A Dell EMC VXLAN Technical White Paper 1
VXLAN Technical Brief
A standard based Data Center Interconnection solution
Dell EMC Networking – Data Center Technical Marketing
February 2017
A Dell EMC VXLAN Technical White Paper 2
THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL
ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS
OR IMPLIED WARRANTIES OF ANY KIND.
© Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell and the Dell EMC logo are
trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names
mentioned herein may be trademarks of their respective companies.
A Dell EMC VXLAN Technical White Paper 3
Table of contents
Introduction ...................................................................................................................................................5 
Spanning Tree and VLAN Range Limitations .................................................................................5 
Multi-tenancy.........................................................................................................................................5 
Objective .......................................................................................................................................................6 
VXLAN Overview RFC 7348 – Why? ......................................................................................................6 
VNI – VXLAN Network Identifier........................................................................................................ 7 
VTEP – VXLAN Tunnel End Point .................................................................................................... 7 
Multicast ................................................................................................................................................. 7 
Layer 3 routing protocol....................................................................................................................... 7 
Quality of Service (QoS) ..................................................................................................................... 7 
VXLAN Encapsulation and Packet Format............................................................................................. 7 
Components of VXLAN Frame Format ............................................................................................8 
Feature Comparison – 802.1Q VLAN vs. VXLAN.........................................................................9 
VTEP (VXLAN Tunnel Endpoint) Overview..........................................................................................10 
Software Based VTEP Gateway.......................................................................................................11 
Hardware Based VTEP Gateway.....................................................................................................11 
VTEP Packet Forwarding Flow............................................................................................................... 13 
Dell EMC VXLAN Architecture................................................................................................................14 
Dell EMC VTEP Architecture on the S and Z series Data Center Switches .................................. 15 
Deployment Considerations/Guidelines......................................................................................... 17 
Dell EMC HW-Based VXLAN Gateway/VTEP Deployment Options ............................................... 17 
Option 1: Dell EMC Layer 2 HW-Based VTEP GW with Controller OS 9.10..........................18 
Option 2: Dell EMC Layer 2 HW-Based VTEP GW w/out controller (Static VXLAN Tunnels)
OS 9.11 ................................................................................................................................................19 
BUM Data Packet Handling..............................................................................................................19 
Unicast Data Packet Handling .........................................................................................................19 
MAC learning.......................................................................................................................................20 
Caveats ............................................................................................................................................... 21 
Conclusion ..................................................................................................................................................22 
Figure 1  VXLAN Frame Format............................................................................................................................ 8 
Figure 2  VTEP Function Diagram.......................................................................................................................11 
Figure 3  VXLAN Unicast Packet Flow................................................................................................................13 
A Dell EMC VXLAN Technical White Paper 4
Figure 4  Dell EMC EMC VXLAN Tunnel End-Point (VTEP) Implementation .............................................16 
Figure 5  Current Deployment - Dell EMC Hardware-Based L2 VTEP with NVP controller.................... 18 
Figure 6  Local MAC address learning...............................................................................................................20 
Figure 7  Remote MAC address learning ..........................................................................................................20 
Figure 8  Current Dell EMC Hardware-Based VTEP w/out VLT....................................................................21 
Table 1  802.1 Q VLAN and VXLAN Comparison ............................................................................................ 9 
Table 2  Software vs. Hardware VTEP comparison........................................................................................12 
Table 3  Dell EMC Static VXLAN current guidelines.......................................................................................21 
Table 4  Dell EMC Hardware-Based VTEP with Controller vs. without Controller comparison............. 22 
A Dell EMC VXLAN Technical White Paper 5
Introduction
In the information technology field often when a new technology is created to address a need, an
enhancement or complementary technology is created.
The best example of this is virtualization (network and resources) in the data center. Prior to
virtualization, traditional network segmentation was provided through VLANs (Virtual Local Area
Networks) where a set of hosts or a single host would be assigned to a different VLAN ID in order to
segment them from each other. If these hosts wanted to communicate with each other; inter-vlan routing
would be required.
There are inherent shortcomings when using VLANs, such as inefficient network inter-links, spanning tree
limitations, physical location of devices, limited number of VLANs (4,094), multi-tenant environments, and
ToR (Top of Rack) switch scalability. VLANs have become a limiting factor for IT departments and
providers as they look to build efficient and highly scalable multitenant data centers where server
virtualization is a key critical component.
Spanning Tree and VLAN Range Limitations
A typical data center uses a Layer 2 design to facilitate inter-VM communication. This usually results in
the presence of the spanning tree protocol to avoid network loops due to duplicate network paths.
Spanning tree renders half of the data center network fabric useless since it blocks half of the links to
avoid network traffic replication that could cause looping of frames. This increases TCO (Total Cost
Ownership), effectively paying for ports that will not be used.
In addition to spanning tree, the typical Layer 2 network uses VLANs to provide basic broadcast isolation.
The traditional VLAN implementation uses a 12-bit field ID used to separate a large layer 2 domain into
separate broadcast domains. This allows for a VLAN ID range of 1 – 4,094. For a small data center
environment, this range is usually not an issue; however, with the increased virtualization adoption rate in
today’s data center and multi-tenant requirements the traditional VLAN range simply cannot scale.
Multi-tenancy
It wasn’t long ago when the word cloud computing was just a “buzz” word or a “concept” found in niche
areas around service providers willing to try out new bleeding edge technologies. Today, cloud computing
is as normal of a concept to most enterprise organizations as the internet is to the average individual. It
provides a list of benefits that when properly leveraged becomes a valued asset.
One of the primary drivers of cloud computing is the concept of “elasticiticy”. This on-demand elastic
provisioning - addition and or removal - of resources for multi-tenant applications makes cloud computing
an opportunity for organizations to offload their IT infrastructure to a cloud service provider. Unfortunately,
the use of traditional VLANs creates a scalability problem due to the typically large number of tenants
supported within the same data center. Since VLANs are used to isolate traffic between the different
tenants, limitation of 4,094 VLAN IDs often inadequate.
Although Layer 3 networks can sometimes be leveraged to address the VLAN range limitation, it is not
atypical to find two different tenants requiring the same Layer 3 ip addressing scheme due to legacy
applications, network design requirements, or inherited requirements.
A Dell EMC VXLAN Technical White Paper 6
The IEEE has proposed potential initiatives such as TRILL (Transparent Interconnection of Lots of Links),
or SPB (Shortest Path Bridging) to address traditional spanning tree shortcomings. However these
initiatives have not been widely adopted.
What can be done to resolve these issues? Enter VXLAN (Virtual Extensible LAN), a standard officially
documented by the IETF as an open standards solution to resolve these shortcomings.
Dell EMC with its data center networking product portfolio switches, such as the fixed-configuration Dell
EMC S6000 Series, S4048-ON, Z9100-ON, and S6100-ON have been designed for the next-generation
data center with hardware-based VXLAN functionality.
HW-based VXLAN extend Layer 2 connectivity across a Layer 3 boundary while keeping seamless
integration between VXLAN and non-VXLAN environments. Together, these switches form the physical
network underlay building blocks of a scalable virtualized and multitenant data center.
Objective
The objective of this short technical brief document is to provide an overview of VXLAN, its components,
and Dell EMC’s architecture and solutions.
VXLAN Overview RFC 7348 – Why?
If VXLAN is yet another important technology introduced that extends and enhances the traditional
802.1Q VLAN feature set, how does VXLAN add more value or becomes a powerful tool besides
enhancing what 802.1Q VLAN provides?
The answers to the questions lay in the following problem statement: “How can I as a network
administrator or engineer stretch my Layer 2 reach across multiple data centers and not worry about
running out of vlan IDs or using duplicate vlan IDs?”
VXLAN answers the questions through the use of what is referred as “encapsulation” running over an
existing networking infrastructure (Layer 3) to provide a means of stretching a Layer 2 network across
different data centers. The RFC defines VXLAN “…as a Layer 2 overlay scheme on a Layer 3
network...” where each overlay is referred as a VXLAN segment and each segment is identified through
a 24-bit segment ID referred to as a VNI (VXLAN Network Identifier). This allows potentially up to 16
Million VXLAN segment IDs far greater than the traditional 4,094 VLAN IDs.
There are five key elements used within VXLAN as part of its implementation:
 VNI (VXLAN Network Identifier)
 VTEP (VXLAN Tunnel End Point)
 Multicast support – IGMP and PIM
 Layer 3 routing protocol – OSPF, BGP, IS-IS
 QoS
A Dell EMC VXLAN Technical White Paper 7
VNI – VXLAN Network Identifier
The VNI is part of the outer header that encapsulates the inner MAC frame sourced by the VM. The VNI
is a unique combination of host or VM MAC SOURCE ADDRESS and VXLAN segment ID that identifies a
single VM or physical host. It is so unique that it allows for duplicate source MAC addresses to coexist in
the same administrative domain. For example, a VM with source MAC_A and VXLAN segment ID 5000
is completely different from a VM or physical host with source MAC_A and VXLAN segment ID 5001.
VTEP – VXLAN Tunnel End Point
VXLAN as an “encapsulation” scheme is also referred as a “tunneling” scheme and like any tunneling
implementation there has to be a starting and end point to the tunnel. To this end VXLAN implements a
VTEP in software or hardware. The VTEP uses information from the outer IP header to route or switch
traffic from the VMs or physical host. (See Figure 1)
Multicast
Multicast is needed whenever a VM or host attempts to communicate with another VM or host over Layer
3 (IP) or Layer 2. Typically, if the destination VM or host is in the same subnet the source VM or host will
send out an ARP broadcast packet. In a non-VXLAN environment, this frame is simply broadcast across
all devices carrying that VLAN.
In a VXLAN environment, a broadcast ARP packet is sent to a multicast group address. A VXLAN VNI is
mapped to this multicast address group. This mapping is then sent to each VTEP. Once the VTEP has
this mapping it is used to provide IGMP membership reports to the upstream switch/router to join/leave
the specific multicast group of interest by the VMs or hosts.
The infrastructure should be able to meet the multicast requirements, whether it is Layer 3 such as
Protocol Independent Multicast – Sparse Mode (PIM-SM) or Layer 2 such as IGMP Snooping.
Layer 3 routing protocol
As an encapsulation and tunneling scheme, VXLAN is a layer 2 scheme over a layer 3 infrastructure. As
a result basic layer 3 routing protocols such as BGP, OSPF, or IS-IS are part of any VXLAN deployment.
Quality of Service (QoS)
As VXLAN packets traverse the Layer 3 domain carrying with them specific types of traffic/applications
and specific level of service, it is imperative that these level of services are not only honored but
translated onto the VXLAN IP outer header.
This level of service translate as DSCP values where the external physical network infrastructure uses to
prioritize the traffic based on the DSCP setting on the IP outer header.
