SPECIFICATIONS
ORDERING INFORMATION
Features
› Automatic electronic current limiting feature
› Voltage transient protection on all power and signal input/
output lines provides unconditional protection from power
surges and other voltage transient events.
› (14) Fourteen 1-inch rack slots available
› All modules located within the chassis rack are hot-
swappable
› Lifetime Warranty
The design approach employed by ComNet™
for equipment mounted within
the card cage rack unit (C1-CH) with modular power supply (C1PS), provides for
the elimination of a single-point failure in the event of a major fault within any
module located within the chassis rack. This is accomplished through the use of
automatic electronic current limiting within each rack-mountable module, rather
than providing the current limiting within the power supply unit which supports
the power requirements for equipment located within the rack. In nearly all
competing designs,a major fault within a module, located within the chassis rack,
results in the power supply unit going into a current limiting condition, and as a
result, all of the modules within the rack shut down. The rack design employed
by ComNet eliminates this possibility, as only the faulty module shuts down,
and the operation of the other modules within the rack continue unimpaired.
This automatic current limiting feature is also self-resetting, should the fault or
overload be of a temporary or intermittent condition. Furthermore, all modules
located within the chassis rack are hot-swappable, so that it is not necessary to
power-down the rack when removing or replacing modules.
C1
Rack Mount Card Cage With Power Supply
Electrical
	 Input Voltage	 90-264 VAC @ 70 W Maximum
	 Output Voltage	 9 VDC +/- 5% @ 6.5 Amps @ 75˚C
Fusing			 1.25 A slow blow (rack power supply)
Plug-in modules individually electronically fused.
Each power supply unit is individually fused.
Power Indicator		 Red LED	
AC Line Cord		 Detachable, IEC-connected. Allows easy field
replacement or exchange for various worldwide AC
power plug configurations.
Mechanical
	 Size (L × W × H)
	 Rack Mount:	19.0 × 7.5 × 6.9 in. (48.2 × 19 × 17.5 cm)
	 Rack Slots:		 (14) 1-inch slots available
	 Shipping Weight:	 5 lbs./2.15 kg
Environmental
	MTBF		100,000 hours
	 Operating Temp	 -40˚ C to +75˚ C
	 Storage Temp	 -40˚ C to +85˚ C
	 Heat Generation	 240 BTU
AGENCY COMPLIANCE*
*Power Supply Only
In a continuing effort to improve and advance technology, product specifications are subject to change without notice.
Part Number Description
C1-US 19” Rack (US AC Power Cord)
C1-EU 19” Rack (EU  UK Power Cord)
C1-IN 19” Rack (US, EU, UK  AU Power Cord)
C1-CH 19” Rack (no power supply)
C1PS
Spare 90-264 VAC Input Power Supply
(order power cords separately)
Included Accessories 90-264 VAC Input (includes power supply and power cord)
Included with C1-US, C1-EU and C1-IN only
Options C1-BP – Blank Panel (1”)
C1-BP2 – Blank Panel (2”)
C1-BP3 – Blank Panel (3”)
C1-SA – South African Power Cord
C1-AU – Australian Power Cord

More Related Content

PDF
ComNet C1PS Data Sheet
PDF
Comnet C2US Data Sheet
PDF
Riello vdc-xeb-flywheel-enery-storage-systems
PDF
Nidec asi electric power solutions for ship to shore connection
PDF
CG (Crompton Greaves) Alternators
PDF
Growatt 50000 80000
PDF
MGJ3andMGJ6Presentationversion2c.PDF
PDF
ComNet CNGE8US Data Sheet
ComNet C1PS Data Sheet
Comnet C2US Data Sheet
Riello vdc-xeb-flywheel-enery-storage-systems
Nidec asi electric power solutions for ship to shore connection
CG (Crompton Greaves) Alternators
Growatt 50000 80000
MGJ3andMGJ6Presentationversion2c.PDF
ComNet CNGE8US Data Sheet

What's hot (17)

