ORACLE DATA SHEET




                                            SUN RACK II
KEY BENEFITS                                Th                                                                               ease  of  use,  
OPTIMIZE YOUR SPACE
                                            flexibility,  and  optimal  application  of  your  limited  space  to  bring  better  ROI  
 Optimization for vertical density
                                            and  utilization  to  your  IT  infrastructure.  Offering  42U  capacity,  these  
 Choice of 1,058 mm or 1,200 mm depth
                                            innovative,  industry-­standard  19-­inch  racks  pack  a  maximum  number  of  
 Highest-capacity power in two of the
 smallest footprints available
                                            components,  cables,  and  accessories  into  two  fl
 Easy-to-install, compact PDUs with
                                            providing  the  power  infrastructure  you  need.  
 phase-current metering capabilities

 Ease of use and maintenance in robust
 and safe designs capable of shipping
 fully loaded

 Consistency with the latest Oracle rack-
 mount products for a uniform look in the
 data center




                                            Designed for vertical density, the Sun Rack II provides a minimized footprint for
                                            optimization of data center space.


                                            Sun Rack II Product Overview
                                            The Sun Rack II product line is well suited to a variety of data center environments. This
                                            robust and cost-effective family of racks is optimized for vertical density and provides a
                                            uniform appearance in your data center when installed with the latest Oracle servers and
                                            storage products. The racks can be purchased with a strong shipping pallet for transport when
                                            fully integrated with components. They offer an assortment of zero-RU, easily installed,
                                            metered power distribution units (PDUs) for maximal rack power capacity in a minimal
                                            footprint. In addition, they have been optimized for cooling, and both the front and rear doors
                                            have 80 percent perforations that provide a high level of airflow through the rack.



                                            Sun Rack II Features
                                            The Sun Rack II includes the following features:

                                                    42U height, choice of 1,058 mm or 1,200 mm depth, and 600 mm width, with
                                                    industry-standard 19-inch adjustable square-hole RETMA rails to accommodate most
                                                    Oracle and third party rack-mountable IT equipment

                                                    Selection of zero-RU PDU options with various input and output connectors,
                                                    providing the highest density in the lowest profile
ORACLE DATA SHEET




            80 percent door perforations, enabling a high level of airflow through the cabinet

            Extruded aluminum frame and reduced rack height, making the rack relatively light
            and easy to handle and enabling it to be safely rolled through most standard doorways

            2,215 lb. (1,005 kg) maximum load a rugged platform users can populate with more
            components; available with enterprise packaging for safe shipment



    Sun Rack II Specifications
     PDUs
       A selection of 8 PDUs, from 10 kVA to 37 kVA, is available in single- and three-phase,
       low- and high-voltage versions, with 14 to 45 C13 and two to 9 C19 outlets available
       on a single PDU.
        Designed for quick and easy installation, each easy-to-mount PDU takes up zero RU,
       enabling high vertical density and providing unobstructed access to rear FRUs and
       accessories.
       The flexibility to add or change PDUs based on new data center wiring means that the
       rack can be upgraded with higher-density PDUs.
       Rack-level power metering capability* with an LCD PDU display screen and a remote
       network connection and the ability to set threshold and alarm levels prevents
       overloaded circuits by providing a visible warning when the current draw is close to
       the maximum amperage draw of the PDU strip


     Stabilization Features
       Two foldaway anti-tilt bars inside the rack to ensure balance and prevent tipping
       during equipment service from the front
       Four leveling feet that can be lowered to the floor
       Four floor-mounting brackets for extra safety
     Dimensions
     Model 1242                                                 Model 1042
     Height: 199.8cm (78.7 in.)                                 Height: 199.8cm (78.7 in.)
     Width: 60cm (23.6 in.)                                     Width: 60cm (23.6 in.)
     Depth: 120cm (47.2 in.)                                    Depth: 105.8cm (41.66 in.)
     Weight: 150.6 kg (332 lbs.) empty                          Weight: 123.4 kg (272 lbs.)
     Models 1242 and 1042
     Usable rack units                                          42
                                                                685.8mm (27 in.) adjustable from
     Depth between front and rear RETMA rails
                                                                61.5mm(24.2 in.) to 825.8mm (32.4 in.)
     Maximum dynamic load**                                     1,005 kg (2,215 lbs.)
     Maintenance access requirement from rear                   91.4cm (36 in.)
     Maintenance access requirement from top                    91.4cm (36 in.)