VXLAN Encapsulation and Packet Format
VXLAN packets are encapsulated over a UDP packet through the use of MAC Address-in-User Datagram
Protocol (MAC-in-UDP) and tunneled across different data centers using virtual end point tunnels which
will be discussed later on in the document.
A Dell EMC VXLAN Technical White Paper 8
The transport protocol used is IP plus UDP.
As noted before, VXLAN defines a MAC-in-UDP encapsulation format where the original Layer 2 frame
from the source VM has a VXLAN header added and is then encapsulated again in a UDP-IP packet.
Figure 1, shows the entire VXLAN Frame format and the related encapsulations over the original Layer 2
frame. Notice how each header is used by the different components as the packet traverses from source
to destination.
This section breaks down the individual headers that make up the entire VXLAN packet and their
respective components.
Figure 1 VXLAN Frame Format
Components of VXLAN Frame Format
Some of the important fields of the VXLAN frame format are:
Outer Ethernet Header/Outer MAC Header: The Outer Ethernet Header consists of the following:
 Destination Address: Generally, it is a first hop router’s MAC address when the VTEP is
on a different address.
 Source Address: It is the source MAC address of the router that routes the packet.
 VLAN Type and ID: It is optional in a VXLAN implementation and will be designated by
an ethertype of 0x8100 and has an associated VLAN ID tag.
 Ethertype: It is set to 0x8100 because the payload packet is an IPv4 packet. The initial
VXLAN draft does not include an IPv6 implementation, but it is planned for the next draft.
Outer IP Header: The Outer IP Header consists of the following components:
 Protocol: It is set to 0x11 to indicate that the frame contains a UDP packet.
 Source IP: It is the IP address of originating VTEP over which the communication VM is
running.
 Destination IP: It is the IP address of the target VTEP. This address can be unicast or
multicast. A unicast address represents the destination VTEP. A multicast address
A Dell EMC VXLAN Technical White Paper 9
represents the VXLAN VNI and the IP multicast group mapping for broadcast
communication between VMs or hosts in different domains.
Outer UDP Header: The Outer UDP Header consists of the following components:
 Source Port: Entropy of the inner frame. The entropy or variability scheme could be
based on the inner L2 header or inner L3 header. This value or source port number is to
enable a level of uncertainty when it comes to load balancing of VM-to-VM traffic across
the VXLAN overlay.
 VXLAN Port: IANA-assigned VXLAN Port (4789).
 UDP Checksum: The UDP checksum field is transmitted as zero. When a packet is
received with a UDP checksum of zero, it is accepted for de-capsulation.
VXLAN Header: The VXLAN Header consists of the following components:
 VXLAN Flags: Reserved bits (8bits), set to zero except bit 3, the first bit is set to 1 for a
valid VNI.
 VNI: The 24-bit field that is the VXLAN Network Identifier.
 Reserved: A set of fields, 24 bits and 8 bits that are reserved and set to zero.
Frame Check Sequence (FCS): The original Ethernet frame’s FCS is not included, but new FCS is
generated on the outer Ethernet frame.
Feature Comparison – 802.1Q VLAN vs. VXLAN
Table 1, shows the enhancements between the typical VLAN and VXLAN feature set. Each of the entries
should be taken into consideration whenever deploying VXLAN in the network.
Table 1 802.1 Q VLAN and VXLAN Comparison
Feature and Scaling 802.1Q VLAN VXLAN
Max ID Range 4,000 limited by spanning-tree
scaling
16M, limited by the number of
multicast groups supported by
network devices
Packet Size 1.5K or 9K, some devices
support up to 12K
50 additional bytes for VXLAN
header
Multicast Requirements None PIM, SM, DM, or Bi-dir. Many
VNIs to a single multicast
group mapping supported
Routing Support Any Layer 2 or Layer 3 capable
device
Any Layer 3 or Layer 2
compatible with VMware
vShield, vEdge, and any VTEP
capable networking device
such as the Dell EMC S6000,
S4048-ON, and S6100-ON
ARP Cache Limits the VMs supported per
VLAN
Cache size on VMware or
VTEP devices limits VMs
supported per VNI
Duplicate IP across different
logical segments
N/A Yes
A Dell EMC VXLAN Technical White Paper 10
Duplicate MAC address across
logical segments
N/A Yes
Duplicate VLAN IDs across
different logical segments
N/A Yes
VTEP (VXLAN Tunnel Endpoint) Overview
So far, we have answered the question of why VXLAN is needed but we have not answered why it is also
considered a tunneling scheme?
VXLAN as noted before is an encapsulation and tunneling scheme and as such an entity to
encapsulate/decapsulate and originate/terminate the tunnel is needed. The encapsulation requirement
has been discussed in the VXLAN overview section and now we need to discuss how this encapsulated
traffic is handled.
Most of today’s data center consists of a mixture of virtualized and non-virtualized compute resources.
We also know that these virtualized environments MUST be able to communicate with non-virtualized
environments. It is not possible to have a homogeneous data center from the applications, resources, or
infrastructure point of view.
In a typical data center, a virtualized server has several VMs and they communicate with each other
through what is called a vSwitch (virtual Switch). This vSwitch is the first hop for all the VMs and
implements the network virtualization part of a virtual environment. Unfortunately, this vSwitch construct
does not exist on a non-virtualized server or bare-metal server and therefore establishing any sort of
communication between a virtualized and non-virtualized compute resource is not possible unless some
type of appliance or gateway device can serve as a bridge between these two different environments.
To bridge this gap, the VXLAN RFC introduced the concept of a VXLAN Tunnel Endpoint or VTEP. This
entity has two logical interfaces: an uplink and downlink. The uplink interface receives VXLAN frames and
acts as the tunnel endpoint with an IP address used for routing VXLAN encapsulated frames. The IP
address assigned to this uplink interface is part of the network infrastructure and completely separate
from the VMs or tenants IP addressing using the VXLAN fabric.
Packets received on the uplink interface are mapped from the VXLAN ID to a VLAN and the Ethernet
payload is then sent as a typical 802.1Q Ethernet frame on the downlink to the final destination. As this
packet passes through the VTEP a local table is created with the inner MAC SOURCE ADDRESS and
VXLAN ID. Packets that arrive at the downlink interface are used to create a VXLAN ID to regular VLAN
map.
A Dell EMC VXLAN Technical White Paper 11
Figure 2 VTEP Function Diagram
There are two types of VTEPs that have been introduced in the industry, a software and hardware based
VTEP Gateway:
Software Based VTEP Gateway
The software based VTEP runs as a separate appliance and it typically runs on a standard x86 hardware
with an instance of Open vSwitch. This VTEP is under a controller and it maps physical ports and VLANs
on those ports to logical networks. Through this map, VMs that are part of the same logical network can
now communicate with the physical device that belongs to the same logical network. This is the
approach taken by several overlay architecture such as VMware NSX-v, Midokura, and others.
Software based VTEPs are a great solution for fairly moderate amounts of traffic between VMs and
physical devices.
Hardware Based VTEP Gateway
When a full rack of physical servers running database applications need to connect to logical networks
containing VMs, ideally these bare metal servers will need a high-density and high-performance switch
that could bridge/switch these traffic patterns between the physical servers and logical segments. This is
where hardware based VTEPs make sense – migration and interoperability of legacy applications. The
hardware based VTEP is no different than the software based VTEP in terms of functionality and
controller interaction. A controller which has visibility into the virtualized environment is used to integrate
the hardware VTEP and thus creates the gateway functionality required between the virtual and non-
virtual environments.
A Dell EMC VXLAN Technical White Paper 12
With hardware-based VTEP, the VTEP functionality is implemented in the hardware ASIC resulting in a
performance and scalability advantage.
There are two types of VTEP functionalities: Layer 2 and Layer 3. As a Layer 2 VTEP gateway, it
provides both encapsulation and de-capsulation of legacy or traditional Ethernet and VXLAN packets
respectively and allows the stretch of a Layer 2 domain across a Layer 3 domain. Tagged packets
configured with a VLAN ID are mapped to a respective VNI entry encapsulated with a VXLAN header.
As a Layer 2 VTEP gateway, VMs or hosts from VXLAN segment X cannot communicate with a different
VM or host in VXLAN segment Y in order for this communication to take place, a router or Layer 3 device
is needed and all routing functions will be performed based on the outer most IP header (see VXLAN
Packet Format).
As a Layer 3 VTEP gateway, it performs straight VXLAN segment X to VXLAN segment Y routing similar
to the traditional inter-VLAN routing providing communication between different VXLAN segments.
Contrary to how a Layer 2 VTEP gateway functions (VXLAN to VLAN mapping), a Layer 3 VTEP
gateway, performs routing using the VXLAN ID, there is no mapping dependency.
VXLAN routing is currently not widely supported with the current silicon. Currently, the most common type
of a VTEP GW deployment is as a Layer 2 VTEP gateway with VXLAN routing support to take place with
later software releases and newer silicon ASICs.
Table 2 Software vs. Hardware VTEP comparison
Key Points Software VTEP Hardware VTEP
Virtual, physical, or both Virtual Physical
Scalability Moderate traffic between VMs Moderate to heavy traffic
between VMs and physical
servers
Orchestration Controller based Controller and non-controller
based
Performance CPU driven ASIC driven (Line rate)
A Dell EMC VXLAN Technical White Paper 13
VTEP Packet Forwarding Flow
Figure 3, shows an example of a VXLAN packet forwarding flow. Notice how the outer headers are used
at the respective phases as the packet flows from VTEP 1 to VTEP 2.
Figure 3 VXLAN Unicast Packet Flow
Host-A and Host-B belong to the same VXLAN segment ID 20 and communicate with each other through
the VXLAN tunnel created between VTEP-1 and VTEP-2.
Step 1 – Host-A sends traffic to Host-B, it creates an Ethernet frame with Host-B’s destination MAC and
IP address and sends it towards VTEP-1.
Step 2 – VTEP-1 upon receiving this Ethernet frame has a map of Host-B’s MAC address to VTEP-2.
VTEP-1 performs the VXLAN encapsulations by adding the respective headers such as VXLAN, UDP,
and outer IP headers.
Step 3 – Using the information in the outer IP headers, VTEP-1 performs an IP address lookup for VTEP-
2’s address to resolve the next-hop in the transit or IP network. Using the outer MAC header information,
VTEP-1 sees the router’s MAC address as the next-hop device.
Step 4 – The Ethernet frame is routed towards VTEP-2 based on the outer IP header which has VTEP-2’s
IP address as the destination address.
Step 5 – After VTEP-2 receives the Ethernet frame, it decapsulates all the headers and forwards the
packet to Host-B using the original destination MAC address.
A Dell EMC VXLAN Technical White Paper 14
Dell EMC VXLAN Architecture
Dell EMC networking’s data center product portfolio provides a solid feature set for the data center. With
the Dell EMC S and Z-series product families, Dell EMC supports the hardware-based VXLAN gateway
function allowing for the extension of Layer 2 connectivity across a Layer 3 transport network providing
predictable high-performance gateway between VXLAN and traditional VLAN environments.
Dell EMC’s VXLAN implementation is based on RFC 7348, it uses the existing Layer 2 mechanisms such
as flooding and dynamic MAC address learning to create the necessary underlay between VXLAN and
traditional VLAN environments.
The mechanisms are used to perform the following key functions which are very similar to other vendor’s
implementations:
 BUM (Broadcast, unknown unicast, and multicast) traffic handling
 Discovery/learn remote host/VM MAC addresses and MAC-to-VTEP mappings per VXLAN
segment
For each VXLAN segment, a map is created between the VXLAN segment and an IP multicast group.
This multicast group address is known by all the VTEPs that have knowledge of the VXLAN segment and
it is used by all BUM traffic from SA (Source Address) MACs to reach a Multicast Replicator Source
(MRS) or service node. It is the service node’s job to direct or service the join request received at the
VTEP by the end host or VM.
The NVP (Network Virtualization Platform) controller creates a multicast tunnel pointing to the service
node or multicast replicator. Each VTEP is programmed by the NVP controller to direct any incoming
BUM traffic to this service node through the multicast tunnel. A single packet copy is sent to each VTEP
as long as there is interest in joining a particular multicast group from hosts or VMs connected to these
VTEPs.
Dell EMC’s BUM traffic handling is further enhanced through the use of Bidirectional Forwarding
Detection (BFD) to ensure reachability towards the service nodes is guaranteed. In a typical overlay
deployment, a cluster of service nodes or MRSs is deployed in order to provide high-redundancy. Once
the Dell EMC hardware VTEP establishes a tunnel towards the service node, a BFD session is created
and communicated towards the NVP controller.
When it comes to VTEP discoveries, there are two approaches: Dynamic and Static. Dell EMC’s
implementation uses static configuration of the VTEPs (remote and local) via the NVP controller or
manually - via CLI on the device - configuring the remote VTEP when deploying static vxlan tunnels, i.e.
no NVP controller used (See Option 2: Dell EMC Layer 2 HW-Based VTEP GW w/out controller (Static
VXLAN Tunnels) OS 9.11) .
Through the use of a static approach the implementation avoids the need for yet another protocol to
discover the VTEPs.
As soon as the VTEPs have been configured on the NVP controller or statically configured via CLI on the
device (no NVP controller used) and IP reachability has been confirmed, local and remote MAC learning
takes place. During the learning phase, the SOURCE ADDRESS MAC address (local and remote) is
A Dell EMC VXLAN Technical White Paper 15
