SlideShare a Scribd company logo
Communications Systems | LBB 1946/00 Plena Six-zone Call Station




LBB 1946/00 Plena Six-zone Call Station
                                                                 ▶ Stylish six-zone call station, intended for
                                                                   LBB 1925/10 system pre-amplifier
                                                                 ▶ Unidirectional condenser microphone on flexible
                                                                   stem
                                                                 ▶ Six zone selection keys, all-call key, and momentary
                                                                   PTT-key for calls
                                                                 ▶ Selectable gain, speech filter, and limiter for
                                                                   improved intelligibility
                                                                 ▶ Selectable priority levels and different pre and post-
                                                                   call chimes
                                                                 ▶ LED indications for zone selection, system activity,
                                                                   and call station status




The Plena Six-zone Call Station is a stylish, high-quality       •   Six zone selection keys
call station with a stable metal base design, a flexible         •   Six zone selection LEDs
microphone stem, and a unidirectional condenser                  •   All-call key
microphone. It can make calls to selected zones (one to
                                                                 •   All-call status LED
                                                                 •   Eight DIP switches
six and all-call) in a public address system built around
                                                                 Interconnections
the LBB 1925/10 system pre-amplifier. In addition to
tabletop use, the special design enables the unit to be
                                                                 • Cable with DIN connector
neatly flush-mounted in desktops.

                                                                 Certifications and Approvals

Functions
                                                                 Region           Certification
This call station features selectable gain, a selectable
                                                                 Europe            CE             Declaration of Conformity
speech filter, and a limiter for improved intelligibility. The
call station has a balanced line level output, making it         Safety                     acc. to EN 60065
possible to position it up to 100 m away from the                Immunity                   acc. to EN 55103-2
LBB 1925/10, using extension cables.
                                                                 Emission                   acc. to EN 55103-1
Dipswitches on the bottom of the call station configure
different pre and post-call chimes, as well as the priority
level. LEDs on the call station indicate selected zones, and     Parts Included
an additional, two-color LED gives visible feedback on the
active state of the microphone and the system. Green             Quantity Component
indicates microphone on or chime active (flashing LED);          1          LBB 1946/00 Plena Six-zone Call Station
amber indicates that the system is occupied by a source          1          5 m cable terminated with a lockable 8-pin DIN connector
with a higher priority or operation error (flashing LED).
                                                                 1          Loop through 8-pin DIN socket to add an additional call station
Controls and indicators                                                     LBB 1941/00 or LBB 1946/00
• PTT-key
• PTT status LED


                                                                                                          www.boschsecurity.com
2 | LBB 1946/00 Plena Six-zone Call Station



  Technical Specifications
  Electrical

  Power Supply
  Voltage Range                             18 to 24 V (24 V supplied by
                                            LBB 1925/10)
  Current consumption                       <30 mA
  Performance
  Nominal sensitivity                       85 dB SPL (gain preset 0 dB)
  Nominal output level                      700 mV
  Maximum input sound level                 110 dB SPL
  Gain preset                               +6 / 0 / -15 dB
  Limiter threshold                         2V
  Compression ratio limiter                 1:20
  Distortion                                <0.6% (maximum input)
  Input noise level (equiv.)                25 dB SPLA
  Frequency response                        100 Hz to 16 kHz
  Speech filter                             -3dB @ 315 Hz, high-pass, 6 dB/oct
  Output impedance                          200 ohm
  Selections
  Chimes                                    18 different combinations
  Priorities                                2 different priorities
  Mechanical

  Base dimensions (H x W x D)               40 x 100 x 235 mm (1.57 x 3.97 x 9.25
                                            in)
  Weight                                    Approx. 1 kg (2.2 lb)
  Color                                     Charcoal with silver
  Stem length with mic                      390 mm (15.35 in)
  Cable length                              5 m (16.4 ft)
  Environmental

  Operating temperature                     -10 ºC to +55 ºC (14 ºF to +131 ºF)
  Storage temperature                       -40 ºC to +70 ºC (-40 ºF to +158 ºF)
  Relative humidity                         <95%



  Ordering Information
    LBB 1946/00 Plena Six-zone Call Station                          LBB1946/00
    metal base design, a flexible microphone
    stem, and a unidirectional condenser micro-
    phone. It can make calls to selected zones
    (one to six and all-call).




