SlideShare a Scribd company logo
Designing Modular, Scalable,
N+1 Redundant UPS
Designing Modular, Scalable, N+1
Redundant Uninterruptible Power
Systems
Timothy Lowe, PhD
Energy Technologies, Inc.
Designing Modular, Scalable,
N+1 Redundant UPS
Development and Application Drivers
Reduced Rack Mounting Space with additional power
Capacity
Light weight but Rugged to Meet Shock and Vibration
Specifications
High Reliability, High MTBF and Low MTBR Cost Effective
in all applications
Modularity With Redundancy
Longer Battery Back up Time
Intelligent Monitoring and Performance History
Ease of Future Application expansion
Flexible Out Put Connector Selection
Designing Modular, Scalable,
N+1 Redundant UPS
Product Goals and Desires
• 2000 Watts in “1U” of Rack Space (1.75 inches)
• Hot Swappable Power and Battery Modules
• N+1 Redundant Capable
• Paralleled Configurations
• Elimination of Output Power Cable Arm Retractors
• Single Phase or Three Phase Configuration
• Ease of Use Display (Single Button Management)
• Input Power Isolation
• 13 Minute Full Load Battery Backup @ 2000 Watts
• High Efficiency and Overload Capable
• Wide Range Voltage Input and Output
• Full Power Capacity at Low and High Temp (-40C to +70C)
• Less Than 40 Pounds
• Flexible Remote Communication (SNMP, WAN, RS232,
RS485)
Designing Modular, Scalable,
N+1 Redundant UPS
Delivered Features
• 2000 Watts, 2500 VA output power per module
• 13 minute run-time per battery module at 2000 W
• Field replaceable, hot swap battery modules
• High reliability & capacity lithium iron phosphate
• Full power operation from -20°C to +60°C
• Power factor correction at AC input
• True on-line double conversion
• Cold start with no AC or DC input connections
• Pure sinusoidal AC output voltage
• Handles both linear and non-linear loads
Designing Modular, Scalable,
N+1 Redundant UPS
Delivered Features
• N+1 redundancy: Increased reliability
• 1-phase or 3-phase AC output configurations
• Up to 32 units can be combined for increased
power rating
• 1U high rack mount unit (1.73” x 19” x 23.0”)
• Light weight: <40 lbs. including battery
• Meets Mil Spec mechanical shock and vibration
standards
• Multiple output connector configurations
• User I/O and Configuration signal ports
Designing Modular, Scalable,
N+1 Redundant UPS
Block Diagram of Power Chain
Designing Modular, Scalable,
N+1 Redundant UPS
Lithium Battery Specifications
Designing Modular, Scalable,
N+1 Redundant UPS
UPS Single Button Flowchart
PUSH to select MAJOR menu items.
TURN to select MINOR menu items.
ETI
Display_R0.0
OUTPUT
Vout = 0.0V
OUTPUT
Iout = 0.0A
OUTPUT
Pout = W
OUTPUT
Pout = VA
INPUT
Vin = 0.0V
BATTERY
Vdc = .0V
MAJOR ALARMS
NONE
MODULE 1/1
REDUN 1/1
INPUT
Iin = 0.0A
INPUT
Pin = W
INPUT
Pin = VA
INPUT
Fin = 0.0HZ
BATTERY
Idc = .0A
BATTERY
Pdc = .
0WBATTERY
Temp = .0C
MINOR ALARMS
NONE
PHASE GRP: A
AC GRP = 1
DC GRP = 1
SER NUMBER
ETI-00000000
Designing Modular, Scalable,
N+1 Redundant UPS
Ultimate Power Source™
Rugged, Compact, Light Weight with
N+1 Parallel Redundancy
Output Power
AC Input Voltage
Options
AC Output
Voltage Options
DC Input Voltage
Options
DC Output
Options
Stand Alone
Battery Run Time
2000 Watts,
2500 VA
80-140 Vrms or
150-265 Vrms
@ 47-65 Hz
115 Vrms or
230 Vrms
50Hz or 60Hz
28 V nominal or
48 V nominal
up to 1250 Watts
of DC total
13 Min. @2000 W
26 Min. @1000 W
Lithium Iron
Phosphate
Front View of Single
1U Module
Designing Modular, Scalable,
N+1 Redundant UPS
Combine up to 32 Units for increased power!