mapped to a single VTEP tunnel IP address and logical network/VXLAN segment using a slightly different
method.
For a remote SOURCE ADDRESS MAC address, when using a controller, the NVP controller creates a
remote SOURCE ADDRESS MAC to remote VTEP binding. If there is no controller, and static vxlan is
used, remote MAC learning on tunnels is derived from the inner SOURCE ADDRESS MAC of the
packet(s) received on the tunnel.
For a local SOURCE ADDRESS MAC address, when using a controller, the Dell EMC VTEP switch
informs the NVP controller through OVSDB protocol of the SOURCE ADDRESS MAC learned on a
specific port or VLAN and if no controller is used, local SOURCE ADDRESS MAC is done when a data
packet is received on the access port of the local VTEP device just like any other switch
The bindings of the SOURCE ADDRESS MAC(s) to VTEP are propagated by the NVP controller to the
VTEPs building a full mesh connectivity infrastructure. See Figure 4, on the specific steps about how the
Dell EMC VTEP GW implements this communication.
Dell EMC VTEP Architecture on the S and Z series Data
Center Switches
Dell EMC’s initial VTEP implementation is based on a client to server communication relationship
between an NVP (Network Virtualization Platform) and the VTEP. Later on, a different architecture non-
controller based is discussed.
In Dell EMC’s initial implementation, the NVP entity is the network orchestrator provided by VMware’s
NSX-v Platform.
The functions provided by the Dell EMC VTEP are the following:
1. Create all the necessary logical networks between the virtualized and non-virtualized
environments.
2. Identify and bind <Port, VLAN> to a logical network
3. Maintain the remote and local host MAC bindings to the respective VTEP
4. Establish communication and be managed by the NVP
5. Support standard communication protocol known as Open vSwitch Database (OVSDB) between
NVP and itself.
The functions provided by the NVP orchestrator are the following:
1. It connects to the NVP gateway/VTEP through a TCP connection which must be configured by
the user.
2. It orchestrates a Layer 2 network between the two VTEPs
a. Binds Port and VLAN
b. Installs VTEP tunnels between the hosts
c. Installs both the remote and local VM/host SOURCE ADDRESS MACs on the VTEPs
3. Monitors network database from the VTEPs
4. Pushes the BFD configuration for VXLAN tunnels created towards the service nodes
A Dell EMC VXLAN Technical White Paper 16
Figure 4, shows the implementation steps on the VTEP as two hosts initiate to communicate.
Figure 4 Dell EMC EMC VXLAN Tunnel End-Point (VTEP) Implementation
Step 1
User based VXLAN configuration is passed on to the NVP controller through the OVSDB protocol. The
configurations include, <port, vlan, VTEP information with respect to VXLAN configuration>. Dell EMC’s
VTEP implementation uses SSL certification between the Dell EMC VTEP and NVP prior to exchanging
any information.
Step 2
Based on the information received in Step 1, the NVP controller creates a logical network consisting of a
logical netwok ID, and VXLAN network ID or segment. The logical network and VXLAN ID/segment is
created by the NVP controller administrator, this configuration is not created automatically.
Step 3
Bind the port, VLAN, and VTEP information from Step 1, to the logical network(s) created in Step 2. In
other words, port X or VLAN Y participating on VXLAN instance Q from VTEP A bind to logical network M.
Step 4
Learn local MAC address on VTEP and create tunnel mapped to learned MAC address on the logical
network M. All locally learned MACs are advertised to the NVP controller with the VTEP IP
address/tunnel as the destination tunnel.
Step 5
NVP controller advertises the mapped information to the remote VTEP and the remote VTEP installs this
in its forwarding table.
A Dell EMC VXLAN Technical White Paper 17
Step 6
NVP controller repeats step 4 for remote VTEP’s host or VM and advertises this information to the Dell
EMC HW VTEP where the Dell EMC EMC VTEP installs this entry. The entry information contains the
remote SOURCE ADDRESS MAC, remote VTEP IP on which the remote SOURCE ADDRESS MAC has
been learned and the logical network.
As far as multicast, broadcast, unknown unicast traffic originated at the SOURCE ADDRESS MAC, the
NVP controller creates a multicast tunnel pointing to the service node or multicast replicator. Each VTEP
is programmed by the NVP controller to direct any incoming BUM traffic to this service node through the
multicast tunnel. A single packet copy is sent to each VTEP as long as there is any interest from hosts or
VMs connected to these VTEPs.
Deployment Considerations/Guidelines
Whenever deploying a Dell EMC HW based VTEP Gateway the following considerations or guidelines
should be taken:
1. Ensure Dell EMC S6000-ON or S4048-ON are running at least release OS 9.10 or above
2. Ensure IP connectivity is up between the NVP controller and the Dell EMC switch
3. Ensure VMware NSX build is 6.2.2 or later. NSX 6.2.2 supports HW based VTEP GW
4. Configure jumbo frames (Dell EMC MTU 9216) or elephant flow (1600 MTU) frame on all
devices creating the underlay. Most networking devices support up to 9216 byte MTU size.
Dell EMC HW-Based VXLAN Gateway/VTEP Deployment
Options
There is no denying that virtualization (compute and network) play a key role in today’s data centers. It
has transformed the data center from a sunken expense into a revenue generating asset. It has provided
enterprises business agility, competitive advantage, and most importantly efficient usage of resources.
Dell EMC’s networking data center product portfolio is designed to deliver on these benefits. The Dell
EMC S and Z series family support and function as a hardware-based VXLAN gateway. They seamlessly
bridge and connect VXLAN and VLAN segments as a single Layer 2 domain across a Layer 3
infrastructure without incurring any performance degradation. The current hardware supports up to 8,000
unique VNIDs and 511 tunnels. Each tunnel can carry multiple VNIDs.
Note: Although VXLAN allows up to 16M unique VNIDs or VXLAN segments, the current silicon supports
up to 8,000 unique VNIDs with 16M logical IDs available. The current number of VNIDs supported covers
the majority of today’s VXLAN to non-VXLAN environments deployments.
The key VXLAN encapsulation and de-capsulation function is hardware-based providing line-rate
performance regardless of frame size. Figures 5 and 6 show two key deployments of the hardware-based
VTEP configurations from the Dell EMC data center switches.
A Dell EMC VXLAN Technical White Paper 18
There are two supported HW-based VTEP GW solutions.
 Dynamic using an NVP (Network Virtualization Platform) controller such as VMware’s NSX-v to
establish the VTEP tunnels between the different data centers.
 Static using manually configured VTEP tunnels between the different data centers.
Option 1: Dell EMC Layer 2 HW-Based VTEP GW with Controller OS 9.10
Figure 5 shows the Dell EMC S and Z- series switches working in conjunction with the NVP controller
(VMware NSX) to setup dynamic VTEP tunnels between the Dell EMC hardware-based VTEP and the
software-based VTEP hypervisor allowing communication between the VMs and the physical server. The
dashed lines show the communication between the VTEPs (software or hardware-based) and the NVP
controller.
On the left side of the topology, the hypervisor VTEP or software based VTEP has dual links to the Dell
EMC S6000s. The Dell EMC S6000s are configured in a VLT (Virtual Link Trunk) domain creating a
virtual switch towards the software based VTEP hypervisor. This configuration provides redundancy at
the ToR, in this case the Dell EMC S6000s. Layer 3 is configured from the hypervisor to the core
consisting of a pair of Z9100s or S6000s.
Figure 5 Current Deployment - Dell EMC Hardware-Based L2 VTEP with NVP controller
A Dell EMC VXLAN Technical White Paper 19
Option 2: Dell EMC Layer 2 HW-Based VTEP GW w/out controller (Static
VXLAN Tunnels) OS 9.11
The second deployment type (see Figure 8) shows the Dell EMC S and Z switches as a point-to-point
static VXLAN tunnel. In this configuration, there is no controller present and all VTEP tunnels are created
manually/statically between the local and remote VTEPs. Although only S6000-ON and S40489-ON are
illustrated in each diagram, the entire S and Z series data center switch family supports static vxlan as
well.
Host or VM SOURCE ADDRESS_MAC learning is identical to a controller based deployment where the
SOURCE ADDRESS_MAC is learned as soon as data packet is received at the access port of the VTEP
switch. With static VXLAN, address learning is enabled by default.
Dell EMC EMC’s static vxlan implementation is efficient and uses simple logical network ID mapping with
a specific VTEP tunnel.
BUM Data Packet Handling
When a packet arrives on an access port with a destination MAC address being either a broadcast,
unknown unicast, or multicast (BUM) for which there is no knowledge on the VTEP switch which remote
VTEP tunnel to be used for the destination MAC address, the following steps are taken by the local VTEP
switch:
Step 1
Capture the logical network ID configured on this port or vlan interface on which the packet has been
received.
Step 2
Learn the SOURCE ADDRESS MAC address on this port or vlan interface.
Step 3
Send a unicast copy of the packet to each remote VTEP over the vxlan tunnel which is configured to be
part of this logical network. Also send a copy to any local access port that are also part of this logical
network.
Unicast Data Packet Handling
When a data packet arrives on an access port with a unicast destination MAC address, the following
steps are taken by the VTEP.
Step 1
The logical network ID is derived from the VLAN or port on which the packet has been received
Step 2
A lookup is performed in the Layer 2 entry table with the VFI and a unicast destination MAC address.
 If the lookup is successful and if the packet is destined to a local access port(s), the native packet
will be sent on the access port(s), however, if the packet is destined to a remote VTEP tunnel, the
packet is encapsulated with a VXLAN header with a VNID based VFI and the destination IP
A Dell EMC VXLAN Technical White Paper 20
address based on the remote VTEP tunnel and is sent out to the next hop along the path to the
remote VTEP tunnel
 If the lookup is unsuccessful, the same steps that apply to a BUM traffic is performed.
MAC learning
Local and remote SOURCE ADDRESS MAC learning happen at different places during data forwarding.
Local learning takes place when a data packet is received on the access ports. Whereas remote learning
takes place at the VTEP tunnel.
Learning is enabled by default and it cannot be disabled. The same applies with remote MAC learning
which is enabled on the VTEP tunnels.
For example, when a data packet is received on an access port, this SOURCE ADDRESS MAC address
is mapped to a specific VNID and ingress VTEP tunnel ip address. This piece of information (VNID,
SOURCE ADDRESS MAC, and VTEP tunnel ip) is programmed in the switch’s Layer 2 entry or
forwarding table.
Figures 7 & 8 show an output of both local and remote address learning per vxlan-instance. Note the
tunnel ID or ip address of the tunnel. This is the vtep tunnel on which the remote MAC address is learned.
It is also the static tunnel used to reach the MAC address.
Figure 6 Local MAC address learning
Figure 7 Remote MAC address learning
There are two deployment options. Option 1 supported from day one of the release and Option 2 as a
future choice.
Figure 8 shows the static vxlan configuration of the Dell EMC data center switches. The sample
configuration captures only one vlan (vlan 30) but it shows a single tunnel with a single vni profile
mapping to all three VNIs (10,20,3). The configuration would still call for vlans 10 and 20 to be configured
on both switches.
A Dell EMC VXLAN Technical White Paper 21
Figure 8 Current Dell EMC Hardware-Based VTEP.
Dell EMC’s static VXLAN configuration is divided into 5 short steps:
Step 1 – Create a static VXLAN instance
Step 2 – Create a VNI profile
Step 3 – Associate a VNID to the VNI profile
Step 4 – Associate a remote VTEP to the VNID
Step 5 – Associate the VNID to a VLAN
Caveats
There are some guidelines to follow when deploying static vxlan. Table 3 describes these guidelines.
Table 3 Dell EMC Static VXLAN current guidelines
Limitations/Guidelines
 No stacking or VLT supported
 One vxlan instance supported
 No Layer 3 over VXLAN
 No SNMP or REST API supported
 4,000 VNIs
 No Load balancing
 802.1p QoS marking preservation not supported over VXLAN tunnel
A Dell EMC VXLAN Technical White Paper 22
Each deployment has its own set of advantages and disadvantages (see Table 4).
Table 4 Dell EMC Hardware-Based VTEP with Controller vs. without Controller comparison
Dell EMC HW
VTEP
Advantage Dis-advantage
w/ controller  Dynamic VTEP tunnels
configurations
 Minimal manual configuration
needed
 Feature maturity
 Large implementation
 Requires additional
components, i.e nvp
controller, software, protocol
 Orchestration vendors
proprietary implementations
Static VXLAN
 Straight forward, no additional
components needed such as a
controller, manager, or
communication protocol.
 Simple tunnel implementation
 Small/medium size
implementation
 Requires manual
configuration for each VTEP
tunnel
 Potential configuration errors
 Potential for excessive
flooding.
 Feature maturity
Conclusion
VXLAN builds on the traditional and well understood 802.1Q VLAN technology to address the challenges
found in today’s data center.
Before VXLAN, organizations were limited to building isolated/dedicated infrastructures where virtual
environments and physical environments could only communicate with their respective counterparts.
Unfortunately the typical organization’s business infrastructure runs on a mixed set of applications -
virtualized and physical - and therefore a solution was needed.
Being able to bridge the connectivity gap between the ubiquitous virtual and physical environments and
provide data center interconnect (DCI) functionality has become an operational necessity.
Dell EMC Networking with its data center product portfolio supports VXLAN in hardware so customers
can leverage the predictable high-performance and density expected from any large enterprise solution
provider.
With Dell EMC Networking, VXLAN segments whether virtualized or physical can seamlessly connect
with a traditional VLAN segment allowing for multi-tenants to reside in either domain while keeping
flexibility, scalability, and familiarity as part of its solution to our customers.

