentation
Production of Penicillin by Fermentation
Biosensors and it’s application
Biosensors working and application in pharmaceutical industry
Column chromatography
Affinity chromatography ppt
AFFINITY CHROMATOGRAPHY
Column Chromatography ppt
Penicillin production fermentation
Biosensors
Microbial transformation
Use of microbes in industry. Production of enzymes-General consideration-Amyl...
Production of enzymes
Ion Exchange Chromatography ppt
Biosensor Working & Application
Enzyme immobilization and applications
Ad

Similar to Biosensor , its components, working and types of biosensors (20)

PPTX
Biosensor
PPTX
PPTX
Biosensors-1g348yc.pptx
PPTX
Biosensors 2022-06-26.pptx
PPTX
Biosensors-1g348yc.pptx
PPTX
Biosensor
PPTX
Biosensors
PPTX
Biosensors (structure and application)
PDF
BioSensors glucose monitoring, cholestrol
PDF
BioSensors.pdf CHOLESTROL GLUCOSE MONITORING
PPTX
intro to biosensor
PPTX
Biosensor and its Applications
PPTX
BIO SENSORS.pptx
PPTX
Nano-biosensors
PPTX
Biosensor
PPTX
PPTX
BIOSENSORS(1) by gauraw_makawana-viv.pptx
PPTX
Intro to Biosensor.pptx by taimoor khan awkum
Biosensor
Biosensors-1g348yc.pptx
Biosensors 2022-06-26.pptx
Biosensors-1g348yc.pptx
Biosensor
Biosensors
Biosensors (structure and application)
BioSensors glucose monitoring, cholestrol
BioSensors.pdf CHOLESTROL GLUCOSE MONITORING
intro to biosensor
Biosensor and its Applications
BIO SENSORS.pptx
Nano-biosensors
Biosensor
BIOSENSORS(1) by gauraw_makawana-viv.pptx
Intro to Biosensor.pptx by taimoor khan awkum
Ad

Recently uploaded (20)

PDF
Sciences of Europe No 170 (2025)
PPTX
ognitive-behavioral therapy, mindfulness-based approaches, coping skills trai...
PDF
VARICELLA VACCINATION: A POTENTIAL STRATEGY FOR PREVENTING MULTIPLE SCLEROSIS
PPTX
ANEMIA WITH LEUKOPENIA MDS 07_25.pptx htggtftgt fredrctvg
PDF
SEHH2274 Organic Chemistry Notes 1 Structure and Bonding.pdf
PDF
HPLC-PPT.docx high performance liquid chromatography
PDF
Biophysics 2.pdffffffffffffffffffffffffff
PPTX
Microbiology with diagram medical studies .pptx
PPTX
Introduction to Cardiovascular system_structure and functions-1
PPTX
EPIDURAL ANESTHESIA ANATOMY AND PHYSIOLOGY.pptx
PPTX
7. General Toxicologyfor clinical phrmacy.pptx
DOCX
Viruses (History, structure and composition, classification, Bacteriophage Re...
PDF
Unveiling a 36 billion solar mass black hole at the centre of the Cosmic Hors...
PDF
IFIT3 RNA-binding activity primores influenza A viruz infection and translati...
PPTX
Classification Systems_TAXONOMY_SCIENCE8.pptx
PPTX
2. Earth - The Living Planet earth and life
PDF
AlphaEarth Foundations and the Satellite Embedding dataset
PPTX
TOTAL hIP ARTHROPLASTY Presentation.pptx
PPTX
Comparative Structure of Integument in Vertebrates.pptx
PPTX
Protein & Amino Acid Structures Levels of protein structure (primary, seconda...
Sciences of Europe No 170 (2025)
ognitive-behavioral therapy, mindfulness-based approaches, coping skills trai...
VARICELLA VACCINATION: A POTENTIAL STRATEGY FOR PREVENTING MULTIPLE SCLEROSIS
ANEMIA WITH LEUKOPENIA MDS 07_25.pptx htggtftgt fredrctvg
SEHH2274 Organic Chemistry Notes 1 Structure and Bonding.pdf
HPLC-PPT.docx high performance liquid chromatography
Biophysics 2.pdffffffffffffffffffffffffff
Microbiology with diagram medical studies .pptx
Introduction to Cardiovascular system_structure and functions-1
EPIDURAL ANESTHESIA ANATOMY AND PHYSIOLOGY.pptx
7. General Toxicologyfor clinical phrmacy.pptx
Viruses (History, structure and composition, classification, Bacteriophage Re...
Unveiling a 36 billion solar mass black hole at the centre of the Cosmic Hors...
IFIT3 RNA-binding activity primores influenza A viruz infection and translati...
Classification Systems_TAXONOMY_SCIENCE8.pptx
2. Earth - The Living Planet earth and life
AlphaEarth Foundations and the Satellite Embedding dataset
TOTAL hIP ARTHROPLASTY Presentation.pptx
Comparative Structure of Integument in Vertebrates.pptx
Protein & Amino Acid Structures Levels of protein structure (primary, seconda...