     ** Racks can be shipped with maximum load if enterprise packaging is used (models 1242E and 1042E).

     Relevant Standards Supported
     EIA 310-D




2
ORACLE DATA SHEET




    Sun Rack II Power Distribution Unit Specifications
    Oracle offers a selection of 8 easy-to-install PDUs.


    Specifications for Low-Voltage PDUs
                              10 kVA                         15 kVA                      15 kVA        37 kVA
                               1 ph                           1 ph                        3 ph          3 ph
    Amps per                    48 A                          72 A                        69 A          180 A
    PDU                      (2 × 24 A)                    (3 × 24 A)                  (3 × 23 A)     (9 × 20 A)
                              42 C13                        42 C13                      42 C13         45 C13
    Outlets
                             and 6 C19                     and 6 C19                   and 6 C19      and 9 C19
    Number of                Two 30 A,                     Three 30 A,                 One 60 A,     Three 60 A,
    Inputs                     1 ph                           1 ph                       3 ph           3 ph
                             24 A max.                   24 A max. per               40 A max. per   34.6 A max.
    Current
                              per input                      input                       phase        per phase
                                                                                       IEC 309-        IEC 309-
    Data Center                NEMA                          NEMA                     3P4W-IP67       3P4W-IP67
    Receptacle                L6-30R                         L6-30R                   60 A, 250 V    60 A, 250 V
                                                                                       AC, 3 ph       AC, 3 ph
    Rack                    Models 1242                  Models 1242
                                                                                      Model 1242     Model 1242
    Compatibility            and 1042                     and 1042

    Specifications for High-Voltage PDUs
                              10 kVA                         22 kVA                      15 kVA        37 kVA
                               1 ph                           1 ph                        3 ph          3 ph
    Amps per                    48 A                          96 A                       62.7 A         163 A
    PDU                      (2 × 24 A)                    (3 × 32 A)                 (3 × 20.9 A)   (9 × 18.1 A)
                              42 C13                        42 C13                      42 C13         45 C13
    Outlets
                             and 6 C19                     and 6 C19                   and 6 C19      and 9 C19
    Number of                Two 25 A,                     Three 32 A,                 One 25 A,     Three 25 A,
    Inputs                     1 ph                           1 ph                       3 ph           3 ph
                             25 A max.                   32 A max. per               25 A max. per    18 A max.
    Current
                              per input                      input                       phase        per phase
                             IEC 309-                       IEC 309-                   IEC 309-        IEC 309-
    Data Center             2P3W-IP44                      2P3W-IP44                  4P5W-IP44       4P5W-IP44
    Receptacle              32 A, 250 V                    32 A, 250 V                32 A, 400 V    32 A, 400 V
                                AC                             AC                      AC, 3 ph       AC, 3 ph
    Rack                    Models 1242                  Models 1242
                                                                                      Model 1242     Model 1242
    Compatibility            and 1042                     and 1042




Warranty
                                               warranty support information on Sun products.



Services




3
ORACLE DATA SHEET




Contact Us
For more information about [insert product name], visit oracle.com or call +1.800.ORACLE1 to speak to an Oracle representative.




Copyright © 2012, Oracle and/or its affiliates. All rights reserved.

This document is provided for information purposes only and the contents hereof are subject to change without notice. This document is not warranted to be error-free, nor subject
to any other warranties or conditions, whether expressed orally or implied in law, including implied warranties and conditions of merchantability or fitness for a particular purpose.
We specifically disclaim any liability with respect to this document and no contractual obligations are formed either directly or indirectly by this document. This document may not
be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without our prior written permission.

Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks of their respective owners.