More Related Content

PDF
At and tmpls
PDF
Scalable midsize data center designs
PDF
Ccnp™ advanced cisco® router
PDF
White Paper: Backup and Recovery of the EMC Greenplum Data Computing Applianc...
 
PDF
Computer networks--introduction computer-networking
PDF
Designing Secure Cisco Data Centers
PPTX
Virtualize with Confidence
PDF
Towards an Open Data Cente with an Interoperable Network (ODIN) Volume 5: WAN...
At and tmpls
Scalable midsize data center designs
Ccnp™ advanced cisco® router
White Paper: Backup and Recovery of the EMC Greenplum Data Computing Applianc...
 
Computer networks--introduction computer-networking
Designing Secure Cisco Data Centers
Virtualize with Confidence
Towards an Open Data Cente with an Interoperable Network (ODIN) Volume 5: WAN...

What's hot (15)

PDF
Brocade-The Ethernet Fabrics-wp
PDF
Give your VDI users the memory they need with server technology from Dell EMC...
PDF
White Paper: Sageza - Strategic Snapshot
 
PDF
router virtualization white paper
PDF
Configuration and Deployment Guide For Memcached on Intel® Architecture
PDF
Design and Deployment using the Cisco Smart Business Architecture (SBA)
DOCX
Chapter 3
PDF
Propalms Centralized Computing Solution Document
PDF
CDM Playbook
PDF
Resume-518
PDF
High Res CIO Review Article
PDF
Extricom white paper_enterprise wlan & the broadband myth
PDF
Practical Guide to Business Continuity & Disaster Recovery
PDF
Rethink Storage: Transform the Data Center with EMC ViPR Software-Defined Sto...
 
PDF
White Paper: New Features in EMC Enginuity 5876 for Mainframe Environments
 
Brocade-The Ethernet Fabrics-wp
Give your VDI users the memory they need with server technology from Dell EMC...
White Paper: Sageza - Strategic Snapshot
 
router virtualization white paper
Configuration and Deployment Guide For Memcached on Intel® Architecture
Design and Deployment using the Cisco Smart Business Architecture (SBA)
Chapter 3
Propalms Centralized Computing Solution Document
CDM Playbook
Resume-518
High Res CIO Review Article
Extricom white paper_enterprise wlan & the broadband myth
Practical Guide to Business Continuity & Disaster Recovery
Rethink Storage: Transform the Data Center with EMC ViPR Software-Defined Sto...
 