Biosensor , its components, working and types of biosensors

  • 2. • Father of Biosensor – Professor Leland C Clark • The term ‘biosensor’ is short for “biological sensor” • Analytical device used for the detection of an analyte, that combines a biological component with a physicochemical detector. • It is a device incoporating a biological sensing element either intimately connected to or integrated within a transducer
  • 3. • Recognition based on affinity between complementary structures like:  Enzyme-substrate, antibody-antigen and receptor-hormone complex • Selectivity and specificity depend on biological recognition systems connected to a suitable transducer.
  • 4. • It converts a response into an electrical signal • It detects, records, and transmits information regarding a physiological change or process • It determines the presence and concentration of a specific substance in an test solution • Main features of biosensors are stability cost sensitivity reproducibility
  • 5. Basic principle of biosensor • Basic principle involved in three element :- o First biological recognition element which highly specific towards the biological material analytes produces o Second transducers detect and transduces signal from biological target – receptor molecule to electrical signal which is due to reaction occur o Third after transduction signal from biological to electrical signal where its amplification is necessary and takes place and read out in detector after processing the values are displayed for monitor and controlling the system
  • 8. Ist component – Biological element • The component used to bind the target molecule • Must be highly specific, stable under storage conditions and immobilized • A variety of substance may be used as bioelement in biosensor  Microorganism  Tissue, Cell, Organelle  Nucleic acid  Enzyme, Enzyme component  Receptor  Antibody  Plant proteins or lectins
  • 9. • Functions;  To interact specifically with a target compound i.e the compound to be detected  It must be capable of detecting the presence of a target compound in the test solution  The ability of a bio-element to interact with target compound (specificity) in the basis of biosensor
  • 10. 2nd component – Physiochemical Transducer • Acts as an interface, measuring the physical change that occurs with the reaction at the bioreceptor then transforming that energy into measureable electrical output
  • 11. 3rd component - Detector • Signals from the transducer are passed to a microprocessor where they are amplified and analyzed. • The data is then converted to concentration units and transferred to a display or / and data storage device
  • 13. • The block diagram of biosensor include three segments namely sensor, transducer and associated electrons. • In the first segment the sensor is a responsive biological part • Second segment is the detector part that changes the resulting signal from the contact of the analyte and for the results it displays in an accesible way • The final section comprises of an amplifier which is known as signal conditioning circuit, the display unit as well as the processor.
  • 14. Basic principle of Biosensor • The biological material is immobilized and a contact is made between the immobilized biological material and the transducer • The analyte binds to the biological material to form a bound analyte which inturn produces the electronic response that can be measured • Sometimes the analyte is converted to a product which could be associated with the release of heat, gas(oxygen), electrons, hydrogen ions. • The transducer then converts the product linked changes into electrical signals which can be amplified and measured
  • 15. Working principle of Biosensor  Analyte diffuses from the solution to the surface of the biosensor  Analyte reacts specifically and efficiently with the biological component of the biosensor  This reaction changes the physicochemical properties of the transducer surface  This leads to a change in the optical/ electronic properties of the transducer surface  The changes in the optical/ electronic properties is measured/ converted into electrical signal, which is detected