PDF
Ricardo DC-DC Converter Presentation for NMI
PDF
9E_Datasheet-RevB-LD
PDF
Nidec asi silcovert tn
PPTX
Staco Energy: Corporate Overview
PDF
SYSTEMS SUNLIGHT S.A. | Global Solutions for Renewable Energy Storage
PDF
Zeversolar datasheets 3-phase_inverters
PDF
Tube Data Sheet
PPTX
4 Wired Networks Whiteboard 2016
PDF
Misura scariche parziali - Sensori MC Monitoring PDC24-1000
PDF
Orissa wicomm-product presentation
PDF
ComNet FVTDR101B Data Sheet
PDF
Introduction to the Amito Reading data centre 2020
PDF
Applimotion ho series_motors_datasheet
PDF
Impulse tester 7700 7710_7720
PPTX
3 Great Networks & Switches Whiteboard 2016
PDF
NetSure 4015 30kW 400V DC System Datasheet
PDF
Rsf electronik incremental_rotary_encoder_dg151_specsheet
Ricardo DC-DC Converter Presentation for NMI
9E_Datasheet-RevB-LD
Nidec asi silcovert tn
Staco Energy: Corporate Overview
SYSTEMS SUNLIGHT S.A. | Global Solutions for Renewable Energy Storage
Zeversolar datasheets 3-phase_inverters
Tube Data Sheet
4 Wired Networks Whiteboard 2016
Misura scariche parziali - Sensori MC Monitoring PDC24-1000
Orissa wicomm-product presentation
ComNet FVTDR101B Data Sheet
Introduction to the Amito Reading data centre 2020
Applimotion ho series_motors_datasheet
Impulse tester 7700 7710_7720
3 Great Networks & Switches Whiteboard 2016
NetSure 4015 30kW 400V DC System Datasheet
Rsf electronik incremental_rotary_encoder_dg151_specsheet
Ad

Viewers also liked (18)

DOCX
En equipos
PPTX
Dimitris - Stone...Build..by..Roses..
PDF
Star of the Month
PDF
ComNet NW7 Data Sheet
PPTX
Sewa laptop
PDF
ComNet RMB1 Data Sheet
DOCX
Indicador
PDF
wolves and Jack Frost, oooh.
DOCX
Compuadora pc
PDF
Nota prensa "Melo Bakale", LP "Corazón Gigante" 2015
PDF
Hufrehe
PDF
KELSEY_HILLERUD_SPRING15
PDF
Qi Wang's Transcript for undergradute
PDF
Isolant mince
DOC
Media treatment
PDF
Comelit SK9050GR Data Sheet
PDF
Project manager germany
En equipos
Dimitris - Stone...Build..by..Roses..
Star of the Month
ComNet NW7 Data Sheet
Sewa laptop
ComNet RMB1 Data Sheet
Indicador
wolves and Jack Frost, oooh.
Compuadora pc
Nota prensa "Melo Bakale", LP "Corazón Gigante" 2015
Hufrehe
KELSEY_HILLERUD_SPRING15
Qi Wang's Transcript for undergradute
Isolant mince
Media treatment
Comelit SK9050GR Data Sheet
Project manager germany
Ad

Similar to ComNet C1-US Data Sheet (20)

PDF
ComNet C1PS Data Sheet
PDF
ComNet C2US Data Sheet
PDF
ComNet C3US Data Sheet
PDF
Comnet C3US Data Sheet
PDF
ComNet C3US User Manual
PPTX
Argus 012-012-20
PDF
神州数码 Jason pan future_clouddatacenterv2
PDF
Customizable High Density Data Center Enclosures
PDF
Make india = make in india presentation by cs electric (2 files merged)
PPTX
Efore DC backup SYSTEM, Master Portfolio 2016, uninterruptible power supply
PDF
Presentation gamatronic
PDF
power 6210.pdf
PDF
Vertx v300 ds_en
PDF
GEC GEM80 Series
PDF
RUGGEDCOM RPS1300 accessories
PDF
RK Engineering Load Break Switches.pdf
PDF
Industrial Automation Company In India | Electrical Automation Company in Ind...
PDF
Vertx v1000 ds_en
PDF
3RU AOS03 Catv optical transmission platform
PDF
Catalog cs switch disconnector_fuse_units_dienhathe.vn
ComNet C1PS Data Sheet
ComNet C2US Data Sheet
ComNet C3US Data Sheet
Comnet C3US Data Sheet
ComNet C3US User Manual
Argus 012-012-20
神州数码 Jason pan future_clouddatacenterv2
Customizable High Density Data Center Enclosures
Make india = make in india presentation by cs electric (2 files merged)
Efore DC backup SYSTEM, Master Portfolio 2016, uninterruptible power supply
Presentation gamatronic
power 6210.pdf
Vertx v300 ds_en
GEC GEM80 Series
RUGGEDCOM RPS1300 accessories
RK Engineering Load Break Switches.pdf
Industrial Automation Company In India | Electrical Automation Company in Ind...
Vertx v1000 ds_en
3RU AOS03 Catv optical transmission platform
Catalog cs switch disconnector_fuse_units_dienhathe.vn