White Paper: New Features in EMC Enginuity 5876 for Mainframe Environments
 
Ad

Similar to Dell networking vxlan 2.3 (20)

PDF
Net1674 final emea
PPTX
Netsft2017 day in_life_of_nfv
PDF
PLNOG15: Is there something less complicated than connecting two LAN networks...
PDF
20 - IDNOG03 - Franki Lim (ARISTA) - Overlay Networking with VXLAN
PPTX
Network virtualization
PPTX
NET4933_vDS_Best_Practices_For_NSX_Francois_Tallet_Shahzad_Ali
PPTX
Openstack Neutron Insights
PDF
Network virtualization seminar report
PDF
VMworld 2014: Advanced Topics & Future Directions in Network Virtualization w...
PPTX
Navigating dc architectures tech&amp;sales
PPTX
VXLAN in Data Centers and use cases.pptx
PDF
Network Monitoring in the age of the Cloud
PDF
Virtual networking concepts
PPTX
Network Virtualization in computer networks.pptx
PDF
PLNOG 13: Alexis Dacquay: Architectures for Universal Data Centre Networks, t...
PPTX
Vla ns
PDF
Efficient Data Center Virtualization with QLogic 10GbE Solutions from HP
PPTX
Midokura OpenStack Day Korea Talk: MidoNet Open Source Network Virtualization...
PDF
NFV в сетях операторов связи
PDF
Ccmigration 09186a00807a15d0
Net1674 final emea
Netsft2017 day in_life_of_nfv
PLNOG15: Is there something less complicated than connecting two LAN networks...
20 - IDNOG03 - Franki Lim (ARISTA) - Overlay Networking with VXLAN
Network virtualization
NET4933_vDS_Best_Practices_For_NSX_Francois_Tallet_Shahzad_Ali
Openstack Neutron Insights
Network virtualization seminar report
VMworld 2014: Advanced Topics & Future Directions in Network Virtualization w...
Navigating dc architectures tech&amp;sales
VXLAN in Data Centers and use cases.pptx
Network Monitoring in the age of the Cloud
Virtual networking concepts
Network Virtualization in computer networks.pptx
PLNOG 13: Alexis Dacquay: Architectures for Universal Data Centre Networks, t...
Vla ns
Efficient Data Center Virtualization with QLogic 10GbE Solutions from HP
Midokura OpenStack Day Korea Talk: MidoNet Open Source Network Virtualization...
NFV в сетях операторов связи
Ccmigration 09186a00807a15d0
Ad

Recently uploaded (20)

PDF
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
PDF
Agricultural_Statistics_at_a_Glance_2022_0.pdf
PPTX
Detection-First SIEM: Rule Types, Dashboards, and Threat-Informed Strategy
PDF
Encapsulation_ Review paper, used for researhc scholars
PDF
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
PDF
Review of recent advances in non-invasive hemoglobin estimation
PDF
Advanced methodologies resolving dimensionality complications for autism neur...
PDF
Spectral efficient network and resource selection model in 5G networks
PPTX
Understanding_Digital_Forensics_Presentation.pptx
PDF
Per capita expenditure prediction using model stacking based on satellite ima...
PDF
Empathic Computing: Creating Shared Understanding
PPTX
MYSQL Presentation for SQL database connectivity
PPTX
A Presentation on Artificial Intelligence
PDF
How UI/UX Design Impacts User Retention in Mobile Apps.pdf
PDF
Building Integrated photovoltaic BIPV_UPV.pdf
PDF
Bridging biosciences and deep learning for revolutionary discoveries: a compr...
PPTX
PA Analog/Digital System: The Backbone of Modern Surveillance and Communication
PDF
KodekX | Application Modernization Development
PDF
Approach and Philosophy of On baking technology
PDF
Reach Out and Touch Someone: Haptics and Empathic Computing
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
Agricultural_Statistics_at_a_Glance_2022_0.pdf
Detection-First SIEM: Rule Types, Dashboards, and Threat-Informed Strategy
Encapsulation_ Review paper, used for researhc scholars
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
Review of recent advances in non-invasive hemoglobin estimation
Advanced methodologies resolving dimensionality complications for autism neur...
Spectral efficient network and resource selection model in 5G networks
Understanding_Digital_Forensics_Presentation.pptx
Per capita expenditure prediction using model stacking based on satellite ima...
Empathic Computing: Creating Shared Understanding
MYSQL Presentation for SQL database connectivity
A Presentation on Artificial Intelligence
How UI/UX Design Impacts User Retention in Mobile Apps.pdf
Building Integrated photovoltaic BIPV_UPV.pdf
Bridging biosciences and deep learning for revolutionary discoveries: a compr...
PA Analog/Digital System: The Backbone of Modern Surveillance and Communication
KodekX | Application Modernization Development
Approach and Philosophy of On baking technology
Reach Out and Touch Someone: Haptics and Empathic Computing