AMD, Opteron, the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices. Intel and Intel Xeon are trademarks or registered
trademarks of Intel Corporation. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. UNIX is a registered
trademark licensed through X/Open Company, Ltd. 1010




4

More Related Content

PDF
2000 Iw
PDF
GarrettCom 10KT Substation Switch Now Available
PDF
Eti products 02 2012 copy
PDF
Catalog MCB Shillin Electric - beeteco.com
PDF
ComNet FDX55S1 Data Sheet
PDF
3 vt 1..5
PDF
2000 Iw
GarrettCom 10KT Substation Switch Now Available
Eti products 02 2012 copy
Catalog MCB Shillin Electric - beeteco.com
ComNet FDX55S1 Data Sheet
3 vt 1..5

What's hot (19)

PDF
Vestas v112-3.0_mw
PDF
Es9300
PDF
Teco electric motor manual
PDF
Mcb price list_electrical_installations_a_to_z_w.e.f_1st_sep_2016
PDF
Cisco router 1941 series datasheet
PDF
데이타로직 Datalogic DS6300 1D 산업용 고정식 바코드스캐너 레이저스캐너 매뉴얼
PDF
30@30: April Newsletter
PDF
Edwards Signaling E-NAC Data Sheet
PDF
Inovative Solution by Transformers Manufacturers in India
PDF
Cfs0065 ccat-r1-4 part7
PDF
Blue Line Supermicro Superblade
PDF
Sicop datasheet
PDF
01. hrc din fuses 3 na
PDF
01. superswitch switch disconnector fuse and din bs fuses
PDF
ABB Medium Voltage MV Surge Arresters - AC & DC Surge Arresters & Protection...
PDF
Aruba 2530 Switch Series Data Sheet
PDF
Trio tm-50.0 60.0-bcd.00658_en_rev_e
Vestas v112-3.0_mw
Es9300
Teco electric motor manual
Mcb price list_electrical_installations_a_to_z_w.e.f_1st_sep_2016
Cisco router 1941 series datasheet
데이타로직 Datalogic DS6300 1D 산업용 고정식 바코드스캐너 레이저스캐너 매뉴얼
30@30: April Newsletter
Edwards Signaling E-NAC Data Sheet
Inovative Solution by Transformers Manufacturers in India
Cfs0065 ccat-r1-4 part7
Blue Line Supermicro Superblade
Sicop datasheet
01. hrc din fuses 3 na
01. superswitch switch disconnector fuse and din bs fuses
ABB Medium Voltage MV Surge Arresters - AC & DC Surge Arresters & Protection...
Aruba 2530 Switch Series Data Sheet
Trio tm-50.0 60.0-bcd.00658_en_rev_e
Ad

Similar to Data sheet rack (20)

PDF
Ia r6000-c-r1-1
PDF
Ia r6000-c-r1-1
PDF
Aet series
PDF
cisco-asr-9006-dc-v2-datasheet.pdf
PPTX
Part1-Optix OSN 9800 Product Overview.pptx
PDF
神州数码 Jason pan future_clouddatacenterv2
PDF
Cisco Live! :: Cisco ASR 9000 Architecture :: BRKARC-2003 | Milan Jan/2014
PDF
Enphase iq7 and iq7plus data sheet iq7 iq7plus-ds-en-us
PDF
Original Power Supply IC TOP244YN TOP244Y TOP244 TO-220-7 New Power Integrations
PDF
P89 lpc920 921_922_9221
PDF
SMA 60kW Tri Power
PDF
Vacon nxl-brochure-bc00089 d-en
PDF
NetSure-502-Brochure
PDF
Cisco 1921 series router datasheet
PDF
Cisco 1921 series key features & benefits
PDF
Cisco 1900 series router datasheet
PDF
huawei-ce7855-ei-b-b0a-brochure-datasheet.pdf
PDF
Top242.250
PDF
cisco-c9300-48u-e-datasheet.pdf
PDF
Aruba 2920 Switch Series Data Sheet
Ia r6000-c-r1-1
Ia r6000-c-r1-1
Aet series
cisco-asr-9006-dc-v2-datasheet.pdf
Part1-Optix OSN 9800 Product Overview.pptx
神州数码 Jason pan future_clouddatacenterv2
Cisco Live! :: Cisco ASR 9000 Architecture :: BRKARC-2003 | Milan Jan/2014
Enphase iq7 and iq7plus data sheet iq7 iq7plus-ds-en-us
Original Power Supply IC TOP244YN TOP244Y TOP244 TO-220-7 New Power Integrations
P89 lpc920 921_922_9221
SMA 60kW Tri Power
Vacon nxl-brochure-bc00089 d-en
NetSure-502-Brochure
Cisco 1921 series router datasheet
Cisco 1921 series key features & benefits
Cisco 1900 series router datasheet
huawei-ce7855-ei-b-b0a-brochure-datasheet.pdf
Top242.250
cisco-c9300-48u-e-datasheet.pdf
Aruba 2920 Switch Series Data Sheet
Ad