More from JMAC Supply (20)

PDF
Bosch ALTV244UL Data Sheet
PDF
Bosch AL1002WAL Data Sheet
PDF
Bosch AIM-AEC21-CVT Data Sheet
PDF
Bosch AI1 Data Sheet
PDF
Bosch AH-24WP-R Data Sheet
PDF
Bosch AEC-8I8O-EXT Data Sheet
PDF
Bosch AE774 Data Sheet
PDF
Bosch AE203R Data Sheet
PDF
Bosch AE101 Data Sheet
PDF
Bosch AE4 Data Sheet
PDF
Bosch AE1 Data Sheet
PDF
Bosch ACD-IC16K37-50 Data Sheet
PDF
Bosch ACD-IC2K37-50 Data Sheet
PDF
Bosch ACA-IC2K26-10 Data Sheet
PDF
Bosch 9208B Data Sheet
PDF
Bosch 7110XC Data Sheet
PDF
Samsung Techwin SNB-1000 Data Sheet
PDF
Samsung Techwin SMT-4031 Data Sheet
PDF
Samsung Techwin SMT-4023 Data Sheet
PDF
Samsung Techwin SMT-3232 Data Sheet
Bosch ALTV244UL Data Sheet
Bosch AL1002WAL Data Sheet
Bosch AIM-AEC21-CVT Data Sheet
Bosch AI1 Data Sheet
Bosch AH-24WP-R Data Sheet
Bosch AEC-8I8O-EXT Data Sheet
Bosch AE774 Data Sheet
Bosch AE203R Data Sheet
Bosch AE101 Data Sheet
Bosch AE4 Data Sheet
Bosch AE1 Data Sheet
Bosch ACD-IC16K37-50 Data Sheet
Bosch ACD-IC2K37-50 Data Sheet
Bosch ACA-IC2K26-10 Data Sheet
Bosch 9208B Data Sheet
Bosch 7110XC Data Sheet
Samsung Techwin SNB-1000 Data Sheet
Samsung Techwin SMT-4031 Data Sheet
Samsung Techwin SMT-4023 Data Sheet
Samsung Techwin SMT-3232 Data Sheet

Recently uploaded (20)

DOCX
search engine optimization ppt fir known well about this
PPTX
Tartificialntelligence_presentation.pptx
PPTX
Benefits of Physical activity for teenagers.pptx
PDF
Developing a website for English-speaking practice to English as a foreign la...
PPTX
Final SEM Unit 1 for mit wpu at pune .pptx
PDF
Microsoft Solutions Partner Drive Digital Transformation with D365.pdf
PDF
WOOl fibre morphology and structure.pdf for textiles
PDF
sustainability-14-14877-v2.pddhzftheheeeee
PPT
Geologic Time for studying geology for geologist
PDF
A contest of sentiment analysis: k-nearest neighbor versus neural network
PPTX
Chapter 5: Probability Theory and Statistics
PDF
Unlock new opportunities with location data.pdf
PDF
DP Operators-handbook-extract for the Mautical Institute
PPTX
MicrosoftCybserSecurityReferenceArchitecture-April-2025.pptx
PPT
What is a Computer? Input Devices /output devices
PDF
A novel scalable deep ensemble learning framework for big data classification...
PPTX
O2C Customer Invoices to Receipt V15A.pptx
PDF
Getting Started with Data Integration: FME Form 101
PDF
CloudStack 4.21: First Look Webinar slides
PDF
Architecture types and enterprise applications.pdf
search engine optimization ppt fir known well about this
Tartificialntelligence_presentation.pptx
Benefits of Physical activity for teenagers.pptx
Developing a website for English-speaking practice to English as a foreign la...
Final SEM Unit 1 for mit wpu at pune .pptx
Microsoft Solutions Partner Drive Digital Transformation with D365.pdf
WOOl fibre morphology and structure.pdf for textiles
sustainability-14-14877-v2.pddhzftheheeeee
Geologic Time for studying geology for geologist
A contest of sentiment analysis: k-nearest neighbor versus neural network
Chapter 5: Probability Theory and Statistics
Unlock new opportunities with location data.pdf
DP Operators-handbook-extract for the Mautical Institute
MicrosoftCybserSecurityReferenceArchitecture-April-2025.pptx
What is a Computer? Input Devices /output devices
A novel scalable deep ensemble learning framework for big data classification...
O2C Customer Invoices to Receipt V15A.pptx
Getting Started with Data Integration: FME Form 101
CloudStack 4.21: First Look Webinar slides
Architecture types and enterprise applications.pdf