1-phase or 3-phase AC output!
Battery Modules Configuration
Overload
Capabilities
Efficiency
Hot Swappable Battery
Modules
Light Weight Lithium
Parallelable
(up to 32 Units)
1 or 3 Phase AC output
150% Power for 5 sec.
110% w/o degradation
95% Enhanced Power
Conversion
90% Online
Rear View of Single
1U Module
Designing Modular, Scalable,
N+1 Redundant UPS
1U UPS with Several Output Connector Configurations
AC InputTemp Controlled FansSync/Config PortsI/O (RS232/TCPIP)Aux Battery(2) NEMA 5-15
NEMA 5-15 & MS
(2) MS
Designing Modular, Scalable,
N+1 Redundant UPS
1U Battery Expansion Module (BEM)
2 Lithium Iron Phosphate Modules
• Hot swappable Battery Modules
• Same Battery Modules used in the 1U UPS
Designing Modular, Scalable,
N+1 Redundant UPS
Connector Options for 1U BEM
Temp Controlled Fans
Aux Battery
Charger AC Input
(2) Anderson
Connectors
(2) MS connectors. Dual connectors allow BEMs
to be daisy chained for increased backup time
Designing Modular, Scalable,
N+1 Redundant UPS
2U Hot Swappable Paralleling Interface
Backplane Cage Rear View
TCPIP/ HTML
Interface
With MS Connectors,
Other Style Connectors Available
Designing Modular, Scalable,
N+1 Redundant UPS
2U Hot Swappable Paralleling Interface
Fully Assembled in Rack
Rear View
Designing Modular, Scalable,
N+1 Redundant UPS
Hot Swappable Paralleling Interface
Rear View (Backplane Cage not shown)
Hot Swap
Pin Protected
Connectors
Designing Modular, Scalable,
N+1 Redundant UPS
Hot Swappable
Paralleling Interface
Backplane Cage
Floating Self Aligning
Protected Guide Pins
Designing Modular, Scalable,
N+1 Redundant UPS
2U Hot Swappable Paralleling Interface
Backplane Cage Inside View
Floating Self Aligning
Protected Guide Pins
Designing Modular, Scalable,
N+1 Redundant UPS
3U Backplane Cage with
MS Connectors
Designing Modular, Scalable,
N+1 Redundant UPS
3U Hot Swappable
Backplane Cage
Fully Assembled
with MS
Connectors
Designing Modular, Scalable,
N+1 Redundant UPS
Multiple Output connector configurations available to fit
your application (2U Configurations)
Designing Modular, Scalable,
N+1 Redundant UPS
Multiple Output connector configurations available to fit
your application (3U Configurations)
Designing Modular, Scalable,
N+1 Redundant UPS
Ultimate Power Source Mil Spec® Version
1U 2000 Watt Ultra Compact UPS with
1U Battery Extension Module (BEM)
39 Minutes @ 2000 W, 78 Minutes @ 1000 W
Designing Modular, Scalable,
N+1 Redundant UPS
1U 2000 Watt Ultra Compact UPS with
(2) 1U Battery Extension Modules (BEM)
65 Minutes @ 2000 W, 130 Minutes @ 1000 W
Designing Modular, Scalable,
N+1 Redundant UPS
(2) 1U 2000 Watt Ultra Compact UPS with
1U Battery Extension Module (BEM)
26 Minutes @ 4000 W, 52 Minutes @ 2000 W
Designing Modular, Scalable,
N+1 Redundant UPS
(2) 1U 2 kW UPS in parallel in
hot swap configuration
Hot Swappable Paralleling Interface
Front View
Designing Modular, Scalable,
N+1 Redundant UPS
Front Controlled 6 Load PDU
with Status & Alarm Indicators
Rear View with NEMA 5-15 Option
Emergency Power Off
(Press Both)
Choice of
NEMA, IEC or MS
Connectors
Alarm
Reset
UPS 1 or 2
AC Input
Breakers
Battle
Short Load
Control
Switches
Load Status