Dell networking vxlan 2.3

  • 1. A Dell EMC VXLAN Technical White Paper 1 VXLAN Technical Brief A standard based Data Center Interconnection solution Dell EMC Networking – Data Center Technical Marketing February 2017
  • 2. A Dell EMC VXLAN Technical White Paper 2 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. © Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell and the Dell EMC logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
  • 3. A Dell EMC VXLAN Technical White Paper 3 Table of contents Introduction ...................................................................................................................................................5  Spanning Tree and VLAN Range Limitations .................................................................................5  Multi-tenancy.........................................................................................................................................5  Objective .......................................................................................................................................................6  VXLAN Overview RFC 7348 – Why? ......................................................................................................6  VNI – VXLAN Network Identifier........................................................................................................ 7  VTEP – VXLAN Tunnel End Point .................................................................................................... 7  Multicast ................................................................................................................................................. 7  Layer 3 routing protocol....................................................................................................................... 7  Quality of Service (QoS) ..................................................................................................................... 7  VXLAN Encapsulation and Packet Format............................................................................................. 7  Components of VXLAN Frame Format ............................................................................................8  Feature Comparison – 802.1Q VLAN vs. VXLAN.........................................................................9  VTEP (VXLAN Tunnel Endpoint) Overview..........................................................................................10  Software Based VTEP Gateway.......................................................................................................11  Hardware Based VTEP Gateway.....................................................................................................11  VTEP Packet Forwarding Flow............................................................................................................... 13  Dell EMC VXLAN Architecture................................................................................................................14  Dell EMC VTEP Architecture on the S and Z series Data Center Switches .................................. 15  Deployment Considerations/Guidelines......................................................................................... 17  Dell EMC HW-Based VXLAN Gateway/VTEP Deployment Options ............................................... 17  Option 1: Dell EMC Layer 2 HW-Based VTEP GW with Controller OS 9.10..........................18  Option 2: Dell EMC Layer 2 HW-Based VTEP GW w/out controller (Static VXLAN Tunnels) OS 9.11 ................................................................................................................................................19  BUM Data Packet Handling..............................................................................................................19  Unicast Data Packet Handling .........................................................................................................19  MAC learning.......................................................................................................................................20  Caveats ............................................................................................................................................... 21  Conclusion ..................................................................................................................................................22  Figure 1  VXLAN Frame Format............................................................................................................................ 8  Figure 2  VTEP Function Diagram.......................................................................................................................11  Figure 3  VXLAN Unicast Packet Flow................................................................................................................13 
  • 4. A Dell EMC VXLAN Technical White Paper 4 Figure 4  Dell EMC EMC VXLAN Tunnel End-Point (VTEP) Implementation .............................................16  Figure 5  Current Deployment - Dell EMC Hardware-Based L2 VTEP with NVP controller.................... 18  Figure 6  Local MAC address learning...............................................................................................................20  Figure 7  Remote MAC address learning ..........................................................................................................20  Figure 8  Current Dell EMC Hardware-Based VTEP w/out VLT....................................................................21  Table 1  802.1 Q VLAN and VXLAN Comparison ............................................................................................ 9  Table 2  Software vs. Hardware VTEP comparison........................................................................................12  Table 3  Dell EMC Static VXLAN current guidelines.......................................................................................21  Table 4  Dell EMC Hardware-Based VTEP with Controller vs. without Controller comparison............. 22 
  • 5. A Dell EMC VXLAN Technical White Paper 5 Introduction In the information technology field often when a new technology is created to address a need, an enhancement or complementary technology is created. The best example of this is virtualization (network and resources) in the data center. Prior to virtualization, traditional network segmentation was provided through VLANs (Virtual Local Area Networks) where a set of hosts or a single host would be assigned to a different VLAN ID in order to segment them from each other. If these hosts wanted to communicate with each other; inter-vlan routing would be required. There are inherent shortcomings when using VLANs, such as inefficient network inter-links, spanning tree limitations, physical location of devices, limited number of VLANs (4,094), multi-tenant environments, and ToR (Top of Rack) switch scalability. VLANs have become a limiting factor for IT departments and providers as they look to build efficient and highly scalable multitenant data centers where server virtualization is a key critical component. Spanning Tree and VLAN Range Limitations A typical data center uses a Layer 2 design to facilitate inter-VM communication. This usually results in the presence of the spanning tree protocol to avoid network loops due to duplicate network paths. Spanning tree renders half of the data center network fabric useless since it blocks half of the links to avoid network traffic replication that could cause looping of frames. This increases TCO (Total Cost Ownership), effectively paying for ports that will not be used. In addition to spanning tree, the typical Layer 2 network uses VLANs to provide basic broadcast isolation. The traditional VLAN implementation uses a 12-bit field ID used to separate a large layer 2 domain into separate broadcast domains. This allows for a VLAN ID range of 1 – 4,094. For a small data center environment, this range is usually not an issue; however, with the increased virtualization adoption rate in today’s data center and multi-tenant requirements the traditional VLAN range simply cannot scale. Multi-tenancy It wasn’t long ago when the word cloud computing was just a “buzz” word or a “concept” found in niche areas around service providers willing to try out new bleeding edge technologies. Today, cloud computing is as normal of a concept to most enterprise organizations as the internet is to the average individual. It provides a list of benefits that when properly leveraged becomes a valued asset. One of the primary drivers of cloud computing is the concept of “elasticiticy”. This on-demand elastic provisioning - addition and or removal - of resources for multi-tenant applications makes cloud computing an opportunity for organizations to offload their IT infrastructure to a cloud service provider. Unfortunately, the use of traditional VLANs creates a scalability problem due to the typically large number of tenants supported within the same data center. Since VLANs are used to isolate traffic between the different tenants, limitation of 4,094 VLAN IDs often inadequate. Although Layer 3 networks can sometimes be leveraged to address the VLAN range limitation, it is not atypical to find two different tenants requiring the same Layer 3 ip addressing scheme due to legacy applications, network design requirements, or inherited requirements.
  • 6. A Dell EMC VXLAN Technical White Paper 6 The IEEE has proposed potential initiatives such as TRILL (Transparent Interconnection of Lots of Links), or SPB (Shortest Path Bridging) to address traditional spanning tree shortcomings. However these initiatives have not been widely adopted. What can be done to resolve these issues? Enter VXLAN (Virtual Extensible LAN), a standard officially documented by the IETF as an open standards solution to resolve these shortcomings. Dell EMC with its data center networking product portfolio switches, such as the fixed-configuration Dell EMC S6000 Series, S4048-ON, Z9100-ON, and S6100-ON have been designed for the next-generation data center with hardware-based VXLAN functionality. HW-based VXLAN extend Layer 2 connectivity across a Layer 3 boundary while keeping seamless integration between VXLAN and non-VXLAN environments. Together, these switches form the physical network underlay building blocks of a scalable virtualized and multitenant data center. Objective The objective of this short technical brief document is to provide an overview of VXLAN, its components, and Dell EMC’s architecture and solutions. VXLAN Overview RFC 7348 – Why? If VXLAN is yet another important technology introduced that extends and enhances the traditional 802.1Q VLAN feature set, how does VXLAN add more value or becomes a powerful tool besides enhancing what 802.1Q VLAN provides? The answers to the questions lay in the following problem statement: “How can I as a network administrator or engineer stretch my Layer 2 reach across multiple data centers and not worry about running out of vlan IDs or using duplicate vlan IDs?” VXLAN answers the questions through the use of what is referred as “encapsulation” running over an existing networking infrastructure (Layer 3) to provide a means of stretching a Layer 2 network across different data centers. The RFC defines VXLAN “…as a Layer 2 overlay scheme on a Layer 3 network...” where each overlay is referred as a VXLAN segment and each segment is identified through a 24-bit segment ID referred to as a VNI (VXLAN Network Identifier). This allows potentially up to 16 Million VXLAN segment IDs far greater than the traditional 4,094 VLAN IDs. There are five key elements used within VXLAN as part of its implementation:  VNI (VXLAN Network Identifier)  VTEP (VXLAN Tunnel End Point)  Multicast support – IGMP and PIM  Layer 3 routing protocol – OSPF, BGP, IS-IS  QoS
  • 7. A Dell EMC VXLAN Technical White Paper 7 VNI – VXLAN Network Identifier The VNI is part of the outer header that encapsulates the inner MAC frame sourced by the VM. The VNI is a unique combination of host or VM MAC SOURCE ADDRESS and VXLAN segment ID that identifies a single VM or physical host. It is so unique that it allows for duplicate source MAC addresses to coexist in the same administrative domain. For example, a VM with source MAC_A and VXLAN segment ID 5000 is completely different from a VM or physical host with source MAC_A and VXLAN segment ID 5001. VTEP – VXLAN Tunnel End Point VXLAN as an “encapsulation” scheme is also referred as a “tunneling” scheme and like any tunneling implementation there has to be a starting and end point to the tunnel. To this end VXLAN implements a VTEP in software or hardware. The VTEP uses information from the outer IP header to route or switch traffic from the VMs or physical host. (See Figure 1) Multicast Multicast is needed whenever a VM or host attempts to communicate with another VM or host over Layer 3 (IP) or Layer 2. Typically, if the destination VM or host is in the same subnet the source VM or host will send out an ARP broadcast packet. In a non-VXLAN environment, this frame is simply broadcast across all devices carrying that VLAN. In a VXLAN environment, a broadcast ARP packet is sent to a multicast group address. A VXLAN VNI is mapped to this multicast address group. This mapping is then sent to each VTEP. Once the VTEP has this mapping it is used to provide IGMP membership reports to the upstream switch/router to join/leave the specific multicast group of interest by the VMs or hosts. The infrastructure should be able to meet the multicast requirements, whether it is Layer 3 such as Protocol Independent Multicast – Sparse Mode (PIM-SM) or Layer 2 such as IGMP Snooping. Layer 3 routing protocol As an encapsulation and tunneling scheme, VXLAN is a layer 2 scheme over a layer 3 infrastructure. As a result basic layer 3 routing protocols such as BGP, OSPF, or IS-IS are part of any VXLAN deployment. Quality of Service (QoS) As VXLAN packets traverse the Layer 3 domain carrying with them specific types of traffic/applications and specific level of service, it is imperative that these level of services are not only honored but translated onto the VXLAN IP outer header. This level of service translate as DSCP values where the external physical network infrastructure uses to prioritize the traffic based on the DSCP setting on the IP outer header. VXLAN Encapsulation and Packet Format VXLAN packets are encapsulated over a UDP packet through the use of MAC Address-in-User Datagram Protocol (MAC-in-UDP) and tunneled across different data centers using virtual end point tunnels which will be discussed later on in the document.