Americas:                                Europe, Middle East, Africa:         Asia-Pacific:                   Represented by
Bosch Communications Systems             Bosch Security Systems B.V.          Robert Bosch (SEA) Pte Ltd
12000 Portland Avenue South              P.O. Box 80002                       11 Bishan Street 21
Burnsville, Minnesota 55337, USA         5600 JB Eindhoven, The Netherlands   Singapore 573943
Phone: +1-800-392-3497                   Phone: + 31 40 2577 284              Phone: +65 6571 2600
Fax: +1-800-955-6831                     Fax: +31 40 2577 330                 Fax: +65 6571 2698
audiosupport@us.bosch.com                emea.securitysystems@bosch.com       apr.securitysystems@bosch.com
www.boschsecurity.com                    www.boschsecurity.com                www.boschsecurity.com



© Bosch Security Systems Inc. 011 | Data subject to change without notice
T866494731 | Cur: en-US, V25, 27 Jan 2011

More Related Content

PDF
Data sheet en_us_1890384523
PDF
Lbb194100
PDF
Data sheet en_us_1893111307
PDF
Data sheet en_us_1886490251
PDF
Data sheet en_us_1889481483
PDF
Data sheet en_us_1893651851
PDF
Data sheet en_us_1893923979
PDF
Data sheet en_us_1882681611
Data sheet en_us_1890384523
Lbb194100
Data sheet en_us_1893111307
Data sheet en_us_1886490251
Data sheet en_us_1889481483
Data sheet en_us_1893651851
Data sheet en_us_1893923979
Data sheet en_us_1882681611

What's hot (17)

PDF
Data sheet en_us_1881362443
PDF
Data sheet en_us_1889254027
PDF
Data sheet en_us_1889715339
PDF
Data sheet en_us_1886736267
PDF
Data sheet en_us_1890629515
PDF
Data sheet en_us_7912980875
PDF
Data sheet en_us_1882491531
PDF
Data sheet en_us_1870662155
PDF
Soundcraft Epm Mpm
PDF
Data sheet en_us_7912958219
PDF
Data sheet en_us_1871477643
PDF
Sound Devices MixPre
PDF
Data sheet en_us_1891241867
PDF
Data sheet en_us_8337546379
PDF
Data sheet en_us_1882003851_2
PDF
Data sheet en_us_1868002443
PDF
Data sheet en_us_1870174347
Data sheet en_us_1881362443
Data sheet en_us_1889254027
Data sheet en_us_1889715339
Data sheet en_us_1886736267
Data sheet en_us_1890629515
Data sheet en_us_7912980875
Data sheet en_us_1882491531
Data sheet en_us_1870662155
Soundcraft Epm Mpm
Data sheet en_us_7912958219
Data sheet en_us_1871477643
Sound Devices MixPre
Data sheet en_us_1891241867
Data sheet en_us_8337546379
Data sheet en_us_1882003851_2
Data sheet en_us_1868002443
Data sheet en_us_1870174347
Ad

Similar to Data sheet en_us_1888281611 (20)

PDF
Data sheet en_us_1872712715
PDF
Data sheet en_us_1882870923
PDF
Data sheet en_us_1870943371
PDF
Data sheet en_us_1883412235
PDF
Data sheet en_us_1872223499
PDF
Data sheet en_us_1888512395
PDF
Data sheet en_us_1871726475
PDF
Data sheet en_us_1871726475
PDF
Data sheet en_us_7912962443
PDF
Data sheet en_us_1930931083
PDF
Data sheet en_us_1926910475
PDF
Data sheet en_us_1889956491
PDF
Data sheet en_us_1890629515
PDF
Data sheet en_us_1928736779
PDF
Data sheet en_us_1854019723
PDF
PDF
Data sheet en_us_1875886859
PDF
Data sheet en_us_1909181707
PDF
Data sheet en_us_1909181707
PDF
Data sheet en_us_1909181707
Data sheet en_us_1872712715
Data sheet en_us_1882870923
Data sheet en_us_1870943371
Data sheet en_us_1883412235
Data sheet en_us_1872223499
Data sheet en_us_1888512395
Data sheet en_us_1871726475
Data sheet en_us_1871726475
Data sheet en_us_7912962443
Data sheet en_us_1930931083
Data sheet en_us_1926910475
Data sheet en_us_1889956491
Data sheet en_us_1890629515
Data sheet en_us_1928736779
Data sheet en_us_1854019723
Data sheet en_us_1875886859
Data sheet en_us_1909181707
Data sheet en_us_1909181707
Data sheet en_us_1909181707
Ad

More from amthanhbosch (20)

PDF
Data sheet en_us_1896962059
PDF
Data sheet en_us_1882003851_2
PDF
Data sheet en_us_1853732619
PDF
Data sheet en_us_1858220555
PDF
Data sheet en_us_1853504907
PDF
Data sheet en_us_1940296331
PDF
Data sheet en_us_1942653835
PDF
Data sheet en_us_1942653835
PDF
Data sheet en_us_1940296331
PDF
Data sheet en_us_1861800331
PDF
Data sheet en_us_1860884875
PDF
Data sheet en_us_1874020363
PDF
Data sheet en_us_1874912523
PDF
Bosch 2553 pa
PDF
Data sheet en_us_1871224715
PDF
Data sheet en_us_1871977867
PDF
Data sheet en_us_1870416907
PDF
Data sheet en_us_1879347467
PDF
Data sheet en_us_1875147915
PDF
Data sheet en_us_1875638795
Data sheet en_us_1896962059
Data sheet en_us_1882003851_2
Data sheet en_us_1853732619
Data sheet en_us_1858220555
Data sheet en_us_1853504907
Data sheet en_us_1940296331
Data sheet en_us_1942653835
Data sheet en_us_1942653835
Data sheet en_us_1940296331
Data sheet en_us_1861800331
Data sheet en_us_1860884875
Data sheet en_us_1874020363
Data sheet en_us_1874912523
Bosch 2553 pa
Data sheet en_us_1871224715
Data sheet en_us_1871977867
Data sheet en_us_1870416907
Data sheet en_us_1879347467
Data sheet en_us_1875147915
Data sheet en_us_1875638795