LEDs Alarm
Status
LEDs
UPS 1 or 2
AC Inputs
Optional Status,
Safety Interlock
and Remote
Control Ports
Designing Modular, Scalable,
N+1 Redundant UPS
PDU, UPS & BEM in Rack
PDU can be mounted Remotely
from UPS and BEM
Designing Modular, Scalable,
N+1 Redundant UPS
1U Power Distribution Unit (PDU) with
1U 2000 Watt Ultra Compact UPS and
1U Battery Extension Module (BEM)
Designing Modular, Scalable,
N+1 Redundant UPS
12 kW, 3 Phase UPS or 6 kW, 3 Phase N+1 UPS
Field Replaceable Modules and Individual Phase Monitoring
(6) 2 kW UPS
Paralleled
together
(13 min backup @ 12 kW)
Power Distribution
Management (PDM)
Allows Easy Field
Replacement
Designing Modular, Scalable,
N+1 Redundant UPS
Tactical Case with 4 kW total UPS power
26 Minutes of Battery Backup @ 4 kW
52 Minutes of Battery Backup @ 2 kW
In a 3U high configuration
Designing Modular, Scalable,
N+1 Redundant UPS
Tactical, Shock Isolated Rack Case with:
1U UPS, 2 kW, 13-30 Min Backup
1U Workstation or Server and
1U Key Board, Touchpad and Display
Designing Modular, Scalable,
N+1 Redundant UPS
Voice: 419.522.4444
Fax: 419.522.4466
Tim Lowe PhD tdlowe@
ruggedsystems.com
For more information go to www.
UltimatePowerSource.com

More Related Content

PPTX
Delta modulon ups
PPTX
Delta UPS – Modulon Family
PDF
Slvt145p
PPTX
Dph series product presentation (1)
PDF
#Solar #Design #TOOL PV System Design Calculations Report at Neotia Universit...
PDF
IRJET- Solar Smart Street Lighting System with Bluetooth Connectivity
PDF
Mitsubishi energy measuring unit ecomonitor plus dienhathe.vn
Delta modulon ups
Delta UPS – Modulon Family
Slvt145p
Dph series product presentation (1)
#Solar #Design #TOOL PV System Design Calculations Report at Neotia Universit...
IRJET- Solar Smart Street Lighting System with Bluetooth Connectivity
Mitsubishi energy measuring unit ecomonitor plus dienhathe.vn

What's hot (18)

PDF
Mitsubishi energy measuring unit eco monitorplus_dienhathe.vn
PPTX
PWM SOLAR CHARGE CONTROLLER ARDUINO NANO
PDF
PC 3-fāžu UPS izvēles iespējas ražošanas uzņēmumu vajadzībām
PPTX
SINGLE CONVERTER SOLAR HIGH MAST LIGHTING SYSTEM
PDF
Batterybox
PDF
Iskra Electrical Measuring Instruments
PDF
Etracer6415BND Etracer4415BND user manual by Ultisolar New Energy
PPT
dsPICDEM MCSM Development Board
PDF
IRJET - Power Generation using Windmill using Movement of Vehicles in Highways
PPTX
LumaNext ppt.11.16.15
DOCX
PDF
Connection and configuration options of FOTO CONTROL 1f invertors
PDF
10027042_USV_Argument_gb
PDF
Power management considerations for u blox 7 - m8 gnss receivers
PPTX
Cell d 600 (evo) product presentation
PDF
Electrical measuring-instruments
PDF
Db Solar V2 09
Mitsubishi energy measuring unit eco monitorplus_dienhathe.vn
PWM SOLAR CHARGE CONTROLLER ARDUINO NANO
PC 3-fāžu UPS izvēles iespējas ražošanas uzņēmumu vajadzībām
SINGLE CONVERTER SOLAR HIGH MAST LIGHTING SYSTEM
Batterybox
Iskra Electrical Measuring Instruments
Etracer6415BND Etracer4415BND user manual by Ultisolar New Energy
dsPICDEM MCSM Development Board
IRJET - Power Generation using Windmill using Movement of Vehicles in Highways
LumaNext ppt.11.16.15
Connection and configuration options of FOTO CONTROL 1f invertors