  • 16. • Usually a specific enzyme or preferred biological material is deactivated by some of the usual methods and the deactivated biological material is in near contact to the transducer • The analyte connects to the biological object to shape a clear analyte which in turn gives the electronic reaction that can be calculated • In some examples, the analyte is changed to a device which may be connected to the discharge of gas, heat, electron ions or hydrogen ions • In this the transducer can alter the device linked converts into electrical signals which can be changed and calculated
  • 18. How does they work…?? • Basically it involve the quantitative analysis of various substances by converting their biological actions into measurable signals • Generally the performance of the biosensors is mostly dependent on the specificity and sensitivity of the biological reaction, besides the stability of the enzyme
  • 19. Ideal Biosensor 1. The output signal must be relevant to measurement enviornment 2. The functional surface must be compatible with the transducer 3. High specificity and sensitivity (low interference) 4. Sufficient sensitivity and resolution 5. Surface accuracy and repeatability 6. Sufficient speed of response 7. Sufficient dynamic range 8. Intensivity to enviornmental interference or their effects must be compensated
  • 20. Basic characteristics of Biosensor 1. LINEARITY – linearity of the sensor should be high for the detection of high substrate concentration 2. SENSITIVITY – Value of the electrode response per substrate concentration 3. SELECTIVITY – Chemicals interference must be minimised for obtaining the correct result 4. RESPONSE TIME – Time necessary for having 95% of the response
  • 21. Typical Sensing Techniques  Fluorescence  DNA Microarray  SPR (Surface Plasma Resistance)  Impedance Spectroscopy  SPM (Scanning Probe Microscopy)  QCM (Quartz Crystal Microbalance)  SERS (Surface Enhanced Raman Spectroscopy)
  • 22. Types  Calorimetric / Thermal Detection Biosensors  Optical Biosensors  Resonant Biosensors  Piezoelectric Biosensors  Ion Sensitive Biosensors  Electrochemical Biosensors * Conductimetric Sensors * Amperometric Sensors * Potentiometric Sensors
  • 23.  Calorimetric / Thermal Detection Biosensors  Uses Absorption / Production of heat  Total heat produced / absorbed is α Molar Enthalpy / Total No. of molecules in the run  Tem. Measured by Enzyme Thermistors Advantages • No need of frequent recalibration • Intensitive to the optical and electrochemical properties of the sample Uses • Detection of : (1) Pesticides (2) Pathogenic bacteria
  • 24.  Ion Sensitive Biosensors  Surface electrical potential changes when the ion and semiconductor interact  Measures the change in potential  Uses  Detection of pH  Electrochemical Biosensors  Many chemical runs produce or consume ions or electrons causing some change in the electrical properties of the solution that can be sensed out and used as a measuring parameter  Uses  Detection of :- (1) hybridized DNA (2) DNA binding drugs (3) glucose concentration
  • 25.  Optical Biosensors  Colorimetric for colour – Measure change in light adsorption  Photometric for light intensity – Detects the photon input  Resonant Biosensors • An Acoustic Wave Transducer is coupled with bioelement • Measures the change in Resonant Frequency  Piezoelectric Biosensors • Uses gold – To detect specific angle at which electron waves are emitted when the substance is exposed to laser light/ crystals like quartz, which vibrates under the influence of an electric field • Change in frequency α Mass of absorbed material
  • 26.  Conductimetric Sensors  Measures electrical conductance / resistance of the solution  Measurement has low sensitivity  Electrical voltage is generated using sinusoidal (ac) voltage, which helps in minimizing undesirable effects like : i) Faradiac processes ii) Double layer charging iii) Concentration polarization  Amperometric Biosensors  High sensitivity  Detects the electroactive species present in the biological test samples  Measured parameter – current
  • 27.  Potentiometric Sensors  Working principle – when voltage is applied to an electrode in solution a current flow occurs because of electrochemical reactions  Measured parameter – oxidation / reduction potential of an electrochemical run
  • 28. Applications • Food analysis • Study of biomolecules and their interaction • Drug development • Crime detection • Medical diagnosis (both clinical and laboratory use) • Enviornmental field monitoring • Quality control • Industrial process control • Detection systems for biological warefare agents • Manufacturing of pharmaceuticals and replacement organs