More from makerios7 (13)

PDF
Data sheets lector biometrico
PDF
Data sheet patch panel de fibra optica
DOCX
Jacks,patch cord, data sheets
PDF
Data sheets patch panel
PDF
Data sheets cable cat5e
PDF
Data sheet servidores
DOCX
Analizador de espectros
DOCX
Analizador de espectros
DOCX
Modulacion am y fm
DOCX
Modulacion am y fm
DOCX
Modulacion am y fm
DOCX
Compuertas logicas
DOC
Campo electromagnetico
Data sheets lector biometrico
Data sheet patch panel de fibra optica
Jacks,patch cord, data sheets
Data sheets patch panel
Data sheets cable cat5e
Data sheet servidores
Analizador de espectros
Analizador de espectros
Modulacion am y fm
Modulacion am y fm
Modulacion am y fm
Compuertas logicas
Campo electromagnetico

Data sheet rack

  • 1. ORACLE DATA SHEET SUN RACK II KEY BENEFITS Th  ease  of  use,   OPTIMIZE YOUR SPACE flexibility,  and  optimal  application  of  your  limited  space  to  bring  better  ROI   Optimization for vertical density and  utilization  to  your  IT  infrastructure.  Offering  42U  capacity,  these   Choice of 1,058 mm or 1,200 mm depth innovative,  industry-­standard  19-­inch  racks  pack  a  maximum  number  of   Highest-capacity power in two of the smallest footprints available components,  cables,  and  accessories  into  two  fl Easy-to-install, compact PDUs with providing  the  power  infrastructure  you  need.   phase-current metering capabilities Ease of use and maintenance in robust and safe designs capable of shipping fully loaded Consistency with the latest Oracle rack- mount products for a uniform look in the data center Designed for vertical density, the Sun Rack II provides a minimized footprint for optimization of data center space. Sun Rack II Product Overview The Sun Rack II product line is well suited to a variety of data center environments. This robust and cost-effective family of racks is optimized for vertical density and provides a uniform appearance in your data center when installed with the latest Oracle servers and storage products. The racks can be purchased with a strong shipping pallet for transport when fully integrated with components. They offer an assortment of zero-RU, easily installed, metered power distribution units (PDUs) for maximal rack power capacity in a minimal footprint. In addition, they have been optimized for cooling, and both the front and rear doors have 80 percent perforations that provide a high level of airflow through the rack. Sun Rack II Features The Sun Rack II includes the following features: 42U height, choice of 1,058 mm or 1,200 mm depth, and 600 mm width, with industry-standard 19-inch adjustable square-hole RETMA rails to accommodate most Oracle and third party rack-mountable IT equipment Selection of zero-RU PDU options with various input and output connectors, providing the highest density in the lowest profile
  • 2. ORACLE DATA SHEET 80 percent door perforations, enabling a high level of airflow through the cabinet Extruded aluminum frame and reduced rack height, making the rack relatively light and easy to handle and enabling it to be safely rolled through most standard doorways 2,215 lb. (1,005 kg) maximum load a rugged platform users can populate with more components; available with enterprise packaging for safe shipment Sun Rack II Specifications PDUs A selection of 8 PDUs, from 10 kVA to 37 kVA, is available in single- and three-phase, low- and high-voltage versions, with 14 to 45 C13 and two to 9 C19 outlets available on a single PDU. Designed for quick and easy installation, each easy-to-mount PDU takes up zero RU, enabling high vertical density and providing unobstructed access to rear FRUs and accessories. The flexibility to add or change PDUs based on new data center wiring means that the rack can be upgraded with higher-density PDUs. Rack-level