10027042_USV_Argument_gb
Power management considerations for u blox 7 - m8 gnss receivers
Cell d 600 (evo) product presentation
Electrical measuring-instruments
Db Solar V2 09
Ad

Similar to Designing a Modular, Scalable, Redundant, 1U UPS (20)

PDF
Presentation gamatronic
PPTX
Efore DC backup SYSTEM, Master Portfolio 2016, uninterruptible power supply
PPT
Ultimate Power Source
PPT
9900 Presentation
PPT
Wireless & Energy Harvesting Technologies for Energy Inefficient Buildings
PDF
ECE_468_Report_Sid_AB
PPTX
Efore News, December 2015
PDF
Biến tần yaskawa d1000 - Biến tần hiệu suất cao và tiết kiệm năng lượng.
PDF
Buy Sunmagic Hybrid Solar Inverter at Best Prices Enertech.pdf
PDF
Explore Our Comprehensive Hybrid Solar Systems
PPTX
DFAE_Energy_Dalian_2011.pptx
PDF
DOC049283130 : datasheet power suppy dadd
PDF
3 Phase Hybrid Solar Inverters Hybrid Inverter Bidirectional PCU.pdf
PDF
Folleto informativo de Intellipower
PPT
Ch05_Functional_Decomposition (1).ppt
PPT
Controlled Power Company Overview 2010
PDF
Track 2 session 5 - st dev con 2016-usb type c with pd
PDF
Eaton ats automatic transfer switch ats pwr
PDF
Eaton ATS Automatic Transfer Switch ATS-PWR
Presentation gamatronic
Efore DC backup SYSTEM, Master Portfolio 2016, uninterruptible power supply
Ultimate Power Source
9900 Presentation
Wireless & Energy Harvesting Technologies for Energy Inefficient Buildings
ECE_468_Report_Sid_AB
Efore News, December 2015
Biến tần yaskawa d1000 - Biến tần hiệu suất cao và tiết kiệm năng lượng.
Buy Sunmagic Hybrid Solar Inverter at Best Prices Enertech.pdf
Explore Our Comprehensive Hybrid Solar Systems
DFAE_Energy_Dalian_2011.pptx
DOC049283130 : datasheet power suppy dadd
3 Phase Hybrid Solar Inverters Hybrid Inverter Bidirectional PCU.pdf
Folleto informativo de Intellipower
Ch05_Functional_Decomposition (1).ppt
Controlled Power Company Overview 2010
Track 2 session 5 - st dev con 2016-usb type c with pd
Eaton ats automatic transfer switch ats pwr
Eaton ATS Automatic Transfer Switch ATS-PWR
Ad

More from Energy Technologies, Inc. (ETI) (11)

PPT
Modular Scalable Micro Grid: ICEPAG 2016 Presentation
PPTX
Facilitating a Hydrogen Infrastructure
PPT
Hydrogen Production From 3 Feed Stocks W/O Parasitic Loads
PPT
SNMP: Remote Interface Capabilities
PPT
Tactical Rackmount UPS
PPT
ETI's Supported Programs
PPT
Tactical Shelter Systems
PPT
ETI Company Overview
PPTX
Hybrid and sustainable energy management
Modular Scalable Micro Grid: ICEPAG 2016 Presentation
Facilitating a Hydrogen Infrastructure
Hydrogen Production From 3 Feed Stocks W/O Parasitic Loads
SNMP: Remote Interface Capabilities
Tactical Rackmount UPS
ETI's Supported Programs
Tactical Shelter Systems
ETI Company Overview
Hybrid and sustainable energy management

Recently uploaded (20)

PDF
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
PDF
Empathic Computing: Creating Shared Understanding
PPTX
Digital-Transformation-Roadmap-for-Companies.pptx
PDF
Encapsulation_ Review paper, used for researhc scholars
PDF
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
PDF
Advanced methodologies resolving dimensionality complications for autism neur...