Data sheet en_us_1888281611

  • 1. Communications Systems | LBB 1946/00 Plena Six-zone Call Station LBB 1946/00 Plena Six-zone Call Station ▶ Stylish six-zone call station, intended for LBB 1925/10 system pre-amplifier ▶ Unidirectional condenser microphone on flexible stem ▶ Six zone selection keys, all-call key, and momentary PTT-key for calls ▶ Selectable gain, speech filter, and limiter for improved intelligibility ▶ Selectable priority levels and different pre and post- call chimes ▶ LED indications for zone selection, system activity, and call station status The Plena Six-zone Call Station is a stylish, high-quality • Six zone selection keys call station with a stable metal base design, a flexible • Six zone selection LEDs microphone stem, and a unidirectional condenser • All-call key microphone. It can make calls to selected zones (one to • All-call status LED • Eight DIP switches six and all-call) in a public address system built around Interconnections the LBB 1925/10 system pre-amplifier. In addition to tabletop use, the special design enables the unit to be • Cable with DIN connector neatly flush-mounted in desktops. Certifications and Approvals Functions Region Certification This call station features selectable gain, a selectable Europe CE Declaration of Conformity speech filter, and a limiter for improved intelligibility. The call station has a balanced line level output, making it Safety acc. to EN 60065 possible to position it up to 100 m away from the Immunity acc. to EN 55103-2 LBB 1925/10, using extension cables. Emission acc. to EN 55103-1 Dipswitches on the bottom of the call station configure different pre and post-call chimes, as well as the priority level. LEDs on the call station indicate selected zones, and Parts Included an additional, two-color LED gives visible feedback on the active state of the microphone and the system. Green Quantity Component indicates microphone on or chime active (flashing LED); 1 LBB 1946/00 Plena Six-zone Call Station amber indicates that the system is occupied by a source 1 5 m cable terminated with a lockable 8-pin DIN connector with a higher priority or operation error (flashing LED). 1 Loop through 8-pin DIN socket to add an additional call station Controls and indicators LBB 1941/00 or LBB 1946/00 • PTT-key • PTT status LED www.boschsecurity.com
  • 2. 2 | LBB 1946/00 Plena Six-zone Call Station Technical Specifications Electrical Power Supply Voltage Range 18 to 24 V (24 V supplied by LBB 1925/10) Current consumption <30 mA Performance Nominal sensitivity 85 dB SPL (gain preset 0 dB) Nominal output level 700 mV Maximum input sound level 110 dB SPL Gain preset +6 / 0 / -15 dB Limiter threshold 2V Compression ratio limiter 1:20 Distortion <0.6% (maximum input) Input noise level (equiv.) 25 dB SPLA Frequency response 100 Hz to 16 kHz Speech filter -3dB @ 315 Hz, high-pass, 6 dB/oct Output impedance 200 ohm Selections Chimes 18 different combinations Priorities 2 different priorities Mechanical Base dimensions (H x W x D) 40 x 100 x 235 mm (1.57 x 3.97 x 9.25 in) Weight Approx. 1 kg (2.2 lb) Color Charcoal with silver Stem length with mic 390 mm (15.35 in) Cable length 5 m (16.4 ft) Environmental Operating temperature -10 ºC to +55 ºC (14 ºF to +131 ºF) Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF) Relative humidity <95% Ordering Information LBB 1946/00 Plena Six-zone Call Station LBB1946/00 metal base design, a flexible microphone stem, and a unidirectional condenser micro- phone. It can make calls to selected zones (one to six and all-call). Americas: Europe, Middle East, Africa: Asia-Pacific: Represented by Bosch Communications Systems Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd 12000 Portland Avenue South P.O. Box 80002 11 Bishan Street 21 Burnsville, Minnesota 55337, USA 5600 JB Eindhoven, The Netherlands Singapore 573943 Phone: +1-800-392-3497 Phone: + 31 40 2577 284 Phone: +65 6571 2600 Fax: +1-800-955-6831 Fax: +31 40 2577 330 Fax: +65 6571 2698 audiosupport@us.bosch.com emea.securitysystems@bosch.com apr.securitysystems@bosch.com www.boschsecurity.com www.boschsecurity.com www.boschsecurity.com © Bosch Security Systems Inc. 011 | Data subject to change without notice T866494731 | Cur: en-US, V25, 27 Jan 2011