  • 8. A Dell EMC VXLAN Technical White Paper 8 The transport protocol used is IP plus UDP. As noted before, VXLAN defines a MAC-in-UDP encapsulation format where the original Layer 2 frame from the source VM has a VXLAN header added and is then encapsulated again in a UDP-IP packet. Figure 1, shows the entire VXLAN Frame format and the related encapsulations over the original Layer 2 frame. Notice how each header is used by the different components as the packet traverses from source to destination. This section breaks down the individual headers that make up the entire VXLAN packet and their respective components. Figure 1 VXLAN Frame Format Components of VXLAN Frame Format Some of the important fields of the VXLAN frame format are: Outer Ethernet Header/Outer MAC Header: The Outer Ethernet Header consists of the following:  Destination Address: Generally, it is a first hop router’s MAC address when the VTEP is on a different address.  Source Address: It is the source MAC address of the router that routes the packet.  VLAN Type and ID: It is optional in a VXLAN implementation and will be designated by an ethertype of 0x8100 and has an associated VLAN ID tag.  Ethertype: It is set to 0x8100 because the payload packet is an IPv4 packet. The initial VXLAN draft does not include an IPv6 implementation, but it is planned for the next draft. Outer IP Header: The Outer IP Header consists of the following components:  Protocol: It is set to 0x11 to indicate that the frame contains a UDP packet.  Source IP: It is the IP address of originating VTEP over which the communication VM is running.  Destination IP: It is the IP address of the target VTEP. This address can be unicast or multicast. A unicast address represents the destination VTEP. A multicast address
  • 9. A Dell EMC VXLAN Technical White Paper 9 represents the VXLAN VNI and the IP multicast group mapping for broadcast communication between VMs or hosts in different domains. Outer UDP Header: The Outer UDP Header consists of the following components:  Source Port: Entropy of the inner frame. The entropy or variability scheme could be based on the inner L2 header or inner L3 header. This value or source port number is to enable a level of uncertainty when it comes to load balancing of VM-to-VM traffic across the VXLAN overlay.  VXLAN Port: IANA-assigned VXLAN Port (4789).  UDP Checksum: The UDP checksum field is transmitted as zero. When a packet is received with a UDP checksum of zero, it is accepted for de-capsulation. VXLAN Header: The VXLAN Header consists of the following components:  VXLAN Flags: Reserved bits (8bits), set to zero except bit 3, the first bit is set to 1 for a valid VNI.  VNI: The 24-bit field that is the VXLAN Network Identifier.  Reserved: A set of fields, 24 bits and 8 bits that are reserved and set to zero. Frame Check Sequence (FCS): The original Ethernet frame’s FCS is not included, but new FCS is generated on the outer Ethernet frame. Feature Comparison – 802.1Q VLAN vs. VXLAN Table 1, shows the enhancements between the typical VLAN and VXLAN feature set. Each of the entries should be taken into consideration whenever deploying VXLAN in the network. Table 1 802.1 Q VLAN and VXLAN Comparison Feature and Scaling 802.1Q VLAN VXLAN Max ID Range 4,000 limited by spanning-tree scaling 16M, limited by the number of multicast groups supported by network devices Packet Size 1.5K or 9K, some devices support up to 12K 50 additional bytes for VXLAN header Multicast Requirements None PIM, SM, DM, or Bi-dir. Many VNIs to a single multicast group mapping supported Routing Support Any Layer 2 or Layer 3 capable device Any Layer 3 or Layer 2 compatible with VMware vShield, vEdge, and any VTEP capable networking device such as the Dell EMC S6000, S4048-ON, and S6100-ON ARP Cache Limits the VMs supported per VLAN Cache size on VMware or VTEP devices limits VMs supported per VNI Duplicate IP across different logical segments N/A Yes
  • 10. A Dell EMC VXLAN Technical White Paper 10 Duplicate MAC address across logical segments N/A Yes Duplicate VLAN IDs across different logical segments N/A Yes VTEP (VXLAN Tunnel Endpoint) Overview So far, we have answered the question of why VXLAN is needed but we have not answered why it is also considered a tunneling scheme? VXLAN as noted before is an encapsulation and tunneling scheme and as such an entity to encapsulate/decapsulate and originate/terminate the tunnel is needed. The encapsulation requirement has been discussed in the VXLAN overview section and now we need to discuss how this encapsulated traffic is handled. Most of today’s data center consists of a mixture of virtualized and non-virtualized compute resources. We also know that these virtualized environments MUST be able to communicate with non-virtualized environments. It is not possible to have a homogeneous data center from the applications, resources, or infrastructure point of view. In a typical data center, a virtualized server has several VMs and they communicate with each other through what is called a vSwitch (virtual Switch). This vSwitch is the first hop for all the VMs and implements the network virtualization part of a virtual environment. Unfortunately, this vSwitch construct does not exist on a non-virtualized server or bare-metal server and therefore establishing any sort of communication between a virtualized and non-virtualized compute resource is not possible unless some type of appliance or gateway device can serve as a bridge between these two different environments. To bridge this gap, the VXLAN RFC introduced the concept of a VXLAN Tunnel Endpoint or VTEP. This entity has two logical interfaces: an uplink and downlink. The uplink interface receives VXLAN frames and acts as the tunnel endpoint with an IP address used for routing VXLAN encapsulated frames. The IP address assigned to this uplink interface is part of the network infrastructure and completely separate from the VMs or tenants IP addressing using the VXLAN fabric. Packets received on the uplink interface are mapped from the VXLAN ID to a VLAN and the Ethernet payload is then sent as a typical 802.1Q Ethernet frame on the downlink to the final destination. As this packet passes through the VTEP a local table is created with the inner MAC SOURCE ADDRESS and VXLAN ID. Packets that arrive at the downlink interface are used to create a VXLAN ID to regular VLAN map.
  • 11. A Dell EMC VXLAN Technical White Paper 11 Figure 2 VTEP Function Diagram There are two types of VTEPs that have been introduced in the industry, a software and hardware based VTEP Gateway: Software Based VTEP Gateway The software based VTEP runs as a separate appliance and it typically runs on a standard x86 hardware with an instance of Open vSwitch. This VTEP is under a controller and it maps physical ports and VLANs on those ports to logical networks. Through this map, VMs that are part of the same logical network can now communicate with the physical device that belongs to the same logical network. This is the approach taken by several overlay architecture such as VMware NSX-v, Midokura, and others. Software based VTEPs are a great solution for fairly moderate amounts of traffic between VMs and physical devices. Hardware Based VTEP Gateway When a full rack of physical servers running database applications need to connect to logical networks containing VMs, ideally these bare metal servers will need a high-density and high-performance switch that could bridge/switch these traffic patterns between the physical servers and logical segments. This is where hardware based VTEPs make sense – migration and interoperability of legacy applications. The hardware based VTEP is no different than the software based VTEP in terms of functionality and controller interaction. A controller which has visibility into the virtualized environment is used to integrate the hardware VTEP and thus creates the gateway functionality required between the virtual and non- virtual environments.
  • 12. A Dell EMC VXLAN Technical White Paper 12 With hardware-based VTEP, the VTEP functionality is implemented in the hardware ASIC resulting in a performance and scalability advantage. There are two types of VTEP functionalities: Layer 2 and Layer 3. As a Layer 2 VTEP gateway, it provides both encapsulation and de-capsulation of legacy or traditional Ethernet and VXLAN packets respectively and allows the stretch of a Layer 2 domain across a Layer 3 domain. Tagged packets configured with a VLAN ID are mapped to a respective VNI entry encapsulated with a VXLAN header. As a Layer 2 VTEP gateway, VMs or hosts from VXLAN segment X cannot communicate with a different VM or host in VXLAN segment Y in order for this communication to take place, a router or Layer 3 device is needed and all routing functions will be performed based on the outer most IP header (see VXLAN Packet Format). As a Layer 3 VTEP gateway, it performs straight VXLAN segment X to VXLAN segment Y routing similar to the traditional inter-VLAN routing providing communication between different VXLAN segments. Contrary to how a Layer 2 VTEP gateway functions (VXLAN to VLAN mapping), a Layer 3 VTEP gateway, performs routing using the VXLAN ID, there is no mapping dependency. VXLAN routing is currently not widely supported with the current silicon. Currently, the most common type of a VTEP GW deployment is as a Layer 2 VTEP gateway with VXLAN routing support to take place with later software releases and newer silicon ASICs. Table 2 Software vs. Hardware VTEP comparison Key Points Software VTEP Hardware VTEP Virtual, physical, or both Virtual Physical Scalability Moderate traffic between VMs Moderate to heavy traffic between VMs and physical servers Orchestration Controller based Controller and non-controller based Performance CPU driven ASIC driven (Line rate)
  • 13. A Dell EMC VXLAN Technical White Paper 13 VTEP Packet Forwarding Flow Figure 3, shows an example of a VXLAN packet forwarding flow. Notice how the outer headers are used at the respective phases as the packet flows from VTEP 1 to VTEP 2. Figure 3 VXLAN Unicast Packet Flow Host-A and Host-B belong to the same VXLAN segment ID 20 and communicate with each other through the VXLAN tunnel created between VTEP-1 and VTEP-2. Step 1 – Host-A sends traffic to Host-B, it creates an Ethernet frame with Host-B’s destination MAC and IP address and sends it towards VTEP-1. Step 2 – VTEP-1 upon receiving this Ethernet frame has a map of Host-B’s MAC address to VTEP-2. VTEP-1 performs the VXLAN encapsulations by adding the respective headers such as VXLAN, UDP, and outer IP headers. Step 3 – Using the information in the outer IP headers, VTEP-1 performs an IP address lookup for VTEP- 2’s address to resolve the next-hop in the transit or IP network. Using the outer MAC header information, VTEP-1 sees the router’s MAC address as the next-hop device. Step 4 – The Ethernet frame is routed towards VTEP-2 based on the outer IP header which has VTEP-2’s IP address as the destination address. Step 5 – After VTEP-2 receives the Ethernet frame, it decapsulates all the headers and forwards the packet to Host-B using the original destination MAC address.
  • 14. A Dell EMC VXLAN Technical White Paper 14 Dell EMC VXLAN Architecture Dell EMC networking’s data center product portfolio provides a solid feature set for the data center. With the Dell EMC S and Z-series product families, Dell EMC supports the hardware-based VXLAN gateway function allowing for the extension of Layer 2 connectivity across a Layer 3 transport network providing predictable high-performance gateway between VXLAN and traditional VLAN environments. Dell EMC’s VXLAN implementation is based on RFC 7348, it uses the existing Layer 2 mechanisms such as flooding and dynamic MAC address learning to create the necessary underlay between VXLAN and traditional VLAN environments. The mechanisms are used to perform the following key functions which are very similar to other vendor’s implementations:  BUM (Broadcast, unknown unicast, and multicast) traffic handling  Discovery/learn remote host/VM MAC addresses and MAC-to-VTEP mappings per VXLAN segment For each VXLAN segment, a map is created between the VXLAN segment and an IP multicast group. This multicast group address is known by all the VTEPs that have knowledge of the VXLAN segment and it is used by all BUM traffic from SA (Source Address) MACs to reach a Multicast Replicator Source (MRS) or service node. It is the service node’s job to direct or service the join request received at the VTEP by the end host or VM. The NVP (Network Virtualization Platform) controller creates a multicast tunnel pointing to the service node or multicast replicator. Each VTEP is programmed by the NVP controller to direct any incoming BUM traffic to this service node through the multicast tunnel. A single packet copy is sent to each VTEP as long as there is interest in joining a particular multicast group from hosts or VMs connected to these VTEPs. Dell EMC’s BUM traffic handling is further enhanced through the use of Bidirectional Forwarding Detection (BFD) to ensure reachability towards the service nodes is guaranteed. In a typical overlay deployment, a cluster of service nodes or MRSs is deployed in order to provide high-redundancy. Once the Dell EMC hardware VTEP establishes a tunnel towards the service node, a BFD session is created and communicated towards the NVP controller. When it comes to VTEP discoveries, there are two approaches: Dynamic and Static. Dell EMC’s implementation uses static configuration of the VTEPs (remote and local) via the NVP controller or manually - via CLI on the device - configuring the remote VTEP when deploying static vxlan tunnels, i.e. no NVP controller used (See Option 2: Dell EMC Layer 2 HW-Based VTEP GW w/out controller (Static VXLAN Tunnels) OS 9.11) . Through the use of a static approach the implementation avoids the need for yet another protocol to discover the VTEPs. As soon as the VTEPs have been configured on the NVP controller or statically configured via CLI on the device (no NVP controller used) and IP reachability has been confirmed, local and remote MAC learning takes place. During the learning phase, the SOURCE ADDRESS MAC address (local and remote) is