PDF
cuic standard and advanced reporting.pdf
PDF
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
PDF
Per capita expenditure prediction using model stacking based on satellite ima...
PPTX
VMware vSphere Foundation How to Sell Presentation-Ver1.4-2-14-2024.pptx
PDF
Mobile App Security Testing_ A Comprehensive Guide.pdf
PPT
“AI and Expert System Decision Support & Business Intelligence Systems”
PDF
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
PPTX
sap open course for s4hana steps from ECC to s4
PPTX
Programs and apps: productivity, graphics, security and other tools
PDF
Diabetes mellitus diagnosis method based random forest with bat algorithm
PDF
MIND Revenue Release Quarter 2 2025 Press Release
PDF
7 ChatGPT Prompts to Help You Define Your Ideal Customer Profile.pdf
PDF
Dropbox Q2 2025 Financial Results & Investor Presentation
PDF
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
Empathic Computing: Creating Shared Understanding
Digital-Transformation-Roadmap-for-Companies.pptx
Encapsulation_ Review paper, used for researhc scholars
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
Advanced methodologies resolving dimensionality complications for autism neur...
cuic standard and advanced reporting.pdf
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
Per capita expenditure prediction using model stacking based on satellite ima...
VMware vSphere Foundation How to Sell Presentation-Ver1.4-2-14-2024.pptx
Mobile App Security Testing_ A Comprehensive Guide.pdf
“AI and Expert System Decision Support & Business Intelligence Systems”
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
sap open course for s4hana steps from ECC to s4
Programs and apps: productivity, graphics, security and other tools
Diabetes mellitus diagnosis method based random forest with bat algorithm
MIND Revenue Release Quarter 2 2025 Press Release
7 ChatGPT Prompts to Help You Define Your Ideal Customer Profile.pdf
Dropbox Q2 2025 Financial Results & Investor Presentation
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton

Designing a Modular, Scalable, Redundant, 1U UPS

  • 1. Designing Modular, Scalable, N+1 Redundant UPS Designing Modular, Scalable, N+1 Redundant Uninterruptible Power Systems Timothy Lowe, PhD Energy Technologies, Inc.
  • 2. Designing Modular, Scalable, N+1 Redundant UPS Development and Application Drivers Reduced Rack Mounting Space with additional power Capacity Light weight but Rugged to Meet Shock and Vibration Specifications High Reliability, High MTBF and Low MTBR Cost Effective in all applications Modularity With Redundancy Longer Battery Back up Time Intelligent Monitoring and Performance History Ease of Future Application expansion Flexible Out Put Connector Selection
  • 3. Designing Modular, Scalable, N+1 Redundant UPS Product Goals and Desires • 2000 Watts in “1U” of Rack Space (1.75 inches) • Hot Swappable Power and Battery Modules • N+1 Redundant Capable • Paralleled Configurations • Elimination of Output Power Cable Arm Retractors • Single Phase or Three Phase Configuration • Ease of Use Display (Single Button Management) • Input Power Isolation • 13 Minute Full Load Battery Backup @ 2000 Watts • High Efficiency and Overload Capable • Wide Range Voltage Input and Output • Full Power Capacity at Low and High Temp (-40C to +70C) • Less Than 40 Pounds • Flexible Remote Communication (SNMP, WAN, RS232, RS485)