ComNet C1-US Data Sheet

  • 1. 3 CORPORATE DRIVE | DANBURY, CONNECTICUT 06810 | USA | T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET 8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE | T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET SPECIFICATIONS ORDERING INFORMATION Features › Automatic electronic current limiting feature › Voltage transient protection on all power and signal input/ output lines provides unconditional protection from power surges and other voltage transient events. › (14) Fourteen 1-inch rack slots available › All modules located within the chassis rack are hot- swappable › Lifetime Warranty The design approach employed by ComNet™ for equipment mounted within the card cage rack unit (C1-CH) with modular power supply (C1PS), provides for the elimination of a single-point failure in the event of a major fault within any module located within the chassis rack. This is accomplished through the use of automatic electronic current limiting within each rack-mountable module, rather than providing the current limiting within the power supply unit which supports the power requirements for equipment located within the rack. In nearly all competing designs,a major fault within a module, located within the chassis rack, results in the power supply unit going into a current limiting condition, and as a result, all of the modules within the rack shut down. The rack design employed by ComNet eliminates this possibility, as only the faulty module shuts down, and the operation of the other modules within the rack continue unimpaired. This automatic current limiting feature is also self-resetting, should the fault or overload be of a temporary or intermittent condition. Furthermore, all modules located within the chassis rack are hot-swappable, so that it is not necessary to power-down the rack when removing or replacing modules. C1 Rack Mount Card Cage With Power Supply Electrical Input Voltage 90-264 VAC @ 70 W Maximum Output Voltage 9 VDC +/- 5% @ 6.5 Amps @ 75˚C Fusing 1.25 A slow blow (rack power supply) Plug-in modules individually electronically fused. Each power supply unit is individually fused. Power Indicator Red LED AC Line Cord Detachable, IEC-connected. Allows easy field replacement or exchange for various worldwide AC power plug configurations. Mechanical Size (L × W × H) Rack Mount: 19.0 × 7.5 × 6.9 in. (48.2 × 19 × 17.5 cm) Rack Slots: (14) 1-inch slots available Shipping Weight: 5 lbs./2.15 kg Environmental MTBF 100,000 hours Operating Temp -40˚ C to +75˚ C Storage Temp -40˚ C to +85˚ C Heat Generation 240 BTU AGENCY COMPLIANCE* *Power Supply Only In a continuing effort to improve and advance technology, product specifications are subject to change without notice. Part Number Description C1-US 19” Rack (US AC Power Cord) C1-EU 19” Rack (EU UK Power Cord) C1-IN 19” Rack (US, EU, UK AU Power Cord) C1-CH 19” Rack (no power supply) C1PS Spare 90-264 VAC Input Power Supply (order power cords separately) Included Accessories 90-264 VAC Input (includes power supply and power cord) Included with C1-US, C1-EU and C1-IN only Options C1-BP – Blank Panel (1”) C1-BP2 – Blank Panel (2”) C1-BP3 – Blank Panel (3”) C1-SA – South African Power Cord C1-AU – Australian Power Cord