  • 15. A Dell EMC VXLAN Technical White Paper 15 mapped to a single VTEP tunnel IP address and logical network/VXLAN segment using a slightly different method. For a remote SOURCE ADDRESS MAC address, when using a controller, the NVP controller creates a remote SOURCE ADDRESS MAC to remote VTEP binding. If there is no controller, and static vxlan is used, remote MAC learning on tunnels is derived from the inner SOURCE ADDRESS MAC of the packet(s) received on the tunnel. For a local SOURCE ADDRESS MAC address, when using a controller, the Dell EMC VTEP switch informs the NVP controller through OVSDB protocol of the SOURCE ADDRESS MAC learned on a specific port or VLAN and if no controller is used, local SOURCE ADDRESS MAC is done when a data packet is received on the access port of the local VTEP device just like any other switch The bindings of the SOURCE ADDRESS MAC(s) to VTEP are propagated by the NVP controller to the VTEPs building a full mesh connectivity infrastructure. See Figure 4, on the specific steps about how the Dell EMC VTEP GW implements this communication. Dell EMC VTEP Architecture on the S and Z series Data Center Switches Dell EMC’s initial VTEP implementation is based on a client to server communication relationship between an NVP (Network Virtualization Platform) and the VTEP. Later on, a different architecture non- controller based is discussed. In Dell EMC’s initial implementation, the NVP entity is the network orchestrator provided by VMware’s NSX-v Platform. The functions provided by the Dell EMC VTEP are the following: 1. Create all the necessary logical networks between the virtualized and non-virtualized environments. 2. Identify and bind <Port, VLAN> to a logical network 3. Maintain the remote and local host MAC bindings to the respective VTEP 4. Establish communication and be managed by the NVP 5. Support standard communication protocol known as Open vSwitch Database (OVSDB) between NVP and itself. The functions provided by the NVP orchestrator are the following: 1. It connects to the NVP gateway/VTEP through a TCP connection which must be configured by the user. 2. It orchestrates a Layer 2 network between the two VTEPs a. Binds Port and VLAN b. Installs VTEP tunnels between the hosts c. Installs both the remote and local VM/host SOURCE ADDRESS MACs on the VTEPs 3. Monitors network database from the VTEPs 4. Pushes the BFD configuration for VXLAN tunnels created towards the service nodes
  • 16. A Dell EMC VXLAN Technical White Paper 16 Figure 4, shows the implementation steps on the VTEP as two hosts initiate to communicate. Figure 4 Dell EMC EMC VXLAN Tunnel End-Point (VTEP) Implementation Step 1 User based VXLAN configuration is passed on to the NVP controller through the OVSDB protocol. The configurations include, <port, vlan, VTEP information with respect to VXLAN configuration>. Dell EMC’s VTEP implementation uses SSL certification between the Dell EMC VTEP and NVP prior to exchanging any information. Step 2 Based on the information received in Step 1, the NVP controller creates a logical network consisting of a logical netwok ID, and VXLAN network ID or segment. The logical network and VXLAN ID/segment is created by the NVP controller administrator, this configuration is not created automatically. Step 3 Bind the port, VLAN, and VTEP information from Step 1, to the logical network(s) created in Step 2. In other words, port X or VLAN Y participating on VXLAN instance Q from VTEP A bind to logical network M. Step 4 Learn local MAC address on VTEP and create tunnel mapped to learned MAC address on the logical network M. All locally learned MACs are advertised to the NVP controller with the VTEP IP address/tunnel as the destination tunnel. Step 5 NVP controller advertises the mapped information to the remote VTEP and the remote VTEP installs this in its forwarding table.
  • 17. A Dell EMC VXLAN Technical White Paper 17 Step 6 NVP controller repeats step 4 for remote VTEP’s host or VM and advertises this information to the Dell EMC HW VTEP where the Dell EMC EMC VTEP installs this entry. The entry information contains the remote SOURCE ADDRESS MAC, remote VTEP IP on which the remote SOURCE ADDRESS MAC has been learned and the logical network. As far as multicast, broadcast, unknown unicast traffic originated at the SOURCE ADDRESS MAC, the NVP controller creates a multicast tunnel pointing to the service node or multicast replicator. Each VTEP is programmed by the NVP controller to direct any incoming BUM traffic to this service node through the multicast tunnel. A single packet copy is sent to each VTEP as long as there is any interest from hosts or VMs connected to these VTEPs. Deployment Considerations/Guidelines Whenever deploying a Dell EMC HW based VTEP Gateway the following considerations or guidelines should be taken: 1. Ensure Dell EMC S6000-ON or S4048-ON are running at least release OS 9.10 or above 2. Ensure IP connectivity is up between the NVP controller and the Dell EMC switch 3. Ensure VMware NSX build is 6.2.2 or later. NSX 6.2.2 supports HW based VTEP GW 4. Configure jumbo frames (Dell EMC MTU 9216) or elephant flow (1600 MTU) frame on all devices creating the underlay. Most networking devices support up to 9216 byte MTU size. Dell EMC HW-Based VXLAN Gateway/VTEP Deployment Options There is no denying that virtualization (compute and network) play a key role in today’s data centers. It has transformed the data center from a sunken expense into a revenue generating asset. It has provided enterprises business agility, competitive advantage, and most importantly efficient usage of resources. Dell EMC’s networking data center product portfolio is designed to deliver on these benefits. The Dell EMC S and Z series family support and function as a hardware-based VXLAN gateway. They seamlessly bridge and connect VXLAN and VLAN segments as a single Layer 2 domain across a Layer 3 infrastructure without incurring any performance degradation. The current hardware supports up to 8,000 unique VNIDs and 511 tunnels. Each tunnel can carry multiple VNIDs. Note: Although VXLAN allows up to 16M unique VNIDs or VXLAN segments, the current silicon supports up to 8,000 unique VNIDs with 16M logical IDs available. The current number of VNIDs supported covers the majority of today’s VXLAN to non-VXLAN environments deployments. The key VXLAN encapsulation and de-capsulation function is hardware-based providing line-rate performance regardless of frame size. Figures 5 and 6 show two key deployments of the hardware-based VTEP configurations from the Dell EMC data center switches.
  • 18. A Dell EMC VXLAN Technical White Paper 18 There are two supported HW-based VTEP GW solutions.  Dynamic using an NVP (Network Virtualization Platform) controller such as VMware’s NSX-v to establish the VTEP tunnels between the different data centers.  Static using manually configured VTEP tunnels between the different data centers. Option 1: Dell EMC Layer 2 HW-Based VTEP GW with Controller OS 9.10 Figure 5 shows the Dell EMC S and Z- series switches working in conjunction with the NVP controller (VMware NSX) to setup dynamic VTEP tunnels between the Dell EMC hardware-based VTEP and the software-based VTEP hypervisor allowing communication between the VMs and the physical server. The dashed lines show the communication between the VTEPs (software or hardware-based) and the NVP controller. On the left side of the topology, the hypervisor VTEP or software based VTEP has dual links to the Dell EMC S6000s. The Dell EMC S6000s are configured in a VLT (Virtual Link Trunk) domain creating a virtual switch towards the software based VTEP hypervisor. This configuration provides redundancy at the ToR, in this case the Dell EMC S6000s. Layer 3 is configured from the hypervisor to the core consisting of a pair of Z9100s or S6000s. Figure 5 Current Deployment - Dell EMC Hardware-Based L2 VTEP with NVP controller
  • 19. A Dell EMC VXLAN Technical White Paper 19 Option 2: Dell EMC Layer 2 HW-Based VTEP GW w/out controller (Static VXLAN Tunnels) OS 9.11 The second deployment type (see Figure 8) shows the Dell EMC S and Z switches as a point-to-point static VXLAN tunnel. In this configuration, there is no controller present and all VTEP tunnels are created manually/statically between the local and remote VTEPs. Although only S6000-ON and S40489-ON are illustrated in each diagram, the entire S and Z series data center switch family supports static vxlan as well. Host or VM SOURCE ADDRESS_MAC learning is identical to a controller based deployment where the SOURCE ADDRESS_MAC is learned as soon as data packet is received at the access port of the VTEP switch. With static VXLAN, address learning is enabled by default. Dell EMC EMC’s static vxlan implementation is efficient and uses simple logical network ID mapping with a specific VTEP tunnel. BUM Data Packet Handling When a packet arrives on an access port with a destination MAC address being either a broadcast, unknown unicast, or multicast (BUM) for which there is no knowledge on the VTEP switch which remote VTEP tunnel to be used for the destination MAC address, the following steps are taken by the local VTEP switch: Step 1 Capture the logical network ID configured on this port or vlan interface on which the packet has been received. Step 2 Learn the SOURCE ADDRESS MAC address on this port or vlan interface. Step 3 Send a unicast copy of the packet to each remote VTEP over the vxlan tunnel which is configured to be part of this logical network. Also send a copy to any local access port that are also part of this logical network. Unicast Data Packet Handling When a data packet arrives on an access port with a unicast destination MAC address, the following steps are taken by the VTEP. Step 1 The logical network ID is derived from the VLAN or port on which the packet has been received Step 2 A lookup is performed in the Layer 2 entry table with the VFI and a unicast destination MAC address.  If the lookup is successful and if the packet is destined to a local access port(s), the native packet will be sent on the access port(s), however, if the packet is destined to a remote VTEP tunnel, the packet is encapsulated with a VXLAN header with a VNID based VFI and the destination IP
  • 20. A Dell EMC VXLAN Technical White Paper 20 address based on the remote VTEP tunnel and is sent out to the next hop along the path to the remote VTEP tunnel  If the lookup is unsuccessful, the same steps that apply to a BUM traffic is performed. MAC learning Local and remote SOURCE ADDRESS MAC learning happen at different places during data forwarding. Local learning takes place when a data packet is received on the access ports. Whereas remote learning takes place at the VTEP tunnel. Learning is enabled by default and it cannot be disabled. The same applies with remote MAC learning which is enabled on the VTEP tunnels. For example, when a data packet is received on an access port, this SOURCE ADDRESS MAC address is mapped to a specific VNID and ingress VTEP tunnel ip address. This piece of information (VNID, SOURCE ADDRESS MAC, and VTEP tunnel ip) is programmed in the switch’s Layer 2 entry or forwarding table. Figures 7 & 8 show an output of both local and remote address learning per vxlan-instance. Note the tunnel ID or ip address of the tunnel. This is the vtep tunnel on which the remote MAC address is learned. It is also the static tunnel used to reach the MAC address. Figure 6 Local MAC address learning Figure 7 Remote MAC address learning There are two deployment options. Option 1 supported from day one of the release and Option 2 as a future choice. Figure 8 shows the static vxlan configuration of the Dell EMC data center switches. The sample configuration captures only one vlan (vlan 30) but it shows a single tunnel with a single vni profile mapping to all three VNIs (10,20,3). The configuration would still call for vlans 10 and 20 to be configured on both switches.
  • 21. A Dell EMC VXLAN Technical White Paper 21 Figure 8 Current Dell EMC Hardware-Based VTEP. Dell EMC’s static VXLAN configuration is divided into 5 short steps: Step 1 – Create a static VXLAN instance Step 2 – Create a VNI profile Step 3 – Associate a VNID to the VNI profile Step 4 – Associate a remote VTEP to the VNID Step 5 – Associate the VNID to a VLAN Caveats There are some guidelines to follow when deploying static vxlan. Table 3 describes these guidelines. Table 3 Dell EMC Static VXLAN current guidelines Limitations/Guidelines  No stacking or VLT supported  One vxlan instance supported  No Layer 3 over VXLAN  No SNMP or REST API supported  4,000 VNIs  No Load balancing  802.1p QoS marking preservation not supported over VXLAN tunnel
  • 22. A Dell EMC VXLAN Technical White Paper 22 Each deployment has its own set of advantages and disadvantages (see Table 4). Table 4 Dell EMC Hardware-Based VTEP with Controller vs. without Controller comparison Dell EMC HW VTEP Advantage Dis-advantage w/ controller  Dynamic VTEP tunnels configurations  Minimal manual configuration needed  Feature maturity  Large implementation  Requires additional components, i.e nvp controller, software, protocol  Orchestration vendors proprietary implementations Static VXLAN  Straight forward, no additional components needed such as a controller, manager, or communication protocol.  Simple tunnel implementation  Small/medium size implementation  Requires manual configuration for each VTEP tunnel  Potential configuration errors  Potential for excessive flooding.  Feature maturity Conclusion VXLAN builds on the traditional and well understood 802.1Q VLAN technology to address the challenges found in today’s data center. Before VXLAN, organizations were limited to building isolated/dedicated infrastructures where virtual environments and physical environments could only communicate with their respective counterparts. Unfortunately the typical organization’s business infrastructure runs on a mixed set of applications - virtualized and physical - and therefore a solution was needed. Being able to bridge the connectivity gap between the ubiquitous virtual and physical environments and provide data center interconnect (DCI) functionality has become an operational necessity. Dell EMC Networking with its data center product portfolio supports VXLAN in hardware so customers can leverage the predictable high-performance and density expected from any large enterprise solution provider. With Dell EMC Networking, VXLAN segments whether virtualized or physical can seamlessly connect with a traditional VLAN segment allowing for multi-tenants to reside in either domain while keeping flexibility, scalability, and familiarity as part of its solution to our customers.