  • 4. Designing Modular, Scalable, N+1 Redundant UPS Delivered Features • 2000 Watts, 2500 VA output power per module • 13 minute run-time per battery module at 2000 W • Field replaceable, hot swap battery modules • High reliability & capacity lithium iron phosphate • Full power operation from -20°C to +60°C • Power factor correction at AC input • True on-line double conversion • Cold start with no AC or DC input connections • Pure sinusoidal AC output voltage • Handles both linear and non-linear loads
  • 5. Designing Modular, Scalable, N+1 Redundant UPS Delivered Features • N+1 redundancy: Increased reliability • 1-phase or 3-phase AC output configurations • Up to 32 units can be combined for increased power rating • 1U high rack mount unit (1.73” x 19” x 23.0”) • Light weight: <40 lbs. including battery • Meets Mil Spec mechanical shock and vibration standards • Multiple output connector configurations • User I/O and Configuration signal ports
  • 6. Designing Modular, Scalable, N+1 Redundant UPS Block Diagram of Power Chain
  • 7. Designing Modular, Scalable, N+1 Redundant UPS Lithium Battery Specifications
  • 8. Designing Modular, Scalable, N+1 Redundant UPS UPS Single Button Flowchart PUSH to select MAJOR menu items. TURN to select MINOR menu items. ETI Display_R0.0 OUTPUT Vout = 0.0V OUTPUT Iout = 0.0A OUTPUT Pout = W OUTPUT Pout = VA INPUT Vin = 0.0V BATTERY Vdc = .0V MAJOR ALARMS NONE MODULE 1/1 REDUN 1/1 INPUT Iin = 0.0A INPUT Pin = W INPUT Pin = VA INPUT Fin = 0.0HZ BATTERY Idc = .0A BATTERY Pdc = . 0WBATTERY Temp = .0C MINOR ALARMS NONE PHASE GRP: A AC GRP = 1 DC GRP = 1 SER NUMBER ETI-00000000
  • 9. Designing Modular, Scalable, N+1 Redundant UPS Ultimate Power Source™ Rugged, Compact, Light Weight with N+1 Parallel Redundancy Output Power AC Input Voltage Options AC Output Voltage Options DC Input Voltage Options DC Output Options Stand Alone Battery Run Time 2000 Watts, 2500 VA 80-140 Vrms or 150-265 Vrms @ 47-65 Hz 115 Vrms or 230 Vrms 50Hz or 60Hz 28 V nominal or 48 V nominal up to 1250 Watts of DC total 13 Min. @2000 W 26 Min. @1000 W Lithium Iron Phosphate Front View of Single 1U Module
  • 10. Designing Modular, Scalable, N+1 Redundant UPS Combine up to 32 Units for increased power! 1-phase or 3-phase AC output! Battery Modules Configuration Overload Capabilities Efficiency Hot Swappable Battery Modules Light Weight Lithium Parallelable (up to 32 Units) 1 or 3 Phase AC output 150% Power for 5 sec. 110% w/o degradation 95% Enhanced Power Conversion 90% Online Rear View of Single 1U Module
  • 11. Designing Modular, Scalable, N+1 Redundant UPS 1U UPS with Several Output Connector Configurations AC InputTemp Controlled FansSync/Config PortsI/O (RS232/TCPIP)Aux Battery(2) NEMA 5-15 NEMA 5-15 & MS (2) MS
  • 12. Designing Modular, Scalable, N+1 Redundant UPS 1U Battery Expansion Module (BEM) 2 Lithium Iron Phosphate Modules • Hot swappable Battery Modules • Same Battery Modules used in the 1U UPS
  • 13. Designing Modular, Scalable, N+1 Redundant UPS Connector Options for 1U BEM Temp Controlled Fans Aux Battery Charger AC Input (2) Anderson Connectors (2) MS connectors. Dual connectors allow BEMs to be daisy chained for increased backup time
  • 14. Designing Modular, Scalable, N+1 Redundant UPS 2U Hot Swappable Paralleling Interface Backplane Cage Rear View TCPIP/ HTML Interface With MS Connectors, Other Style Connectors Available