power metering capability* with an LCD PDU display screen and a remote network connection and the ability to set threshold and alarm levels prevents overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the PDU strip Stabilization Features Two foldaway anti-tilt bars inside the rack to ensure balance and prevent tipping during equipment service from the front Four leveling feet that can be lowered to the floor Four floor-mounting brackets for extra safety Dimensions Model 1242 Model 1042 Height: 199.8cm (78.7 in.) Height: 199.8cm (78.7 in.) Width: 60cm (23.6 in.) Width: 60cm (23.6 in.) Depth: 120cm (47.2 in.) Depth: 105.8cm (41.66 in.) Weight: 150.6 kg (332 lbs.) empty Weight: 123.4 kg (272 lbs.) Models 1242 and 1042 Usable rack units 42 685.8mm (27 in.) adjustable from Depth between front and rear RETMA rails 61.5mm(24.2 in.) to 825.8mm (32.4 in.) Maximum dynamic load** 1,005 kg (2,215 lbs.) Maintenance access requirement from rear 91.4cm (36 in.) Maintenance access requirement from top 91.4cm (36 in.) ** Racks can be shipped with maximum load if enterprise packaging is used (models 1242E and 1042E). Relevant Standards Supported EIA 310-D 2
  • 3. ORACLE DATA SHEET Sun Rack II Power Distribution Unit Specifications Oracle offers a selection of 8 easy-to-install PDUs. Specifications for Low-Voltage PDUs 10 kVA 15 kVA 15 kVA 37 kVA 1 ph 1 ph 3 ph 3 ph Amps per 48 A 72 A 69 A 180 A PDU (2 × 24 A) (3 × 24 A) (3 × 23 A) (9 × 20 A) 42 C13 42 C13 42 C13 45 C13 Outlets and 6 C19 and 6 C19 and 6 C19 and 9 C19 Number of Two 30 A, Three 30 A, One 60 A, Three 60 A, Inputs 1 ph 1 ph 3 ph 3 ph 24 A max. 24 A max. per 40 A max. per 34.6 A max. Current per input input phase per phase IEC 309- IEC 309- Data Center NEMA NEMA 3P4W-IP67 3P4W-IP67 Receptacle L6-30R L6-30R 60 A, 250 V 60 A, 250 V AC, 3 ph AC, 3 ph Rack Models 1242 Models 1242 Model 1242 Model 1242 Compatibility and 1042 and 1042 Specifications for High-Voltage PDUs 10 kVA 22 kVA 15 kVA 37 kVA 1 ph 1 ph 3 ph 3 ph Amps per 48 A 96 A 62.7 A 163 A PDU (2 × 24 A) (3 × 32 A) (3 × 20.9 A) (9 × 18.1 A) 42 C13 42 C13 42 C13 45 C13 Outlets and 6 C19 and 6 C19 and 6 C19 and 9 C19 Number of Two 25 A, Three 32 A, One 25 A, Three 25 A, Inputs 1 ph 1 ph 3 ph 3 ph 25 A max. 32 A max. per 25 A max. per 18 A max. Current per input input phase per phase IEC 309- IEC 309- IEC 309- IEC 309- Data Center 2P3W-IP44 2P3W-IP44 4P5W-IP44 4P5W-IP44 Receptacle 32 A, 250 V 32 A, 250 V 32 A, 400 V 32 A, 400 V AC AC AC, 3 ph AC, 3 ph Rack Models 1242 Models 1242 Model 1242 Model 1242 Compatibility and 1042 and 1042 Warranty warranty support information on Sun products. Services 3
  • 4. ORACLE DATA SHEET Contact Us For more information about [insert product name], visit oracle.com or call +1.800.ORACLE1 to speak to an Oracle representative. Copyright © 2012, Oracle and/or its affiliates. All rights reserved. This document is provided for information purposes only and the contents hereof are subject to change without notice. This document is not warranted to be error-free, nor subject to any other warranties or conditions, whether expressed orally or implied in law, including implied warranties and conditions of merchantability or fitness for a particular purpose. We specifically disclaim any liability with respect to this document and no contractual obligations are formed either directly or indirectly by this document. This document may not be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without our prior written permission. Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks of their respective owners. AMD, Opteron, the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices. Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. UNIX is a registered trademark licensed through X/Open Company, Ltd. 1010 4