  • 15. Designing Modular, Scalable, N+1 Redundant UPS 2U Hot Swappable Paralleling Interface Fully Assembled in Rack Rear View
  • 16. Designing Modular, Scalable, N+1 Redundant UPS Hot Swappable Paralleling Interface Rear View (Backplane Cage not shown) Hot Swap Pin Protected Connectors
  • 17. Designing Modular, Scalable, N+1 Redundant UPS Hot Swappable Paralleling Interface Backplane Cage Floating Self Aligning Protected Guide Pins
  • 18. Designing Modular, Scalable, N+1 Redundant UPS 2U Hot Swappable Paralleling Interface Backplane Cage Inside View Floating Self Aligning Protected Guide Pins
  • 19. Designing Modular, Scalable, N+1 Redundant UPS 3U Backplane Cage with MS Connectors
  • 20. Designing Modular, Scalable, N+1 Redundant UPS 3U Hot Swappable Backplane Cage Fully Assembled with MS Connectors
  • 21. Designing Modular, Scalable, N+1 Redundant UPS Multiple Output connector configurations available to fit your application (2U Configurations)
  • 22. Designing Modular, Scalable, N+1 Redundant UPS Multiple Output connector configurations available to fit your application (3U Configurations)
  • 23. Designing Modular, Scalable, N+1 Redundant UPS Ultimate Power Source Mil Spec® Version 1U 2000 Watt Ultra Compact UPS with 1U Battery Extension Module (BEM) 39 Minutes @ 2000 W, 78 Minutes @ 1000 W
  • 24. Designing Modular, Scalable, N+1 Redundant UPS 1U 2000 Watt Ultra Compact UPS with (2) 1U Battery Extension Modules (BEM) 65 Minutes @ 2000 W, 130 Minutes @ 1000 W
  • 25. Designing Modular, Scalable, N+1 Redundant UPS (2) 1U 2000 Watt Ultra Compact UPS with 1U Battery Extension Module (BEM) 26 Minutes @ 4000 W, 52 Minutes @ 2000 W
  • 26. Designing Modular, Scalable, N+1 Redundant UPS (2) 1U 2 kW UPS in parallel in hot swap configuration Hot Swappable Paralleling Interface Front View
  • 27. Designing Modular, Scalable, N+1 Redundant UPS Front Controlled 6 Load PDU with Status & Alarm Indicators Rear View with NEMA 5-15 Option Emergency Power Off (Press Both) Choice of NEMA, IEC or MS Connectors Alarm Reset UPS 1 or 2 AC Input Breakers Battle Short Load Control Switches Load Status LEDs Alarm Status LEDs UPS 1 or 2 AC Inputs Optional Status, Safety Interlock and Remote Control Ports
  • 28. Designing Modular, Scalable, N+1 Redundant UPS PDU, UPS & BEM in Rack PDU can be mounted Remotely from UPS and BEM
  • 29. Designing Modular, Scalable, N+1 Redundant UPS 1U Power Distribution Unit (PDU) with 1U 2000 Watt Ultra Compact UPS and 1U Battery Extension Module (BEM)
  • 30. Designing Modular, Scalable, N+1 Redundant UPS 12 kW, 3 Phase UPS or 6 kW, 3 Phase N+1 UPS Field Replaceable Modules and Individual Phase Monitoring (6) 2 kW UPS Paralleled together (13 min backup @ 12 kW) Power Distribution Management (PDM) Allows Easy Field Replacement
  • 31. Designing Modular, Scalable, N+1 Redundant UPS Tactical Case with 4 kW total UPS power 26 Minutes of Battery Backup @ 4 kW 52 Minutes of Battery Backup @ 2 kW In a 3U high configuration
  • 32. Designing Modular, Scalable, N+1 Redundant UPS Tactical, Shock Isolated Rack Case with: 1U UPS, 2 kW, 13-30 Min Backup 1U Workstation or Server and 1U Key Board, Touchpad and Display
  • 33. Designing Modular, Scalable, N+1 Redundant UPS Voice: 419.522.4444 Fax: 419.522.4466 Tim Lowe PhD tdlowe@ ruggedsystems.com For more information go to www. UltimatePowerSource.com